(GRMS) is to provide convenience to the guest, enhance the
operator’s management control and provide energy savings.
GRMS is based on an integrated DIN
all the control devices such as relays, dimmers and FCU
control modules. Auxiliary control devices such as wall
mounted control panels, thermostats, DND/MUR
indicator and Key card holders provides the control user
interfaces to the system.
Highlights
n One solution to offer excellent guest experience
n Beautiful aesthetics that blend into any environment
n Highly economical solution with rich functionality
n Reliable technology, designed for guest comfort
n Flexibility to choose from a wide range of choices
n All that luxury, essentially without all that cost
n Simplicity
Integration with Property Management Systems (PMS)an be interfaced with the PMS. It will receive at the minimum the following information from PMS:
n Room rented StatusIt will transmit at minimum the following information to PMS: n Room Occupancy n DND Status n MUR Status
ased on specific customer requirements.
Integration with Building Management Systems (BMS)nt software has all the information regarding room status including temperature available in its database.
temperature to be controlled from the BMS console.
Integration with Property Management Systems(PMS)
ADMINNETWORK
PMS
SYSTEM
CENTRALAC
SYSTEM
GRMS - Centralized System
Guestroom 1 Guestroom 2
Hotel Ethernet Network
Central PC
Service Console
Guestroom 3..................................Guestroom N
13
Central Monitoring and Control Software for GRMS & Access Control
Installed on a central PC:n Room status monitoring such as Do-not-Disturb, Make-up-Room, Laundry, Make-up-Room-to-let, Ready-to-let, Maid Call, Guest occupancy, unscheduled occupancy, Out of order, Panic alert, Smoke Alert and many more according to the customer specifications.n Control various parameters such as temperature in the room.n Alarm logsn Encoding of cards for access controln Check in/Check Outn Access control rightsn Access control logsn Common area management for accessn Centralized console for Front Desk & House Keepingn Special Security Console
�e technical architecture is based on:n Client/Servern Modular System Componentsn Hardware key protection
Central Monitoring and Control Software for RMS and Access Control
1
(GRMS) is to provide convenience to the guest, enhance the
operator’s management control and provide energy savings.
GRMS is based on an integrated DIN
all the control devices such as relays, dimmers and FCU
control modules. Auxiliary control devices such as wall
mounted control panels, thermostats, DND/MUR
indicator and Key card holders provides the control user
interfaces to the system.
Highlights
n One solution to offer excellent guest experience
n Beautiful aesthetics that blend into any environment
n Highly economical solution with rich functionality
n Reliable technology, designed for guest comfort
n Flexibility to choose from a wide range of choices
n All that luxury, essentially without all that cost
n Simplicity
Integration with Property Management Systems (PMS)an be interfaced with the PMS. It will receive at the minimum the following information from PMS:
n Room rented StatusIt will transmit at minimum the following information to PMS: n Room Occupancy n DND Status n MUR Status
ased on specific customer requirements.
Integration with Building Management Systems (BMS)nt software has all the information regarding room status including temperature available in its database.
temperature to be controlled from the BMS console.
Integration with Property Management Systems(PMS)
ADMINNETWORK
PMS
SYSTEM
CENTRALAC
SYSTEM
GRMS - Centralized System
Guestroom 1 Guestroom 2
Hotel Ethernet Network
Central PC
Service Console
Guestroom 3..................................Guestroom N
13
Central Monitoring and Control Software for GRMS & Access Control
Installed on a central PC:n Room status monitoring such as Do-not-Disturb, Make-up-Room, Laundry, Make-up-Room-to-let, Ready-to-let, Maid Call, Guest occupancy, unscheduled occupancy, Out of order, Panic alert, Smoke Alert and many more according to the customer specifications.n Control various parameters such as temperature in the room.n Alarm logsn Encoding of cards for access controln Check in/Check Outn Access control rightsn Access control logsn Common area management for accessn Centralized console for Front Desk & House Keepingn Special Security Console
�e technical architecture is based on:n Client/Servern Modular System Componentsn Hardware key protection
Central Monitoring and Control Software for RMS and Access Control
1
n Key Card Holder
n
LCD Screen
FAN+ FAN-
1
2 3
4 3
Access Control
Card ReaderContactless RFID Card Reader behind the corridor panel
Features:n Radio Frequency Identification (RFID)n Integrate to hotel loyalty programs, vendor payments etc.
Key Card Holdere room gen
can be inserted in the card holder upon entry into the room and a pre-programmed welcome scene is activated. When the key card is taken out, the entire load except the mini bar will be turned off after a delay of 30 seconds (this delay is adjustable according to the customer’s specification). Different cards are used to
for Do Not Disturb & Make up Room.
e guest can requestrespective indicator on the courtesy panel outside the room and it will remain on until attended or cancelled.
Digital ostatrally wall mounted inside the room in
a location which is easily visible to the guest. It is used as user interface to control the air conditioning in the room.
Its salient features are: n Switches for temperature setting n Set temperature or actual ambient temperature display n Fan speed control using +/- buttons n Low voltage operation n Temperature can be varied in 1º C steps n LED display with adjustable brightness
TEMP+ TEMP- Fan speed +/-buttons: and
Temperature +- buttons: and
Fan speed indicators
Card Encoder�e QL-ENC RF is a RFID encoder for the Qlite RFID MIFARE locks. It is a 13.56MHz USB contactless RFID reader / encoder. �e encoder is generally placed in the reception for the Guest card encoding and one with the security in-charge for card encoding for the internal hotel staff.
Handheld RFID Lock Programmer�e QL-LPRG is a handheld programmer for the Qlite RFID locks Series. �is device is needed to program each lock individually once
to allocate room number to each lock. �e device also reads the audittrail from the locks and connects to a PC to backup the records.
KeycardsQlite offers various RFID cards (e.g. for guests or staff ).
Courtesy Panel without Card Reader It h
are turned on when the guest requests for the same by using switches on the internal DND, MUR & Laundry service panel. On pressing
request status. Chimes are stored as wave files and our RCU has full control over the chime unit. Our Courtesy Panel will have all the necessary indications and switches as specified by the customer.
n Make-up Room (LED Indication) n Do Not Disturb (LED Indication) n Laundry (LED Indication) n Bell Push (Chime)
Courtesy Panel with Card ReaderProximity Card Reader. When the guest or staff shows the access card it will grant
management software to ensure real time security access.
nt features of the card reader panel:It can identify the following 2 types of cards.n Guestn Staff
Features: LEDs on the front panel light up to display the following states:n Access Allowed / Access Denied n DND, MUR & Laundry Statusn Integration with third party system
Courtesy Panel
ENIGMAS E R I E S
C e n t r a l i s e d G R M S
S t a n d a l o n e G R M S
Courtesy panel�e QL-CPH01S is glass finish touch type corridor panel for the stand alone Guest Room Management System. It operates on 230V AC power. �e service indication icons are backlit with LEDs for various services and bell touch button. �e icons and color scheme on the panel are fully customizable as per project requirement. �e QL-CPH01S is available in a screw less clip-on construction with various finishes. It has a flush mounting plate which fits into a standard single gang 3” X 3” back box.
Keycard Holder�e QL-CPKT01S is an energy saving keycard holder module. It is available in white and black plastic as standard finishes. It is an elegant user interface for energy saving. It operates on 230V AC. It switches a load of 5A and is generally used with a contactor for higher or number of loads. �e QL-CPKT01S is available in a screw less clip-on construction and fits into a standard single gang 3” X 3” back box.
Note: Intelligent RFID keycard holcer option is also available.
Service Selection Panel�e QL-CPB01S is glass finish touch type service selection panel for Qlite standalone Guest Room Management System. It operates of 230 V AC. It is an elegant user interface for service selections like ‘do not disturb’, ‘service’ and ‘laundry’. �e QL-CPB01S is available in a screw less clip-on construction with black and white as standard finishes. It has a flush mounting plate which fits into a standard single gang 3” X 3” back box with fixing centres at 60.3mm. �e service indication icons are backlit
ELEGANTS E R I E S
GLASS TOUCH CORRIDOR PANEL GLASS TOUCH LIGHT CONTROL SWITCH
n Key Card Holder
n
LCD Screen
FAN+ FAN-
1
2 3
4 3
Access Control
Card ReaderContactless RFID Card Reader behind the corridor panel
Features:n Radio Frequency Identification (RFID)n Integrate to hotel loyalty programs, vendor payments etc.
Key Card Holdere room gen
can be inserted in the card holder upon entry into the room and a pre-programmed welcome scene is activated. When the key card is taken out, the entire load except the mini bar will be turned off after a delay of 30 seconds (this delay is adjustable according to the customer’s specification). Different cards are used to
for Do Not Disturb & Make up Room.
e guest can requestrespective indicator on the courtesy panel outside the room and it will remain on until attended or cancelled.
Digital ostatrally wall mounted inside the room in
a location which is easily visible to the guest. It is used as user interface to control the air conditioning in the room.
Its salient features are: n Switches for temperature setting n Set temperature or actual ambient temperature display n Fan speed control using +/- buttons n Low voltage operation n Temperature can be varied in 1º C steps n LED display with adjustable brightness
TEMP+ TEMP- Fan speed +/-buttons: and
Temperature +- buttons: and
Fan speed indicators
Card Encoder�e QL-ENC RF is a RFID encoder for the Qlite RFID MIFARE locks. It is a 13.56MHz USB contactless RFID reader / encoder. �e encoder is generally placed in the reception for the Guest card encoding and one with the security in-charge for card encoding for the internal hotel staff.
Handheld RFID Lock Programmer�e QL-LPRG is a handheld programmer for the Qlite RFID locks Series. �is device is needed to program each lock individually once
to allocate room number to each lock. �e device also reads the audittrail from the locks and connects to a PC to backup the records.
KeycardsQlite offers various RFID cards (e.g. for guests or staff ).
1
Room Control Unit (RCU)
is located within the room and is generally not easily visible to the guest.
with the central monitoring software and provides the status of the room.
It is an intelligent microprocessor based controller having the following: n Micro-processor based System Interface Module n Switching Modulen Dimming Module n FCU Controller n TCP/IP Connectivity
In an event of power failure, it is possible to bypass the entire system and the designated
2 to 3 sec to reduce sudden loading when power returns after a power failure or shutdown. RCU can be expanded without having to replace the original relay boards. When the power resumes after power failure, the last status will be restored.
nclosed in a metal chassis enclosure, provided with sufficient ventilation. It has knock-out holes (dia. 25mm) for cable entry conduits. Entire connections to andfrom this unit are with suitable control cables.
Room Control Unit(RCU)
9
Multi Function Control Panels
5
Dimming Control Panelmounted at various convenient locations within the room.
Lighting Control Panelient locations within the room.
It can have up to 6 switches on one panel.
Curtain Control
Curtains can be controlled via multi function control panel or the bed side panel.
DND/MUR Service Panel is wall mounted inside the room, either as a seperate panel or part of bedside
the respective switches on the panel which will turn on the respective indicator on the courtesy panel outside the room.
DND - Do Not Disturbdes complete privacy for the guest. When pressed the DND
while pressing the door chime the DND display will flash.
MUR – Make-up RoomWhen pressed, the MUR indicator on the courtesy panel will be activated and the message will be sent through the network to housekeeping/reception/laundry
central management software through the RCU.
Wireless Bed Side Panel
State-of- the-art Wireless Bed Side Panel
ersion of the bthat allows guest to control Lighting, Dimming, Air-conditioning and also features the service buttons (DND, MUR & Laundry). It also has a master switch through which all the lights can be switched off except the night light and bathroom light (this can be changed according to customers’ specifications). Normal function will resume once any key is pressed. It also has a display that will show real time temperature and time.
Membrane Push Button Option
Door/Window Contact
Bedside Panel
Bedside panel is a wall mounted, table top or portable
finish is matt black glass but the panels are also available with special finishes like Champagne Gold, White or any other finish as per special order to suite both the functional and aesthetic requirements of the customer. Since Qlite believes that the Bedside Panel should reflect the identity of the Hotel, a complete customization is provided for the hotel owner to the extent that even the hotel logo is
Standard Bedside Panel
Bedside Panel with Builtin Digital �ermostat
displayed on the panel.
Bedside Panel
Door/Window Contact
dow to monitor whether the door or window is opened or closed. It is connected to the RCU using volt free contacts and it can be used to control the air conditioning more efficiently.
7
Door/Window Contact
Bedside Panel
Bedside panel is a wall mounted, table top or portable
finish is matt black glass but the panels are also available with special finishes like Champagne Gold, White or any other finish as per special order to suite both the functional and aesthetic requirements of the customer. Since Qlite believes that the Bedside Panel should reflect the identity of the Hotel, a complete customization is provided for the hotel owner to the extent that even the hotel logo is
Standard Bedside Panel
Bedside Panel with Builtin Digital �ermostat
displayed on the panel.
Bedside Panel
Door/Window Contact
dow to monitor whether the door or window is opened or closed. It is connected to the RCU using volt free contacts and it can be used to control the air conditioning more efficiently.
7
Multi Function Control Panels
5
Dimming Control Panelmounted at various convenient locations within the room.
Lighting Control Panelient locations within the room.
It can have up to 6 switches on one panel.
Curtain Control
Curtains can be controlled via multi function control panel or the bed side panel.
DND/MUR Service Panel is wall mounted inside the room, either as a seperate panel or part of bedside
the respective switches on the panel which will turn on the respective indicator on the courtesy panel outside the room.
DND - Do Not Disturbdes complete privacy for the guest. When pressed the DND
while pressing the door chime the DND display will flash.
MUR – Make-up RoomWhen pressed, the MUR indicator on the courtesy panel will be activated and the message will be sent through the network to housekeeping/reception/laundry
central management software through the RCU.
Wireless Bed Side Panel
State-of- the-art Wireless Bed Side Panel
ersion of the bthat allows guest to control Lighting, Dimming, Air-conditioning and also features the service buttons (DND, MUR & Laundry). It also has a master switch through which all the lights can be switched off except the night light and bathroom light (this can be changed according to customers’ specifications). Normal function will resume once any key is pressed. It also has a display that will show real time temperature and time.
Membrane Push Button Option
1
Room Control Unit (RCU)
is located within the room and is generally not easily visible to the guest.
with the central monitoring software and provides the status of the room.
It is an intelligent microprocessor based controller having the following: n Micro-processor based System Interface Module n Switching Modulen Dimming Module n FCU Controller n TCP/IP Connectivity
In an event of power failure, it is possible to bypass the entire system and the designated
2 to 3 sec to reduce sudden loading when power returns after a power failure or shutdown. RCU can be expanded without having to replace the original relay boards. When the power resumes after power failure, the last status will be restored.
nclosed in a metal chassis enclosure, provided with sufficient ventilation. It has knock-out holes (dia. 25mm) for cable entry conduits. Entire connections to andfrom this unit are with suitable control cables.
Room Control Unit(RCU)
9
n Key Card Holder
n
LCD Screen
FAN+ FAN-
1
2 3
4 3
Access Control
Card ReaderContactless RFID Card Reader behind the corridor panel
Features:n Radio Frequency Identification (RFID)n Integrate to hotel loyalty programs, vendor payments etc.
Key Card Holdere room gen
can be inserted in the card holder upon entry into the room and a pre-programmed welcome scene is activated. When the key card is taken out, the entire load except the mini bar will be turned off after a delay of 30 seconds (this delay is adjustable according to the customer’s specification). Different cards are used to
for Do Not Disturb & Make up Room.
e guest can requestrespective indicator on the courtesy panel outside the room and it will remain on until attended or cancelled.
Digital ostatrally wall mounted inside the room in
a location which is easily visible to the guest. It is used as user interface to control the air conditioning in the room.
Its salient features are: n Switches for temperature setting n Set temperature or actual ambient temperature display n Fan speed control using +/- buttons n Low voltage operation n Temperature can be varied in 1º C steps n LED display with adjustable brightness
TEMP+ TEMP- Fan speed +/-buttons: and
Temperature +- buttons: and
Fan speed indicators
Card Encoder�e QL-ENC RF is a RFID encoder for the Qlite RFID MIFARE locks. It is a 13.56MHz USB contactless RFID reader / encoder. �e encoder is generally placed in the reception for the Guest card encoding and one with the security in-charge for card encoding for the internal hotel staff.
Handheld RFID Lock Programmer�e QL-LPRG is a handheld programmer for the Qlite RFID locks Series. �is device is needed to program each lock individually once
to allocate room number to each lock. �e device also reads the audittrail from the locks and connects to a PC to backup the records.
KeycardsQlite offers various RFID cards (e.g. for guests or staff ).
Central Monitoring and Control Software for GRMS & Access Control
Installed on a central PC:n Room status monitoring such as Do-not-Disturb, Make-up-Room, Laundry, Make-up-Room-to-let, Ready-to-let, Maid Call, Guest occupancy, unscheduled occupancy, Out of order, Panic alert, Smoke Alert and many more according to the customer specifications.n Control various parameters such as temperature in the room.n Alarm logsn Encoding of cards for access controln Check in/Check Outn Access control rightsn Access control logsn Common area management for accessn Centralized console for Front Desk & House Keepingn Special Security Console
n Client/Servern Modular System Componentsn Hardware key protection
Central Monitoring and Control Software for RMS and Access Control
1111
(GRMS) is to provide convenience to the guest, enhance the
operator’s management control and provide energy savings.
GRMS is based on an integrated DIN
all the control devices such as relays, dimmers and FCU
control modules. Auxiliary control devices such as wall
mounted control panels, thermostats, DND/MUR
indicator and Key card holders provides the control user
interfaces to the system.
Highlights
n One solution to offer excellent guest experience
n Beautiful aesthetics that blend into any environment
n Highly economical solution with rich functionality
n Reliable technology, designed for guest comfort
n Flexibility to choose from a wide range of choices
n All that luxury, essentially without all that cost
n Simplicity
Integration with Property Management Systems (PMS)an be interfaced with the PMS. It will receive at the minimum the following information from PMS:
n Room rented StatusIt will transmit at minimum the following information to PMS: n Room Occupancy n DND Status n MUR Status
ased on specific customer requirements.
Integration with Building Management Systems (BMS)nt software has all the information regarding room status including temperature available in its database.
to allow temperature to be controlled from the BMS console.
ADMINNETWORK
PMS
SYSTEM
CENTRALAC
SYSTEM
GRMS - Centralized System
Guestroom 1 Guestroom 2
Hotel Ethernet Network
Central PC
Service Console
Guestroom 3..................................Guestroom N
Integration with Property Management Systems(PMS)
Disclaimer: Our R & D team works towards continuous improvement in product designs and features. Please check with us for the latest information pertaining to this catalog.
Courtesy Panel without Card Reader It h
are turned on when the guest requests for the same by using switches on the internal DND, MUR & Laundry service panel. On pressing
request status. Chimes are stored as wave files and our RCU has full control over the chime unit. Our Courtesy Panel will have all the necessary indications and switches as specified by the customer.
n Make-up Room (LED Indication) n Do Not Disturb (LED Indication) n Laundry (LED Indication) n Bell Push (Chime)
Courtesy Panel with Card ReaderProximity Card Reader. When the guest or staff shows the access card it will grant
management software to ensure real time security access.
nt features of the card reader panel:It can identify the following 2 types of cards.n Guestn Staff
Features: LEDs on the front panel light up to display the following states:n Access Allowed / Access Denied n DND, MUR & Laundry Statusn Integration with third party system
Courtesy Panel
ENIGMAS E R I E S
C e n t r a l i s e d G R M S
S t a n d a l o n e G R M S
Courtesy panel�e QL-CPH01S is glass finish touch type corridor panel for the stand alone Guest Room Management System. It operates on 230V AC power. �e service indication icons are backlit with LEDs for various services and bell touch button. �e icons and color scheme on the panel are fully customizable as per project requirement. �e QL-CPH01S is available in a screw less clip-on construction with various finishes. It has a flush mounting plate which fits into a standard single gang 3” X 3” back box.
Keycard Holder�e QL-CPKT01S is an energy saving keycard holder module. It is available in white and black plastic as standard finishes. It is an elegant user interface for energy saving. It operates on 230V AC. It switches a load of 5A and is generally used with a contactor for higher or number of loads. �e QL-CPKT01S is available in a screw less clip-on construction and fits into a standard single gang 3” X 3” back box.
Note: Intelligent RFID keycard holcer option is also available.
Service Selection Panel�e QL-CPB01S is glass finish touch type service selection panel for Qlite standalone Guest Room Management System. It operates of 230 V AC. It is an elegant user interface for service selections like ‘do not disturb’, ‘service’ and ‘laundry’. �e QL-CPB01S is available in a screw less clip-on construction with black and white as standard finishes. It has a flush mounting plate which fits into a standard single gang 3” X 3” back box with fixing centres at 60.3mm. �e service indication icons are backlit
ELEGANTS E R I E S
GLASS TOUCH CORRIDOR PANEL GLASS TOUCH LIGHT CONTROL SWITCH
EUROPE HEADQUARTERS: Qlite LimitedUnit 4, Severnlink, Newhouse Farm Industrial EstateChepstow, NP16 6UN,United KingdomTel: +44 (0) 1600 772297Fax: +44 (0) 1600 551197Email: [email protected]
ASIA PACIFIC HEADQUARTERS: Qlite Electronics Controls P. LimitedOffice 539-540, Tower B3, Spaze I Tech Park, Spaze Tower, Sohna Road, Gurgaon, Haryana, IndiaTel : +91 124 4264701 - 08Email: [email protected]
MIDDLE EAST & AFRICA HEADQUARTERS:Qlite (FZC)P.O. Box 120768, Sharjah Airport International Free (SAIF) Zone, Sharjah, UAETel/Fax: +971 6 5579 618Email: [email protected]
©20
15 e
ditio
n