energy efficiency and renewables success stories in …s... · energy efficiency and renewables...

31
Presentation title in footer | 00 Month 0000 1 Energy Efficiency and Renewables Success Stories in Energy Reduction EMD Millipore Paul Lukitsch CEM World Wide Energy Manager

Upload: ngocong

Post on 29-Apr-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Presentation title in footer | 00 Month 00001

Energy Efficiency and RenewablesSuccess Stories in Energy ReductionEMD Millipore

Paul Lukitsch CEMWorld Wide Energy Manager

Page 2: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Agenda

Sustainability ProgramEnergy Management ProgramHow to get startedSuccess stories in Energy Reduction

Page 3: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Our Sustainability Vision

Our operations will become environmentally sustainable in the long-term by dramatically reducing the consumption of non-renewable resources, reducing waste and adopting behavioral changes that support sustainability company wide.

Page 4: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

EMD Millipore at a Glance

Millipore’s products and services help our customers in biotechnology, life science, and pharmaceutical industries discover, develop, scale up and manufacture novel therapeutic compounds.

Approximately. $1.8B

~6,000 employees worldwide

Offices in more than 31 countries.

R&D, Manufacturing, Distribution, Office

US Headquarters in Billerica, MA

Page 5: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Strategic Priorities and Goals

Health & SafetyWorkplace

Employee EngagementCorporate Giving

Empl

oyee

s &

C

omm

unity Increase stakeholder

engagement Drive risk reductionTarget donations and motivateemployee volunteering

Design for SustainabilityProduct Recycling

Supply ChainPackaging

Prod

ucts

&

Cus

tom

ers

Apply Design for Sustainabilityto 100% of our productsDevelop product take back programs for consumables

Climate & EnergyWasteWater

Envi

ronm

ent

MM: Reduce GHGs 20% below2006 baseline, by end of 2011Merck: Reduce GHGs 20% below 2006 baseline, by 2020

Page 6: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Driving Innovation, Developing Solutions

• Sustainability scorecard for products• Conduct life cycle assessments• Provide training to designers• Develop top line growth• Use of biodegradable plastics• Partner with customers and suppliers

Page 7: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Invest in People: Magnet for Talent

• Magnet for Talent • 160 employees enrolled in flexible workplace program• Interactive website with videos on home improvements• Launched sustainable incentive programs

-Energy audits-Solar installations-Hybrid vehicles

Page 8: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Key Highlights: Increasing Efficiency, Improving Performance

• 17% reduction in electricity use since 2006• 30% gas reduction on boiler projects• 22% reduction in water use• 2 LEED® project certifications• ENERGY STAR Certification for Corporate HQ• 2 Solar installations in the US, 1 in France

Page 9: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

MM Electricity vs. Revenue

17% Drop

Page 10: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Presentation title in footer | 00 Month 000010

Implementing a Sustainable Energy ProgramAn Opportunity—and a Responsibility

Page 11: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Key Elements of Millipore’s Energy Management Program

Page 12: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Energy Improvement Cycle

Measure / Inventory

Capture EnergyCosts and Demand

Conduct EnergyAudits/Pareto

Identify FasterROI Projects

ExecuteScalable Projects

Post-meter

Pre-meter

Page 13: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Areas of Focus – Start with the faster ROI and lower capital projects!

1st Year 2nd Year 3rd Year

•Compressed Air•Lighting•LED Exit signage•Energy Metrics

•Natural Gas•Demand Response•Renewable Energy Credits•Training & Auditing

•On Site Renewable Energy•Building Envelope•Training and Auditing (Level 3)•Products

Page 14: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

1st Step - Energy AssessmentsHired a dedicated resource for auditing in 2009– 9 audits to date.

– Utility demand audits

Continuous Commissioning

Internal Energy Audit SummaryCompletion

Date kWh Goal kWh Savings Identified Installed Cost Cost Savings SPB75 Wiggins, Bedford, MA Jul-09 100,000 74,620 $24,500 $23,006 1.06Danvers, MA Sep-09 200,000 200,698 $85,616 $18,974 4.51Jaffrey, NH Jan-10 1,500,000 1,479,200 $443,000 $198,721 2.23Cork, Ireland May-10 3,000,000 4,864,896 € 333,596 € 259,269 1.29St Charles, MO Aug-10 300,000 384,841 $135,671 $26,169 5.18Kankakee, IL Aug-10 600,000 2,058,171 $171,355 $85,371 2.01Temecula, CA Aug-10 300,000 327,286 $65,488 $35,347 1.85900 Middlesex Turnpike, Billerica, MA Mar-11 350,000 680,016 $48,760 $38,940 1.25Total 6,350,000 10,069,728 $1,374,705.20 $737,650.54 1.86

Page 15: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Auditing Tools

Infrared CameraPurchased an Infrared camera for Bldg Envelope audits.(3) Certified Level One Thermographer Sept 2009.

Electrical metersDevelop run charts & 1st 2nd 3rd levelpareto diagrams to define next opportunities.

Dew point meters for compressed airDiscovered that Desiccant dryers are high energy consumers and not always needed.

Lighting Panel D Warehouse

0

100

200

300

400

500

600

700

11/2

2/20

0811

/23/

2008

11/2

4/20

0811

/25/

2008

11/2

6/20

0811

/27/

2008

11/2

8/20

0811

/29/

2008

11/3

0/20

0812

/1/2

008

12/2

/200

812

/3/2

008

12/4

/200

812

/5/2

008

12/6

/200

812

/7/2

008

12/8

/200

812

/9/2

008

12/1

0/20

0812

/11/

2008

12/1

2/20

0812

/13/

2008

12/1

4/20

0812

/15/

2008

12/1

6/20

0812

/17/

2008

12/1

8/20

0812

/19/

2008

12/2

0/20

0812

/21/

2008

12/2

2/20

0812

/23/

2008

12/2

4/20

0812

/25/

2008

12/2

6/20

0812

/27/

2008

12/2

8/20

0812

/29/

2008

12/3

0/20

0812

/31/

2008

1/1/

2009

1/2/

2009

1/3/

2009

1/4/

2009

1/5/

2009

KW

H U

sed

Page 16: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

WW Energy Management Team meetingsReview Utility consumption regularly

Burlington Distribution Center Electric Consumption

0

50000

100000

150000

200000

250000

300000

Janua

ryFe

bruaryMa

rch April

May

June

July

Augu

stSe

ptemb

erOc

tober

Nove

mber

Decem

ber

Electricity

 Use

 (kWh)

2006 2007 2008 2009 2010 2011

Page 17: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Enterprise Carbon Accounting- Energy Metrics

Page 18: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

EEM Project Implemented – New England2010 Energy Projects Pareto

0

500,000

1,000,000

1,500,000

2,000,000

2,500,000

3,000,000

3,500,000

HVAC CompressedAir

Lighting Motors BuildingEnvelope

Appliance

kWh

Savi

ngs

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

kWh Savings Percentage of Total Savings

Page 19: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

EEM Projects completed 2010 –World Wide2010 kWh Savings by Project Origin

571,46911%

379,0177%

439,6279%

3,749,39473%

MBCx ProjectsInternal EEMExternal EEM (non MBCx)End of Life Replacement

57 Energy Efficiency Measures

Total = 5,139,507 kWh

Net Cost = $559,858

Simple Payback = ~2 years

Page 20: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Presentation title in footer | 00 Month 000020

Success stories in Energy Reduction

Page 21: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Warehouse LightingTo reduce electric load at warehouses, lighting retrofits were performed at 11 locations.

•High-bay metal halide fixtures have been replaced with High Efficient T-5 fluorescent fixtures. •“On” 7 x 24•Individual motion controls with a larger coverage area.

•Warehouse lighting retrofits reduced electric consumption by 1,400,000 kWh /yr = ~ $210,000 per year. •Result in higher quality warehouse lighting which has decreased the product miss-pick rate.

EEM-Energy Efficiency MeasurekWh

SavingsAnnual Cost

Savings Capital CostUtility

Incentive Net Cost with

Incentive Simple

Payback

Warehouse Lighting (11 locations) 1,400,000 $210,000 $410,000 $106,000 $304,000 1.4 years

Metal Halide (400 Watts)80-120 Foot candles

HE T-5 Fluorescent (234 Watts)230 Foot candles

How it works

Results

Page 22: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

AfterMark-6 Controller and EGA

BeforeCleaver-Brooks Controls

Boiler Combustion Improvement Project

Replacement of burners/controls on (2)300 HP Cleaver Brooks Boilers.Autoflame controller provides independent micro modulation of air, fuel valves, and

dampers. (Like Electronic Fuel Injection on your car)EGA- Exhaust Gas Analyzer provides continuous combustion monitoring to the Mark 6

controller. (Like Cruise control on your car)Limpsfield Low O2 Burners replace Cleaver Brooks burner/linkage.

Scope

Projected Results

After 1 full year of Data = 29% gas reductionFuel Savings= 76,428 Therms = 2,239,349 KWhCost Savings= $ 107,000 & GHG Reduction= 382 mTons of CO2

Project Cost= $190,000 with a Utility Incentive= $91,000Simple Payback= 0.9 yr Simple PaybackInstalled (4) additional systems in 09’-standardize all sites in future

Page 23: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Total ~ 2000 HPOr

13,000,000 KWH/yrOr ~ $ 2 Mil/yr

Compressed Air SystemsWorld Wide View

Bedford MA

3=350 HP Rotary Screw

Jaffrey NH4= 600 HP Reciprocating

Molsheim France

7= 400 HP Rotary Screw

Cork Ireland8= 550 HP Rotary Screw

1 HP = $ 1000

Page 24: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Compressed Air Improvement Project

•Meter, Meter, Meter •Flow (CFM)•Power (KWh)•Pressure (PSI)•Dew Pt.

•Leak detection•Study distribution system•Stop inappropriate uses•Study dryer consumption•Install VFD compressors•Monitor the process real time

Scope

Projected Results

•Regular team mtgs to monitor &plan system improvements•Reduced CFM=large KWH savings•Reduced operating pressure 110 to ~90 psi•Defined PM process for leak detection•Stable and consistent delivery of clean dry air to the process

Page 25: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Mobius Clean Room - LEED Gold CertificationInnovative design features to save energy

Particle Counters- Controls Air Handling system to save Energy

Lighting Design- High efficiency T-5 HE lighting with Automatic controls

VLM- Vertical Lift units- product handling saves HVAC energy

Features ENERGY STAR® appliancesMobius Cleanroom Particle Counters

kW vs. Time (8 Weeks)

0

5

10

15

20

25

30

kW

RTU 6 & 7 With Controls RTU 6 & 7 Without Controls

3/29 - 4/2 4/12 - 4/17 4/26 - 5/1 5/10 - 5/15

144,551 kWh / year Savings (motors alone) = 71% Reduction

Page 26: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

After R=22

Before R=1

As a result of a LEED ® Gold Project-Enhanced Commissioning Process detected a building envelope problem above our newly constructed Cleanroom.Infrared Scanning technology demonstrated lack of insulation R=1.Project was developed to upgrade the Building envelope to R=22

Scope

Benefits

Projected Results

Actual Results

Natural gas savings. Reduce emissions.Eliminated a condensation issues above our Cleanroom.

854,235 KWh/yr Savings$45,792 /yr SavingsCost $ 243,833 Simple Payback of 5.1 yrs

This Image shows the conductive heat loss of the concrete roof T’s on the interior side of the roof overhang. Planned future renovations of the exterior façade will eliminate a potential dew point concern on very cold winter days

Building Envelope Project

Page 27: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

LED Parking Lot Lighting- Danvers MA

New LED lighting

48 yr old Sodium Lighting

Replace 48 yr old –(16)sodium light heads with 16 LED

fixtures manufactured by BetaLED

Replacement of light poles was required due to age.

Scope

Benefits

Projected Results

• Reduced electrical consumption• Significantly improved lighting; improved vision and

operator safety• Reduced maintenance costs- ~ 60,000 hrs expected life

• Project Cost: $ 20,500 • $2,175 annual savings• 16,352 Kwh/yr savings• Simple Payback: 9.4 yrs

Page 28: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Isolé Plug Load ControlsMillipore wanted to do more than just “behind closed doors” energy conservation. One step in engaging employees in Millipore’s energy management plan was to install 1,100 plug load controllers into all cubicles.

•Plug Loads are controlled by a motion sensor.•Automatically shuts down of non-critical equipment in each cubicle when vacant. •Each power strip has 6 controlled outlets and 2 continuous power outlets.

•Plug Control project reduces plug load demand by 110,000 kWh /yr = ~ $14,000 per year. •Goal was to implement a unique technology in energy management that engages employees.

EEM-Energy Efficiency MeasurekWh

SavingsAnnual Cost

Savings Capital CostUtility

Incentive Net Cost with

Incentive Simple

Payback

Plug Load Controls - Qty 1100 110,000 $14,300 $80,000 $8,000 $72,000 5.0

How it works

Results

Page 29: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

Solar InstallationBoth projects together represent one the Largest roof mounted Solar PV installations in Massachusetts

Project Launched April 24 - Projected Completed Sept 23, 2009Billerica, MA

•System Size=156 KW •698 Sharp 225 Watt Panels•(2) Solectria Inverters made in MA•Production=175,914 KWh/yr•Gross Cost=$ 1,006,543•MRET & Federal Incentive=$758,997•Net Cost= $247,546

DC

AC to Building

Equal to 7%Consumption

Bedford, MA•System Size=153 KW •685 Sharp 225 Watt Panels•(2) Solectria Inverters made in MA•Production=176,095 KWh/yr•Gross Cost=$ 1,021,612 •MRET & Federal Incentive=$757,470•Net Cost= $264,142

DC

AC to Building

Equal to 4%Consumption

Inverter

Page 30: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss

World Class Energy Management ProgramTraining

What is it all about?Auditing

Areas of opportunityHow to conduct a detailed Energy AuditDiagnostic equipment and planning

MonitoringUtility consumption Analysis

Continuous Improvement -PDCAPlanDoCheckAct

ExecutionDevelop a team to “Sustain” Energy Management Process

Page 31: Energy Efficiency and Renewables Success Stories in …s... · Energy Efficiency and Renewables Success Stories in Energy Reduction ... 500 600 700 11/22/2008 11/23 ... heat loss