Page 1: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

AP-MSM-08All Product Catalogue

Chilled Water System Solution

Page 2: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

CONTENTS:

Chilled Water System SolutionMcQuay Offers ; Comprehensive Solution ........................ 2 In Air Conditioning Needs

Features Of McQuay Chilled Water Products ................... 3

Smart Manager ................................................................. 4

McQuay Air Cooled Mini Chiller Series ............................. 7

Tandem Compressors Air-Cooled Mini Chiller ................ 12

Inverter Mini Chiller ......................................................... 13

McQuay Chilled Water Fan Coil Units ..............................15

NIM & NIM PC Networking Control System .....................16

McQuay Chilled Water Fan Coil Units Range ..................17

SpecificationsMini Chiller Specifications ............................................... S1

Chilled Water Fan Coil Unit Specifications ..................... S6

Page 3: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

MinneapolisMinneapolis

FaribaultFaribaultOwatonnaOwatonna

StauntanStauntan

Mexico CityMexico City

AuburnAuburn

CramlingtonCramlington

CecchinaCecchina SuZhouSuZhou

WuhanWuhan

ShenZhenShenZhen

Sungai BulohSungai Buloh

CikarangCikarang

Manufacturing Plant

GLOBAL DISTRIBUTION NETWORK

Americas• USA • Puerto Rico • Mexico • Paraguay • Uruguay • Guadaloupe •

Oceania• Australia • New Zealand •

Middle East & Africa• Jordan • Lebanon • Oman • Qatar • Saudi Arabia • Bahrain • Morocco • Iraq • U.A.E. •

• Mauritius • South Africa • Kenya • Madagascar • Ghana • Nigeria • Tanzania •

Europe• England • Greece • Hungary • Italy • Norway • Poland • Portugal • Russia • Spain •

• Belgium • Tunisia • Croatia • Cyprus • Lithuania • Malta • Slovenia • Ukraine •

• Turkey • Finland • Czech Republic • Romania •

Asia• Cambodia • China • Hong Kong • Indonesia • Maldives •

• Malaysia • Singapore • Thailand • Vietnam • Pakistan •

Page 4: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

Product Overview

Model Range

Cooling Capacity (kW)

Heating Capacity (kW)

Electrical Supply

R22 MAC 020/025/030 C/CR

5.0 - 8.1

MAC 040/050/060 C/CR

M4AC 020/025/030 C/CR M4AC 040/050/060 C/CR

M5ACV 030 CR M5ACV 055/075 CR

MWM 007/010/015/020 GWMWM 301W MCK 020/025/030/040/050 AW

2.34-5.28

3.02-6.74

6.62-10.80

8.40-12.90

M5AC 020/025 CR

11.7 - 15.5

5.9 - 9.5 12.6 - 17.5

R407C

R410A

R410A Inverter

50Hz

60Hz

Model Range

Cooling Capacity (kW)

Heating Capacity (kW)

Electrical Supply

Model Range

Cooling Capacity (kW)

Heating Capacity (kW)

Electrical Supply50Hz

50Hz

60Hz

60Hz

MCM 007/010/015 CBW MCM 020/025/030/040/050 DW

1.90-3.08 5.19-13.19

2.28-4.19 6.45-15.10

Page 5: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

MAC 080/100/120/150/210 C/CR

M4AC 080/100/120/150/210 C/CR

M5ACV 100/135/210 CR

MCK 020/025/030/040/050 AWH

3.81-5.16

MCK 015/020/025 BW MCK 010/015/020 CW

3.66-5.27 2.34-4.25

10.55-13.77 4.69-6.15 3.22-5.42

M5AC 030/040/050/055 CR

21.6 - 58.6 7.3 - 14.9

26.4 - 61.5 9.8 - 18.0

MCC 010/015/020/025/028 CWMCC 030/038/040/050/060 CW MDB 075/100/125/150 BWMCW 200/300/400/600 C/H

MCW 800/1000/1200 C/H

2.9-15.8 2.1-4.6

5.6-32.2 4.7-9.6

Page 6: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

INTRODUCTION

McQuay is committed to offer you with the better solution in

your air conditioning needs. In the new series of chilled water

products, McQuay is not just offering you with wide range of

chilled water air conditioning equipments, but a better solution

from selecting the equipments, designing the water piping

systems to provide easy control of the complete chilled water

system. This is facilitated by the user friendly computer

selection programs and remote monitoring of the operation of

complete system through the Smart Manager.

The series of chilled water product has incorporated the technology of advanced communicating controls,

microprocessor controlled chillers with a wide range and variety of fan coil unit that offers total flexibility.

McQuay Offers ;Chilled Water System

2

Page 7: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

McQuay Chilled Water Series Of Products

FEATURES

Year Round Comfort

Can be used in variety of climates with systems that

are available in two versions, cooling only and heat

pump.

Reliable and More Efficient

The refrigerant of the system is confined to within

the chiller itself and therefore no refrigerant is

circulating throughout the building. This will be no

risk of refrigerant leakages in building or risk of poor

oil return that will damage compressor caused by

poor installation.

Multiple compressors in McQuay chiller series offers

stages capacity control that will offer better

efficiency.

Long Piping Applications

McQuay chilled water system avoids the limitation

of piping lengths and bends that exist in Direct

Expansion refrigerant system. The chiller can be

installed far away from the fan coil units, thus

offering flexibility and creativity in the installation.

Quality, Innovative and Compact Design

McQuay chiller is equipped with reliable and quality

components.

Multiple Temperature Zone Control

The operation of the fan coil units can be managed

independently by zones according to similar air

conditioning comfort needs.

3

Page 8: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

By adopting the McQuay chilled water system, the comfort in

residential and light commercial buildings such as offices, hospital,

restaurant, hotel and shopping complex can be controlled and

managed from just one point, that is through the Smart Manager.

The Smart Manager is acting as a center to manage the operation of

both the chilled water fan coil units and the chillers.

Besides allowing the user to have customized control for each

connected unit, the Smart Manager is also able to manage the overall

system operating mode of all units based on the air conditioning

system load demand of the building.

Chiller Network BUS Fan Coil Network BUS

Through the versatile Smart Manager controller, the operation of

each equipments in the McQuay chilled water system connected

through the chiller Bus and McQuay own proprietary NIM BUS can

be managed and controlled.

Supported Up To 50 Chillers & 120 Fan Coil Units

FEATURES

Controller

4

Page 9: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

Alarm 1

(Ch 0)

Comp 1 overload

01/01/00 12.00am

Display Up To 46 Types Of Chiller Fault/Alarm And 6 Types Of FCU Fault/Alarm

Whenever a fault occurred in either the chiller or fan coil unit, a signal will be

sent to Smart Manager and an alarm message will appear on the LCD,

showing type of alarm, alarm occurred time, date and unit.

This will greatly ease the troubleshooting process and thus reduce the

valuable time of service technicians.

As soon as the fault is being solved, the alarm will automatically dissolve from

the LCD.

Priority Settings

Depending on the application requirement, the Smart Manager offers the flexibility to allow user to set the priority on

the operation of fan coil unit and chiller in a complete McQuay chilled water product system.

If priority is set to Fan Coil Unit, the chiller will be forced to OFF if all fan coil units are OFF. If Chiller Priority is being

set, all fan coil units will be OFF if chillers are OFF.

Threshold Value Setting

If the priority setting is being preset to fan coil unit, the operating mode of the complete McQuay chilled water system

can be synchronized to operate under one same mode. This is achievable through the unique feature called

“Threshold Value Setting”

Smart Manager can command chiller operating mode to switch from current operating mode if the threshold value is meet.

Example,

In a network of 10 fan coil units that is currently operating in COOL mode and a threshold of 60% was set for COOL

mode and threshold of 50% was set for HEAT mode. Should 6 of the fan coil units are requesting for HEAT mode then

the threshold for HEAT is crossed. Signal will be sent by Smart Manager to chiller BUS to switch the operating mode

of all chillers to HEAT mode. Requirement of users will be met.

• Heat Treshold •

Chiller to operate at Heat Mode

Chiller to operate at Cool Mode

0 1 2 3 4 5 6 7 8 9 10

• Cool Treshold •

5

Page 10: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

HOLIDAY SETTINGS

Holiday 1Holiday 2Holiday 3Holiday 4Holiday 5

MWM

MCM 2MCK

MCC

MCM 1

Energy Saving Programmable Timer

The operation of the chiller and each fan coil unit

can be preset to operate and to stop at different

time schedule and at different day of a week. Taking

consideration of the fact that certain rooms in a

building will be empty at certain period of the day,

setting timer to On and to Off the operation of units

in those areas will greatly reduce the energy cost of

the building.

At the same time, Smart Manager allows setting up to

five sets of 7 days programmable operating schedules

(2 On/Off timer per day) for each fan coil unit.

Holiday Setting

While designing the Smart Manager, the practical

aspects of equipment application were always the

key points to be considered. Thus resulting in the

creation of “Holiday Setting” feature.

In this feature, users are allowed to set up to 10

holiday timers with each timer can last for duration

of 99 days.

During the duration of Holiday Timer set earlier, all fan

coil units and chiller will automatically be turned Off.

Set Holiday 1

Month : 1Day : 1Duration : Disable

8.00am

9.00am

10.00am

11.00am

12.00am

1.00pm

2.00pm

3.00pm

4.00pm

5.00pm

6.00pm

7.00pm

8.00am

9.00am

10.00am

11.00am

12.00am

1.00pm

2.00pm

3.00pm

4.00pm

5.00pm

6.00pm

7.00pm

Time

MCC

MCK

MCM2

MCM1

MWM

Un

it

6

Page 11: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

Memory Backup (EEPROM), Alarm Memory for Chiller and FCU

When there is power failure occurs during

operation, Smart Manager will load the last state

memory from EEPROM after power On reset.

Besides, extra memory space inside the Smart

Manager will allow user to view the previous alarm

records even though its have been dissolved. This

useful information will benefit the service

technician to view the history of maintenance

record done to the unit.

Password Protection For Advanced Parameter Settings (Chiller)

A McQuay chilled water product system with key

parameters that were set by personal to optimize

operating conditions will need to be protected

against any unauthorized disturbance or changes.

The built in “Password Settings” feature will prevent

the losing of key parameter settings in the Smart

Manager.

Low Power Mode (Chiller + FCU)

Smart Manager will turn into low power mode during

electricity power breakdown. It will operate based

on the built in backup battery and only one timer

and interrupt is active. CPU operation is Off and no

display on LCD as well for energy saving purpose.

Key Parameter Display

For easy serviceability and maintenance, Smart

Manager is able to display the key parameter such

as defrost and compressor discharge sensor

temperature, water in/out temperature, status of

compressor On/Off, Cool/Heat mode water in

temperature, etc. Thus, it reduces the cumbersome

of requiring the service technicians to physically go

to site of chiller installation to do the

troubleshooting process.

Accumulative Compressor Run Time

User can also check the compressor run time of

chiller in Smart Manager. It will provide a guideline

as well as posting a reminder for requirement of

routine system service.

Multiple Temperature Zone Control

The operation of the fan coil units can be managed

independently by zones according to similar air

conditioning comfort needs.

Real Time Clock (RTC)

RTC will always appear at the summary pages and

the user is able to set the time and date.

7

Page 12: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

McQuay offering you the range of air cooled chiller that is suitable for many applications from residential to

commercial.

McQuay Air Cooled Mini Chiller Series

The McQuay chiller is incorporated with the basic

necessary components such as circulating water

pump, expansion tank, compact brazed plate heat

exchanger, differential pressure switch and the

microprocessor controller and wired control panel.

In addition, the selection of the McQuay chiller could

not be more easy than the user friendly yet versatile

selection softwares for chiller as well as connecting

piping.

In short, Smart Manager Chilled Water Product Range

offers you the better solution to your chilled water

product needs.

8

Page 13: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

Model :MAC 040/050/060 C/CRM4AC 040/050/060 C/CRM5ACV 055/075 CR Capacity :Cooling : 11.7 kW to 15.5 kWHeating : 12.6 kW to 17.5 kW

Refrigerant : R22, R407C, R410A

Model :MAC 020/025/030 C/CRM4AC 020/025/030 C/CRM5AC 020/025 CRM5ACV 030 CR Capacity :Cooling : 5 kW to 8.1 kWHeating : 5.9 kW to 9.5 kW

Refrigerant : R22, R407C, R410A

PRODUCT RANGE

Model :M5AC 030/040/050/055 CR Capacity :Cooling: 7.3 kW to 14.9 kWHeating: 9.8 kW to 18.0 kW

Refrigerant : R410A

9

Model :MAC 080/100/120/150 C/CRM4AC 080/100/120/150 C/CRM5ACV 100/135/210 CR Capacity :Cooling : 21.6 kW to 58.6 kWHeating : 26.4 kW to 61.5 kW

Refrigerant : R22, R407C, R410A

Page 14: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

Compactness

The MAC/M4AC 020~030 C/CR is such a compact

unit that it can be integrated perfectly with any

architectural design, making it an ideal choice for

house, offices, restaurant and shop.

Scroll Compressor

Scroll Compressors are used for the units to offer a

quieter and more reliable performance over a wide

operating temperature range. (Except MAC/M4AC

020 C/CR which uses rotary compressor).

For MAC/M4AC 030, 040, 050, 060, 080, 100, 120,

150 CR, phase protector is provided to prevent the

compressor from rotating in the wrong directions.

Microprocessor Control

McQuay chillers are equipped with microprocessor

controller that will control and regulate the operation

of the unit.

Besides, the controller that contains the well

developed algorithm will provide protection to the

chiller by accurately sensing the key temperatures

in both the water and refrigerant circuit. Should

there be any abnormal reading received by

controller, an alarm signal will be sent to chiller

panel, followed by protection action plans such as

to stop the operation of compressor, condenser fan

motor or circulating water pump.

Partial Loading

Models MAC/M4AC 080~150 C/CR has been

designed with two separate refrigerant circuits, i.e.

it has two compressors. By doing so, the unit has

part loading capabilities, i.e. 0-50-100% of rated

capacity. This will improve the reliability and energy

efficiency of the unit, especially during low loading

operations.

Fully Equipped Chillers

McQuay chiller is fully integrated and equipped with

key hydronic components such as expansion tank,

water tank, brazed plate heat exchanger and water

circulating pump. The all in one concept will ease

the job of installer.

Brazed Plate Heat Exchanger

The heat exchanger is made of AISI 316 stainless

steel plates closely arranged and brazed together to

maximize possible heat exchange efficiency.

FEATURES

10

Page 15: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

Availability Of Connection To Boiler

The microprocessor controller has a built in control

algorithms that allowed the chiller to be connected

to the boiler. By adding a boiler to the system, it can

either work as the sole heating water source in a

Cooling only unit or it can act as the booster heat

source to the Heat Pump chiller.

Safety Protection

The safety protections provided for the McQuay

chiller are:

• High & Low Pressure Switches

• Anti-Freeze Protection Sensor

• Discharge Temperature Sensor

• Over Pressure Relief Valve

• Water Pressure Differential Switch

• Anti-Freeze Heater on BPHE

• Compressor Water Pump &

Fan Motor Overload Protector

Anti-Freeze Protection

The chiller unit has several anti-freeze protection

features:

1. Built-in heater in BPHE

The BPHE has a strip heater around it to

prevent water freezing inside.

2. Anti-Freeze sensor

BPHE can avoid the frosting as the anti-

freeze sensor will send the signal to cut out

the compressor if the water temperature

becomes too cold.

3. Water pressure differential switch

This protection feature will ensure there is

water flow in pipings when the chiller is in

operation. Otherwise, the compressor will

cut out immediately.

Water In Water Out

Up to 50Chillers

Chiller Bus

11

Sequencing Control

For MAC/M4AC 080~150 C/CR, both compressors

will cut in and cut out depending on their

accumulative operating time. This sequencing

control feature will ensure no single compressor is

overload in operation as well as to ensure longer

reliability of compressors.

Modular Installation

The mini chillers are available for modular

connection. A network of up to 50 chillers in a

system is possible. Control on the operation of the

chillers will be done through the microprocessor

controller. The external water piping connection can

be made either from the left or right side of the unit.

Page 16: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

FEATURES

Easy Installation And Maintenance

As a chiller, all hydronic components are assembled

and wiring jobs on chillers are done and tested in the

factory. Installation of additional component on site

can be eliminated.

In addition, unit operation is user friendly and

maintenance is simple. By opening the front panel,

you would have immediate assess to all

components.

Factory Precharged Refrigerant

Each heat exchanger in the chiller is brazed and

tested against leakages through dried air at 30 bars.

After that, another process to vacuum the system

before accurately charged with refrigerant to ensure

optimum performance. Thus, it saves the hustles of

field charging by installers.

Anti Corrosion Heat Exchanger

The condenser heat exchanger of chiller, heat pump

specification, utilize the special anti corrosion gold

aluminum fin.

R407C & R410A

In line with Montreal Protocol, the Smart Manager is

available in R407C & R410A refrigerant.

* R407C & R410A is having Zero Ozone Depletion

Potential (O.D.P). However it is gas whose Global

Warming Potential (GWP) is similiar to the high

GWP for R22.

Brazed Plate Heat Exchanger

The heat exchanger is made of AISI 316 stainless

steel plates closely arranged and brazed together to

ensure high heat exchange efficiency.

Chiller Control Panel

The chiller panel controller is designed to control the

chiller operation. This device allows the user to have

customized control for each connected unit.

Each chiller will have a chiller control panel that

comes as a standard accessory. At the same time,

the chiller control panel is able to be installed

remotely through the cable up to a distance of 100

meters. Example, the chiller panel can be installed in

a centralized plant control room for the building.

The chiller control

panel has been

designed taking

into consideration

of the user friendly

and yet versatile

control features.

Features:

• Whole system configuration.

• Unique parameter settings.

• Operation status display.

• Tracing fault record (offer quick troubleshooting

solutions).

• The display is shown in an 8-lines graphical LCD

display. There are 8 dedicated keys available in

the panel.

• Menu selection.

• Navigation on the screen.

• Modification of the selected value.

12

Page 17: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

Air - Cooled Mini Chiller

This new line of innovative air cooled chiller by McQuay was designed with one purpose in mind, which is to offer user

with cost and energy saving for users.

Better Performance

• Usage of higher efficient R410A rotary compressors

in tandem configuration

• Tight tolerances between moving parts resulting

in high compressor volumetric efficiency

• Minimize mechanical losses

• Minimize gas flow losses and turbulence

• Optimize compressor oil return

Capacity Step Control

• 3 steps compressor loading (0%-40%-60%-100%)

for M5AC 040 CR & M5AC 050 CR

• 2 steps compressor loading (0%-50%-100%) for

M5AC 030 CR & M5AC 055 CR

Sequential Control

• Both compressors will cut in cut out depending

on water temperature. This is possibly improving

the compressor life cycle as well as the

compressor reliability. Elimination of Water Tank

• Combining the Tandem Compressors

technology with the algorithm of the

microprocessor control, water tank can be

eliminated in most instances.

Choices of Single Phase and 3 Phase Power Supply Connection

• Usage of single phase power supply compressors

and circulating water pump.

• Offers flexibility to field installation.

TANDEM COMPRESSORS

13

Page 18: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

The new series of Inverter Mini Chillers are specially designed / developed to achieve better system energy saving

as well as towards perfect control during part load condition.

Built In Fan Speed

Fan speed is now controlled by the built in

algorithm, resulting in cost saving since installation

of external FSC (Fan Speed Controller) can be

exempted. It is regulated at 100%, 70% and 50%

based on the ambient and outdoor condensing

temperature.

Safety Protection

• High & Low Pressure Switches

• Anti-Freeze Protection Sensor

• Discharge Temperature Sensor

• Over Pressure Relief Valve

• Water Pressure Differential Switch

• Anti-Freeze Heater on BPHE

• Compressor, Water Pump Overload Protector

Anti Corrosion Heat Exchanger

Gold Aluminum fin is offered as the standard

material of the condenser heat exchanger of this

series of chiller.

True Dual Circuits BPHE

Apply sophisticated technology of true dual circuit

BPHE.

The true dual BPHE puts the secondary circuit

(water) in contact with 2 primary circuits

(refrigerant). So even if one primary circuit is shut

off, each secondary channel is still in contact with a

primary channel. These advantages have made the

product the natural choice for flexible chillers,

climate control applications and high-precision

systems food cooling cabinets in supermarkets.

Inverter Compressor

Inverter compressor is programmed to run at the

optimum speed, which is regulated by the input

frequency as it can varies according to the heat

load requirement.

water

Ref.1 Ref.2 Ref.1 Ref.1Ref.2

waterwater water

PrimaryCircuit 1

PrimaryCircuit 2

Water In

Water Out

14

Page 19: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

Modular Installation

A network up to 50 chillers in a system is possible.

Control on the operation of the chillers will be done

through the microprocessor controller. The external

water piping connection can be made either from the

left or right side of the unit.

Chiller Panel Comes AsThe Standard Controller

Compatible WithSmart Manager

Inverter System Conventional System

Precise & Stable Temperature Control

Fast Cooling

RoomTemperature

SetTemperature

SetTemperature

RoomTemperature

Time

Time

Advantages of inverter compressor applications are:

LESS START & STOP

Frequency regulated compressorresulting in lesser

in the sense of start and stop of compressor, which

is greatly reduce the energy consumption.

FAST COOLING / HEATING

Unlike the other conventional systems, inverter

compressor has the ability to produce faster cooling /

heating capacity at the frequency higher than the

dominant capacity frequency.

BETTER COMPRESSOR RELIABILITY

Reliability of inverter compressor is always better

since there is lesser ON/OFF of the system

especially during the low load condition.

LOW STARTING SURGE

Inverter compressor require lower starting torque

and thus, resulting in lower starting current.

Elimination Of Water Tank

Inverter system provide constant water temperature

band, or much lesser water temperature fluctuation.

With this, water tank of the mini chiller system can

be eliminated.

15

Page 20: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

McQuay Chilled Water Fan Coil Units

To complement the new innovative Smart Manager range of air cooled chillers, McQuay is offering an extensive

range of chilled water fan coil units that will meet most of indoor application requirements covering residential, light

commercial and commercial.

The aesthetically attractive decorative fan coil units such as Wall Mounted models, Ceiling Cassette and Ceiling

Convertible is compact and ergonomic, the ranges can blend in easily to any interior designs whether it is

residential houses, office, restaurant or shops.

In addition, the McQuay chilled water fan coil units are designed with easy installation and easy servicing in mind.

The fan coil units also include the microprocessor controller that has built in algorithm to control the operation of the

fan coil unit as well as to provide protection to the unit.

16

Page 21: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

For NIM PC only

NIM

NIM

NIM NIM NIM NIM

NIM NIM

NIM

NIM PC for Global Control HubWith NIM PC, a personal computer will act as a centralised unit for both controlling and monitoring of all the air

conditioning units in the HydroNIM network.

For controlling, settings can be set from the PC and send out to the system for execution. While for monitoring,

there is a graphical user interface for displaying the status of each unit.

The NIM PC provides a Global Control Hub that offers control for better system management:

• Easy to operate full graphical user interface.

• Control units globally, as a group,

or as individual units.

• Configure a super master unit.

• Support up to 42 On/Off timers per week.

• Real time monitoring of online units.

• Error diagnostic and alerting features for all units.

• Data logging and printing ability.

• Database to store unit location.

• Login protected by password.

NIM Networking Control System (optional)

For multiple fan coil unit installation in an office, a centralised controlled operation can be achieved through the

McQuay proprietary NIM networking system.

Network Interface Module (NIM) is a networking system which enables communication among McQuay air

conditioners.

With the NIM, all your air conditioning systems can be controlled with just a single controller giving you boundless

benefits:

BENEFITS

• Ultimate convenience. No more individually controlling air conditioning units

• Quick and easy zone control from the master control unit

• Better control of air conditioning systems operating conditions

NIM utilizes master-slave type system whereby the master node will issue commands to each of the slave nodes.

17

Page 22: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

McQuay Chilled Water Fan Coil Units Range

MWM 07/10/15/20/25 GW

MWM 301 W

• Slim and compact• Wide capacity range • Wide air flow range• Incorporated with NanoGuard.• Able to communicate with the versatile NIM for fan coil

units networking • Light weight• Detachable and washable air intake grille• Microprocessor control• Self diagnosis features• Automatic air swing• Wireless Control as standard• Mode selection, fan speed, 24 hours real timers• Optional wired controller

Wall Mounted Range

Features :

SLM Wired Controller

AC-5300WirelessController

OPTIONAL

G17 WirelessController

STANDARD

2 Pipes System:MCK 020/025/030/040/050 AW

4 Pipes System:MCK 020/025/030/040/050 AWH

MCK 015/020/025 BW

Ceiling Cassette Range

Features :

• 3 range of ceiling cassette to be chosen from. - MCK-CW - 570mm (w) x 570mm (l)- MCK-BW - 650mm (w) x 650mm (l)- MCK-AW - 820mm (w) x 820mm (I)

• Aesthetically attractive and slim front panel• 4 way air discharge to provide better air distribution to room• Automatic air swing• 4 pipes system is available for model

MCK020/025/030/040/050AWH • Easy servicing and maintenance• Built in high pressure head drain pump

- Ability to pump up condensate water to 700mm high• Built in water float switch to protect the unit from problems

of condensate water overflow• Microprocessor control• Able to communicate with the versatile NIM for fan coil

units networking• Self diagnosis feature• Wireless Control as standard

- Mode selection, fan speed, 24 hours real timers• Optional wired controller

OPTIONAL

Netware III Wired Controller

18

MCK 010/015/020 CW

STANDARD

G17 Wireless Controller

Page 23: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

MCC 010/015/020/025/030/040/050/060 CW

MCC 028/038 CW

Ceiling Concealed Range

Features :

• Wide capacity range• 4 speed fan motor offers flexibility for installation to suit

application- Each speed will offer different external static pressure and

air flow• High External Static Pressure is available up to 18mm • Extra secondary drain pan to provide protection against

condensate water leaking• Availability of various optional duct accessories specially

designed to fit to MCC-CW range• Microprocessor control• Filter adaptor kit of 1 inch is available as optional accessory • Able to communicate with the versatile NIM for fan coil units

networking• Self diagnosis feature• Wired Control as standard

- Mode selection, fan speed selection

OPTIONAL

Netware III Wired ControllerSLM Wired Controller

STANDARD

MCM 020/025/040/050 DW

MCM 15/20/25 EW

• Ceiling Convertible feature offers flexibility on installation- Installation method of under ceiling or floor standing

• 2 way air discharge ensure better air distribution- Horizontal air throw and bottom air throw

• Automatic Air swing• Aesthetically attractive with round profile outlook fits into to

any indoor architectural• Strong air flow volume and strong air throw distance makes it

a perfect choice for light commercial such as restaurant and shop

• Microprocessor control• Able to communicate with the versatile NIM for fan coil units

networking• Self diagnosis feature• Wireless Control as standard

- Mode selection, fan speed, 24 hours real timers• Optional wired controller

Ceiling Convertible Range

Features :

19

MCM 007/010/015 CBW

SLM Wired Controller

AC-5300WirelessController

OPTIONAL

G17 WirelessController

STANDARD

Page 24: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

20

Optional Accessories (MCC010CW~MCC025CW)

• Wide capacity range• Multiple rooms can be cooled by just 1 unit of MCW• Simple design with easy serviceability feature• Extremely low height of unit – 251mm for complete range• Water piping connection can be easily converted from one

side to the other• Fan motor assembly is not cased, allowing free return or back

return or bottom return with optional return plenum• Availability of optional extended drain to receive the

condensate water dripping from the water piping connection • Availability of 4 pipes MCW series• Other optional accessory available:

- Wired thermostat- Choice of external static pressure (ESP)- Four types of ESP are available: 0Pa, 30Pa, 60Pa, 80Pa.- PTC (Positive Temperature Coefficient) electric heater- 2 way & 3 way valves

Features :

2 Pipes System:MCW 200/300/400/600/800/1000/1200 C

4 Pipes System:MCW 200/300/400/600/800/1000/1200 CH

Features :

• These units are design with high air flow and high external static pressure, enables adequate distribution of air to the desired space

• Multiple rooms can be cooled by just 1 unit of MDB• Simple design with easy serviceability feature• The robust unit is designed with durability and reliability in

mind• MDB125/150BW is using the belt driven fan motor and

blower fan thus it offers flexibility for upgrading should higher air flow is required

• MDB150BW is designed to cater for either horizontal air discharge or vertical air discharge

MDB 075/100/125/150 BW

Return Bracket Assembly come with Adaptor(MCC 010CW - 1 outlet; MCC 015~020CW - 2 outlets)

Y-JointAdaptorDischarge and Return

Supply Grille Assembly come with Adaptor

(Front View)(Side View)

Return Grille Assemblycome with Adaptor

(Front View)

Ceiling Concealed Range

Ducted Blower Range

Page 25: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

21

A new developed thermostat series, AC8000 is now available to be ordered as Chilled Water Fan Coil unit controller, inclusive of AC8000A and AC8000C. Its adopt micro-computer technology and is designed for the easier of installation.

AC8000A practises the most simple and conventional installation method where it consists of a wired controller and a power board. Both of its are attached together while being installed.

Same with AC8000A, AC8000C also consist of a wired controller and a power board, but the power board is attached to the fan coil unit while the wired controller will be installed away from it. Moreover AC8000C has the networking capability, with compatibility to the Network Interface Module (NIM); better control over whole operating system can be achieved as it offers quick and easy zone control from the master operating unit.

Features :• Four Operating Modes

COOL/ FAN/ HEAT/ AUTO• Variable Indoor Fan Speed Selection

High/ Medium/ Low/ Auto• Selectable Function

Cooling Only, Cooling and Heating (2 pipes), Cooling and Heating (4 pipes)• LCD display• LED Indication of Power Supply• 7 days Programmable Timer• Real Timer• Selectable Room Temperature/ Set Temperature Display• Temperature Control Precision up to +/- 1°C• High, Low Voltage Separated for Safety• Last State Memory Backup• Networking Capability (Only Applicable for AC8000C)

AC8000C is compatible with Smart Manager and NIM PC. By using a RS485 cable, it can easily form a NIM bus as described in schematic diagram.

RS485More FCUs

NIM PC

OR

Smart Manager

AC8000CFCU AC8000CFCU AC8000CFCU

LCD Panel LCD Panel LCD Panel

AC80000A AC80000C

AC8000C Series

Page 26: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

S1

Mini Chiller Specifications

MAC020C - MAC060C (Cooling Only, R22)

MAC020C MAC025C MAC030C MAC040C MAC050C MAC060C

Btu/h 18000 23500 27500 40000 50000 53000

W 5275 6887 8059 11723 14654 15533

W 2669 2730 3491 4470 5245 6361

V/Ph/Hz

HEIGHT mm/in

WIDTH mm/in

DEPTH mm/in

kg/lb 116 / 256 123 / 271 128 / 282 195 / 430 196 / 432 203 / 448

dBA 57 57 58 60 60 61

l/s/m3/hr 0.25 / 0.9 0.33 / 1.2 0.39 / 1.4 0.56 / 2.0 0.70 / 2.5 0.74 / 2.7

MAX. WATER OPER. PRESSURE kPa/psi

l/s/m3/hr 0.25 / 0.9 0.33 / 1.2 0.39 / 1.4 0.56 / 2.0 0.70 / 2.5 0.74 / 2.7

INSTALLATION PIPE CONNECITON mm/in

m 8.4 9.7 8.8 9.2 6.8 6.6

L/ft3

1410 / 55.5

1160 / 45.7

460 / 18.1

40 / 1.41

MATERIAL

HEAD

220-240 / 1 / 50 380-415 / 3 / 50

CAPILLARY TUBE

1000 / 145

R22

WATER FLOW RATE

25.4 / 1

0 - 100%

CAPACITY/VOLUME

CAST IRON / STAINLESS STEEL

22 / 0.78

800 / 31.5

1160 / 45.7

460 / 18.1

CONTROL

POWER SOURCE

REFRIGERANT TYPE

MODEL

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

EVAPORATOR

NOMINAL WATER FLOW

UNIT DIMENSION

TANK

PIPING

HYDRAULIC KIT

PUMP

UNIT WEIGHT

SOUND PRESSURE LEVEL

COMPRESSOR

STAGE OF CAPACITY CONTROL (Btu/h)

MAC020CR - MAC060CR (Heatpump, R22)

Notes:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 12ºC / 7ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35ºC AIR AMBIENT TEMPERATURE.b) HEATING - 40ºC / 45ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 7ºC AIR AMBIENT TEMPERATURE.

4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND1m BELOW THE UNIT.

MAC020CR MAC025CR MAC030CR MAC040CR MAC050CR MAC060CR

Btu/h 18000 23000 27500 40000 46000 53000

W 5275 6740 8060 11723 13481 15533

Btu/h 22000 25000 31500 43000 52000 59000

W 6448 7327 9232 12602 15240 17292

COOLING W 2599 2779 3541 4560 5046 6551

HEATING W 2770 2614 3561 4629 4999 6247

V/Ph/Hz

HEIGHT mm/in

WIDTH mm/in

DEPTH mm/in

kg/lb 116 / 256 123 / 271 128 / 282 195 / 430 196 / 432 203 / 448

dBA 57 57 58 60 60 61

COOLING l/s/m3/hr 0.25 / 0.9 0.32 / 1.2 0.39 / 1.4 0.56 / 2.0 0.64 / 2.3 0.74 / 2.7

HEATING l/s/m3/hr 0.31 / 1.1 0.35 / 1.3 0.44 / 1.6 0.60 / 2.2 0.73 / 2.6 0.83 / 3.0

MAX. WATER OPER. PRESSURE kPa/psi

COOLING l/s/m3/hr 0.25 / 0.9 0.32 / 1.2 0.39 / 1.4 0.56 / 2.0 0.64 / 2.3 0.74 / 2.7

HEATING l/s/m3/hr 0.31 / 1.1 0.35 / 1.3 0.44 / 1.6 0.60 / 2.2 0.73 / 2.6 0.83 / 3.0

INSTALLATION PIPE CONNECITON mm/in

COOLING m 8.4 9.9 8.8 9.2 8.2 6.6

HEATING m 6.9 9.4 7.9 8.1 6.0 4.0

L/ft3

220-240 / 1 / 50 380-415 / 3 / 50

CAPILLARY TUBE

0 - 100%

MATERIAL

CAPACITY/VOLUME

CAST IRON / STAINLESS STEEL

22 / 0.78 40 / 1.41

HEAD

WATER FLOW RATE

25.4 / 1

1000 / 145

460 / 18.1

800 / 31.5 1410 / 55.5

1160 / 45.7 1160 / 45.7

460 / 18.1

R22

UNIT WEIGHT

SOUND PRESSURE LEVEL

EVAPORATOR

NOMINAL WATER FLOW

POWER SOURCE

COMPRESSOR

STAGE OF CAPACITY CONTROL (Btu/h)

TANK

PIPING

HYDRAULIC KIT

PUMP

NOMINAL TOTAL INPUT POWER

REFRIGERANT TYPE

CONTROL

UNIT DIMENSION

MODEL

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

Page 27: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

S2

Mini Chiller Specifications

M4AC020C - M4AC060C (Cooling Only, R407C)

M4AC060C

52000

15240

6859

203 / 448

61

0.73 / 2.6

0.73 / 2.6

7.0

M4AC050C

50000

14654

5955

196 / 432

60

0.70 / 2.5

0.70 / 2.5

6.8

380-415 / 3 / 50

1410 / 55.5

1160 / 45.7

460 / 18.1

40 / 1.41

M4AC020C M4AC025C M4AC030C M4AC040C

Btu/h 21000 23000 27000 40000

W 6154 6740 7912 11723

W 2617 2949 3679 4910

V/Ph/Hz

HEIGHT mm/in

WIDTH mm/in

DEPTH mm/in

kg/lb 116 / 256 123 / 271 128 / 282 195 / 430

dBA 57 57 58 60

l/s/m3/hr 0.29 / 1.0 0.32 / 1.2 0.38 / 1.4 0.56 / 2.0

MAX. WATER OPER. PRESSURE kPa/psi

l/s/m3/hr 0.29 / 1.0 0.32 / 1.2 0.38 / 1.4 0.56 / 2.0

INSTALLATION PIPE CONNECITON mm/in

m 7.3 9.9 8.9 9.2

L/ft3

800 / 31.5

1160 / 45.7

460 / 18.1

25.4 / 1

0 - 100%

CAPACITY/VOLUME

CAST IRON / STAINLESS STEEL

22 / 0.78

220-240 / 1 / 50

CAPILLARY TUBE

1000 / 145

R407C

MATERIAL

HEAD

WATER FLOW RATE

COMPRESSOR

STAGE OF CAPACITY CONTROL (Btu/h)

TANK

EVAPORATOR

NOMINAL WATER FLOW

PIPING

HYDRAULIC KIT

PUMP

MODEL

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

UNIT DIMENSION

CONTROL

POWER SOURCE

REFRIGERANT TYPE

UNIT WEIGHT

SOUND PRESSURE LEVEL

Notes:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 12ºC / 7ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35ºC AIR AMBIENT TEMPERATURE.b) HEATING - 40ºC / 45ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 7ºC AIR AMBIENT TEMPERATURE.

4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND1m BELOW THE UNIT.

M4AC020CR - M4AC060CR (Heatpump, R407C)

CAST IRON / STAINLESS STEEL

M4AC060CR

51000

14947

60000

17584

6507

6268

203 / 448

61

0.71 / 2.6

0.84 / 3.0

0.71 / 2.6

0.84 / 3.0

7.5

3.5

M4AC050CR

46000

13481

51000

14947

5446

5647

196 / 432

60

0.64 / 2.3

0.71 / 2.6

0.64 / 2.3

0.71 / 2.6

8.2

6.4

460 / 18.1

1410 / 55.5

1160 / 45.7

40 / 1.41

380-415 / 3 / 50

M4AC020CR M4AC025CR M4AC030CR M4AC040CR

Btu/h 17000 22000 25000 40000

W 4982 6448 7327 11723

Btu/h 20000 25500 32500 45000

W 5861 7474 9525 13188

COOLING W 2597 3076 3804 4820

HEATING W 2685 2745 4004 4994

V/Ph/Hz

HEIGHT mm/in

WIDTH mm/in

DEPTH mm/in

kg/lb 116 / 256 123 / 271 128 / 282 195 / 430

dBA 57 57 58 60

COOLING l/s/m3/hr 0.24 / 0.9 0.31 / 1.1 0.35 / 1.3 0.56 / 2.0

HEATING l/s/m3/hr 0.28 / 1.0 0.36 / 1.3 0.46 / 1.7 0.63 / 2.3

MAX. WATER OPER. PRESSURE kPa / psi

COOLING l/s/m3/hr

l/s/m3/hr

0.25 / 0.9 0.32 / 1.2 0.35 / 1.3 0.56 / 2.0

HEATING 0.31 / 1.1 0.35 / 1.3 0.46 / 1.7 0.63 / 2.3

INSTALLATION PIPE CONNECITON mm/in

COOLING m 8.7 10.1 9.4 9.2

HEATING m 7.7 9.3 7.6 7.5

L/ft3

800 / 31.5

1160 / 45.7

460 / 18.1

R407C

HEAD

WATER FLOW RATE

25.4 / 1

1000 / 145

0 - 100%

MATERIAL

CAPACITY/VOLUME 22 / 0.78

CAST IRON / STAINLESS STEEL CAST IRON / STAINLESS STEEL

220-240 / 1 / 50

CAPILLARY TUBE

MODEL

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER

REFRIGERANT TYPE

CONTROL

UNIT DIMENSION

PIPING

HYDRAULIC KIT

PUMP

COMPRESSOR

STAGE OF CAPACITY CONTROL (Btu/h)

TANK

POWER SOURCE

UNIT WEIGHT

SOUND PRESSURE LEVEL

EVAPORATOR

NOMINAL WATER FLOW

Page 28: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

S3

Mini Chiller Specifications

MAC080C - MAC150C (Cooling Only, R22)

MAC150C

138000

40445

13779

540 / 1190

69

2.00 / 7.2

2.00 / 7.2

23.0

HEIGHT

WIDTH

DEPTH

MAX. WATER OPER. PRESSURE

INSTALLATION PIPE CONNECITON

WATER FLOW RATE

UNIT WEIGHT

SOUND PRESSURE LEVEL

MODEL

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

UNIT DIMENSION

CONTROL

POWER SOURCE

REFRIGERANT TYPE

TANKMATERIAL

CAPACITY/VOLUME

1150 / 45.3

HYDRAULIC KIT

PUMP

EVAPORATOR

NOMINAL WATER FLOW

COMPRESSOR

STAGE OF CAPACITY CONTROL (Btu/h)

PIPINGHEAD

1800 / 70.9

MAC120C

116000

33998

11005

460 / 1014

67

1.67 / 6.0

1.67 / 6.0

25.0

NA

0 - 50 - 100%

380-415 / 3 / 50

TXV

1245 / 49.0

NA

42 / 1 1/4"

1000 / 145

R22

MAC100C

93000

27257

10175

350 / 772

66

1.31 / 4.7

1.31 / 4.7

23.5

900 / 35.4

1500 / 59.1

MAC080C

78000

22860

8667

340 / 750

65

1.08 / 3.9

1.08 / 3.9

26.0

Btu/h

W

W

V/Ph/Hz

mm/in

mm/in

mm/in

kg/lb

dBA

l/s/m3/hr

kPa/psi

l/s/m3/hr

mm/in

m

L/ft3

MAC080CR - MAC150CR (Heatpump, R22)

Notes:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 12ºC / 7ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35ºC AIR AMBIENT TEMPERATURE.b) HEATING - 40ºC / 45ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 7ºC AIR AMBIENT TEMPERATURE.

4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND1m BELOW THE UNIT.

MAC150CR

138000

40445

132000

38686

13881

14572

560 / 1235

69

2.00 / 7.2

2.10 / 7.6

2.00 / 7.2

2.10 / 7.6

23.0

22.5

COOLING

HEATING

HEIGHT

WIDTH

DEPTH

COOLING

HEATING

MAX. WATER OPER. PRESSURE

COOLING

HEATING

INSTALLATION PIPE CONNECITON

COOLING

HEATING

EVAPORATOR

NOMINAL WATER FLOW

UNIT DIMENSION

UNIT WEIGHT

SOUND PRESSURE LEVEL

NOMINAL TOTAL INPUT POWER

REFRIGERANT TYPE

COMPRESSOR

STAGE OF CAPACITY CONTROL (Btu/h)

TANKMATERIAL

CAPACITY/VOLUME

PIPINGHEAD

WATER FLOW RATE

HYDRAULIC KIT

PUMP

CONTROL

POWER SOURCE

MODEL

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

1150 / 45.3

1800 / 70.9

MAC120CR

113000

33118

120000

35169

11714

11948

480 / 1058

67

1.67 / 6.0

1.79 / 6.4

1.67 / 6.0

1.79 / 6.4

25.0

24.5

NA

0 - 50 - 100%

NA

1000 / 145

42 / 1 1/4"

CAPILLARY TUBE

1245 / 49.0

380-415 / 3 / 50

R22

MAC100CR

94000

27549

110000

32239

11255

10759

360 / 794

66

1.31 / 4.7

1.37 / 4.9

1.31 / 4.7

1.37 / 4.9

23.5

22.5

1500 / 59.1

900 / 35.4

MAC080CR

77000

22567

90000

26376

9577

9329

350 / 772

65

1.08 / 3.9

1.14 / 4.1

1.08 / 3.9

1.14 / 4.1

26.0

25.0

Btu/h

W

Btu/h

W

W

W

V/Ph/Hz

mm/in

mm/in

mm/in

kg/lb

dBA

l/s/m

l/s/m

kPa/psi

l/s/m3/hr

l/s/m3/hr

mm/in

m

m

L/ft3

Page 29: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

S4

Mini Chiller Specifications

M4AC080C - M4AC150C (Cooling Only, R407C)

Notes:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 12ºC / 7ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35ºC AIR AMBIENT TEMPERATURE. b) HEATING - 40ºC / 45ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 7ºC AIR AMBIENT TEMPERATURE.4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.

M4AC080CR - M4AC150CR (Heatpump, R407C)

M4AC150CR

Btu/h 130000

W 38101

Btu/h 144000

W 42204

COOLING W 15151

HEATING W 15824

V/Ph/Hz

HEIGHT mm/in

WIDTH mm/in

DEPTH mm/in

kg/lb 540 / 1190

dBA 69

COOLING l/s/m3/hr 2.00 / 7.2

HEATING l/s/m3/hr 2.10 / 7.6

MAX. WATER OPER. PRESSURE kPa/psi

COOLING l/s/m3/hr 2.00 / 7.2

HEATING l/s/m3/hr 2.10 / 7.6

INSTALLATION PIPE CONNECITON mm/in

COOLING m 23.0

HEATING m 22.5

L/ft3

CONTROL

POWER SOURCE

MODEL

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

PIPINGHEAD

WATER FLOW RATE

HYDRAULIC KIT

PUMP

COMPRESSOR

STAGE OF CAPACITY CONTROL (Btu/h)

TANKMATERIAL

CAPACITY/VOLUME

EVAPORATOR

NOMINAL WATER FLOW

UNIT DIMENSION

UNIT WEIGHT

SOUND PRESSURE LEVEL

NOMINAL TOTAL INPUT POWER

REFRIGERANT TYPE

1150 / 45.3

1800 / 70.9

M4AC120CR

110000

32239

118000

34583

12273

12386

460 / 1014

67

1.67 / 6.0

1.79 / 6.4

1.67 / 6.0

1.79 / 6.4

25.0

24.5

380-415 / 3 / 50

R407C

TXV

1245 / 49.0

1000 / 145

42 / 1 1/4"

NA

0 - 50 - 100%

NA

M4AC100CR

88000

25791

98000

28722

11028

11134

350 / 772

66

1.31 / 4.7

1.37 / 4.9

1.31 / 4.7

1.37 / 4.9

23.5

22.5

1500 / 59.1

900 / 35.4

M4AC080CR

74000

21688

90000

26377

9946

9975

340 / 750

65

1.08 / 3.9

1.14 / 4.1

1.08 / 3.9

1.14 / 4.1

26.0

25.0

M4AC150C

Btu/h 13700

W 40152

W 14531

V/Ph/Hz

HEIGHT mm/in

WIDTH mm/in

DEPTH mm/in

kg/lb 540 / 1190

dBA 69

l/s/m3/hr 2.00 / 7.2

MAX. WATER OPER. PRESSURE kPa/psi

l/s/m3/hr 2.00 / 7.2

INSTALLATION PIPE CONNECITON mm/in

m 23.0

L/ft3

EVAPORATOR

NOMINAL WATER FLOW

COMPRESSOR

STAGE OF CAPACITY CONTROL (Btu/h)

PIPINGHEAD

HYDRAULIC KIT

PUMP

TANKMATERIAL

CAPACITY/VOLUME

WATER FLOW RATE

UNIT WEIGHT

SOUND PRESSURE LEVEL

MODEL

NOMINAL COOLING CAPACITY

NOMINAL TOTAL INPUT POWER

UNIT DIMENSION

CONTROL

POWER SOURCE

REFRIGERANT TYPE

1800 / 70.9

1150 / 45.3

M4AC120C

115000

33705

11805

460 / 1014

67

1.67 / 6.0

1.67 / 6.0

25.0

380-415 / 3 / 50

TXV

1245 / 49.0

NA

42 / 1 1/4"

1000 / 145

R407C

NA

0 - 50 - 100%

M4AC100C

88000

25791

10771

350 / 772

66

1.31 / 4.7

1.31 / 4.7

23.5

1500 / 59.1

900 / 35.4

M4AC080C

74000

21688

9463

340 / 750

65

1.08 / 3.9

1.08 / 3.9

26.0

Page 30: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

M5ACV030CR - M5ACV135CR (Inverter Heatpump, R410A)

S5

Mini Chiller Specifications

M5AC020CR - M5AC055CR (Heatpump, R410A)

Notes:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 12ºC / 7ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35ºC AIR AMBIENT TEMPERATURE.b) HEATING - 40ºC / 45ºC ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 7ºC AIR AMBIENT TEMPERATURE.

4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND1m BELOW THE UNIT.

COOLING

HEATING

HEIGHT

WIDTH

DEPTH

COOLING

HEATING

MAX. WATER OPER. PRESSURE

COOLING

HEATING

INSTALLATION PIPE CONNECITON

COOLING

HEATING

MATERIAL

CAPACITY/VOLUME

HEAD

WATER FLOW RATE

M5ACV210CR

200000

58617

210000

61548

22300

21800

1786 / 70.31

2093 / 82.4

1192 / 46.9

682

85

2.67 (9.8)

2.86 (10.5)

2.7 (9.6)

2.9 (10.3)

38.0 / 1.5

25

25

0 - 210000

M5ACV135CR

131500

38540

141500

41470

15750

16250

1260 / 49.6

1800 / 70.9

1150 / 45.3

560 / 1235

67

1.8 ( 6.6 )

2.0 ( 7.1 )

1.8 ( 6.6 )

2.0 ( 7.1 )

16.5

14.5

0 - 149000

EXV / CAPILLARY TUBE

M5ACV100CR

95000

27800

100000

29300

12000

11400

1260 / 49.6

1500 / 59.1

900 / 35.4

360 / 794

63

1.3 ( 4.8 )

1.4 ( 5.0 )

1.3 ( 4.8 )

1.4 ( 5.0 )

17.3

15.7

0 - 122000

380-415 / 3 / 50

R410A

1000 / 145

NA

NA

M5ACV075CR

70000

20515

75000

21980

9050

7900

1460 / 57.5

1150 / 45.3

550 / 21.7

200 / 440

65

0.9 ( 3.4 )

1.0 ( 3.7 )

0.9 ( 3.4 )

1.0 ( 3.7 )

22.3

21.3

0 - 75000

25.4 / 1

M5ACV055CR

50000

14654

55000

16119

7600

6100

1410 / 55.5

1010 / 39.8

460 / 18.1

195 / 430

62

0.7 ( 2.5 )

0.8 ( 2.7 )

0.7 ( 2.5 )

0.8 ( 2.7 )

12.7

11.5

0 - 55000

ELECTRONIC EXPANSION VALVE (EXV)

M5ACV030CR

27000

7913

33000

9663

5279

4418

220-240 / 1 / 50

790 / 31.1

1010 / 39.8

460 / 18.1

128 / 282

59

0.3 ( 1.3 )

0.4 ( 1.5 )

0.3 ( 1.3 )

0.4 ( 1.5 )

7.7

7.0

0 - 28700

Btu/h

W

Btu/h

W

W

W

V/Ph/Hz

mm/in

mm/in

mm/in

kg/lb

dBA

l/s/m3/hr

l/s/m3/hr

kPa/psi

l/s/m3/hr

l/s/m3/hr

mm/in

m

m

L/ft3

MODEL

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER

REFRIGERANT TYPE

CONTROL

UNIT DIMENSION

POWER SOURCE

COMPRESSOR

STAGE OF CAPACITY CONTROL (Btu/h)

TANK

PIPING

HYDRAULIC KIT

UNIT WEIGHT

SOUND PRESSURE LEVEL

EVAPORATOR

NOMINAL WATER FLOW

COOLING

HEATING

HEIGHT

WIDTH

DEPTH

COOLING

HEATING

MAX. WATER OPER. PRESSURE

COOLING

HEATING

INSTALLATION PIPE CONNECITON

COOLING

HEATINGHEAD

MATERIAL

WATER FLOW RATE

CAPACITY/VOLUME

1410 / 55.5

1010 / 39.8

460 / 18.1

M5AC055CR

50000

14641

55000

16105

5890

5990

173 / 381

60

0.72 / 2.6

0.72 / 2.6

0.72 / 2.6

7.9

5.7

0 - 50 - 100%

M5AC050CR

47000

13763

51000

14934

5090

5130

167 / 368

60

0.64 / 2.3

0.64 / 2.3

0.64 / 2.3

7.9

6.4

220-240 / 1 / 50 or 380-415 / 3 / 50

NA

CAPILLARY TUBE & TXV

0 - 40 - 60 - 100%

NA

M5AC040CR

37500

10981

40800

11947

4330

4490

1410 / 55.5

1010 / 39.8

460 / 18.1

165 / 364

60

0.53 / 1.9

0.53 / 1.9

0.53 / 1.9

10.0

8.9

R410A

1000 / 145

25.4 / 1

M5AC030CR

26800

7848

32500

9517

3720

3630

790 / 31.1

1010 / 39.8

460 / 18.1

125 / 276

58

0.42 / 1.5

0.42 / 1.5

0.42 / 1.5

9.0

7.7

0 - 50 - 100%

M5AC025CR

21000

6150

25000

7330

2760

2790

165 / 364

57

0.28 / 1.00

0.35 / 1.25

0.28 / 1.00

0.35 / 1.25

10.1

9.3

220-240 / 1 / 50

CAST IRON / STAINLESS STEEL

CAPILLARY TUBE

800 / 31.5

1160 / 45.7

460 / 18.1

0 - 100%

22 / 0.78

M5AC020CR

17000

4980

21500

6300

2550

2590

125 / 276

57

0.23 / 0.84

0.32 / 1.16

0.23 / 0.84

0.32 / 1.16

8.7

7.7

Btu/h

W

Btu/h

W

W

W

V/Ph/Hz

mm/in

mm/in

mm/in

kg/lb

dBA

l/s/m3/hr

l/s/m3/hr

kPa/psi

l/s/m3/hr

l/s/m3/hr

mm/in

m

m

L/ft3

POWER SOURCE

PIPING

TANK

REFRIGERANT TYPE

MODEL

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER

CONTROL

UNIT DIMENSION

UNIT WEIGHT

SOUND PRESSURE LEVEL

EVAPORATOR

NOMINAL WATER FLOW

HYDRAULIC KIT

PUMP

STAGE OF CAPACITY CONTROL (Btu/h)

COMPRESSOR

Page 31: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

S6

Chilled Water Fan Coil Unit Specifications

MCK020AW - MCK050AW (Ceilling Cassette A Series)

HIGH

HEIGHT

WIDTH

DEPTH

MODEL

NOMINAL TOTAL COOLING CAPACITY

NOMINAL SENSIBLE COOLING CAPACITY

NOMINAL TOTAL HEATING CAPACITY (ENTERING

WATER TEMP. = 50°C)

NOMINAL AIR FLOW

UNIT DIMENSION - ( ) WITH PANEL

UNIT WEIGHT ( UNIT + PANEL )

CONNECTION

SOUND PRESSURE LEVEL ( H/M/L )

NOMINAL WATER FLOW RATE

HEAD LOSS (COOLING)

HEAD LOSS (HEATING) : 50°C

MCK050AW

36500

10800

26300

7700

44000

12900

511 / 1083

( 40+4 ) / ( 88+8.8 )

53 / 52 / 50

8.20

31.00

69.3 / 10.05

64.1 / 9.29

MCK040AW

33500

9950

24200

7100

40500

12000

483 / 1024

( 38+4 ) / (83.6+8.8 )

51 / 48 / 46

7.50

28.35

52.2 / 7.57

45.2 / 6.55

MCK030AW

30000

8800

21800

6400

37500

11000

433 / 918

( 35+4 ) / ( 77+8.8 )

49 / 45 / 43

6.70

25.33

41.6 / 6.03

35.3 / 5.12

335 / 13.2 ( 363 / 14.3 )

820 / 32.3 ( 930 / 36.6 )

821 / 32.3 ( 930 / 36.6 )

3/4" BSP FEMALE UNION

MCK025AW

25500

7500

18400

5400

32000

9500

383 / 812

( 32+4 ) / ( 70.4+0.44 )

45 / 42 / 40

5.70

21.55

30.8 / 4.47

26.8 / 3.89

MCK020AW

22500

6620

16700

4900

28500

8400

364 / 771

( 31+4 ) / ( 68.2+8.8 )

42 / 39 / 37

5.00

18.90

24.8 / 3.6

21.4 / 3.1

Btu/h

W

Btu/h

W

Btu/h

W

l/s / CFM

mm/in

mm/in

mm/in

kg/lb

dBA

USGPM

LITRES/M

kPa / psi

kPa / psi

Notes:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - ENTERING AIR TEMP. : 27°C (80.6°F) DB / 19°C (66.2°F) WB, ENTERING WATER TEMP. : 7°C (44.6°F), LEAVING WATER TEMP. : 12°C (53.6°F)b) HEATING - ENTERING AIR TEMP.: 20°C (68°F) DB, ENTERING WATER TEMP. : 70°C (158°F), LEAVING WATER TEMP. : 65°C (149°F)

4) SOUND PRESSURE LEVEL IS MEASURE IN ANECHOIC CHAMBER, AND ACCORDING TO JIS C 9612 STANDARD. MCK020/025AW/AWH : POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW THE FACIA. MCK030/040/050AW/AWH : 1.5m BELOW THE FACIA (JIS B 8615).

MCK020AWH - MCK050AWH (4 Pipies Ceilling Cassette)

HIGH

MEDIUM

LOW

HEIGHT

WIDTH

DEPTH

MODEL

NOMINAL TOTAL COOLING CAPACITY

NOMINAL SENSIBLE COOLING CAPACITY

NOMINAL TOTAL HEATING CAPACITY (ENTERING

WATER TEMP. = 50°C)

NOMINAL AIR FLOW

UNIT DIMENSION - ( ) WITH PANEL

Cooling

Add.Heat

Exch

UNIT WEIGHT ( UNIT + PANEL )

SOUND PRESSURE LEVEL ( H/M/L )

HEAD LOSS (COOLING)

CONNECTION

HEAD LOSS (HEATING) : 50°C

NOMINAL WATER FLOW RATE

MCK050AWH

17600

5160

15500

4540

47000

13770

491 / 1040

448 / 950

411 / 870

( 40+4 ) / ( 88+8.8 )

53 / 52 / 50

3.90

14.74

5.20

19.67

5.96 / 0.86

8.8 / 1.28

MCK040AWH

17100

5010

15000

4400

46000

13480

467 / 990

406 / 860

359 / 760

( 38+4 ) / (83.6+8.8 )

51 / 48 / 46

3.80

14.36

5.11

19.3

5.7 / 0.83

8.6 / 1.23

MCK030AWH

15800

4630

13900

4070

42700

12510

415 / 880

349 / 740

321 / 680

( 35+4 ) / ( 77+8.8 )

49 / 45 / 43

3.50

13.23

4.76

18

4.94 / 0.72

7.2 / 1.04

335 / 13.2 ( 363 / 14.3 )

820 / 32.3 ( 930 / 36.6 )

821 / 32.3 ( 930 / 36.6 )

3/4" BSP FEMALE UNION

MCK025AWH

13500

3960

12000

3520

37500

10990

368 / 780

312 / 660

283 / 600

( 32+4 ) / ( 70.4+0.44 )

45 / 42 / 40

3.00

11.34

4.19

15.83

3.78 / 0.55

5.5 / 0.8

MCK020AWH

13000

3810

11600

3400

36000

10550

349 / 740

297 / 630

283 / 600

( 31+4 ) / ( 68.2+8.8 )

42 / 39 / 37

2.90

10.96

4.00

15.1

3.56 / 0.52

4.8 / 0.7

Btu/h

W

Btu/h

W

Btu/h

W

l/s / CFM

l/s / CFM

l/s / CFM

mm/in

mm/in

mm/in

kg/lb

dBA

USGPM

LITRES/M

USGPM

LITRES/M

kPa / psi

kPa / psi

Page 32: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

S7

HIGH

HEIGHT

WIDTH

DEPTH

CONNECTION

NOMINAL AIR FLOW

UNIT DIMENSION - ( ) WITH PANEL

UNIT WEIGHT ( UNIT + PANEL )

HEAD LOSS (COOLING)

HEAD LOSS (HEATING) : 50°C

SOUND PRESSURE LEVEL ( H/M/L )

NOMINAL WATER FLOW RATE

MODEL

NOMINAL TOTAL COOLING CAPACITY

NOMINAL SENSIBLE COOLING CAPACITY

NOMINAL TOTAL HEATING CAPACITY (ENTERING

WATER TEMP. = 50°C)

MCK025BW

18000

5270

13300

3900

21000

6150

226 / 480

( 31+3 ) / (68.2+6.6 )

43 / 41 / 37

4.00

15.20

10.3 / 1.50

15.9 / 2.30

MCK020BW

17000

4980

11330

3320

18000

5270

40 / 36 / 30

3.79

14.30

9.70 / 1.41

7.6 / 1.10

293 / 11.5 ( 345 / 13.6 )

650 / 25.6 ( 727 / 28.6 )

650 / 25.6 ( 727 / 28.6 )

3/4" BSP FEMALE UNION

194 / 410

( 30+3 ) / ( 66+6.6)

MCK015BW

12500

3660

9250

2710

16000

4690

36 / 33 / 29

2.78

10.50

39.3 / 5.70

33 / 4.78

Btu/h

W

Btu/h

W

Btu/h

W

l/s / CFM

mm/in

mm/in

mm/in

kg/lb

dBA

USGPM

LITRES/M

kPa / psi

kPa / psi

Chilled Water Fan Coil Unit Specifications

MCK015BW - MCK025BW (Ceilling Cassette B Series)

HIGH

HEIGHT

WIDTH

DEPTH

HEAD LOSS (COOLING)

NOMINAL WATER FLOW RATE

CONNECTION

UNIT DIMENSION - ( ) WITH PANEL

MODEL

NOMINAL TOTAL COOLING CAPACITY

NOMINAL SENSIBLE COOLING CAPACITY

NOMINAL TOTAL HEATING CAPACITY (ENTERING

WATER TEMP. = 50°C)

HEAD LOSS (HEATING) : 50°C

UNIT WEIGHT ( UNIT + PANEL ) ( 23+2 ) / ( 50.6+4.4 )

SOUND PRESSURE LEVEL ( H/M/L )

NOMINAL AIR FLOW

MCK020CW

14500

4250

11100

3240

18500

5420

203 / 430

47 / 46 / 44

3.22

12.17

68.8 / 9.98

71.2 / 10.32

MCK015CW

14000

4100

10400

3060

17500

5120

44 / 42 / 41

3.10

11.83

68.6 / 9.95

70.5 / 10.22

250 / 9.8 ( 295 / 11.6 )

570 / 22.4 ( 640 / 25.2 )

3/4" BSP FEMALE UNION

570 / 22.4 ( 640 / 25.2 )

184 / 390

MCK010CW

8000

2340

6700

1970

10900

3200

( 22+2 ) / (48.5+4.4)

44 / 43 / 42

1.76

6.67

67.3 / 9.76

61.9 / 8.98

Btu/h

W

Btu/h

W

Btu/h

W

l/s / CFM

mm/in

mm/in

mm/in

kg/lb

dBA

USGPM

LITRES/M

kPa / psi

kPa / psi

MCK010CW - MCK020CW (Ceilling Cassette C Series)

Notes:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - ENTERING AIR TEMP. : 27°C (80.6°F) DB / 19°C (66.2°F) WB, ENTERING WATER TEMP. : 7°C (44.6°F), LEAVING WATER TEMP. : 12°C (53.6°F)b) HEATING - ENTERING AIR TEMP.: 20°C (68°F) DB, ENTERING WATER TEMP. : 70°C (158°F), LEAVING WATER TEMP. : 65°C (149°F)

4) SOUND PRESSURE LEVEL ARE MEASURED IN ANECHOIC TEST ROOM & ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW THE FACIA.

Page 33: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

S8

3/4" BSP FEMALE ADAPTOR

MCM007CBW MCM010CBW MCM015CBW MCM020DW

6500 8600 10500 17700

1910 2500 3080 5190

5000 6660 8570 13650

1460 1950 2510 4000

7800 10600 14300 22000

2280 3100 4190 6450

95 / 200 142/ 300 190 / 400 264 / 660

214 / 8.4

1214 / 47.8

1174 / 46.2 670 / 26.4

35 / 77.2 43 / 94.8

45 / 42 / 37 46 / 43 / 38 47 / 44 / 39 50 / 47 / 40

1.45 1.89 2.33 3.92

5.50 7.17 8.83 14.83

9.30 / 1.35 15.4 / 2.23 4.5 / 0.65 45.6 / 6.61

7.0 / 1.01 12.7 / 1.84 3.6 / 0.52 39.2 / 5.68

235 / 9.3

666 / 26.2

33 / 72.8

824 / 32.4

Chilled Water Fan Coil Unit Specifications

MCM007CBW - MCM020DW (Ceilling Convertible)

Btu/h

W

Btu/h

W

Btu/h

W

HIGH l/s/CFM

HEIGHT mm/in

WIDTH mm/in

DEPTH mm/in

kg/lb

dBA

USGPM

LITRES/M

kPa/psi

kPa/psi

NOMINAL AIR FLOW

UNIT DIMENSION

UNIT WEIGHT

MODEL

NOMINAL TOTAL COOLING CAPACITY

NOMINAL SENSIBLE COOLING CAPACITY

NOMINAL TOTAL HEATING CAPACITY (ENTERINGWATER TEMP. = 70ºC)

CONNECTION

SOUND PRESSURE LEVEL ( H/M/L )

NOMINAL WATER FLOW RATE

HEAD LOSS (COOLING)

HEAD LOSS (HEATING) : 70ºC

Notes:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :a) COOLING - ENTERING AIR TEMP. : 27ºC (80.6ºF) DB / 19ºC (66.2ºF) WB, ENTERING WATER TEMP. : 7ºC (44.6ºF), LEAVING WATER TEMP. : 12ºC (53.6ºF)b) HEATING - ENTERING AIR TEMP.: 20ºC (68ºF) DB, ENTERING WATER TEMP. : 70ºC (158ºF), LEAVING WATER TEMP. : 65ºC (149ºF)c) MCM025DW-MCM050DW: HEATING - ENTERING AIR TEMP.: 20ºC (68ºF) DB, ENTERING WATER TEMP. : 60ºC (140ºF), LEAVING WATER TEMP. : 55ºC (131ºF)4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER ACCORDING TO JIS C 9612 STANDARD. MCM020/025DW : POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT

AND 0.8m BELOW THE UNIT. MCM030/040/050DW : 1 m IN FRONT OF THE UNIT AND 1m BELOW THE AIR DISCHARGE OPENING. (JIS B 8615) MCE007-015CBW: 1m IN FRONT AND 0.8m BELOW THE VERTICAL CENTRE LINE OF THE UNIT.

MCM025DW - MCM050DW (Ceilling Convertible)

MCM025DW MCM030DW MCM040DW MCM050DW

Btu/h 20800 24600 31200 45000

W 6100 4210 9140 13190

Btu/h 15000 17700 25600 31400

W 4400 5190 7500 9200

Btu/h 25900 28000 42300 51500

W 7590 8210 12400 15100

HIGH l/s/CFM 297 / 630 329 / 697 449 / 949 500 / 1058

HEIGHT mm/in 214 / 8.4

WIDTH mm/in

DEPTH mm/in

kg/lb 43 / 94.8 45 / 99.2

dBA 54 / 53 / 50 51 / 50 / 48 54 / 53 / 52 54 / 53 / 52

USGPM 4.63 5.46 6.91 10.00

LITRES/M 17.50 20.67 26.17 37.83

kPa/psi 55.7 / 8.07 49.4 / 7.16 124.0 / 3.48 37.7 / 5.46

kPa/psi 48.1 / 6.97 43.0 / 6.23 21.5 / 3.11 31.6 / 4.58

249 / 9.8

1214 / 47.8 1714 / 67.5

3/4" BSP FEMALE ADAPTOR

70 / 154.3

670 / 26.4

CONNECTION

SOUND PRESSURE LEVEL ( H/M/L )

NOMINAL WATER FLOW RATE

HEAD LOSS (COOLING)

HEAD LOSS (HEATING) : 60ºC

NOMINAL SENSIBLE COOLING CAPACITY

NOMINAL TOTAL HEATING CAPACITY (ENTERINGWATER TEMP. = 60ºC)

NOMINAL AIR FLOW

UNIT WEIGHT

MODEL

UNIT DIMENSION

NOMINAL TOTAL COOLING CAPACITY

Page 34: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

S9

Chilled Water Fan Coil Unit Specifications

MCC010CW - MCC028CW (Ceiling Concealed)

SUPER HIGH

HIGH

MEDIUM

LOW

HEIGHT

WIDTH

DEPTH

NOMINAL AIR FLOW

EXTERNAL STATIC ( H/M/L )

UNIT DIMENSION

UNIT WEIGHT

SOUND PRESSURE LEVEL ( H/M/L )

NOMINAL WATER FLOW RATE

HEAD LOSS (COOLING)

MODEL

NOMINAL TOTAL COOLING CAPACITY

NOMINAL SENSIBLE COOLING CAPACITY

NOMINAL TOTAL HEATING CAPACITY (ENTERINGWATER TEMP. = 60ºC)

CONNECTION

HEAD LOSS (HEATING) : 60ºC

MCC028CW

26000

7620

19500

5715

55000

16120

401 / 850

382 / 810

363 / 770

335 / 710

10 / 8 / 7 / 6

290 / 11.4

942 / 37.1

600 / 23.6

38 / 83.8

44 / 41 / 38 / 34

5.70

21.58

14.69 / 2.13

11.38 / 1.65

MCC025CW

22500

6594

17900

5246

48000

14068

NA

345 / 730

340 / 720

274 / 580

5 / 4 / 3

261 / 10.3

1200 / 47.2

411 / 16.2

25 / 55.1

40 / 39 / 36

4.70

17.79

24.12 / 3.50

18.96 / 2.75

MCC020CW

18000

5275

13600

3986

38000

11137

NA

330 / 700

321 / 680

293 / 620

5 / 4 / 3

263 / 10.3

1065 / 41.9

413 / 16.2

22 / 48.5

38 / 36 / 34

4.20

15.90

18.28 / 2.65

14.20 / 2.06

3/4" BSP FEMALE ADAPTOR

MCC015CW

15000

4396

10000

2931

25500

7474

NA

241 / 510

208 / 440

170 / 360

5 / 4 / 3

262 / 10.3

905 / 35.6

412 / 16.2

21 / 46.3

37 / 34 / 29

2.58

9.77

13.97 / 2.03

10.76 / 1.56

MCC010CW

9900

2902

7000

2052

19000

5569

NA

142 / 300

123 / 260

104 / 220

5 / 4 / 3

261 / 10.3

765 / 30.1

411 / 16.2

17 / 37.5

33 / 30 / 26

2.00

7.57

8.83 / 1.28

6.69 / 0.97

Btu/h

W

Btu/h

W

Btu/h

W

l/s/CFM

l/s/CFM

l/s/CFM

l/s/CFM

mmAq

mm/in

mm/in

mm/in

kg/lb

dBA

USGPM

LITRES/M

kPa/psi

kPa/psi

Notes:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - ENTERING AIR TEMP. : 27ºC (80.6ºF) DB / 19ºC (66.2ºF) WB, ENTERING WATER TEMP. : 7ºC (44.6ºF), LEAVING WATER TEMP. : 12ºC (53.6ºF)b) HEATING - ENTERING AIR TEMP.: 20°C (68°F) DB, ENTERING WATER TEMP. : 60°C (140°F), LEAVING WATER TEMP. : 55°C (131°F)

4) SOUND PRESSURE LEVEL ARE ACCORDING TO GB STD - GB/D17758. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW THE CENTRE OF THE UNIT. TESTED WITH 2m LENGTH DUCT AT THE AIR DISCHARGE OUTLET ANS AIR RETURN INLET.

MCC030CW - MCC060CW (Ceiling Concealed)

SUPER HIGH

HIGH

MEDIUM

LOW

HEIGHT

WIDTH

DEPTH

HEAD LOSS (COOLING)

UNIT DIMENSION

NOMINAL WATER FLOW RATE

7/8" BSP FEMALE ADAPTOR

MODEL

NOMINAL TOTAL COOLING CAPACITY

NOMINAL SENSIBLE COOLING CAPACITY

NOMINAL TOTAL HEATING CAPACITY (ENTERING WATER TEMP. = 60ºC)

EXTERNAL STATIC ( SH/H/M/L )

UNIT WEIGHT

SOUND PRESSURE LEVEL ( SH/H/M/L )

NOMINAL AIR FLOW

CONNECTION

HEAD LOSS (HEATING) : 60ºC

MCC060CW

54000

15826

39900

11694

110000

32239

779 / 1650

722 / 1530

675 / 1430

609 / 1290

18 / 16 / 14 / 10

379 / 14.9

1499 / 59.0

542 / 21.3

62 / 136.7

55 / 53 / 50 / 47

10.80

40.88

7.01 / 1.02

5.38 / 0.78

MCC050CW

47000

13775

34700

10170

95000

27843

750 / 1590

651 / 1380

604 / 1280

571 / 1210

18 / 16 / 14 / 11

378 / 14.9

1299 / 51.1

541 / 21.3

54 / 119.0

53 / 52 / 50 / 47

10.00

37.85

37.08 / 5.38

29.65 / 4.30

MCC040CW

38000

11137

34000

9965

75000

21981

519 / 1100

500 / 1060

467 / 990

425 / 900

21/ 18 / 13 / 9

378 / 14.9

1045 / 41.1

541 / 21.3

42 / 92.6

51 / 49 / 45 / 41

7.40

28.01

18.86 / 2.74

14.69 / 2.13

MCC038CW

35000

10258

27600

8089

65000

19050

727 / 1540

694 / 1470

670 / 1420

637 / 1350

14 / 12 / 11 / 9

310 / 12.2

1247 / 49.1

638 / 25.1

41 / 90.4

55 / 51 / 48 / 45

9.60

36.34

44.24 / 6.42

35.78 / 5.19

3/4" BSP FEMALE ADAPTOR

MCC030CW

28000

8206

21800

6389

60000

17585

425 / 900

392 / 830

359 / 760

335 / 710

21 / 17 / 13 / 9

378 / 14.9

929 / 36.6

541 / 21.3

39 / 86.0

49 / 46 / 42 / 38

6.20

23.47

12.82 / 1.89

9.86 / 1.43

Btu/h

W

Btu/h

W

Btu/h

W

l/s/CFM

l/s/CFM

l/s/CFM

l/s/CFM

mmAq

mm/in

mm/in

mm/in

kg/lb

dBA

USGPM

LITRES/M

kPa/psi

kPa/psi

Page 35: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

S10

Chilled Water Fan Coil Unit Specifications

MCW200C - MCW1200C (Ceilling Concealed)

SUPER HIGH

HIGH

MEDIUM

LOW

HEIGHT

WIDTH

DEPTH

CONNECTION

EXTERNAL STATIC ( H/M/L )

UNIT DIMENSION

SOUND PRESSURE LEVEL ( H/M/L ) AT 60Pa

NOMINAL AIR FLOW

HEAD LOSS (HEATING) : 60ºC

UNIT WEIGHT

HEAD LOSS (COOLING)

NOMINAL WATER FLOW RATE

MODEL

NOMINAL TOTAL COOLING CAPACITY

NOMINAL SENSIBLE COOLING CAPACITY

NOMINAL TOTAL HEATING CAPACITY(ENTERING WATER TEMP. = 60ºC)

MCW1200C

40650

11914

27340

8013

69810

20460

NA

575 / 1218

489 / 1036

419 / 888

251 / 9.9

1824 / 71.8

490 / 19.3

46

52.4 / 50.6 / 47.4

10.04

38.00

32.7 / 4.74

32.7 / 4.74

MCW1000C

31360

9191

21290

6240

53970

15818

NA

455 / 965

378 / 800

305 / 647

251 / 9.9

1564 / 61.6

490 / 19.3

44

53.1 / 52.0 / 51.1

7.66

29.00

21 / 3.05

21 / 3.05

MCW800C

27880

8171

18470

5413

48510

14217

NA

403 / 853

328 / 695

256 / 542

251 / 9.9

1464 / 57.6

490 / 19.3

41

53.1 / 51.5 / 49.7

6.34

24.00

18.4 / 2.67

18.4 / 2.67

MCW600C

22260

6524

15020

4402

38640

11325

NA

295 / 624

236 / 500

197 / 418

251 / 9.9

1214 / 47.8

490 / 19.3

30

49.0 / 47.2 / 43.3

4.76

18.00

38.2 / 5.54

38.2 / 5.54

Up to 8.13 mmAq

3/4" BSP FEMALE ADAPTOR

MCW400C

14450

4235

9740

2855

25740

7544

NA

214 / 453

144 / 306

109 / 230

251 / 9.9

1014 / 39.9

490 / 19.3

26

48.7 / 46.3 / 46.4

3.43

13.00

21.6 / 3.13

21.6 / 3.13

MCW300C

11460

3359

7850

2301

19510

5718

NA

153 / 324

129 / 274

97 / 206

251 / 9.9

884 / 34.8

490 / 19.3

22

48.3 / 44.7 / 37.8

2.64

10.00

12 / 1.74

12 / 1.74

MCW200C

7710

2260

5120

1501

13440

3939

NA

114 / 241

94 / 200

64 / 135

251 / 9.9

714 / 28.1

490 / 19.3

19

40.1 / 37.2 / 34.9

1.85

7.00

14.6 / 2.12

14.6 / 2.12

Btu/h

W

Btu/h

W

Btu/h

W

l/s/CFM

l/s/CFM

l/s/CFM

l/s/CFM

mmAq

mm/in

mm/in

mm/in

kg/lb

dBA

USGPM

LITRES/M

kPa/psi

kPa/psi

Notes:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - ENTERING AIR TEMP. : 27ºC (80.6ºF) DB / 19.5ºC (67.1ºF) WB, ENTERING WATER TEMP. : 7ºC (44.6ºF), LEAVING WATER TEMP. : 12ºC (53.6ºF)b) HEATING - ENTERING AIR TEMP.: 21ºC (69.8ºF) DB, ENTERING WATER TEMP. : 60ºC (140ºF), LEAVING WATER TEMP. : 55ºC (131ºF)

3) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW THE FACIA.

MCW200H - MCW1200H (Ceilling Concealed)

SUPER HIGH

HIGH

MEDIUM

LOW

HEIGHT

WIDTH

DEPTH

NOMINAL AIR FLOW

UNIT DIMENSION

MODEL

NOMINAL TOTAL COOLING CAPACITY

NOMINAL TOTAL HEATING CAPACITY(ENTERING WATER TEMP. = 60ºC) - 1 ROW

NOMINAL WATER FLOW RATE - 3 ROWS

NOMINAL WATER FLOW RATE - 1 ROW

CONNECTION

NOMINAL SENSIBLE COOLING CAPACITY

NOMINAL TOTAL HEATING CAPACITY(ENTERING WATER TEMP. = 60ºC) - 3 ROWS

EXTERNAL STATIC ( SH/H/M/L )

UNIT WEIGHT

SOUND PRESSURE LEVEL ( H/M/L ) AT 60Pa

HEAD LOSS (COOLING) - 3 ROWS

HEAD LOSS (HEATING) : 60ºC - 3 ROWs

HEAD LOSS (COOLING) - 1 ROW

HEAD LOSS (HEATING) : 60ºC - 1 ROW

MCW1200H

34800

10200

26410

7740

64110

18790

29240

8570

NA

604 / 1280

519 / 1100

425 / 900

251 / 9.9

1824 / 71.8

490 / 19.3

49

52.4 / 50.6 / 47.4

8.45

32.00

3.72

14.10

45 / 6.53

45 / 6.53

20 / 2.9

20 / 2.9

MCW1000H

28320

8300

20130

5900

49300

14450

23920

7010

NA

472 / 1000

415 / 880

302 / 640

251 / 9.9

1564 / 61.6

490 / 19.3

47

53.1 / 52.0 / 51.1

6.87

26.00

3.20

12.10

26 / 3.77

26 / 3.77

18 / 2.61

18 / 2.61

MCW800H

26100

7650

18080

5300

43670

12800

17740

5200

NA

396 / 840

345 / 730

288 / 610

251 / 9.9

1464 / 57.6

490 / 19.3

44

53.1 / 51.5 / 49.7

6.13

23.20

2.38

9.00

33 / 4.79

33 / 4.79

21 / 3.05

21 / 3.05

MCW600H

20810

6100

14330

4200

33300

9760

15120

4430

NA

316 / 670

307 / 650

212 / 450

251 / 9.9

1214 / 47.8

490 / 19.3

32

49.0 / 47.2 / 43.3

4.76

18.00

2.11

8.00

47 / 6.82

47 / 6.82

17 / 2.47

17 / 2.47

3/4" BSP FEMALE ADAPTOR

Up to 8.13 mmAq

MCW400H

14330

4200

9900

2900

24670

7230

11430

3350

NA

212 / 450

189 / 400

165 / 350

251 / 9.9

1014 / 39.9

490 / 19.3

28

48.7 / 46.3 / 46.4

3.43

13.00

1.74

6.60

22 / 3.19

22 / 3.19

15 / 2.18

15 / 2.18

MCW300H

10240

3000

6960

2040

17200

5040

7850

2300

NA

165 / 350

142 / 300

94 / 200

251 / 9.9

884 / 34.8

490 / 19.3

24

48.3 / 44.7 / 37.8

2.51

9.50

1.22

4.60

13 / 1.89

13 / 1.89

8 / 1.16

8 / 1.16

MCW200H

7710

2260

5220

1530

12180

3570

4810

1410

NA

113 / 240

94 / 200

76 / 160

251 / 9.9

714 / 28.1

490 / 19.3

20

40.1 / 37.2 / 34.9

1.80

6.80

0.87

3.30

16 / 2.32

16 / 2.32

8 / 1.16

8 / 1.16

Btu/h

W

Btu/h

W

Btu/h

W

Btu/h

W

l/s/CFM

l/s/CFM

l/s/CFM

l/s/CFM

mmAq

mm/in

mm/in

mm/in

kg/lb

dBA

USGPM

LITRES/M

USGPM

LITRES/M

kPa/psi

kPa/psi

kPa/psi

kPa/psi

Page 36: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

S11

Chilled Water Fan Coil Unit Specifications

MWM007GW - MWM025GW (Wall Mount)

MODEL

HIGH

HEIGHT

WIDTH

DEPTH

NOMINAL TOTAL COOLING CAPACITY - 1

NOMINAL SENSIBLE COOLING CAPACITY

NOMINAL TOTAL HEATING CAPACITY(ENTERING WATER TEMP. = 50°C)

NOMINAL AIR FLOW

NOMINAL TOTAL COOLING CAPACITY - 1Ø <3Ø>

HEAD LOSS (COOLING)

HEAD LOSS (HEATING) : 50°C

CONNECTION

UNIT WEIGHT

SOUND PRESSURE LEVEL ( H/M/L )

NOMINAL SENSIBLE COOLING CAPACITY

NOMINAL TOTAL HEATING CAPACITY(ENTERING WATER TEMP. = 50°C)

NOMINAL WATER FLOW RATE

UNIT DIMENSION

NOMINAL WATER FLOW RATE

HEAD LOSS (COOLING)

HEAD LOSS (HEATING) : 50°C

MWM025GW

18000

5280

14800

4330

23000

6740

18000

5275

13680

4009

23000

6741

312 / 660

16 / 35.3

50 / 48 / 44

4.00

15.12

69.3 / 10.05

70.6 / 10.243.65

13.82

41.7 / 6.04

35.8 / 5.19

304 / 12.0

1062 / 41.8

222 / 8.7

MWM020GW

15500

4540

12500

3650

20500

6010

15500

4543

11780

3453

20500

6008

297 / 630

16 / 35.3

49 / 43 / 40

3.40

12.85

50.3 / 7.29

50.6 / 7.343.43

12.98

50.4 / 7.31

50.9 / 7.38

MWM015GW

11000

3220

8000

2350

14000

4100

11000

3224

8360

2450

14000

4103

163 / 345

42 / 36 / 29

2.40

9.07

69.3 / 10.05

60.6 / 8.792.42

9.16

67.8 / 9.83

61.8 / 8.95

12 / 26.5

899 / 35.4

198 / 7.8

260 / 10.2

MWM010GW

9500

2780

6900

2030

12800

3750

9500

2784

7220

2116

12800

3751

142 / 300

39 / 34 / 28

2.10

7.94

64.7 / 9.38

58.6 / 8.52.16

8.18

54.9 / 7.95

47.0 / 6.81

1/2" BSP FEMALE ADAPTOR

MWM007GW

8000

2340

5900

1740

10300

3020

130 / 275

260 / 10.2

799 / 31.5

198 / 7.8

10 / 22.1

40 / 35 / 29

1.80

6.80

48.3 / 7

42 / 6.09

NA

NA

Btu/h

W

Btu/h

W

Btu/h

W

Btu/h

W

Btu/h

W

Btu/h

W

USGPM

LITRES/M

kPa / psi

kPa / psi

USGPM

LITRES/M

kPa / psi

kPa / psi

l/s / CFM

mm/in

mm/in

mm/in

kg/lb

dBA

60Hz

50Hz

50Hz

60Hz

Notes:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - ENTERING AIR TEMP. : 27°C (80.6°F) DB / 19°C (66.2°F) WB, ENTERING WATER TEMP. : 7°C (44.6°F), LEAVING WATER TEMP. : 12°C (53.6°F)b) HEATING - ENTERING AIR TEMP.: 20°C (68°F) DB, ENTERING WATER TEMP. : 70°C (158°F), LEAVING WATER TEMP. : 65°C (149°F)

4) a) MDB: SOUND PRESSURE LEVEL ARE TESTED IN ANECHOIC CHAMBER AT 1.4m BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM) b) MWM:SOUND PRESSURE LEVEL ARE TESTED IN ANECHOIC CHAMBER AND ACCORDING TO JIS C 9612 STANDARD. MWMFW : POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT. MWM301W : 1m IN FRONT AND 1 m BELOW THE DISCHARGE OPENING OF THE UNIT (JIS B 8615)

MDB075BW - MDB0150BW (Ducted Blower)

HEIGHT

WIDTH

DEPTH

1 1/8" BRAZING

10

NOMINAL AIR FLOW

15

HEAD LOSS (HEATING) : 70°C

HEAD LOSS (COOLING)

UNIT DIMENSION

UNIT WEIGHT

NOMINAL WATER FLOW RATE

NOMINAL SENSIBLE COOLING CAPACITY

SOUND PRESSURE LEVEL

EXTERNAL STATIC

CONNECTION

NOMINAL TOTAL HEATING CAPACITY(ENTERING WATER TEMP. = 70°C)

NOMINAL TOTAL COOLING CAPACITY

MODEL MDB075BW

73000

21395

57200

16764

160000

46893

1128 / 2390

572 / 22.5

1502 / 59.1

761 / 30.0

96 / 211.6

56

16.30

61.70

20.13 / 2.92

15.89 / 2.30

MDB0100BW

95000

27843

71400

20926

200000

58617

1444 / 3060

572 / 22.5

1502 / 59.1

761 / 30.0

100 / 220.5

57

20.00

75.71

16.27 / 2.36

12.69 / 1.84

MDB0125BW

122500

35903

94500

27696

265000

77667

1897 / 4020

885 / 34.8

1640 / 64.6

1040 / 40.9

140 / 308.6

58

27.10

102.58

22.75 / 3.30

17.93 / 2.60

MDB0150BW

157800

46249

118000

34584

329000

96424

2077 / 4400

885 / 34.8

1640 / 64.6

1040 / 40.9

145 / 319.7

59

35.00

132.50

18.96 / 2.75

14.89 / 2.16

Btu/h

W

Btu/h

W

Btu/h

W

l/s / CFM

mmAq

mm/in

mm/in

mm/in

kg/lb

dBA

USGPM

LITRES/M

kPa / psi

kPa / psi

Page 37: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

S12

Chilled Water Fan Coil Unit Specifications

MCE015EW - MCE025EW (Ceiling Convertible)

Notes:1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO13253.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - ENTERING AIR TEMP. : 27ºC (80.6ºF) DB / 19ºC (66.2ºF) WB, ENTERING WATER TEMP. : 7ºC (44.6ºF), LEAVING WATER TEMP. : 12ºC (53.6ºF)b) HEATING - ENTERING AIR TEMP.: 20ºC (68ºF) DB, ENTERING WATER TEMP. : 70ºC (158ºF), LEAVING WATER TEMP. : 65ºC (149ºF)

4) SOUND PRESSURE LEVEL ARE TESTED IN ANECHOIC CHAMBER AND ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT

MCE015EW MCE020EW MCE025EW

15500 20300 21000

4540 5950 6160

12700 15400 16200

3720 4520 4740

19500 25000 28000

5720 7330 8210

HIGH 245 / 519 273 / 579 293 / 619

MEDIUM 217 / 460 250 / 530 269 / 570

LOW 192 / 406 231 / 490 245 / 520

HEIGHT

WIDTH

DEPTH

27 / 59.7 27 / 59.7 28 / 61.9

48 / 46 / 43 50 / 47 / 46 51 / 48 / 47

3.43 4.49 4.67

13.00 17.00 17.67

28 / 4.0 48 / 7.0 57 / 8.3

24 / 3.5 42 / 6.1 50 / 7.3HEAD LOSS (HEATING) : 50ºC

CONNECTION 1/2" BSP FEMALE ADAPTOR

UNIT WEIGHT

SOUND PRESSURE LEVEL ( H/M/L )

NOMINAL WATER FLOW RATE

HEAD LOSS (COOLING)

NOMINAL AIR FLOW

UNIT DIMENSION

212.5 / 8.4

1090 / 42.9

630 / 24.8

MODEL

NOMINAL TOTAL COOLING CAPACITY

NOMINAL SENSIBLE COOLING CAPACITY

NOMINAL TOTAL HEATING CAPACITY (ENTERINGWATER TEMP. = 70ºC)

Btu/h

W

Btu/h

W

Btu/h

W

l/s/CFM

l/s/CFM

l/s/CFM

mm/in

mm/in

mm/in

kg/lb

dBA

USGPM

LITRES/M

kPa/psi

kPa/psi

Page 38: Chilled Water System Solution - Acson International SELLING KIT/CATALOG/AP-MSM-0… · the operation of fan coil unit and chiller in a complete McQuay chilled water product system

A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration.

Products manufactured in an ISO certified facility.This document contains the most current product information as of this printing.

For the most up-to-date product information, please go to www.mcquay.com.

© 2008 McQuay International +1 (800) 432-1342 www.mcquay.com