Ecotech Natural circulation solar heating system mod. 150-200 mod. 300

Upload: others

Post on 07-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

EcotechNatural circulation solar heating system

mod. 150-200 mod. 300

> THE SIMPLEST WAY TO SOLAR ENERGYCOMPLETE AND VERSATILE SYSTEM

ECOTECHSYSTEMWITH

BOILER SUPPORTIN SERIES

(AS PER THE DIAGRAM)

NO. OF DELIVERY POINTS

(BATHS/SHOWERS)ONLY LIMITED

BY THE OUTPUTOF THE INSTANT BOILER

The brilliance of the Ferroli Group Research and Development Department today makes the simplicity of a natural circulation system perfectly integrated with an instant boiler.

Indeed, Ferroli boilers with the special “SUN EASY” function have advanced electronics that avoid annoying ignition attempts in mid seasons (a problem that is typical of standard boilers), by measuring the domestic water inlet temperature when a solar heating system (e.g. the ECOTECH

natural circulation system) is connected upstream, either in series or as pre-heating.In this way, the boiler only starts when it is really needed.The ECOTECH system represents the simplest approach to solar heating systems.Its high efficiency collectors feature the same careful construction and simple installation as the collectors for

forced systems. The special highly selective vabsorber make sure solar heat is trapped and retained efficiently.Today, solar systems for the production of domestic hot water in residential applications account for the biggest share of the solar thermal market.The versatility of the ECOTECH system for the domestic hot water production makes this a best seller and reason of pride for Ferroli.Choosing ECOTECH means choosing a winning product, one that is perfectly balanced for typical residential uses.The absence of the circulation pump and electronic components ensure maximum reliability.

ECOTECH SYSTEM WITH BOILER SUPPORT IN SERIES

ECOTECH> > > solar division

M

ECOTECH> > > solar division

The solar collector is insulated with high-density rock-wool. The aluminium tray features special ventilation slits to prevent and resolve occasional internal condensate that may occurr naturally when there are considerable temperature swings (e.g. night/day).

All research and developments efforts, together with the advanced design and quality controlchecks let us be extremely confident about the durability of the product, therefore Ferroli cangrant 5 years warranty on these solar collectors.

> QUALITYCARE TO DETAILS

“PEREZ MODEL” FOR ANNUAL RADIATIONEXAMPLE: 30° ANGLE, 45° ORIENTATION, S-W 95% RADIATION

ANNUAL RADIATION IN %

ANGLE OF INCLINATION

DETAIL OF THE CONNECTIONS INSIDE THE COLLECTOR

HYDRAULIC CONNECTION KIT

> ACCESSORIESA RANGE OF FLEXIBLE ACCESSORIES FOR ALL NEEDS

SET OF SUPPORT LEGS FOR BASE FIXING BARS (blue)

SPECIAL P/TDRAIN VALVE

PULL-BAR KIT FOR WINDY AREAS

AUXILIARY ELECTRICAL HEATER

KIT FOR STORAGE MOUNTING BELOW-THE-ROOF

WARRANTY

5 YEARS

> FRAMES AND SUPPORT BARSThe choice of the frames always involves compromises for the installer or reseller. What do you purchase? What do you keep in store? Are the collectors to be installed on flat roofs or sloping roofs? The range of frames for ECOTECH systems resolves these problems before they arise.The solar kit is supplied as standard with the base bars that include the fastening points for the collectors and the storage cylinder.These bars are always used, both on flat roofs and on sloping roofs*.A special set of additional “legs” (these can be ordered when required) transforms the bars into triangular supports suitable for assembly on flat roofs*: et voilà! Problem solved. on sloping roofs; min. slope of the roof: 20°; max slope: 55°. On flat roofs, the angle of the frame legs is 25°.

> BRACKETS FOR SLOPING ROOFS (TILES)A series of brackets is available for fastening the system to different types of tiles:PS: The fastening bars with stud inserts (not self-tapping) are required for the ECOTECH 300 system on all types of tiles/sloping roofs.

> SPECIAL P/T PRESSURE/TEMPERATURE DRAIN VALVEThis is used to limit collector overheating in summer (“stagnation”) if no water is used for several days (e.g. during holidays). This means the solar fluid retains its chemical-physical characteristics longer and less maintenance is needed.The valve is controlled by a device that measures the temperature and pressure, and drains domestic hot water, meaning new cold water is added to the storage cylinder; this in turn cools the solar fluid inside, which when recirculating cools the solar collector.

> PULL-BAR KIT FOR WINDY AREASWind > 26m/sec (100km/h)

> AUXILIARY ELECTRIC HEATERAvailable (as an option) in 2000 Watt versions, with safety thermostat, this heats the storage cylinder on days with less sunlight. (adjustable from 10°C to 70°C)

> THERMOSTATIC MIXEROptional (½”fittings) with settings from 30 to 65°C and max inlet temperature input of 100°C, this device is specifically designed for use with natural circulation systems.

> KIT FOR STORAGE MOUNTING BELOW-THE-ROOFKit for installation of the storage below-the-roof (easier installation and maintenance, better frost protection, no obstrusive storage on the roof, no problem of weight on the tiles, better aesthetic).

ADJUSTABLE GALVANISED STEEL FASTENING SYSTEM FOR MODELS 150

AND 200Suitable for roofs with curved tiles

GALVANISED STEEL FASTENING SYSTEM FOR MODELS 150 AND 200

Suitable for roofs with flat tiles (“Marseille” style)

STAINLESS STEEL FASTENING SYSTEM WITH STUD INSERTS (M12x250 mm) FOR ALL MODELS / STAINLESS STEEL FASTENING

SYSTEM WITH SELF-TAPPING BAR FOR WOOD (M12x120 MIN.) FOR MODELS 150 AND 200

ECOTECH> > > solar division

> ACCESSORIESA RANGE OF FLEXIBLE ACCESSORIES FOR ALL NEEDS

ECOTECH> > > solar division

> TECHNICAL SPECIFICATIONSSUMMARY TABLE - WATER CONNECTIONS

* The protection temperature specified concerns the primary circuit only (water-glycol mix), with the domestic hot water storage cylinder empty. If deciding not to empty the domestic hot water circuit, the electric heater, supplied as an accessory, should be used in frost protection mode. For correct installation, see the manual supplied with the product.

SLOPING ROOFS (20°-55°) 150 200 300Width L 1530 1720 2950Depth P1 2620 2620 2620Heigh H1 (collector + storage tank) 600 600 600

FLAT ROOFS (25°) 150 200 300Width L 1530 1720 2950Depth P 2500 2500 2500Heigh H 1650 1650 1650

KEYA cold water inlet 3/4”B DHW outlet (domestic hot water) 3/4”C return from outer shell - solar circuit (long pipe to the collector) 3/4”D flow to outer shell - solar circuit (short pipe to the collector) 3/4”E socket outlet for pressure relief valveE1 pressure relief valve (3/4” M)F socket outlet for P/T drain valve (1/2” F)F1 socket for pressure-temperature relief valve (optional - anti-

stagnation) 3/4”G magnesium anodeH non-return and 8,5 bar safety valve

MODEL 150 200 300Dimensions (WxLxH) on tilt roof mm 1530x2620x600 1720x2620x600 2950x2620x600Dimensions (WxLxH) on flat roof mm 1530x2500x1650 1720x2500x1650 2950x2500x1650Gross / net useful area (collector/absorber) m2 2,06/1,84 2,06/1,84 4,12/3,68Total weight kg 265 344 465Mounting weight (with empty storage) kg 100 119 185Solar circuit fluid content (including storage) l 15 20 24Nr. of solar collectors (mod. 2.1) nr. 1 1 2Stagnation temperature °C 204,2 204,2 204,2Storage protection (finish) enamelledAbsorber type highly selectiveAbsorption factor (absorber) % 95Emission factor (absorber) % 5Solar collector insulation 40 mm high density mineral wool (rear) and 10 mm (side)Connections of hydraulic circuit (dhw) Ø 3/4”Max operating pressure solar circuit bar 1,8Max operating pressure dhw circuit bar 8,5Max operating temperature dhw circuit °C 90Tank’s catodic protection magnesium anodeAnti-freeze fluid in the kit to be mixed (option) Kg 5 6 8Minimum operating temperature (with empty storage)* °C -10 -10 -10

ECOTECH> > > solar division

ECOTECH> > > solar division

NOTICE FOR DEALERS:As part of its efforts to constantly improve its range of products, with the aim of increasing the level of customer satisfaction, the company stresses that the appearance, dimensions, technical data and accessories may be subject to variation.

Consequently, ensure that the customer is provided with up-to-date technical and/or sales documents.

Cod.

89A

G403

3/02

- 05

.201

7