com-power cgo-515 datasheet

2
Comb Generator CGO-515 Features Frequency range of 1 MHz to 1.5 GHz Stable Frequency Output Automatic Low Voltage Signal Shutoff Battery Operated Three-Year Warranty The CGO-515 Comb Generator is a conducted and radiated signal reference source. This Comb Generator can produce harmonics at 1 MHZ and 5 MHz. The step size can be selected by a toggle switch. These reference signals are used for validating EMC test sites; therefore the reference signal source must have a stable and precise output. Com-Power’s Comb Generators line is designed to meet this requirement. Due to the broad frequency range, two antennas are supplied with the CGO-515, a 12” antenna for low frequency up to 450 MHz, and 5” antenna for 450 MHz and above. The radiated signals are generated by connecting one of the two antennas to the BNC connector located at the center of the CGO-515. The circular chassis of Comb Generator helps radiate the signal more uniformly in all directions within the same plane. The conducted reference signals can be obtained by connecting a Coaxial Cable between the BNC connector mentioned above and a Spectrum Analyzer. The CGO-515 is powered by an enclosed rechargeable battery pack to minimize disturbances of external cables that might interfere with the radiated signal. When the battery voltage reaches below the operating level, the output signal will shut off automatically to prevent further use and misleading data. When fully charged, the battery allows continuous use of the Comb Generator for up to 18 hours. EMI measurements are usually collected in an Open Area Test site (OATS) or inside an Anechoic Chamber. OATS and chambers must be calibrated before put into service using published calibration procedures at regular intervals. These calibration methods are very elaborate and time consuming to be performed before each test to ensure that the data taken is consistent and accurate. The CGO-515 is a quick Site Verification tool that the test engineer can use to detect potential problems with site. Maintaining a log of the Comb Generator radiated readings, prior to taking measurement from a product in the same setup, and comparing them will help in detecting possible faults. The same process can be utilized when emissions measurements that are taken from the same products varies on a repeated test. It is difficult to determine if it is the test site or the product causing the variation. Using the same test setup, measurements can be taken with a Comb Generator in place of the product. This data can be compared with previous Comb Generator measurements to determine the problem. Other uses of the Comb Generator include testing cables and filters. Com-Power Corporation 19121 El Toro Rd., Silverado, California 92676 (949) 459 - 9600 www.com-power.com Description Application Rev. D12.14

Upload: hahanh

Post on 03-Jan-2017

237 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Com-Power CGO-515 Datasheet

Comb GeneratorCGO-515

FeaturesFrequency range of 1 MHz to 1.5 GHz

Stable Frequency Output

Automatic Low Voltage Signal Shutoff

Battery Operated

Three-Year Warranty

The CGO-515 Comb Generator is a conducted and radiated signal reference source. This Comb Generator can produce harmonics at 1 MHZ and 5 MHz. The step size can be selected by a toggle switch. These reference signals are used for validating EMC test sites; therefore the reference signal source must have a stable and precise output. Com-Power’s Comb Generators line is designed to meet this requirement.

Due to the broad frequency range, two antennas are supplied with the CGO-515, a 12” antenna for low frequency up to 450 MHz, and 5” antenna for 450 MHz and above. The radiated signals are generated by connecting one of the two antennas to the BNC connector located at the center of the CGO-515. The circular chassis of Comb Generator helps radiate the signal more uniformly in all directions within the same plane. The conducted reference signals can be obtained by connecting a Coaxial Cable between the BNC connector mentioned above and a Spectrum Analyzer.

The CGO-515 is powered by an enclosed rechargeable battery pack to minimize disturbances of external cables that might interfere with the radiated signal. When the battery voltage reaches below the operating level, the output signal will shut off automatically to prevent further use and misleading data. When fully charged, the battery allows continuous use of the Comb Generator for up to 18 hours.

EMI measurements are usually collected in an Open Area Test site (OATS) or inside an Anechoic Chamber. OATS and chambers must be calibrated before put into service using published calibration procedures at regular intervals. These calibration methods are very elaborate and time consuming to be performed before each test to ensure that the data taken is consistent and accurate. The CGO-515 is a quick Site Verification tool that the test engineer can use to detect potential problems with site. Maintaining a log of the Comb Generator radiated readings, prior to taking measurement from a product in the same setup, and comparing them will help in detecting possible faults. The same process can be utilized when emissions measurements that are taken from the same products varies on a repeated test. It is difficult to determine if it is the test site or the product causing the variation. Using the same test setup, measurements can be taken with a Comb Generator in place of the product. This data can be compared with previous Comb Generator measurements to determine the problem. Other uses of the Comb Generator include testing cables and filters.

Com-Power Corporation 19121 El Toro Rd., Silverado, California 92676 (949) 459 - 9600 www.com-power.com

Description Application

Rev. D12.14

Page 2: Com-Power CGO-515 Datasheet

Comb GeneratorCGO-515

Com-Power Corporation 19121 El Toro Rd., Silverado, California 92676 (949) 459 - 9600 www.com-power.comRev. D12.14

Specifications

All specifications are subject to change without notice. All values are typical, unless specified.

0

10

20

30

40

50

60

70

80

90

100

0 100 200 300 400 500 600 700 800 900 1000

Am

plitu

de (d

BuV/

m)

Frequency (MHz)

COMB GENERATOR OUTPUT (amplitude vs frequency)

0

10

20

30

40

50

60

70

80

90

100

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000

Am

plitu

de (d

BuV/

m)

Frequency (MHz)

COMB GENERATOR OUTPUT (amplitude vs frequency)

1 MHz Step Size

5 MHz Step Size

Intended Application EMI Radiated Site Reference SourceFrequency Range 1 MHz to 1.5 GHzFrequency Step Size 1 MHz and 5 MHzFrequency Stability 50 ppmAmplitude Stability ± 0.1 dBTime Stability <1 dB over 12 monthsCharger Output / Input 6 VDC, 500 mA / 110VAC 60 Hz or 230 VAC 50 HzBattery Type 6V NiMH, 1 AhOperating Time >18 Hours Typical With Fully Charged BatteryExternal Indicators Battery Low and Power OnAntenna Size 5 and 12 inch MonopoleDimensions 7 x 0.75 inches / 17.7 x 1.9 cmWeight 2 lbs. / 0.9 kgPolarization Vertical and Horizontal

Radiated Data: 3 meters, vertical polarization, antenna height varied from 1 to 4 meters.