TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106 TEST REPORT NUMBER: EC1104836 EQUIPMENT TESTED: Power Supply MODEL NO(S): MPMIL1540-2222 SERIAL NO(S): N/A TEST DATE(S): 31 May 2011 02-14 and 17-22 June 2011 PREPARED FOR: Lind Electronics Design Company 6414 Cambridge Street St. Louis Park MN 55426-4420 CUSTOMER REQUESTER: Russ Babinski 952 927 6303 TEST LOCATION 1: TÜV SÜD America Inc New Brighton Laboratory 1775 Old Highway 8 NW, Suite 104 New Brighton Minnesota 55112-1891 USA 651 631 2487 TEST LOCATION 2: Environ Laboratories 9725 Girard Avenue S Minneapolis Minnesota 55431 USA 651 631 2487 TEST LOCATION 3: TÜV SÜD America Inc Holland Laboratory 345 E. 48 th Street Holland Michigan 49423 USA 616 546 3902 PREPARED BY: TÜV SÜD America Inc New Brighton Laboratory 1775 Old Highway 8 NW, Suite 104 New Brighton Minnesota 55112-1891 USA 651 631 2487 TÜV SÜD America Inc reports apply only to the specific samples tested under stated test conditions. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. TÜV SÜD America Inc shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD America Inc issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. This report shall not be used by the client to claim product endorsement by NVLAP, NIST, or any agency of the US government. TÜV SÜD America Inc and its professional staff hold government and professional organization certifications and are members of AAMI, ACIL, AEA, ANSI, IEEE, NARTE, and VCCI.. NVLAP Lab Code #100271-0 Test Report EC1104836 Page 1 of 66

Upload: others

Post on 17-Feb-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

TEST REPORT NUMBER: EC1104836 EQUIPMENT TESTED: Power Supply

MODEL NO(S): MPMIL1540-2222

SERIAL NO(S): N/A

TEST DATE(S): 31 May 2011

02-14 and 17-22 June 2011

PREPARED FOR: Lind Electronics Design Company 6414 Cambridge Street St. Louis Park MN 55426-4420

CUSTOMER REQUESTER: Russ Babinski 952 927 6303

TEST LOCATION 1: TÜV SÜD America Inc New Brighton Laboratory 1775 Old Highway 8 NW, Suite 104 New Brighton Minnesota 55112-1891 USA 651 631 2487

TEST LOCATION 2: Environ Laboratories 9725 Girard Avenue S Minneapolis Minnesota 55431 USA 651 631 2487

TEST LOCATION 3: TÜV SÜD America Inc Holland Laboratory 345 E. 48th Street Holland Michigan 49423 USA 616 546 3902

PREPARED BY: TÜV SÜD America Inc New Brighton Laboratory 1775 Old Highway 8 NW, Suite 104 New Brighton Minnesota 55112-1891 USA 651 631 2487

TÜV SÜD America Inc reports apply only to the specific samples tested under stated test conditions. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. TÜV SÜD America Inc shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD America Inc issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval. This report shall not be used by the client to claim product endorsement by NVLAP, NIST, or any agency of the US government.

TÜV SÜD America Inc and its professional staff hold government and professional organization certifications and are members of AAMI, ACIL, AEA, ANSI, IEEE, NARTE, and VCCI.. NVLAP Lab Code #100271-0

Test Report EC1104836 Page 1 of 66

Page 2: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

REVISION RECORD

REVISION TOTAL

NUMBER OF PAGES

DATE DESCRIPTION

66 21 July 2011 Initial Release

Test Report EC1104836 Page 2 of 66

Page 3: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

DIRECTORY

Revision Record .................................................................................................................................................... 2

Directory ................................................................................................................................................................ 3

1.0 Test Summary ................................................................................................................................................. 4

2.0 Test Results .................................................................................................................................................... 5

2.1 Mil-Std-810G, Method 500.5, Procedure II, Low Pressure (Altitude) Testing ......................................... 5

2.2 Mil-Std-810G, Method 501.5, Procedure II, High Temperature (Operating) Testing ............................. 6

2.3 Mil-Std-810G, Method 502.5, Procedure II, Low Temperature (Operating) Testing .............................. 6

2.4 Mil-Std-810G, Method 503.5, Procedure I, Temperature Shock Testing ................................................ 6

2.5 Mil-Std-810G, Method 507.5, Procedure II, Humidity Testing ................................................................. 6

2.6 Mil-Std-810G, Method 510.5, Procedure I, Blowing Dust Testing ........................................................... 7

2.7 Mil-Std-810G, Method 514.6, Procedure I, Vibration Testing ................................................................. 7

2.8 Mil-Std-810G, Method 516.6, Procedure I, Shock Testing ..................................................................... 8

3.0 Modifications Required To Pass ...................................................................................................................... 8

4.0 Test Specification Deviations: Additions To Or Exclusions From ................................................................... 8

5.0 Statement Of Measurement Uncertainty ......................................................................................................... 8

Appendix A: Test Setup Photos ............................................................................................................................ 9 - 18

Appendix B: Test Equipment List .......................................................................................................................... 19 - 20

Appendix C: Test Procedure ................................................................................................................................. 21

Test Data Sheets Appendices:

Appendix D: Mil-Std-810G, Method 500.5, Procedure II, Low Pressure (Altitude) ........................................ 22 - 24

Appendix E: Mil-Std-810G, Method 501.5, Procedure II, High Temperature (Operating) ............................. 25 - 27

Appendix F: Mil-Std-810G, Method 502.5, Procedure II, Low Temperature (Operating) .............................. 28 - 30

Appendix G: Mil-Std-810G, Method 503.5, Procedure I, Temperature Shock .............................................. 31 - 33

Appendix H: Mil-Std-810G, Method 507.5, Procedure II, Humidity ............................................................... 34 - 37

Appendix I: Mil-Std-810G, Method 510.5, Procedure I, Blowing Dust (Environ report # 44303-1) ................ 38 - 47

Appendix J: Mil-Std-810G, Method 514.6, Procedure I, Vibration ................................................................ 48 - 52

Appendix K: Mil-Std-810G, Method 516.6, Procedure I, Shock (TÜV Holland Report # H-7863) ................. 53 - 66

Test Report EC1104836 Page 3 of 66

Page 4: Environmental 810G-1 - Amazon Web Services

Tested By: Reviewed By:

Stephen J Siech James E Mills

EMC/Environmental Technician Environmental Lead Engineer

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

TEST REPORT NO.: EC1104836

COMPANY: Lind Electronics Design Company

EQUIPMENT UNDER TEST: REQUESTER: Russ Babinski

Power Supply PHONE #: 952 927 6303

Model No(s): MPMIL1540-2222 DATE(S) TESTED: 31 May 2011 02-14 and 17-22 June 2011

Serial No(s): N/A

STANDARDS / DOCUMENTS: Mil-Std-810G – Department of Defense Test Method Standard for Environmental Engineering Considerations and

Laboratory Tests, 31 October 2008.

1.0 TEST SUMMARY Environmental testing was performed on the Power Supply at the New Brighton Laboratory of TÜV SÜD America Inc located in New Brighton, Minnesota and Holland, Michigan, and Environ Laboratories LLC located in Minneapolis, Minnesota. The test requirements and procedures were specified in Mil-Std-810G, per TÜV SÜD Quotation no. CG480422223700, dated 18 May 2011.

The information presented in this report is, to the best of our knowledge, true and correct in all respects.

Test Report EC1104836 Page 4 of 66

Page 5: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

2.0 TEST RESULTS All testing was performed to Mil-Std-810G, per TÜV SÜD Quotation no. CG480422223700, dated 18 May 2011. The Equipment Under Test was a Power Supply. The Power Supply was identified by its model number and tested according to the table below. Testing was performed in accordance with the Documents referenced in Section 1, utilizing TÜV America's Environmental Lab test chambers, fixtures, and test equipment as indicated in Appendix B, except as noted below. The EUT was monitored during testing (where appropriate) by TÜV personnel and customer-provided hardware.

Serial Number(s)

Tested

Appendix Reference

Description Requirement Result Ph

oto

s

Dat

a

Low Pressure (Altitude) Mil-Std-810G, Method 500.5, Procedure II (1) Pass n/a A D

High Temperature (Operating)

Mil-Std-810G, Method 501.5, Procedure II (1) Pass n/a A E

Low Temperature (Operating) Mil-Std-810G, Method 502.5, Procedure II (1) Pass n/a A F

Temperature Shock Mil-Std-810G, Method 503.5, Procedure I (1) Pass n/a A G

Humidity Mil-Std-810G, Method 507.5, Procedure II (1) Pass n/a A H

Blowing Dust Mil-Std-810G, Method 510.5, Procedure I Pass NOTE 1 n/a I I

Vibration Mil-Std-810G, Method 514.5, Procedure I (1) Pass n/a A J

Shock Mil-Std-810G, Method 516.5, Procedure I Pass

NOTE 2 n/a K K

(1) Test Methods not covered under NVLAP Lab Code #100271-0 Scope of Accreditation. The referenced accreditation does in clude Mil-Std-810F. The addition of Mil-Std-810G is pending.

Note 1 Blowing Dust testing was performed at Environ Laboratories, located in Minneapolis, MN. Refer to the Environ report number 44303-1 in Appendix I for testing details.

Note 2 Shock testing was performed at TÜV SÜD - Holland, located in Holland, MI. Refer to TÜV report number

H-7863 in Appendix K for testing details. 2.1 LOW PRESSURE (ALTITUDE) TESTING Low Pressure (Altitude) testing was performed on one (1) Power Supply as indicated in Section 2.0, according to the requirements of Mil-Std-810G, Method 500.5, Procedure II per TÜV SÜD Quotation no. CG480422223700, dated 18 May 2011. With power applied to the Power Supply, the test sample was brought from laboratory ambient pressure to a simulated altitude of +15,000 ft. While operating, the Power Supply remained at this condition for one (1) hour. Refer to the Daily Test Status Log located in Appendix D, for specific testing details. The Power Supply did not exhibit any malfunction or evidence of physical damage after being subjected to these conditions.

Test Report EC1104836 Page 5 of 66

Page 6: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

2.2 HIGH TEMPERATURE (OPERATING) TESTING High Temperature testing was performed on one (1) Power Supply as indicated in Section 2.0, according to the requirements of Mil-Std-810G, Method 501.5, Procedure II per TÜV SÜD Quotation no. CG480422223700, dated 18 May 2011. With power applied to the Power Supply and operating, the Power Supply was subjected to two (2) hours of high temperature conditioning at +60° Celsius. Refer to the Daily Test Status Log located in Appendix E, for specific testing details. The Power Supply did not exhibit any malfunction or evidence of physical damage after being subjected to these conditions. 2.3 LOW TEMPERATURE (OPERATING) TESTING Low Temperature testing was performed on one (1) Power Supply as indicated in Section 2.0, according to the requirements of Mil-Std-810G, Method 502.5, Procedure II per TÜV SÜD Quotation no. CG480422223700, dated 18 May 2011. With power applied to the Power Supply and operating, the Power Supply was subjected to two (2) hours of cold temperature conditioning at -40° Celsius. Refer to the Daily Test Status Log located in Appendix F, for specific testing details. The Power Supply did not exhibit any malfunction or evidence of physical damage after being subjected to these conditions. 2.4 TEMPERATURE SHOCK TESTING Temperature Shock testing was performed on one (1) Power Supply as indicated in Section 2.0, according to the requirements of Mil-Std-810G, Method 503.5, Procedure I-C per TÜV SÜD Quotation no. CG480422223700, dated 18 May 2011. With no power applied to the Power Supply, the Power Supply was subjected to three (3) cycles with a high temperature +85° Celsius and low temperature of -40° Celsius. The duration at each temperature is thirty (30) minutes. Refer to the Daily Test Status Log located in Appendix G, for specific testing details. The Power Supply did not exhibit any malfunction or evidence of physical damage after being subjected to these conditions. 2.5 HUMIDITY TESTING Humidity testing was performed on one (1) Power Supply as indicated in Section 2.0, according to the requirements of Mil-Std-810G, Method 507.5, Procedure II per TÜV SÜD Quotation no. CG480422223700, dated 18 May 2011. With no power applied to the Power Supply, the Power Supply was subjected to an aggravated humidity cycle with a duration of two hundred forty (240) hours. The Power Supply was operationally checked after five (5) days of condition and at the end of the aggravated cycle test. Refer to the Daily Test Status Log located in Appendix H, for specific testing details. The Power Supply did not exhibit any malfunction or evidence of physical damage after being subjected to these conditions.

Test Report EC1104836 Page 6 of 66

Page 7: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

2.6 BLOWING DUST TESTING Dust testing was performed on one (1) Power Supply as indicated in Section 2.0, according to the requirements of Mil-Std-810G, Method 510.5, Procedure I per TÜV SÜD Quotation no. CG480422223700, dated 18 May 2011. Refer to the Environ Test Report # 44303-2 located in Appendix I, for specific testing details. 2.7 VIBRATION TESTING Vibration testing was performed on one (1) Power Supply as indicated in Section 2.0, according to the requirements of Mil-Std-810G, Method 514.6, Procedure I, Category 24, Figure 514.6E-1 per TÜV SÜD Quotation no. CG480422223700, dated 18 May 2011. With power applied to the Power Supply and operating, the Power Supply was mounted in its normal orientation and secured to the vibration system via the shaker armature and slip plate assembly. The Power Supply were subjected to the environmental conditions and operationally checked, where appropriate. The duration of this testing is one (1) hour.

Refer to Daily Test Status Log, located in Appendix J, for specific testing details. The Power Supply did not exhibit any malfunction or evidence of physical damage after being subjected to these conditions.

Test Report EC1104836 Page 7 of 66

Page 8: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

2.8 SHOCK TESTING Shock testing was performed on one (1) Power Supply as indicated in Section 2.0, according to the requirements of Mil-Std-810G, Method 516.6, Procedure I per TÜV SÜD Quotation no. CG480422223700, dated 18 May 2011. The Power Supply was mounted in its normal orientation and secured to the vibration system via the shaker armature and slip plate assembly. The Power Supply was subjected to the environmental conditions and operationally checked, where appropriate.

Acceleration: 40g Duration: 11 msec Pulse Shape: Terminal Sawtooth Axis: Vertical, Horizontal (fore/aft), Lateral Polarity: 3 Positive / 3 Negative

Refer to the TUV SUD - Holland Test Report # H-7863 located in Appendix K, for specific testing details. 3.0 MODIFICATIONS REQUIRED TO PASS: There were no modifications made to the EUT at the time of test. 4.0 TEST SPECIFICATION DEVIATIONS: ADDITIONS TO OR EXCLUSIONS FROM: There were no deviations made to the test specifications or plan at the time of testing. 5.0 STATEMENT OF MEASUREMENT UNCERTAINTY The data and results referenced in this document are accurate. The reader is cautioned that there is some measurement variability due to the tolerances of the test equipment that can contribute to a nominal product measurement uncertainty. Furthermore, component differences and manufacturing process variability of production units similar to that tested may result in additional product uncertainty. If necessary, refer to the test lab for the actual measurement uncertainty for specific tests.

Test Report EC1104836 Page 8 of 66

Page 9: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

APPENDIX A

TEST SETUP PHOTOS

Test Report EC1104836 Appendix A Page 9 of 66

Page 10: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Setup Photos: Low Pressure (Altitude)

Test Report EC1104836 Appendix A Page 10 of 66

Page 11: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Set-up Photos High Temperature (Operating) Low Temperature (Operating)

Test Report EC1104836 Appendix A Page 11 of 66

Page 12: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Setup Photos: Temperature Shock Testing

Test Report EC1104836 Appendix A Page 12 of 66

Page 13: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Setup Photos: Humidity Testing

Test Report EC1104836 Appendix A Page 13 of 66

Page 14: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Setup Photos: Blowing Dust Testing

Refer to Environ Test Report Number 44303-1 located in Appendix I

Test Report EC1104836 Appendix A Page 14 of 66

Page 15: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Setup Photos: Vibration Testing Vertical

Test Report EC1104836 Appendix A Page 15 of 66

Page 16: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Setup Photos: Vibration Testing Transverse

Test Report EC1104836 Appendix A Page 16 of 66

Page 17: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Setup Photos: Vibration Testing Longitudinal

Test Report EC1104836 Appendix A Page 17 of 66

Page 18: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Setup Photos: Shock Testing

Refer to Holland Test Report Number H-7863 located in Appendix K

Test Report EC1104836 Appendix A Page 18 of 66

Page 19: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

APPENDIX B

TEST EQUIPMENT LIST

Test Report EC1104836 Appendix B Page 19 of 66

Page 20: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

TEST EQUIPMENT Use of the calibrated equipment listed in this report ensures traceability to national and international standards. Test # Test Description / Performed by 1 Low Pressure (Altitude) / SJS 2 High Temperature (Operating) / SJS 3 Low Temperature (Operating) / SJS 4 Temperature Shock / SJS 5 Humidity / SJS & JEM 6 Blowing Dust / refer to Environ Test Report Number 44303-1 located in Appendix I 7 Vibration / SJS 8 Shock / refer to Holland Test Report Number H-7863 located in Appendix K Cal Code/ Test # Mfr Model Serial Description Due Date Asset ID 1 TNY 27STR-C-200K 26133-01 Altitude Chamber G 29-Jul-11 2424 2 ENV SH27 09963481-S 27 CuFt Temp/Humidity Chamber G 21-Jul-11 2235 3 ENV SH27 09963481-S 27 CuFt Temp/Humidity Chamber G 21-Jul-11 2235 4 TH ATS-32-V-705-705 11598 Thermal Shock Chamber G 29-Jul-11 2228 5 ENV SH27 09963481-S 27 CuFt Temp/Humidity Chamber G 21-Jul-11 2235 7 UD T1000 413 Shaker Y N/A 2200 7 UD MA145 732 Amplifier Y N/A 2200 7 VR VR9500 07A81F Revolution VibrationVIEW Controller G 2-June-12 10728 7 DII 3030B4 13153 Voltage Mode Accelerometer G 14-Apr-12 2250 7 DII 3030B4 13154 Voltage Mode Accelerometer G 14- Apr -12 2251 CALIBRATION CODES Cal Code G = Calibration performed by an accredited outside source. Cal Code Y = Calibration not required when used with other calibrated equipment. MANUFACTURER CODES DII Dytran Instruments ENV Envirotronics TH Thermotron TNY Tenney UD Unholtz-Dickie VR Vibration Research

Test Report EC1104836 Appendix B Page 20 of 66

Page 21: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

APPENDIX C

TEST REQUIREMENTS

The TÜV SÜD Quotation Number CG480422223700, dated 18 May 2011, is on file with TÜV SÜD America.

Test Report EC1104836 Appendix C Page 21 of 66

Page 22: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

APPENDIX D

TEST DATA SHEETS

Mil-Std-810G, Method 500.5, Procedure II Low Pressure (Altitude) Tests

Test Report EC1104836 Appendix D Page 22 of 66

Page 23: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix D Page 23 of 66

Page 24: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix D Page 24 of 66

Page 25: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

APPENDIX E

TEST DATA SHEETS

Mil-Std-810G, Method 501.5, Procedure II High Temperature (Operating) Tests

Test Report EC1104836 Appendix E Page 25 of 66

Page 26: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix E Page 26 of 66

Page 27: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix E Page 27 of 66

Page 28: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

APPENDIX F

TEST DATA SHEETS

Mil-Std-810G, Method 502.5, Procedure II Low Temperature (Operating) Tests

Test Report EC1104836 Appendix F Page 28 of 66

Page 29: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix F Page 29 of 66

Page 30: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix F Page 30 of 66

Page 31: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

APPENDIX G

TEST DATA SHEETS

Mil-Std-810G, Method 503.5, Procedure I-C Temperature Shock Tests

Test Report EC1104836 Appendix G Page 31 of 66

Page 32: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix G Page 32 of 66

Page 33: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix G Page 33 of 66

Page 34: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

APPENDIX H

TEST DATA SHEETS

Mil-Std-810G, Method 507.5, Procedure II Humidity Tests

Test Report EC1104836 Appendix H Page 34 of 66

Page 35: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix H Page 35 of 66

Page 36: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix H Page 36 of 66

Page 37: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix H Page 37 of 66

Page 38: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

APPENDIX I

TEST DATA SHEETS

Mil-Std-810G, Method 510.5, Procedure I Blowing Dust Tests

Environ Test Report Number 44303-1

Test Report EC1104836 Appendix I Page 38 of 66

Page 39: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix I Page 39 of 66

Page 40: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix I Page 40 of 66

Page 41: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix I Page 41 of 66

Page 42: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix I Page 42 of 66

Page 43: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix I Page 43 of 66

Page 44: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix I Page 44 of 66

Page 45: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix I Page 45 of 66

Page 46: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix I Page 46 of 66

Page 47: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix I Page 47 of 66

Page 48: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

APPENDIX J

TEST DATA SHEETS

Mil-Std-810G, Method 514.6, Procedure I Vibration Tests

Test Report EC1104836 Appendix J Page 48 of 66

Page 49: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix J Page 49 of 66

Page 50: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix J Page 50 of 66

Page 51: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix J Page 51 of 66

Page 52: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix J Page 52 of 66

Page 53: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

APPENDIX K

TEST DATA SHEETS

Mil-Std-810G, Method 516.6, Procedure I Shock Tests

TUV SUD - Holland Test Report Number H-7863

Test Report EC1104836 Appendix K Page 53 of 66

Page 54: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix K Page 54 of 66

Page 55: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix K Page 55 of 66

Page 56: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix K Page 56 of 66

Page 57: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix K Page 57 of 66

Page 58: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix K Page 58 of 66

Page 59: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix K Page 59 of 66

Page 60: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix K Page 60 of 66

Page 61: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix K Page 61 of 66

Page 62: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix K Page 62 of 66

Page 63: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix K Page 63 of 66

Page 64: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix K Page 64 of 66

Page 65: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix K Page 65 of 66

Page 66: Environmental 810G-1 - Amazon Web Services

TÜV SÜD America Inc 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev. 091106

Test Report EC1104836 Appendix K Page 66 of 66