2.1 Product Specifi cations
MaximumOperatingPressure:50psi InputFreq:60HzMinimumFlowRate:76lpm(20gpm) OutputVoltage:25VDC(max)RequiredSaltLevel:3.0gpl(3,000ppm) Dimensions:
PowerPack(LxWxH):25.4cmx11.4cmx33cm(10in.x4.5in.x13in.)ElectrolyticCell(LxWxH):16.5cmx14cmx30.5cm(6.5in.x5.5in.x12in.)
Maximumwatervolumetreated:132,000L(35,000gal.)ChlorineOutput:0.42kg(0.93lbs.)perday
InputVoltages:240VAC Weight:PowerPack:3.2kg.(7lbs)ElectrolyticCell:0.9kg(2lbs.)
InputCurrent@240VAC:~1A
HEATER
CELL
FILTER
POWER PACKTO COMMON
POWER SOURCE
CHECK VALVE
RETURN WATER FEATURE /IN FLOOR CLEANER
INTAKE
PUMP
ENGLISH
The cell must be installed as the last piece of equipment in the circulation plumbing system just before the pool.
Page 7 ENGLISH Jandy® Pro Series TruClear™ Chlorine Generating System | Installation & Operation Manual
2.2 Product Contents
A* B
C D*H0
4706
00_R
EVB
ENGLISH | FRANÇAIS | ESPAÑOL
WARNINGFOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist. The maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal
injury, or death. Improper installation and/or operation will void the warranty.Improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, or death.
ATTENTION INSTALLER - This manual contains important information about the ot nevig eb dluohs noitamrofni sihT .tcudorp siht fo esu efas dna noitarepo ,noit al lats ni
the owner/operator of this equipment.
INSTALLATION AND OPERATION MANUAL
Jandy Pro SeriesTruClear™
Chlorine Generating System
Figure 2. Carton Contents
Items Included
ITEM DESCRIPTION QTYA PowerPack 1B Cell(Itemshownisthestandardcell.A
versionwithunionsisanavailableoption)1
C InstallationandOperationManual 1
* Items Sold Separately as Replacement Parts
ITEM DESCRIPTION Part#D WinterizingCap R0621900
TRUCLEARCELL
notshown CellAssemblyOnly(noHousing) R0693900notshown HousingOnlywithUnions(noCell) R0694000notshown O-Ring R0694100
A PowerPack R0663700POWERPACKnotshown CoverAssemblywithUserInterface R0663800
notshown PCBAssembly R0663900