1 Rev. 0.2 BeRex ●website: www.berex.com ●email: [email protected] Specificaons and informaon are subject to change and products may be disconnued without noce. BeRex is a trademark of BeRex. All other trademarks are the property of their respecve owners. © 2015 BeRex Preliminary Manual Evaluaon Kit User’s Manual Digital Variable Gain Amplifier(DVGA) BVA 303/305/518

Upload: buinguyet

Post on 12-May-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

1

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s Manual

Digital Variable Gain Amplifier(DVGA) BVA 303/305/518

2

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

Table of contents

Introduction ……………………………………………………………...………………………………………………….…………….….. 3

Applications Support ………………………………………...……………………………………………………………….….……. 3

Evaluation Kit Contents and Requirements ……………………………………………………………………….……… 3

Kit Contents ………………………………………………………………...…….…….………………………………………………...…. 3

Software Requirements ……………………………………………………………..…………………………………………….……… 3

Hardware Requirements………………………………………………………………………………...……………………...………… 4

MCM BVA303/305/518 Evaluation Board Assembly ……………………………………………...…………..… 5

Overview ………………………………………………………………………………………………...…………………………………... 5

MCM BVA303/305 Evaluation Board Outline showing functional overview...…………………………………………………. 6

DVGA Interface Board V1.0 Hardware Operation ……………………….………………………………………………………...… 7

MCM BVA518 Evaluation Board Outline showing functional overview...…………………………………………………. 8

DVGA Interface Board V3.0 Hardware Operation ……………………….………………………………………………………...… 9

How to set up PUP …………………………………………...……………………….………………………………………………………….. 10

USB Interface Board ………………………………………………………………….…………………………………………….…. 11

USB Interface Board Overview ………………………………………………………………………………………………………… 11

Connection of the USB Interface Board to the Evaluation Board …………………………..…………………………………… 11

USB Driver Installation for windows 8 or 7…………………………………….……………………………………………………… 12

USB Driver Installation for windows XP…………………………………….……………………………………………………… 13

EVK Software Installation ………………………………………………………………………………………….……………..… 16

Using the Application Software Graphical User Interface ………………………………………….…….... 19

Evaluation Board Overview….…………………………………………………….……………………………………………….. 22

Tips for Direct control Serial mode …..……………………………………………………………………………………... 23

Technical Resources …..………………………………………………………………………………………………………………... 24

3

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

Introduction

The BVA303/305/518 is a gain amplifier with enhanced 6-bit RF Digital Step Attenuator(DVGA) designed for use in 3G/4G wireless infrastructure and other high performance RF applications. An inte-grated digital control interface supports both serial and parallel programming of the attenuation, in-cluding the capability to program an initial attenuation state at power-up. Covering a 31.5 dB attenua-tion range in 0.5 dB steps, it maintains high linearity and low power consumption from 30~40MHz through 4 GHz. BVA303/305/518 also features an external negative supply option, and is offered in a 24-lead 4x4 mm QFN package. The BVA303/305/518 Evaluation Kit (EVK) includes the application software and hardware required to control and evaluate the functionality of the DVGA using a PC running the Windows operating system to control the USB interface board

Application support

For any technical inquiries regarding the evaluation kit or software, please visit applications support at

www.Berex.com (fastest response) or call (82)-2-568-2754.

Evaluation Kit Contents and Requirements

Kit Contents

The BVA303/305/518 Evaluation Kit (EVK) includes all of the specific software and hardware required to evaluate the DVGA. Included in the EVK are:

Quantity Description

1 BVA303/305/518 Evaluation RF Board Assembly

1 USB Interface Board Assembly

1 USB 2.0 Type A to Type B Mini Cable

Software Requirements

The application software will need to be installed on a computer with the following minimum require-ments: PC compatible with Windows™ XP, Vista, 7, or 8 Mouse USB port HTML browser with internet access Administrative privileges

4

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

Hardware Requirements

In order to evaluate the DVGA(Digital Variable Gain Amplifier) performance of the evaluation board, the following equipment is required:

DC power supplies and DC cables

Signal Generator

Spectrum Analyzer Vector network analyzer

CAUTION: The BVA303/305/518 DVGA EVK contains components that might be damaged by exposure to voltages in excess of the specified volt-

age, including voltages produced by electrostatic discharges. Handle the board in accordance with procedures for handling static-sensitive compo-nents. Avoid applying excessive voltages to the power supply terminals or signal inputs or outputs.

5

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

MCM BVA303/305/518 Evaluation Board Assembly

Overview

The Evaluation Board is assembled with a BVA303/305/518 DVGA, SP2T mechanical switch (P/S), Paral-lel Programming switches (D1~D6,LE), several headers, and SMA connectors. The P/S switch is used for Parallel or Serial mode selection. The D1~D6,LE switches are used for setting the control bits in Direct Parallel programming mode.

Figure 1. MCM BVA303/305/518 Evaluation Board Assembly

< BVA303/305 > < BVA518 >

6

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

Figure 2. MCM BVA303/305 Evaluation Board Outline Showing Functional Overview

< BVA303/305 RF & Interface(V1.0) Evaluation Board>

“High” in Direct Parallel Mode

"Middle"Set for Latched Parallel/

Serial Mode, Using GUI on PC

“Low” in Direct Parallel Mode

Mini USB Connector port

Power-up Selector Jumper1. PUP1:High, PUP2:High – 31.5dB2. PUP1:High, PUP2:Low – 16dB3. PUP1: Low, PUP2:High – 8dB

4. PUP1: Low, PUP2:Low – 0dB

(refer to datasheet's table 5)

VDD and VDD_DIG Jumper Together

VSS Jumper to GND

Parallel/Serial Mode Selection1. Direction Left(←) is Parellel/Latched Parallel

2. Direction Right(→) is Serial

RF In(DSA Input)RF out(Amp output)

Programming Switches(LE,D1~D6)

Set for PUP “High”

Set for PUP “Low”

1.2.3.4.

Power supply Connector1. VDD(3V)2. VDD_DIG(3V)3. GND4. GND

Port of Direct connect to LE/CLK/DATA1. Data2. LE3. CLK4. GND

1.2.3.4.

7

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

DVGA Interface Board V1.0 Hardware Operation (BVA303/305 Evaluation Board Realease)

1. Verify that all DC power supplies are turned off before proceeding

2. Connect the jumper on JP1, JP2

3. Set jumpers of PUP1 (J7) and PUP2 (J8) to be “HIGH” at upper position and “LOW” at down position

4. Position the P/S switch to Parallel or Serial mode (Left:Parallel & Latched Parallel, Right:Serial)

5. Set the D1~D6 and LE mechanical programming switches on board to support Direct Parallel, Latched Parallel, or Serial mode

a. Serial or Latched Parallel mode(using GUI application software on PC)

- Place D1~D6 and LE at the middle position to support Latched Parallel and Serial modes with

GUI application software and proper position of P/S switch

b. In Direct Parallel mode(Using SP3T switch on Interface board without PC)

- D1~D6 can be set to “HIGH” or “LOW” to manually program the attenuation state while LE is

connected to “HIGH” without using the Mini USB Interface and GUI application software

Table 1. SP3T Switch Descriptions for parallel mode

6. Provide external power supply to the J4 connector (refer to the Operating Ranges table in the datasheet for the voltage range)

a. VDD is the positive power supply with 3.0V typical

b. VDD_DIG is the positive power supply for control signals with 1.8V typical, and it can be connected to VDD with jumper

on JP1 to simplify the test set-up

c. VSS is the external negative power supply with –3.3V typical. To simplify the test set-up, it can also be shorted to GND with

jumper on JP2 to enable using the internal negative voltage generator

Remark : In order to evaluate the DVGA of the evaluation board on parallel or serial mode, You should

connect the USB cable to a PC. And then to supply an External power VDD or VDD_DIG to the evalua-

tion board.

D1 0.5dB

D2 1dB

D3 2dB

D4 4dB

D5 8dB

D6 16dB

LE Latch enable

8

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

Figure 3. MCM 518 Evaluation Board Outline Showing Functional Overview

< BVA518 RF & Interface(V3.0) Evaluation Board>

Mini USB Connector port

Power-up Selector Jumper1. PUP1:High, PUP2:High – 31.5dB2. PUP1:High, PUP2:Low – 16dB3. PUP1: Low, PUP2:High – 8dB

4. PUP1: Low, PUP2:Low – 0dB

(refer to datasheet's table 5)

VDD and VDD_DIG Jumper Together

VSS Jumper to GND

Parallel/Serial Mode Selection1. Direction high(↑) is Parellel/Latched Parallel

2. Direction Low(↓) is Serial

RF In(DSA Input)RF out(Amp output)

Set for PUP “High”

Set for PUP “Low”

1.2.3.4.

Power supply Connector1. VDD(5V)2. VDD_DIG(5V)3. GND4. GND

Option Switch for using Serial or Parallel select

Port of Direct connect to LE/CLK/DATA1. Data2. LE3. CLK4. GND

1.2.3.4.

“High” in Direct Parallel Mode

"Middle"Set for Latched Parallel/

Serial Mode, Using GUI on PC

“Low” in Direct Parallel Mode

Programming Switches(D1~D6,LE)

9

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

1. Verify that all DC power supplies are turned off before proceeding

2. Connect the jumper on JP1, JP2

3. Set jumpers of PUP1 (J7) and PUP2 (J8) to be “HIGH” at upper position and “LOW” at down position

4. Position the P/S switch to Parallel or Serial mode (Upper:Parallel & Latched Parallel, Down:Serial)

5. Set the D1~D6 and LE mechanical programming switches on board to support Direct Parallel, Latched Parallel, or Serial mode

a. Serial or Latched Parallel mode(using GUI application software on PC)

- All of pin on DIP1(option Switch) set to high

<Figure 4. DIP1 Switch setting in case of Serial or Latched Parallel>

- Place D1~D6 and LE at the middle position to support Latched Parallel and Serial modes with

GUI application software and proper position of P/S switch

b. In Direct Parallel mode(Using SP3T switch on Interface board without PC)

- 1pin on DIP1(option Switch) set to high and others pin are setting to down

<Figure 5. DIP1 Switch setting in case of Direct Parallel>

- D1~D6 can be set to “HIGH” or “LOW” to manually program the attenuation state while LE is

connected to “HIGH” without using the Mini USB Interface and GUI application software

6. Provide external power supply to the J4 connector (refer to the Operating Ranges table in the datasheet for the voltage range)

a. VDD is the positive power supply with 3.0V typical

b. VDD_DIG is the positive power supply for control signals with 1.8V typical, and it can be connected to VDD with jumper

on JP1 to simplify the test set-up

c. VSS is the external negative power supply with –3.3V typical. To simplify the test set-up, it can also be shorted to GND with

jumper on JP2 to enable using the internal negative voltage generator

Remark : In order to evaluate the DVGA of the evaluation board on parallel or serial mode, You should

connect the USB cable to a PC. And then to supply an External power VDD or VDD_DIG to the evalua-

tion board.

D1 0.5dB

D2 1dB

D3 2dB

D4 4dB

D5 8dB

D6 16dB

LE Latch enable

DVGA Interface Board V3.0 Hardware Operation (BVA518 Evaluation Board Realease)

Table 1. SP3T Switch Descriptions for

Parallel mode

10

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

HOW to set the PUP 1. Position the Parallel/Serial switch to Parallel mode

2. Set the “LE” Switch to “Low”

3. Set jumpers of PUP1 (J7) and PUP2 (J8) to be “HIGH” at upper position and “LOW” at down position as you need

(refer to Table 2)

Table 2. Parallel PUP Truth Table

4. Provide external power supply (VDD)

P/S LE PUP2 PUP1 Attenuation state

0 0 0 0 Reference Loss

0 0 1 0 8 dB

0 0 0 1 16 dB

0 0 1 1 31.5 dB

0 1 X X Defined by C0.5-C16

11

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

USB Interface Board Overview

A USB interface board (Figure 3) is included in

the Evaluation Kit. This board allows the user to send SPI commands to the device under test by using a PC running the Windows™ operating system. To install the software, extract the zip file to a temporary directory and follow the installation procedure included.

USB Interface Board

Connection of the USB Interface

Board to the Evaluation Board The Evaluation Board and the USB interface board contain the 15 pin D-sub connector. This feature allows the USB interface board (socket) to connect directly to the Evaluation Board (pin) on the front-side as shown in Figure 4.

Figure 6. USB interface board

Figure 7. DVGA USB Interface Board

Connected to the BVA303/305/518 Evaluation

Board for Latched Parallel and Serial

Programming

USB Driver Installation The latest USB interface board drivers are available via Microsoft Windows update. Internet connectivity is required to download the drivers. Connect the USB interface board to the PC and select the Windows Update option to obtain and install the drivers. If the USB board drivers are not installed, it will not be possible to run the program correctly.

A USB interface board (Figure 5) is included in the

Evaluation Kit. This software is available directly from FTDI’s website at http://www.ftdichip.com/Drivers/VCP.htm Recommend : For Windows XP, USB Serial Converter & Port Driver recommend 2.10.00(x86:32-bit, x64:64bit) WHQL Certified file.

Figure 8. USB Driver Installation

< DVGA Interface(V1.0) Evaluation Board> < DVGA Interface(V3.0) Evaluation Board>

12

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

USB Driver Installation for Windows

8 or 7

Figure 10(a-b). USB Serial Converter

Driver

FTDI Driver Installation For Windows 8 and 7, drivers will be installed auto-matically when your computer is connected to the Internet. Alternatively, you may install the drivers from the file web site download (http://www.ftdichip.com/Drivers/VCP.htm) Connect the USB Serial converter to an available USB port, and the “Found New Hardware Wizard” will guide you through the installation process. When prompted to connect to Windows Updates to search for drivers, select “No, not at this time”, and follow the instructions for installing from the file downloaded Once the drivers are successfully installed, the USB Serial converter will show up in the Windows Device Manager: Under “Ports (COM & LPT)”: labeled as “USB Serial Port (COMx)”, and under “Universal Serial Bus controllers”: labeled as “USB Serial Converter” (Figure 10-b). IMPORTANT NOTES: If it’s the first time you install the driver for

CommFront’s USB to Serial device, you will need to install the driver twice. One is for “USB Serial Converter”, and the other one is for “USB Serial Port”.

DO NOT close the 2nd “Found New Hardware Wiz-ard” window while installing the driver.

Upon completion of driver installations, remember to check the Windows Device Manager to make sure that the drivers are installed properly (Figure 10-a). If the drivers are not installed correctly, there will be a yellow exclamation icon displayed under the “Ports (COM & LPT)” or “USB Serial Bus controllers”, right-click on the yellow exclamation icon and select “Update driver”. Then search for the driver

13

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

connect the USB Serial converter to an available USB

port, the “Found New Hardware Wizard” window will

pop up. Select “No, not this time” and click on the

“Next” button to continue (Figure 11-a)

Figure 11(a-d). USB Serial Converter

Driver Installation for windows XP

Select “Install from a list or specific location

(Advanced)” to install the driver from files

And Click “Next“button

Select “Search for the best driver in these locations”

and check the box of “Include this location in the

search”.

Then Click on the “Browse” button

And browse to the location you unzipped the USB driv-

ers to in the previous step

http://www.ftdichip.com/Drivers/VCP.htm (2.10.00 WHQL Certified file) Windows will install the first driver. (Maybe select FTDIBUS.INF)

USB Driver Installation for Windows

XP

14

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

The wizard will search for the driver and then tell you that a “ USB Serial Converter” was found. Click finish

Figure 11(e-g). USB Serial Converter

Driver Installation for windows XP

After finish the USB Serial Converter Driver. You can find the new hardware wizard pop up window of USB Serial Port.(Figure 11-f) Select “Install from a list or specific location

(Advanced)” to install the driver from CD

And Click “Next“button

Select “Search for the best driver in these locations”

and check the box of “Include this location in the

search”.

Then Click on the “Browse” button

And browse to the location you unzipped the USB driv-

ers to in the previous step

15

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

If Windows gives any warnings, click OK to proceed. (Select Directory to the location you unzipped the USB drivers to in the previous step)

Windows will install the first driver. (Maybe select FTDIPORT.INF) Click NEXT when the installation is complete.

Figure 11(h-l). USB Serial Converter Driv-

er Installation for windows XP

16

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

EVK Software Installation

To install the DVGA evaluation software, unzip the

archive and execute the “setup.exe.”

Figures 12(a-c). Application Software

Installation Procedure

In order to evaluate the BVA303/305/518 performance, the Application Software has to be installed on

your computer.

The USB interface and DVGA application software is compatible with computers running Windows™ XP,

Vista, 7, or 8. This software is available directly from Berex’s website at

http://www.berex.com/Products/Documents/Installers/DVGA%20Evaluation%20Software%

20Installer%20R2.3.1.zip

After the setup.exe file has been executed, a

welcome screen will appear. It is strongly

recommended that all programs be closed prior to

running the install program. Click the “Next>”

button to proceed

17

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

For most users the default install location for the

program files is sufficient. If a different location is

desired, the install program can be directed to

place the program files in an alternate location.

The software is installed for “Everyone” by

default. Once the desired location is selected

click “Next >.”

Figures 12(d-f). Application Software

Installation Procedure

As the software files are installed, a progress

indicator will be displayed. On slower computers,

installation of the software may proceed for a

few moments.

The Confirm Installation is ready to install the

DVGA evaluation software on your computer, then

click “Next>” to proceed with the software

installation.

18

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

Once the evaluation software is installed, click

“Close” to exit.

A new Start Menu item under Peregrine

Semiconductor will appear in the start menu of

your computer. Select “DVGA Evaluation

Software” to launch the GUI.

Figures 12(g). Application Software

Installation Procedure

19

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

Figure 9 displays the DVGA application software graphical user interface (GUI), which has the USB in-

terface board plugged into the computer. If the USB interface board is not connected when the appli-

cation software is launched, the message “No interface board connected! Please connect USB

-SPI Interface #101-0695.” will appear at the bottom of the screen.

In the upper left corner, under the Peregrine Logo there is a drop down menu item to select the part

for evaluation and the part description is right below the part number box.

Using the Application Software Graphical User Interface

Figure 13. DVGA Application Software Graphical User Interface (GUI)

20

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

The DVGA application software GUI supports Latched Parallel and Serial modes, and shows the control

bit waveform at the right side of the GUI when the mode is selected.

The Send button changes functionality based on the control interface mode. Send Latch in Latched Par-

allel mode and Send Signal in Serial mode is provided to resend the programming bits to the device at

the same attenuation state.

Figure 14. Latched Parallel or Serial Mode

Continuous Pattern Loop can be selected to automatically step through each of the attenuation states.

The Attenuation Value box displays the attenuation value the DVGA is currently programmed. The user

can enter the desired attenuation value followed by the “Enter” key to program the DVGA.

21

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

The center of the GUI is the attenuation slide bar that allows the user to quickly select the desired

attenuation. The arrows at the top and bottom can be clicked to increase or decrease attenuation state

at the minimum step size.

22

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

Figure 15. BVA303/305/518 Evaluation Board Schematic

Evaluation Board Overview

23

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

Tips for Direct control Serial mode

DVGA interface board provides an environmental to

test the serial interface by mcu you own.

You can connect between BVAxxx and MCU you own

(Figure 16)

And then If MCU send the signal CLK,DATA,LE,

you will be able to control the BVAxxx like DVGA Inter-

face board using GUI

1. DATA2. LE3. CLK4. GND

Figures 16. DVGA Interface board connect

to Serial interface & Direct control

24

Rev. 0.2

BeRex ●website: www.berex.com ●email: [email protected]

Specifications and information are subject to change and products may be discontinued without notice. BeRex is a trademark of BeRex.

All other trademarks are the property of their respective owners. © 2015 BeRex

Pre

limin

ary

Man

ual

Evaluation Kit User’s manual

BVA303/305/518

Additional technical resources are available for download in the Products section at www.berex.com. These include the Product Specification datasheet, Evaluation Kit schematic and Bill of Materials, Mate-rial Declaration form, and PC-compatible software file. Trademarks are subject to trademark claims.

Technical Resources