catálogo camag

Upload: arnaldo-santos-gomes

Post on 17-Oct-2015

285 views

Category:

Documents


7 download

DESCRIPTION

Materiais de Cromatografia

TRANSCRIPT

  • 5/27/2018 Cat logo CAMAG

    1/27

    Basic Equipment forModern Thin-Layer Chromatography

    World leader in Planar Chromatography

  • 5/27/2018 Cat logo CAMAG

    2/27

    CAMAG has a tradition of service to Planar Chromatography since 1961. We develop and manufacturebasic equipment, sophisticated instruments and software for this analytical technique.

    We provide competent customer support and technical service for our products as well as education,training, application support and a range of contract laboratory services.

    CAMAG has everything your lab may need for Planar Chromatography. This catalog focuses on the basicequipment suitable for your TLC/HPTLC application.

    For further information on the full range of CAMAG products including instruments see our maincatalogue or the special brochures.

    Please visit our home page www.camag.comfor additional information and latest news.

    2

    Environment Water

    Soil

    Residue analysis, etc.

    Clinical applications Lipids

    Metabolism studies

    Drug screening

    Doping control, etc.

    Food and Feed stuff Quality control

    Additives (e. g. vitamins)

    Pesticides

    Stability tests (expiration), etc.

    Pharmaceutical applications Quality control

    Content Uniformity Test (CUT)

    Identity- and purity checks

    Stability tests, etc.

    Industrial applications Process development and

    optimization

    Process monitoring

    Cleaning validation, etc.

    Forensics Detection of document forgery

    Investigation of poisoning

    Dyestuff analyses, etc.

    Herbals Identification

    Stability tests

    Detection of adulteration

    Assay of marker compounds, etc.

    Cosmetics Identity of raw material

    Preservatives, colouring materials, etc.

    Screening for illegal substances, etc.

    Important fields of application

  • 5/27/2018 Cat logo CAMAG

    3/273

    Index

    The steps of Planar Chromatography ____________________________________________________4

    Sample Application, Sample Dosage

    Chromatogram Development

    Derivatization

    Chromatogram Evaluation

    Optional Procedures

    Sample Application __________________________________________________________________

    5Nanomat 4 and Capillary DispenserDisposable Glass Capillaries

    Graduated Disposable Micropipettes

    Multi Purpose Spotting Guide

    Chromatogram Development ________________________________________________________ 68

    Twin Trough Chamber

    Flat Bottom Chamber

    smartAlert Solvent Front Monitor

    Horizontal Developing Chamber

    HPTLC Vario SystemDerivatization ____________________________________________________________________910

    Chromatogram Immersion Device

    TLC/HPTLC Sprayer

    Reagent Spray

    TLC Spray Cabinet

    TLC Plate Heater

    Chromatogram Evaluation ___________________________________________________________ 11

    UV Cabinet

    UV Lamps

    Chromatographic Layers and Accessories ____________________________________________ 1215Precoated Layers for HPTLC and TLC

    TLC Plate Coaters

    Glass Plates for Thin-Layer Chromatography

    smartCUT Plate Cutter

    Drying Rack

    TLC Plate Box

    Test Dye Mixtures

    Adsorbents for In-House Preparation of TLC Layers

    Basic TLC Assemblies ________________________________________________________________ 16

    TLC Basic Kit

    HPTLC Basic Kit

    CAMAG Services ________________________________________________________________ 1719

  • 5/27/2018 Cat logo CAMAG

    4/274

    The Steps of Planar Chromatography:

    Sample application, sample dosageThe samples are applied onto the separation layer, either as spots through contact transfer or as narrow bandsusing the spray-on technique. Precision of applied volume, small size of application zone and exact positioning areessential for the quality of the analysis. Bandwise sample application as available with Linomat 5 or Automatic TLCSampler 4 (ask for brochure) offers the best separation results and highest flexibility regarding sample solvents andapplication volumes. With spray-on technique the applied volume can be easily adjusted to match the requireddetection limit of the analytical task.

    Chromatogram development

    Drawn by capillary forces the developing solvent (mobile phase) migrates through the layer(stationary phase) over a defined distance. During this process the sample is separated into fractions (components).After evaporation of the mobile phase all fractions remain stored on the layer.

    Special features: Almost unlimited choice of mobile phase and large selection of stationary phases.

    Derivatization

    It is an inherent advantage of planar chromatography that fractions are stored on the plate and can be derivatizedafter chromatography. By derivatization, substances that do not respond to visible or UV light can be rendereddetectable. In many cases, substances or classes of substances can be identified by specific reagents.

    Chromatogram evaluation

    The chromatogram is evaluated under ultraviolet or white light. Options range from visual inspection, electronicimage processing, video densitometry and documentation to quantitative determination by means of monochromaticlight in a classical densitometer, which additionally facilitates measurement of spectral information.Spectral information is available through the densitometer.

    Special features: Multiple evaluation of the chromatogram with different parameters and detection methods.

    If necessary a derivatization step can be interposed.

    Optional Procedures

    UV-InspectionPostchromatographic Derivatization StainingIn-House Preparation of TLC PlatesPrecoated Layers

    Synonyms for Planar Chromatography Thin-Layer Chromatography (TLC) or High Performance Thin-Layer Chromatography (HPTLC)

    Modern Thin-Layer Chromatography

    Instrumental Thin-Layer Chromatography

    Planar Liquid Chromatography (PLC) (rarely used)

    In order to emphasize the fact that the modern method is different from the simple thin-layer chromatography of yesterday, we are predo-minantly using Planar Chromatography but occasionally TLC or HPTLC as well.

  • 5/27/2018 Cat logo CAMAG

    5/275

    The System CAMAG Nanomat and

    Capillary Dispenser

    Ordering information

    022.4730 Nanomat 4, without Capillary

    Pipettes and holder022.7650 Capillary Dispenser complete

    with Universal Capillary Holder022.7786, one Dispenser Maga-zine 022.7661 for 1 L Capillariesand one pack of 5 x100Disposable Capillary Pipettes 1 L

    022.7655 Capillary Dispenser, withoutCapillary Pipettes

    022.7786 Universal Capillary Holder

    022.7660 Dispenser Magazine for 0.5 LCapillary Pipettes, without Capillaries

    022.7661 Dispenser Magazine for 1.0 LCapillary Pipettes, without Capillaries

    022.7662 Dispenser Magazine for 2.0 LCapillary Pipettes, without Capillaries

    022.7665 Dispenser Magazine for 5.0 LCapillary Pipettes, without Capillaries

    022.7770 Disposable Capillary Pipettes0.5 L, pack of 5 x100

    022.7771 Disposable Capillary Pipettes1.0 L, pack of 5 x100

    022.7772 Disposable Capillary Pipettes2.0 L, pack of 5 x100

    022.7775 Disposable Capillary Pipettes5.0 L, pack of 5 x100

    The CAMAG Nanomat serves for easy applica-tion of samples onto TLC and HPTLC plates orsheets, in the form of spots, precisely positionedand without damage to the layer.

    The actual sample dosage is performed withdisposable capillary pipettes which are preciselyguided by the Universal Capillary Holder.

    The Nanomat is suitable for:

    Conventional TLC plates including self-coatedplates up to 20 x 20cm

    HPTLC plates 10 x 10cm and 20 x 10cm

    TLC and HPTLC sheets up to 20 x 20cm.

    Capillary pipettes are loaded into the dispenserin magazines. Capillaries of 0.5, 1, 2, and 5L

    volume are available. Each capillary size requiresan appropriate dispenser magazine.

    With the Universal Capillary Holder capillarypipettes are taken from the dispenser, filled withsample solution and then placed against theapplicator head of the Nanomat.

    Ordering information

    022.7725 Disposable Capillaries 0.5 L,vial of 100

    022.7726 Disposable Capillaries 1.0 L,vial of 100

    022.7727 Disposable Capillaries 2.0 L,vial of 100

    022.7729 Disposable Capillaries 5.0 L,vial of 100

    022.7142 Graduated Disposable Micropipettes5 L, pack of 250

    022.4230 CAMAG Multipurpose SpottingGuidefor 20 x20 cm plates,with scoring pin

    Alternative techniquesfor manual sample applicationThe tools presented here are intended for less demanding tasks in the TLC lab.

    Disposable glasscapillaries

    Disposable glass capillaries for manual sampleapplication of 0.5, 1, 2, or 5 L

    color coded vials containing 100 pieces

    The capillaries are hand-held and can be posi-tioned with the Multipurpose Spotting Guide.

    Graduated disposable micropipettes

    Graduated in microliters, these 5 L glasscapillaries are suitable for qualitative analysison conventional TLC layers

    MultipurposeSpotting Guide

    The CAMAG Multipurpose Spotting Guideis used for setting up chromatograms onconventional 20 x20 cm layers

    The Multipurpose Spotting Guide can also

    be used in combination with the CapillaryDispenser system (see Nanomat 4) to makemanual sample application more convenient.

    Sample Application

  • 5/27/2018 Cat logo CAMAG

    6/276

    Chromatogram Development

    Twin Trough Chamberlight-weightTwin Trough Chamber light-weight with glass lid.Made from highly transparent sheet glass.

    Twin Trough ChamberTwin Trough Chamber with stainless steel lid

    CAMAG Twin Trough chambers offer several ways to specifically affect the TLC/HPTLC separation in order to improve it.

    Twin Trough Chamber

    Ordering information

    Twin Trough Chamber for 20x20 cm plates

    022.5256 with stainless steel lid

    022.5255 with glass lid

    022.5258 without lid

    Twin Trough Chamber for 20x10 cm plates

    022.5254 with stainless steel lid

    022.5253 with glass lid

    022.5251 without lid

    Twin Trough Chamber for 10x10 cm plates

    022.5155 with stainless steel lid

    022.5156 without lid

    Twin Trough Chamber for 10x5 cm plates

    022.5165 with stainless steel lid

    022.5166 without lid

    Twin Trough Chamber light-weight

    022.5285 for 20 x20 cm plates with glass lid

    022.5280 for 20 x10 cm plates with glass lid

    Flat Bottom Chamber for 20x20 cm plates

    022.5259 with stainless steel lid

    022.5250 with glass lid

    022.5257 without lid

    Flat Bottom Chamber for 10x10 cm plates

    022.5150 with stainless steel lid

    022.5151 without lid

    022.5265 Stainless steel lid to fit 20 x20 cmand 20 x10 cm chambers, not forlightweight chambers

    022.5102 Stainless steel lid for 10x10 cmchambers

    022.5252 Glass lid for 20x20 cm and 20x10 cmchambers (not for light-weightchambers)

    Flat Bottom Chamber light-weight

    022.5275 for 20 x20 cm plates, with glass lid022.5270 for 20 x10 cm plates, with glass lid

    022.5279 Glass lid for all light-weight chambers,20x20 and 20x10 cm

    Low solvent consumption

    20 mL of solvent is sufficient for the develop-ment of a 20x20 cm plate, 10 mL for a 20x10 cm,and 5 mL for a 10 x10 cm HPTLC plate. This notonly saves solvent, but also reduces the wastedisposal problem.

    Reproducible pre-equilibrationwith solvent vapor

    For pre-equilibration, the TLC plate is placed inthe empty trough opposite the trough, whichcontains the solvent. Equilibration can be per-formed with any liquid and for any period of time.

    Start of development

    Development is started only when developingsolvent is introduced into the trough with theplate.

    The CAMAG Flat Bottom chamber permits the chromatogram to be developed under con-ditions of partial or complete saturation of the tank atmosphere with solvent vapors. Thedegree of layer pre-saturation can not be controlled unless additional accessories are used.

    Flat Bottom Chamber

    Flat Bottom ChamberFlat Bottom Chamber with stainless steel lid

    Flat Bottom Chamberlight-weightFlat Bottom Chamber light-weight with glass lid

  • 5/27/2018 Cat logo CAMAG

    7/277

    Saturation padsThese 20 x20 cm sheets of thick filter paper are used to line the inner walls of a developing tank forsaturating the chamber atmosphere with solvent vapors. They are suitable for all Flat Bottom and TwinTrough Chambers. These pads are also handy for many other uses in a TLC laboratory.

    In the Horizontal Developing chamber, the HPT-LC plate is developed from both opposing sides

    towards the middle. This permits the numberof samples to be doubled as compared withdevelopment in a tank, provided the separationdistance of 45 mm, i.e. 50 mm minus 5 mmdistance from the edge, is sufficient. In theCAMAG Horizontal Developing chamber, a platecan be developed in the sandwich as well as inthe tank configuration.The chamber is suitablefor all kinds of solvents.

    Horizontal Developing Chamber

    1 HPTLC plate (layer facing down)

    2 Glass plate for sandwich configuration

    3 Reservoir for developing solvent

    4 Glass strip

    5 Cover plate

    smartALERT for dependable monitoring of TLC/HPTLC plate development in a glass developmentchamber.

    Guarantees that the developing distancewill always be accurate and according to themethod

    Gives acoustic and visual notice when themobile phase has reached the desireddeveloping distance

    Replaces the timer or stop watch

    Works with glass chambers for plate sizes20 x20 cm, 20 x10 cm and 10 x10 cm

    No wastes because of over-developed plates.

    Ordering information

    022.5300 smartALERT Solvent Front Monitor

    Ordering information

    022.5244 Saturation Pads, pack of 100

    Ordering information

    Horizontal Developing Chamber

    022.8530 for 10 x10 cm plates

    022.8535 for 20 x10 cm plates

    smartALERT

    Solvent Front Monitor

  • 5/27/2018 Cat logo CAMAG

    8/278

    1Optimization of the

    developing solvent

    Development with six different solvents side by side, without precondi-tioning = development in sandwich configuration.

    Timesaving optimization of separationconditions using the HPTLC Vario SystemApplication examples, schematic

    2Optimization of thedevelopment solvent

    Development with six different solvents side by side whereby the conditio-ning troughs contain the same six solvents = simulated tank development

    3Optimization of thedevelopment solvent afteruniform layerpreconditioning

    First step: pre-equilibration of all six tracks with the same conditioning

    liquid; then development with six different solvents (in sandwichconfiguration).

    4Optimization

    of preconditioningPre-equilibration with six different conditioning liquids; then develop-ment of all tracks with the same solvent.

    F1 = developing solvents C1 = conditioning liquids

    HPTLC Vario System

    Key features:

    Development with six different solvents can be tested side by side.

    Sandwich as well as tank configuration can be simulated side by side,making results directly comparable.

    Six different conditions of pre-equilibration, including relative humidity,can be tested simultaneously.

    These variations of developing conditions can be freely combined.

    Chromatogram Development

    Ordering information

    022.8550 HPTLC VARIO System, comprising

    022.8555 HPTLC VARIO Chamber for 10 x10 cm plates,complete and

    022.8556 HPTLC Scoring unit for the preparation ofTLC/HPTLC plates

    022.8558 Scoring blades for 022.8556, pack of 10

  • 5/27/2018 Cat logo CAMAG

    9/279

    Chromatogram Immersion Device

    Ordering information

    022.6606 Chromatogram Immersion Device III for plates up to20 x20 cm, without dip tank

    022.6627 Dip tank (sintered sheet glass) for plates 20x20 cm,with lid

    022.6628 Dip tank (sintered sheet glass) for plates 20x10 cm,with lid

    022.6622 Lid, polyethylene, for dip tanks 20x20 cm and20 x10 cm

    022.6619 Bench top rack for three dip tanks

    TLC/HPTLC-Sprayer

    The TLC/HPTLC Sprayer consists of a charger and a pump unit with twokinds of spray heads. Spray head type A is for spray solutions of normalviscosity, e.g. lower alcohol solutions; spray head type B is for liquids ofhigher viscosity, e.g. sulfuric acid reagents.

    Key features:

    Easy to use, with electro-pneumatic spray function

    Formation of fine aerosol with particles of 0.3 to 10 m

    Ordering information

    022.6530 TLC Sprayer comprised of charger unit, pump unit with bottleclamp and connecting tube, one each spray head type A and B,one each reagent bottle 100 mL and 50 mL with cap

    Spares and consumables:

    022.6535 Pack of 5 spray heads type A and 1 type B

    022.6538 Pack of 6 spray heads type B

    022.6536 Reagent bottle 100 mL with cap, pack of 6

    022.6537 Reagent bottle 50 mL with cap, pack of 6

    022.6539 Service kit for TLC sprayer containing 2 compressed air con-nectors, 5 gaskets, 3 changeable filters, 1 bottle holder

    For proper execution of the dipping technique, the chromatogram must beimmersed and withdrawn at a controlled uniform speed. By maintaining awell defined vertical speed and immersion time, derivatization conditionscan be standardized and tide marks, which can interfere with densito-metric evaluation, are avoided .

    Key features:

    Uniform vertical speed, freely selectable between 30 mm/s and 50 mm/s.

    Immersion time selectable between 1 and 8 seconds and indefinitely

    The device can be set to accommodate 10 cm and 20 cm plate height

    Battery operated, independent of power supply.

    Derivatization

  • 5/27/2018 Cat logo CAMAG

    10/2710

    Derivatization

    Reagent Sprayer (all glass)

    This all glass reagent sprayer is a low cost yet efficient alternative to theTLC/HPTLC Sprayer. It comes with a rubber pump but may also be operatedfrom a compressed air or nitrogen supply.

    Ordering information

    022.6100 Reagent Sprayer, all glass, with 100 mL Erlenmeyer flask

    Spare parts:

    022.6101 Spray head for 022.6100

    022.6102 Erlenmeyer flask for 022.6100

    022.6103 Rubber pump for 022.6100

    TLC Spray Cabinet

    The TLC Spray Cabinet ensures the complete removal of reagent mist whilespraying TLC plates.

    There is no deflection of the spray jet before it reaches the chromatogram,an effect often occurring in a normal laboratory fume hood.The TLC Spray Cabinet is made of PVC.

    The blower, a radial fan driven by a motor outside of the fume duct,produces an airflow of 130 cubic feet per minute. The bottom of the spraycabinet has a built in tray, which is removable for easy cleaning. Dimensi-ons: 470 x490 x490 mm (width xdepth xheight)

    TLC Plate HeaterThe TLC Plate Heater is designed for heating TLC plates to a given tempera-ture, while ensuring homogenous heating across the plate.

    The TLC Plate Heater III has a CERANheating surface which is resistant toall common reagents and is easily cleaned. The 20 x20 cm heating surfacehas a grid to facilitate correct positioning of the TLC plate.

    Programmed and actual temperature are digitally displayed. The tempe-rature is selectable between 25 and 200 C. The plate heater is protectedfrom overheating.

    Ordering information

    022.6230 TLC Spray Cabinet II with blower and 1.5 m flexible exhausthose 127 mm .

    022.6232 TLC Spray Cabinet II without blower, with 1.5m flexibleexhaust hose (for connection to an existing exhaust duct)

    022.6226 exhaust hose extension 1.5 m with adapter

    Ordering information

    022.3306 TLC Plate Heater III

  • 5/27/2018 Cat logo CAMAG

    11/2711

    UV Lamp in combination with UV ViewingBox (= UV Cabinet)

    The UV Cabinet is suitable for inspecting thin-layer chromatograms and other objects in anundarkened room. The front of the box is closedwith a roller shutter, which can be pushed opento the left or to the right as required for insertingor marking objects. A glass filter in the viewingwindow protects the eyes against reflectedshort-wave UV light. Great care has been taken

    to ensure the correct distances between UV lamp,object and the observers eye in the interest ofgood illumination and untroubled viewing.

    Key features:

    Inspection of thin-layer chromatograms andother objects in an undarkened room

    A glass filter in the viewing window protectsthe eyes against reflected short-wave UV light

    Made from shock-resistant plastic

    Base measures 400x260 mm inside; outerdimensions 490 x350 x290 mm

    Compatible with all CAMAG UV lamps of the022.91XX series.

    UV Cabinet Hardly any TLC laboratory can be without theuse of UV light for inspecting chromatograms.

    Two types of ultraviolet light are required forinspecting thin-layer chromatograms:

    Long-wave UV light 366 nm:Under long-wave UV light substances thatcan be excited to fluoresce appear as brightspots, often differently colored, on a darkbackground. The sensitivity of this detectionmethod increases with the intensity of theUV light and also as more visible light iseliminated.

    Short-wave UV light 254nm:Under 254 nm UV substances absorbing atthat wavelength become visible, providedthe TLC layer contains a fluorescent indi-cator, e.g. F254. These substances appearas dark spots on a bright background.UV intensity and complete elimination ofvisible light are less critical.

    Ordering information

    022.9070 UV Cabinet consisting of:022.9120 UV-Lamp for two wavelengths 254/366nm, 2 x8 W

    022.9055 CAMAG Viewing Box 3

    022.9055 Viewing Box 3, for all UV lamps ofthe 022.91XX series

    022.9120 UV Lamp dual wavelength,254/366 nm, 8 W each

    022.9110 UV Lamp short-wave UV, 254 nm,2 x 8 W

    022.9115 UV Lamp long-wave UV, 366 nm,2 x 8 W

    022.9145 Stand for CAMAG UV Lamps

    022.9146 Adapter for operating the cigarette

    lighter socket of a carSpare parts:

    352.0010 Light tube short-wave UV, 254 nm,8 W

    352.0011 Light tube long-wave UV, 366 nm,8 W

    692.0042 UV Filter glass for UV lamps of the022.91XX series

    The UV lamps with stand are designed foruse in a TLC laboratory.

    The housing is made of anodized aluminum andof shock-resistant plastic. The lamp is operatedon 12 V AC or DC power which is internallyconverted to 2530 KHz high frequency. This en-sures instantaneous illumination of the tubes atthe selected wavelength as well as the absenceof any flickering. In order to reduce the usersrisk of exposure to UV radiation, the lamp is

    equipped with a timer that automaticallyturns off after 10 minutes.

    The stand holds the lamp in a position optimizedfor viewing 20 x20 cm objects. It shields offextraneous light on three sides. The lamp can beeasily lifted off the stand and directed against alarger object.

    Key features:

    Two wavelengths, 254/366 nm

    Two light tubes 8 W each

    Shock resistant housing

    Dimension 442 x76 x43 mm

    Powered with 12 V AC from the mainsadapter supplied with it or via an optionalconnecting cable from 12 V DC.

    Instantaneous ignition without flickering andoptimum light efficiency due to operation at2530 KHz AC.

    Automatic switch off by timer after 10 minreduces the risk of exposure to radiation.

    UV Lamps

    Chromatogram Evaluation

  • 5/27/2018 Cat logo CAMAG

    12/2712

    TLC/HPTLC Precoated Layers

    Performing thin-layer chromatographic sepa-ration on HPTLC layers has several advantagesover those on conventional layers:

    Higher resolution of zones due to highernumber of theoretical plates

    Shorter developing times

    Less solvent consumption

    Less background noise due to narrow sizedistribution of particles

    However, suitable instruments are required toget the best results.

    In most cases instrumental thin-layer chroma-tography utilizes precoated layers. Not onlyare they more convenient, their quality is farsuperior to that of layers prepared from theadsorbents available for self-coating.The precoated layers have a smoother andmore durable surface.

    The following list contains a selection of the most common precoated plates and sheets manufacturedby E. MERCK. However all MERCK TLC/HPTLC plates and sheets can be ordered through CAMAG.

    layer size quantity(m) (cm) per pack

    034.5631 HPTLC plates silica gel 60 (without F) ................200 ................10 x10 .....................25

    034.5633 HPTLC plates silica gel 60 (without F) ................200 ............... 10 x10...................100

    034.5641 HPTLC plates silica gel 60 (without F) ................200 ............... 20 x10.....................50

    034.5628 HPTLC plates silica gel 60 F 254 ................... ....200 ............... 10 x10.....................25

    034.5629 HPTLC plates silica gel 60 F 254 ................... ....200 .............. 10 x10...................100034.5642 HPTLC plates silica gel 60 F 254 ................... ....200 .............. 20 x10.....................50

    034.5648 HPTLC plates silica gel 60 F 254,ultra pure for pharmacopoeial methods .............200 .............. 20 x10 . ................... 50

    034.5613 HPTLC plates silica gel 60 F 254 GLP ............. ...200 .............. 20 x10.....................25

    034.1552 HPTLC plates silica gel 60 WR F 254s ................200 ............... 20 x10.....................25

    034.5445 HPTLC plates LiChrospherSi 60 F 254s ....... ....180 ............... 20 x10.....................25

    034.5647B HPTLC plates LiChrospherSi 60 WRF 254s ......100 ............... 20 x10.....................25

    034.5547 HPTLC aluminium sheets silica gel 60 (without F) ...200 .............. .. 20 x20.....................25

    034.5548 HPTLC aluminium sheets silica gel 60 F 254 ..........200 .............. 20 x20.....................25

    034.3726 HPTLC plates RP-2 F 254s .................................200 .............. 10 x10.....................25034.3725 HPTLC plates RP-8 F 254s .................................200 ............... 10 x10.....................25

    034.3124 HPTLC plates RP-18 W F 254s ...........................200 ............... 10 x10.....................25

    034.3724 HPTLC plates RP-18 F 254s ...............................200 ............... 10 x10.....................25

    034.6464 HPTLC plates CN F 254s ....................................200 ............... 10 x10.....................25

    034.2668 HPTLC plates Diol F 254 ....................................200 ............... 10 x10.....................25

    034.5647A HPTLC plates NH2 F 254s ..................................200 ............... 10 x10.....................25

    MERCK Pre-coated Layersfor (conventional) TLClayer size quantity .

    (m) (cm) per pack

    034.5721 TLC plates silica gel (without F) .........................250 ................20 x20 ....................25

    034.5729 TLC plates silica gel 60 F 254 ......................... ..250 ................10 x20 ....................50

    034.5715 TLC plates silica gell 60 F 254 ......................... .250 ................20 x20 ....................25

    034.1798 TLC plates silica gel 60 F 254,concentration zone ..........................................250 ................20 x20 ....................25

    034.5554 TLC aluminium sheets silica gel 60 F 254 ..........200 ................20 x20 ....................25

    034.5559 TLC aluminium sheets RP-18 F 254s .................200.................20x20 ....................20

    034.5804 LuxPlate Si 60 F254 ..........................................250 ................20 x10 ....................50

    034.5805 LuxPlate Si 60 F254 ..........................................250 ................20 x20 ....................25

    MERCK Precoated Layers for High Performance

    Thin-Layer Chromatography (HPTLC)

    This selection of Merck precoated platesrepresents only a selection of frequently usedplates. The complete line of Merck precoatedplates can be found at www.tlc.merck.de.On request CAMAG can deliver any platefrom the Merck line.

  • 5/27/2018 Cat logo CAMAG

    13/2713

    In-House Preparation of TLC Plates

    Automatic TLC Plate CoaterThe glass plates to be coated are conveyed underneath a hopper filled with the adsorbent suspension.

    The layer thickness is determined by either a fixed gate with pre-set spacers or by a gatewith adjustable distance.

    The plates are moved by a motorized conveying system at a uniform feeding rate of 10 cm/s, to ensurea uniform layer. The Automatic TLC Plate Coater is supplied with a fixed gate for pre-set layers of 300and 500 microns, an adjustable gate for layer thicknesses 02mm, and one plate holder for eight20 x20 cm plates.

    TLC Plate Coater, hand operatedThe manual plate coater functions in the same manner as the automatic coater, except with this modelthe plates are pushed through by hand, one after the other and lifted off on the other side. The TLCPlate Coater is shipped with a fixed gate for pre-set layers of 300 and 500 microns and an adjustablegate for layer thicknesses 02 mm.

    Ordering information

    022.1602 Automatic TLC Plate Coater

    022.1612 Additional Plate Holder for 022.1602

    022.1251 TLC Plate Coater, hand operated

    022.1216 Fixed Gate, special, two thicknesses up to 1 mm*

    022.1217 Fixed Gate, special, two thicknesses one or both 1 mm up to 2 mm*

    *when ordering please specify thickness for each side

    Ordering information

    022.0260 CAMAG TLC Package Plate Coating Automatic, containing:

    022.1602 Automatic TLC Plate Coater

    3 x 022.2200 Glass Plates 20 x20 cm, pack of 10

    2 x 022.3250 TLC Plate Box

    032.3401 Aluminum Oxide CAMAG DSF-O, 1 kg

    032.3562 Cellulose CAMAG DSF-O, 500 g

    033.7730 Silica Gel MERCK GF 254, type 60, 1 kg

    022.0265 CAMAG TLC Package Plate Coating Manual, containing:

    022.1251 TLC Plate Coater, hand operated

    2 x 022.2200 Glass Plates 20 x20 cm, pack of 10

    022.3250 TLC Plate Box

    032.3401 Aluminum Oxide CAMAG DSF-O, 1 kg

    032.3562 Cellulose CAMAG DSF-O, 500 g

    033.7730 Silica Gel MERCK GF 254, type 60, 1 kg

    Complete systems for in-house preparation of TLC platesThe following plate coating packages have been carefully composed so that you can immediately startin-house preparation of conventional TLC plates.

    Ordering information

    022.2200 Glass Plates 20 x20 cm, pack of 10

    022.2100 Glass Plates 10 x20 cm, pack of 10

    Glass plates for Thin-Layer ChromatographyGlass plates with polished edges,about 4 mm thick

  • 5/27/2018 Cat logo CAMAG

    14/2714

    Ordering information

    CAMAG offers three different test dye mixtures:

    032.8001 Test Dye Mixture I 100 mL Dimethyl yellow Oracet blue 2R Oracet red G;solvent: toluene

    032.8002 Test Dye Mixture II 100 mL (especially for aluminum oxide) Sudan black Artisil blue Sudan yellow fatty orange fat red 7B (Sudan black separates into two fractions);solvent: toluene

    032.8003 Test Dye Mixture III 10 mL (suitable for HPTLC silica gel) Ciba F II Indophenol Ariabel red Sudan blue II Sudan IV dimethylaminoazobenzene;solvent: toluene

    Test Dye MixturesTest dye mixtures are useful for functional checks on individual steps in the TLC procedure and forstudying the influence of specific parameters.

    Drying RackThe Drying Rack consists of ten individual aluminum trays, 20x20 cm, which can be stacked quicklyand conveniently. A tin box for storing the trays and two wire handles, to move the stack while hot,are supplied.

    The Drying Rack is convenient to use, particularly when TLC plates are prepared with the automaticplate coater in large runs. The Drying Rack also comes in handy for plates smaller than 20 x20 cm.

    TLC Plate BoxThe TLC Plate Box holds ten 20 x20 cm plates. The body with slide rails, the handle, and the removablebottom are all made of stainless steel. The cover is of transparent plastic. When used for drying coatedTLC plates, the bottom and the cover are removed to increase air circulation.

    The TLC Plate Box is also recommended to re-activate 20 x20 cm pre-coated plates, e.g. after theyhave been pre-washed.

    Ordering information

    022.3200 Drying Rack

    Ordering information

    022.3250 TLC Plate Box

    smartCUT Plate CutterCuts plates with a thickness up to 3 mm

    Does not damage the sensitive layer

    Easy to handle.

    Read the required size from the scale directly

    Helps saving costs on precoated plates of high quality by preventing offcuts.

    Ordering information

    022.4300 smartCUT Plate Cutter

    115.4305 Spare cutter

    In-House Preparation of TLC Plates

  • 5/27/2018 Cat logo CAMAG

    15/2715

    Adsorbents for In-House Preparation of TLC Layers

    Ordering information 500 g 1 kg 2,5 kg 5 kg

    CAMAG Adsorbents

    Aluminium Oxide CAMAG DS-0 032.3301 032.3305

    Aluminium Oxide CAMAG DS-5 032.3351 032.3355

    Aluminium Oxide CAMAG DSF-0 032.3401 032.3405

    Aluminium Oxide CAMAG DSF-5 032.3451 032.3455

    Cellulose, fibre type, CAMAG D-0 032.3502

    Cellulose, fibre type, CAMAG DF-0 032.3512

    Cellulose, microcrystalline, CAMAG DS-0 032.3552

    Cellulose, microcrystalline, CAMAG DSF-0 032.3562

    Silica Gel, CAMAG DS-0 032.1001 032.1005

    Silica Gel, CAMAG DS-5 032.1051 032.1055

    Silica Gel, CAMAG DSF-0 032.1101 032.1105

    032.1151 Silica Gel, CAMAG DSF-5 032.1151 032.1155

    Ordering information 500 g 1 kg 2,5 kg 5 kg

    MERCK Adsorbents

    Aluminium Oxide MERCK G (type 60/E) 033.1090 033.1091

    Aluminium Oxide MERCK GF (type 60/E) 033.1092

    Aluminium Oxide MERCK H basic (type 60/E) 033.1085

    Aluminium Oxide MERCK HF basic (type 60/E) 033.1094

    Silica Gel MERCK G (type 60) 033.7731 033.7733

    Silica Gel MERCK GF (type 60) 033.7730 033.7729

    Silica Gel MERCK H (type 60) 033.7736 033.7738

    Silica Gel MERCK HF (type 60) 033.7745 033.7739

    Silica Gel MERCK HF 254 + 366 (type 60) 033.7741

    Silica Gel MERCK 60 HR high purity 033.7744

    Kieselguhr MERCK 60 G 033.8129

    For the self preparation of chromatographic layers,adsorbents in the form of powder are mixedwith water or with aqueous solutions of salts orbuffering compounds to form a thick slurry whichis spread onto glass plates by means of a coatingdevice.

    Adding calcium sulfate as a binder makes iteasier to achieve the correct consistency of theslurry for coating; the calcium sulfate contributesvery little to the mechanical strength of the layer.

    A fluorescence indicator is required to visualizesubstances which absorb UV light of a wave-length (254 nm), by which the indicator is excitedto emit visible light. Such substances appear asdark spots on a bright background.The fluorescence indicator does not interfere withthe chromatographic separation, with any deriva-tization reactions, nor with densitometricevaluation. Most of these type indicators, how-ever, lose their fluorescence on contact with acids.Fluorescence indicators which are stable againstacids are only available in certain precoated layers.

    CAMAG offers a wide range of TLC adsorbents

    of its own manufacture as well as products byE. MERCK. The following list contains a selectionof the more common grades.However, all MERCK TLC adsorbents may beordered through CAMAG.

    F = Fluorescence indicator excitation wavelength 254 nm

    F 254 + 366 = Fluorescence indicator excitation wavelength 254 and 366 nm

    G = CaSO4 (gypsum) 13% in silica gel, 9% in aluminium oxide

    last digit: 5 = 5% CaSO4 binder, 0 = 0% = no CaSO4 binder

  • 5/27/2018 Cat logo CAMAG

    16/2716

    All CAMAG basic kits have been carefully composed so that the lab can start working withThin-Layer Chromatography. These assemblies are configured to allow upgrading to a comple-te system for quantitative TLC by adding items at any time without making any tool redun-dant. The transition from conventional TLC material to so-called high-performance (HPTLC)layers is straightforward. Just add the appropriate instrumentation.

    Ordering information

    022.0216 TLC Basic Kit, including UV Cabinet for qualitative and quantitative TLC using conventional layers,consisting of:

    022.4730 CAMAG Nanomat 4, without capillary pipettes and holder

    022.7650 CAMAG Capillary Dispenser complete with Universal Capillary Holder 022.7786, one Dispenser Magazine for 1 L CapillaryPipettes 022.7661 and one pack of 5 x100 Disposable Capillary Pipettes 1 L 022.7771

    022.7662 Dispenser Magazine for 2 L Capillary Pipettes

    022.7665 Dispenser Magazine for 5 L Capillary Pipettes

    022.7772 Disposable Capillary Pipettes 2 L, pack of 5 x100

    022.7775 Disposable Capillary Pipettes 5 L, pack of 5 x100

    2 x 022.5256 CAMAG Twin Trough Chamber 20 x20 cm, with stainless steel lid

    022.5300 smartALERT, solvent front monitor

    022.5244 Saturation pads, pack of 100

    022.6100 CAMAG Reagent Sprayer, all glass

    034.5715 Precoated plates Merck Silica gel 60 F254, 20 x20 cm, pack of 25

    032.8001 CAMAG Test Dye Mixture I, 100 mL 022.9070 CAMAG UV Cabinet 3 consisting of 022.9120 UV Lamp dual wavelength, 254/366 nm, 8 W each

    022.0226 HPTLC Basic Kit, including UV Cabinet for qualitative and quantitative analyses using 10x10 cm HPTLC layers,consisting of:

    022.4730 CAMAG Nanomat 4, without capillary pipettes and holder

    022.7650 CAMAG Capillary Dispenser complete with Universal Capillary Holder 022.7786, one Dispenser Magazine for 1 L CapillariesPipettes 022.7761 and one pack of 5 x100 Disposable Capillary Pipettes 1 L 022.7771

    022.7660 Dispenser Magazine for 0.5 L capillaries

    022.7770 Disposable Capillary Pipettes 0.5 L, pack of 5 x100

    2 x 022.5155 CAMAG Twin Trough Chamber 10 x10 cm, with stainless steel lid

    022.5300 smartALERT, solvent front monitor

    022.8530 CAMAG Horizontal Developing Chamber 10 x10 cm

    022.5244 Saturation pads, pack of 100

    022.6530 TLC/HPTLC Sprayer

    034.5628 HPTLC plates Merck Silica gel 60 F254,10x10 cm, pack of 25

    032.8003 CAMAG Test Dye Mixture III, 10 mL

    022.9070 CAMAG UV Cabinet 3 consisting of 022.9120 UV Lamp dual wavelength, 254/366nm, 8 W each

    Basic kits

    Basic TLC/HPTLC Assemblies

  • 5/27/2018 Cat logo CAMAG

    17/2717

    CAMAG Laboratory Services

    Further information about our services is available on the Internet:www.camag.com/laboratoryand by Phone: +41 61 467 34 34,Fax: +41 61 461 07 02 or email: [email protected]

    CAMAG Services

    Education and trainingCAMAG Laboratory Services is also your partner when it comes to educa-tion and training in the field of thin-layer chromatography.

    In Muttenz we offer courses on the following subjects:

    Introduction to modern thin-layer chromatography

    Method development

    HPTLC for the analysis of botanicals

    HPTLC for the pharmaceutical industry

    Automated multiple development (AMD).

    The current course dates are available on the Internet at:www.camag.com/courses.For special topics as well as for instrumentand software training we can arrange individual trainings for you.

    CAMAG-Laboratory offers professional HPTLC solutions for your analyticalproblem! The lab has over ten years experience in development of customi-

    zed HPTLC methods. While focusing on the analysis of medicinal plants andproducts derived thereof, expertise is also provided in HPTLC of pharmaceu-ticals, food and beverages as well as environmental and forensic samples.

    Services include:1) Method development and validationDepending on the analytical goal qualitative and quantitative methods aredeveloped from scratch. Existing methods can be customized or optimized.

    2) Feasibility studiesFollowing a detailed discussion of the analytical goal the lab can evaluatewhether HPTLC or TLC is a potential solution. Costs per sample and generalperformance of a method during routine use are estimated. Informationobtained during the experimental work can be transferred to method

    development.3) Contract analysesYour samples are analyzed by HPTLC according to an existing method, e.g.AOAC, USP, PhEur, BHP, PHHelv, PHPRCh, AHP, etc. in an ISO 17025 or GMPcompliant environment. CAMAG-Laboratory can also work according toyour in-house method or employ their own validated methods. In any casean analytical report is generated for each project.

    4) Consulting and trainingCAMAG helps you get started! Whether it is setting up a small lab,ensuring compliance with cGMP, or dealing with the authorities concerningregistration, we can offer HPTLC solutions that save you time, hassleand money.

    Select one of our courses or let us provide customized training at your siteto stay up to date with new developments in HPTLC methodology andtechnology. Let us show you how to properly use your equipment, getreliable results, and develop and validate methods yourself.

    5) Applied researchWe provide opportunities to local1students, scholars, and researchers toengage in research projects at our facilities. Our non-profit projects arefocused on, but are not limited to practical aspects of modern HPTLC andanalysis of botanicals. We publish results in journals, textbooks, throughconferences and seminars as well as on our website. It is our goal to makeavailable to the public high quality data illustrating the capabilitiesof HPTLC.1Greater Basel area

    High-Performance Thin-LayerChromatography for the Analysisof Medicinal PlantsA complete reference for establishing the identity and qualityof botanical products

    Eike Reich, PhD, Head of Laboratory, CAMAG Muttenz, Switzerland, andAnne Schibli, MsPharm, Assistant Head of Quality Control,SwissCo Services AG, Sisseln, Switzerland

    2006, 344 pages/332 illustrated, hardcover, ISBN 3-13-141601-7

    Features: Practical examples provided by

    renowned experts help the readergain a firm understanding of HPTLCmethodologies

    More than 300 full-color imagesand illustrations aid comprehensionof complex concepts

    Easy-to-reference text boxesprovide summaries of key infor-mation ideal for rapid review

    Discussion of the developmentand validation of new HPTLCmethods

    Ordering information

    995.0040 Book HPTLC for the Analysis of Medicinal Plants, Reich/Schibli

  • 5/27/2018 Cat logo CAMAG

    18/2718

    CAMAG Services

    CAMAG application notes describe complete solutions for specific analyticalproblems. In addition they can serve as guide towards solutions for similartasks. To ensure the best results possible, the application notes includedetailed information on:

    Scope and analytical task

    Sample preparation

    Sample application

    Chromatographic conditions

    Post chromatographic derivatization

    Chromatogram evaluation with results.

    The following applications were recently developed:

    Quantitative Determinations

    A-14.4 Acetylsalicylic acid, salicylic acid, and salicyl amide

    A-41.3 Glycerol in tobacco

    A-78.2 Organic acids in wine

    A-81.2 Oligosaccharides in molasses

    A-83.1 Determination of sucralose and fructose in food and drinks

    A-84.1 Determination of tetrandrin in Stephania tetrandra

    Validated Methods

    We develop and validate reliable HPTLC methods for the identification ofbotanical raw materials and finished products. By following our validatedmethods reproducible results and comparable analyses are achieved which

    guarantee for an unfailing quality control.Currently ten validated methods are available, more are to come. Pleasecontact [email protected] the validated methods or the validation protocol.

    MOA 001 Green teaMOA 002 GinsengMOA 003 EleutheroMOA 004 EchinaceaMOA 005 CimicifugaMOA 006 LicoriceMOA 007 KavaMOA 008 Milk ThistleMOA 009 FeverfewMOA 010 Ginger

    HPTLC Fingerprint analysis

    of Herbals

    Application notes

    All methods and application notes can be found on the Internet under:www.camag.com/applications andwww.camag.com/herbals

    For reliable identification of herbal drugs we offer free of charge a largenumber of approved methods. On two pages each you will find informationregarding sample preparation and chromatographic separation as well asimages of the resulting chromatograms.

    The following applications were recently developed:

    HPTLC Fingerprints for the identification of ...

    F-21 Han fangji (Stephania tetrandra)

    F-22A Red Clover (Trifolium pratense): Flavonoids

    F-22B Red Clover (Trifolium pratense): Formononetin

    F-23 Chinese plants with respect to aristolochic acids

    F-24A Echinacea (E. purpurea, E. pallida, E. angustifolia):Phenylpropanoids

    F-24B Echinacea (E. purpurea, E. pallida, E. angustifolia): Alkylamides

    F-25 Kawa (Piper methysticum)

    F-26A Saw Palmetto (Serenoa repens): Ph.Eur.4

    F-26B Saw Palmetto (Serenoa repens): fatty oils

    F-27 Plantain (Plantago lanceolata)

    F-28 Lime flowers (Tilia sp.)

    F-29A Licorice (Glycyrrhiza sp.): polar compounds

    F-29B Licorice (Glycyrrhiza sp.): lipophilic compounds

    F-30 Eleuthero (Eleutherococcus senticosus)

    F-31 Asian Ginseng (Panax ginseng)

    F-32 American Ginseng (Panax quinquefolium)

  • 5/27/2018 Cat logo CAMAG

    19/2719

    CAMAG has been publishing this unique bulletin on Thin-layer Chromato-graphy publications regularly since 1965. It appears twice a year, usually inMarch and September and is available to CAMAG customers at no charge.The literature abstracts of the current CBS issue can also be accessed onthe internet.

    A CBS abstract contains if quoted in the original publication:

    Name(s) of author(s)

    Address of corresponding author

    Original title, if in one of the common Western hemisphere languages

    English translation of non-English title

    Publication details

    Brief abstract of the TLC related content with particular reference toseparation systems, detection methods, quantification, results, etc.

    Key words.

    The purpose of the CBS is to inform readers about the existence ofpapers in their particular TLC field of interest.Reprints or photocopies of papers abstracted in the CBS are not availablefrom CAMAG.

    CAMAG Bibliography Service

    CBSThe most comprehensive compilation of TLC literature is now available asdatabase. It includes all abstracts published since May 1983 that meansTLC/HPTLC publications since 1982. It is updated after every regular CBSissue. At time of print of this catalog it contains about 8500 abstracts.

    The most recent version of CCBS is available free of charge for downloadfrom our Internet site www.camag.com. Alternatively it can be requestedfrom CAMAG on CD-ROM.

    With the CCBS database you can now carry out your own exhaustiveTLC/HPTLC literature search:

    Enter your search word, e.g. an authors name, a substance, a technique,

    a reagent or a term from amongst the key words of the abstract.

    Start the search routine.

    The abstracts in which the key word occurs appear separately and insequence on the screen together with an indication of the total numberof abstracts in which the search word was found.

    From the result you can print out selected abstracts.

    CUMULATIVE CAMAG

    BIBLIOGRAPHY SERVICE CCBS

  • 5/27/2018 Cat logo CAMAG

    20/27

    CAMAG high performanceinstruments forPlanar Chromatographynot listed in this catalog:

    Sample Application

    Linomat 5

    Automatic TLC Sampler 4 (ATS 4)

    Chromatogram Development

    Automatic Multiple Development (AMD 2)

    Automatic Developing Chamber (ADC 2)

    Evaluation and Documentation

    TLC Scanner 3

    DigiStore

    For detailed information visit

    www.camag.com

    Catalogitems-E-08

    996.2

    335

    Distributor:CAMAG (Switzerland)Sonnenmattstrasse 11CH-4132 Muttenz 1Telephone +41 61 467 34 34

    Fax +41 61 461 07 02E-mail: [email protected]

    www.camag.com

  • 5/27/2018 Cat logo CAMAG

    21/27

    CHROMACIM Distributeur exclusif CAMAG INSTRUMENTATION

    Prix Public 2014

    sige social

    L'Ancienne Eglise

    38340 Pommiers laPlacette

    CHROMACIM SAS

    Centr'Alp Inopolis Bt. A

    170 rue de Chatagnon, 38430 MOIRANS

    Tl. 04 76 31 24 48 - Fax 04 76 32 83 05www.chromacim.com 1

    Rfrences DsignationsPrix h.t.

    en euros

    Page NANOMAT ET DISTRIBUTEUR DE CAPILLAIRES

    Catalogue

    5 022.4735 Nanomat 4 complet, incl. dispenser, holder, magazin, pipettes 1ul 2088,00

    022.7650Distributeur de capillaires complet (porte-capillaire=022.7786 +

    magasin=022.7661+ capillaires 1 L, 5 x 100 =022.7771) 964,00

    022.7655 Distributeur de capillaires, (seul) 451,00

    022.7786 Porte-capillaire universel 240,00

    022.7660 Magasin rechargeable pour 100 capillaires de 0.5 L 271,00

    022.7661 Magasin rechargeable pour 100 capillaires de 1 L 271,00

    022.7662 Magasin rechargeable pour 100 capillaires de 2 L 271,00

    022.7665 Magasin rechargeable pour 100 capillaires de 5 L 271,00

    022.7770 Bote de 5 x 100 capillaires 0.5 L (sur bande adhsive) pour 022.7660 117,00022.7771 Bote de 5 x 100 capillaires 1 L (sur bande adhsive) pour 022.7661 117,00

    022.7772 Bote de 5 x 100 capillaires 2 L (sur bande adhsive) pour 022.7662 117,00

    022.7775 Bote de 5 x 100 capillaires 5 L (sur bande adhsive) pour 022.7665 117,00

    AUTRES TECHNIQUES POUR APPLICATION MANUELLE

    022.7725 Capillaires usage unique de 0.5 L, tube de 100 21,00

    022.7726 Capillaires usage unique de 1 L, tube de 100 21,00

    022.7727 Capillaires usage unique de 2 L, tube de 100 21,00

    022.7729 Capillaires usage unique de 5 L, tube de 100 21,00

    022.7142 Capillaires en verre gradu de 5 L, paquet de 250 70,00

    022.4230 Guide de dpt universel pour plaques 20x20 cm 197,00

  • 5/27/2018 Cat logo CAMAG

    22/27

    CHROMACIM Distributeur exclusif CAMAG INSTRUMENTATION

    Prix Public 2014

    sige social

    L'Ancienne Eglise

    38340 Pommiers laPlacette

    CHROMACIM SAS

    Centr'Alp Inopolis Bt. A

    170 rue de Chatagnon, 38430 MOIRANS

    Tl. 04 76 31 24 48 - Fax 04 76 32 83 05www.chromacim.com 2

    Page

    catalogueRfrences Dsignations

    Prix h.t.

    en euros

    CUVES ET ACCESSOIRES

    6

    022.5256 avec couvercle acier inoxydable 455,00

    022.5255 avec couvercle en verre 418,00

    022.5258 sans couvercle 399,00

    022.5254 avec couvercle acier inoxydable 331,00

    022.5253 avec couvercle en verre 296,00

    022.5251 sans couvercle 275,00

    022.5261 sans couvercle pour ADC 2 291,00

    022.5155 avec couvercle acier inoxydable 209,00

    022.5156 sans couvercle 173,00

    022.5285 20x20 cm avec couvercle en verre 308,00

    022.5280 20x10 cm avec couvercle en verre 231,00

    022.5259 avec couvercle acier inoxydable 409,00

    022.5250 avec couvercle en verre 374,00

    022.5257 sans couvercle 356,00

    022.5150 avec couvercle acier inoxydable 219,00

    022.5151 sans couvercle 184,00

    022.5265 Couvercle en inox pour cuve Camag 20x20 cm ou 20x10 cm 54,00

    022.5102 Couvercle en inox pour cuves 10x10 cm 35,00

    022.5252 Couvercle en verre, pour cuve Camag 20x20 ou 20x10 cm 19,00

    022.5275 pour plaques 20x20 cm avec couvercle en verre 258,00

    022.5270 pour plaques 20x10 cm avec couvercle en verre 229,00

    022.5279 Couvercle de rechange en verre pour cuves "construction lgre" 43,00

    Cuve fond plat "construction lgre"

    Cuve CAMAG double bac, pour plaques 20 x 20 cm

    Cuve CAMAG double bac, pour plaques 10 x 10 cm

    Cuve double bac, construction lgre

    Cuve fond plat, pour plaques 20 x 20 cm

    Cuve CAMAG double bac, pour plaques 20 x 10 cm

    Cuve fond plat, pour plaques 10x10 cm

  • 5/27/2018 Cat logo CAMAG

    23/27

    CHROMACIM Distributeur exclusif CAMAG INSTRUMENTATION

    Prix Public 2014

    sige social

    L'Ancienne Eglise

    38340 Pommiers laPlacette

    CHROMACIM SAS

    Centr'Alp Inopolis Bt. A

    170 rue de Chatagnon, 38430 MOIRANS

    Tl. 04 76 31 24 48 - Fax 04 76 32 83 05www.chromacim.com 3

    Page

    catalogueRfrences Dsignations

    Prix h.t.

    en euros

    7

    022.5300 SmartALERT, systme de surveillance de la migration des plaques 414,00

    022.5244 Feuille de saturation (100 feuilles) 267,00

    CUVES HORIZONTALES

    022.8530 Cuve horizontale pour plaques HPTLC 10x10 cm 1328,00

    022.8535 Cuve horizontale pour plaques HPTLC 20x10 cm 1544,00

    8

    022.8550 Systme Vario HPTLC, complet 2732,00

    022.8555 Cuve Vario HPTLC 1629,00

    022.8556 Fraiseuse pour Vario HPTLC 1190,00

    022.8558 Lames pour fraiseuse 022.8556, paquet de 10 57,00

    REVELATION DES PLAQUES

    9 022.6606 Dispositif de rvlation par immersion III, sans cuve 2837,00

    022.6627 Cuve immersion pour plaques 20x20 cm, avec couvercle 327,00

    022.6628 Cuve immersion pour plaques 20x10 cm, avec couvercle 233,00

    022.6619 Support de rangement pour trois cuves immersion 308,00

    022.6530 Pulvrisateur lectropneumatique complet 1113,00

    022.6535 Ttes de pulvrisation, 5x type A, 1x type B 227,00

    022.6538 Ttes de pulvrisation, 6x type B 269,00

    022.6536 Flacon de 100 ml, paquet de 6 203,00

    022.6537 Flacon de 50 ml, paquet de 6 169,00

    022.6539 Kit de maintenance pour 022.6530 240,00

    10 022.6100 Vaporisateur en verre 188,00

    022.6101 Tte de pulvrisation pour vaporisateur 022.6100 123,00

    022.6102 Flacon pour vaporisateur 022.6100 42,00

    022.6103 Pompe en caoutchouc pour vaporisateur 022.6100 25,00

    022.6230 Hotte de pulvrisation CCM II avec ventilateur et tuyau 1.5 m 4171,00

    022.6232 Hotte de pulvrisation CCM II sans ventilateur (avec tuyau 1.5 m) 3258,00

    022.3306 Plaque chauffante CCM III, 230 V 2479,00

    SYSTEME VARIO POUR HPTLC

    SMARTALERT- FEUILLES DE SATURATION

  • 5/27/2018 Cat logo CAMAG

    24/27

    CHROMACIM Distributeur exclusif CAMAG INSTRUMENTATION

    Prix Public 2014

    sige socialL'Ancienne Eglise38340 Pommiers laPlacette

    CHROMACIM SASCentr'Alp Inopolis Bt. A

    170 rue de Chatagnon, 38430 MOIRANSTl. 04 76 31 24 48 - Fax 04 76 32 83 05

    www.chromacim.com 4

    Page

    catalogueRfrences Dsignations

    Prix h.t.

    en euros

    11 LAMPES UV

    022.9070 Enceinte UV complte (botier 022.9055 & lampes 022.9120) 1556,00022.9055 Botier d'observation, sans lampe UV 778,00022.9120 Lampe UV 254/366 nm, 2 x 8 W 840,00022.9110 Lampe UV 2x254 nm, 2 x 8 W 840,00022.9115 Lampe UV 2x366 nm, 2 x 8 W 840,00022.9145 Support pour lampes UV (de la srie 022.91XX) 142,00022.9146 Adaptateur d'allume-cigare d'alimentation pour lampes UV (de la srie 022.91XX) 83,00

    352.0010 Tube pour UV 254 nm, 8 W 51,00352.0011 Tube pour UV 366 nm, 8 W 53,00

    352.0015 Tube lumire froide, lumire blanche 14,00692.0042 Filtre UV pour lampes UV de la srie 022.91XX 177,00

    12 Plaques HPTLC et TLC MERCK

    034.5631 Gel de silice 60, plaques en verre pour HPTLC 10 x 10 cm,pack of 25 170,00034.5641 Gel de Silice 60, plaques en verre pour HPTLC 20 x 10 cm,pack of 50 360,00034.5628 Gel de silice 60 F254, plaques en verre pour HPTLC 10 x 10 cm,pack of 25 170,00034.5629 Gel de silice 60 F254, plaques en verre pour HPTLC 10 x 10 cm,pack of 10 530,00034.5642 Gel de silice 60 F254, plaques en verre pour HPTLC 20 x 10 cm,pack of 50 400,00034.3724 Plaques HPTLC RP-18 F 254s, 10 x 10 cm, pack of 25 350,00034.4296 Plaques HPTLC 60 RP-18 W 20 x 10 cm,pack of 25 560,00

    034.5498 Plaques HPTLC RP18 F254S 20 x 10 cm ,pack of 25 700,00

    VIALScaps caps Chromacol 500x11PSN(B) TST1 par 500 254,00vials vials Chromacol 500x2RV P926 par 500 122,00

  • 5/27/2018 Cat logo CAMAG

    25/27

    CHROMACIM Distributeur exclusif CAMAG INSTRUMENTATION

    Prix Public 2014

    sige social

    L'Ancienne Eglise

    38340 Pommiers laPlacette

    CHROMACIM SAS

    Centr'Alp Inopolis Bt. A

    170 rue de Chatagnon, 38430 MOIRANS

    Tl. 04 76 31 24 48 - Fax 04 76 32 83 05www.chromacim.com 5

    Page

    catalogueRfrences Dsignations

    Prix h.t.

    en euros

    13 APPAREILS ET MATERIELS POUR FABRICATION DES PLAQUES

    022.1602 Etaleur de plaques, automatique 10070,00

    022.1612 Magasin de plaques supplmentaires pour 022.1602/3 492,00

    022.1251 Etaleur de plaques, manuel 1100,00

    022.1216 Gabarit fixe spcial, deux paisseurs jusqu'au 1 mm 197,00

    022.1217 Gabarit fixe spcial, deux paisseurs plus de 1 mm 197,00

    022.2200 Plaques de verre 20x20 cm, paquet de 10 197,00

    022.2100 Plaques de verre 10x20 cm, paquet de 10 162,00

    022.0260 Ensemble pour fabrication des plaques, avec taleur automatique comprenan 11628,00

    022.1602 Etaleur de plaques, automatique

    3 x 022.2200 Plaques de verre 20x20 cm, paquet de 102 x 022.3250Cassette inox pour plaques CCM

    032.3401 Aluminium oxide CAMAG DSF-0, 1 kg

    032.3562 Cellulose CAMAG DSF-0, 500 g

    033.7730 Gel de Silice MERCK GF254, type 60 1 kg

    022.0265 Ensemble pour fabrication des plaques, avec taleur manuel comprenant : 2344,00

    022.1251 Etaleur de plaques, manuel

    2 x 022.2200 Plaques de verre 20x20 cm, paquet de 10

    022.3250 Cassette inox pour plaques CCM

    032.3401 Aluminium oxide CAMAG DSF-0, 1 kg

    032.3562 Cellulose CAMAG DSF-0, 500 g

    033.7730 Gel de Silice MERCK GF254, Type 60 1 kg

  • 5/27/2018 Cat logo CAMAG

    26/27

    CHROMACIM Distributeur exclusif CAMAG INSTRUMENTATION

    Prix Public 2014

    sige social

    L'Ancienne Eglise

    38340 Pommiers laPlacette

    CHROMACIM SAS

    Centr'Alp Inopolis Bt. A

    170 rue de Chatagnon, 38430 MOIRANS

    Tl. 04 76 31 24 48 - Fax 04 76 32 83 05www.chromacim.com 6

    Page

    catalogueRfrences Dsignations

    Prix h.t.

    en euros

    14 022.4300 SmartCUT, systme de dcoupe de plaques 1035,00

    115.4305 Lame de rechange pour smartCUT 132,00

    022.3200 Ensemble de schage 505,00

    022.3250 Cassette inox pour plaques CCM 509,00

    032.8001 Mlange colorant-test I 100 ml (pour gel de silice) 53,00

    032.8002 Mlange colorant-test II 100 ml (pour alumine) 53,00

    032.8003 Mlange colorant-test III N 10 ml (gel de silice HPTLC) 53,00

    15 Adsorbants en vrac pour la fabrication des plaques NOUS CONSULTER

    16 022.0216 Ensemble pour CCM avec enceinte UV comprenant : 5791,00

    022.4730 NANOMAT 4 (seul)

    022.7650Distributeur de capillaires complet (porte-capillaire 022.7786 + magasin

    022.7661+ 5 x 100 capillaires 1 L 022.7771)

    022.7662 Magasin rechargeable pour 100 capillaires de 2 L

    022.7665 Magasin rechargeable pour 100 capillaires de 5 L

    022.7772 Bote de 5 x 100 capillaires 2 L (sur bande adhsive) pour 022.7662

    022.7775 Bote de 5 x 100 capillaires 5 L (sur bande adhsive) pour 022.7665

    2 x 022.5256 Cuves double bac, 20x20 cm avec couvercle acier inoxydable

    022.5300 SmartALERT

    022.5244 Feuilles de saturation 20x20 cm, (100 feuilles)

    022.6100 Vaporisateur en verre034.5715 Plaques TLC MERCK gel de Silice 60 F254,20X20 cm, paquet de 25,

    032.8001 Mlange de colorant pour test I 100 ml (pour gel de silice)

    022.9070 Enceinte UV complte (botier 022.9055 & lampes 022.9120)

    022.0226 Ensemble HPTLC avec enceinte UV 7087,00

    022.4730 NANOMAT 4 (seul)

    022.7650Distributeur de capillaires complet (porte-capillaire=022.7786 +

    magasin=022.7661 + capillaires 1 L, 5 x 100 =022.7771)

    022.7660 Magasin rechargeable pour 100 capillaires de 0.5 L

    022.7770 Bote de 5 x 100 capillaires 0.5 L (sur bande adhsive) pour 022.7660

    2 x 022.5155 Cuves double bac, 10x10 cm avec couvercle acier inoxydable022.5300 SmartALERT

    022.8530 Cuve Horizontale pour plaques HPTLC 10x10 cm

    022.5244 Feuilles de saturation 20x20 cm, (100 feuilles)

    034.5628 Plaques HPTLC MERCK gel de Silice 60 F254, 10x10 cm, paquet de 25

    032.8003 Mlange de colorant pour test III N 10 ml (gel de silice HPTLC)

    022.9070 Enceinte UV complte (botier 022.9055 & lampes 022.9120)

    17 995.0040 Livre "HPTLC for Analysis of Medicinal Plants" Reich/Schibli 150,00

  • 5/27/2018 Cat logo CAMAG

    27/27

    Sige social

    L'ancienne Eglise

    38340 Pommiers La Placette

    Liste de prix 2014Catalogue de consommable

    Conditions de vente

    1 Les prix sont des prix en euros hors taxes, valables du 01 janvier au 31dcembre 2014.

    2 Les conditions de vente sont les suivantes :

    Envoi standard : un forfait de port et demballage de 25 euros sera facturpour toute commande dun montant infrieur 1000 euros hors taxes. Lefranco de port est offert pour toute commande, au-del dun montant de1000 euros hors taxes. Lemballage et le traitement de commande sontofferts.

    Envoi express : 30 euros (ou plus en fonction de la taille et du poids delenvoi).

    3 Conditions de livraison :

    Larticle est en stockLivraison sous 72 heures en standard rception de commande. Livr soitpar courrier, soit par messagerie.Livraison express du jour au lendemain pour toute commande passe

    avant 15H00.

    Larticle nest pas en stockLivraison sous trois semaines rception de votre commande.

    4 Conditions de rglement :

    Rglement 30 jours net date de facture.

    coordonnes banque guichet compte cl Domiciliation Voreppe

    bancaires 10468 02416 11621300200 06 Banque Rhne Alpes

    CHROMACIM SASCentrAlp Inopolis, Bt. A

    170 rue de Chatagnon

    Tl 04 76 31 24 48 - Fax 04 76 32 83 05www.chromacim.com