  • ALTERNADOR FG WILSON

  • Lista de partes

    No.

    Nbr.

    Description

    No.

    Nbr.

    Description

    1

    1

    Stator assembly

    107

    1

    Support diode assembly

    4

    1

    Rotor assembly

    124

    1

    Terminal plate

    15

    1

    Fan

    198

    1

    Regulator(AVR)

    16

    6

    Fan fixing screw

    207

    1

    Rubber

    28

    1

    Earth terminal

    290

    1

    Housing

    30

    1

    DE flange

    291

    1

    Adaptation shaft

    33

    1

    Air outlet louvre

    292

    1

    Rotor magnets

    36

    1

    N.D.E.bracket

    293

    1

    Stator

    37

    4

    Tie rod

    294

    2

    Fixing screw

    41

    1

    D.E.terminal box

    295

    1

    Tie rod

    47

    1

    N.D.E.terminal box

    296

    1

    Washer & nut

    48

    1

    Terminal box lid

    297

    1

    End plate

    49

    20

    Terminal box fixing screw

    320

    1

    Hub

    51

    1

    Air intake louvre

    322

    1

    Coupling disc

    59

    3

    Inspection door

    323

    Fixing screw

    70

    1

    NDE bearing

    324

    1

    Clamping washer

    79

    1

    Preloading wavy washer

    325

    Spacer shim

    90

    1

    Wound exciter field

    343

    1

    Diode bridge assembly

    91

    4

    Field fixing screw

    347

    1

    Surge suppressor Varistor

    98

    3

    Corner plate

    349

    1

    O ring seal

    100

    1

    Exciter armature

  • Rotulado del alternadorL L 2 0 1 4 HFabricante:L = Leroy SomerMotor:L= PerkinsA = Lister 3 Phase B = Lister 1 PhaseSerie de alternador:1 = 10002 = 2000etc.Emisin:0 = primeraExcitacin:1 = Shunt2 = AREP3 = PMGNumero de polosLongitud

  • ESPECIFICACIONES DE MODELO DE ALTERNADOR Genset Alternador 30 KVA LL1014Q 44 KVA LL2014B 50 KVA LL2014D 65 KVA LL2014H 77 KVA LL2014J 100 KVA LL3014B 110 KVA LL3014B 150 KVA LL3014F

  • ESPECIFICACIONES DE MODELO DE ALTERNADOR Genset Alternador 175 KVA LL3014H 188 KVA LL3014H 200 KVA LL5014F

  • Como trabaja un alternador?

    L1L2L3N

  • PRINCIPIO DEL ALTERNADORBOBINADO DEL ESTATORBOBINADO DEL ROTOR

  • PRINCIPIO DEL ALTERNADORBobinado del estatorCorriente alternaCorriente continuaBobinado del rotorRectificadoresCampo de exitacin

  • PRINCIPIO DEL SHUNTAVRBobinado del estatorCorriente alternaCorriente continuaBobinado del rotorRectificadoresCampo de exitacin

  • PRINCIPIO DE SHUNT + PMGA.V.R.P.M.G.Bobinado del estatorCorriente alternaCorriente continuaBobinado del rotorRectificadoresCampo de exitacin

  • PMG

    290 Housing

    291 Adaptation shaft

    292 Rotor magnets

    293 Stator

    294 Fixing screw

    295 Tie rod

    296 Washer & nut

    297 End plate

  • P M GConexin PMG (AVR)/ R4492000-3000 SeriesPMG/AREP EXCITATIONSHUNTConexin en serieConexin en paraleloCampo de exitacinCampo de exitacinCampo de exitacin5+6-5+6-

  • PRINCIPIO AREPAVRBobinado del estatorCorriente alternaCorriente continuaBobinado del rotorRectificadoresCampo de exitacin

  • SISTEMAS DE EXITACINSHUNT + PMGAREPSHUNTVentajasDesventajasAlta capacidad de arranqueCapacidad de cortocircuitoAlta capacidad dearranqueCapacidad de cortocircuitoAutoproteccin antecortocircuitoAumento de tamaoAlta cantidad de componentesBaja capacidad de arranqueNo admite cortocircuitoSensible a la distorsionde carga si es concontrol por tiristorAumento intrnsecoSin aumento de tamaoSin aumento de tamaoPequeo sobreprecioPequeo sobreprecioBobinado especfico

  • CARACTERISTICAS DE SOBRECARGA

    VOLTAGE (V)LOAD %300%100%200%AREP/ PMGAREP SERIES CHARACTERISTIC( Auxiliary winding H3/ AREP)SHUNT( or auxiliary winding H1/ AREP)SUSTAINEDVOLTAGE DIPU NBAJA SOBRECARGAALTA SOBRECARGA - CORTOCIRCUITOSHUNTAREP

  • Excitacin: Series & AVR.Autoexitado ( Shunt ): 1000,2000,3000, Series AVR R230A o opcional AVR R4485000, 6000 Series AVR R4488100,9100 Series AVR 449

    PMG :1000 Series no disponible2000,3000 Series AVR R4385000,6000,7000 Series AVR R4488100,9100 Series AVR R449

    AREP :1000,2000,3000 Series AVR R4385000,6000,7000 Series AVR R448 8000,9000 Series AVR R449

    Todos los AVRs poseen regulacin de voltaje de +/- 0.5%.

  • Los 4 tipos de AVR LeroyR438R448 & R449R230

  • Ajuste de voltajeAVR R 250Sensor de voltajePotenciometro externoAjuste de estabilidadfusible50/60Hz

  • AVR R 230

  • Ajuste para paralelismoAjuste de estabilidadCARACTERISTICAS DEL AVR R 438Seleccin de respuesta de tiempoTransformador de aislacinConector secundario para expansiones- sensado de tres fases- paralelismoAjuste de voltaje 5%3 de deteccin de voltajede 95 a 520 V - 1 o 2 fasesFusibleSeleccin de LAM50/60HzExitacin de mxima corriente y ajuste nivel de S/CProteccin por baja velocidad

  • AVR R 438

  • REGULADOR DE VOLTAJE R 438R 791 E.M.I. suppressorC.T. for parallel operationbetween gensetsR 726 Paralleling with mains3 functions R 731 sensado de 3 fasesRhe remote voltage trimmerOptional modules

  • DROOP ADJUSTMENTFOR ALTERNATORPARALLELINGSTABILITY ADJUSTMENTCARACTERSTICAS DEL AVRAREP/SHUNT/PMG EXCITATION R 448 & 449RESPONSE TIME SELECTIONAvoids speed oscillation of theengineISOLATINGTRANSFORMERSECONDARY CONNECTORFOR EXTENSION MODULES- three phase sensing- parallelingVOLTAGE ADJUSTMENT 5%3 POSSIBILITIES OF VOLTAGE DETECTIONfrom 95 to 520 V - 1 or 2 PH sensingFUSELAM SELECTION50/60Hz CONNECTIONMAXIMUM EXCITATION CURRENT & S/C LEVEL ADJUSTMENTLOW SPEED PROTECTION & LAM

  • AVR R 448 & 449R 448&449

  • REGULADORES DE VOLTAJE R 448 & 449R 726 Paralelismo con 3 funciones principalesRhe Ajuste remoto de voltajeMdulos opcionales R 731 Sensado trifasicoC.T. para operacion en palaeloentre generadoresR 791 suppresor E.M.I.

  • Aceptacin de cargaR 438 / R 448 / R 449 con exitacin AREPSituacion : 100 % de carga es aplicada al generadorCURRENT El motor se detiene No aceptacin de carga del mdulo100 % cargaSpeed or frequencySpeed or frequency El motor no se detiene Aceptacin de carga del mdulo

  • GENERATOR SETS RATINGSCOP: SERVICIO CONTINUO ( CONTINUOUS POWER ) Funcionamiento continuo a carga constante nominal. Nmero ilimitado de horas/ao. Cogeneracin / Marino.... Alternador rating S1/40 C- clase H o F. PRP: SERVICIO PRIME ( PRIME POWER ) Funcionamiento continuo a carga inconstante Nmero ilimitado de horas/ao. Industria- Trabajo pblicos...... Alternador rating S1/ 40 C- clase H. Capacidad de carga. LTP: LIMITE DE TIEMPO DE FUNCIONAMIENTO- STAND BY ( EMERGENCIA ) Lo mximo tasado permitido es de 500 horas/ao. ( Con un mximo de 300 horas de funcionamiento continuo ) Alternador rating stand-by duty 27 C.

  • FRECUENCIAFREQUENCIA : (Hz) = velocidad (min -1) x N (numero de polos) 120

    FRECUENCIAS PRINCIPALES :

    50 Hz : EUROPA, AFRICA, PARTE DE ASIA, PARTE DE SUD AMERICA.

    60 Hz : NORTE AMERICA, PARTE DE ASIA, PARTE DE SUD AMERICA.

    400Hz : AEROPUERTOS

  • VELOCIDAD DEL ALTERNADORPOLOS 2P4P6P8P10P12P14P16P

    50 Hz300015001000750600500428375

    60 Hz360018001200900720600514450VELOCIDAD EN MN -1 OR R.P.M. DIRECCIN DE ROTACIN

    STANDARD : SENTIDO HORARIO VISTO DESDE EL EJE DE MANDO

  • FACTOR DE POTENCIAkW = POTENCIA ACTIVA (REAL)kVA = POTENCIA ( APPARENT)kV AR = POTENCIA REACTIVA ( REACTIVE )INDUCTIVE P.F. = INDUCTIVE LOAD, ISYNCHRONOUS MOTOR, TRANSFORMER ... (CURRENT LAGS THE VOLTAGE)CAPACITIVE POWER FACTOR : FLUORESCENT LIGHT, CAPACITOR ...(CURRENT LEADS THE VOLTAGE)CAPACITIVEINDUCTIVEkVAkVkWAR

  • SOBRECARGASOBRECARGAAUMENTO DE LA TEMPERATURASOBRECARGAS PERMITIDASDURACIN1H30155230103

    SOBRECARGA10%11%14%25%50%100%200%S.C, 3 PHCada marcha con sobrecarga debera ser seguida por 1 hora con carganominal o 10 minutos sin carga

  • VOLTAJE Mquinas con 12 conexiones accesiblesEjemplo: STANDARD WINDING N 6 - 3 PHASE/ 2/3 PITCH.Conexin serie en estrella conexin paralelo en estrella

  • VOLTAJE Mquinas con 12 conexiones accesiblesEjemplo: STANDARD WINDING N 6 - 3 PHASE/ 2/3 PITCH.Conexin tringulo serie Conexin tringulo paralelo

  • VOLTAJE Mquinas con 12 conexiones accesiblesEjemplo: STANDARD WINDING N 6 - SINGLE PHASE(FF)CONNEXION ZIG - ZAG (G)( NO RECOMENDADA)

  • Falta de fase en el estator10080140L1

    L2

    L3L1

    L2

    L3120120120L1

    L2

    L37010090

  • Falta de fase en el estator y en el AVR.ALTERNATINGCURRENTDIRECTCURRENT

  • Testeando los diodosMULTIMETROMULTIMETROMayor que 10,000 OHMSMenor que100 OHMS

  • Resistencia del rotor usando una batera de 6 volts6V+_Multimetro en rango 10ampResistencia de rotor = 6 AMPS

  • Test de aislacin1.Resistencia mnima aceptable a tierra = 1 Mohm2.El AVR debe ser desconectado al megar los bobinados

    3.Megar:- Estator principal Rotor principal Estator de exitacin Rotor de exitacin

    El megado es necesario si el generador se ha humedecido o ha permanecido Sin uso por largo tiempoUsar tester de 500V de aislacin

  • Partes de reemplazo

  • Consideraciones por causas climticas