ec type-approval certificate uk 2894 revision 5 · uk 2894 rev 2 06 october 2011 table 3.2 modified...

12
UK 2894 V(0)a Issue Date: Valid Until: Reference No: 11 December 2013 28 September 2020 TS1201/0004 Signatory: for P R Dixon Chief Executive 0135 National Measurement Office | Stanton Avenue | Teddington | TW11 0JZ | United Kingdom Tel +44 (0)20 8943 7272 | Fax +44 (0)20 8943 7270 | Web www.bis.gov.uk/nmo NMO is an Executive Agency of the Department for Business, Innovation & Skills NAWI Rev. 4 19 February 2013 EC type-approval certificate UK 2894 Revision 5 Issued by: The National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Non-automatic Weighing Instruments Regulations 2000 (SI 2000/3236) which implement, in the United Kingdom, Council Directive 2009/23/EC, this EC type-approval certificate has been issued to: CAS Corporation #262, Geurugogae-ro Gwangjeok-myeon Yangju-si Gyeonggi-do Republic of Korea In respect of a single or dual-interval, Class III, non-automatic weighing instrument designated the CL5500 Series, CL5500-D Model and having the following characteristics: 6 kg Maximum capacity 30 kg e 1 g n 3000 for Class III instruments with single interval n 3000 for Class III instruments per partial weighing range, with a maximum of two partial weighing ranges The necessary data (principal characteristics, alterations, securing, functioning etc) for identification purposes and conditions (when applicable) are set out in the descriptive annex to this certificate. This revision replaces previous versions of the certificate.

Upload: others

Post on 18-Jan-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EC type-approval certificate UK 2894 Revision 5 · UK 2894 rev 2 06 October 2011 Table 3.2 modified to allow different maximum Tare values (≤). UK 2894 rev 3 06 August 2012 Zhejiang

UK 2894

V(0)a

Issue Date: Valid Until: Reference No:

11 December 2013 28 September 2020 TS1201/0004

Signatory: for

P R Dixon Chief Executive

0135

National Measurement Office | Stanton Avenue | Teddington | TW11 0JZ | United Kingdom Tel +44 (0)20 8943 7272 | Fax +44 (0)20 8943 7270 | Web www.bis.gov.uk/nmo NMO is an Executive Agency of the Department for Business, Innovation & Skills

NAWI Rev. 4 19 February 2013

EC type-approval certificate UK 2894 Revision 5

Issued by:

The National Measurement Office Notified Body Number 0126

In accordance with the requirements of the Non-automatic Weighing Instruments Regulations 2000 (SI 2000/3236) which implement, in the United Kingdom, Council Directive 2009/23/EC, this EC type-approval certificate has been issued to:

CAS Corporation #262, Geurugogae-ro Gwangjeok-myeon Yangju-si Gyeonggi-do Republic of Korea In respect of a single or dual-interval, Class III, non-automatic weighing instrument designated the CL5500 Series, CL5500-D Model and having the following characteristics:

6 kg Maximum capacity 30 kg

e 1 g

n 3000 for Class III instruments with single interval

n 3000 for Class III instruments per partial weighing range, with a maximum of two partial weighing ranges

The necessary data (principal characteristics, alterations, securing, functioning etc) for identification purposes and conditions (when applicable) are set out in the descriptive annex to this certificate.

This revision replaces previous versions of the certificate.

Page 2: EC type-approval certificate UK 2894 Revision 5 · UK 2894 rev 2 06 October 2011 Table 3.2 modified to allow different maximum Tare values (≤). UK 2894 rev 3 06 August 2012 Zhejiang

2/12

Descriptive Annex

1 NAME AND TYPE OF INSTRUMENT

This instrument is a CL5500 Series, CL5500-D Model, Class III, mains-operated, self-indicating, price-computing, single or dual-interval, non-automatic weighing instrument (Figure 1). The instrument is designed for direct sales to the public.

2 DESCRIPTION

2.1 Construction

2.1.1 Mechanical

Main features:

Plastic construction

Operator’s keypad (72 PLU Keys + 40 function keys)

Stainless steel load receptor

Pole-mounted double-sided LCD displays (Figure 2)

Level indicator

Integrated printer

2.1.2 Devices

Initial zero setting device (≤ 20% of Max)

Semi-automatic zero setting device (≤ 4% of Max)

Zero tracking device (≤ 4% of Max)

Zero indicator

Net indicator

Stable weight indicator

Semi-automatic subtractive tare balancing device

Preset tare

Gravity compensation

Price-computing

Totalisation (including non-weighed items)

PLU

Fixed weight labelling

Multi-vendor operation

Calibration / set-up mode via sealed internal switch

2.1.3 Load cell

The load cell is a CAS load cell, model TP, capacities as per table 3.2.

2.2 Operation

2.2.1 Switch-on

At switch-on, a display test is performed to ensure that the displays have no defect.

Page 3: EC type-approval certificate UK 2894 Revision 5 · UK 2894 rev 2 06 October 2011 Table 3.2 modified to allow different maximum Tare values (≤). UK 2894 rev 3 06 August 2012 Zhejiang

3/12

2.2.2 Zero-tracking

Zero tracking operates provided that the instrument is within range of not more than 4% of its capacity.

2.2.3 Semi-automatic zero setting

The zero button operates provided that the instrument is within range of not more than 4% of its capacity.

2.2.4 Over-range and under-range

If the load is less than gross zero, then the display shows a “-” sign before the value.

The instrument may be set to display weight up to nine divisions above Max. At greater loads the display shows “----”.

2.2.5 Tare

Subtractive tare balancing can be performed, the net indicator is on when a tare is active.

2.2.6 Preset Tare

Preset tare values can be manually entered via the keypad or set up as part of a PLU. The preset tare value is displayed above the net weight, the net indicator is on when a preset tare is active.

2.2.7 Label printing

Labels for weighed items shall indicate the weight, unit-price, price-to-pay and associated units.

Labels for non-weighed items shall indicate the quantity, unit-price, price-to-pay and associated units.

It is permitted to print the net weights without designation, unless a tare or preset tare value is also printed, in which case the net weight should be designated as Net or N.

Labels showing the total price-to-pay shall be clearly identified as such.

Labels printed for voided/returned items shall clearly identify the voided/returned price-to-pay.

3 TECHNICAL DATA

3.1 Power supply

The instrument operates on a 110 to 240 Vac (50/60 Hz) mains power supply.

Page 4: EC type-approval certificate UK 2894 Revision 5 · UK 2894 rev 2 06 October 2011 Table 3.2 modified to allow different maximum Tare values (≤). UK 2894 rev 3 06 August 2012 Zhejiang

4/12

3.2 Metrological characteristics

Model CL5500-D

EB 60/150

AP

EB 60/150

AP

EB 60/150

Max (kg) 3 / 6 6 6 / 15 15 15 / 30 30

Min (g) 20 40 40 100 g 100 200

e = (g) 1 / 2 2 2 / 5 5 g 5 / 10 10

T ≤ (kg) -2.999 -6 -5.998 -15 -14.995 -30

Emax (kg) 6 6 15 15 30 30

Note: Emax in the above table refers to the actual measuring range and does not include the dead load for the instrument.

The temperature range for the instrument is -10 °C / +40 °C.

4 PERIPHERAL DEVICES AND INTERFACES

4.1 Interfaces

The instrument may have the following interface type:

RS232C

PS/2

Cash drawer

Ethernet

Wireless LAN

USB

4.2 Peripheral devices

The following peripheral devices may be connected to the interfaces provided:

Peripheral devices that have been issued with a test certificate by a Notified Body responsible for type approval under Directive 2009/23/EC; or

Peripheral devices without a test certificate under the following conditions:

- it bears the CE marking for conformity to the EMC Directive;

- it is not capable of transmitting any data or instruction into the weighing instrument, other than to release a printout, checking for correct data transmission or validation;

- it prints weighing results and other data as received from the weighing instrument without any modification or further processing;

- it complies with the applicable requirements of EN45501, i.e. 4.2, 4.4, 4.6 and 4.7.

A printing device may print additional information such as date or number to identify the printed weighing result(s) or sets of weighing results.

Page 5: EC type-approval certificate UK 2894 Revision 5 · UK 2894 rev 2 06 October 2011 Table 3.2 modified to allow different maximum Tare values (≤). UK 2894 rev 3 06 August 2012 Zhejiang

5/12

5 APPROVAL CONDITIONS

This certificate is issued subject to the following conditions:

5.1 Legends and inscriptions

5.1.1 The remote display bears the following legends on or near the display:

Max Min e =

5.1.2 The instrument shall bear the following legends (Figure 3):

Accuracy class CE marking Green M Serial number Manufacturer’s mark or name Certificate number T = - (if T ≠ - Max)

The markings and inscriptions shall fulfil the requirements of Paragraph 1 of Annex IV of the Directive 2009/23/EC.

6 LOCATION OF SEALS AND VERIFICATION MARKS

6.1 The data plate is secured, either by sealing or by being of a form such that it is destroyed when removed.

6.2 Components that may not be dismantled or adjusted by the user must be secured by a wire and seal solution or by a suitable mark placed over the securing screws of the housing (Indicators: Figures 3 and 4). The securing mark may be either:

a mark of the manufacturer and/or manufacturer’s representative, or

an official mark of a verification officer.

Figure 4 shows the sealing of the calibration switch.

6.3 Verification marks, and the CE-marking, are located on, or adjacent to, the data plate situated at the back of the display.

Page 6: EC type-approval certificate UK 2894 Revision 5 · UK 2894 rev 2 06 October 2011 Table 3.2 modified to allow different maximum Tare values (≤). UK 2894 rev 3 06 August 2012 Zhejiang

6/12

7 ALTERNATIVES

7.1 Having the instruments manufactured by the following companies:

Shanghai CAS Electronics Co., Ltd. Maixinroad 448, Xinqiaozhen, Songjiangqu, Shanghai, China

CAS Elektronik San. Tic. A.S. Yukari Dudulu, Bostanci Cad. Mevdudi Sokak No: 34 Umraniye-Istanbul / Turkey

CAS (Zhejiang) Electronics Co., Ltd 99# Changjiang Road Jiashan County Zhejiang Province China

7.2 Having a modified construction as shown in Figure 5, with front keyboard (48 PLU Keys + 36 function keys) and operator displays, rear customer displays, and integrated printer. The instrument is designated the CL5500-B and shall be sealed according to Figure 4.

7.3 Having a modified construction as shown in Figure 6, with pole-mounted front keyboard (72 PLU Keys + 36 function keys) and operator displays, pole-mounted rear customer displays, and integrated printer. The instrument is designated the CL5500-P and shall be sealed according to Figure 4.

7.4 Having a modified construction as shown in Figure 7, with pole-mounted front keyboard (72 PLU Keys + 36 function keys) and operator displays, pole-mounted rear customer displays, and integrated printer. The instrument is designated the CL5500-R and shall be sealed according to Figure 4.

7.5 Having a modified construction as shown in Figure 8, with front keyboard (172 PLU Keys + 36 function keys), pole-mounted keyboard and operator displays, pole-mounted rear customer display, and integrated printer. The instrument is designated the CL5500-S and shall be sealed according to Figure 4.

7.6 Having a modified construction as shown in Figure 9, with front keyboard (72 PLU Keys + 36 function keys) and operator displays, rear customer displays, and integrated printer. The instrument is designated the CL5500-H and shall be sealed according to Figure 10.

7.7 Having a modified calibration switch sealing method, as shown in Figure 11.

Page 7: EC type-approval certificate UK 2894 Revision 5 · UK 2894 rev 2 06 October 2011 Table 3.2 modified to allow different maximum Tare values (≤). UK 2894 rev 3 06 August 2012 Zhejiang

7/12

8 ILLUSTRATIONS

Figure 1 CL5500-D Series, CL5500-D Model Figure 2 Pole-mounted LCD displays Figure 3 Rating plate Figure 4 Calibration switch sealing method (Models CL5500-D, B, P, R and S) Figure 5 CL5500-B Model Figure 6 CL5500-P Model Figure 7 CL5500-R Model Figure 8 CL5500-S Model Figure 9 CL5500-H Model Figure 10 Calibration switch sealing method (Model CL5500-H) Figure 11 Alternative calibration switch sealing method (Models CL5500-D, B, P,

R and S)

9 CERTIFICATE HISTORY

ISSUE NO. DATE DESCRIPTION

UK 2894 29 September 2010 Type approval first issued.

UK 2894 rev 1 17 August 2011 Authorised alternatives 7.2, 7.3, 7.4, 7.5 and 7.6 added.

UK 2894 rev 2 06 October 2011 Table 3.2 modified to allow different maximum Tare values (≤).

UK 2894 rev 3 06 August 2012 Zhejiang CAS Electronics Co., Ltd. added to section 7.1.

UK 2894 rev 4 02 July 2013 Section 7.7 added.

UK 2894 rev 5 11 December 2013 Applicant’s address on the front page changed from: 19 Ganap-Ri, Gwangjuk-Myoun, Yangji-Si, Gyeonggi-Do 482-841, Republic of Korea

Section 7.1: Zhejiang CAS Electronics Co., Ltd. Building NO.99, Changjiang Road, Huimin Street Jiashan County, Zhejiang Province China Changed to: CAS (Zhejiang) Electronics Co., Ltd 99# Changjiang Road Jiashan County Zhejiang Province China

Page 8: EC type-approval certificate UK 2894 Revision 5 · UK 2894 rev 2 06 October 2011 Table 3.2 modified to allow different maximum Tare values (≤). UK 2894 rev 3 06 August 2012 Zhejiang

8/12

Figure 1 CL5500-D Series, CL5500-D Model

Figure 2 Pole-mounted LCD displays

Page 9: EC type-approval certificate UK 2894 Revision 5 · UK 2894 rev 2 06 October 2011 Table 3.2 modified to allow different maximum Tare values (≤). UK 2894 rev 3 06 August 2012 Zhejiang

9/12

Figure 3 Rating plate

Figure 4 Calibration switch sealing method (Models CL5500-D, B, P, R and S)

Figure 5 CL5500-B Model

Page 10: EC type-approval certificate UK 2894 Revision 5 · UK 2894 rev 2 06 October 2011 Table 3.2 modified to allow different maximum Tare values (≤). UK 2894 rev 3 06 August 2012 Zhejiang

10/12

Figure 6 CL5500-P Model

Figure 7 CL5500-R Model

Page 11: EC type-approval certificate UK 2894 Revision 5 · UK 2894 rev 2 06 October 2011 Table 3.2 modified to allow different maximum Tare values (≤). UK 2894 rev 3 06 August 2012 Zhejiang

11/12

Figure 8 CL5500-S Model

Figure 9 CL5500-H Model

Page 12: EC type-approval certificate UK 2894 Revision 5 · UK 2894 rev 2 06 October 2011 Table 3.2 modified to allow different maximum Tare values (≤). UK 2894 rev 3 06 August 2012 Zhejiang

12/12

Figure 10 Calibration switch sealing method (Model CL5500-H)

Figure 11 Alternative calibration switch sealing method (Models CL5500-D, B, P, R and S)

© Crown Copyright 2013 NATIONAL MEASUREMENT OFFICE Department for Business, Innovation & Skills