EXTRACTIONFORCEPS

210101SS210101NB

210101NG

210102SS210102NB

210102NG

210103SS

210103NG

210104SS210104NB

210104NG

210105SS210105NB

210105NG

210106SS210106NB

210106NG

210107SS210107NB

210107NG

210108SS210108NB

210108NG

210103NB

Extraction Forceps No. 1(For upper centrals, canines and roots)

Extraction Forceps No. 2(For upper laterals)

Extraction Forceps No. 7(For upper premolars and roots)

Extraction Forceps No. 29(For upper roots)

Extraction Forceps No. 29S(For upper roots; small beak)

Extraction Forceps No. 30(For upper premolars and roots)

Extraction Forceps No. 44N(For upper roots; narrow beak)

Extraction Forceps No. 107(For upper canines)

210109SS210109NB

210109NG

210110SS210110NB

210110NG

210111SS

210111NG

210112SS210112NB

210112NG

210113SS210113NB

210113NG

210114SS210114NB

210114NG

210115SS210115NB

210115NG

210116SS210116NB

210116NG

210111NB

Extraction Forceps No. 113(For upper roots)

Extraction Forceps No. 136(For upper premolars and roots)

Extraction Forceps No. 147(For upper roots)

Extraction Forceps No. 17(Right Side - For upper molars)

Extraction Forceps No. 18(Left Side - For upper molars)

Extraction Forceps No. 19(For upper wisdoms and roots)

Extraction Forceps No. 51(For upper wisdoms; Bayonet)

Extraction Forceps No. 67(For upper wisdoms; Bayonet)

210117SS210117NB

210117NG

210118SS210118NB

210118NG

210119SS

210119NG

210120SS210120NB

210120NG

210121SS210121NB

210121NG

210122SS210122NB

210122NG

210123SS210123NB

210123NG

210124SS210124NB

210124NG

210119NB

Extraction Forceps No. 76(For upper roots)

Extraction Forceps No. 76N(For small upper roots; narrow beak)

Extraction Forceps No. 76S(For upper roots; small beak)

Extraction Forceps No. 89(Right Side - for upper molars; UpperCowhorn)

Extraction Forceps No. 90(Left Side - for upper molars; UpperCowhorn)

Extraction Forceps No. 94(Right Side - for upper molars)

Extraction Forceps No. 95(Left Side - for upper molars)

Extraction Forceps No. 101(For upper molars and roots)

210125SS210125NB

210125NG

210126SS210126NB

210126NG

210127SS

210127NG

210128SS210128NB

210128NG

210129SS210129NB

210129NG

210130SS210130NB

210130NG

210131SS210131NB

210131NG

210132SS210132NB

210132NG

210127NB

Extraction Forceps No. 13(For lower premolars)

Extraction Forceps No. 74(For lower anteriors and roots)

Extraction Forceps No. 74N(For small lower anteriors and roots;narrow beak)

Extraction Forceps No. 75(For lower premolars)

Extraction Forceps No. 137(For lower centrals and roots)

Extraction Forceps No. 22(For lower molars; Hawk’s bill)

Extraction Forceps No. 73(For lower molars; Hawk’s bill)

Extraction Forceps No. 73S(For lower molars; Hawk’s bill; Smallbeak)

210133SS210133NB

210133NG

210134SS210134NB

210134NG

210135SS

210135NG

210136SS210136NB

210136NG

210137SS210137NB

210137NG

210138SS210138NB

210138NG

210139SS210139NB

210139NG

210140SS210140NB

210140NG

210135NB

Extraction Forceps No. 79(For lower wisdoms)

Extraction Forceps No. 86(For lower molars; Cowhorn)

Extraction Forceps No. 87(For lower molars; Cowhorn)

Extraction Forceps No. 37(Children’s upper incisors and canines)

Extraction Forceps No. 138(Children’s upper anteriors, premolarsand roots)

Extraction Forceps No. 163(Children’s upper anteriors)

Extraction Forceps No. 39(Children’s upper molars)

Extraction Forceps No. 157(Children’s upper molars)

210141SS210141NB

210141NG

210142SS210142NB

210142NG

210143SS

210143NG

210144SS210144NB

210144NG

210145SS210145NB

210145NG

210146SS210146NB

210146NG

210147SS210147NB

210147NG

210143NB

Extraction Forceps No. 158(For children’s upper molar)

Extraction Forceps No. 159(For children’s upper premolars)

Extraction Forceps No. 123(For children’s lower anteriors, premolarsand roots)

Extraction Forceps No. 162(For children’s lower anteriors and roots)

Extraction Forceps No. 160(For children’s lower molars; Hawk’s bill)

Extraction Forceps No. 161(For children’s lower molars; Hawk’s bill)

Extraction Forceps No. 33

Cleaning: Clean and remove all debris immediately afteruse. Use an enzymatic cleaning solution in an ultrasoniccleaner to clean instruments. Your ultrasonic solutionshould be changed daily. Hinged instruments should becleaned and sterilized in the open position. Discolorationand oxidation may occur if instruments are improperlycleanecleaned. To increase the life of your instruments, cleanthem well. Use detergents and disinfectants suitable foruse with medical and/or dental instruments.

Lubrication: To increase the life of your instruments,routine lubrication is recommended. Prior to sterilization,lubricate instruments. This should be done on daily basisor at least weekly. Use only lubricants designed forprecision hinged instruments. If using a dry heat sterilizer,be sure to use a lubricant that is compatible with theopeoperating temperatures of your dry heat unit.

Sharpening: Regular sharpening to your cutters willincrease its service life, and its ability to cut more effect-ively. Frequency of sharpening depends on the frequencyof use, as well as, the types and diameters of wires onwhich the cutter is being used. Check cutters frequentlyto assess if sharpening is needed.

Sterilising: Instruments should be in the open positionwhen sterilised. The most efficient method is steamautoclave. Anaqa Range of instruments is actuallydesigned for use with steam autoclave as well asEthylene Oxide (EtO) sterilisation. Steam autoclaves willnot dull cutters. Other types of sterilising methods includechemical chemical vapour or dry heat. Using cold sterilants is notrecommended. If used, they can chemically attack yourinstruments.

Corrosion: Anaqa range of instruments is very resistantto corrosion. You can prevent corrosion problems byproperly following all manufacturer’s’ recommendations.Discoloration may appear that may not be corrosion.Organic materials that remain can give the appearanceof corrosion and be mistaken for rust.AAn Orange/Brown stain is usually a phosphate layercaused by water sources, cleaning detergents, sterilisationsolutions. Black stain is usually acid reaction causedby detergents.Dark brown stain usually caused by dried blood residues.Bluish / black stain usually is plating caused by autoclavecleaning material.NeNever mix a corroded instrument with new instrumentsas oxidation may be spread to new instruments. It isrecommended that corroded instrument be discardedor replaced.

Maintenance and Care: It is extremely important tofollow proper handling, care and sterilization methodsto ensure proper instruments function and improve theinstrument life. Avoid tap water during the cleaningand sterilization of instruments. Tap water containshigh levels of minerals that can cause instrumentdisdiscoloration and corrosion. Tap water can also neutralizerust inhibiting and lubricating solution. Always usepuried, distilled water in ultrasonic cleaning and autoclave sterilization units. It is also recommended touse a no-rinse ultrasonic solution that contains both a rust inhibitor and a lubricant prior to sterilization andfollow the manufacturer’s exact solution measurements.

Do no leave instruments in the ultrasonic solution aftercycle is complete, remove immediately and dry completely.Autoclaves contain high levels of moisture and can bedamaging if not functioning properly. Instrumenthandling is also important. Make sure instruments aredry before sterilization, keep jaws open, and do notooverload trays. When cycle is complete, remove instruments immediately after cooling. Always check that joints and tips are moisture free or corrosion canoccur. Lubricate with silicone-based lubricant beforestorage.

Corrosion Prevention: Corrosion can be an issue with anystainless steel instrument. Stainless steel requires Oxygento form a protective chromium oxide surface layer, whichprotects against corrosion. Water droplets, organic residueand bonding agents left on the instruments preventoxygen contact with the surface of instrument andpprotective layer of chromium oxide will not form. It is recommended• Instruments should be thoroughly cleaned of all residual matter prior to sterilization.• All instruments should be sterilized in their open position.• All instruments should be thoroughly air or towel dried taking special care in the joint areas and crevices.•• Instruments that have corrosion should never besterilised with non-corroded instruments as the ironoxide on the corroded instrument can transfer to thenon-corroded instruments permanently.

ISFY guarantees against defects in materials and manufacturing. If yourAnaqa instruments should fail or are damaged due to a manufacturingor workmanship defect, we will repair or replace the product withoutquibble or charge once the faulty product is returned with proof ofpurchase.

Please note that this guarantee does not cover damage caused byaaccident, improper care, misuse, alterations to the Anaqa extractioninstruments or user negligence.

Anaqa extraction instruments should be disinfected following the processingguidelines provided. This guarantee does not cover damages which arisebecause these guidelines have not been followed.

ISFY reserves the right to decide whether an instrument is to be repairedor replaced. Where instruments require sharpening, this is considered routine maintenance with normal use and is not covered by any guarantee.

ISFY LtdI-Centre, Oakham Business Park

Hamilton WayManseld

NottinghamshireNG18 5BR UKUK

Tel: +44 (0)115 786 7111Email: [email protected]: www.isfy.co.uk

ISFY manufactures high quality, durable single and reuseablesurgical instruments. We also manufacture equipment toclients’ exacting specications. We are serious about standards, and for that reason we havesourced the very best materials, machinery and processes fromacacross the globe. For example, we use steel from Japan andtungsten carbide tips from the UK, for our premium Anaqa range. We also invest in the very best people – from the highly skilledand experienced teams that manufacture our equipment, to themanagement team of the company, who between them have awealth of experience within the industry.  We will never compromise on quality, which is why we offermarket-leading warranties on our products – up to FIVE yearson our Anaqa range. Service is at the heart of everythingwe do. We pride ourselves on our exibility and personal touch. We are constantly looking to improve our processes and explore thellatest technologies, materials and techniques to generate whatwe call “quality through innovation”.