UK 2894
V(0)a
Issue Date: Valid Until: Reference No:
11 December 2013 28 September 2020 TS1201/0004
Signatory: for
P R Dixon Chief Executive
0135
National Measurement Office | Stanton Avenue | Teddington | TW11 0JZ | United Kingdom Tel +44 (0)20 8943 7272 | Fax +44 (0)20 8943 7270 | Web www.bis.gov.uk/nmo NMO is an Executive Agency of the Department for Business, Innovation & Skills
NAWI Rev. 4 19 February 2013
EC type-approval certificate UK 2894 Revision 5
Issued by:
The National Measurement Office Notified Body Number 0126
In accordance with the requirements of the Non-automatic Weighing Instruments Regulations 2000 (SI 2000/3236) which implement, in the United Kingdom, Council Directive 2009/23/EC, this EC type-approval certificate has been issued to:
CAS Corporation #262, Geurugogae-ro Gwangjeok-myeon Yangju-si Gyeonggi-do Republic of Korea In respect of a single or dual-interval, Class III, non-automatic weighing instrument designated the CL5500 Series, CL5500-D Model and having the following characteristics:
6 kg Maximum capacity 30 kg
e 1 g
n 3000 for Class III instruments with single interval
n 3000 for Class III instruments per partial weighing range, with a maximum of two partial weighing ranges
The necessary data (principal characteristics, alterations, securing, functioning etc) for identification purposes and conditions (when applicable) are set out in the descriptive annex to this certificate.
This revision replaces previous versions of the certificate.
2/12
Descriptive Annex
1 NAME AND TYPE OF INSTRUMENT
This instrument is a CL5500 Series, CL5500-D Model, Class III, mains-operated, self-indicating, price-computing, single or dual-interval, non-automatic weighing instrument (Figure 1). The instrument is designed for direct sales to the public.
2 DESCRIPTION
2.1 Construction
2.1.1 Mechanical
Main features:
Plastic construction
Operator’s keypad (72 PLU Keys + 40 function keys)
Stainless steel load receptor
Pole-mounted double-sided LCD displays (Figure 2)
Level indicator
Integrated printer
2.1.2 Devices
Initial zero setting device (≤ 20% of Max)
Semi-automatic zero setting device (≤ 4% of Max)
Zero tracking device (≤ 4% of Max)
Zero indicator
Net indicator
Stable weight indicator
Semi-automatic subtractive tare balancing device
Preset tare
Gravity compensation
Price-computing
Totalisation (including non-weighed items)
PLU
Fixed weight labelling
Multi-vendor operation
Calibration / set-up mode via sealed internal switch
2.1.3 Load cell
The load cell is a CAS load cell, model TP, capacities as per table 3.2.
2.2 Operation
2.2.1 Switch-on
At switch-on, a display test is performed to ensure that the displays have no defect.
3/12
2.2.2 Zero-tracking
Zero tracking operates provided that the instrument is within range of not more than 4% of its capacity.
2.2.3 Semi-automatic zero setting
The zero button operates provided that the instrument is within range of not more than 4% of its capacity.
2.2.4 Over-range and under-range
If the load is less than gross zero, then the display shows a “-” sign before the value.
The instrument may be set to display weight up to nine divisions above Max. At greater loads the display shows “----”.
2.2.5 Tare
Subtractive tare balancing can be performed, the net indicator is on when a tare is active.
2.2.6 Preset Tare
Preset tare values can be manually entered via the keypad or set up as part of a PLU. The preset tare value is displayed above the net weight, the net indicator is on when a preset tare is active.
2.2.7 Label printing
Labels for weighed items shall indicate the weight, unit-price, price-to-pay and associated units.
Labels for non-weighed items shall indicate the quantity, unit-price, price-to-pay and associated units.
It is permitted to print the net weights without designation, unless a tare or preset tare value is also printed, in which case the net weight should be designated as Net or N.
Labels showing the total price-to-pay shall be clearly identified as such.
Labels printed for voided/returned items shall clearly identify the voided/returned price-to-pay.
3 TECHNICAL DATA
3.1 Power supply
The instrument operates on a 110 to 240 Vac (50/60 Hz) mains power supply.
4/12
3.2 Metrological characteristics
Model CL5500-D
EB 60/150
AP
EB 60/150
AP
EB 60/150
Max (kg) 3 / 6 6 6 / 15 15 15 / 30 30
Min (g) 20 40 40 100 g 100 200
e = (g) 1 / 2 2 2 / 5 5 g 5 / 10 10
T ≤ (kg) -2.999 -6 -5.998 -15 -14.995 -30
Emax (kg) 6 6 15 15 30 30
Note: Emax in the above table refers to the actual measuring range and does not include the dead load for the instrument.
The temperature range for the instrument is -10 °C / +40 °C.
4 PERIPHERAL DEVICES AND INTERFACES
4.1 Interfaces
The instrument may have the following interface type:
RS232C
PS/2
Cash drawer
Ethernet
Wireless LAN
USB
4.2 Peripheral devices
The following peripheral devices may be connected to the interfaces provided:
Peripheral devices that have been issued with a test certificate by a Notified Body responsible for type approval under Directive 2009/23/EC; or
Peripheral devices without a test certificate under the following conditions:
- it bears the CE marking for conformity to the EMC Directive;
- it is not capable of transmitting any data or instruction into the weighing instrument, other than to release a printout, checking for correct data transmission or validation;
- it prints weighing results and other data as received from the weighing instrument without any modification or further processing;
- it complies with the applicable requirements of EN45501, i.e. 4.2, 4.4, 4.6 and 4.7.
A printing device may print additional information such as date or number to identify the printed weighing result(s) or sets of weighing results.
5/12
5 APPROVAL CONDITIONS
This certificate is issued subject to the following conditions:
5.1 Legends and inscriptions
5.1.1 The remote display bears the following legends on or near the display:
Max Min e =
5.1.2 The instrument shall bear the following legends (Figure 3):
Accuracy class CE marking Green M Serial number Manufacturer’s mark or name Certificate number T = - (if T ≠ - Max)
The markings and inscriptions shall fulfil the requirements of Paragraph 1 of Annex IV of the Directive 2009/23/EC.
6 LOCATION OF SEALS AND VERIFICATION MARKS
6.1 The data plate is secured, either by sealing or by being of a form such that it is destroyed when removed.
6.2 Components that may not be dismantled or adjusted by the user must be secured by a wire and seal solution or by a suitable mark placed over the securing screws of the housing (Indicators: Figures 3 and 4). The securing mark may be either:
a mark of the manufacturer and/or manufacturer’s representative, or
an official mark of a verification officer.
Figure 4 shows the sealing of the calibration switch.
6.3 Verification marks, and the CE-marking, are located on, or adjacent to, the data plate situated at the back of the display.
6/12
7 ALTERNATIVES
7.1 Having the instruments manufactured by the following companies:
Shanghai CAS Electronics Co., Ltd. Maixinroad 448, Xinqiaozhen, Songjiangqu, Shanghai, China
CAS Elektronik San. Tic. A.S. Yukari Dudulu, Bostanci Cad. Mevdudi Sokak No: 34 Umraniye-Istanbul / Turkey
CAS (Zhejiang) Electronics Co., Ltd 99# Changjiang Road Jiashan County Zhejiang Province China
7.2 Having a modified construction as shown in Figure 5, with front keyboard (48 PLU Keys + 36 function keys) and operator displays, rear customer displays, and integrated printer. The instrument is designated the CL5500-B and shall be sealed according to Figure 4.
7.3 Having a modified construction as shown in Figure 6, with pole-mounted front keyboard (72 PLU Keys + 36 function keys) and operator displays, pole-mounted rear customer displays, and integrated printer. The instrument is designated the CL5500-P and shall be sealed according to Figure 4.
7.4 Having a modified construction as shown in Figure 7, with pole-mounted front keyboard (72 PLU Keys + 36 function keys) and operator displays, pole-mounted rear customer displays, and integrated printer. The instrument is designated the CL5500-R and shall be sealed according to Figure 4.
7.5 Having a modified construction as shown in Figure 8, with front keyboard (172 PLU Keys + 36 function keys), pole-mounted keyboard and operator displays, pole-mounted rear customer display, and integrated printer. The instrument is designated the CL5500-S and shall be sealed according to Figure 4.
7.6 Having a modified construction as shown in Figure 9, with front keyboard (72 PLU Keys + 36 function keys) and operator displays, rear customer displays, and integrated printer. The instrument is designated the CL5500-H and shall be sealed according to Figure 10.
7.7 Having a modified calibration switch sealing method, as shown in Figure 11.
7/12
8 ILLUSTRATIONS
Figure 1 CL5500-D Series, CL5500-D Model Figure 2 Pole-mounted LCD displays Figure 3 Rating plate Figure 4 Calibration switch sealing method (Models CL5500-D, B, P, R and S) Figure 5 CL5500-B Model Figure 6 CL5500-P Model Figure 7 CL5500-R Model Figure 8 CL5500-S Model Figure 9 CL5500-H Model Figure 10 Calibration switch sealing method (Model CL5500-H) Figure 11 Alternative calibration switch sealing method (Models CL5500-D, B, P,
R and S)
9 CERTIFICATE HISTORY
ISSUE NO. DATE DESCRIPTION
UK 2894 29 September 2010 Type approval first issued.
UK 2894 rev 1 17 August 2011 Authorised alternatives 7.2, 7.3, 7.4, 7.5 and 7.6 added.
UK 2894 rev 2 06 October 2011 Table 3.2 modified to allow different maximum Tare values (≤).
UK 2894 rev 3 06 August 2012 Zhejiang CAS Electronics Co., Ltd. added to section 7.1.
UK 2894 rev 4 02 July 2013 Section 7.7 added.
UK 2894 rev 5 11 December 2013 Applicant’s address on the front page changed from: 19 Ganap-Ri, Gwangjuk-Myoun, Yangji-Si, Gyeonggi-Do 482-841, Republic of Korea
Section 7.1: Zhejiang CAS Electronics Co., Ltd. Building NO.99, Changjiang Road, Huimin Street Jiashan County, Zhejiang Province China Changed to: CAS (Zhejiang) Electronics Co., Ltd 99# Changjiang Road Jiashan County Zhejiang Province China
8/12
Figure 1 CL5500-D Series, CL5500-D Model
Figure 2 Pole-mounted LCD displays
9/12
Figure 3 Rating plate
Figure 4 Calibration switch sealing method (Models CL5500-D, B, P, R and S)
Figure 5 CL5500-B Model
10/12
Figure 6 CL5500-P Model
Figure 7 CL5500-R Model
11/12
Figure 8 CL5500-S Model
Figure 9 CL5500-H Model
12/12
Figure 10 Calibration switch sealing method (Model CL5500-H)
Figure 11 Alternative calibration switch sealing method (Models CL5500-D, B, P, R and S)