EWWD 380-C11 BJYNN. EWWD 380-C11 BJYNN. Water Cooled Chiller 369 kW ÷ 1050 kW Single Screw Compressor. TABLE OF CONTENT. Unit position into the range Operating Limits Compressor features Refrigerant Circuit Flooded evaporator Refrigerant level control Control & remote control - PowerPoint PPT PresentationTRANSCRIPT
EWWD380-C11BJYNN
2Apr 21, 2023
Water Cooled Chiller
369 kW ÷ 1050 kW
Single Screw Compressor
EWWD380-C11BJYNN
3Apr 21, 2023
TABLE OF CONTENT
A. Unit position into the range
B. Operating Limits
C. Compressor features
D. Refrigerant Circuit
E. Flooded evaporator
F. Refrigerant level control
G. Control & remote control
H. Unit delivery
I. Options summary
A. Options as standard
B. Options on request
4Apr 21, 2023
EWWD-BJYNN: unit efficiency level
C11C10900
850750
550
460380
5
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
6
200 300 400 500 600 700 800 900 1000 1100 1200
kW
EE
R
A. UNIT POSITION INTO THE RANGE (1/2)
5Apr 21, 2023
EWWD-BJYNN : cooling range
kW cooling @ Evap. 12/7°C - Cond. 30/35°C
200 400 600 800 1000 1200
kW cooling @ Evap. 12/7°C - Cond. 30/35°C
2 Compressors1 Compressor
A. UNIT POSITION INTO THE RANGE (2/2)
Link back
6Apr 21, 2023
B. OPERATING LIMITS
Max evaporator leaving water temperature °C 15Min evaporator leaving water temperature (without glycol) °C 3Min evaporator leaving water temperature (with glycol) °C -8Max condenser leaving water temperature °C 50
Link back
7Apr 21, 2023
EWWD-BJYNN – Single Screw Compressor
“ Frame4 ” single screw compressor
naturally axial balanced loads
naturally radial balanced loads
2 specular compression cycles
infinitely variable cooling capacity control
external oil separator
direct driven screw (no gear)
6 electrical terminals for Y-D as standard
fully semi-hermetic design
composite material on gate rotors
suctioncompressiondischarge
C. COMPRESSOR FEATURES (1/3)
8Apr 21, 2023
EWWD-BJYNN – Single Screw Compressor
“ Frame4 ”radial balancing axial balancing
Composite material (carbon base composition) to improve compressor reliability and energy performances
Stepless slide valve (oil controlled) to change compressor capacity to match exactly the plant thermal request
better chilled water stability
C. COMPRESSOR FEATURES (2/3)
9Apr 21, 2023
EWWD-BJYNN – Single Screw Compressor
“ Frame4 ”
Six electrical terminals to allow as standard a star-delta (Y-D) compressor start
Fully semi-hermetic design to allow ordinary maintenance and to replace easily each component if necessary
External oversized oil separator for the highest efficiency (99.985%) requested by flooded heat exchanger.
C. COMPRESSOR FEATURES (3/3)
Link back
10Apr 21, 2023
EWWD-BJYNN – P&ID. REFRIGERANT CIRCUIT
Link back
11Apr 21, 2023
EWWD-BJYNN – Flooded evaporator
McQuay engineered and manufactured flooded evaporator (with refrigerant in shell and water inside the tubes) for high performance. Same centrifugal chillers technology.
Replaceable water tubes internally rifled and externally enhanced copper, mechanically bonded to steel tube sheets
Two compressors on the same flooded evaporator to increase part load efficiency.
PART LOAD PERFORMANCE ARI std
0
1
2
3
4
5
6
7
8
9
10
0 10 20 30 40 50 60 70 80 90 100COOLING CAPACITY %
CO
P
E. FLOODED EVAPORATOR
Link back
12Apr 21, 2023
EWWD-BJYNN – Servo controlled refrigerant level regulator
Servo controlled liquid regulator is operating by a pilot float valve that is leading the open/close sequence of the main exp. valve to optimize refrigerant feed to the evaporator in all the working conditions
F. REFRIGERANT LEVEL CONTROL
Link back
13Apr 21, 2023
EWWD-BJYNN – Microprocessor Control “Microtech II C Plus”
Motherboard with microprocessors
Unit Controller fully programmed and engineered by McQuay on Carel hardware
P.I.D. logic (proportional, integrative, derivative)
Compressor regulated according leaving evaporator water temperature (LEWT) to match customer set-point within ± 0.2°C
Easy visual interface with 4 rows and 20 characters display and 15 keypad
G. CONTROL & REMOTE CONTROL (1/3)
14Apr 21, 2023
High value control functions implemented as standard into the logic
Link back options summary
EWWD-BJYNN – Microprocessor Control “Microtech II C Plus”
G. CONTROL & REMOTE CONTROL (2/3)
15Apr 21, 2023
Easy integration into building automation systems via separate digital connection for unit start/stop, status, general fault and 4-20 mA signals for chilled water setpoint reset and demand limiting; Communications capabilities for remote monitoring, changing of setpoint, trend logging, alarm and event detection, via a compatible IBM-PC with Daikin PlantVisor 1.0 software; BMS communication capability via Modbus, BacNet, LonWorks protocol; Remote communications capabilities via modem/GSM (up to 8 chillers with Gateway Modem); Compatibility with Daikin CSC II (Chiller Sequencing Control)
Link back options summary
EWWD-BJYNN – Microprocessor Control “Microtech II C Plus”
G. CONTROL & REMOTE CONTROL (3/3)
Link back table of content
16Apr 21, 2023
EWWD-BJYNN – Unit delivery, moving and lifting
Unit is delivered EXW (Ex works);
Each unit is tested at full load before shipping;
Unit handling must be according to IOM manual.
Link back
H. UNIT DELIVERY
17Apr 21, 2023
EWWD-BJYNN: OPTIONS SUMMARY
• Standard options– Brine version (OPZH;OPZL)
– Double setpoint
– Thermal relays compressors
– Under/over voltage controller
– Victaulic on condenser
– Flow switch for evaporator
– Setpoint reset and demand limit
– Alarm from external device
– Rubber type antivibration mounts
– Main switch (OP52)
– Electronic Expansion valve (OPEX)
• Available options– Power factor 0.9 (OPPF)
– Suction stop valve (OP12)
– A/V meter (OP57)
– Soft starter (OPSS)
– Cu/Ni heat exchanger
18Apr 21, 2023
1. OPTIONS AS STANDARD (1/2)
FLOW SWITCH – Supplied separately to be wired and installed on the evaporator
water piping (by the customer).
COMPRESSOR THERMAL OVER RELAYS – Safety devices against
compressor motor overloading in addition to the normal protection envisaged by
the electrical windings.
UNDER/OVER VOLTAGE – Phase monitor to control the minimum and maximum
voltage value that the user can set.
ALARM FROM EXTERNAL DEVICE – Microprocessor is able to receive an
alarm signal from an external device (pump etc…). User can decide if this alarm
signal will stop or not the unit
Link back options summary
19Apr 21, 2023
RUBBER TYPE ANTIVIBRATION MOUNTS – Supplied separately, these are
positionned under the base of the unit for “floor installation”
OPEX – Electronic expansion valve – It proposes features that makes it unique:
short openning and closing time, high resolution, positive shut-off function to
eliminate use of additional solenoid valve, highly linear flow capacity, continous
modulation of mass flow without stress in the refrigerant circuit and corrosion
resistance stainless steel body
1. OPTIONS AS STANDARD (2/2)
Link back options summary
20Apr 21, 2023
2. OPTIONS ON REQUESTOPSS Soft start – Electronic starting device to reduce starting current. An overload
protection is included (no need of compressors thermal relays).
OP12 - Suction line shut off valve – Suction shut-off valve installed on the suction port of the compressor to facilitate maintenance operation.
OPLN Sound proof cabinet – Made of sheet metal and internally insulated, the sound proof cabinet is around the compressor/s reach the best performance in noise reduction.
OPPF- Capacitor power factor correction - Installed on the electrical control panel to ensure it conforms to the plant rules (Daikin advises maximum 0,9).
OP57- Ammeter and voltmeter – Digital meters of unit drawn amperes and voltage values, installed on the electrical control panel.
Link back options summary