convenience store lighting products
DESCRIPTION
ÂTRANSCRIPT
www.atgelectronics.com Toll free: 877-461-5333 E-mail: [email protected]
Product Description
eLucent™ WP Series LED Wall pack is designed for applications that require
lighting with a long life and low maintenance requirement.
With effective thermal management, corrosion-resistant, and die-cast
aluminum enclosure with an architectural dark brown finish, eLucent™ WP
Series LED Wall provides glare free, uniform illumination while providing a
safe and comfortable visual experience.
eLucent™ WP Series LED Wall pack adopts high luminous efficacy SMD
LEDs. They are available in 40 watts, 60 watts and 90watts.
With superior 60%-90% energy savings, compared to halogen lamp or a metal
halide lamp, eLucent™ WP90 achieves a superlative luminous flux of 8500 lm
and only consumes approximate 90 watts.
High lumen output, energy-efficient optical control and easy universal
installation features confirm the eLucent™ WP Series LED Wall as the
absolute choice for indoor and outdoor illumination.
eLucent™
WP Series LED Wall Pack
Performance Summary
Power consumption 40W 60W 90W
Lumens 4000 lm 6000 lm 8500 lm
PF/THD >0.9/<15% >0.9/<20% >0.9/<20%
CCT: 5700 K
Color Accuracy: CRI 85, R9>20
L70 lifetime: 130,000h
W WWP
W
WPFC40
W
WPFC60 & WPFC90
W
WP0040
W
WP0060 & WP0090
Family Model
WPFC40 WP0040
WPFC60 WP0060
WPFC90 WP0090
WPFC Series WP00 Series WPDS SeriesDark Sky Compliant Dark Sky Compliant
www.atgelectronics.com Toll free: 877-461-5333 E-mail: [email protected]
Ordering Information
Typical Order Example: WPFC60HU570000
Product Specifications
CONSTRUCTION & MATERIALS
Type WPFC40 WPFC60 WPFC90 WP0040 WP0060 WP0090
Dimension 362*293*230 mm
(14.25*11.54*9.06")
465*350*232 mm
(18.31*13.78*9.13")
465*350*232 mm
(18.31*13.78*9.13")
363*230*195 mm
(14.29*9.06*7.68")
465*230*244 mm
(18.31*9.06*9.61")
465*230*244 mm
(18.31*9.06*9.61")
Housing Die-cast aluminum
Lens Type Glass
ENVIRONMENTAL SYSTEM
Work Environment Indoor and outdoor use
Operating Temperature -20℃~60℃(-4~140℉)
OPTICAL SYSTEM
Type WPFC40/WP0040 WPFC60/WP0060 WPFC90/WP0090
Luminous Flux 4000 lm 6000 lm 8500 lm
Luminous Efficacy Typ. 100 lm/W
Color Temperature 5700 K
CRI 85
Lumen maintenance at 6000h 99%
ELECTRICAL SYSTEM
Type WPFC40/WP0040 WPFC60/WP0060 WPFC90/WP0090
Input Voltage 100~277VAC/0.31A 100~277VAC/0.48A 100~277VAC, 0.75A
Off State Power 0W 0W 0W
Power Consumption 40W 60W 90W
THD <15% <20% <20%
Power Factor >0.9
REGULATORY & VOLUNTARY QUALIFICATIONS
ETL & cETL Listed (ETL No.: 4003329)
DLC, LM79
CE, RoHS
SERIES HOUSING WATT VOLTAGE CCT CONTROL OPTIONS
WP=Wall Pack FC=Full Cutoff
40=40W
60=60W
90=90W
HU=100-277V 57=5700K
00=non-dimming 00=Default
eLucent™
WP Series LED Wall Pack
SIDE BOTTOM
BACK TOP
Project
Catalog #
Type
DESCRIPTION
Specifications and dimensions subject to change without notice. DATASHEET 04.23.2014
| | | | |
ORDERING INFORMATIONExample: TL-WMB301-01-BZ
TL WMB301 01
Series Color
TL WMB301 01
EconoPakWall Mount Luminaire
ENERGY DATA
Input Voltage (V AC)
System Level Power (W)
Delivered Lumens (Lm)
System Efficacy (Lm/W)
Correlated Color Temp (K)
Minimum CRI
LED L70 Lifetime (Hrs)*
Operating Temp (ºC)
120 - 277
30
2500
82
5000
70
142,000
-20 to 40
SPECIFICATIONS
Dimensions (in)
Units/carton
Net weight
Environmental Rating
7.75 x 6.625 x 4.25
1
5.4 lbs
Wet
FEATURESPowered by a constant current power supply to achieve maximum efficiency
(see separate data sheet)
IP65 ingress protection
Designed to meet Class 2 safety requirements
5-year warranty
l
l
l
l
EconoPak is a multi-purpose LED luminaire designed for indoor and outdoor area lighting applica-
tions. Delivering maximum lumens for 142,000 hours* while using only 30 Watts of power, its compact
design with enclosed power supply make it ideal for such applications as flood lighting, sign lighting,
landscape and general area lighting. The EconoPak can be mounted to a wall, ceiling or conduit,
making it one of the most versatile LED luminaires in the market.
CERTIFICATION
UL Listed USA+Canada File # E352127
LM-79 Test Report
l
l
† US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are solely meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors.
BZ
WH
Bronze
White
Project
Catalog #
Type
DESCRIPTION
US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors.
Specifications and dimensions subject to change without notice
Canopy LED LuminaireHigh Flux
94 W / 9300 Lumens
ENERGY DATA
347-480
102
9300
91
5000
80 min
173,000
79,000
-40 to 50
The Canopy Star canopy LED luminaire from US LED is a perfect solution for parking structures, shopping area walkways, petrol stations and exterior canopies. The Canopy Star LED canopy is surface mounted for easy adaptation with a typical mounting height of 10 to 25 feet. Designed to illuminate area features with sharp, accurate color to increase security and visibility, the Canopy Star is cost effective to install and will replace conventional fluorescent, HPS and metal halide lighting.
POWER SUPPLY INFORMATION
FEATURES
Remarkable light output using only 94 Watts
Class 2 compliant design (low voltage, limited power)
L70 lifetime of 173,000 hours*
Luminaire is IP66 compliant
Protective coating added to resist corrosion
5-year warranty
l
l
l
l
l
l
SPECIFICATIONS
Dimensions (in)
Units/carton
Net weight
Environmental Rating
18.62 x 18.62 x 2.75
1
9 lbs
Wet
CERTIFICATIONl
l
l
Input Voltage (VAC)
System Level Power (W)
Delivered Lumens (Lm)
System Efficacy (Lm/W)
Color Temperature (K)
Color Rendering Index
L70 Calculated Life (Hrs)*
L85 Calculated Life (Hrs)*
Operating Temp (ºC)
120 - 277
94
9300
99
5000
80 min
173,000
79,000
-40 to 50
SeriesDrive CurrentType
Example: PUC-UNV1-3570
UL 1598 certified by Intertek (ETL 4006735)
DesignLights Consortium qualified
LM-79 available
FIXTURE ORDERING INFORMATIONExample: CNP1-50
CNP1 50
Series
CNP1
Color Temp (K)
50 5000K
PUC UNV1- (120-277 VAC) 3570
**PUC UNV2 - (347/480 VAC) 3570
* US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are solely meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors.
** High voltage fixture not DesignLights Consortium qualified
Project
Catalog #
Type
DESCRIPTION
US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors.
DATASHEET 05.06.2014Specifications and dimensions subject to change without notice
Canopy LED LuminaireUltra Flux
192 W / 18,000 Lumens
ENERGY DATA
347-480
210
18,000
86
5000
70 min
> 200,000
-40 to 45
The Canopy Star canopy LED luminaire from US LED is a perfect solution for parking structures, shopping area walkways, petrol stations and exterior canopies. The Canopy Star LED canopy is surface mounted for easy adaptation with a typical mounting height of 20 to 30 feet. Designed to illuminate area features with sharp, accurate color to increase security and visibility, the Canopy Star is cost effective to install and will replace conventional fluorescent, HPS and metal halide lighting.
POWER SUPPLY INFORMATION
FEATURES
Remarkable light output using only 192 Watts
Class 2 compliant design (low voltage, limited power)
L85 lifetime of >200,000 hours*
Luminaire is IP66 compliant
Protective coating added to resist corrosion
5-year warranty
l
l
l
l
l
l
SPECIFICATIONS
Dimensions (in)
Units/carton
Net weight
Environmental Rating
18.62 x 18.62 x 2.75
1
9 lbs
Wet
CERTIFICATION
Input Voltage (VAC)
System Level Power (W)
Delivered Lumens (Lm)
System Efficacy (Lm/W)
Color Temperature (K)
Color Rendering Index
L85 Calculated Life (Hrs)*
Operating Temp (ºC)
120 - 277
192
18,000
94
5000
70 min
> 200,000
-40 to 45
SeriesDrive CurrentType
Example: PUC-UNV1-7140
FIXTURE ORDERING INFORMATIONExample: CNP2-50
CNP2 50
Series
CNP2
Color Temp (K)
50 5000K
l
l
l
UL 1598 certified by Intertek (ETL 4006735)
DesignLights Consortium qualified (**Low voltage)
LM-79 available
* US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are solely meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors.
** High voltage fixture not DesignLights Consortium qualified
PUC UNV1- (120-277 VAC) 7140
**PUC UNV2 - (347/480 VAC) 7140
www.atgelectronics.com Toll free: 877-461-5333 E-mail: [email protected]
Ordering InformationTypical Order Example: T8ID12HU40F000
Product SpecificationsCONSTRUCTION & MATERIALSDimension 4ft/1.2mHousing Extrusion Aluminum and PC diffuserFinish Color SilverLens Type Clear/Frosted
SERIES GENERATION SIZE VOLTAGE CCT Lens Type OPTIONS
T8=T8 Tube ID=DLC IPS 12=1.2m/4ft HU=100-277VAC 40=4000K50=5000K
F= Frosted LensC= Clear Lens 000=Default
iBright™16W DLC IPS T8 LED Tube
www.atgelectronics.com Toll free: 877-461-5333 E-mail: [email protected]
ENVIRONMENTAL SYSTEMWork Environment Indoor use (applicable for dry environments)Operating Temperature -20~60℃ (-4~140℉)
OPTICAL SYSTEMLuminous Flux 1600 lmLuminous Efficacy 100 lm/WColor Temperature 4000K & 5000KCRI 80Lumen maintenance at 6000h 98.11%
ELECTRICAL SYSTEMInput Voltage/Current 100~277VACOff State Power 0WPower Consumption 16WPower Factor >0.92THD <20%
REGULATORY & VOLUNTARY QUALIFICATIONSDesign Lights ConsortiumETL/cETLCE, RoHS
www.atgelectronics.com Toll free: 877-461-5333 E-mail: [email protected]
Ordering InformationTypical Order Example: T8ID12HU40F023
Product SpecificationsCONSTRUCTION & MATERIALSDimension 4ft/1.2mHousing Extrusion Aluminum and PC diffuserFinish Color SilverLens Type Clear/Frosted
SERIES GENERATION SIZE VOLTAGE CCT Lens Type OPTIONS
T8=T8 Tube ID=DLC IPS 12=1.2m/4ft HU=100-277VAC 40=4000K50=5000K
F= Frosted LensC= Clear Lens 023=23W
iBright™23W DLC IPS T8 LED Tube
www.atgelectronics.com Toll free: 877-461-5333 E-mail: [email protected]
ENVIRONMENTAL SYSTEMWork Environment Indoor use (applicable for dry environments)Operating Temperature -20~60℃ (-4~140℉)
OPTICAL SYSTEMLuminous Flux 2300LMLuminous Efficacy 100 lm/wColor Temperature 4000K & 5000KCRI 80Lumen maintenance at 6000h 98.11%
ELECTRICAL SYSTEMInput Voltage/Current 100~277VACOff State Power 0WPower Consumption 23WPower Factor >0.92THD <20%
REGULATORY & VOLUNTARY QUALIFICATIONSDesign Lights ConsortiumETL/cETLCE, RoHS
Project
Catalog #
Type
Specifications and dimensions subject to change without notice. DATASHEET 05.06.2014
DESCRIPTIONThe QubeLot2 evenly illuminates walkways, streets and parking areas. The classic design of this lumi-
naire seamlessly blends into all forms of architecture. Highly efficient and long-lasting, the QubeLot2
is an ideal replacement for HID. Exceptional high-brightness LEDs result in higher light levels and
significant energy savings. High-efficiency 5200K LEDs mounted to a metal-core circuit board and
aluminum heat sink, ensure optimal thermal management and long life (L85 124,000 hrs).
FEATURES AND SPECIFICATIONSType 5 medium light distribution and Type 2 medium distribution pattern available
Comes fully equipped with power supply
Bi-level light option available for dimmed-down lower power operation
EPA rating of fixture is 0.7/sq ft and mount is 0.13/sq ft
5-year warranty
ENERGY DATAInput Voltage (V AC)
System Level Power (W)
Delivered Lumens (Lm)
System Efficacy (Lm/W)
Correlated Color Temp (K)
L70 Calculated Life (hrs)*
L85 Calculated Life (hrs)*
Minimum CRI
Operating Temperature (°C)
120 - 480
136
12,300
90
5200K
289,000
124,000
65
-40 to 45
Parking Lot Luminaire4-Qube
QubeLot2
SPECIFICATIONSDimensions (in)
Units/carton
Net Weight
Environmental Rating
25.2 x 12.7 x 3.3
1
16 lbs
Wet
ORDERING INFORMATION
QL2 1 52
Series Light DistPattern
# ofQubes
Color Temp
QL2 1 52 5200K
Example: QL2-1-UNVL-4-5M-52-0
Input Voltage
5M 5 Medium
2M* 2 Medium
UNVL 120-277
UNVH* 277-480
Options
0 0-10V Dimming
1 Photocell Socket
2 **DynaDimmer
3 **Photocell Socket & DynaDimmer
Variant
3
4
* Not DesignLights Conortium qualified** Note: Options 2 and 3 not available with UNVH Input Voltage
ENERGY DATAInput Voltage (V AC)
System Level Power (W)
Delivered Lumens (Lm)
System Efficacy (Lm/W)
Correlated Color Temp (K)
L70 Calculated Life (hrs)*
L85 Calculated Life (hrs)*
Minimum CRI
Operating Temperature (°C)
120 - 480
104
9300
89
5200K
289,000
124,000
65
-40 to 45
SPECIFICATIONSDimensions (in)
Units/carton
Net Weight
Environmental Rating
25.2 x 12.7 x 3.3
1
14.5 lbs
Wet
l
l
l
l
l
3-QUBE 4-QUBE
CERTIFICATIONUL Listed USA and Canada File# E338791
DesignLights Consortium qualified
l
l
* US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are solely meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors.
* US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are solely meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors.
Horizontal mounting only
Project
Catalog #
Type
Specifications and dimensions subject to change without notice. DATASHEET 04.04.2014
6-Qube Area Light Fixture
ORDERING INFORMATION
QD1 50 6
Series Color Light DistPattern
# of QubesColorTemp
QD1 50 5000K
Example: QD1-1-UNVL-5M-50-6-0
DESCRIPTIONThe Dorado 6-Qube is an LED luminaire designed to be mounted vertically or horizontally in outdoor
applications. High-performance LEDs provide light where you need it, at a fraction of the operating
cost of HID technologies. With a lifetime of more than 200,000 hours*, the Dorado is the ideal
replacement for 1000W metal halide fixtures. Slip-fitter, Pole Mount or Trunnion Mount options are
available for easy and fast installation.
FEATURESSlip-fitter, Pole Mount and Trunnion Mount options available
Three light distribution patterns: Type 5M, Type 3M, and 120° angle
5-year warranty
l
l
l
Dorado
CERTIFICATIONUL approved (#E338791)
LM-80 pending
LM-79 pending
l
l
l
ENERGY DATAInput Voltage (VAC)
System Level Power (W)**
Delivered Lumens (Lm)
System Efficacy (Lm/W)**
Correlated Color Temp (K)
L70 Calculated Life (hrs)*
L85 Calculated Life (hrs)*
Minimum CRI
Operating Temperature (°C)
SPECIFICATIONSDimensions
Units/carton
Net Weight
Environmental Rating
23.3” x 21.0” x 7.1”
1
26 lbs
Wet
** Measured at 277 VAC
120-277/347-480
288
30,800
107
5000K
>200,000
182,000
70
-40 to 40
UNVL 120-277
UNVH 347-480
6 6-Qubes
† Special order, not stocked
1 Bronze
2 White †
3 Black †
5M
3M
12
Options
0 None
1 Photocell Socket
Voltage
* US LED product ‘Lifetimes’ refer only to the LED light engine, not the power source, and are based on the Illuminating Engineering Society’s TM21 methodology based on 25°C/77°F ambient temperature. The lifetimes are solely meant to be a guide for expected LED degradation and not a warranty or predictive of their actual life, which can be affected by ambient temperatures and other factors.
ILTCaseLightLED Refrigerated Case Lighting System
International Light Technologies, Peabody, MA (USA) • 45 Years of Lighting Experience – We Know Light!
CaseLight is DLC Listed!
Make Your Prepared Foods POPWith CaseLight™ LED Modules!
• Easily Replace Existing Cooler/Freezer Display Case Fluorescent Lights
• Easy Mounting Using TEK Screws or VHB Foam Tape When Space is Limited• No Need to Empty Shelves!
• Lower Energy Bills and No Burned Out Bulbs!• Long Fixture Life - YEARS vs. Weeks/Months• Low Maintenance-5 Year Warranty on CaseLight
Modules & Power Supplies• DLC Listed - Eligible for ALL Rebates• CaseLight Modules Made in the USA
Improving on the success of ILT’s previous CaseLight modules for refrigerated/freezer display cases, ILT’s new, more efficient CaseLight module has even lower power consumption and higher overall optical performance for your reach-in coolers and freezers. For Retrofit or New cases, ILT CaseLight can be installed easily and cost-effectively.
LED-based CaseLight modules provide all of the ad-vantages of LED-based lighting including much longer life (greater than 50,000 hours), much lower energy consumption and much better lighting characteristics - brighter light focused on the merchandise. Plus all of ILT’s CaseLight modules are DLC listed qualifying for maximum utility rebates
45-Plus Years of ILT Lighting ExperienceGoes Into Every CaseLight
ILTINNOVATIONS
Part Number Description Color Temp. (K) Lumens Energy (Watts) Life (Hours) CRI (Typical)
ILT48-BAO-W50CE CaseLight, 48”, Brite Anodize, Center unit 5000 1200 15 50000 85
ILT48-BAO-W50LE CaseLight, 48”, Brite Anodize, Left unit 5000 600 7.5 50000 85
ILT48-BAO-W50RE CaseLight, 48”, Brite Anodize, Right unit 5000 600 7.5 50000 85
ILT48-BAO-W40CE CaseLight, 48”, Brite Anodize, Center unit 4000 1160 15 50000 85
ILT48-BAO-W40LE CaseLight, 48”, Brite Anodize, Left unit 4000 580 7.5 50000 85
ILT48-BAO-W40RE CaseLight, 48”, Brite Anodize, Right unit 4000 580 7.5 50000 85
ILT48-BAO-W35CE CaseLight, 48”, Brite Anodize, Center unit 3500 1160 15 50000 85
ILT48-BAO-W35LE CaseLight, 48”, Brite Anodize, Left unit 3500 580 7.5 50000 85
ILT48-BAO-W35RE CaseLight, 48”, Brite Anodize, Right unit 3500 580 7.5 50000 85
ILT60-BAO-W50CE CaseLight, 60”, Brite Anodize, Center unit 5000 1600 20 50000 85
ILT60-BAO-W50LE CaseLight, 60”, Brite Anodize, Left unit 5000 800 10 50000 85
ILT60-BAO-W50RE CaseLight, 60”, Brite Anodize, Right unit 5000 800 10 50000 85
ILT60-BAO-W40CE CaseLight, 60”, Brite Anodize, Center unit 4000 1547 20 50000 85
ILT60-BAO-W40LE CaseLight, 60”, Brite Anodize, Left unit 4000 773 10 50000 85
ILT60-BAO-W40RE CaseLight, 60”, Brite Anodize, Right unit 4000 773 10 50000 85
ILT60-BAO-W35CE CaseLight, 60”, Brite Anodize, Center unit 3500 1547 20 50000 85
ILT60-BAO-W35LE CaseLight, 60”, Brite Anodize, Left unit 3500 773 10 50000 85
ILT60-BAO-W35RE CaseLight, 60”, Brite Anodize, Right unit 3500 773 10 50000 85
ILT70-BAO-W50CE CaseLight, 70”, Brite Anodize, Center unit 5000 2000 25 50000 85
ILT70-BAO-W50LE CaseLight, 70”, Brite Anodize, Left unit 5000 1000 12.5 50000 85
ILT70-BAO-W50RE CaseLight, 70”, Brite Anodize, Right unit 5000 1000 12.5 50000 85
ILT70-BAO-W40CE CaseLight, 70”, Brite Anodize, Center unit 4000 1940 25 50000 85
ILT70-BAO-W40LE CaseLight, 70”, Brite Anodize, Left unit 4000 970 12.5 50000 85
ILT70-BAO-W40RE CaseLight, 70”, Brite Anodize, Right unit 4000 970 12.5 50000 85
ILT70-BAO-W35CE CaseLight, 70”, Brite Anodize, Center unit 3500 1940 25 50000 85
ILT70-BAO-W35LE CaseLight, 70”, Brite Anodize, Left unit 3500 970 12.5 50000 85
ILT70-BAO-W35RE CaseLight, 70”, Brite Anodize, Right unit 3500 970 12.5 50000 85
I n t e r n a t i o n a l L i g h t T e c h n o l o g i e s
Power Supplies
ILT-LPF-40-2440 Watt, UL Class 2, 100-277VAC input, 24VDC output
ILT-CEN-60-2460 Watt, UL Class 2, 100-277VAC input, 24VDC output
ILT-D24V100UNVA100W, UL Class 2, 120-277VAC input, 24VDC output
10 Technology Drive, Peabody, MA 01960978-818-6180 978-818-6181 fax
www.intl-lighttech.com
Installation Instructions
Note – Wiring and mounting instructions are applicable for both center and end units
Model Numbers – Example ILT60-BAO-W50CEILTAA-
(AA=Length-inches)BAO-
(Brite Anodize finish)
WBB(BB=color temp)
CE(C=Configuration; E=External Power
Supply)ILT48 (48”) “ 35 (3500K) CE (Center, External Power Supply)ILT60 (60”) “ 40 (4000K) LE (Left, External Power Supply)ILT70 (70”) “ 50 (5000K) RE (Right, External Power Supply)
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
B. Before installing, servicing or cleaning unit, switch power off at the service panel and follow appropriate lock out / tag out safety procedures.
FOR YOUR SAFETY:Read and observe all CAUTIONS and WARNINGS shown throughout these instructions. While performing installations described, gloves, safety glasses or goggles should be worn.
PREPARE ELECTRICAL WIRING:A. Electrical Requirements – This fixture must be powered by a Meanwell, 60W, 24VDC power
supply, model CEN-60-24, ILT part number ILT-CEN-60-24, connected to a properly grounded branch circuit, protected by a circuit breaker.
B. Grounding Instructions – This power supply must be connected to a grounded metal, permanent wiring system.
C. Strain Relief Requirements – This fixture is equipped with a cord but no attachment plug. Therefore, the installer must include a strain relief sized properly for the cable and opening in the junction box it is attaching to. An example is the Heyco Products strain relief, part number 1150, or equivalent if routing wire into a junction box or through an access hole.
CI-101 Rev. A Page 1 4/25/2012
International Light Technolgies 978-818-6180 Brite Energy Solutions 308-367-4542
TOOLS NEEDED:- Wire connectors- Wire cutters- Gloves- Tape measure- Wire stripper- Safety glasses- Center punch- Power drill- Screwdriver- #6 x 1 1/2” self-tapping screws
Prepare for Mounting Light Fixture to Mullion – using #6 x 1 1/2” self-tapping screws
CAUTION – Turn off power to the mullion lighting system before removing any covers.- Measure the total length of the mullion to determine which model/length unit to install. Center
the fixture vertically on the mullion. Mark the top and bottom of the fixture.- Measure the total width of the mullion and mark a vertical line, ½ the total width near the top,
6” from the top, 6” from the bottom.- Mark a horizontal line 6” down from the top of the fixture. Mark a horizontal line 6” from the
bottom of the fixture.
CAUTION – Prior to installing screws, make sure that there are no existing components inside the mullion in the areas to be drilled. Do not drill through “DO NOT DRILL” label.
- Use power drill and screw bit and install 4, #6 x 1 1/2” self-tapping screws through the center indent of the fixture. Install 2-3 screws, one 6” from top, one 6” from bottom and one in the center if necessary.
NOTE – Starting the screws into the fixture with the fixture outside the cooler may make it easier for installation. Screws can then be fully inserted into mullion while holding fixture in place.
Alternate Mounting MethodHigh quality VHB-type foam tape may also be used to mount the fixtures.
− Thoroughly clean the back of the fixture and the mullion surface.− Using 1/2”-3/4” wide VHB tape, apply tap to back surface of fixture to within 3” of top and
bottom of fixture.
CI-101 Rev. A Page 2 4/25/2012
10 Technology Dr., Peabody, MA 01960 978-818-6180 978-818-6181 fax
− Dry fit fixture to mullion. Once fit is confirmed, peel release paper, align fixture and press against mullion for entire length of fixture.
Connect Wiring from FixtureCAUTION – Ensure that all connection points are sealed for damp location using the appropriate method per the NEC or local electrical code.
- Cut the fixture cable to the appropriate length to terminate to DC power at the Power Supply.- Where necessary, insert the proper strain relief on the cable and secure to hole in mullion or
junction box.- Strip the cable jacket and then strip the individual two wires. Attach the Black wire to the
Black wire of the power supply using twist-on wire connector. Attach the Red wire to the Red wire of the power supply using twist-on wire connector.
Connect Wiring to Power SupplyCAUTION – Wiring to high voltage side of power supply to be accomplished by certified electrician in accordance with NEC or local electrical code.
Trouble-shooting and Maintenance InstructionsCAUTION – Turn off power to the mullion lighting system before removing any covers.
The following items can be replaced in the field:- 60W Power Supplies- LED flex strips (access to end of unit required)
TROUBLE-SHOOTING- If an entire strip of LEDs are not lighted (one of the two strips for a center unit or the one strip
of an end unit), either there is a wiring problem to that strip or the LED driver is defective.- Check wiring connections to the unit at the driver. If the connections look OK, proceed to
“Replacement of LED Driver”.- If both LED strips are not lighted on a center unit or the single strip isn’t lighted on an end-unit,
it is possible that power to the unit has been interrupted. Confirm that the cable to the unit is wired properly and securely to the DC power source.
Replacement of LED Flex Strip- Remove the 2, #4 screws securing the end-cap where the cable exits the unit. - Slide out the lens on the side of the defective LED flex strip.- Cut the two wires from the defective LED flex strip about 6” from the end of the strip.
CI-101 Rev. A Page 3 4/25/2012
10 Technology Dr., Peabody, MA 01960 978-818-6180 978-818-6181 fax
- Remove the defective LED flex strip by peeling away from the housing.- Install the new LED flex strip by peeling the release tape and sticking to the housing. Start at
wired end positioning start of strip about 1” from end of housing. Continue down the full strip, pressing in between components to insure a good bond.
- Connect Red and Black wires to the wires previously cut. Attach using twist on wire nuts.- Push the wire nuts inside extrusion.- Slide in lens which was previously removed. Re-attach end-caps with 2 #4-40 screws
previously removed.
Fixture Cleaning Instructions- The lens and aluminum housing should be cleaned periodically with a mild liquid dish
detergent.- Do not use chemical cleaners on the lens.- Keep the outside clean. Wipe with a clean cloth lightly dampened with mild liquid dish
detergent. Dry with a clean, soft cloth. Do not use scouring pads, powdered cleaners, bleach or cleaners containing bleach because these products can scratch and damage the finish.
Door Configurations The ILT-CEN-60-24, 60W, 24VDC power supply can power up to 3 Center units. Here are three typical door configurations and the number of power supplies required for each.
# of Doors # of Center Units
# of End Units # of Power Supplies
Notes
3 2 2 14 3 2 2 2 Centers-1 End; 1 Center-1 End5 4 2 2 2 Centers-1 End per P.S.
6 5 2 32 Centers-1 End per P.S. It is possible to wire 2 Centers and 2 Ends on 1 P.S.
CI-101 Rev. A Page 4 4/25/2012
10 Technology Dr., Peabody, MA 01960 978-818-6180 978-818-6181 fax
Page 1 of 4
www.atgelectronics.com Toll free: 877-461-5333 E-mail: [email protected]
ATG Electronics® T8 LED Tube(IPS)
USER GUIDE
NOTE:
Please read this entire manual to fully understand and safely use this product.
Specifications are subject to change without notice. Please visit www.atgelectronics.com for the most
recent user guide versions.
Included in this Box
ATG Electronics® iBright™ T8 LED Tube (IPS), 1 PCs
Wire Nuts, 3 PCs
User Guide, 1 Set
Important Instructions
1."NOT FOR USE IN TOTALLY ENCLOSED LUMINAIRES", "NE CONVIENT PAS À DES LUMINAIRES
TOTALEMENT FERMÉS", "DO NOT USE WITH DIMMERS", "NE PAS UTILISER AVEC DES
GRADATEURS","THIS DEVICE IS NOT INTENDED FOR USE WITH EMERGENCY EXITS", "NE
CONVIENT PAS AUX SORTIES DE SECOURS".
2. The LED tube works directly at 100~277VAC. The installer must determine whether they have
100~277VAC at the luminaire before installation.
3. WARNING – Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of
luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
4. WARNING – Risk of fire or electric shock. Install this kit only in the luminaires that have the
construction features and dimensions shown in the photographs and/or drawings.
5. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit
installation.
6. WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or
other sharp objects.
7. WARNING: To avoid potential fire or shock hazard, do not use this retrofit kit in luminaires employing
shunted bi-pin lampholders. Note: Shunted lamp holders are found only in fluorescent luminaires with
Instant-Start ballasts. Instant-start ballasts can be identified by the words “Instant Start” or “I.S.” marked
on the ballast. This designation may be in the form of a statement pertaining to the ballast itself, or may
be combined with the marking for the lamps with which the ballast is intended to be used, for example
F40T12/IS. For more information, contact the LED luminaire retrofit kit manufacturer.
8. Installers should not disconnect existing wires from lampholder terminals to make new connections at
lampholder terminals. Instead installers should cut existing lampholder leads away from the lampholder
and make new electrical connections to lampholder lead wires by employing applicable connectors.
9. Other warnings will not to lead to misuse.
REV1.1
Page 2 of 4
www.atgelectronics.com Toll free: 877-461-5333 E-mail: [email protected]
PLANNING THE INSTALLATION
Before retrofitting fluorescent luminaires, please make sure the dimensions of existing luminaires
are larger than the dimension noted below.
T8 Luminaire Dimensions: (Unit: mm)
Note:
1. “W” represents the Width of luminaire(s), “L” represents the Length of luminaire(s).
2. If working with one-lamp luminaires, W = min. 100 mm
If two-lamp luminaires, W = min. 300 mm
If three-lamp luminaires, W = min. 450 mm
If four-lamp luminaires, W = min. 600 mm
3. For 0.6m LED Tubes, L= 620 mm
For 1.2m LED Tubes, L=1240 mm
For 1.5m LED Tubes, L=1530 mm
4. This LED tube can only be used in luminaires which contain a maximum of 4 lamps of
0.6 m long and 1.2m long LED tubes, and max. 2 lamps for 1.5m long LED tubes.
ATG Electronics® iBright™ T8 LED Tube (IPS) Specifications
Model Input Voltage Max Wattage Dimension
T8ID06HUZZABBB 100~277 VAC 12W 589mm
T8ID12HUZZABBB 100~277 VAC 23W 1199mm
T8ID15HUZZABBB 100~277 VAC 27W 1499mm
Page 3 of 4
www.atgelectronics.com Toll free: 877-461-5333 E-mail: [email protected]
Retrofit Luminaires with Electronic Ballast
Installation Steps
Step 1: Turn off main power before installation.
For safety, make sure main power source is switched off before attempting to install.
Step 2: Take off existing fluorescent light and disconnect the ballast.
Step 3: Cut four leads of G13 lamp holders. (For detailed placement of the cuts, note the X’s on the
wiring diagram labeled “Before” shown below.)
Step 4: Reconnect lamp holder leads L and N to the supply wires of branch circuit according to the wiring
diagram below. Both G13 sockets of the fixture should be connected to the power source directly.
Step 5: Install fixture as before.
Step 6: Adhere a label to the luminaire to the effect of “This luminaire has been modified and can no
longer operate fluorescent lamps.” on the retrofitted luminaire, where readily visible during relamping.
Step 7: Install the LED tube into the fixture.
Wiring Diagram for Electronic Ballast
Before
CUT CUT
After
Page 4 of 4
www.atgelectronics.com Toll free: 877-461-5333 E-mail: [email protected]
Retrofit Luminaires with Magnetic Ballast
Installation Steps
Step 1: Turn off main power before installation.
For safety, make sure main power source is switched off before attempting to install.
Step 2: Take off existing fluorescent light and disconnect the ballast.
Step 3: Cut the ballast output lead and cut the wirings of the starter. Both the ballast and starter need to
remain in place. (For detailed placement of the cuts, note the X’s on the wiring diagram labeled “Before”
shown below.)
Step 4: Reconnect lamp holder leads L and N to the supply wires of branch circuit according to the wiring
diagram below. Both G13 sockets of the fixture should be connected to the power source directly.
Step 5: Install fixture as before.
Step 6: Adhere a label to the luminaire to the effect of “This luminaire has been modified and can no
longer operate fluorescent lamps.” on the retrofitted luminaire, where readily visible during relamping.
Step 7: Install the LED tube into the fixture.
Wiring Diagram for Magnetic Ballast
Before
CUT CUT
After