d meltem mwrg broschuere print 2013

29
You can relax. We’ll bring back the WARMTH COMFORT HOME VENTILATION WITH HEAT RECOVERY M-WRG VENTILATION THE RIGHT WAY VENTILATION AND HEAT RECOVERY

Upload: alina-voinea

Post on 02-Jun-2018

221 views

Category:

Documents


0 download

TRANSCRIPT

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 1/28

You can relax.We’ll bring backthe WARMTH 

COMFORT HOME VENTILATION WITH HEAT RECOVERY

M-WRG

VENTILATION THE RIGHT WAY

VENTILATION AND HEAT RECOVERY

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 2/28

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 3/28

VENTILATION AND HEAT RECOVERY

  3

SMART VENTILATIONwith heat recovery

An investment in a comfort ventilation

system with heat recovery will definitely

pay dividends. Individual room ventilation

provides for comfort, noise reduction,

the removal of stale air as well as for a

hypoallergenic environment. And meets the

standards for low-energy houses as well.

Thus, the M-WRG system is the smart choice

for those who love fresh-air and are conscious

about the use of energy and the environment.

HEALTHY LIVING

• Wellness through clean and

pre-heated fresh air

• Hypoallergenic due to

high-performance filters

• no draughts

  CONSERVE ENERGY

• Save on heating costs and

reduction of CO2 - emissions

• Extremely low power consumption

• Low-energy home (efficient home

according to the Reconstruction LoanCorporation (KfW) can be achieved

at a low cost

  MOISTURE PROTECTION

• Protection against moisture damage

• Prevention of mould growth• Securing the structure

  NOISE PROTECTION

• Ventilation without outside noise

• High level of sound insulation• Virtually noiseless operation

(thus well-suited for bedrooms)

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 4/28

4 VENTILATION THE RIGHT WAY

A H E A L T H I E R L I V I N G E N V I R O N M E N T

M-WRG

Fresh air means more quality of life. It

ensures that people feel well in their homes.

Increased concentrations of CO2 can lead

to fatigue, headaches, lack of concentration

and decrease in performance. Vapours from

cleaning agents, building materials, carpets,

furniture, etc. contaminate the air we breathe

with additional pollutants. Thus, proper

ventilation is necessary for a healthy home.

QUALITY OF LIFE IN SPITE OF

ALLERGIES 

Many suffer from allergies caused by

dust or pollen. With our ventilation

products, you can keep these

allergens outside – as such, the quality of the

filter being used is crucial. The G4 standard

filter filters out most of the pollen and dust.

An F7 allergy filter, which additionally blocks

most bacteria, is available for higher levels

of contamination. The activated carbon filter

should be used to prevent unpleasant odours

and harmful gasses. For their hypoallergenic

qualities, the European Centre for Allergy

Research Foundation (ECARF) at the Charité

University Hospital in Berlin awarded our

ventilation devices the ECARF Quality Seal.

By choosing a Meltem home ventilation

system with heat recovery, you will be able

to create a healthy indoor environment

and a higher quality of life in your

own home. Turn your home into your

personal atmospheric health spa.Seal of Quality

Hypoallergenic

product

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 5/28

VENTILATION AND HEAT RECOVERY

  5

ALL-ROUNDVentilation with Individual

Units

Our basic unit, M-WRG-S, provides a range

of functionality and a maximum level of

performance:

• Almost noiseless operation

• High level of heat recovery

• Minimum power consumption

• Airflow can be adjusted from

15 to 100 m3/h

• Boost ventilation mode (30 minutes,

100 m3/h)

• Separate filter for supply and exhaust air

• Change filter indicator

• Anti-freeze protection

• Fully automatic air flap control

• Wide range of user options

Choosing a M-WRG-K comfort unit enables

convenient control via an infrared remote

control and alphanumeric display. The

M-WRG-K/LCD unit has an LCD display and

keyboard. Various basic programmes can be

set per menu selection for both units to con-

trol humidity, CO2, time and temperature

programmes as well as individual supply

and exhaust air control (operation during

the summer).

The ventilation unit M-WRG-K/ZNH  also

features electronic supply air warming.

M-WRG-K Comfort Unit

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 6/28

6 VENTILATION THE RIGHT WAY

E N E R G Y - E F F I C I E N C Y

SMARTventilation means saving energy.

PROPER VENTILATION SAVES

MONEY

Today, energy conservation is just a given and

enormous amounts of money are invested

in the insulation of roofs, façades and win-

dows. The shell of a building is constantly be-

coming more airtight through the increased

demands for energy efficiency (EnEV)

and must be ventilated regularly to pre-

vent moisture damage and the growth of

mould. Thus, home ventilation with heat

recovery is indispensibleindispensable.

The currently still most widely practiced

window ventilation is – at least from the per-

spective of energy – completely insufficient.

Up to 50% of the heat energy is lost through

window ventilation. What sense does it

make to literally “heat the outside of your

home” in spite of the energy saved through

costly insulation?

By opting for a controlled home ventilation

system with heat recovery from Meltem, you

will retrieve most of this lost energy – and all

that while consuming less power: For every

consumed kilowatt hour of electricity, an

M-WRG unit will retrieve 22 kilowatt hours

of heat energy from the exhaust air!

According  to K f  W 

Guidelines eligible  f or 

go vernmen t suppor t.

wallapprox. 15%

Roof approx. 10%

+ventilationapprox. 50%

windowapprox. 20%

Basement

approx. 5%

average

heat loss in %

20

15

10

5

0

-5

-10

+23°

+19°

+15.5°

+11.5°

+7.5°

Outside temperature

Temperature increasethrough M-WRG

The lower the outside temperature is,the more effectively the heat of theM-WRG units is recovered.

Supply air temperatures forvarious outside temperatures

Basis of the calculation is a room temperature of 20°C and a degree of heat provisioning 76%.

°C

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 7/28

VENTILATION AND HEAT RECOVERY

  7

V E N T I L A T I O N A T H O M E

1

1

2

3

2

M-WRG ventilation unit

Façade finish

Button sensor InControl M-WRG-T/WS-ES-AL

2

3

1

3

2

2

1

HOW CAN THE M-WRG

VENTILATION TECHNOLOGY

BE INSTALLED IN MY HOME?

The decentralised home ventilation with

heat recovery from Meltem automatically

provides for the proper ventilation in the

home. The ventilation units are mounted

on the inside of an exterior wall. Two pipes

for supply air and exhaust air are directed

to the outside through the wall. The pipes

are covered on the exterior façade with

stainless steel finishes. Space-consuming

and expensive pipes with noise dampers,

such as with a central system, are therefore

not necessary, which makes the installation

significantly faster and easier.

The number of units of the required devices

depends on the number and area of the

rooms to be ventilated as well as the number

of people. Larger rooms (approx. 40m2)can

be ventilated with one unit due to its high

air throughput. The units can be used in all

rooms, even in kitchens, bathrooms or WCs.

A second room can be easily connected via a

flat ventilation duct.

The user can set the desired ventilation level

for each room individually either directly on

the unit or with a remote control.

CO2

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 8/28

8 VENTILATION THE RIGHT WAY

I N D I V I D U A L C O N T R O L

INDIVIDUALLY customised to your needs

You can set and run the Meltem M-WRG

ventilation units according to your needs.

They are available in the Standard, Comfort,

and as the particularly flexible Network

version. We offer you a broad range of

individual operating options, which extend

from the direct operation on the unit to

central operation via touch screen.

CONTROL BASED ON YOUR NEEDS

FOR MAXIMAL ENERGY SAVINGS

You can achieve the most efficient and

energy conserving operation with a

humidity and room air quality (CO2)

controller that is adjustable to your

needs. An integrated microprocessor

calculated the optimal air exchange rate

from the measured values of the humidity

and CO2 sensors and automatically adjusts

the proper ventilation level. Thus, ventilation

only occurs to the extent actually necessary.

Picture Living by Hoflehner

Picture pabneu

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 9/28

VENTILATION AND HEAT RECOVERY

  9

MULTIFACETED CONTROL OPTIONS

M-WRG-S M-WRG-S/Z-S (T)

stage selector switch

the unit, temporally

icted boost ventilation

Connector for the3-stage selector switch

(+ button switch forboost ventilation) or six-fold

Button with LED display

M-WRG-S/BM

230 V signal input for the

external switch,

motion sensor or timer 

EASY TO USE

You can comfortably control the ventilation

units remotely with the M-WRG-HBE function

controller. Five ventilation stages, supply

air and exhaust air operation as well as –

depending on the chosen model – the control

of air humidity and quality of the inside air

can be set. At the push of a button, you can

conduct a 30 minute boost ventilation with

an air throughput flow of 100 m3/h. A light-

emitting diode respectively shows the current

operational status in various colours.

M-WRG-S/Z-A

Function controller 

M-WRG-HBE

for up to 5 units

Function controller M-WRG-HBE

M-WRG-K

Alphanumerical

display on the unit and

infrared remote control

Graphical display

and keyboard

on the unit

Connection to

a

EIB/KNX bus

M-WRG-K/LCDM-WRG-S/Z-EIB/KNX

EIB/KNX bus

ictures: pabneu

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 10/28

10 VENTILATION THE RIGHT WAY

C U S T O M I S E D C O N T R O L O F A S I N G L E - F A M I L Y H O M EU P T O L A R G E P R O P E R T I E S

A CENTRAL CONTROL UNIT OFFERS

THE HIGH LEVEL OF CONTROL

COMFORT

The Meltem M-WRG-S485 network solution

is the first choice for large buildings with

several ventilation units. Up to 250 M-WRG

units can be centrally controlled with thisnetwork solution via a computer. It clear,

graphical user interface (touch screen)

visualises all relevant data in the building and

enables a simplified user input. The control

system provides individual ventilation

room for room. Controlling the humidity or

CO2 content of the inside air as needed is

likewise possible, such as freely adjustable

timer programmes, e. g. for operation

during the summer, winter, holiday periods

or on weekends.

• Individual possibilities for control

individual units, unit groups or the entireventilation system

• Up-to-date information notifications

(operational status, temperature, antifreeze

protection, filter replacement, etc.)

• Clear graphical display for visualising the

operational conditions and for the simple

input of control commands through pre-

defined input fields on the touch screen

Controlvia standard PC(touch screen)

Control andremote maintenance are

possible viathe internet

A GIANTin Performance & Flexibility

up to 250M-WRG-S-485

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 11/28

VENTILATION AND HEAT RECOVERY

  11

FRESH AIR FOR

SENSITIVE AREAS

There is virtually no area that may not

be professionally ventilated. Meltem

ventilation units provide draught-free, fresh

air even in sensitive public buildings at low

energy and operational costs. Whether in

schools, hospitals, and nursing homes or in

commercial buildings – the highly-advanced

ventilation technology can provide more

comfort through fresh, clean air.

It is absolutely obvious: Hospitals have

other needs than private households with

regard to their ventilation technology.

For example, Meltem ventilation systems

provide neonatal and infant units  at the

hospital in Weiden with draught-free, pre-

heated fresh air.

Another variation is provided through

the possibility of connecting to a modern

building control system (EIB/KNX,...).

School in Waldburg:Installation of the M-WRG units in thewindow sill

Weiden Clinic, Neonatal Unit

Idea l  f or sc hoo ls, 

nurs ing  homes,  ho te ls....

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 12/28

12 VENTILATION THE RIGHT WAY

H I G H - T E C H M A D E I N G E R M A N Y

G4 standard filter

PERFECTIONin functionality & technology

F7 allergy filter

M6 activated carbon filter

HOW DOES THE M-WRG

VENTILATION TECHNOLOGY WORK? 

Stale air is removed from the rooms with

a ventilator and fed to the heat exchanger* 

already filtered. A second ventilator draws in

filtered fresh air from outside and directs it

to the heat exchanger as well. At this point,

the stale air and the fresh air pass by each

other in a cross-flow separated through the

aluminium plates. In this process, the heat

from the warm exhaust air is transferred

to the cold fresh air. The cooled, stale air is

directed outside and the warmed fresh air

flows draught-free into the living space.

H I G H - P E R F O R M A N C E

F I L T E R S

We have placed particular significance on the

filter technology. Only a high-performance

filter can safely protect people and the

rooms to be ventilated against polluting

environmental factors, such as dust, debris,

pollen or insects.

Our M-WRG units use Class G-4 high-

performance filters for supply air and

exhaust air. The large surface (0.36  m2)

allows for long intervals between filter

replacements. Alternatively, you can also

insert an F7 hypoallergenic filter, which will

also retain most bacteria due to its finer filter

insert. In the case of unpleasant odours or

harmful gasses (such as greenhouse gasses,

nitrogen oxide, etc.), we recommend using

the M6 activated carbon filter .

* cross-current plate heat exchanger Quicker and c leaner  fi l ter

rep lacemen t  wi thou t  too ls

Innenbereich   Außenbereich

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 13/28

VENTILATION AND HEAT RECOVERY

  13

Exhaust air filterHousing

Supply air filter

Heat exchanger

Condensation drainage

Exhaust air fan

Supply air fan

Power terminal

On/Off switch

H I G H A I R T H R O U G H P U T

Two radial fans are used to ensure a high

air throughput even under unfavourable

pressure conditions (for example, due

to wind). They are powered by high-

performance and energy-efficient DC

motors. Motors and the unit itself are

controlled by the most advanced electronics,

which ensure that your M-WRG unit is not

only extremely efficient, but also performs

well. At the same time, the units are virtually

noiseless, wherefore they can be used in

bedrooms without a problem.

The M-WRG units have an automatic

antifreeze protection that reliably prevents

the heat exchanger from freezing with

outside temperatures below zero degrees

and guarantees stable operation. When

turning off the unit or in the case of

blackouts, the air flaps are automatically

closed in order to prevent draughts and the

uncontrolled inflow of cold air.

All components are designed to have long-

lasting life cycles additionally through the use

of corrosion-resistant materials.

All M-WRG units are officially certified (TÜV)

and approved by the German Institute for

Civil Engineering.

Electronics

Stage 1

Stage 2

Stage 3

Boostventilation

Microprocessors enable high

performance and efficient power

consumption

Steep pressure-volume

characteristic curve

Quality madein Germany

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 14/28

14 VENTILATION THE RIGHT WAY

I N S T A L L A T I O N O P T I O N S

visible façade finish with stainless steel pod

Meltem-M-WRG ventilation units can be

integrated into the home or building in a

variety of ways. The devices are mounted on

the inside of an exterior wall. The best effect

for comfort and energy efficiency is achieved

if they are attached to the upper third of thewall; however, a minimum distance of 15 cm

from the ceiling should be maintained. The

system can be surface-mounted or flush-

mounted. The flush-mounted installation

is achieved through the flush-mounting

installation kit. In the case of surface-

mounting, only two core drill holes in the

wall are required. This is particularly well-

suited in the area of renovation.

Through the use of a ductwork adaptor,

the unit can ventilate a second room (e.g.

bedroom and bath, bedroom and closet,

etc.) via a flat duct.

SIMPLE INSTALLATION AND PLANNING:• Installation of the standardised

units is conceivably simple

• Surface-mounted or flush-mounted

installation possible

• No expensive laying of pipes

with noise dampers and control valves

  /flaps necessary

• No condensation drain pipe

necessary

• Possible to easily retrofit without

having to do work on the walls

V A R I A B L E I N S T A L L A T I O N O P T I O N S

SIMPLYquick to install

Flush-mountedinstallation

Surface-mountedinstallation

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 15/28

VENTILATION AND HEAT RECOVERY

  15

Covered façade finish through window embrasure solution

As a special accessory for those who are design-

conscious, we offer trendy design covers for ourventilation units upon request. Thus, you can be creative

and give your home a distinctive individual note.

 c r e a t e  y o u r  d e s i g n

 Individual

DESIGN for fresh air

 AT HOME!

N E W :   D E S I G N C O V E R S

In addition to the visible façade finish with a small pod, a concealed

façade finish in the window embrasure is also possible in order to

meet even the most rigid architectonic demands. With this solution,

instead of the pod on the façade, extremely discrete outlets are

installed in the window sill, which are finished with an

elegant stainless steel faceplate.

1

1

Detail: Window embrasure solution

 

Picture frameblack or white

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 16/28

16 VENTILATION THE RIGHT WAY

M-WRG Product Line

Article Diagram Type Description

STANDARD UNIT

Ventilation units with heat recovery, white, impact resistant ABS plastic housing,aluminium cross-current plate heat exchanger, electronic control, 2 G4 air filter, antifreeze protection, acoustic filter replacementnotification, fully automatic air flap control. All units are certified (TÜV) and approved by the building authority. (Z-5 1.3-138)

STANDARD UNITS (THREE VENTILATION LEVELS TEMP. LIMITED BOOST VENTILATION)

5010 M-WRG-S basic unit Standard unit, air throughput in three stages (15/30/60 m3/h,can be adjusted by the manufacturer upon request to 100 m3/hchangeable) via a switch directly on the unit, temporally limited boostventilation can be activated through a click switch (15 min., 100 m3/h).

5010-5 M-WRG-S/BM basic unit such as standard unit, with an additional 230V signal input forconnecting an external switch or motion sensor

5040-10

M-WRG-BM/AP Motion sensor with timer  (surface-mounted), white

5040-11

M-WRG-BM/UP Motion sensor with timer  (flush-mounted), white

5040-12

M-WRG-BM/ceiling Motion sensor with timer  (ceiling), white

5016-1-0 M-WRG-S/Z-S basic unit Standard unit, with 5V control lines, for connecting to a

3-stage rotary switch on-site

CONTROL VARIATION PUSH-BUTTON SENSOR INCONTROL

5016-1-1 M-WRG-S/Z-T/ basic unit such as standard unit, with 24 V control lines for connecting to a six-fold push-button sensor

5016-1-1-1 M-WRG-S/Z-T-F/ basic unit such as 5016-1-1, with humidity control

5016-1-1-2 M-WRG-S/Z-T-FC basic unit such as 5016-1-1, with humidity and CO2 control

5047-00

M-WRG-T/WS six-fold push-button sensor, with LED display of the currently selectedventilation programme, white

5047-10

M-WRG-T/ES such as 5047-00, stainless steel

5047-20

M-WRG-T/AL such as 5047-00, brushed aluminium

CO2

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 17/28

VENTILATION AND HEAT RECOVERY

  17

Article Diagram Type Description

OPERATIONAL VARIATION FUNCTION CONTROLLER HBE

5016-2-0

M-WRG-S/Z-A basic unit such as standard unit, with a control input for connectingthe function controller M-WRG-HBE

function controller  for the simultaneous operation of up to five ventilation units (type M-WRG-S/Z-A), with programme selector switchfor five ventilation levels and two supply air and exhaust air levels, separate button for temporally limited boost ventilation, multi-colouredLED for functional display, surface-mounted installation.

5041-0M-WRG-HBE Function controller : Control unit for wall installation

5041-1

M-WRG-HBE/F such as 5041-0, with humidity control (including humidity sensor),

values for relative atmospheric humidity can be adjusted via therotary switch

5041-2

M-WRG-HBE/FC such as 5041-0, with humidity and CO2 control(including humidity sensor and mixed gas (CO2) sensor),values for relative atmospheric humidity and CO2 concentrationcan be adjusted via rotary switch

COMFORT UNITSVentilation units with heat recovery, air throughput can be adjusted in ten stages ( 15 -100 m3/h). White,

impact resistant ABS plastic housing, aluminium cross-current plate heat exchanger, electronic control, humidity sensor, 2 air filter G4, antifreezeprotection, acoustic and optical filter replacement notification, fully-automatic air flap control.

All units are certified (TÜV) and approved by the building authority. (Z-5 1.3-138)

COMFORT CONTROL VARIATIONS REMOTE CONTROL

5030 M-WRG-K/basic unit Comfort unit with alphanumeric LCD display and IR remote control  for inputting various programme functions(ventilation levels / Interval operation / day and weekend timeprogramme / humidity control / temperature restriction).Remote control necessary!

5030-2 M-WRG-K/FC basic unit such as comfort unit 5030, with additional mixed gas and CO2 controlRemote control necessary!

5480M-WRG-FB Remote control for M-WRG-K and M-WRG-K/FC

COMFORT UNIT CONTROL VARIATION KEYBOARD

5031-1 M-WRG-K/ZNH-F basic unit Comfort unit with electric heating element for warming supply air andtemperature control, with graphical LCD display and keyboard forinputting various programme functions (ventilation levels/ supply and exhaust air operation / humidity control).

5031-2 M-WRG-K/ZNH-FC basic unit Such as comfort unit 5031-1,with additional mixed gas and CO2 control

5032-1 M-WRG-K/LCD-F basic unit Comfort unit graphical LCD display and keyboard for inputtingvarious programme functions (ventilation levels / supply and exhaustair operation / humidity control)

5032-2 M-WRG-K/LCD-FC basic unit Such as comfort unit 5032-1,with additional mixed-gas and CO2 adjustment.

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 18/28

18 VENTILATION THE RIGHT WAY

Article Diagram Type Description

UNITS BUILDING CONTROL SYSTEM

5016-2-2 M-WRG-S/Z-EIB basic unit Standard unit, EIBfor connecting to an EIB/KNX actuator 

5016-2-1 M-WRG-S/Z-24 basic unit Standard unit, with 24V control linescentral control, e.g. via programmable controls

OPERATING VARIATION EIB/KNX

5016-1-2 M-WRG-S/Z-KNX/ basic unit Standard unit with EIB/KNX actuator for connecting to an EIB bus

5016-1-2-1 M-WRG-S/Z-KNX-F basic unit such as 5016-1-2, with humidity control

5016-1-2-2 M-WRG-S/Z-KNX-FC basic unit such as 5016-1-2, with humidity and CO2 control

OPERATING VARIATION NETWORK (RS 485)

5013 M-WRG-S 485/basic unit Standard unit RS 485 network version, with an integratedmicroprocessor-controlled module for connecting to anRS 485 network for central control

5014-1 M-WRG-S 485-TF/ basic unit such as 5013, with sensors for temperature and humidity(can be configured through the central control)

5014-2 M-WRG-S 485-TFC/ basic unit such as 5013, with sensors for temperature,humidity and mixed gas (CO2)

5040-03M-WRG-SUM 3 Converter from RS485 to USB

5044-0

M-WRG-TCPC Touch screen PC with operating system

5044-1M-WRG-TCSL Software basic licence Meltem Touch Control

5044-2

M-WRG-TCPROG Adaption of software and user interface of 5044-1

5044-3

M-WRG-TCINST software installation and initial operation of the RS-485 network

   R   S  -  4   8  5  n  e   t  w  o  r   k

M-WRG Product Line

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 19/28

VENTILATION AND HEAT RECOVERY

  19

Article Diagram Type Description

ACCESSORIES

5364   M-WRG-BR frame, external dimensions 459 x 438 mm

5045-2  M-WRG-ABK-45 Exhaust manifold 45°, for the supply air range,e.g. with unit installation under the window sill

5046-00 M-WRG-S/PARM Option: Parameterisation Special air throughput

5046-10 M-WRG-S/NOF Option: Power switch without functionality

5046-20 M-WRG-S/ALG Option Preparation Standard unitfor connecting reading device hours of operation

5042-0 M-WRG-ALG reading device hours of operation

5370-1 M-WRG-DB/1 DESIGNframe, frame, option for M-WRG-S units

5370-2 M-WRG-DB/2 such as 5370-1, retrofit kit for M-WRG-S units

5370-5-00

M-WRG-DB/5-KW DESIGNlight, LED lights, option for M-WRG-S units, cold white,only when simultaneously ordering an M-WRG-S unit!

5370-5-10 M-WRG-DB/5-WW such as 5370-5-00, warm white

FILTER (two filters per unit necessary)

5571 M-WRG-FS Standard replacement filter  (for supply and exhaust air) Round filter cartridgefilter class G4, effective filter area 0.36 m2, filter medium special paper, effectivelyblocks dust and pollen.2 filters per unit are necessary for supply and exhaust air.

5572 M-WRG-FA Allergy filter  (only for supply air)Round filter cartridge filter class F7, effective filter area 0.32 m2, particle filter-medium two-layer micro-fibre fleece, in addition to heavy dust, also blocks finedust (to 0.4 um of the size of the particle) and most of the bacteria.Only required for the supply air; the standard replacement filter is sufficient for theexhaust air.

5573 M-WRG-FK Activated carbon filter  (only for supply air)Round filter cartridges filter class M6, effective filter area 0.12 m2, combinationfilter comprised of a two-layered particle filter medium Micro-fibre fleece andseveral activated carbon layers, effectively blocks heavy dust and binds odours andharmful gasses in the activated carbon layer (fuels, nitrogen oxide, ozone, etc.).

Only required for the supply air; the standard replacement filter is sufficient for theexhaust air.

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 20/28

20 VENTILATION THE RIGHT WAY

Article Diagram Type Description

INSTALLATION ACCESSORIES

SURFACE-MOUNTED5062 M-WRG-M/MP Surface-mounting installation kit comprised of drilling templates

for unit and façade finish stainless steel pod, including 2 pieces ofDN 100 supply / exhaust air pipes, length 0.5 m

 FLUSH-MOUNTED5050 M-WRG-M Flush-mounting installation kit (beam construction): wall box with

protective covering, without plastering frame, for installation in timberframe structures.EPS material (polystyrene), virtually flame retardant according toDIN 4102, height Insulation, high level of noise protection, for wallthickness of at least 17.5 cm

5051 M-WRG-M/MB Flush-mounting installation kit (solid construction): such as M-WRG-M,additionally with plastering frame for installing in solid exteriorwalls (brick)

5575-5 M-WRG-M/Fü Installation kit filling piece for M-WRG-M or M-WRG-M/MB to fill in the wall box.Saves time and money.

5045-5  Additional charge: M-WRG-M or M/MB cancelled

5060 M-WRG-PG Plaster fabric

5574 M-WRG-LR 50 Supply and exhaust air pipe (set) 2 x 0.5 m DN 100

5580 M-WRG-LR 100 Supply and exhaust air pipe 1 unit of DN 100, length 1 m

M-WRG Product Line

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 21/28

VENTILATION AND HEAT RECOVERY

  21

Article Diagram Type Description

FAÇADE FINISHES5150 M-WRG-ES Stainless steel pod façade finish

For covering the supply and exhaust air pipes on the exterior façade,resistant to weather and heavy downpours, including fastening mate-rial.Material: V2A (1.4301)Dimensions: 367 x 170 x 60 mmOnly one façade finish is necessary per M-WRG unit.

5150-1 M-WRG-ES/SD such as 5150, with increased noise protection

5153 M-WRG-ES-P such as 5150, white*

5153-1 M-WRG-ES-P/SD such as 5153, with increased noise protection

5152 M-WRG-ESR Façade finish stainless steel (set)For covering the supply and exhaust air pipes on the exterior façade,resistant to weather and heavy downpours through integrated louvre-louver shutters, including fastening material.Material: V2A (1.4301),Dimensions: Outer diameter 106 mm,Façade protrusion 90 mm (visible)Only one set is necessary per M-WRG unit.

5154 M-WRG-ESR-P such as M-WRG-ESR, white*

5155 M-WRG-ESR-RO Façade finish stainless steel pipe with rosettes (set)Design such as art. no. 5152 M-WRG-ESR, however, withadditional rosettes, (outer diameter 168 mm)for subsequent installation.Only one set is necessary per M-WRG unit.

5156 M-WRG-ESR-RO-P such as M-WRG-ESR-RO, white*

5161 M-WRG-ESG/UP Façade finish stainless steel louver design for surface or flush-mountingFor covering the supply and exhaust air pipes on the exterior façade,with perforated sheet metal for installation (for flush-mounting),resistant to weather and heavy downpours, including fasteningmaterial.Material: V2A (1.4301)Dimensions: 376 x 140 x 44 mmOne façade finish is necessary per unit.

5162 M-WRG-ESG/UP-P such as M-WRG-ESG/UP, white*

5163 M-WRG-ESG/AP such as 5161, although design for surface-mounting

5164 M-WRG-ESG/AP-P such as 5163, white*

Flush-mounted

Surface-mounted

* coated with powder – white RAL 9016

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 22/28

22 VENTILATION THE RIGHT WAY

Article Diagram Type Description

ACCESSORIES INSTALLATION VARIATION “WINDOW EMBRASURE”5157 M-WRG-EFL/UP  Façade finish stainless steel window embrasure flush-mounted,

with perforated sheet metal for installation (flush-mounted), resistant toweather and heavy downpours, including fastening material.

Material: V2A (1.4301)Dimensions: 361 x 92.5 x 29 mm (flush with embrasure)Only one façade finish is necessary per M-WRG unit.

5158   M-WRG-EFL/UP-P such as M-WRG-EFL/UP, white*

5159   M-WRG-EFL/AP such as 5157, although design for surface-mounting

5160   M-WRG-EFL/AP-P such as 5159, white*

5512-00 M-WRG-EFL/MHK Installation assistance window embrasure, brief 

5512-01   M-WRG-EFL/MHL Installation assistance window embrasure, detailed

5574   M-WRG-LR 50 Supply and exhaust air pipe (set) 2 x 0.5 m DN 100

5590 M-WRG-FK-F Flat duct 110 x 53 mm, length 1 m

5599 M-WRG-BB Butyl tape: B-50 mm; L-20m/ roll(one roll is sufficient for 10 M-WRG units)

5579-10

M-WRG-RR-FK

DN 100 transition section on flat ductwork 110 x 53 mm

 * coated with powder – white RAL 9016

M-WRG Product Line

UP

AP

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 23/28

VENTILATION AND HEAT RECOVERY

  23

Article Diagram Type Description

ACCESSORIES INSTALLATION VARIATION “TWO-ROOM VENTILATION FLEXIBLE PIPE CONNECTION”

5050-21 M-WRG-M/FR1 Installation kit flush-mounting such as 5050, timber frame structure with a DN 75flexible pipe connection

5050-22 M-WRG-M/FR2 Installation kit flush-mounting such as 5050, timber frame structure with two DN 75flexible pipe connections

5051-21 M-WRG-M/MB-FR1 Installation kit flush-mounting such as 5051, solid construction with a DN 75flexible pipe connection

5051-22 M-WRG-M/MB-FR2 Installation kit flush-mounting such as 5051, solid construction with two DN 75flexible pipe connections

ACCESSORIES INSTALLATION VARIATION “TWO-ROOM VENTILATION FLAT DUCTWORK CONNECTION”

5050-11 M-WRG-M/FK1 Installation kit flush-mounting such as 5050, timber frame structure with a 110 x 53 mmflat ductwork connection

5050-12 M-WRG-M/FK2 Installation kit flush-mounting such as 5050, timber frame structure with two 110 x 53 mmflat ductwork connections

5051-11 M-WRG-M/MB-FK1 Installation kit flush-mountingsuch as 5051, solid construction with a 110 x 53 mmflat ductwork connection

5051-12 M-WRG-M/MB-FK2 Installation kit flush-mounting such as 5051, solid construction with two 110 x 53 mmflat ductwork connections

ACCESSORIES “TWO-ROOM VENTILATION”5373 M-WRG-VS 110-IB Inside frame for connecting a second room

5365 M-WRG-KA/UP Ductwork adapter for flush-mounted unitsConnector piece for flat ductwork

   B  e  a  m

   S  o   l   i   d  c  o  n  s   t  r  u  c   t   i  o  n

   S  o   l   i   d  c  o  n  s   t  r  u  c   t   i  o  n

   B  e  a  m

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 24/28

24 VENTILATION THE RIGHT WAY

Article Diagram Type Description

ACCESSORIES PIPE AND FLAT DUCTWORK5579-10 M-WRG-RR-U Transition section DN 100 on flat ductwork,

Arch 90°

5581 M-WRG-RR-V DN 100 connector  

5582 M-WRG-RR-B DN 100 arch 90°

5583 M-WRG-RR-RH Pipe brace 2 DN 100 units

5590 M-WRG-FK-F Flat duct 110 x 53 mm, length 1 m

5591 M-WRG-FK-V Connector for flat ductwork

5592

M-WRG-FK-B Arch 90° horizontal

5593 M-WRG-FK-W Angle 90° vertical

5594 M-WRG-FK-Ü Transition section DN 100 on flat ductwork, straight

5595 M-WRG-FK-FH Flat ductwork brace

5374 M-WRG-KA-V2 Ductwork adapter for flush-mounted and surface-mounted unitswhen flush-mounting the flat ductwork

5599 M-WRG-BB Butyl tape: B-50mm; L-20m/ roll(one roll is sufficient for 10 M-WRG units)

M-WRG Product Line

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 25/28

VENTILATION AND HEAT RECOVERY

  25

Functionality

   V  e  n   t   i   l  a   t   i  o  n  s   t  a  g  e  s   I  -   I   I   I

   V  e  n   t   i   l  a   t   i  o  n  s   t  a  g  e  s  1  -  1   0

   S  u  p  p   l  y   /  e  x   h  a  u  s   t  a   i  r  s  u  r  p   l  u  s

   F   i   l   t  e  r  r  e  p   l  a  c  e  m  e  n   t   d   i  s  p   l  a  y

   T   i  m  e  r  p  r  o  g  r  a  m  m  e

   H  u  m   i   d   i   t  y  c  o  n   t  r  o   l

   C   O  2  c  o  n   t  r  o   l

   T  e  m  p  o  r  a   l   l  y   l   i  m   i   t  e   d

   B  o  o  s   t  v  e  n   t   i   l  a   t   i  o  n

   N  o  m   i  n  a   l  v  e  n   t   i   l  a   t   i  o  n

   S  u  p  p   l  y  a   i  r  w  a  r  m   i  n  g

   S   t  a   t  u  s  r  e  q  u  e  s   t

Comfort unit with alphanumeric display,IR remote control and humidity sensor 

  5030 M-WRG-K X X X X X X X

Comfort unit with humidity and CO2 sensor    5030-2 M-WRG-K/FC X X X X X X X X

Comfort unit with graphical displayand humidity sensor 

  5032-1 M-WRG-K/LCD-F X X X X X X

Comfort unit with graphical display,humidity and mixed gas (CO2) sensor 

  5032-2 M-WRG-K/LCD-FC X X X X X X X

Comfort unit with graphical display,supply air warming and humidity sensor 

  5031-1 M-WRG-K/ZNH-F X X X X X X X

Comfort unit with graph. Display, supply airwarming and CO2 sensor 

  5031-2 M-WRG-K/ZNH-FC X X X X X X X X

Standard unit   5010 M-WRG-S X X X X

Standard unit for connectingto a 3-stage rotary

  5016-1-0 M-WRG-S/Z-S X X X X

Standard unit for connectingto a six-fold push-button with LED display

  5016-1-1 M-WRG-S/Z-T X X X opt. opt. X X

Standard unit with 230V signal input 5010-5 M-WRG-S/BM X X (1) X

Standard unit for connectingto function controller M-WRG-HBE

  5016-2-0 M-WRG-S/Z-A (2) X X ext. X X X X

Standard unit with EIB/KNX actuator for connecting to an EIB bus

  5016-1-2 M-WRG-S/Z-KNX X X X X X X

Standard unit with EIB/KNX actuator for connectingto an EIB bus with humidity sensor 

  5016-1-2-1 M-WRG-S/Z-KNX-F X X X X X X X

Standard unit with EIB/KNX actuator for connecting

to an EIB bus with humidity and CO2 sensor   5016-1-2-2

M-WRG-S/Z-KNX-FC X X X X X X X XStandard unit for connectingto RS485 network

5013 M-WRG-S 485  X X X X X X X

Standard unit for connecting to RS485 network with temp. and humidity sensor 

  5014-1 M-WRG-S 485-TF X X X X X X X X

 Standard unit for connecting to RS485 network with temp., humidity and CO2 sensor 

  5014-2 M-WRG-S 485-TFC X X X X X X X X X

Adjustableunit functionality

Dimensions(1) e.g. when connecting to motion sensor with adjustable subsequent runtime(2) Ventilation levels 1-5 

Art. no. Unit type(Basic unit)

Dimension 365 mm variable,according to the wall structure;

can be cut to length; min.175

 mm thick, max. variable (wallstructures that are greater than365 mm will be compensatedthrough longer ventilation pipesart. 5580)

Unit dimensions Installation kit for flush-mounting M-WRG-M/MB (wall box)

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 26/28

26 VENTILATION THE RIGHT WAY

Technical Specifications

* Values can be verified with testing certifi-cates.

** other air output levels can be set bythe manufacturer up to 100 m3/h

*** at 30 m3/h

Unit type M-WRG-S M-WRG-K M-WRG-K-LCD

Air output (m3/h)* 15/30/60** 15 to 100 15 to 100 

Output controller* 3-stage 10-stage 10-stageHeat exchanger Cross-current plate heat exchanger

Heat provisioning (%)* 76 

Leakage (%)* 0.1 

Motor / supply air / exhaust air ventilator EC DC Radial

Power consumption (W)* 3.8 / 5.2 / 12.5 3.8 to 34 3.8 to 34

Electrical

power consumption related to the airflow throughput (W/m3/h) *,*** 0.17

Max. power consumption (A) * 0.06 0.16 0.16

Power supply cord (mm2)  2 x 1.5 

Operating voltage (V / Hz) 230 / 50 

Sound pressure level flush-mounted (SL in dB (A) 10 m2)* 15.5 / 24 / 36 15.5 to 46.5 15.5 to 46.5

 Sound pressure level surface-mounted (SL in dB (A) 10 m2)* 19 / 24 / 35 19 to 46 19 to 46

Element-standard noise level difference flush-mounted/surface-mounted

(D n,e,w in dB) with unit turned off * 56 / 53 

Element-standard noise level difference flush-mounted/surface-mounted

(D n,e,w in dB) with unit turned on* 50 / 50 

Weight (kg) approx. 8.1 

Outside air / exhaust air connection (DN) 100 

Unit dimensions (HxWxT) in mm 409 x 388 x 196

Visible depth of unit with surface-mounting in mm 196

Visible depth of unit with flush-mounting in mm 66

Filter class / filter area in m2

  Standard filter G4 / 0.36 

Allergy filter (optional) F7 / 0.32 

Activated carbon filter (optional) M6 / 0.12 

Filter replacement notice (depending on the degree of contamination of the filter) acoustic optical/ acoustic optical / acoustic

Condensation draining via exhaust air pipe

Fully automatic air flap control

(with On/Off, standby operation and loss of power) yes

Antifreeze protection yes

Humidity control no yes yes

Mixed gas (CO2) control no optional optional

Diverse ventilation programmes (time/temp./supply & exhaust air, ...)no yes yes

Supply air after warming no no optional

Infrared remote control no yes no

LCD display no yes yes

Certified (TÜV) yes

General approval by the building authority (DIBt) Z-51.3-138 

Protection class standard / with protective cap IP X1 / IP X4

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 27/28

  27

VENTILATION AND HEAT RECOVERY

Room for your notes

8/10/2019 d Meltem Mwrg Broschuere Print 2013

http://slidepdf.com/reader/full/d-meltem-mwrg-broschuere-print-2013 28/28

 Meltem

Wärmerückgewinnung GmbH & Co. KGAm Hartholz 4 · D-82239 AllingTelephone: +49 (0) 8141 / 40 41 79 - 0

VENTILATION AND HEAT RECOVERY

Distribution partners:

Clean air.GREENTECHNOLOGY.

SINGLE-FAMILY HOME 

Clean air for the entire family

SCHOOL AND KINDERGARTEN

Sufficient oxygen without outside noise

HEALTHY LIVING

Fresh air, less pollutants

RESIDENTIAL COMPLEX 

Protection against mould and moisture damage

Meltem is a leading manufacturer of decentralised

ventilation systems in Europe. With innovative solutions,

Meltem provides for fresh and clean air so that you

can feel well all-round at home or in your professional

environment.

   5   3   1   6  -   0   0

   K   W    1

   0   /   2   0   1   3