catalog atalog fittings & accessories gs & accessories

64
ELECTRICAL PRODUCTS GS & ACCESSORIES ATALOG ob, FITTINGS & ACCESSORIES CATALOG

Upload: others

Post on 04-Oct-2021

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

ELECTRICAL PRODUCTS

GS & ACCESSORIES ATALOG

ob,

FITTINGS & ACCESSORIESCATALOG

Page 2: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

TABLE OF CONTENTS

EMT CONDUIT

1

BX • MC • FLEX

2

NMSE 3

LIQUID-TIGHT

4

RIGID 5

GROUND

6

ACCESSORIES 7

TABLE OF CONTENTS

BX • MC • FLEX

NMSE

LIQUID-TIGHT

RIGID

GROUND

ACCESSORIES

EMT CONDUIT 1

2

3

4

5

6

7

Page 3: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Use: Compression type connectors are used to secure and terminate steel EMT conduit to knock-outs in concrete-tight box, dry or damp location applications.

• Concrete-Tight

Materials: • Zinc Die-Cast

Certification:

® E210498 LR57925 0 Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

EMT Compression Couplings

Use: Compression type couplings are used to join lengths of steel EMT conduit for concrete-tight, dry or damp location applications.

• Concrete-Tight

Materials: • Zinc Die-Cast

Certification:

E210498 LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

EMT Compression Connectors EMT (THINWALL) CONDUIT Catalog UPC No Number 0-87115

Trade Size

Nominal Dimensions A B C

Pcs/ Ctn/Case Case Unit Qty/Qty Wt.

Boxed 8140 08140-2 1/2" 1.19 0.98 0.38 50/500 50 8141 08141-4 3/4" 1.29 1.22 0.40 25/250 35 8142 08142-1 1" 1.48 1.52 0.55 50/200 40 8143 08143-8 1 1/4" 1.70 1.84 0.61 25/100 40 8144 08144-5 1 1/2" 1.86 2.14 0.61 10/40 22 8145 08145-2 2" 2.13 2.54 0.76 5/20 16 8146* 08146-9 2 1/2" 2.62 3.28 1.01 12 13 8147* 08147-6 3" 2.70 3.94 1.04 12 16 8148* 08148-3 3 1/2" 2.80 4.50 1.08 10 18 8149* 08149-0 4" 2.80 4.98 1.08 6 12

*EMT, IMC & RIGID

Boxed w/Insulated Throat 8150 08150-6 1/2" 1.19 0.98 0.38 50/500 50 8151 08151-3 3/4" 1.29 1.22 0.40 25/250 35 8152 08152-0 1" 1.48 1.52 0.55 50/200 40 8153 08153-7 1 1/4" 1.70 1.84 0.61 25/100 40 8154 08154-4 1 1/2" 1.86 2.14 0.61 10/40 22 8155 08155-1 2" 2.13 2.58 0.76 5/20 16 8156* 08156-8 2 1/2" 2.62 3.28 1.01 12 13 8157* 08157-5 3" 2.70 3.94 1.04 12 16 8158* 08158-2 3 1/2" 2.80 4.50 1.08 10 18 8159* 08159-9

* EMT, IMC & RIGID

Boxed / Raintight

4" 2.80 4.98 1.08 6 12

8150-RT 08173-5 1/2" 1.19 0.98 0.38 50/500 60 8151-RT 08174-2 3/4" 1.29 1.22 0.40 25/250 43 8152-RT 08175-9 1" 1.48 1.52 0.55 10/100 25

Catalog

Number UPC No 0-87115

Trade Size

Nominal Dimensions Pcs/ A B C Unit

Ctn/Case Case

Qty/Qty Wt.

Boxed 8130 08013-8 1/2" 1.70 0.98 0.73 50/500 60 8131 08131-5 3/4" 1.78 1.22 0.94 25/250 48 8132 08132-2 1" 1.81 1.52 1.18 10/100 28 8133 08133-9 1 1/4" 2.12 1.84 1.52 10/40 17.6 8134 08134-6 1 1/2" 2.42 2.14 1.76 10/40 28.2 8135 08135-8 2" 2.47 2.58 2.23 5/20 18.1 8136* 08136-5 21/2" 3.27 3.28 2.90 12 16 8137* 08137-2 3" 3.35 3.94 3.53 12 21 8138* 08138-9 31/2" 3.50 4.50 4.00 10 22 8139* 08139-6

* EMT, IMC & RIGID

Boxed / Raintight

4" 3.65 4.98 4.50 6 15

8130-RT 08170-4 1/2" 1.19 0.98 0.38 50/500 35 8131-RT 08171-6 3/4" 1.29 1.22 0.40 25/250 25 8132-RT 08172-8 1" 1.48 1.52 0.55 50/200 28

T'ECICJICC1 BWF. www.teddicobwf.com Teddico/BWF Pittsburgh, Pa. 15205

Use:Compression type connectors are used to secure

and terminate steel EMT conduit to knock-outs in

concrete-tight box, dry or damp location

applications.

• Concrete-Tight

Materials:• Zinc Die-Cast

Certification:E210498 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 348

EMT Compression Connectors EMT (THINWALL) CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8140 08140-2 1/2" 1.19 0.98 0.38 - 50/500 50

8141 08141-4 3/4" 1.29 1.22 0.40 - 25/250 35

8142 08142-1 1" 1.48 1.52 0.55 - 50/200 40

8143 08143-8 1 1/4" 1.70 1.84 0.61 - 25/100 40

8144 08144-5 1 1/2" 1.86 2.14 0.61 - 10/40 22

8145 08145-2 2" 2.13 2.54 0.76 - 5/20 16

8146* 08146-9 2 1/2" 2.62 3.28 1.01 - 12 13

8147* 08147-6 3" 2.70 3.94 1.04 - 12 16

8148* 08148-3 3 1/2" 2.80 4.50 1.08 - 10 18

8149* 08149-0 4" 2.80 4.98 1.08 - 6 12

Boxed w/Insulated Throat8150 08150-6 1/2" 1.19 0.98 0.38 - 50/500 50

8151 08151-3 3/4" 1.29 1.22 0.40 - 25/250 35

8152 08152-0 1" 1.48 1.52 0.55 - 50/200 40

8153 08153-7 1 1/4" 1.70 1.84 0.61 - 25/100 40

8154 08154-4 1 1/2" 1.86 2.14 0.61 - 10/40 22

8155 08155-1 2" 2.13 2.58 0.76 - 5/20 16

8156* 08156-8 2 1/2" 2.62 3.28 1.01 - 12 13

8157* 08157-5 3" 2.70 3.94 1.04 - 12 16

8158* 08158-2 3 1/2" 2.80 4.50 1.08 - 10 18

8159* 08159-9 4" 2.80 4.98 1.08 - 6 12

A

CB

Boxed / Raintight8150-RT 08173-5 1/2" 1.19 0.98 0.38 - 50/500 60

8151-RT 08174-2 3/4" 1.29 1.22 0.40 - 25/250 43

8152-RT 08175-9 1" 1.48 1.52 0.55 - 10/100 25

Use:Compression type couplings are used to join

lengths of steel EMT conduit for concrete-tight, dry

or damp location applications.

• Concrete-Tight

Materials:• Zinc Die-Cast

Certification:E210498 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 348

EMT Compression Couplings

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8130 08013-8 1/2" 1.70 0.98 0.73 - 50/500 60

8131 08131-5 3/4" 1.78 1.22 0.94 - 25/250 48

8132 08132-2 1" 1.81 1.52 1.18 - 10/100 28

8133 08133-9 1 1/4" 2.12 1.84 1.52 - 10/40 17.6

8134 08134-6 1 1/2" 2.42 2.14 1.76 - 10/40 28.2

8135 08135-8 2" 2.47 2.58 2.23 - 5/20 18.1

8136* 08136-5 2 1/2" 3.27 3.28 2.90 - 12 16

8137* 08137-2 3" 3.35 3.94 3.53 - 12 21

8138* 08138-9 3 1/2" 3.50 4.50 4.00 - 10 22

8139* 08139-6 4" 3.65 4.98 4.50 - 6 15

Boxed / Raintight8130-RT 08170-4 1/2" 1.19 0.98 0.38 - 50/500 35

8131-RT 08171-6 3/4" 1.29 1.22 0.40 - 25/250 25

8132-RT 08172-8 1" 1.48 1.52 0.55 - 50/200 28

EM

T (

TH

INW

ALL

) C

ON

DU

IT

Teddico/BWF Pittsburgh, Pa. 15205

*EMT, IMC & RIGID

* EMT, IMC & RIGID

* EMT, IMC & RIGID

1-1 www.teddicobwf.com

A

C

B

Page 4: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

EMT Set Screw Connectors EMT (THINWALL) CONDUIT Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Use: Set screw type connectors are used to secure and terminate steel EMT conduit to knock-outs in concrete-tight box or dry location applications.

• Concrete-Tight when taped . 1 1-4"-4" Double Set Screw

Boxed 8100 08100-1 1/2" 1.14 0.38 0.72 8101 08101-8 3/4" 1.40 0.46 0.94 8102 08102-5 1" 1.55 1.00 1.18 8103 08103-2 1 1/4" 1.96 0.62 1.53 8104 08104-9 1 1/2" 2.20 0.70 1.77 8105 08105-6 2" 2.50 0.75 2.23 8106* 70205-0 2 1/2" 3.00 1.00 2.89 8107* 70210-4 3" 3.38 3.93 3.54 8108* 08108-7 3 1/2" 3.56 4.45 4.06 8109* 70220-3 4" 3.75 1.02 4.53

*EMT, IMC & RIGID

50/500 35 25/250 25 50/200 30 25/100 32 10/40 16 5/20 11 12 10 12 12 10 13 6 9

Materials: • Zinc Die-Cast

Boxed w/ Insulated Throat

Certification: 8110 08110-0 1/2" 1.14 0.38 0.72 50/500 35 0 E210498 6. LR57925 8111 08111-7 3/4" 1.40 0.46 0.94 25/250 25

8112 08112-4 1" 1.55 1.00 1.18 50/200 30 8113 08113-1 11/4" 1.96 0.62 1.53 25/100 32 8114 08114-8 1 1/2" 2.20 0.70 1.77 10/40 16 8115 08115-5 2" 2.50 0.75 2.23 5/20 11 8116* 08116-2 21/2" 3.00 1.00 2.89 12 10 8117* 08117-9 3" 3.38 3.93 3.54 12 12 8118* 08118-6 3 1/2" 3.56 4.45 4.06 10 13 8119* 08119-3 4" 3.75 1.02 4.53 6 9

*EMT, IMC & RIGID

EMT Set Screw Couplings

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

Set screw type couplings are used to join lengths of steel EMT conduit for concrete-tight or dry location applications.

• Concrete-Tight when taped

• 1 1-4"-4" Double Set Screw Materials: • Zinc Die-Cast

Boxed 8120 08120-9 1/2" 1.50 0.93 0.73 8121 08121-6 3/4" 1.87 1.14 0.95 8122 08122-3 1" 2.00 1.41 1.19 8123 08123-0 1 1/4" 2.50 1.83 1.53 8124 08124-7 1-1/2" 2.87 2.06 1.77 8125 08125-4 2" 3.44 2.53 2.23 8126* 70305-7 2-1/2" 4.00 3.30 2.90 8127* 70310-1 3" 4.49 3.94 3.54 8128* 08128-5 3 1/2" 4.92 4.45 4.05 8129* 70320-0 4" 5.23 4.96 4.55

*EMT, IMC & RIGID

50/500 35 25/250 25 50/200 28 25/100 32 10/40 24 5/20 11 12 9 12 12 10 12 6 10

Certification:

E210498 LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

www.teddicobwf.com Teddico/BWF Pittsburgh, Pa. 15205 BWF.

Use:Set screw type connectors are used to secure and

terminate steel EMT conduit to knock-outs in

concrete-tight box or dry location applications.

• Concrete-Tight when taped

• 1 1-4"-4" Double Set Screw

Materials:• Zinc Die-Cast

Certification:E210498 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 348

EMT Set Screw Connectors EMT (THINWALL) CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8100 08100-1 1/2" 1.14 0.38 0.72 - 50/500 35

8101 08101-8 3/4" 1.40 0.46 0.94 - 25/250 25

8102 08102-5 1" 1.55 1.00 1.18 - 50/200 30

8104 08104-9 1 1/2" 2.20 0.70 1.77 - 10/40 16

8105 08105-6 2" 2.50 0.75 2.23 - 5/20 11

8106* 70205-0 2 1/2" 3.00 1.00 2.89 - 12 10

8107* 70210-4 3" 3.38 3.93 3.54 - 12 12

8108* 08108-7 3 1/2" 3.56 4.45 4.06 - 10 13

8109* 70220-3 4" 3.75 1.02 4.53 - 6 9

Boxed w/ Insulated Throat

8110 08110-0 1/2" 1.14 0.38 0.72 - 50/500 35

8111 08111-7 3/4" 1.40 0.46 0.94 - 25/250 25

8112 08112-4 1" 1.55 1.00 1.18 - 50/200 30

8113 08113-1 1 1/4" 1.96 0.62 1.53 - 25/100 32

8114 08114-8 1 1/2" 2.20 0.70 1.77 - 10/40 16

8115 08115-5 2" 2.50 0.75 2.23 - 5/20 11

8116* 08116-2 2 1/2" 3.00 1.00 2.89 - 12 10

8117* 08117-9 3" 3.38 3.93 3.54 - 12 12

8118* 08118-6 3 1/2" 3.56 4.45 4.06 - 10 13

8119* 08119-3 4" 3.75 1.02 4.53 - 6 9

B

A

C

Use:Set screw type couplings are used to join lengths

of steel EMT conduit for concrete-tight or dry

location applications.

• Concrete-Tight when taped

• 1 1-4"-4" Double Set Screw

Materials:• Zinc Die-Cast

Certification:E210498 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 348

EMT Set Screw Couplings

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8120 08120-9 1/2" 1.50 0.93 0.73 - 50/500 35

8121 08121-6 3/4" 1.87 1.14 0.95 - 25/250 25

8122 08122-3 1" 2.00 1.41 1.19 - 50/200 28

8123 08123-0 1 1/4" 2.50 1.83 1.53 - 25/100 32

8124 08124-7 1-1/2" 2.87 2.06 1.77 - 10/40 24

8125 08125-4 2" 3.44 2.53 2.23 - 5/20 11

8126* 70305-7 2-1/2" 4.00 3.30 2.90 - 12 9

8127* 70310-1 3" 4.49 3.94 3.54 - 12 12

8128* 08128-5 3 1/2" 4.92 4.45 4.05 - 10 12

8129* 70320-0 4" 5.23 4.96 4.55 - 6 10

AC

B

Teddico/BWF Pittsburgh, Pa. 15205

8103 08103-2 1 1/4" 1.96 0.62 1.53 - 25/100 32

EM

T (T

HIN

WA

LL) CO

ND

UIT

1-2www.teddicobwf.com

*EMT, IMC & RIGID

*EMT, IMC & RIGID

*EMT, IMC & RIGID

Page 5: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

EMT Compression Connectors EMT (THINWALL) CONDUIT

EMT Compression Couplings

ed_rieifr of

Catalog Number

UPC No 0-87115

Trade Size

Case Qty

Case Wt.

Boxed

9140 09140-6 1/2" 50/250 30

9141 09141-3 3/4" 25/125 21

9142 09142-0 1" 15/75 19 9143 09143-7 1-1/4" 20 10 9144 09144-4 1-1/2" 5 3 9145 09145-1 2" 10 10 R146* 09146-8 2-1/2" 8 13

9147* 09147-5 3" 5 13 9148* 09148-2 3-1/2" 5 13 9149* 09149-9 4" 5 18

* EMT & RIGID

Catalog Number

UPC No 0-87115

Trade Size

Case

Qty

Case Wt.

Boxed w/Insulated Throat

9150 09150-5 1/2" 50/250 30 9151 09151-2 3/4" 25/125 21 9152 09152-9 1" 15/75 19 9153 09153-6 1-1/4" 20 10 9154 09154-3 1-1/2" 5 3 9155 09155-0 2" 10 10 9156* 09156-7 2-1/2" 8 13 9157* 09157-4 3" 5 13 9158* 09158-1 3-1/2" 5 13 9159* 09159-8 4" 5 18

* EMT & RIGID

Catalog Number

UPC No 0-87115

Trade Size

Case

Qty

Case Wt.

Boxed

9130 09130-7 1/2" 50/250 32 9131 09131-4 3/4" 25/125 20 9132 09132-1 1" 15/75 23 9133 09133-8 1-1/4" 20 12 9134 09134-5 1-1/2" 5 4 9135 09135-2 2" 10 12 9136* 09136-9 2-1/2" 8 19 9137* 09137-6 3" 5 16 9138* 09138-3 3-1/2" 5 18 9139* 09139-0 4" 5 25

* EMT & RIGID

Use: Compression type connectors are used to secure and terminate steel EMT conduit to knock-outs in concrete-tight box, dry or damp location applications.

• Concrete-Tight

Materials: • Steel

Certification:

® E210498 LR57925 El 55411 El 84480

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

Compression type couplings are used to join lengths of steel EMT conduit for concrete-tight, dry or damp location applications.

• Concrete-Tight

Materials: • Steel

Certification:

® E210498 LR57925 E155411 El 84480

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

BWF. www.teddicobwf.com Teddico/BWF Pittsburgh, Pa. 15205

Use:Compression type connectors are used to secure

and terminate steel EMT conduit to knock-outs in

concrete-tight box, dry or damp location

applications.

• Concrete-Tight

Materials:• Steel

Certification:E210498 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 348

EMT Compression Connectors EMT (THINWALL) CONDUITCatalog UPC No Trade Case Case

Number 0-87115 Size Qty Wt.

Boxed

Use:Compression type couplings are used to join

lengths of steel EMT conduit for concrete-tight, dry

or damp location applications.

• Concrete-Tight

Materials:• Steel

Certification:E210498 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 348

EMT Compression Couplings

9140914191429143914491459146*9147*9148*9149*

09140-609141-309142-009143-709144-409145-109146-809147-509148-209149-9

1/2"

3/4"1"1-1/4"

1-1/2"2"

2-1/2"3"3-1/2"4"

50/25025/12515/75205108555

EM

T (

TH

INW

ALL

) C

ON

DU

IT

Teddico/BWF Pittsburgh, Pa. 15205

Catalog UPC No Trade Case Case

Number 0-87115 Size Qty Wt.

Boxed w/Insulated Throat9150915191529153915491559156*9157*9158*9159*

09150-509151-209152-909153-609154-309155-009156-709157-409158-109159-8

1/2"

3/4"1"1-1/4"

1-1/2"2"

2-1/2"3"3-1/2"4"

50/25025/12515/75205108555

3021191031013131318

3021191031013131318

* EMT & RIGID

* EMT & RIGID

Catalog UPC No Trade Case Case

Number 0-87115 Size Qty Wt.

Boxed9130913191329133913491359136*9137*9138*9139*

09130-709131-409132-109133-809134-509135-209136-909137-609138-309139-0

1/2"

3/4"1"1-1/4"

1-1/2"2"

2-1/2"3"3-1/2"4"

50/25025/12515/75205108555

3220231241219161825

* EMT & RIGID

1-3 www.teddicobwf.com

E155411

E184480

E155411

E184480

Page 6: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

UPC No 0-87115

Trade Case Case Size Qty Wt.

Catalog Number

1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 3-1/2" 4"

09100-0 09101-7 09102-4 09103-1 09104-8 09105-5 09106-2 09107-5 09108-6 09109-3

50/250 25 25/125 14 20/100 23 5/25 10 10 6 10 8 8 11 5 9 5 13 5 14

Catalog Number

UPC No 0-87115

EMT Set Screw Connectors EMT (THINWALL) CONDUIT

Boxed

Set screw type connectors are used to secure and terminate steel EMT conduit to knock-outs in concrete-tight box or dry location applications.

• Concrete-Tight when taped

• 1 1-4"-4" Double Set Screw

Materials:

• Steel Certification:

0 E210498® LR57925 E155411 El 84480

9100 9101 9102 9103 91n4 9105 9106* 9107* 9108* 9109* *EMT & RIGID

Catalog Number

UPC No 0-87115

Trade Case Case Size Qty Wt.

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 3-1/2" 4"

Boxed w/Insulated Throat

9110 09110-9

9111 09111-6

9112 09112-3 9113 09113-0 9114 09114-7 9115 09115-4 9116* 09116-1

9117* 09117-8 9118* 09118-5 9119* 09119-2 *EMT & RIGID

50/250 25 25/125 14 20/100 23 5/25 10 10 6 10 8 8 11 5 9 5 13 5 14

EMT Set Screw Couplings

EMT (THINWALL) CONDUIT

Trade Case Case Size Qty Wt.

Set screw type couplings are used to join lengths of steel EMT conduit for concrete-tight or dry location applications.

• Concrete-Tight when taped

• 1 1-4"-4" Double Set Screw

Materials: • Steel Certification:

E210498 e LR57925 E155411 El 84480

Boxed

9120 9121 9122 9123 9124 9125 R126* 9127* 9128* 9129*

* EMT & RIGID

09120-8 09121-5 09122-2 09123-9 09124-6 09125-3 09126-0 09127-7 09128-4 09129-1

1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 3-1/2" 4"

50/250 25 25/125 18 10/100 24 5/25 11 10 4 10 9 8 13 5 11 5 13 5 14

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

TEDIDICCD BWF ELECTRICAL PRODUCTS W

www.teddicobwf.com Teddico/BWF Pittsburgh, Pa. 15205

Use:Set screw type connectors are used to secure and

terminate steel EMT conduit to knock-outs in

concrete-tight box or dry location applications.

• Concrete-Tight when taped

• 1 1-4"-4" Double Set Screw

Materials:• Steel

Certification:E210498 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 348

EMT Set Screw Connectors EMT (THINWALL) CONDUIT

Catalog UPC No Trade Case Case

Number 0-87115 Size Qty Wt.

Boxed9100910191029103910491059106*9107*9108*9109*

09100-009101-709102-409103-109104-809105-509106-209107-509108-609109-3

1/2"

3/4"1"1-1/4"

1-1/2"2"

2-1/2"3"3-1/2"4"

50/25025/12520/1005/2510108555

Catalog UPC No Trade Case Case

Number 0-87115 Size Qty Wt.

Boxed w/Insulated Throat9110911191129113911491159116*9117*9118*9119*

09110-909111-609112-309113-009114-709115-409116-109117-809118-509119-2

1/2"

3/4"1"1-1/4"

1-1/2"2"

2-1/2"3"3-1/2"4"

50/25025/12520/1005/2510108555

25142310681191314

25142310681191314

*EMT & RIGID

*EMT & RIGID

Use:Set screw type couplings are used to join lengths

of steel EMT conduit for concrete-tight or dry

location applications.

• Concrete-Tight when taped

• 1 1-4"-4" Double Set Screw

Materials:• Steel

Certification:E210498 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 348

EMT Set Screw Couplings

EMT (THINWALL) CONDUIT

Teddico/BWF Pittsburgh, Pa. 15205

EM

T (

TH

INW

ALL

) C

ON

DU

IT

Catalog UPC No Trade Case Case

Number 0-87115 Size Qty Wt.

Boxed9120912191229123912491259126*9127*9128*9129*

09120-809121-509122-209123-909124-609125-309126-009127-709128-409129-1

1/2"

3/4"1"1-1/4"

1-1/2"2"

2-1/2"3"3-1/2"4"

50/25025/12510/1005/2510108555

251824114913111314

* EMT & RIGID

1-4www.teddicobwf.com

E155411

E184480

E155411

E184480

Page 7: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Use: Compression type couplings are used to join lengths of steel EMT conduit for raintight applications • Raintight Materials: • Steel

Raintight Steel Compression Connectors EMT (THINWALL) CONDUIT

riliplik ./

(

Catalog Number

UPC No 0-87115

Trade Size

Case Qty

Case Wt.

Boxed

9600 09600-5 1/2" 25/250 26.5

9601 09601-2 3/4" 25/250 42.5

9602 09602-9 1" 10/100 22.7 9603 09603-6 1-1/4" 25 10.2 9604 09604-3 1-1/2" 20 10 9605 09605-0 2" 15 10

Fffin6 09606-7 2-1/2" 12 21.2

9607 09607-4 3" 6 14.1 9608 09608-1 3-1/2" 5 14.4 9609 09609-8 4" 3 10.3

Use: Compression type connectors are used to secure and terminate steel EMT conduit to knock-outs in raintight applications.

• Raintight

Materials:

jLlu

t TH

I NW

AL

L I

siei • Steel

Certification:

Ous E200730 Catalog UPC No Trade Case Case

Standards: Number 0-87115 Size Qty Wt. UL 514B NEMA FB-1 Boxed w/Insulated Throat

9610 09610-4 1/2" 25/250 26.5 9611 09611-1 3/4" 25/250 42.5 9612 09612-8 1" 10/100 22.7 9613 09613-5 1-1/4" 25 10.2 9614 09614-2 1-1/2" 20 10 9615 09615-9 2" 15 10 9616 09616-6 2-1/2" 12 21.2 9617 09617-3 3" 6 14.1 9618 09618-0 3-1/2" 5 14.4 9619 09619-7 4" 3 10.3

Raintight Steel Compression Couplings

Catalog Number

UPC No 0-87115

Trade Size

Case Qty

Case Wt.

Boxed

9620 09620-3 1/2" 25/250 35 9621 09621-0 3/4" 25/250 53.3 9622 09622-7 1" 50/200 28 9623 09623-4 1-1/4" 25 12.1 9624 09624-1 1-1/2" 20 11.9 9625 09625-8 2" 15 11.8 9626 09626-5 2-1/2" 12 24.7 9627 09627-2 3" 6 15.8 9628 09628-9 3-1/2" 5 15.5 9629 09629-6 4" 3 11.8 Certification:

60, E200730

Standards: UL 514B NEMA FB-1

TE131311013 BWF. www.teddicobwf.com Teddico/BWF Pittsburgh, Pa. 15205

ELECTRIC...L. ■ .-1(7)1.30C I

Use:Compression type connectors are used to secure

and terminate steel EMT conduit to knock-outs in

raintight applications.

• Raintight

Materials:• Steel

Certification:E200730

Standards:UL 514B

NEMA FB-1

Steel Compression ConnectorsCatalog UPC No Trade Case Case

Number 0-87115 Size Qty Wt.

Boxed

Use:Compression type couplings are used to join

lengths of steel EMT conduit for raintight applications

• Raintight

Materials:• Steel

Certification:E200730

Standards:UL 514B

NEMA FB-1

Steel Compression Couplings

9600960196029603960496059606960796089609

09600-509601-209602-909603-609604-309605-009606-709607-409608-109609-8

1/2"

3/4"1"1-1/4"

1-1/2"2"

2-1/2"3"3-1/2"4"

25/25025/25010/10025201512653

EM

T (

TH

INW

ALL

) C

ON

DU

IT

Teddico/BWF Pittsburgh, Pa. 15205

Catalog UPC No Trade Case Case

Number 0-87115 Size Qty Wt.

Boxed w/Insulated Throat9610961196129613961496159616961796189619

09610-409611-109612-809613-509614-209615-909616-609617-309618-009619-7

1/2"

3/4"1"1-1/4"

1-1/2"2"

2-1/2"3"3-1/2"4"

25/25025/25010/10025201512653

26.542.522.710.2101021.214.114.410.3

26.542.522.710.2101021.214.114.410.3

Catalog UPC No Trade Case Case

Number 0-87115 Size Qty Wt.

Boxed9620962196229623962496259626962796289629

09620-309621-009622-709623-409624-109625-809626-509627-209628-909629-6

1/2"

3/4"1"1-1/4"

1-1/2"2"2-1/2"

3"3-1/2"4"

25/25025/25050/20025201512653

3553.32812.111.911.824.715.815.511.8

Raintigh t

Raintigh t

1-5 www.teddicobwf.com

EMT (THINWALL) CONDUIT

Page 8: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

25/250 37.1 20/200 54.0

LR57925

LR57925

90° EMT Connectors EMT (THINWALL) CONDUIT Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed 8203 08203-9 1/2" 1.35 0.98 0.51 8204 08204-6 3/4" 1.47 0.42 0.52

Use: 90° connectors are used to terminate steel EMT conduit to an unthreaded box or enclosure in dry or damp locations where a 90° bend is required. • Compression Type

• Concrete -Tight

• Rain-Tight

Materials: • Zinc Die-Cast

Certification:

E155411

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

90° EMT Connectors EMT (THINWALL) CONDUIT Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-31857 Size A B C Unit Qty/Qty Wt.

Boxed 8358 18358-3 1/2" 1.43 1.19 0.48 8359 18359-0 3/4" 1.47 1.42 0.54

90° connectors are used to terminate steel EMT conduit to an unthreaded box or enclosure in dry locations where a 90° bend is required.

• Set Screw Type

Materials: • Zinc Die-Cast

20/200 29.6 20/200 41.6

Certification:

E155411

• Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

TECICIIICCD BWF ELECTRICAL PRODUCTS W

www.tedd i co bwf.co m Teddico/BWF Pittsburgh, Pa. 15205

EM

T (T

HIN

WA

LL) CO

ND

UIT

Teddico/BWF Pittsburgh, Pa. 15205

Use:90° connectors are used to terminate steel EMTconduit to an unthreaded box or enclosure in dryor damp locations where a 90° bend is required.• Compression Type

• Concrete -Tight

• Rain-Tight

Materials:• Zinc Die-Cast

Certification:E155411 LR57925

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

90° EMT Connectors EMT (THINWALL) CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8203 08203-9 1/2" 1.35 0.98 0.51 - 25/250 37.1

8204 08204-6 3/4" 1.47 0.42 0.52 - 20/200 54.0A

B C

Use:90° connectors are used to terminate steel EMT

conduit to an unthreaded box or enclosure in dry

locations where a 90° bend is required.

• Set Screw Type

Materials:• Zinc Die-Cast

90° EMT Connectors EMT (THINWALL) CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-31857 Size A B C Unit Qty/Qty Wt.

Boxed8358 18358-3 1/2" 1.43 1.19 0.48 - 20/200 29.6

8359 18359-0 3/4" 1.47 1.42 0.54 - 20/200 41.6

A

B

C

1-6www.teddicobwf.com

Certification:E155411 LR57925

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

Page 9: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

A

T (

TH

INW

AL

L)

CO

ND

UIT

EMT To Box Offset Connectors EMT (THINWALL) CONDUIT Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed 8300 08300-5 1/2" 2.09 0.92 0.41 10/100 10.6 8301 08301-2 3/4" 3.01 1.12 0.46 10/100 18.3

Set screw type offset connectors are used to make a slight adjustment in terminating the end of a run of steel EMT conduit to an enclosure or box in dry locations. • Set Screw Type

• Concrete-Tight when taped

Materials: • Zinc Die-Cast Certification:

E210498 LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

EMT To Box Offset Connectors EMT (THINWALL) CONDUIT Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-31857 Size A B C Unit Qty/Qty Wt.

Boxed 8308 08308-1 1/2" 1.87 0.98 0.40 10/100 27.9 8309 08309-8 3/4" 2.63 1.22 0.46 10/100 22.2

Use: Compression type offset connectors are used to make a slight adjustment in terminating the end of a run of steel EMT Conduit to an enclosure or box in dry or damp locations. • Compression Type

• Concrete -Tight

Materials: • Zinc Die-Cast Certification:

11::) E210498 LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

BWF. www.tedd i co bwf.co m Teddico/BWF Pittsburgh, Pa. 15205

Use:Compression type offset connectors are used tomake a slight adjustment in terminating the end ofa run of steel EMT Conduit to an enclosure or boxin dry or damp locations. • Compression Type

• Concrete -Tight

Materials:• Zinc Die-Cast

Certification:E210498 LR57925

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

EMT To Box Offset Connectors EMT (THINWALL) CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-31857 Size A B C Unit Qty/Qty Wt.

Boxed8308 08308-1 1/2" 1.87 0.98 0.40 - 10/100 27.9

8309 08309-8 3/4" 2.63 1.22 0.46 - 10/100 22.2A

C

B

Use:Set screw type offset connectors are used tomake a slight adjustment in terminating the end ofa run of steel EMT conduit to an enclosure or boxin dry locations.• Set Screw Type

• Concrete-Tight when taped

Materials:• Zinc Die-Cast

Certification:E210498 LR57925

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed

8300 08300-5 1/2" 2.09 0.92 0.41 - 10/100 10.6

8301 08301-2 3/4" 3.01 1.12 0.46 - 10/100 18.3A

C

B

EM

T (

TH

INW

ALL

) C

ON

DU

IT

Teddico/BWF Pittsburgh, Pa. 152051-7 www.teddicobwf.com

EMT (THINW ALL) CONDUITEMT To Box Offset Connectors

Page 10: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

EMT (THINWALL) CONDUIT Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

EMT To EMT Pull Elbows

ca

Use: Pull elbows are used to facilitate pulling conductors through a 90° bend in a run of steel EMT Conduit. The removable cover gives ample access so that wire pulling can be achieved without any obstruction. • Set Screw Type

• Removable Aluminum Cover

Materials: • Zinc Die-Cast

EMT To Box Pull Elbows

Boxed 8340 8341 8342 8343

Boxed w/ Gasket

8340-G 08415-6 1/2" 1.31 1.02 0.96 - 10/100 20.1

8341-G 08416-3 3/4" 1.37 1.28 1.18 - 5/50 14.3

8342-G 08357-9 1" 1.95 1.55 1.52 - 10 6.1

8343-G 08358-6 1 1/4" 2.32 1.92 1.88 - 5 4.8

EMT (THINWALL) CONDUIT

08340-1 1/2" 1.31 1.02 0.96

08341-8 3/4" 1.37 1.28 1.18

08342-5 1" 1.95 1.55 1.52

08343-2 1 1/4" 2.32 1.92 1.88

10/100 19.4 5/50 15.0 10 6.1 5 4.7

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed 8330 08330-2 1/2" 1.31 1.02 0.96 8331 08331-9 3/4" 1.37 1.28 1.17

10/100 20.1 5/50 16.7

Use: Pull elbows are used to facilitate pulling conductors through a 90° bend in a run of steel EMT Conduit. The removable cover gives ample access so that wire pulling can be achieved without any obstruction. • Set Screw Type

• Removable Aluminum Cover

Materials: • Zinc Die-Cast Certification:

0 E155411 LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

Inside Corner Pull Elbows

Boxed w/ Gasket

8330-G 08400-2 1/2" 1.31 1.02 0.96 10/100 21.6

8331-G 08401-9 3/4" 1.37 1.28 1.17 5/50 15.9

EMT (THINWALL) CONDUIT Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed 8215 08215-2 1/2" 1.80 0.93 0.72 10 10/100 20.9 8216 08216-9 3/4" 2.00 1.13 0.94 5 5/50 13.8

Use: Inside corner pull elbows are used to facilitate pulling conductors through a 90° bend in a run of steel EMT conduit where it is essential to make tight turns within limited available space. • Set Screw Type

• Concrete-Tight when taped

Materials: • Zinc Die-Cast Certification:

® E155411•LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ E TECICIIICCD BWF ELECTRICAL PRODUCTS W

www.tedd i co bwf.co m

Use:Pull elbows are used to facilitate pullingconductors through a 90° bend in a run of steelEMT Conduit. The removable cover gives ampleaccess so that wire pulling can be achievedwithout any obstruction.• Set Screw Type

• Removable Aluminum Cover

Materials:• Zinc Die-Cast

EMT To EMT Pull Elbows EMT (THINWALL) CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8340 08340-1 1/2" 1.31 1.02 0.96 - 10/100 19.4

8341 08341-8 3/4" 1.37 1.28 1.18 - 5/50 15.0

8342 08342-5 1" 1.95 1.55 1.52 - 10 6.1

8343 08343-2 1 1/4" 2.32 1.92 1.88 - 5 4.7

Boxed w/ Gasket8340-G 08415-6 1/2" 1.31 1.02 0.96 - 10/100 20.1

8341-G 08416-3 3/4" 1.37 1.28 1.18 - 5/50 14.3

8342-G 08357-9 1" 1.95 1.55 1.52 - 10 6.1

8343-G 08358-6 1 1/4" 2.32 1.92 1.88 - 5 4.8

A

C

B

Use:Pull elbows are used to facilitate pullingconductors through a 90° bend in a run of steelEMT Conduit. The removable cover gives ampleaccess so that wire pulling can be achievedwithout any obstruction.• Set Screw Type

• Removable Aluminum Cover

Materials:• Zinc Die-Cast

Certification:E155411 LR57925

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

EMT To Box Pull Elbows EMT (THINWALL) CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8330 08330-2 1/2" 1.31 1.02 0.96 - 10/100 20.1

8331 08331-9 3/4" 1.37 1.28 1.17 - 5/50 16.7

Boxed w/ Gasket8330-G 08400-2 1/2" 1.31 1.02 0.96 - 10/100 21.6

8331-G 08401-9 3/4" 1.37 1.28 1.17 - 5/50 15.9

A

C

B

Use:Inside corner pull elbows are used to facilitate

pulling conductors through a 90° bend in a run of

steel EMT conduit where it is essential to make

tight turns within limited available space.

• Set Screw Type

• Concrete-Tight when taped

Materials:• Zinc Die-Cast

Certification:E155411 LR57925

Standards:UL 514BCSA C22.2 No. 18NEMA FB-1NEC Article 348

Inside Corner Pull Elbows EMT (THINWALL) CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8215 08215-2 1/2" 1.80 0.93 0.72 10 10/100 20.9

8216 08216-9 3/4" 2.00 1.13 0.94 5 5/50 13.8

A

CB

EM

T (T

HIN

WA

LL) CO

ND

UIT

Teddico/BWF Pittsburgh, Pa. 15205 1-8www.teddicobwf.com

Page 11: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

EMT One Hole Straps

Use One hole straps are used for providing support for steel EMT Conduit as required by the National Electrical Code. • Click-On Type

Materials: • Stamped Steel Finish: • Zinc Plated

EMT (THINW ALL) CONDUIT Catalog Number

UPC No

0-87115

Trade Size

Nominal Dimensions Pcs/ A B C Unit

Ctn/Case Case Qty/Qty Wt.

Boxed 9310 09310-3 1/2" 1.65 0.55 0.73 100/1000 12.8 9311 09311-0 3/4" 1.91 0.62 0.92 50/500 10.2 9312 09312-7 1" 2.30 0.75 1.15 50/500 15.3 9313 09313-4 1 1/4" 2.87 0.88 1.49 25/250 22.5 9314 09314-1 1 1/2" 3.14 1 1.85 25/100 15.2 9315 09315-8 2" 3.93 1.12 2.31 15/75 13.2 9316 09316-5 2 1/2" 4.90 1.25 3.00 25 11.6 9317 09317-2 3" 5.53 1.25 3.60 25 12.7 9318 09318-9 3 1/2" 6.18 1.25 4.13 25 17.5 9319 09319-6 4" 6.68 1.25 4.63 25 16.0

EM

T (

TH

INW

AL

L)

CO

ND

UIT

()

EMT Two Hole Straps

Use: Two hole straps are used for providing support for steel EMT Conduit where higher load bearing supports are desired as required by the National Electrical Code. • Click-On Type Materials: • Stamped Steel Finish: • Zinc Plated

Standards: UL 2239 CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

EMT Nail Strap

Use: Nail straps are used to secure steel EMT Conduit to wooden structure members. Can be used in place of one or two hole straps.

EMT (THINW ALL) CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions Pcs/ Ctn/Case Case Unit Qty/Qty Wt. A B C

Boxed 9330 09330-1 1/2" 2.12 0.55 0.73 50/500 17.6 9331 09331-8 3/4" 2.70 0.63 0.93 50/500 14.2 9332 09332-5 1" 3.01 0.68 1.11 50/200 17.6 9333 09333-2 1 1/4" 3.74 0.75 1.45 50 15.5 9334 09334-9 1 1/2" 4.21 0.86 1.68 50 20.3 9335 09335-6 2" 4.76 1.00 2.20 10/50 6.4

* 9336 09336-3 2 1/2" 5.88 1.00 2.91 25 5.1 * 9337 09337-0 3" 6.50 1.00 3.53 25 5.9 * 9338 09338-7 3 1/2" 7.38 1.00 4.03 25 8.3 * 9339 09339-4 4" 8.00 1.00 4.53 25 9.1

*EMT & RIGID

EMT (THINW ALL) CONDUIT Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed 9377 09377-6 1/2" 2.00 0.350 100/1000 7.3 9378 09378-3 3/4" 2.12 0.46 100/1000 22.4 9379 09379-0 1" 2.25 0.58 100/1000 25.7

Materials: • Stamped Steel Finish: • Zinc Plated

TE13131C113 MIFF www.tedd i co bwf.co m Teddico/BWF Pittsburgh, Pa. 15205

ELECTRICAL ARC/DUCTS W

Use:One hole straps are used for providing support for

steel EMT Conduit as required by the National

Electrical Code.

• Click-On Type

Materials:• Stamped Steel

Finish: • Zinc Plated

EMT One Hole Straps

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed

9311 09311-0 3/4" 1.91 0.62 0.92 - 50/500 10.2

9312 09312-7 1" 2.30 0.75 1.15 - 50/500 15.3

9313 09313-4 1 1/4" 2.87 0.88 1.49 - 25/250 22.5

9314 09314-1 1 1/2" 3.14 1 1.85 - 25/100 15.2

9315 09315-8 2" 3.93 1.12 2.31 - 15/75 13.2

9316 09316-5 2 1/2" 4.90 1.25 3.00 - 25 11.6

9317 09317-2 3" 5.53 1.25 3.60 - 25 12.7

9318 09318-9 3 1/2" 6.18 1.25 4.13 - 25 17.5

9319 09319-6 4" 6.68 1.25 4.63 - 25 16.0

AC

B

Use:Nail straps are used to secure steel EMT Conduit

to wooden structure members. Can be used in

place of one or two hole straps.

Materials:• Stamped Steel

Finish: • Zinc Plated

EMT Nail Strap

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9377 09377-6 1/2" 2.00 0.350 - 100/1000 7.3

9378 09378-3 3/4" 2.12 0.46 - 100/1000 22.4

9379 09379-0 1" 2.25 0.58 - 100/1000 25.7B

A

Use:Two hole straps are used for providing support for

steel EMT Conduit where higher load bearing

supports are desired as required by the National

Electrical Code.

• Click-On Type

Materials:• Stamped Steel

Finish: • Zinc Plated

Standards:UL 2239

CSA C22.2 No. 18

NEMA FB-1

NEC Article 348

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9330 09330-1 1/2" 2.12 0.55 0.73 - 50/500 17.6

9331 09331-8 3/4" 2.70 0.63 0.93 - 50/500 14.2

9332 09332-5 1" 3.01 0.68 1.11 - 50/200 17.6

9333 09333-2 1 1/4" 3.74 0.75 1.45 - 50 15.5

9334 09334-9 1 1/2" 4.21 0.86 1.68 - 50 20.3

9335 09335-6 2" 4.76 1.00 2.20 - 10/50 6.4

9336 09336-3 2 1/2" 5.88 1.00 2.91 - 25 5.1

9337 09337-0 3" 6.50 1.00 3.53 - 25 5.9

9338 09338-7 3 1/2" 7.38 1.00 4.03 - 25 8.3

9339 09339-4 4" 8.00 1.00 4.53 - 25 9.1

C

BA

EM

T (

TH

INW

ALL

) C

ON

DU

IT

9310 09310-3 1/2" 1.65 0.55 0.73 - 100/1000 12.8

Teddico/BWF Pittsburgh, Pa. 152051-9www.teddicobwf.com

EMT (THINW ALL) CONDUIT

EMT (THINW ALL) CONDUIT

EMT (THINW ALL) CONDUIT

EMT Two Hole Straps

*EMT & RIGID

****

Page 12: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Set Screw LR Conduit Bodies A

EMT (THINWALL) CONDUIT Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Use: Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction. Assembled with Cover and Gasket.

• Assembled with Cover and Gasket.

Boxed

D100-CGV 15600-6 1/2" 4.30 1.30 2.40

D101-CGV 15606-8 3/4" 5.00 1.50 2.60

D102-CGV 15612-9 1" 5.80 1.80 2.90

D103-CGV 15618-1 11/4" 7.80 2.50 3.70

D104-CGV 15624-2 11/2" 7.80 2.50 3.90

D105-CGV 15630-3 2" 9.80 3.20 4.70 16-CG 15775-1 21/2" 10.50 4.40 5.60 17-CG 15776-8 3" 10.50 4.50 6.00 18-CG 15777-5 3 1/2" 15.47 5.43 7.36 19-CG 15778-2 4" 15.47 5.43 7.36

27 7 15 7.5 14 9 4 5.5 4 6 2 4.5 1 5.6 1 6.5 1 8.5 1 8.6

Materials: • Aluminum Die-Cast • Stamped Aluminum Cover and Neoprene Gasket

Certification:

0 E121488 LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

Set Screw LL Conduit Bodies

Brt Use: Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction. Assembled with Cover and Gasket.

• Assembled with Cover and Gasket.

Materials: • Aluminum Die-Cast • Stamped Aluminum Cover and Neoprene Gasket

Certification:

E121488 LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

*"D" bodies are also threaded for rigid

EMT (THINWALL) CONDUIT Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed

D200-CGV 15636-5 1/2" 4.30 1.30 2.40

D201-CGV 15642-6 3/4" 5.00 1.50 2.60

D202-CGV 15648-8 1" 5.80 1.80 2.90

D203-CGV 15654-9 11/4" 7.80 2.50 3.70

D204-CGV 15660-0 11/2" 7.80 2.50 3.90

D205-CGV 15666-2 2" 9.80 3.20 4.70 26-CG 15779-9 2 1/2" 10.50 4.40 5.60 27-CG 15780-0 3" 10.50 4.50 6.00 28-CG 15781-2 3 1/2" 15.47 5.43 7.36 29-CG 15782-9 4" 15.47 5.43 7.36

*"D" bodies are also threaded for rigid

27 7 15 7.5 14 9 4 5.5 4 6 2 5.5 1 5.6 1 6.5 1 8.5 1 8.6

Teddico/BWF Pittsburgh, Pa. 15205 TECICIIICCD BWF ELECTRICAL PRODUCTS W

www.teddicobwf.com

Use:Conduit bodies are used to gain access to the

interior of a raceway for wire pulling, inspection

and maintenance where the raceway changes

direction. Assembled with Cover and Gasket.

• Assembled with Cover and Gasket.

Materials:• Aluminum Die-Cast

Certification:E121488 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 348

Set Screw L R Conduit Bodies EMT (THINWALL) CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

BoxedD100-CGV 15600-6 1/2" 4.30 1.30 2.40 - 27 7

D101-CGV 15606-8 3/4" 5.00 1.50 2.60 - 15 7.5

D102-CGV 15612-9 1" 5.80 1.80 2.90 - 14 9

D103-CGV 15618-1 1 1/4" 7.80 2.50 3.70 - 4 5.5

D104-CGV 15624-2 1 1/2" 7.80 2.50 3.90 - 4 6

D105-CGV 15630-3 2" 9.80 3.20 4.70 - 2 4.5

16-CG 15775-1 2 1/2" 10.50 4.40 5.60 - 1 5.6

17-CG 15776-8 3" 10.50 4.50 6.00 - 1 6.5

18-CG 15777-5 3 1/2" 15.47 5.43 7.36 - 1 8.5

19-CG 15778-2 4" 15.47 5.43 7.36 - 1 8.6

Use:Conduit bodies are used to gain access to the

interior of a raceway for wire pulling, inspection

and maintenance where the raceway changes

direction. Assembled with Cover and Gasket.

• Assembled with Cover and Gasket.

Materials:• Aluminum Die-Cast

Certification:E121488 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 348

Set Screw L L Conduit Bodies EMT (THINWALL) CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

BoxedD200-CGV 15636-5 1/2" 4.30 1.30 2.40 - 27 7

D201-CGV 15642-6 3/4" 5.00 1.50 2.60 - 15 7.5

D202-CGV 15648-8 1" 5.80 1.80 2.90 - 14 9

D203-CGV 15654-9 1 1/4" 7.80 2.50 3.70 - 4 5.5

D204-CGV 15660-0 1 1/2" 7.80 2.50 3.90 - 4 6

D205-CGV 15666-2 2" 9.80 3.20 4.70 - 2 5.5

26-CG 15779-9 2 1/2" 10.50 4.40 5.60 - 1 5.6

27-CG 15780-0 3" 10.50 4.50 6.00 - 1 6.5

28-CG 15781-2 3 1/2" 15.47 5.43 7.36 - 1 8.5

29-CG 15782-9 4" 15.47 5.43 7.36 - 1 8.6

EM

T (T

HIN

WA

LL) CO

ND

UIT

Teddico/BWF Pittsburgh, Pa. 15205

B

A

C

* "D" bodies are also threaded for rigid

A

B

C

* "D" bodies are also threaded for rigid

• Stamped Aluminum Cover and Neoprene Gasket

• Stamped Aluminum Cover and Neoprene Gasket

>

>

>

>

>

>

1-10www.teddicobwf.com

Page 13: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Catalog Number

UPC No

0-87115

Trade Size

Nominal Dimensions Pcs/ A B C Unit

Ctn/Case Case Qty/Qty Wt.

Boxed D600-CGV 15708-9 1/2" 4.30 1.30 2.40 30 7 D601-CGV 15714-7 3/4" 5.00 1.50 2.60 18 7.5 D602-CGV 15720-1 1" 5.80 1.80 2.90 16 9 D603-CGV 15726-3 11/4" 7.80 2.50 3.70 8 5.5 D604-CGV 15732-4 11/2" 7.80 2.50 3.90 8 6 D605-CGV 15738-6 2" 9.80 3.20 4.70 2 5.5 66-CG 18771-0 21/2" 10.50 4.40 5.60 1 4.5 67-CG 71741-2 3" 10.50 4.50 6.00 1 5 68-CG 15787-4 31/2" 15.47 5.43 7.36 1 9.5 69-CG 71751-1 4" 15.47 5.43 7.36 1 8.5

*"D" bodies are also threaded for rigid

EMT (THINW ALL) CONDUIT

Set Screw LB Conduit Bodies EMT (THINW ALL) CONDUIT I

- -

Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction. Assembled with Cover and Gasket.

• Assembled with Cover and Gasket.

Materials: • Aluminum Die-Cast • Stamped Aluminum Cover and Neoprene Gasket Certification:

• E121488 (1• LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

Set Screw T Conduit Bodies A

Lica Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction. Assembled with Cover and Gasket.

• Assembled with Cover and Gasket.

Materials: • Aluminum Die-Cast • Stamped Aluminum Cover and Neoprene Gasket Certification:

E121488 G LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

Set Screw C Conduit Bodies A

,1 1/1111110,

C

Conduit bodies are used to ga'n access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction. Assembled with Cover and Gasket.

• Assembled with Cover and Gasket.

Materials: • Aluminum Die-Cast • Stamped Aluminum Cover and Neoprene Gasket

Certification:

• E121488 LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348

Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions A B C

Pcs/ Ctn/Case Case Unit Qty/Qty Wt.

Boxed D700-CGV 15744-7 1/2" 4.30 1.30 2.40 16 5 D701-CGV 15750-8 3/4" 5.00 1.50 2.60 12 5.5 D702-CGV 15756-0 1" 5.80 1.80 2.90 14 9 D703-CGV 15762-1 11/4" 7.80 2.50 3.70 4 7.5 D704-CGV 15768-3 11/2" 7.80 2.50 3.90 4 6.5 D705-CGV 15774-4 2" 9.80 3.20 4.70 2 5.5 76-CG 15788-1 21/2" 10.50 4.40 5.60 1 5.6 77-CG 15789-8 3" 10.50 4.50 6.00 1 6.5 78-CG 15790-4 31/2" 15.47 5.43 7.36 1 8.5 79-CG 15791-1 4" 15.47 5.43 7.36 1 8.6

*"D" bodies are also threaded for rigid

EMT (THINW ALL) CONDUIT Catalog Number

Boxed

UPC No 0-87115

Trade Size

Nominal Dimensions Pcs/ A B C Unit

Ctn/Case Case

Qty/Qty Wt.

D300-CGV 15672-3 1/2" 4.30 1.30 2.40 24 6.5 D301-CGV 15678-5 3/4" 5.00 1.50 2.60 18 7.5 D302-CGV 15684-6 1" 5.80 1.80 2.90 14 9 D303-CGV 15690-7 11/4" 7.80 2.50 3.70 8 12 D304-CGV 15696-9 11/2" 7.80 2.50 3.90 8 11 D305-CGV 15704-1 2" 9.80 3.20 4.70 2 5 36-CG 15783-6 21/2" 10.50 4.40 5.60 1 6.5 37-CG 15784-3 3" 10.50 4.50 6.00 1 7.5 38-CG 15785-0 31/2" 15.47 5.43 7.36 1 9 39-CG 15786-7 4" 15.47 5.43 7.36 1 12

*"D" bodies are also threaded for rigid

www.tedd i co bwf.co m Teddico/BWF Pittsburgh, Pa. 15205 TEDDICD MIFF ELECTRICAL ARC.DUCTS

Use:Conduit bodies are used to gain access to the

interior of a raceway for wire pulling, inspection

and maintenance where the raceway changes

direction. Assembled with Cover and Gasket.

• Assembled with Cover and Gasket.

Materials:• Aluminum Die-Cast

Certification:E121488 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 348

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

BoxedD600-CGV 15708-9 1/2" 4.30 1.30 2.40 - 30 7

D601-CGV 15714-7 3/4" 5.00 1.50 2.60 - 18 7.5

D602-CGV 15720-1 1" 5.80 1.80 2.90 - 16 9

D603-CGV 15726-3 1 1/4" 7.80 2.50 3.70 - 8 5.5

D604-CGV 15732-4 1 1/2" 7.80 2.50 3.90 - 8 6

D605-CGV 15738-6 2" 9.80 3.20 4.70 - 2 5.5

66-CG 2 1/2" 10.50 4.40 5.60 - 1 4.5

67-CG 3" 10.50 4.50 6.00 - 1 5

68-CG 15787-4 3 1/2" 15.47 5.43 7.36 - 1 9.5

69-CG 4" 15.47 5.43 7.36 - 1 8.5

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

BoxedD700-CGV 15744-7 1/2" 4.30 1.30 2.40 - 16 5

D701-CGV 15750-8 3/4" 5.00 1.50 2.60 - 12 5.5

D702-CGV 15756-0 1" 5.80 1.80 2.90 - 14 9

D703-CGV 15762-1 1 1/4" 7.80 2.50 3.70 - 4 7.5

D704-CGV 15768-3 1 1/2" 7.80 2.50 3.90 - 4 6.5

D705-CGV 15774-4 2" 9.80 3.20 4.70 - 2 5.5

76-CG 15788-1 2 1/2" 10.50 4.40 5.60 - 1 5.6

77-CG 15789-8 3" 10.50 4.50 6.00 - 1 6.5

78-CG 15790-4 3 1/2" 15.47 5.43 7.36 - 1 8.5

79-CG 15791-1 4" 15.47 5.43 7.36 - 1 8.6

EM

T (

TH

INW

ALL

) C

ON

DU

IT

Teddico/BWF Pittsburgh, Pa. 15205

Use:Conduit bodies are used to gain access to the

interior of a raceway for wire pulling, inspection

and maintenance where the raceway changes

direction. Assembled with Cover and Gasket.

• Assembled with Cover and Gasket.

Materials:• Aluminum Die-Cast

Certification:E121488 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1NEC Article 348

Set Screw T Conduit Bodies

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

BoxedD300-CGV 15672-3 1/2" 4.30 1.30 2.40 - 24 6.5

D301-CGV 15678-5 3/4" 5.00 1.50 2.60 - 18 7.5

D302-CGV 15684-6 1" 5.80 1.80 2.90 - 14 9

D303-CGV 15690-7 1 1/4" 7.80 2.50 3.70 - 8 12

D304-CGV 15696-9 1 1/2" 7.80 2.50 3.90 - 8 11

D305-CGV 15704-1 2" 9.80 3.20 4.70 - 2 5

36-CG 15783-6 2 1/2" 10.50 4.40 5.60 - 1 6.5

37-CG 15784-3 3" 10.50 4.50 6.00 - 1 7.5

38-CG 15785-0 3 1/2" 15.47 5.43 7.36 - 1 9

39-CG 15786-7 4" 15.47 5.43 7.36 - 1 12

Conduit bodies are used to gain access to the

interior of a raceway for wire pulling, inspection

and maintenance where the raceway changes

direction. Assembled with Cover and Gasket.

• Assembled with Cover and Gasket.

Materials:• Aluminum Die-Cast

Certification:E121488 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 348

Set Screw C Conduit Bodies

Use:

Set Screw L B Conduit Bodies

18771-0

71751-1

A

B

C

C

A

B

A

B

C

• Stamped Aluminum Cover and Neoprene Gasket

• Stamped Aluminum Cover and Neoprene Gasket

• Stamped Aluminum Cover and Neoprene Gasket

* "D" bodies are also threaded for rigid

* "D" bodies are also threaded for rigid

* "D" bodies are also threaded for rigid

1-11 www.teddicobwf.com

71741-2

EMT (THINW ALL) CONDUIT

EMT (THINW ALL) CONDUIT

EMT (THINW ALL) CONDUIT

Page 14: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Conduit hangers are used to secure and suspend EMT, Rigid, IMC and PVC Conduits from overhead supports. • With Carriage Bolt and Nut Attached

EMT Conduit Hangers WI Nut & Bolt

(4/

EMT (THINWALL) CONDUIT Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed 9450 09450-6 1/2" 1.95 0.75 0.70 9451 09451-3 3/4" 2.21 0.75 0.82 9452 09452-0 1" 2.53 0.86 0.93 9452-E 09428-5 1 1/4" 2.72 0.86 0.98 9453 09453-7 1 1/2" 3.01 0.86 1.03 9455 09455-1 2" 3.31 0.96 1.10 9456 09456-8 2 1/2" 4.05 0.96 1.12 9457 09457-5 3" 4.60 1.18 1.25 9458 09458-2 3 1/2" 5.31 1.18 1.25 9459 09459-9 4" 5.31 1.18 1.25

50/500 38.6 100 8.3 100 10.0 100 12.2 100 13.5 100 18.9 50 10.7 25 7.5 10 4.6 10 4.6

Materials: • Stamped Steel

Finish: • Zinc Plated Certification:

E186443 LR104691

EMT Conduit Hangers W/O Nut & Bolt

jzt

Use Conduit hangers are used to secure and suspend EMT, Rigid, IMC and PVC Conduits from overhead supports. • Without Carriage Bolt and Nut Attached

Materials: • Stamped Steel

Finish: • Zinc Plated Certification:

E186443 LR104691

EMT (THINWALL) CONDUIT Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed 9440 09440-7 1/2" 1.95 0.75 0.70 9441 09441-4 3/4" 2.21 0.75 0.82 9442 09442-1 1" 2.53 0.86 0.93 9442-E 09427-8 1 1/4" 2.72 0.86 0.98 9443 09443-8 1 1/2" 3.01 0.86 1.03 9445 09445-2 2" 3.31 0.96 1.10 9446 09446-9 21/2" 4.05 0.96 1.12 9447 09447-6 3" 4.60 1.18 1.25 9448 09448-3 31/2" 5.31 1.18 1.25 9449 09449-0 4" 5.31 1.18 1.25

50/500 38.6 100 8.3 100 10.0 100 12.2 100 13.5 100 18.9 50 10.7 25 7.5 10 4.6 10 4.6

TECICIIICCD BWF ELECTRICAL PRODUCTS W

www.tedd i co bwf.co m Teddico/BWF Pittsburgh, Pa. 15205

Use:Conduit hangers are used to secure and suspend

EMT, Rigid, IMC and PVC Conduits from

overhead supports.

• With Carriage Bolt and Nut Attached

Materials:• Stamped Steel

Finish: • Zinc Plated

Certification:

EMT Conduit Hangers

EMT (THINWALL) CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9450 09450-6 1/2" 1.95 0.75 0.70 - 50/500 38.6

9451 09451-3 3/4" 2.21 0.75 0.82 - 100 8.3

9452 09452-0 1" 2.53 0.86 0.93 - 100 10.0

9452-E 09428-5 1 1/4" 2.72 0.86 0.98 - 100 12.2

9453 09453-7 1 1/2" 3.01 0.86 1.03 - 100 13.5

9455 09455-1 2" 3.31 0.96 1.10 - 100 18.9

9456 09456-8 2 1/2" 4.05 0.96 1.12 - 50 10.7

9457 09457-5 3" 4.60 1.18 1.25 - 25 7.5

9458 09458-2 3 1/2" 5.31 1.18 1.25 - 10 4.6

AB

C

Use:Conduit hangers are used to secure and suspend

EMT, Rigid, IMC and PVC Conduits from

overhead supports.

• Without Carriage Bolt and Nut Attached

Materials:• Stamped Steel

Finish: • Zinc Plated

Certification:

EMT Conduit HangersEMT (THINWALL) CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9440 09440-7 1/2" 1.95 0.75 0.70 - 50/500 38.6

9441 09441-4 3/4" 2.21 0.75 0.82 - 100 8.3

9442 09442-1 1" 2.53 0.86 0.93 - 100 10.0

9442-E 09427-8 1 1/4" 2.72 0.86 0.98 - 100 12.2

9443 09443-8 1 1/2" 3.01 0.86 1.03 - 100 13.5

9445 09445-2 2" 3.31 0.96 1.10 - 100 18.9

9446 09446-9 2 1/2" 4.05 0.96 1.12 - 50 10.7

9447 09447-6 3" 4.60 1.18 1.25 - 25 7.5

9448 09448-3 3 1/2" 5.31 1.18 1.25 - 10 4.6

AB

C

Teddico/BWF Pittsburgh, Pa. 15205

EM

T (T

HIN

WA

LL) CO

ND

UIT

W / Nut & Bolt

W /O Nut & Bolt

9459 09459-9 4" 5.31 1.18 1.25 - 10 4.6

9449 09449-0 4" 5.31 1.18 1.25 - 10 4.6

E186443 LR104691

E186443 LR104691

1-12www.teddicobwf.com

Page 15: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

0,

EMT To Flex Couplings EMT (THINW ALL) CONDUIT Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed 8217 08217-6 1/2"-3/8" 0.72 0.93 1.34

Use: Combination couplings are used to provide a transition from steel EMT conduit to Flexible Metal Conduit.

• Set Screw - Clamp Type

50/500 34.3

Materials: • Zinc Die-Cast Certification:

0 E210498® LR57925

JLU

KULL

LLLL

U

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348 & 350

Use: Combination couplings are used to provide a transition from steel EMT conduit to Flexible Metal Conduit.

• Set Screw - Squeeze Type

Materials: • Zinc Die-Cast Certification:

® E210498 LR57925

EMT To Flex Couplings

C

Use: Combination couplings are used to provide a transition from steel EMT Conduit to Flexible Metal Conduit.

• Compression - Screw in Type

EMT (THINW ALL) CONDUIT Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed 8218 08218-3 1/2"-1/2" 0.93 0.94 1.62 25/250 21.9 8219 08219-0 3/4"-3/4" 0.94 01.12 1.97 25/250 36

EMT (THINW ALL) CONDUIT Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed 8210 08210-7 1/2" 1.40 0.92 0.15 50/500 40.9 8211 08211-4 3/4" 1.52 1.12 0.20 25/250 30.8

Materials: • Zinc Die-Cast Certification:

® E155411

• LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Articles 348 & 350

www.tedd i co bwf.co m Teddico/BWF Pittsburgh, Pa. 15205 TEDDICD MIFF ELECTRICAL ARC.DUCTS

Use:Combination couplings are used to provide a

transition from steel EMT conduit to Flexible Metal

Conduit.

• Set Screw - Squeeze Type

Materials:• Zinc Die-Cast

Certification:E210498 LR57925

EMT To Flex CouplingsCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8217 08217-6 1/2"-3/8" 0.72 0.93 1.34 - 50/500 34.3

Use:Combination couplings are used to provide a

transition from steel EMT Conduit to Flexible Metal

Conduit.

• Compression - Screw in Type

Materials:• Zinc Die-Cast

Certification:E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18

NEMA FB-1 NEC Articles 348 & 350

EMT To Flex Couplings

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8210 08210-7 1/2" 1.40 0.92 0.15 - 50/500 40.9

8211 08211-4 3/4" 1.52 1.12 0.20 - 25/250 30.8

A

C

B

A B

C

AB

C

Teddico/BWF Pittsburgh, Pa. 15205

EM

T (

TH

INW

ALL

) C

ON

DU

IT

Use:Combination couplings are used to provide a

transition from steel EMT conduit to Flexible Metal

Conduit.

• Set Screw - Clamp Type

Materials:• Zinc Die-Cast

Certification:E210498 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 348 & 350

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8218 08218-3 1/2"-1/2" 0.93 0.94 1.62 - 25/250 21.9

8219 08219-0 3/4"-3/4" 0.94 01.12 1.97 - 25/250 36

1-13 www.teddicobwf.com

EMT (THINW ALL) CONDUIT

EMT (THINW ALL) CONDUIT

EMT (THINW ALL) CONDUIT

Page 16: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

EMT Compression To Rigid Couplings EMT (THINW ALL) CONDUIT Catalog UPC No Trade Nominal Dimensions Ctn/Case Case Number 0-87115 Size A B CD Qty/Qty Wt.

Boxed 9460 09460-5 1/2" 1 5/16" 1 1/8" 7/8" 11/16" 10/100 13.7

Use: Combination couplings are used to provide a transition from steel EMT conduit to Rigid Conduit. • Compression - Threaded Type

Materials: • Steel

Certification:

Ous E207875

9461 09461-2 3/4" 17/16" 13/8" 11/8" 3/4" 10/100 25.1 9462 09462-9 1" 11/2" 1 11/16" 1 3/8" 13/16" 10/100 33.3

Standards: UL 514B NEMA FB-1

EMT Set Screw To Rigid Couplings EMT (THINW ALL) CONDUIT Catalog UPC No Trade Nominal Dimensions Ctn/Case Case Number 0-87115 Size A B CD Qty/Qty Wt.

Boxed 9463 09463-6 1/2" 1" 2 3/8" 7/8" 15/16" 25/250 34.3

9464 09464-3 3/4" 1 1/4" 2 13/16" 1 1/8" 1 1/8" 10/100 25.1 9465 09465-0 1" 1 1/2" 3" 1 3/8" 1 13/16" 10/100 33.3

Use: Combination couplings are used to provide a transition from steel EMT Conduit to Rigid Conduit. • Set Screw - Set Screw Type

Materials: • Steel

Certification:

cOus E207875

Standards: UL 514B NEMA FB-1

TECICIIICCD BWF ELECTRICAL PRODUCTS W

www.tedd i co bwf.co m Teddico/BWF Pittsburgh, Pa. 15205

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C D Qty/Qty Wt.

Boxed9460 09460-5 1/2" 1 5/16" 1 1/8" 7/8" 11/16" 10/100 13.7

Use:Combination couplings are used to provide a

transition from steel EMT Conduit to Rigid

Conduit.

• Set Screw - Set Screw Type

Materials:• Steel

Certification:

Standards:UL 514B

NEMA FB-1

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C D Qty/Qty Wt.

Boxed

Teddico/BWF Pittsburgh, Pa. 15205

EM

T (T

HIN

WA

LL) CO

ND

UIT

Use:Combination couplings are used to provide a

transition from steel EMT conduit to Rigid

Conduit.

• Compression - Threaded Type

Materials:• Steel

Certification:

Standards:UL 514BNEMA FB-1

EMT Compression To Rigid Couplings

E207875

9461 09461-2 3/4" 1 7/16" 1 3/8" 1 1/8" 3/4" 10/100 25.1

9462 09462-9 1" 1 1/2" 1 11/16" 1 3/8" 13/16" 10/100 33.3

EMT Set Screw To Rigid Couplings

E207875

9463 09463-6 1/2" 1" 2 3/8" 7/8" 15/16" 25/250 34.3

9464 09464-3 3/4" 1 1/4" 2 13/16" 1 1/8" 1 1/8" 10/100 25.1

9465 09465-0 1" 1 1/2" 3" 1 3/8" 1 13/16" 10/100 33.3

1-14www.teddicobwf.com

EMT (THINW ALL) CONDUIT

EMT (THINW ALL) CONDUIT

Page 17: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

EMT/Rigid Clamp Backs

Use: • Used to provide space between electrical

metallic tubing and mounting surface.

Materials: • Malleable iron

Finish: • Zinc Plated

Standards: CSA File No. LR57925

EMT Conduit Benders

Use: • Used to bend EMT conduit to the desired radius.

• Cast in angle indicators

• Handle not included

Materials: • Die Cast Aluminum

Finish: • Zinc Plated

EMT (THINWALL) CONDUIT Catalog Number

UPC No 0-31857

Trade Size

Ctn/Case Case Qty/Qty Wt.

Boxed 9500 09500-8 1/2" 25/250 27.7 9501 09501-5 3/4" 25/250 29.2 9502 09502-2 1" 25/125 20.4 9503 09503-9 11/4" 20/100 22.3 9504 09504-6 1 1/2" 10/100 21.6 9505 09505-3 2" 5/50 30.9 9506 09506-0 21/2" 10 7.6 9507 09507-7 3" 10 10.5 9508 09508-4 31/2" 10 15.6 9509 09509-1 4" 10 17.1

EMT (THINWALL) CONDUIT

Catalog UPC No Trade Ctn/Case Case Number 0-87115 Size Qty/Qty Wt.

Boxed 9890 09890-0 1/2"-3/8" 10 10 9891 09891-7 1/2"-1/2" 10 20 9892 09892-4 3/4"-3/4" 2 7

EMT Conduit Bender Handles EMT (THINWALL) CONDUIT W/0 Head

Catalog UPC No Trade Ctn/Case Case Number 0-87115 Size Qty/Qty Wt.

Boxed 9893 09893-1 1/2"-3/4" 10 37.5 9894 09894-8 1" 2 9.5

Use: • For use with conduit bender heads

• Head not included

Materials: • Steel

Finish: • Textured black powder coat

1-15

TE13131C113 MIFF www.tedd i co bwf.co m Teddico/BWF Pittsburgh, Pa. 15205

ELECTRICAL ARC.DUCTS

Use:Used to provide space between electrical

metallic tubing and mounting surface.•

Materials:• Malleable iron

Finish: • Zinc Plated

Standards:CSA File No. LR57925

EMT/Rigid Clamp Back s EMT (THINWALL) CONDUITCatalog UPC No Trade Ctn/Case Case

Number 0-31857 Size Qty/Qty Wt.

Boxed9500 09500-8 1/2" 25/250 27.7

9501 09501-5 3/4" 25/250 29.2

9502 09502-2 1" 25/125 20.4

9503 09503-9 1 1/4" 20/100 22.3

9504 09504-6 1 1/2" 10/100 21.6

9505 09505-3 2" 5/50 30.9

9506 09506-0 2 1/2" 10 7.6

9507 09507-7 3" 10 10.5

9508 09508-4 3 1/2" 10 15.6

9509 09509-1 4" 10 17.1

EMT (THINWALL) CONDUIT

Catalog UPC No Trade Ctn/Case Case

Number 0-87115 Size Qty/Qty Wt.

Boxed9890 09890-0 1/2"-3/8" 10 10

9891 09891-7 1/2"-1/2" 10 20

9892 09892-4 3/4"-3/4" 2 7

EMT Conduit Benders

EMT (THINWALL) CONDUITCatalog UPC No Trade Ctn/Case Case

Number 0-87115 Size Qty/Qty Wt.

Boxed9893 09893-1 1/2"-3/4" 10 37.5

9894 09894-8 1" 2 9.5

EMT Conduit Bender HandlesW /O Head

Teddico/BWF Pittsburgh, Pa. 15205

EM

T (

TH

INW

ALL

) C

ON

DU

IT

Use:Used to bend EMT conduit to the desired radius.•

Materials:• Die Cast Aluminum

Finish: • Zinc Plated

Cast in angle indicators•

Use:For use with conduit bender heads•

Materials:• Steel

Finish: • Textured black powder coat

Head not included•

Handle not included•

1-15 www.teddicobwf.com

Page 18: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Teddico/BWF Pittsburgh, Pa. 15205 www.teddicobwf.com TECICIIICCD BWF ELECTRICAL PRODUCTS W

Screw-In Greenfield Connectors

Use: Screw-in type connectors are used to terminate Flexible Metal Conduit to a knock-out in a dry location box or enclosure, where minimum spacing is desired between the conduits.

Materials: • Zinc Die-Cast Certification:

E155411 41• LR57925

Standards:_

UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 350

BX • MC • FLEX Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions Pcs/ Ctn/Case Case Unit Qty/Qty Wt. A B C

Boxed 8356 08356-2 3/8" 1.30 0.92 0.41 50/500 24.14 8350 08350-0 1/2" 1.37 0.92 0.41 50/500 26.24 8351 08351-7 3/4" 1.63 1.12 0.43 25/250 20.12 8352 08352-4 1" 1.92 1.35 0.56 25/250 39.57 8353 08353-1 1 1/4" 2.12 1.75 0.61 10/100 22.51 8354 08354-8 1 1/2" 2.32 2.1 0.62 10/40 14.21 8355 08355-5 2" 2.55 2.66 0.75 10/40 22.13

Boxed w/ Insulated Throat 8360 08360-9 1/2" 1.37 0.92 0.41 50/500 26.24 8361 08361-6 3/4" 1.63 1.12 0.43 25/250 20.12 8362 08362-3 1" 1.92 1.35 0.56 25/250 39.57 8363 08363-0 1 1/4" 2.12 1.75 0.61 10/100 22.51 8364 08364-7 1 1/2" 2.32 2.1 0.62 10/40 14.21 8365 08365-4 2" 2.55 2.66 0.75 10/40 22.13

Trade Size For Cable Sizes 3/8" For Regular Wall Steel or Aluminum Flexible Metal Conduit.

1/2" For Regular Wall Steel or Aluminum Flexible Metal Conduit.

3/4" For Regular or Reduced Wall Steel or Aluminum Flexible Metal Conduit.

1"-2" For Regular Wall Steel or Aluminum Flexible Metal Conduit.

Screw-In Greenfield Couplings

Use: Screw-in type couplings are used to join lengths of Flexible Metal Conduit.

Materials: • Zinc Die-Cast Certification:

E155411 LR57925

BX • MC • FLEX

Boxed 8370 08370-8 1/2" 1.79 0.97 0.20 50/500 23.15 8371 08371-5 3/4" 2.00 1.21 0.22 25/250 19.84

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 3508

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Use:Screw-in type connectors are used to terminate

Flexible Metal Conduit to a knock-out in a dry

location box or enclosure, where minimum

spacing is desired between the conduits.

Materials:• Zinc Die-Cast

Certification:E155411 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 350

Screw-In Greenfield Connectors BX • MC • FLEXCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8356 08356-2 3/8" 1.30 0.92 0.41 - 50/500 24.14

8350 08350-0 1/2" 1.37 0.92 0.41 - 50/500 26.24

8351 08351-7 3/4" 1.63 1.12 0.43 - 25/250 20.12

8352 08352-4 1" 1.92 1.35 0.56 - 25/250 39.57

8353 08353-1 1 1/4" 2.12 1.75 0.61 - 10/100 22.51

8354 08354-8 1 1/2" 2.32 2.1 0.62 - 10/40 14.21

8355 08355-5 2" 2.55 2.66 0.75 - 10/40 22.13

Boxed w/ Insulated Throat8360 08360-9 1/2" 1.37 0.92 0.41 - 50/500 26.24

8361 08361-6 3/4" 1.63 1.12 0.43 - 25/250 20.12

8362 08362-3 1" 1.92 1.35 0.56 - 25/250 39.57

8363 08363-0 1 1/4" 2.12 1.75 0.61 - 10/100 22.51

8364 08364-7 1 1/2" 2.32 2.1 0.62 - 10/40 14.21

8365 08365-4 2" 2.55 2.66 0.75 - 10/40 22.13

AC

B

Use:Screw-in type couplings are used to join lengths of

Flexible Metal Conduit.

Materials:• Zinc Die-Cast

Certification:E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18NEMA FB-1 NEC Article 3508

Screw-In Greenfield Couplings BX • MC • FLEXCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8370 08370-8 1/2" 1.79 0.97 0.20 - 50/500 23.15

8371 08371-5 3/4" 2.00 1.21 0.22 - 25/250 19.84

B

AC

Trade Size For Cable Sizes3/8" For Regular Wall Steel or Aluminum Flexible Metal Conduit.

1/2" For Regular Wall Steel or Aluminum Flexible Metal Conduit.

3/4" For Regular or Reduced Wall Steel or Aluminum Flexible Metal Conduit.

1"-2” For Regular Wall Steel or Aluminum Flexible Metal Conduit.

MC

B

X

FLEX

Teddico/BWF Pittsburgh, Pa. 15205

��

2-1www.teddicobwf.com

Page 19: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

90° Angle Connectors

A

Use: 90° connectors are used to make a 90° termination of Armored Cable, Metal Clad Cable or Flexible Metal Conduit to a knock-out or unthreaded slip hole in a dry location box or enclosure. • Squeeze Type

90° Angle Connectors (Malleable Iron)

A

Use: 90° connectors are used to make a 90° termination of Armored Cable, Metal Clad Cable or Flexible Metal Conduit to a knock-out or unthreaded slip hole in a dry location box or enclosure. • Squeeze Type

Materials: • Malleable Iron Certification:

® E155411 LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Articles 350, 333 & 334

BX • MC • FLEX Catalog Number

UPC No

0-87115

Trade Size

Nominal Dimensions Pcs/ A B C Unit

Ctn/Case Case Qty/Qty Wt.

Boxed 8200 08200-8 3/8" 1.32 1.30 0.39 50/500 44.8 8180 08180-3 1/2" 1.64 1.63 0.43 25/250 31.1 8181 08181-0 3/4" 1.77 1.89 0.43 10/100 18.5 8182 08182-7 1" 2.13 2.30 0.53 10 3.2 8183 08183-0 1 1/4" 3.00 2.69 0.59 10 4.8 8184 08184-7 1 1/2" 4.80 3.59 0.70 4 4.4 8185 08185-4 2" 4.80 3.59 0.70 4 4.6 8186 08186-5 2 1/2" 4.80 4.45 0.85 5 12.9 8187 08187-2 3" 5.58 5.00 0.85 1 3.5 8188 08188-9 3 1/2" 6.41 5.51 1.02 1 6.3 8189 08189-6 4" 7.22 6.10 1.06 1 7.4

r.) r:) X

31d

• D

IN

• X

8

Materials: • Zinc Die-Cast Boxed w/ insulated throat Certification: 8201 08201-5 3/8" 1.32 1.30 0.39 50/500 44.8 ® E155411 Go LR57925 8190 08190-2 1/2" 1.64 1.63 0.43 25/250 31.1

8191 08191-9 3/4" 1.77 1.89 0.43 10/100 18.5 Standards: UL 514B 8192 08192-6 1" 2.13 2.30 0.53 10 3.2

8193 08193-3 1 1/4" 3.00 2.69 0.59 10 4.8 CSA C22.2 No. 18 8194 08194-0 1 1/2" 4.80 3.59 0.70 4 4.4 NEMA FB-1 8195 08195-7 2" 4.80 3.59 0.70 4 4.6 NEC Articles 350, 333 & 334 8196 08196-4 2 1/2" 4.80 4.45 0.85 5 12.9 8197 08197-1 3" 5.58 5.00 0.85 1 3.5 8198 08198-8 3 1/2" 6.41 5.51 1.02 1 6.3 8199 08199-5 4" 7.22 6.10 1.06 1 7.4

Trade Size For Cable Sizes 3/8" For regular Wall Steel or Aluminum Flexible Metal Conduit. For 14-2 through 10-3

Steel or Aluminum Armored Cable. For 14-2 through 10-3 Interlocking Steel or Aluminum Metal clad Cable.

1/2" For Regular Wall Steel or Aluminum Flexible Metal Conduit. For 8-2 through 8-3 Steel or Aluminum Armored Cable. For 8-2 through 8-3 interlocking Steel or Aluminum Metal clad Cable.

3/4" For regular or Reduced Wall Steel or Aluminum Flexible Metal Conduit.

BX • MC • FLEX Catalog Number

UPC No

0-87115

Trade Size

Nominal Dimensions A B C

Pcs/ Ctn/Case Case Unit Qty/Qty Wt.

Boxed

9530 09530-5 1/2" 1.64 1.63 0.43 25/250 31.1 9531 09531-2 3/4" 1.77 1.89 0.43 10/100 18.5 9532 09532-9 1" 2.13 2.30 0.53 10 3.2 9533 09533-6 1 1/4" 3.00 2.69 0.59 10 4.8 9534 09534-3 1 1/2" 4.80 3.59 0.70 4 4.4 9535 09535-0 2" 4.80 3.59 0.70 4 4.6 9536 09536-7 2 1/2" 4.80 4.45 0.85 5 12.9 9537 09537-4 3" 5.58 5.00 0.85 1 3.5 9538 09538-1 3 1/2" 6.41 5.51 1.02 1 6.3 9539 09539-8 4"

Boxed w/ insulated throat

7.22 6.10 1.06 1 7.4

95301 99530-8 1/2" 1.64 1.63 0.43 25/250 31.1 95311 99531-5 3/4" 1.77 1.89 0.43 10/100 18.5 95321 99532-2 1" 2.13 2.30 0.53 10 3.2 95331 99533-9 1 1/4" 3.00 2.69 0.59 10 4.8 95341 99534-6 1 1/2" 4.80 3.59 0.70 4 4.4 95351 99535-3 2" 4.80 3.59 0.70 4 4.6 95361 99536-0 2 1/2" 4.80 4.45 0.85 5 12.9 95371 99537-7 3" 5.58 5.00 0.85 1 3.5 95381 99538-4 3 1/2" 6.41 5.51 1.02 1 6.3 95391 99539-1 4" 7.22 6.10 1.06 1 7.4

TE13131C13 ThreF,„w ELECTRICAL PRCIDUCTS

www.teddicobwf.com Teddico/BWF Pittsburgh, Pa. 15205

Use:90° connectors are used to make a 90° termination

of Armored Cable, Metal Clad Cable or Flexible

Metal Conduit to a knock-out or unthreaded slip

hole in a dry location box or enclosure.

Materials:• Zinc Die-Cast

Certification:E155411 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Articles 350, 333 & 334

90° Angle Connectors BX • MC • FLEXCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8200 08200-8 3/8" 1.32 1.30 0.39 - 50/500 44.8

8180 08180-3 1/2" 1.64 1.63 0.43 - 25/250 31.1

8181 08181-0 3/4" 1.77 1.89 0.43 - 10/100 18.5

8182 08182-7 1" 2.13 2.30 0.53 - 10 3.2

8183 08183-0 1 1/4" 3.00 2.69 0.59 - 10 4.8

8184 08184-7 1 1/2" 4.80 3.59 0.70 - 4 4.4

8185 08185-4 2" 4.80 3.59 0.70 - 4 4.6

8186 08186-5 2 1/2" 4.80 4.45 0.85 - 5 12.9

8187 08187-2 3" 5.58 5.00 0.85 - 1 3.5

8188 08188-9 3 1/2" 6.41 5.51 1.02 - 1 6.3

8189 08189-6 4" 7.22 6.10 1.06 - 1 7.4

A

B

C

Trade Size For Cable Sizes3/8" For regular Wall Steel or Aluminum Flexible Metal Conduit. For 14-2 through 10-3

Steel or Aluminum Armored Cable. For 14-2 through 10-3 Interlocking Steel or

Aluminum Metal clad Cable.

1/2" For Regular Wall Steel or Aluminum Flexible Metal Conduit. For 8-2 through

8-3 Steel or Aluminum Armored Cable. For 8-2 through 8-3 interlocking Steel or

Aluminum Metal clad Cable.

3/4" For regular or Reduced Wall Steel or Aluminum Flexible Metal Conduit.

MC

BX

FLE

X�

Boxed w/ insulated throat8201 08201-5 3/8" 1.32 1.30 0.39 - 50/500 44.8

8190 08190-2 1/2" 1.64 1.63 0.43 - 25/250 31.1

8191 08191-9 3/4" 1.77 1.89 0.43 - 10/100 18.5

8192 08192-6 1" 2.13 2.30 0.53 - 10 3.2

8193 08193-3 1 1/4" 3.00 2.69 0.59 - 10 4.8

8194 08194-0 1 1/2" 4.80 3.59 0.70 - 4 4.4

8195 08195-7 2" 4.80 3.59 0.70 - 4 4.6

8196 08196-4 2 1/2" 4.80 4.45 0.85 - 5 12.9

8197 08197-1 3" 5.58 5.00 0.85 - 1 3.5

8198 08198-8 3 1/2" 6.41 5.51 1.02 - 1 6.3

8199 08199-5 4" 7.22 6.10 1.06 - 1 7.4

Teddico/BWF Pittsburgh, Pa. 15205

• Squeeze Type

Use:90° connectors are used to make a 90° termination

of Armored Cable, Metal Clad Cable or Flexible

Metal Conduit to a knock-out or unthreaded slip

hole in a dry location box or enclosure.

Materials:• Malleable Iron

Certification:E155411 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Articles 350, 333 & 334

90° Angle Connectors BX • MC • FLEXCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9530 09530-5 1/2" 1.64 1.63 0.43 - 25/250 31.1

9531 09531-2 3/4" 1.77 1.89 0.43 - 10/100 18.5

9532 09532-9 1" 2.13 2.30 0.53 - 10 3.2

9533 09533-6 1 1/4" 3.00 2.69 0.59 - 10 4.8

9534 09534-3 1 1/2" 4.80 3.59 0.70 - 4 4.4

9535 09535-0 2" 4.80 3.59 0.70 - 4 4.6

9536 09536-7 2 1/2" 4.80 4.45 0.85 - 5 12.9

9537 09537-4 3" 5.58 5.00 0.85 - 1 3.5

9538 09538-1 3 1/2" 6.41 5.51 1.02 - 1 6.3

9539 09539-8 4" 7.22 6.10 1.06 - 1 7.4

A

B

C

Boxed w/ insulated throat99530-8 1/2" 1.64 1.63 0.43 - 25/250 31.1

99531-5 3/4" 1.77 1.89 0.43 - 10/100 18.5

99532-2 1" 2.13 2.30 0.53 - 10 3.2

99533-9 1 1/4" 3.00 2.69 0.59 - 10 4.8

99534-6 1 1/2" 4.80 3.59 0.70 - 4 4.4

99535-3 2" 4.80 3.59 0.70 - 4 4.6

99536-0 2 1/2" 4.80 4.45 0.85 - 5 12.9

99537-7 3" 5.58 5.00 0.85 - 1 3.5

99538-4 3 1/2" 6.41 5.51 1.02 - 1 6.3

99539-1 4" 7.22 6.10 1.06 - 1 7.4

• Squeeze Type

9530I

9531I

9532I

9533I

9534I

9535I

9536I

9537I

9538I

9539I

(Malleable Iron)

www.teddicobwf.com2-2

Page 20: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Squeeze Connectors

Use: Squeeze connectors are used to terminate Flexible Metal Conduit to a knock-out in a dry location box or enclosure. • Squeeze Type

Materials: • Zinc Die-Cast Certification:

E155411

LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 350

A

BX • MC • FLEX Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

A

Boxed 8375 08375-3 3/8" 1.09 0.5 0.62 50/500 32.0 8380 08380-7 1/2" 1.50 0.5 0.99 25/250 21.6 8381 08381-4 3/4" 1.59 0.5 1.18 25/250 33.7 8382 08382-1 1" 1.75 0.5 1.45 10/100 21.0 8383 08383-8 11/4" 1.90 0.6 1.73 10/100 28.0 8384 08384-5 11/2" 2.00 0.6 2.00 5/50 18.0 8385 08385-2 2" 2.10 0.6 2.55 10/40 18.4 8386 08386-9 2 1/2" 1.75 0.5 1.45 5 4.5 8387 08387-6 3" 1.90 0.6 1.73 1/5 12.7 8388 08388-3 3 1/2" 2.00 0.6 2.00 1 1.7 8389 08389-0 4" 2.10 0.6 2.55 1 2.1 Boxed w/ insulated throat 8390 08390-6 1/2" 1.50 0.5 0.99 25/250 21.6 8391 08391-3 3/4" 1.59 0.5 1.18 25/250 33.7 8392 08392-0 1" 1.75 0.5 1.45 10/100 21.0 8393 08393-7 11/4" 1.90 0.6 1.73 10/100 28.0 8394 08394-4 11/2" 2.00 0.6 2.00 5/50 18.0 8395 08395-1 2" 2.10 0.6 2.55 10/40 18.4 8396 08396-8 2 1/2" 1.75 0.5 1.45 5 9.0 8397 08397-5 3" 1.90 0.6 1.73 1/5 12.7 8398 08398-2 3 1/2" 2.00 0.6 2.00 1 1.7 8399 08399-9 4" 2.10 0.6 2.55 1 2.1

Trade Size For Cable Sizes

3/8" For Regular or Reduced Wall Steel Flexible Metal Conduit. For 12-2 through 10-3 Steel or Aluminum aromored cable. For 12-2 through 10-3 Interlocking Steel or Aluminum Metal Clad Cable. Aromored Cable. For 6-3 Interlocking Steel or Aluminum Metal Clad Cable.

3/4" For Regular or Reduced Wall Steel or Aluminum Flexible Metal Conduit.

1/2" For Regular or Reduced Wall Steel Flexible Metal Conduit. For 6-3 Steel or Aluminum

BX • MC • FLEX Squeeze Connectors (Malleable Iron)

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed 9580 09580-0 1/2" 1.50 0.5 0.99 9581 09581-7 3/4" 1.59 0.5 1.18 9582 09582-4 1" 1.75 0.5 1.45 9583 09583-1 11/4" 1.90 0.6 1.73 9584 09584-8 1 1/2" 2.00 0.6 2.00 9585 09585-5 2" 2.10 0.6 2.55 9586 09586-2 2 1/2" 1.75 0.5 2.00 9587 09587-9 3" 1.90 0.6 1.73 9588 09588-6 3 1/2" 2.00 0.6 2.00 9589 09589-3 4" 2.10 0.6 2.55

Use: Squeeze connectors are used to terminate Flexible Metal Conduit to a knock-out in a dry location box or enclosure. • Squeeze Type Materials: • Malleable Iron Boxed w/ insulated throat

25/125 16.6 20/100 16.7 10/50 13.0 10/50 20.0 5/25 15.8 20 21.4 5 8.6 5 10.1 1 4.4 1 6.6

Certification: 95801 99580-3 1/2" 1.50 0.5 0.99 25/125 16.8

0 E155411 0 LR57925 95811 99581-0 3/4" 1.59 0.5 1.18 20/100 16.9

Standards: 95821 99582-7 1" 1.75 0.5 1.45 10/50 13.1

UL 514B CSA C22.2 No. 18 95831 99583-4 1 1/4" 1.90 0.6 1.73 10/50 20.1

NEMA FB-1 NEC Article 350 95841 99584-1 1 1/2" 2.00 0.6 2.00

99585-8 2" 5/25 15.9

95851 2.10 0.6 2.55 20 21.6

95861 99586-5 2 1/2" 1.75 0.5 1.45 5 8.7

95871 99587-2 3" 1.90 0.6 1.73 5 10.2

95881 99588-9 3 1/2" 2.00 0.6 2.00 1 4.5

95891 99589-6 4" 2.10 0.6 2.55 1 6.7

www.teddicobwf.com ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑L BWF

ELECTRICAL PRODUCTS W

Use:Squeeze connectors are used to terminate Flexible

Metal Conduit to a knock-out in a dry location box

or enclosure.

Materials:• Zinc Die-Cast

Certification:E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18

NEMA FB-1 NEC Article 350

Squeeze Connectors BX • MC • FLEXCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8375 08375-3 3/8" 1.09 0.5 0.62 - 50/500 32.0

8380 08380-7 1/2" 1.50 0.5 0.99 - 25/250 21.6

8381 08381-4 3/4" 1.59 0.5 1.18 - 25/250 33.7

8382 08382-1 1" 1.75 0.5 1.45 - 10/100 21.0

8383 08383-8 1 1/4" 1.90 0.6 1.73 - 10/100 28.0

8384 08384-5 1 1/2" 2.00 0.6 2.00 - 5/50 18.08385 2" 2.10 0.6 2.55 - 10/40 18.4

A

B

C

Trade Size For Cable Sizes3/8" For Regular or Reduced Wall Steel Flexible Metal Conduit. For 12-2 through 10-3

Steel or Aluminum aromored cable. For 12-2 through 10-3 Interlocking Steel or Aluminum Metal Clad Cable.

1/2" For Regular or Reduced Wall Steel Flexible Metal Conduit. For 6-3 Steel or Aluminum

Aromored Cable. For 6-3 Interlocking Steel or Aluminum Metal Clad Cable.

3/4" For Regular or Reduced Wall Steel or Aluminum Flexible Metal Conduit.

8386 08386-9 8387 08387-6 3" 1.90 0.6 1.73 - 1/5 12.7

8388 08388-3 3 1/2" 2.00 0.6 2.00 - 1 1.7

8389 08389-0 4" 2.10 0.6 2.55 - 1 2.1

Boxed w/ insulated throat8390 08390-6 1/2" 1.50 0.5 0.99 - 25/250 21.6

8391 08391-3 3/4" 1.59 0.5 1.18 - 25/250 33.7

8392 08392-0 1" 1.75 0.5 1.45 - 10/100 21.0

8393 08393-7 1 1/4" 1.90 0.6 1.73 - 10/100 28.0

8394 08394-4 1 1/2" 2.00 0.6 2.00 - 5/50 18.08395 08395-1 2" 2.10 0.6 2.55 - 10/40 18.4

8396 08396-8 2 1/2" 1.75 0.5 1.45 - 5 9.08397 08397-5 3" 1.90 0.6 1.73 - 1/5 12.7

8398 08398-2 3 1/2" 2.00 0.6 2.00 - 1 1.7

8399 08399-9 4" 2.10 0.6 2.55 - 1 2.1

MC

B

X �

FLEX

Teddico/BWF Pittsburgh, Pa. 15205

Teddico/BWF Pittsburgh, Pa. 15205

Use:Squeeze connectors are used to terminate Flexible

Metal Conduit to a knock-out in a dry location box

or enclosure.

Materials:• Malleable Iron

Certification:E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18

NEMA FB-1 NEC Article 350

Squeeze Connectors BX • MC • FLEXCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9580 09580-0 1/2" 1.50 0.5 0.99 - 25/125 16.6

9581 09581-7 3/4" 1.59 0.5 1.18 - 20/100 16.7

9582 09582-4 1" 1.75 0.5 1.45 - 10/50 13.0

9583 09583-1 1 1/4" 1.90 0.6 1.73 - 10/50 20.0

9584 09584-8 1 1/2" 2.00 0.6 2.00 - 5/25 15.89585 2" 2.10 0.6 2.55 - 20 21.4

A

B

C

9586 09586-2 9587 09587-9 3" 1.90 0.6 1.73 - 5 10.1

9588 09588-6 3 1/2" 2.00 0.6 2.00 - 1 4.4

9589 09589-3 4" 2.10 0.6 2.55 - 1 6.6

Boxed w/ insulated throat99580-3 1/2" 1.50 0.5 0.99 - 25/125 16.8

99581-0 3/4" 1.59 0.5 1.18 - 20/100 16.9

99582-7 1" 1.75 0.5 1.45 - 10/50 13.1

99583-4 1 1/4" 1.90 0.6 1.73 - 10/50 20.1

99584-1 1 1/2" 2.00 0.6 2.00 - 5/25 15.999585-8 2" 2.10 0.6 2.55 - 20 21.699586-5 2 1/2" 1.75 0.5 1.45 - 5 8.799587-2 3" 1.90 0.6 1.73 - 5 10.2

99588-9 3 1/2" 2.00 0.6 2.00 - 1 4.5

99589-6 4" 2.10 0.6 2.55 - 1 6.7

(Malleable Iron)

• Squeeze Type

• Squeeze Type

9580I

9581I

9582I

9583I

9584I9585I9586I

9587I

9588I

9589I

2 1/2" 1.75 0.5 1.45 - 5 4.5

2 1/2" 1.75 0.5 2.00 - 5 8.609585-5

08385-2

www.teddicobwf.com 2-3

Page 21: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Catalog UPC No Trade

Nominal Dimensions Ctn/Case Case Number 0-87115 Size

A B C Qty/Qty Wt.

BX • MC • FLEX

Boxed 8205 08205-3 3/8" 0.78 0.63 0.36 100/1000 46.7

BX Connector

Use: BX connectors are used to terminate steel Armored Cable to a 1/2" knock-out in a dry location box or enclosure. • End Stopped

Materials: • Zinc Die-Cast Certification:

E155411 • LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 333

Set screw Flex Connectors

Use: Set screw flex connectors are used to terminate Regular Wall Steel orAluminum Flexible Metal Conduit to a knock-out in a dry location box or enclosure • Set Screw

Materials: • Zinc Die-Cast Certification:

E155411 LR57925

Trade Size For Cable Sizes

3/8" For 14-2 (nominal OD .460") through 10-2 (nominal OD .598") Steel Armored Cable. For 14-2 (nominal OD .469") through 10-3 (nominal OD .600") Steel Interlocking Metal Clad Cable.

BX • MC • FLEX Catalog UPC No Trade

Nominal Dimensions Ctn/Case Case

Number 0-87115 Size

A B C Qty/Qty Wt.

Carded 8245 08245-7 1/2" 0.95 1.50 0.40 10/120 15.7 8241 08241-5 3/4" 1.15 1.55 0.49 5/60 11.1

Standards: UL 514B

CSA C22.2 No. 18 NEMA FB-1

NEC Article 350

Boxed 8244

Trade Size 3/8"

Combination Connector

Use: Clamp type connectors are used to terminate Armored Cable, Metal Clad Cable or Flexible Metal Conduit to a 1/2" knock-out in a dry box or enclosure.

• Male Hub Threads NPS

• End Stopped

Materials: • Zinc Die-Cast

Certification:

E155411 41• LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Articles 350, 333 & 334

BX • MC • FLEX

08244-2 3/8" 0.80 1.17 0.35 100/1000 50.1

For Cable Sizes For Regular Wall Steel or Aluminum Flexible Metal Conduit. For 14-2 through 10-2 Steel or Aluminum Armored Cable.

For 14-2(nominal OD .470") through 10-3 (nominal OD .610")

through 10-3 (nominal OD .600") Steel Interlocking Metal Clad

Cable.

Aluminum Interlocking Metal Clad Cable; 14-2 (nominal OD .469")

Catalog

UPC No Trade Nominal Dimensions Ctn/Case Case Number

0-87115 Size A B C Qty/Qty Wt.

TE131311C13 MIFF ELECTRICAL ARC.DUCTS

www.teddicobwf.com Teddico/BWF Pittsburgh, Pa. 15205

Use:Clamp type connectors are used to terminate

Armored Cable, Metal Clad Cable or Flexible

Metal Conduit to a 1/2" knock-out in a dry box or

enclosure.

• Male Hub Threads NPS

• End Stopped

Materials:• Zinc Die-Cast

Certification:E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18

NEMA FB-1 NEC Articles 350, 333 & 334

Combination Connector BX • MC • FLEXCatalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

Boxed8244 08244-2 3/8" 0.80 1.17 0.35 100/1000 50.1

B

A

C

Trade Size For Cable Sizes3/8" For Regular Wall Steel or Aluminum Flexible Metal Conduit.

For 14-2 through 10-2 Steel or Aluminum Armored Cable.

For 14-2(nominal OD .470") through 10-3 (nominal OD .610")

Aluminum Interlocking Metal Clad Cable; 14-2 (nominal OD .469")

through 10-3 (nominal OD .600" ) Steel Interlocking Metal Clad

Cable.

Use:BX connectors are used to terminate steel Armored

Cable to a 1/2" knock-out in a dry

location box or enclosure.

• End Stopped

Materials:• Zinc Die-Cast

Certification:E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18NEMA FB-1 NEC Article 333

BX Connector BX • MC • FLEXCatalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

Boxed8205 08205-3 3/8" 0.78 0.63 0.36 100/1000 46.7

B

A

C

Trade Size For Cable Sizes

3/8" For 14-2 (nominal OD .460") through 10-2 (nominal OD .598") Steel Armored Cable.

For 14-2 (nominal OD .469") through 10-3 (nominal OD .600") Steel Interlocking Metal

Clad Cable.

MC

B

X

FLE

X�

Teddico/BWF Pittsburgh, Pa. 15205

Use:Set screw flex connectors are used to terminate RegularWall Steel or Aluminum Flexible Metal Conduit to aknock-out in a dry location box or enclosure.

Materials:• Zinc Die-Cast

Certification:E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18NEMA FB-1 NEC Article 350

Set screw Flex Connectors

B

A

CBX • MC • FLEX

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

Carded8245 08245-7 1/2" 0.95 1.50 0.40 10/120 15.7

8241 08241-5 3/4" 1.15 1.55 0.49 5/60 11.1

• Set Screw

www.teddicobwf.com2-4

Page 22: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Saddle Connector

Catalog

UPC No Trade Nominal Dimensions Ctn/Case Case Number

0-87115 Size A B C Qty/Qty Wt.

Boxed

Catalog UPC No Trade Number 0-87115 Size

Nominal Dimensions Ctn/Case Case

A B C Qty/Qty Wt.

Boxed 8464 08464-4 1/2" 1.40 1.80 0.40 25/250

25.6

BX • MC • FLEX

8460 08460-6 3/8" 0.90 1.61 0.93 50/500 35.4

Use: Saddle connectors are used to terminate Armored and Metal Clad Cables to a 1/2" knock-out in a dry location box or enclosure. • UL Listed Locknut

• End Stopped Materials: • Zinc Die-Cast Certification:

01) E155411 • LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Articles 333 & 334

Strap Connector

Trade Size

For Cable Sizes

3/8" For 14-2 (nominal OD .465") through 10-3 (nominal OD .500") Steel Armored Cable; For 14-2 (nominal OD .480") through 10-3 (nominal OD .585") Aluminum Armored Cable. For 0.475" through 0.600" Steel Interlocking Metal Clad Cable . For 0.468" through 0.610" Aluminum Interlocking Metal Clad Cable. For 12/2 through 10/3 Oval NMSE Cable.

BX • MC • FLEX

Trade Size

1/2" Use: Strap Connectors are used to terminate Armored Cable and Metal Clad Cable to a steel outlet box or metal enclosure.

Materials: • Zinc Die-Cast Certification:

E155411 LR57925

For Cable Sizes

For 8-4 (nominal OD For 8-4 (nominal OD Cable. For 0.680" through 0. For 0.675" through 0.

.785") through 8-2 (nominal OD .680") Steel Armored Cable;

.780") through 8-2 (nominal OD .680") Aluminum Armored

780" Steel Interlocking Metal Clad Cable ; 780" Aluminum Interlocking Metal Clad Cable.

Standards: UL 514B CSA C22.2 No. 18 NEC Articles 350, 333 & 334

Teddico/BWF Pittsburgh, Pa. 15205 www.teddicobwf.com TECICIIICCD BWF ELECTRICAL PRODUCTS W

Use:Saddle connectors are used to terminate Armored

and Metal Clad Cables to a 1/2" knock-out in a dry

location box or enclosure.

• UL Listed Locknut

• End Stopped

Materials:• Zinc Die-Cast

Certification:E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18NEMA FB-1 NEC Articles 333 & 334

Saddle Connector BX • MC • FLEXCatalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

Boxed8460 08460-6 3/8" 0.90 1.61 0.93 50/500 35.4A

B

C

Use:Strap Connectors are used to terminate Armored

Cable and Metal Clad Cable to a steel outlet box

or metal enclosure.

Materials:• Zinc Die-Cast

Certification:E155411 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEC Articles 350, 333 & 334

Strap Connector BX • MC • FLEXCatalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

Boxed8464 08464-4 1/2" 1.40 1.80 0.40 25/250 25.6C

A

B

Trade Size For Cable Sizes

3/8" For 14-2 (nominal OD .465") through 10-3 (nominal OD .500") Steel Armored Cable;

For 14-2 (nominal OD .480") through 10-3 (nominal OD .585") Aluminum Armored

Cable.

For 0.475” through 0.600” Steel Interlocking Metal Clad Cable .

For 0.468” through 0.610” Aluminum Interlocking Metal Clad Cable.

For 12/2 through 10/3 Oval NMSE Cable.

Trade Size For Cable Sizes

1/2" For 8-4 (nominal OD .785") through 8-2 (nominal OD .680") Steel Armored Cable;

For 8-4 (nominal OD .780") through 8-2 (nominal OD .680") Aluminum Armored

Cable.

For 0.680” through 0.780” Steel Interlocking Metal Clad Cable ;

For 0.675” through 0.780” Aluminum Interlocking Metal Clad Cable.

Teddico/BWF Pittsburgh, Pa. 15205

FLEX

�M

C

�B

X

www.teddicobwf.com 2-5

Page 23: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

BX • M

C •

FLEX

Duplex Connector

Use: Duplex connectors are used to terminate two runs of Armored Cable, Metal Clad Cable or Flexible Metal Conduit to a 1/2" knock-out in a dry location box or enclosure.

• Clamp Type

• Double Screw Materials: • Zinc Die-Cast

Certification:

E155411 LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Articles 350, 333 & 334

Duplex Connector

;If

NO1/11' Use: Duplex connectors are used to terminate two runs of Armored Cable, Metal Clad Cable or Flexible Metal Conduit to a 1/2" knock-out in a dry location box or enclosure. • Clamp Type

• Single Screw

Materials: • Zinc Die-Cast Certification:

E155411 LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Articles 350, 333 & 334

BX • MC • FLEX Catalog UPC No Trade Ctn/Case Case Number 0-87115 Size Qty/Qty Wt.

Boxed 8243 08243-5 3/8" 25/250 26.6

Trade Size For Cable Sizes

3/8" For Regular Wall Steel or Aluminum Flexible Metal Conduit. For 14-2 (nominal OD .460") through 10-3 (nominal OD .500") Steel Armored Cable; For 14-2 (nominal OD .480") through 10-3 (nominal OD .580") Aluminum Armored Cable. For 14-2 (nominal OD .468") through 10-3 (nominal OD .610") Aluminum Interlocking Metal Clad Cable; 14-2 (nominal OD .470") through 10-3 (nominal OD .600") Steel Interlocking Metal Clad Cable.

BX • MC • FLEX Catalog

UPC No Trade Nominal Dimensions Ctn/Case Case Number

0-87115 Size A B C Qty/Qty Wt.

Boxed 8242 08242-8 3/8" 1.60 1.5 0.42 25/250 26.6

Trade Size

For Cable Sizes

3/8" For Regular Wall Steel or Aluminum Flexible Metal Conduit. For 14-2 (nominal OD .460") through 10-3 (nominal OD .500") Steel Armored Cable; For 14-2 (nominal OD .480") through 10-3 (nominal OD .580") Aluminum Armored Cable. For 14-2 (nominal OD .468") through 10-3 (nominal OD .610") Aluminum Interlocking Metal Clad Cable; 14-2 (nominal OD .470") through 10-3 (nominal OD .600") Steel Interlocking Metal Clad Cable.

ELECTRICAL ARC/DUCTS W N TE13131C113 MIFF www.teddicobwf.com

Teddico/BWF Pittsburgh, Pa. 15205

Use:Duplex connectors are used to terminate two runs

of Armored Cable, Metal Clad Cable or Flexible

Metal Conduit to a 1/2" knock-out in a dry location

box or enclosure.

• Clamp Type

• Single Screw

Materials:• Zinc Die-Cast

Certification:E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18

NEMA FB-1 NEC Articles 350, 333 & 334

Duplex Connector

AC

B

BX • MC • FLEXCatalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

Boxed8242 08242-8 3/8" 1.60 1.5 0.42 25/250 26.6

Trade Size For Cable Sizes

3/8" For Regular Wall Steel or Aluminum Flexible Metal Conduit.

For 14-2 (nominal OD .460") through 10-3 (nominal OD .500") Steel Armored Cable;

For 14-2 (nominal OD .480") through 10-3 (nominal OD .580") Aluminum Armored

Cable.

For 14-2 (nominal OD .468") through 10-3 (nominal OD .610")

Aluminum Interlocking Metal Clad Cable; 14-2 (nominal OD .470")

through 10-3 (nominal OD .600") Steel Interlocking Metal Clad

Cable.

MC

B

X

FLE

X�

Use:Duplex connectors are used to terminate two runs

of Armored Cable, Metal Clad Cable or Flexible

Metal Conduit to a 1/2" knock-out in a dry location

box or enclosure.

• Clamp Type

• Double Screw

Materials:• Zinc Die-Cast

Certification:E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18

NEMA FB-1 NEC Articles 350, 333 & 334

Duplex Connector BX • MC • FLEXCatalog UPC No Trade Ctn/Case Case

Number 0-87115 Size Qty/Qty Wt.

Boxed8243 08243-5 3/8" 25/250 26.6

Trade Size For Cable Sizes

3/8" For Regular Wall Steel or Aluminum Flexible Metal Conduit.

For 14-2 (nominal OD .460") through 10-3 (nominal OD .500") Steel Armored Cable;

For 14-2 (nominal OD .480") through 10-3 (nominal OD .580") Aluminum Armored

Cable.

For 14-2 (nominal OD .468") through 10-3 (nominal OD .610")

Aluminum Interlocking Metal Clad Cable; 14-2 (nominal OD .470")

through 10-3 (nominal OD .600") Steel Interlocking Metal Clad

Cable.

Teddico/BWF Pittsburgh, Pa. 15205www.teddicobwf.com2-6

Page 24: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

EMT To Flex Couplings

EMT (THINWALL) CONDUIT

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

Boxed

8217 08217-6 1/2"-3/8" 0.72 0.93 1.34 50/500 34.3 Use: Combination couplings are used to provide a transition from steel EMT conduit to Flexible Metal Conduit. • Set Screw - Clamp Type

Materials: • Zinc Die-Cast Certification:

® E210498 LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 348 & 350

Use: Combination couplings are used to provide a transition from steel EMT conduit to Flexible Metal Conduit. • Set Screw - Squeeze Type

Materials: • Zinc Die-Cast Certification:

® E210498 LR57925

EMT To Flex Couplings C

EMT (THINWALL) CONDUIT Catalog UPC No Trade Nominal Dimensions Ctn/Case Case Number 0-87115 Size A B C Qty/Qty Wt.

Boxed 8218 08218-3 1/2"-3/8" 0.72 0.93 1.34 50/500 34.3 8219 08219-0 1/2"-1/2" 0.93 0.94 1.62 25/250 21.9

BX • MC • FLEX

0

Catalog Number

UPC No

0-87115

Trade Size

Nominal Dimensions A B C

Ctn/Case Case

Qty/Qty Wt.

Boxed 8210 08210-7 1/2" 1.40 0.92 0.15 50/500 40.9

Use: 8211 08211-4 3/4" 1.52 1.12 0.20 25/250 30.8 Combination couplings are used to provide a transition from steel EMT Conduit to Flexible Metal Conduit. • Compression - Screw in Type

Materials: • Zinc Die-Cast Certification:

® E155411 e LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Articles 348 & 350

TECICIIICCD BWF www.teddicobwf.com

Teddico/BWF Pittsburgh, Pa. 15205 ELECTRICAL PRODUCTS W

Teddico/BWF Pittsburgh, Pa. 15205

FLEX

�M

C

�B

X

Use:Combination couplings are used to provide a

transition from steel EMT Conduit to Flexible Metal

Conduit.

• Compression - Screw in Type

Materials:• Zinc Die-Cast

Certification:E155411 LR57925

Standards:UL 514B CSA C22.2 No. 18

NEMA FB-1 NEC Articles 348 & 350

A

B A

/F

EMT To Flex CouplingsC

BX • MC • FLEXCatalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

Boxed8210 08210-7 1/2" 1.40 0.92 0.15 50/500 40.9

8211 08211-4 3/4" 1.52 1.12 0.20 25/250 30.8

Use:Combination couplings are used to provide a

transition from steel EMT conduit to Flexible Metal

Conduit.

• Set Screw - Squeeze Type

Materials:• Zinc Die-Cast

Certification:E210498 LR57925

EMT To Flex Couplings EMT (THINWALL) CONDUITCatalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

Boxed8217 08217-6 1/2"-3/8" 0.72 0.93 1.34 50/500 34.3

A B

C

AB

C

Use:Combination couplings are used to provide a

transition from steel EMT conduit to Flexible Metal

Conduit.

• Set Screw - Clamp Type

Materials:• Zinc Die-Cast

Certification:E210498 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 348 & 350

EMT (THINWALL) CONDUITCatalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

Boxed8218 08218-3 1/2"-3/8" 0.72 0.93 1.34 50/500 34.3

8219 08219-0 1/2"-1/2" 0.93 0.94 1.62 25/250 21.9

www.teddicobwf.com 2-7

Page 25: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Use: One hole straps are used to provide support for runs of Armored Cable.

Materials: • Galvanized Steel

• Zinc Plated

Snap-in Flex BX • MC • FLEX

50/500 37.5 9590 09590-9 1/2" 1.44 0.88

25/250 36 9591 09591-6 3/4" 1.69 1.31

9593 09593-0 1/2" 1.63 1.69 A

Use: Snap-in connectors are used to terminate Armored cable.

• No tools needed • Single unit construction eliminates

I oose component parts, integral green plastic insulated throat bushing provides maximum protection for wire installation

• No locknut required

Certification:

® E238299

Anti-Short Bushings BX • MC • FLEX

Teddico/BWF Pittsburgh, Pa. 15205 TE13131C113 134 ei'VF www.teddicobwf.com

ELECTRICAL ARDIDUCTS

09300-4 3/8" 1.27 0.5 0.47 100/1000 13.9

09301-1 1/2" 1.43 0.5 0.47 50/100 1.1

Boxed

A

BX • MC • FLEX

Boxed

Materials: • Steel

Catalog Number

UPC No 0-87115

Trade Size

Bag/Case

Qty/Qty Case Wt.

Polyberi 9265 09265-6 0 35/500 15 9266 09266-3 1 35/400 12 9267 09267-0 2 35/300 18 9268 09268-7 3 20/200 16

Use: 9269 09269-4 4 16/100 9 Anti-short bushings are inserted into the end of Armored Cable and Flexible Metal Conduit in order to protect the conductors from the sharp edges of the raceway where cut.

Materials: • Plastic

N B

X • M

C •

FL

EX

co

20/200 20.4

9300

9301

Boxed

BX One Hole Strap

N.:14, iv-

0

BX • MC • FLEX

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case Number 0-87115 Size A B C Qty/Qty Wt.

Use:One hole straps are used to provide support for

runs of Armored Cable.

Materials:• Galvanized Steel

• Zinc Plated

BX One Hole Strap BX • MC • FLEXCatalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

9300 09300-4 3/8" 1.27 0.5 0.47 100/1000 13.9

BoxedC

A

B

Use:Anti-short bushings are inserted into the end of

Armored Cable and Flexible Metal Conduit in order

to protect the conductors from the sharp edges of

the raceway where cut.

Materials:• Plastic

Anti-Short Bushings BX • MC • FLEXCatalog UPC No Trade Bag/Case Case

Number 0-87115 Size Qty/Qty Wt.

Polybag9265 09265-6 0 35/500 15

9266 09266-3 1 35/400 12

9267 09267-0 2 35/300 18

9268 09268-7 3 20/200 16

9269 09269-4 4 16/100 9

Teddico/BWF Pittsburgh, Pa. 15205

MC

FL

EX

��

BX

9301 09301-1 1/2" 1.43 0.5 0.47 50/100 1.1

Use:Snap-in connectors are used to terminate Armored

cable.

• No tools needed

Materials:• Steel

Snap-in Flex BX • MC • FLEXCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9590 09590-9 1/2" 1.44 0.88 - 50/500 37.5

A

B

9591 09591-6 3/4" 1.69 1.31 - 25/250 36

BX • MC • FLEXCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9593 09593-0 1/2" 1.63 1.69 - 20/200 20.4

• Single unit construction eliminatesl oose component parts, integral greenplastic insulated throat bushing providesmaximum protection for wire installation

• No locknut required

B

A

Certification:E238299

www.teddicobwf.com2-8

Page 26: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

NM / SE CABLE

LR57925

Service Entrance Cable Connectors

Catalog UPC No Trade Wire Ctn/Case Case

Number 0-87115 Size Size Qty/Qty Wt.

Boxed

8404 08404-0 1" 3#4 10/100 26 8406 08406-4 1" 3#6 10/100 25 8408 08408-8 1" 3#8 10/100 25 8411 08411-8 1 1/4" 3#1 10/50 26 8412 08412-5 1 1/4" 3#2 10/50 21 8413 08413-2 1 1/4" 3#3 10/50 52 8410 08410-1 1 1/2" 3#1/0 5/25 16 8420 08420-0 1 1/2" 3#2/0 5/25 23 8430 08430-9 2" 3#1/0 5/25 23 8431 08431-6 2" 3#2/0 5/50 45 8432 08432-3 2" 3#3/0 5/50 45 8440 08440-8 2" 3#4/0 5/25 23.5

* 8440-L 08417-0 2" 3#4/0 5/25 23.5

Use: Watertight connectors are used for sealing and terminating Oval Type SE or USE Cable to a threaded entry of a watertight box or enclosure. Materials: • Zinc Die-Cast Certification:

E155410 E213494 LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 338

OF Connectors NM / SE CABLE

* Large Grommet Opening

Catalog UPC No Trade Grommet Opening Wire Ctn/Case Case Number 0-87115 Size Minimum Maximum Size Qty/Qty Wt.

Boxed 8376 08376-0 1/2" .10 x .22 .44 x .47 12/2 25/250 24.3 8377 08377-7 3/4" .17 x .22 .66 x .80 12/3 25/250 38.3

Use: Used to connect underground feeder cable to a weather proof box with threaded hub. • For Underground Feeder Cable Only

Materials: • Zinc Die-Cast Certification:

E155411

Strain Relief Cord Connectors ACCESSORIES Catalog UPC No Trade Cord Nominal Dimensions Ctn/Case Case Number 0-31857 Size Range A B C Qty/Qty Wt.

Boxed

Use: Strain relief cord connectors are used to connect S, SO, ST, SJ, SJO and SJT cord to a steel outlet box or metal enclosure. • Rain-Tight

Materials • Zinc Die-Cast Certification

E121487 LR57925

8500 08500-9 1/2" .190-.260 1.19 0.26 0.38 8501 08501-6 1/2" .260-.375 1.19 0.38 0.38 8502 08502-3 1/2" .375-.500 1.19 0.5 0.38 8503 08503-0 3/4" .440-.500 1.29 0.5 0.40 8504 08504-7 3/4" .500-.625 1.29 0.63 0.40 8505 08505-0 3/4" .625-.725 1.29 0.75 0.40

25/250 44.9 25/250 23.9 25/250 23.0 25/250 66.9 25/250 67.2 25/250 67.2

TECICIIICCD BWF Teddico/BWF Pittsburgh, Pa. 15205 www.teddicobwf.com

ELECTRICAL PRODUCTS W

Use:Watertight connectors are used for sealing and

terminating Oval Type SE or USE Cable to a

threaded entry of a watertight box or enclosure.

Materials:• Zinc Die-Cast

Certification:E155410 E213494 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 338

Service Entrance CableConnectors

NM / SE CABLE

8404 08404-0

8406 08406-4

8408 08408-8

Boxed

For Underground Feeder Cable Only

Boxed1/2" .10 x .22 .44 x .47 12/2 25/250 24.3

3/4" .17 x .22 .66 x .80 12/3 25/250 38.3

Teddico/BWF Pittsburgh, Pa. 15205

NM

/SE

CA

BLE

8411 08411-8

8412 08412-58413 08413-2

8410 08410-1

8420 08420-0

8430 08430-98431 08431-6

8432 08432-3

8440 08440-8

8440-L 08417-0

NM / SE CABLEUF Connectors

Size Minimum Maximum Size

Use:Used to connect underground feeder cable

to a weather proof box with threaded hub.

Materials:• Zinc Die-Cast

Certification:E155411 LR57925

8376 08376-0

8377 08377-7

1 1/4" 3#2

1 1/4" 3#1

Trade Wire

Size Size

1" 3#4

1" 3#6

1" 3#8

1 1/4" 3#3

1 1/2" 3#1/0

1 1/2" 3#2/0

2" 3#1/0

2" 3#2/0

2" 3#3/0

2" 3#4/0

Ctn/Case Case

Qty/Qty Wt.

10/100

10/100

10/100

10/50

10/50

10/50

5/25

5/25

5/25

5/50

5/50

5/25

5/253#4/02"

26

25

25

26

21

52

16

23

23

45

45

23.5

23.5

www.teddicobwf.com

Catalog UPC No Trade Grommet Opening Wire Ctn/Case Case

Number 0-87115 Qty/Qty Wt.

Catalog UPC No

Number 0-87115

3-1

*

* Large Grommet Opening

Use:Strain relief cord connectors are used to connect

S, SO, ST, SJ, SJO and SJT cord to a steel outlet

box or metal enclosure.

• Rain-Tight

• Zinc Die-Cast

Certification E121487 LR57925

Strain Relief Cord Connectors ACCESSORIES

Boxed

A

C

B

Materials

Catalog UPC No Trade Cord Nominal Dimensions Ctn/Case CaseNumber 0-31857 Size Range A B C Qty/Qty Wt.

8500 08500-9 1/2" .190-.260 1.19 0.26 0.38 25/250 44.9

8501 08501-6 1/2" .260-.375 1.19 0.38 0.38 25/250 23.9

8502 08502-3 1/2" .375-.500 1.19 0.5 0.38 25/250 23.0

8503 08503-0 3/4" .440-.500 1.29 0.5 0.40 25/250 66.9

8504 08504-7 3/4" .500-.625 1.29 0.63 0.40 25/250 67.2

8505 08505-0 3/4" .625-.725 1.29 0.75 0.40 25/250 67.2

Page 27: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Mini One Hole Straps NM / SE CABLE

100/1000 14.0 9305 09305-9 14/2,12/2 1.08 0.50 0.30

www.teddicobwf.com TE©DICD idett. ELECTRICAL ARC/DUCTS

Teddico/BWF Pittsburgh, Pa. 15205

Use: Midget one hole straps are used to secure bare solid copper wire to a working surface.

Materials • Stamped Steel

• Zinc Plated

One mole Romex Strap NM / SE CABLE

Use: Midget one hole straps are used to secure bare solid copper wire to a working surface.

Materials • Stamped Steel

• Zinc Plated

One Hole SEU Straps

Use: One hole straps are used to secure Type SE or USE Service Entrance Cable.

Materials • Stamped Steel

• Zinc Plated

Two Hole SEU Straps

Use: Two hole straps are used to secure Type SE or USE Service Entrance Cable.

Materials • Stamped Steel

• Zinc Plated

NM / SE CABLE

Boxed 9250 09250-2 3#8,6,4 1.39 0.50 0.35 100/1000 14.3 9251 09251-9 3#3,2 1.69 0.56 0.44 100/1000 20.6 9252 09252-6 3#1,1/0,2/0 1.94 0.56 0.56 25/250 23.6 9253 09253-3 3#3/0,4/0 2.50 1.00 0.84 25/250 22.5

NM / SE CABLE

Boxed 9254 09254-0 3#8,6,4 2.38 0.75 0.38 100/1000 30.0 9255 09255-0 3#3,2 2.75 0.75 0.50 100/1000 34.9 9256 09256-4 3#1/0,2/0 3.19 0.75 0.75 25/250 12.8 9257 09257-1 3#3/0-4/0 3.50 0.75 0.81 25/250 13.9

NM

/SE

CA

BL

E

N

Boxed 9258 09258-8 3/16" OD 0.69 0.32 0.19 100/1000 3.4 9259 09259-5 1/4" OD 0.99 0.50 0.23 100/1000 6.5

Boxed

Catalog UPC No Wire Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Use:Midget one hole straps are used to secure bare

solid copper wire to a working surface.

Materials • Stamped Steel

• Zinc Plated

Mini One Hole Straps NM / SE CABLE

Boxed9258 09258-8 3/16" OD 0.69 0.32 0.19 - 100/1000 3.4

9259 09259-5 1/4" OD 0.99 0.50 0.23 - 100/1000 6.5B

C

A

Use:One hole straps are used to secure Type SE or

USE Service Entrance Cable.

Materials • Stamped Steel

• Zinc Plated

One Hole SEU Straps NM / SE CABLECatalog UPC No Wire Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9250 09250-2 3#8,6,4 1.39 0.50 0.35 - 100/1000 14.3

9251 09251-9 3#3,2 1.69 0.56 0.44 - 100/1000 20.6

9252 09252-6 3#1,1/0,2/0 1.94 0.56 0.56 - 25/250 23.6

9253 09253-3 3#3/0,4/0 2.50 1.00 0.84 - 25/250 22.5

B

C A

Use:Two hole straps are used to secure Type SE or

USE Service Entrance Cable.

Materials • Stamped Steel

• Zinc Plated

Two Hole SEU Straps NM / SE CABLECatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9254 09254-0 3#8,6,4 2.38 0.75 0.38 - 100/1000 30.0

9255 09255-0 3#3,2 2.75 0.75 0.50 - 100/1000 34.9

9256 09256-4 3#1/0,2/0 3.19 0.75 0.75 - 25/250 12.8

9257 09257-1 3#3/0-4/0 3.50 0.75 0.81 - 25/250 13.9

B

C

A

Teddico/BWF Pittsburgh, Pa. 15205

NM

/SE

CA

BLE

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

www.teddicobwf.com3-2

Use:Midget one hole straps are used to secure bare

solid copper wire to a working surface.

Materials • Stamped Steel

• Zinc Plated

One Hole Romex Strap NM / SE CABLE

Boxed9305 09305-9 14/2,12/2 1.08 0.50 0.30 - 100/1000 14.0

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

B

C A

Page 28: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Clamp On Service Entrance Heads

NM / SE CABLE Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed 180 70905-9 1/2" 2.25 2.22 1.93 181 70910-3 3/4" 2.48 2.51 2.20 182 70915-8 1" 2.75 2.85 2.55 183 70920-2 1 1/4" 3.12 2.90 2.98 184 70925-7 1 1/2" 3.75 3.68 3.18 185 70930-1 2" 4.34 5.28 4.61 1866 70935-6 21/2" 5.64 5.52 5.20 2877 70932-5 3" 6.39 6.25 5.26 2888 70945-5 31/2" 6.82 6.85 7.16 2899 70950-9 4" 7.65 6.85 7.25

50 24 50 24 25 10 25 14 15 13 5 8 1 4.5 1 7 1 6.5 1 6.5

Service entrance caps are used as a connecting point in an overhead service entrance and can be mounted on threaded or unthreaded Rigid Conduit, IMC or EMT Conduit. • Clamp-On Type

• Phenolic Insulator with Multiple Holes

• Listed for Use in Wet Locations

Materials • Aluminum Die-Cast Certification

E121487 LR57925

Standards UL 514B CSA C22.2 No. 18 NEC Articles 345, 346 & 348

Threaded Service Entrance Heads

NM / SE CABLE Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Use: Service entrance caps are used as a connecting point in an overhead service entrance and can be mounted on threaded Rigid Conduit and IMC. • Threaded Type • Phenolic Insulator with Multiple Holes • Listed for Use in Wet Locations

Materials • Aluminum Die-Cast Certification

E121487 LR57925

Boxed 8160 08160-5 1/2" 0.97 2.19 2.04 8161 08161-2 3/4" 1.16 2.41 2.13 8162 08162-9 1" 1.51 2.83 2.54 8163 08163-6 1 1/4" 1.89 2.89 3.00 8164 08164-3 1 1/2" 2.16 3.51 3.20 8165 08165-0 2" 2.70 4.36 4.58

5/50 5/25 10 10 10 5

15 8.8 4.8 5.2 5.2 7.7

Standards UL 514B CSA C22.2 No. 18 NEC Articles 345, 346 & 348

TECICIIICCD BWF www.teddicobwf.com

Teddico/BWF Pittsburgh, Pa. 15205 ELECTRICAL PRODUCTS W

Use:Service entrance caps are used as a connectingpoint in an overhead service entrance and can bemounted on threaded or unthreaded RigidConduit, IMC or EMT Conduit. • Clamp-On Type

• Phenolic Insulator with Multiple Holes

• Listed for Use in Wet Locations

Materials • Aluminum Die-Cast

Certification E121487 LR57925

StandardsUL 514B CSA C22.2 No. 18NEC Articles 345, 346 & 348

Service Entrance Heads

NM / SE CABLECatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed180 70905-9 1/2" 2.25 2.22 1.93 - 50 24

181 70910-3 3/4" 2.48 2.51 2.20 - 50 24

182 70915-8 1" 2.75 2.85 2.55 - 25 10

183 70920-2 1 1/4" 3.12 2.90 2.98 - 25 14

184 70925-7 1 1/2" 3.75 3.68 3.18 - 15 13

185 70930-1 2" 4.34 5.28 4.61 - 5 8

1866 70935-6 2 1/2" 5.64 5.52 5.20 - 1 4.5

2877 70932-5 3" 6.39 6.25 5.26 - 1 7

2888 70945-5 3 1/2" 6.82 6.85 7.16 - 1 6.5

2899 70950-9 4" 7.65 6.85 7.25 - 1 6.5

A

B

C

Use:Service entrance caps are used as a connectingpoint in an overhead service entrance and can be

• Threaded Type• Phenolic Insulator with Multiple Holes• Listed for Use in Wet Locations

Materials • Aluminum Die-Cast

Certification E121487 LR57925

StandardsUL 514B CSA C22.2 No. 18NEC Articles 345, 346 & 348

Service Entrance Heads

NM / SE CABLECatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8160 08160-5 1/2" 0.97 2.19 2.04 - 5/50 15

8161 08161-2 3/4" 1.16 2.41 2.13 - 5/25 8.8

8162 08162-9 1" 1.51 2.83 2.54 - 10 4.8

8163 08163-6 1 1/4" 1.89 2.89 3.00 - 10 5.2

8164 08164-3 1 1/2" 2.16 3.51 3.20 - 10 5.2

8165 08165-0 2" 2.70 4.36 4.58 - 5 7.7

A

B

C

Teddico/BWF Pittsburgh, Pa. 15205

NM

/SE

CA

BLE

Clamp On

Threaded

www.teddicobwf.com

mounted on threaded Rigid Conduit and IMC.

3-3

Page 29: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Oval Service Cable Heads NM / SE CABLE Catalog Number

UPC No 0-87115

Boxed 9364 09364-6 9365 09365-3

Trade Nominal Dimensions Pcs/ Ctn/Case Case Size A B C Unit Qty/Qty Wt.

3#8-3#1 3.47 1.90 2.80 5 1.4 3#1/0-3#4/0 4.90 2.90 4.30 5 3.3

Service Entrance Mast Heads

NM / SE CABLE Catalog Number

UPC No 0-87115

Pipe Size

Head size

Nominal Dimensions A B C

Pcs/ Unit

Ctn/Case Qty/Qty

Case

Wt. m Boxed

9366 09366-0 2" 1 1/4" 2.66 3.72 3.14 - 4 3 9367 09367-7 21/2" 11/4" 3.28 4.05 3.08 - 2 2 9368 09368-4 21/2" 2" 3.12 4.57 4.20 - 2 2

NM

/SE

CA

BL

E

41! Service entrance caps are used as a connecting point in an overhead service entrance and can be mounted on threaded or unthreaded Rigid Conduit, IMC or EMT Conduit. • Slip Fit

• Phenolic Insulator with Multiple Holes

• Listed for Use in Wet Locations

Materials • Aluminum Die-Cast

Certification

® E121487 LR57925

Standards UL 514B CSA C22.2 No. 18 NEC Articles 345, 346 & 348

Die-cast oval service entrance caps are used as a connecting point in an overhead service entrance for SEU Cable. • Removable Cap

• 2-Piece Phenolic Insulator

• Listed for Use in Wet Locations

Materials: • Aluminum Die-Cast Certification:

® E155410

'cards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 338

• LR57925

Teddico/BWF Pittsburgh, Pa. 15205 www.teddicobwf.com TE©DICD idett. ELECTRICAL ARC/DUCTS

Use:Service entrance caps are used as a connecting

point in an overhead service entrance and can be

mounted on threaded or unthreaded Rigid

Conduit, IMC or EMT Conduit.

• Slip Fit

• Phenolic Insulator with Multiple Holes

• Listed for Use in Wet Locations

Service Entrance Mast Heads

NM / SE CABLE

A

B

C

Catalog UPC No Pipe Head Nominal Dimensions Pcs/ Ctn/Case CaseNumber 0-87115 Size size A B C Unit Qty/Qty Wt.

Boxed9366 09366-0 2" 1 1/4" 2.66 3.72 3.14 - 4 3

9367 09367-7 2 1/2" 1 1/4" 3.28 4.05 3.08 - 2 2

9368 09368-4 2 1/2" 2" 3.12 4.57 4.20 - 2 2

NM / SE CABLECatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9364 09364-6 3#8-3#1 3.47 1.90 2.80 - 5 1.4

9365 09365-3 3#1/0-3#4/0 4.90 2.90 4.30 - 5 3.3

Use:Die-cast oval service entrance caps are used as a

connecting point in an overhead service entrance

for SEU Cable.

• Removable Cap

• 2-Piece Phenolic Insulator

• Listed for Use in Wet Locations

Materials:• Aluminum Die-Cast

Certification:E155410 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 338

Oval Service Cable Heads

A

B

C

Teddico/BWF Pittsburgh, Pa. 15205

NM

/SE

CA

BLE

Materials • Aluminum Die-Cast

Certification E121487 LR57925

StandardsUL 514B CSA C22.2 No. 18NEC Articles 345, 346 & 348

www.teddicobwf.com3-4

Page 30: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

B

PVC Service Entrance Heads NM / SE CABLE Catalog UPC No Trade Ctn/Case Case

Number 0-87115 Size Qty/Qty Wt.

Boxed 7200 7201 7202 7203 7204

7205

70200-9 70201-6 70202-3 70203-0 70204-7

70205-4

1/2" 25 6.70 3/4" 25 17.5 1" 20 22.0 1 1/4" 10 14.0 1 1/2" 10 13.0 2" 5 8.0 Service entrance caps are used as a connecting

point in an overhead service entrance and can be mounted on threaded or unthreaded Rigid, IMC, PVC or EMT Conduits.

• For Rigid, IMC, PVC & EMT (adaptor sleeve included)

• Supplied with screw and nut • Rigid, weather-resistant design

• Acts as an insulator of high dielectric strength • Meets UL & CSA specifications

Materials: • Plastic

E161187

203DIA. / SCREW HOLE i___ c

*Dimension " G" conforms to UL specs for metallic conduit. Adapter sleeve included for EMT.

Box Number Size C D E F G* H J Oty. Pa Nomura Dimensions

7200 1/2" 2 2.718 1.5 1.968 0.687 0.937 0.855 2.609 0.312 25 7201 3/4" 2.406 2.296 1.718 2.234 0.812 0.937 1.065 1.25 0.437 25 7202 1" 2.406 2.296 1.968 2.234 0.812 1.125 1.33 1.312 0.437 20 7203 1 1/4" 3.031 4.031 2.343 2.656 0.875 1.093 1.675 1.89 0.531 10 7204 1 1/2" 2.406 2.296 1.968 2.234 0.812 1.125 1.33 1.312 0.437 10 7205 2" 3.031 4.031 2.343 2.656 0.875 1.093 1.675 1.89 0.531 5

PVC Oval Service Cable Heads NM / SE CABLE Part UPC No Nominal Dimensions Box

Number 0-87115 Size A B C D E F G Qty.

7206 07206-1 #8, 6, 4, 2 2 2.718 1.343 1.125 0.687 0.531 1.968 30 7207 07207-8 1/0,2/0 3.031 4.031 1.75 1.375 1.125 0.687 2.875 10 7208 07208-5 3/0,4/0 3.031 4.031 2.125 1.625 1.125 0.687 2.875 10

Use: PVC oval service entrance caps are used as a connecting point in an overhead service entrance for SEU Cable.

• Accommodates 3-conductor No. 8 AWG to 3-conductor No. 4/0 AWG cables

• Supplied with screw and nut • Rigid, weather-resistant material • Galvanized back plate for easy installation

• Meets UL specifications

Material • Plastic

E36810

TEDDICD BWF www.teddicobwf.com Teddico/BWF Pittsburgh, Pa. 15205 ELECTRICAL PRODUCTS W

Use:PVC oval service entrance caps are used as a

connecting point in an overhead service entrance

for SEU Cable.

Materials:• Plastic

PVC Oval Service Cable Heads NM / SE CABLE

Use:Service entrance caps are used as a connecting

point in an overhead service entrance and can be

mounted on threaded or unthreaded Rigid, IMC,

PVC or EMT Conduits.

Materials:• Plastic

PVC Service Entrance Heads NM / SE CABLE

NM

/SE

CA

BLE

2.406 2.296 1.718 2.234 0.812 0.937 1.065 1.25 0.437

2.406 2.296 1.968 2.234 0.812 1.125 1.33 1.312 0.437

3.031 4.031 2.343 2.656 0.875 1.093 1.675 1.89 0.531

2.406 2.296 1.968 2.234 0.812 1.125 1.33 1.312 0.437

3.031 4.031 2.343 2.656 0.875 1.093 1.675 1.89 0.531

7200 2 2.718 1.5 1.968 0.687 0.937 0.855 2.609 0.3121/2"

7201 3/4"

7202 1"

7203 1 1/4"

7204 1 1/2"

7205 2"

Number Size Qty. Part Box

A B C D E F G* H J Nominal Dimensions

Part BoxNominal Dimensions

3.031 4.031 1.75 1.375 1.125 0.687 2.875 1/0,2/0

3.031 4.031 2.125 1.625 1.125 0.687 2.8753/0,4/0

2525

20

10

105

7206

7207

7208

30

10

10

• For Rigid, IMC, PVC & EMT (adaptor sleeve included)• Supplied with screw and nut• Rigid, weather-resistant design• Acts as an insulator of high dielectric strength• Meets UL & CSA specifications

*Dimension “G” conforms to UL specs for metallic conduit. Adapter sleeve included for EMT.

E161187

• Accommodates 3-conductor No. 8 AWG to 3-conductor No. 4 /0 AWG cables• Supplied with screw and nut• Rigid, weather-resistant material• Galvanized back plate for easy installation• Meets UL specifications

E36810

Teddico/BWF Pittsburgh, Pa. 15205www.teddicobwf.com

#8, 6, 4, 2

A B C D E F G Qty.

2 2.718 1.343 1.125 0.687 0.531 1.968

Number Size UPC No

0-87115

07206-1

07207-8

07208-5

3-5

Boxed

Ctn/Case Case

Qty/Qty Wt.

25 6.70

25 17.5

20 22.0

10 14.0

10 13.05 8.0

Catalog UPC No Trade

Number 0-87115 Size

7200 70200-9 1/2"

7201 70201-6 3/4"

7202 70202-3 1"

7203 70203-0 1 1/4"

7204 70204-7 1 1/2"

7205 70205-4 2"

Page 31: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Roof Fleshings

I

Use: Roof fleshings are used to provide a watertight seal in overhead services where the conduit mast penetrates the roofs surface.

Materials: • Neoprene

NM / SE CABLE Catalog UPC No Trade Base Ctn/Case Case Number 0-87115 Size Size Qty/Qty Wt.

Boxed 7119* 07119-4 1 1/2",2",3" 8 7/8"x11 3/4" 10 10.0 7120 07120-0 4" 8 7/8"x11 3/4" 10 10.0

*Indicates Combo unit that can be used for all 3 sizes.

Service Cable Sill Plates

Use: Sill plates are used in conjunction with sealing compound to protect service entrance cable and to cover the hole where it enters the dwelling. • Covers service cable where it bends to

enter the building for an attractive finish

• May be used on all cable sizes from three #4 to three #0

• Unaffected by seasonal temperature extremes

Materia • PVC

Service Entrance Ells

NM / SE CABLE Catalog Number

UPC No 0-87115

Nominal Dimensions Box Qty. A B C D E F G* H I

Boxed 7210 07210-8 2.187 0.968 0.750 3.093 1.406 1.093 2.968 0.078 25° 10/100

.209 DIA. 2 HOLES

Service entrance ells are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance. • Listed for Use in Wet Location

Materials: • Aluminum Die Cast

Certification:

E121488 LR57925

Standards: UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Articles 345 & 346

Type SLB - Aluminum Conduit Entrance Ells

Cover,

BWF#

asket & screws included, for ri . id conduit

Unit UPC Conduit 0-87115 Size

Description Type Color

Case Qty.

Case Weight

Boxed 500 75005 - 1 1/2" SLB Threaded Grey 38 8 501 75010-5 3/4" SLB Threaded Grey 36 8 502 75015-0 1" SLB Threaded Grey 12 6 503 75020-4 1-1/4" SLB Threaded Grey 12 11.5 504 75025-9 1-1/2" SLB Threaded Grey 10 10 505 75030-3 2" SLB Threaded Grey 4 5.5

503-XL 71035-2 1-1/4" XLSLB Threaded Grey 5 6 505-XL 71040-6 2" XLSLB Threaded Grey 5 14

TEDDICD mow fi I HirrkL 1F-1E-11 1L 117.

www.teddicobwf.com Teddico/BWF Pittsburgh, Pa. 15205

Service Cable Sill Plates NM / SE CABLE

Boxed

NM

/SE

CA

BLE

Type SLB – Aluminum Conduit Entrance EllsCover, gasket & screws included, for rigid conduit

BWF# Unit UPC Conduit Description Case Case 0-87115 Size Type Color Qty. Weight

500 75005-1 1/2” SLBThreaded Grey 38 8501 75010-5 3/4” SLBThreaded Grey 36 8502 75015-0 1” SLBThreaded Grey 12 6503 75020-4 1-1/4” SLBThreaded Grey 12 11.5504 75025-9 1-1/2” SLBThreaded Grey 10 10505 75030-3 2” SLBThreaded Grey 4 5.5

Boxed

503-XL 71035-2 1-1/4” XLSLBThreaded Grey 5 6505-XL 71040-6 2” XLSLBThreaded Grey 5 14

Number Qty.Catalog Box

A B C D E F G* H INominal DimensionsUPC No

0-87115

Use:Sill plates are used in conjunction with sealing

compound to protect service entrance cable and

to cover the hole where it enters the dwelling.• Covers service cable where it bends to enter the building for an attractive finish• May be used on all cable sizes from three #4 to three #0• Unaffected by seasonal temperature extremesMaterials:• PVC

• Listed for Use in Wet Location

Service entrance ells are used

to gain access to the interior of

a raceway for wire pulling, inspection

and maintenance.

Use:

Materials:• Aluminum Die Cast

Certification:E121488 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Articles 345 & 346

Service Entrance Ells

7210 07210-8 2.187 0.968 0.750 3.093 1.406 1.093 2.968 0.078 25° 10/100

3-6 Teddico/BWF Pittsburgh, Pa. 15205www.teddicobwf.com

Use:Roof flashings are used to provide a watertightseal in overhead services where the conduit mastpenetrates the roofs surface.

Materials:• Neoprene

Roof Flashings NM / SE CABLECatalog UPC No Trade Base Ctn/Case Case

Number 0-87115 Size Size Qty/Qty Wt.

Boxed7119* 07119-4 1 1/2",2",3" 8 7/8"x11 3/4" 10 10.0

7120 07120-0 4" 8 7/8"x11 3/4" 10 10.0

*Indicates Combo unit that can be used for all 3 sizes.

DISCONTINUED

Page 32: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Boxed 7500 07500-0 2-1/4" Lag 5.26 1.54 2.50 50

Use: Conduit supports are used to secure Service Entrance Conduit to the outside surface of a building. • 1/2" x 10" Stud Bolt

Materials: • Steel

Heavy Duty Porcelain Wireholders NM / SE CABLE Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-31857 Size A B C Unit Qty/Qty Wt.

35.5 Use: Porcelain wireholders are used in overhead services to support and secure incoming service entrance wires prior to entrance. • Reinforced

• Porcelain • Steel

Adjustable Wireholder NM / SE CABLE Catalog UPC No Nominal Dimensions Pcs/ Ctn/Case Case Number 0-31857 A B C Unit Qty/Qty Wt.

Boxed 7501 Use:

Porcelain wireholders are used in overhead services to support and secure incoming service entrance wires prior to entrance. • Clamp-On • Mounts Below Service Entrance Cap

Materials / Materiales : • Porcelain • Steel

07503-1 2.80 1.70 3.37 20 30.4

Standard Porcelain Wireholders NM / SE CABLE Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-31857 Size A B C Unit Qty/Qty Wt.

Boxed 10/100 28.0 7502 07505-0 1-11/16" 3.88 1.44 2.13

7503 07506-2 2-1/4" 4.80 1.95 2.64

Use: Porcelain wireholders are used in overhead services to support and secure incoming service entrance wires prior to entrance.

Materials: • Porcelain

• Steel

50 30.5

Universal Conduit Supports

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-31857 Size A B C Unit Qty/Qty Wt.

Boxed

NM / SE CABLE

7504 07509-3 1 1/4"-3" 5.36 4.10 0.15 20 7.7

TE131311CCI mr. ELECTRICAL PFICCLICTS

www.tedd icobwf.com Teddico/BWF Pittsburgh, Pa. 15205

NM

/SE

CA

BLE

Use:Porcelain wireholders are used in overheadservices to support and secure incoming serviceentrance wires prior to entrance.• Reinforced

Materials:• Porcelain

• Steel

Heavy Duty Porcelain Wireholders NM / SE CABLECatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-31857 Size A B C Unit Qty/Qty Wt.

Boxed7500 07500-0 2-1/4" Lag 5.26 1.54 2.50 - 50 35.5

AC

B

Use:Porcelain wireholders are used in overhead

services to support and secure incoming service

entrance wires prior to entrance.

• Clamp-On

• Mounts Below Service Entrance Cap

Materials / Materiales :• Porcelain• Steel

Adjustable Wireholder NM / SE CABLE

Boxed7501 07503-1 2.80 1.70 3.37 - 20 30.4

A

B

C

Use:Porcelain wireholders are used in overhead

services to support and secure incoming service

entrance wires prior to entrance.

Materials:• Porcelain

• Steel

Standard Porcelain Wireholders NM / SE CABLECatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-31857 Size A B C Unit Qty/Qty Wt.

Boxed7502 07505-0 1-11/16" 3.88 1.44 2.13 - 10/100 28.0

7503 07506-2 2-1/4" 4.80 1.95 2.64 - 50 30.5

A

C

B

Catalog UPC No Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-31857 A B C Unit Qty/Qty Wt.

Use:Conduit supports are used to secure ServiceEntrance Conduit to the outside surface of a building.• ½" x 10" Stud Bolt

Materials:• Steel

Universal Conduit Supports NM / SE CABLECatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-31857 Size A B C Unit Qty/Qty Wt.

Boxed7504 07509-3 1 1/4"-3" 5.36 4.10 0.15 - 20 7.7

AB

C

3-7Teddico/BWF Pittsburgh, Pa. 15205www.teddicobwf.com

Page 33: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Clamp Type Connectors (NM Sheathed)

Use: 2-Piece clamp type connectors are used to terminate one or more Nonmetallic Sheathed Cables to a knock-out in a dry location box or enclosure. Also used in old work locations. • No Locknut Required • Butterfly Style

Materials: • Steel

NM / SE CABLE

Catalog Number

UPC No

0-87115

Trade Size

Nominal Dimensions A B C

Pcs/ Ctn/Case Case Unit Qty/Qty Wt.

Boxed 8470 08470-5 3/8" 0.80 1.17 0.39 100/1000 47.8 8471 08471-2 3/4" 0.94 1.67 0.42 50/500 44.1 8472 08472-9 1" 1.12 1.95 0.44 25/250 34.9 8473 08473-6 1 1/4" 2.25 1.31 0.60 10/100 28.1 8474 08474-3 11/2" 2.87 1.33 0.60 5/50 19.0 8475 08475-0 2" 3.50 1.57 0.74 10/40 21.5

Boxed 8366 08366-1 1 1/4" 1.25 2.18 0.61 10/100 19.0 8367 08367-8 1 1/2" 1.44 2.61 0.64 25 21.5 8368 08368-5 2" 1.59 2.95 0.78 5/25 21.5

Clamp Type Connectors (Oval Type SE)

v77114,, ,, Clamp type connectors are used to terminate Nonmetallic Sheathed and Oval Type SE or USE Cables to a knock-out in a dry location box or enclosure. • UL Listed Locknut

• Male Hub Threads NPS

Materials: • Zinc Die-Cast

Trade Size 3/8"

3/4"

1"

1 1/4" 1 1/2" Certification:

®E213494 / E155410 LR57925

Standard UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Articles 336 & 338

2-Piece connectors A

For Cable Sizes For one or two 14-2 to 12-2 Nonmetallic Sheathed Cables or one 0.29" to 0.45" diameter Flexible Cord. For 10-3 to 8-2 Nonmetallic Sheathed and 8-3 to 4-3 Oval Service Entrance Cable and 8-3 to 6-3 Round Service Entrance Cable. For 10-3 to 4-3 Nonmetallic Sheathed and 6-3 to 4-3 Oval Service Entrance Cable and 6-3 to 2-3 Round Service Entrance Cable 4-3 to 2-3 Nonmetallic Sheathed and 1.19" Service Entrance Cable. For 1.48" Service Entrance Cable.

NM / SE CABLE Catalog

UPC No Trade Nominal Dimensions Ctn/Case Case Number

0-87115 Size A B C Qty/Qty Wt.

Boxed 9245 09245-8 1/2" 1.312 0.95 0.65 100/1000 55.0 9246 09246-5 3/4"-1" 1.75 1.25 0.76 50/500 39.5 9247 09247-2 1 1/4" 2.125 1.63 0.76 100/1000 55.0 9248 09248-9 1 1/2" 2.50 1.97 0.79 50/500 39.5

3-8

TE131311C113 BINF Teddico/BWF Pittsburgh, Pa. 15205

ELECTRICAL PRODUCTS W

NM / SE CABLE

Teddico/BWF Pittsburgh, Pa. 15205

Use:Clamp type connectors are used to terminate

Nonmetallic Sheathed and Oval Type SE or USE

Cables to a knock-out in a dry location box or

enclosure.

• UL Listed Locknut

• Male Hub Threads NPS

Materials:• Zinc Die-Cast

Certification:E213494 / E155410 LR57925

Standards:UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Articles 336 & 338

Clamp Type ConnectorsCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8470 08470-5 3/8" 0.80 1.17 0.39 - 100/1000 47.8

8471 08471-2 3/4" 0.94 1.67 0.42 - 50/500 44.1

8472 08472-9 1" 1.12 1.95 0.44 - 25/250 34.9

8473 08473-6 1 1/4" 2.25 1.31 0.60 - 10/100 28.1

8366 08366-1 1 1/4" 1.25 2.18 0.61 - 10/100 19.0

8367 08367-8 1 1/2" 1.44 2.61 0.64 - 25 21.5

AC

B

B

CA

Trade Size For Cable Sizes3/8" For one or two 14-2 to 12-2 Nonmetallic Sheathed Cables or one 0.29" to 0.45"

diameter Flexible Cord.3/4" For 10-3 to 8-2 Nonmetallic Sheathed and 8-3 to 4-3 Oval Service Entrance Cable

and 8-3 to 6-3 Round Service Entrance Cable.1" For 10-3 to 4-3 Nonmetallic Sheathed and 6-3 to 4-3 Oval Service Entrance Cable

and 6-3 to 2-3 Round Service Entrance Cable

1 1/4" 4-3 to 2-3 Nonmetallic Sheathed and 1.19” Service Entrance Cable.

1 1/2" For 1.48” Service Entrance Cable.

NM

/SE

CA

BLE

Boxed

(NM Sheathed)

Clamp Type Connectors(Oval Type SE)

3-8

Use:2-Piece clamp type connectors are used toterminate one or more Nonmetallic SheathedCables to a knock-out in a dry location box orenclosure. Also used in old work locations. • No Locknut Required• Butterfly Style

Materials:• Steel

2-Piece connectors NM / SE CABLE

Boxed9245 09245-8 1/2" 1.312 0.95 0.65 - 100/1000 55.0

9246 09246-5 3/4"-1" 1.75 1.25 0.76 - 50/500 39.5

B

C

A

9247 09247-2 1 1/4" 2.125 1.63 0.76 - 100/1000 55.0

9248 09248-9 1 1/2" 2.50 1.97 0.79 - 50/500 39.5

Ctn/Case Case

Qty/Qty Wt.

Catalog UPC No Trade Nominal Dimensions

Number 0-87115 Size A B C

8474 08474-3 1 1/2" 2.87 1.33 0.60 - 5/50 19.0

8475 08475-0 2" 3.50 1.57 0.74 - 10/40 21.5

8368 08368-5 2" 1.59 2.95 0.78 - 5/25 21.5

Page 34: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Plastic Nonmetallic Cable Connectors

Use: Plastic nonmetallic cable connectors are used to terminate Nonmetallic Sheathed Cable to knockout in a dry location box or enclosure.

• Snap-In One Piece Construction

• Wide Variety of Cable Configurations

Materials: • Plastic

Plastic Nonmetallic Cable Connectors

NM / SE CABLE Catalog UPC No Trade

Ctn/Case Case

Number 0-87115 Size

Qty/Qty Wt.

Boxed 7117 07117-0 3/8"-1/2" 100/1000 7.0

Trade Size

3/8"

One Cable

(1) 14/2 -10/2 (1) 14/3- 10-3

Two Cables

(2) 14/2- 10/2 (1) 14/2 & 12/2 (1) 14/2 & 10/2 (1) 12/2 & 10/2

NM / SE CABLE

Catalog

UPC No Trade Nominal Dimensions

Ctn/Case Case Number

0-31857 Size A B CD E Qty/Qty Wt.

E-EA

7i014

--7 I7_

Boxed

7118 07118-7 1/2" 1.34 2.42 .834 .883 .825 50/250

8.1

h s

B

Use: Plastic nonmetallic cable connectors are used to terminate Nonmetallic Sheathed Cable or Flexible Cord to knockout in a dry location box or enclosure.

• Snap-In One Piece Construction

• Wide Variety of Cable Configurations

• Plastic

SW E66712

• Accommodates one or two 4-2,14-3 and 12-2 cables, one 12-3,10-2 and 10-3 cable, and one or two .300 inch or .600 inch diameter cords

• Push-in design with a captive lock wedge that secures cable with a single squeeze from standard electrician's pliers

• Excellent insulation, superior strain relief

• Sized to fit 1/2 inch (12.70mm) knockout size

TEDDICD BWF Teddico/BWF Pittsburgh, Pa. 15205

ELECTFIICAL PRODUCTS .IMM.rm,

Use:Plastic nonmetallic cable connectors are used to

terminate Nonmetallic Sheathed Cable to

knockout in a dry location box or enclosure.

• Snap-In One Piece Construction

• Wide Variety of Cable Configurations

Materials:• Plastic

Plastic Nonmetallic CableConnectors

NM / SE CABLE

Boxed7117 07117-0 3/8"-1/2" 100/1000 7.0

Use:Plastic nonmetallic cable connectors are used to

terminate Nonmetallic Sheathed Cable or Flexible

Cord to knockout in a dry location box or enclosure.

• Snap-In One Piece Construction

• Wide Variety of Cable Configurations

Materials:• Plastic

Plastic Nonmetallic CableConnectors

NM / SE CABLECatalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-31857 Size A B C D E Qty/Qty Wt.

Boxed7118 07118-7 1/2" 1.34 2.42 .834 .883 .825 50/250 8.1

Trade Size One Cable Two Cables

3/8" (1) 14/2 -10/2 (2) 14/2- 10/2

(1) 14/3- 10-3 (1) 14/2 & 12/2

(1) 14/2 & 10/2

(1) 12/2 & 10/2

NM

/SE

CA

BLE

Teddico/BWF Pittsburgh, Pa. 15205

• Accommodates one or two 4-2, 14-3 and 12-2 cables, one 12-3, 10-2 and 10-3 cable, and one or two .300 inch or .600 inch diameter cords• Push-in design with a captive lock wedge that secures cable with a single squeeze from standard electrician’s pliers• Excellent insulation, superior strain relief• Sized to fit 1/2 inch (12.70mm) knockout size

Catalog UPC No Trade Ctn/Case Case

Number 0-87115 Size Qty/Qty Wt.

3-9

E66712

Page 35: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

i- L

IQU

ID T

IG

HT

Straight Liquid-Tight Connectors

Use: Straight liquid-tight connectors are used to termi-nate and seal Liquid-Tight Flexible Metal and Liquid-Tight Flexible Nonmetallic Type B Conduits to either an oil-tight, liquid-tight or rain-tight box or enclosure. Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut.

• Furnished with Sealing Ring

• Suitable for Grounding (up to 1W)

Materials • Zinc Die-Cast Certification

E155411 LR57925•

Standards UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 351

Straight Liquid-Tight Connectors (Malleable Iron)

Use: Straight liquid-tight connectors are used to termi-nate and seal Liquid-Tight Flexible Metal and Liquid-Tight Flexible Nonmetallic Type B Conduits to either an oil-tight, liquid-tight or rain-tight box or enclosure. Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut. • Tapered threaded male hub - NPT • Compact, slim diameter • Steel locknut • Liquidtight/Raintight/Oikight • Suitable for wet locations • Long ferrule prevents pullout & tight bend conduit pop out

Materials • Malleable Iron

Certification

cgpos E 875 E186219

Standards UL 514B NEMA FB-1

LIQUID TIGHT Catalog Number

UPC No Trade

0-87115 Size Nominal Dimensions

A B C Ctn/Case

Qty/Qty

Case Wt.

Boxed 8248 08248-0 3/8" 2.80 2.95 0.66 25/100 15.0 8310 08310-4 1/2" 1.50 1.22 0.50 25/100 13.8 8311 08311-1 3/4" 1.60 1.48 0.50 10/100 20.0 8312 08312-8 1" 2.00 1.75 0.68 5/25 8.5 8313 08313-5 11/4" 2.24 2.23 0.68 5/25 14.1 8314 08314-2 11/2" 2.50 2.48 0.66 2/10 6.4 8315 08315-9 2" 2.80 2.95 0.66 2/10 8.6 8316 08316-6 2 1/2" 2.00 1.75 0.68 1 2.1 8317 08317-3 3" 2.24 2.23 0.68 1 2.8 8318 08318-0 31/2" 2.50 2.48 0.66 1 3.2 8319 08319-7

Boxed w/ insu lated throat

4" 2.80 2.95 0.66 1 3.7

8249 08249-7 3/8" 2.80 2.95 0.66 25/100 15.6 8320 08320-3 1/2" 1.50 1.22 0.50 25/100 14.4 8321 08321-0 3/4" 1.60 1.48 0.50 10/100 20.8 8322 08322-7 1" 2.00 1.75 0.68 5/25 8.8 8323 08323-4 1 1/4" 2.24 2.23 0.68 5/25 14.5 8324 08324-1 1 1/2" 2.50 2.48 0.66 2/10 6.6 8325 08325-8 2" 2.80 2.95 0.66 2/10 8.9 8326 08326-5 2 1/2" 2.00 1.75 0.68 1 2.1 8327 08327-2 3" 2.24 2.23 0.68 1 2.8 8328 08328-9 3 1/2" 2.50 2.48 0.66 1 3.2 8329 08329-6 4" 2.80 2.95 0.66 1 3.7

LIQUID TIGHT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions A B C

Ctn/Case Case Qty/Qty Wt.

Boxed 9376 09376-9 3/8" 1 1/8" 1/2" 1 1/8" 25/100 15.4 9370 09370-7 1/2" 1 1/4" 1/2" 1 1/4" 25/100 17.6 9371 09371-4 3/4" 1 1/4" 1/2" 1 9/16" 10/100 28.7 9372 09372-1 1" 1 7/16" 5/8" 1 13/16" 5/50 19.9 9373 09373-8 1 1/4" 1 1/2" 11/16" 2 1/4" 5/50 27.6 9374 09374-5 1 1/2" 1 5/8" 3/4" 2 7/16" 2/20 14.1 9375 09375-0 2" 1 3/4" 3/4" 3" 2/20 19.8 9427 19427-8 2 1/2" 2 3/16" 1" 4" 1 3.6 9428 19428-5 3" 2 1/2" 1 1/8" 4 3/16" 1 4.6 9429 09429-0 3 1/2" 2 5/8" 1 3/16" 5 1/4" 1 6.7 9430 09430-8 4"

Boxed w/ insu lated throat

2 3/4" 1 1/4" 5 3/4" 1 7.9

9386 09386-8 3/8" 1 1/8" 9/16" 1 1/8" 25/100 15.4 9380 09380-6 1/2" 1 1/4" 9/16" 1 1/4" 25/100 17.6 9381 09381-3 3/4" 1 1/4" 9/16" 1 9/16" 10/100 28.7 9382 09382-0 1" 1 7/16" 11/16" 1 13/16" 5/50 19.9 9383 09383-7 1 1/4" 1 1/2" 3/4" 2 1/4" 5/50 27.6 9384 09384-4 1 1/2" 1 5/8" 1 3/16" 2 7/16" 2/20 14.1 9385 09385-1 2" 1 3/4" 1 3/16" 3" 2/20 19.8 9431 09431-5 2 1/2" 2 3/16" 1 1/16" 4" 1 3.6 9432 09432-0 3" 2 1/2" 1 3/16" 4 3/16" 1 4.6 9433 09433-9 3 1/2" 2 5/8" 1 1/4" 5 1/4" 1 6.7 9434 09434-6 4" 2 3/4" 1 5/16" 5 3/4" 1 7.9

* UL Listed liquidtight flexible metal conduit fittings are suitable for use in the following hazardous locations under NEC 501-4(b), 502-4(a)(2); Class I , Div. 2; Class I I , Div. 1 and 2; and Class I I I , Div. 1 and 2.

TE13131C13 BWE Teddico/BWF Pittsburgh, Pa. 15205

ELECTRICAL PRODUCTS

Use:Straight liquid-tight connectors are used to termi-

nate and seal Liquid-Tight Flexible Metal and

Liquid-Tight Flexible Nonmetallic Type B Conduits

to either an oil-tight, liquid-tight or rain-tight box or

enclosure. Connectors can be used with tapered

thread female entry or unthreaded knock-out using

the provided sealing washer and locknut.

• Furnished with Sealing Ring

• Suitable for Grounding (up to 1¼")

Materials• Zinc Die-Cast

Certification E155411 LR57925

Standards UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 351

Straight Liquid-Tight Connectors LIQUID TIGHT

Boxed

A

C

B

Boxed w/ insulated throat

Teddico/BWF Pittsburgh, Pa. 15205

LIQ

UID

TIG

HT

Use:Straight liquid-tight connectors are used to termi-

nate and seal Liquid-Tight Flexible Metal and

Liquid-Tight Flexible Nonmetallic Type B Conduits

to either an oil-tight, liquid-tight or rain-tight box or

enclosure. Connectors can be used with tapered

thread female entry or unthreaded knock-out using

the provided sealing washer and locknut.

Materials• Malleable Iron

Certification

Standards UL 514B

NEMA FB-1

Straight Liquid-Tight Connectors LIQUID TIGHT

Boxed

Boxed w/ insulated throat

(M alleab le Iron)

• Tapered threaded male hub - NPT

• Compact, slim diameter

• Steel locknut

• Liquidtight/Raintight/Oiltight

• Suitable for wet locations

• Long ferrule prevents pullout

& tight bend conduit pop out

* UL Listed liquidtight flexible metal

conduit fittings are suitable for use in

the following hazardous locations

under NEC 501-4(b), 502-4(a)(2);

Class I, Div. 2; Class II, Div. 1 and 2;

and Class III, Div. 1 and 2.

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

9376 09376-9 3/8" 1 1/8" 1/2" 1 1/8" 25/100 15.4

9370 09370-7 1/2" 1 1/4" 1/2" 1 1/4" 25/100 17.6

9371 09371-4 3/4" 1 1/4" 1/2" 1 9/16" 10/100 28.7

9372 09372-1 1" 1 7/16" 5/8" 1 13/16" 5/50 19.9

9373 09373-8 1 1/4" 1 1/2" 11/16" 2 1/4" 5/50 27.6

9375 09375-0 2" 1 3/4" 3/4" 3" 2/20 19.89427 19427-8 2 1/2" 2 3/16" 1" 4" 1 3.6

9428 19428-5 3" 2 1/2" 1 1/8" 4 3/16" 1 4.6

9429 09429-0 3 1/2" 2 5/8" 1 3/16" 5 1/4" 1 6.7

9430 09430-8 4" 2 3/4" 1 1/4" 5 3/4" 1 7.9

9374 09374-5 1 1/2" 1 5/8" 3/4" 2 7/16" 2/20 14.1

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

8248 08248-0 3/8" 2.80 2.95 0.66 25/100 15.0

8310 08310-4 1/2" 1.50 1.22 0.50 25/100 13.8

8311 08311-1 3/4" 1.60 1.48 0.50 10/100 20.0

8312 08312-8 1" 2.00 1.75 0.68 5/25 8.5

8313 08313-5 1 1/4" 2.24 2.23 0.68 5/25 14.1

8314 08314-2 1 1/2" 2.50 2.48 0.66 2/10 6.4

8315 08315-9 2" 2.80 2.95 0.66 2/10 8.68316 08316-6 2 1/2" 2.00 1.75 0.68 1 2.1

8317 08317-3 3" 2.24 2.23 0.68 1 2.8

8318 08318-0 3 1/2" 2.50 2.48 0.66 1 3.2

8319 08319-7 4" 2.80 2.95 0.66 1 3.7

8249 08249-7 3/8" 2.80 2.95 0.66 25/100 15.6

8320 08320-3 1/2" 1.50 1.22 0.50 25/100 14.4

8321 08321-0 3/4" 1.60 1.48 0.50 10/100 20.8

8322 08322-7 1" 2.00 1.75 0.68 5/25 8.8

8323 08323-4 1 1/4" 2.24 2.23 0.68 5/25 14.5

8324 08324-1 1 1/2" 2.50 2.48 0.66 2/10 6.6

8325 08325-8 2" 2.80 2.95 0.66 2/10 8.98326 08326-5 2 1/2" 2.00 1.75 0.68 1 2.1

8327 08327-2 3" 2.24 2.23 0.68 1 2.8

8328 08328-9 3 1/2" 2.50 2.48 0.66 1 3.2

8329 08329-6 4" 2.80 2.95 0.66 1 3.7

9386 09386-8 3/8" 1 1/8" 9/16" 1 1/8" 25/100 15.4

9380 09380-6 1/2" 1 1/4" 9/16" 1 1/4" 25/100 17.6

9381 09381-3 3/4" 1 1/4" 9/16" 1 9/16" 10/100 28.7

9382 09382-0 1" 1 7/16" 11/16" 1 13/16" 5/50 19.9

9383 09383-7 1 1/4" 1 1/2" 3/4" 2 1/4" 5/50 27.6

9384 09384-4 1 1/2" 1 5/8" 1 3/16" 2 7/16" 2/20 14.1

9385 09385-1 2" 1 3/4" 1 3/16" 3" 2/20 19.89431 09431-5 2 1/2" 2 3/16" 1 1/16" 4" 1 3.6

9432 09432-0 3" 2 1/2" 1 3/16" 4 3/16" 1 4.6

9433 09433-9 3 1/2" 2 5/8" 1 1/4" 5 1/4" 1 6.7

9434 09434-6 4" 2 3/4" 1 5/16" 5 3/4" 1 7.9

4-1

E186219

Page 36: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

90° Liquid-Tight Connectors

A

Use: 90° liquid-tight connectors are used to terminate and seal Liquid-Tight Flexible Metal and Liquid-Tight Flexible Nonmetallic Type B Conduits at 90° angles to either an oil-tight, liquid-tight or rain-tight box or enclosure. Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and lock-nut.

• UL Listed Locknut

• Furnished with Sealing Ring

• Suitable for Grounding (up to 1 1/4")

Materials • Zinc Die-Cast Certification

E155411 LR57925

Standards UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 351

90° Liquid-Tight Connectors (Malleable Iron)

Use: 90° liquid-tight connectors are used to terminate and seal Liquid-Tight Flexible Metal and Liquid-Tight Flexible Nonmetallic Type B Conduits at 90° angles to either an oil-tight, liquid-tight or rain-tight box or enclosure. Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and lock-nut.

• UL Listed Locknut

• Furnished with Sealing Ring

• Suitable for Grounding (up to 1Y4")

Materials • Malleable Iron

Certification

CP11$ ▪ 675

Standards UL 514B NEMA FB-1

LIQUID TIGHT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions Pcs/ A B C Unit

Ctn/Case Case

Qty/Qty Wt.

Boxed 8246 08246-6 3/8" 1.50 1.21 0.50 10/50 11.9 8280 08280-0 1/2" 1.52 1.21 0.50 10/50 11.5 8281 08281-7 3/4" 1.60 1.37 0.53 10/50 27.5 8282 08282-4 1" 2.00 1.73 0.69 5/25 11.5 8283 08283-1 1" 1/4" 2.24 2.13 0.67 5/25 19.8 8284 08284-8 1" 1/2" 2.50 2.44 0.67 2/10 10.3 8285 08285-5 2" 2.80 2.94 0.67 2/10 13.0 8286 08286-2 21/2" 2.00 1.75 0.68 1 3.6 8287 08287-9 3" 2.24 2.23 0.68 1 5.6 8288 08288-6 3 1/2" 2.50 2.48 0.66 1 2.7 8289 08289-3 4" Boxed w/ insu lated throat

2.80 2.95 0.66 1 3.3

8247 08247-3 3/8" 2.80 2.95 0.66 10/50 11.9 8290 08290-9 1/2" 1.50 1.22 0.50 10/50 11.5 8291 08291-6 3/4" 1.60 1.48 0.50 10/50 27.5 8292 08292-3 1" 2.00 1.75 0.68 5/25 11.5 8293 08293-0 1 1/4" 2.24 2.23 0.68 5/25 19.8 8294 08294-7 1 1/2" 2.50 2.48 0.66 2/10 10.3 8295 08295-4 2" 2.80 2.95 0.66 2/10 13.0 8296 08296-1 2 1/2" 2.00 1.75 0.68 1 3.6 8297 08297-8 3" 2.24 2.23 0.68 1 5.6 8298 08298-5 3 1/2" 2.50 2.48 0.66 1 2.7 8299 08299-2 4" 2.80 2.95 0.66 1 3.3

LIQUID TIGHT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions A C

Ctn/Case

Qty/Qty Case

Wt.

Boxed 9416 09416-2 3/8" 1 5/16" 1/2" 1 1/8" 10/100 25.4 9410 09410-0 1/2" 1 7/16" 1/2" 1 1/4" 10/100 28.9 9411 09411-7 3/4" 1 5/8" 1/2" 1 9/16" 10/100 44.1 9412 09412-4 1" 2 5/16" 5/8" 1 13/16" 5/50 37.3 9413 09413-1 1 1/4" 2 3/8" 11/16" 2 1/4" 2/20 19.2 9414 09414-0 1 1/2" 3 11/16" 3/4" 2 7/16" 2/20 24.3 9415 09415-5 2" 3 3/16" 3/4" 3" 1/10 17.6 9478 09478-0 2 1/2" 8 5/16" 1" 4" 1 8.4 9479 09479-7 3" 9 13/16" 1 1/8" 4 3/16" 1 12.4 9480 09480-3 3 1/2" 11 3/16 1 3/16" 5 1/4" 1 19.0 9481 09481-0 4" 13" 1 1/4" 5 3/4" 1 23.8

Boxed w/ insu lated throat 9426 09426-1 3/8" 1 5/16" 9/16" 1 1/8" 10/100 25.7 9420 09420-9 1/2" 1 7/16" 9/16" 1 1/4" 10/100 29.2 9421 09421-6 3/4" 1 5/8" 9/16" 1 9/16" 10/100 44.6 9422 09422-3 1" 2 5/16" 5/8" 1 13/16" 5/50 37.7 9423 09423-0 1 1/4" 2 3/8" 3/4" 2 1/4" 2/20 19.4 9424 09424-7 1 1/2" 2 11/16" 1 3/16" 2 7/16" 2/20 24.5 9425 09425-4 2" 3 3/16" 1 3/16" 3" 1/10 17.8 9482 09482-7 2 1/2" 8 5/16" 1 1/16" 4" 1 8.5 9483 09483-4 3" 9 13/16" 1 3/16" 4 3/16" 1 12.5 9484 09484-1 3 1/2" 11 3/16" 1 1/4" 5 1/4" 1 19.1 9485 09485-8 4" 13" 1 5/16" 5 3/4" 1 24.0

E186219

Teddico/BWF Pittsburgh, Pa. 15205 TECICIICCD BWF ELECTRICAL PRODUCTS

Use:90° liquid-tight connectors are used to terminate

and seal Liquid-Tight Flexible Metal and Liquid-

Tight Flexible Nonmetallic Type B Conduits at 90°

angles to either an oil-tight, liquid-tight or rain-tight

box or enclosure. Connectors can be used with

tapered thread female entry or unthreaded knock-

out using the provided sealing washer and lock-

nut.

• UL Listed Locknut

• Furnished with Sealing Ring

• Suitable for Grounding (up to 1¼")

Materials • Malleable Iron

Certification

Standards UL 514BNEMA FB-1

90° Liquid-Tight Connectors LIQUID TIGHT

Boxed

Boxed w/ insulated throat

Teddico/BWF Pittsburgh, Pa. 15205

LIQU

ID T

IGH

T

Use:90° liquid-tight connectors are used to terminate

and seal Liquid-Tight Flexible Metal and Liquid-

Tight Flexible Nonmetallic Type B Conduits at 90°

angles to either an oil-tight, liquid-tight or rain-tight

box or enclosure. Connectors can be used with

tapered thread female entry or unthreaded knock-

out using the provided sealing washer and lock-

nut.

• UL Listed Locknut

• Furnished with Sealing Ring

• Suitable for Grounding (up to 1¼")

Materials • Zinc Die-Cast

CertificationE155411 LR57925

Standards UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 351

90° Liquid-Tight Connectors LIQUID TIGHTCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8246 08246-6 3/8" 1.50 1.21 0.50 - 10/50 11.9

8280 08280-0 1/2" 1.52 1.21 0.50 - 10/50 11.5

8281 08281-7 3/4" 1.60 1.37 0.53 - 10/50 27.5

8282 08282-4 1" 2.00 1.73 0.69 - 5/25 11.5

8283 08283-1 1" 1/4" 2.24 2.13 0.67 - 5/25 19.8

8284 08284-8 1" 1/2" 2.50 2.44 0.67 - 2/10 10.3

8285 08285-5 2" 2.80 2.94 0.67 - 2/10 13.0

A

B

C

8290 08290-9 1/2" 1.50 1.22 0.50 - 10/50 11.5

8291 08291-6 3/4" 1.60 1.48 0.50 - 10/50 27.5

8292 08292-3 1" 2.00 1.75 0.68 - 5/25 11.5

8293 08293-0 1 1/4" 2.24 2.23 0.68 - 5/25 19.8

8294 08294-7 1 1/2" 2.50 2.48 0.66 - 2/10 10.3

8295 08295-4 2" 2.80 2.95 0.66 - 2/10 13.0

Boxed w/ insulated throat8247 08247-3 3/8" 2.80 2.95 0.66 - 10/50 11.9

8286 08286-2 2 1/2" 2.00 1.75 0.68 - 1 3.6

8287 08287-9 3" 2.24 2.23 0.68 - 1 5.6

8288 08288-6 3 1/2" 2.50 2.48 0.66 - 1 2.7

8289 08289-3 4" 2.80 2.95 0.66 - 1 3.3

8296 08296-1 2 1/2" 2.00 1.75 0.68 - 1 3.6

8297 08297-8 3" 2.24 2.23 0.68 - 1 5.6

8298 08298-5 3 1/2" 2.50 2.48 0.66 - 1 2.7

8299 08299-2 4" 2.80 2.95 0.66 - 1 3.3

(M alleab le Iron)Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

9416 09416-2 3/8" 1 5/16" 1/2" 1 1/8" 10/100 25.4

9410 09410-0 1/2" 1 7/16" 1/2" 1 1/4" 10/100 28.9

9411 09411-7 3/4" 1 5/8" 1/2" 1 9/16" 10/100 44.1

9412 09412-4 1" 2 5/16" 5/8" 1 13/16" 5/50 37.3

9413 09413-1 1 1/4" 2 3/8" 11/16" 2 1/4" 2/20 19.2

9414 09414-0 1 1/2" 3 11/16" 3/4" 2 7/16" 2/20 24.3

9415 09415-5 2" 3 3/16" 3/4" 3" 1/10 17.69478 09478-0 2 1/2" 8 5/16" 1" 4" 1 8.4

9479 09479-7 3" 9 13/16" 1 1/8" 4 3/16" 1 12.4

9480 09480-3 3 1/2" 11 3/16 1 3/16" 5 1/4" 1 19.0

9481 09481-0 4" 13" 1 1/4" 5 3/4" 1 23.8

9426 09426-1 3/8" 1 5/16" 9/16" 1 1/8" 10/100 25.7

9420 09420-9 1/2" 1 7/16" 9/16" 1 1/4" 10/100 29.2

9421 09421-6 3/4" 1 5/8" 9/16" 1 9/16" 10/100 44.6

9422 09422-3 1" 2 5/16" 5/8" 1 13/16" 5/50 37.7

9423 09423-0 1 1/4" 2 3/8" 3/4" 2 1/4" 2/20 19.4

9424 09424-7 1 1/2" 2 11/16" 1 3/16" 2 7/16" 2/20 24.5

9425 09425-4 2" 3 3/16" 1 3/16" 3" 1/10 17.8

9482 09482-7 2 1/2" 8 5/16" 1 1/16" 4" 1 8.5

9483 09483-4 3" 9 13/16" 1 3/16" 4 3/16" 1 12.5

9484 09484-1 3 1/2" 11 3/16" 1 1/4" 5 1/4" 1 19.1

9485 09485-8 4" 13" 1 5/16" 5 3/4" 1 24.0

4-2

E186219

Page 37: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

E186219

TECII CI I CCV,BvilF , I„ Hir.n.L I-F-1E-111,17 . 1

Teddico/BWF Pittsburgh, Pa. 15205

t, L

IQU

ID T

IGH

T

45° Liquid-Tight Connectors (Malleable Iron)

Use: 90° liquid-tight connectors are used to terminate and seal Liquid-Tight Flexible Metal and Liquid-Tight Flexible Nonmetallic Type B Conduits at 90°

box or enclosure. Connectors can be used with tapered thread female entry or unthreaded knock- out using the provided sealing washer and lock- nut.

• Furnished with Sealing Ring

• Suitable for Grounding (up to 1 1/4")

Materials

• Malleable Iron Certification

1193 S?75

Straight Liquid-Tight Connectors

Use: Straight liquid-tight connectors are used to terminate and seal Liquid -Tight F exible Nonmetallic Type B Conduit to either an oil-tight, liquid-tight or rain-tight box or enclosure. Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing wash-er and locknut. • Resists Salt Water, Weak Acids, Gasoline, Alcohol, Oil, Grease and Common Solvents • No Disassembly Required • Reusable

Materials • Nylon

E186219

90° Liquid-Tight Connectors

Use: 90° liquid-tight connectors are used to terminate and seal Liquid-Tight Flexible Nonmetallic Type B Conduits at 90° angles to either an oil-tight, liquid-tight or rain-tight box or enclosure. Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut. • Resists Salt Water, Weak Acids, Gasoline, Alcohol, Oil, Grease and Common Solvents • No Disassembly Required • Reusable

Materials • Nylon

LIQUID TIGHT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions A B C

Ctn/Case

Qty/Qty

Case Wt.

Boxed 9396 09396-7 3/8" 1 15/16" 1/2" 1 1/8" 10/100 25.4 9390 09390-5 1/2" 2" 1/2" 11/4" 10/100 28.9 9391 09391-2 3/4" 2 3/16" 1/2" 1 9/16" 10/100 44.1 9392 09392-9 1" 21/2" 5/8" 113/16" 5/50 37.3 9393 09393-6 11/4" 213/16" 11/16" 21/4" 2/20 19.2 9394 09394-3 1 1/2" 3" 3/4" 2 7/16" 2/20 24.3 9395 09395-0 2" 311/16" 3/4" 3" 1/10 17.6

9406 09406-3 3/8" 1 15/16" 9/16" 1 1/8" 10/100 25.7 9400 09400-1 1/2" 2" 9/16" 1 1/4" 10/100 29.2 9401 09401-8 3/4" 2 3/16" 9/16" 1 9/16" 10/100 44.6 9402 09402-5 1" 21/2" 5/8" 113/16" 5/50 37.7 9403 09403-2 11/4" 213/16" 3/4" 21/4" 2/20 19.6 9404 09404-9 1 1/2" 3" 1 3/16" 2 7/16" 2/20 24.8 9405 09405-6 2" 311/16" 13/16" 3" 1/10 17.9

LIQUID TIGHT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions A B

Ctn/Case

Qty/Qty

Case Wt.

Boxed

7106 07106-4 3/8" 1.44 2.31 20 2.0 7100 07100-2 1/2" 1.63 2.50 25/100 10.0 7101 07101-9 3/4" 1.94 2.81 20 2.5 7102 07102-6 1" 2.25 3.44 10 2.1 7103 07103-3 1 1/4" 2.69 4.25 5/50 12.0 7104 07104-0 1 1/2" 3.13 4.69 5/20 14.0 7105 07105-0 2" 3.63 5.31 2/20 9.0

LIQUID TIGHT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions A B

Ctn/Case

Qty/Qty

Case

Wt.

Boxed 7116 07116-3 3/8" 2.00 1.40 20 2.2 7110 07110-1 1/2" 2.00 1.40 20 2.2 7111 07111-8 3/4" 2.15 1.68 20 2.8 7112 07112-5 1" 2.25 2.00 10 2.5 7113 07113-2 1 1/4" 1.26 1.20 2/20 8.0 7114 07114-9 1 1/2" 1.43 1.46 2/20 10.0 7115 07115-6 2" 1.85 1.78 1/10 9.0

angles to either an oil-tight, liquid-tight or rain-tight Boxed w/ insu lated throat

Use:Straight liquid-tight connectors are used to terminate andseal Liquid -Tight Flexible Nonmetallic Type B Conduit toeither an oil-tight, liquid-tight or rain-tight box or enclosure.Connectors can be used with tapered thread female entryor unthreaded knock-out using the provided sealing wash-er and locknut.• Resists Salt Water, Weak Acids, Gasoline, Alcohol,Oil, Grease and Common Solvents• No Disassembly Required• Reusable

Materials • Nylon

Straight Liquid-Tight Connectors LIQUID TIGHT

Boxed

A

B

Use:90° liquid-tight connectors are used to terminate andseal Liquid-Tight Flexible Nonmetallic Type B Conduitsat 90° angles to either an oil-tight, liquid-tight or rain-tightbox or enclosure. Connectors can be used with taperedthread female entry or unthreaded knock-out using theprovided sealing washer and locknut.• Resists Salt Water, Weak Acids, Gasoline,Alcohol, Oil, Grease and Common Solvents• No Disassembly Required• Reusable

Materials • Nylon

90° Liquid-Tight ConnectorsLIQUID TIGHT

Boxed

A

B

C

LIQ

UID

TIG

HT

Teddico/BWF Pittsburgh, Pa. 15205

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B Qty/Qty Wt.

7106 07106-4 3/8" 1.44 2.31 20 2.0

7100 07100-2 1/2" 1.63 2.50 25/100 10.0

7101 07101-9 3/4" 1.94 2.81 20 2.5

7102 07102-6 1" 2.25 3.44 10 2.1

7103 07103-3 1 1/4" 2.69 4.25 5/50 12.0

7104 07104-0 1 1/2" 3.13 4.69 5/20 14.0

7105 07105-0 2" 3.63 5.31 2/20 9.0

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Qty/Qty Wt.Number 0-87115 Size A B

20 2.2

20 2.2

20 2.8

10 2.5

2/20 8.0

2/20 10.0

1/10 9.0

7116 07116-3 3/8" 2.00 1.40

7110 07110-1 1/2" 2.00 1.40

7111 07111-8 3/4" 2.15 1.68

7112 07112-5 1" 2.25 2.00

7113 07113-2 1 1/4" 1.26 1.20

7114 07114-9 1 1/2" 1.43 1.46

7115 07115-6 2" 1.85 1.78

4-3

Use:90° liquid-tight connectors are used to terminate

and seal Liquid-Tight Flexible Metal and Liquid-

Tight Flexible Nonmetallic Type B Conduits at 90°

angles to either an oil-tight, liquid-tight or rain-tight

box or enclosure. Connectors can be used with

tapered thread female entry or unthreaded knock-

out using the provided sealing washer and lock-

nut.

• Furnished with Sealing Ring

• Suitable for Grounding (up to 1¼")

Materials • Malleable Iron

Certification

45° Liquid-Tight Connectors LIQUID TIGHT

Boxed

Boxed w/ insulated throat

(M alleab le Iron)Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

9396 09396-7 3/8" 1 15/16" 1/2" 1 1/8" 10/100 25.4

9390 09390-5 1/2" 2" 1/2" 1 1/4" 10/100 28.9

9391 09391-2 3/4" 2 3/16" 1/2" 1 9/16" 10/100 44.1

9392 09392-9 1" 2 1/2" 5/8" 1 13/16" 5/50 37.3

9393 09393-6 1 1/4" 2 13/16" 11/16" 2 1/4" 2/20 19.2

9394 09394-3 1 1/2" 3" 3/4" 2 7/16" 2/20 24.3

9395 09395-0 2" 3 11/16" 3/4" 3" 1/10 17.6

9406 09406-3 3/8" 1 15/16" 9/16" 1 1/8" 10/100 25.7

9400 09400-1 1/2" 2" 9/16" 1 1/4" 10/100 29.2

9401 09401-8 3/4" 2 3/16" 9/16" 1 9/16" 10/100 44.6

9402 09402-5 1" 2 1/2" 5/8" 1 13/16" 5/50 37.7

9403 09403-2 1 1/4" 2 13/16" 3/4" 2 1/4" 2/20 19.6

9404 09404-9 1 1/2" 3" 1 3/16" 2 7/16" 2/20 24.8

9405 09405-6 2" 3 11/16" 1 3/16" 3" 1/10 17.9

E186219

E186219

Page 38: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Compression Connectors

RIGID CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Ctn/Case Qty/Qty

Case Wt.

Boxed 9146* 09146-8 2-1/2" 8 13.0 9147* 09147-5 3" 5 12.0 9148* 09148-2 3-1/2" 5 15.0 9149* 09149-9 4" 5 17.0

Use: * EMT & RIGID

Compression type connectors are used to secure and terminate threadless Rigid or IMC Conduits to a steel outlet box or metal enclosure. • Concrete-Tight

Materials: • Steel ® E210498 e LR57925

E155411 E184480

Compression Couplings

RIGID CONDUIT Catalog

UPC No

Trade

Ctn/Case

Case Number

0-87115

Size

Qty/Qty

Wt.

9136* 09136-9 2-1/2" 8 13.0 9137* 09137-6 3" 5 13.0 9138* 09138-3 3-1/2" 5 13.0 9139* 09139-0 4" 5 18.0

Boxed

Use: * EMT & RIGID

Compression type couplings are used to join two lengths of threadless Rigid or IMC Conduit. • Concrete-Tight

Materials: • Steel 11) E210498 LR57925

E155411 E184480

Three Piece Couplings

RIGID CONDUIT

Use: Used to connect two lenghts of threaded rigid conduit or IMC,when neither conduit can be turned. Cast of high strength malleable iron and zinc plated.

• Concrete-Tight

Catalog Number

UPC No 0-31857

Trade Size

Nominal Dimensions Pcs/ A B C Unit

Ctn/Case Case Qty/Qty Wt.

Boxed 9520 09520-6 1/2" 1.64 1.13 0.85 10/100 20.4 9521 09521-3 3/4" 1.80 1.37 1.07 5/50 12.9 9522 09522-0 1" 1.88 1.69 1.29 5/50 25.2 9523 09523-7 1 1/4" 2.09 2.07 1.61 5/25 22.3 9524 09524-4 1 1/2" 2.40 2.28 1.85 5/25 30.7 9525 09525-1 2" 2.33 2.78 2.33 20 36.8 9526 09526-8 2 1/2" 2.09 2.07 1.61 10 31.0 9527 09527-5 3" 2.40 2.28 1.85 5 16.0 9528 09528-2 3 1/2" 2.33 2.78 2.33 5 29.8 9529 09529-9 4" 2.33 2.78 2.33 2 15.1

Materials: • Malleable Iron

® E155411 LR57925

E207875 @Os

TEDDICD BwF Teddico/BWF Pittsburgh, Pa. 15205

Use:Compression type connectors are used to secure

and terminate threadless Rigid or IMC Conduits to

a steel outlet box or metal enclosure.

• Concrete-Tight

Materials:• Steel

Compression Connectors RIGID CONDUIT

Boxed

Use:Compression type couplings are used to join two

lengths of threadless Rigid or IMC Conduit.

• Concrete-Tight

Materials:• Steel

Compression Couplings RIGID CONDUIT

Boxed

RIG

ID C

ON

DU

IT

Teddico/BWF Pittsburgh, Pa. 15205

Use:Used to connect two lenghts of threaded rigid

conduit or IMC,when neither conduit can be turned.

• Concrete-Tight

Materials:• Malleable Iron

Three Piece Couplings RIGID CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-31857 Size A B C Unit Qty/Qty Wt.

Boxed9520 09520-6 1/2" 1.64 1.13 0.85 - 10/100 20.4

9521 09521-3 3/4" 1.80 1.37 1.07 - 5/50 12.9

9522 09522-0 1" 1.88 1.69 1.29 - 5/50 25.2

9523 09523-7 1 1/4" 2.09 2.07 1.61 - 5/25 22.3

9524 09524-4 1 1/2" 2.40 2.28 1.85 - 5/25 30.7

9525 09525-1 2" 2.33 2.78 2.33 - 20 36.8

Cast of high strength malleable iron and zinc plated.

9526 09526-8 2 1/2" 2.09 2.07 1.61 - 10 31.0

9527 09527-5 3" 2.40 2.28 1.85 - 5 16.0

9528 09528-2 3 1/2" 2.33 2.78 2.33 - 5 29.8

9529 09529-9 4" 2.33 2.78 2.33 - 2 15.1

* EMT & RIGID

* EMT & RIGID

5-1

E210498 LR57925

E155411

E184480

E210498 LR57925

E155411

E184480

Catalog UPC No Trade

Number 0-87115 Size

9146* 09146-8 2-1/2"

9147* 09147-5 3"9148* 09148-2 3-1/2"

9149* 09149-9 4"

Ctn/Case Case

Qty/Qty Wt.

8 13.0

5 12.05 15.05 17.0

Catalog UPC No Trade Ctn/Case Case

Number 0-87115 Size Qty/Qty Wt.

9136* 09136-9 2-1/2" 8 13.0

9137* 09137-6 3" 5 13.09138* 09138-3 3-1/2" 5 13.0

9139* 09139-0 4" 5 18.0

E155411 LR57925

Page 39: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

N, R

IG

ID C

ON

DU

IT

Compression Rigid Connectors For threadless Rigid Conduit and IMC

Malleable Iron A7"

Use: Compression type connectors are used to secure and terminate threadless Rigid or IMC Conduits to a steel outlet box or metal enclosure.

• Concrete-Tight

Materials: • Malleable Iron

Certification

US E20 7875

Compression Rigid Coupling For threadless Rigid Conduit and IMC

Malleable Iron

Use: Compression type couplings are used to join two lengths of threadless Rigid or IMC Conduit.

• Concrete-Tight

Materials: • Steel

Certification

'10 us E 20 7875

RIGID CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions A B C

Ctn/Case Case Qty/Qty Wt.

Boxed 9160 09160-4 1/2" 11/2" 1/2" 11/2" 25/250 50.8 9161 09161-1 3/4" 1 1/2" 1/2" 1 5/8" 25/250 55.8 9162 09162-8 1" 111/16" 9/16" 2" 25/100 33.7 9163 09163-5 1 1/4" 2" 11/16" 2 3/8" 5/50 26.0 9164 09164-2 1 1/2" 2 1/16" 11/16" 2 5/8" 5/50 32.7 9165 09165-0 2" 2 1/4" 7/8" 3 5/16" 20 21.4 9166 09166-6 2 1/2" 2 15/16" 1 1/4" 3 3/4" 5 12.1 9167 09167-3 3" 3 1/8" 1 3/8" 4 1/4" 3 8.9 9168 09168-0 3 1/2" 3 1/8" 1 3/8" 4 3/4" 2 7.7 9169 09169-7 4" 3 3/8" 1 1/2" 5 5/16" 2 9.4

Boxed KV insulated throat 9170 09170-3 1/2" 19/16" 9/16" 11/2" 25/250 51.3 9171 09171-0 3/4" 1 9/16" 9/16" 1 5/8" 25/250 56.5 9172 09172-7 1" 13/4" 5/8" 2" 25/100 34.1 9173 09173-4 1 1/4" 2" 11/16" 2 3/8" 5/50 26.3 9174 09174-1 1 1/2" 2 1/8" 3/4" 2 5/8" 5/50 33.0 9175 09175-8 2" 2 5/16" 13/16" 3 5/16" 20 22.7 9176 09176-5 2 1/2" 3" 1 5/16" 3 3/4" 5 12.3 9177 09177-2 3" 3 1/8" 1 7/16" 4 1/4" 3 9.0 9178 09178-0 3 1/2" 3 3/16" 1 1/2" 4 3/4" 2 7.8 9179 09179-6 4" 3 7/16" 1 9/16" 5 5/16" 2 9.4

RIGID CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions A B C

Ctn/Case Case Qty/Qty Wt.

Boxed 9180 09180-2 1/2" 1 13/16" 1/2" 1 1/2" 10/100 30.0 9181 09181-0 3/4" 17/8" 1/2" 15/8" 10/100 32.0 9182 09182-6 1" 2 3/16" 9/16" 2" 5/50 21.9 9183 09183-3 1 1/4" 2 5/8" 3/4" 2 3/8" 5/50 38.8 9184 09184-0 1 1/2" 2 11/16" 11/16" 2 5/8" 12 11.2 9185 09185-7 2" 3 1/16" 15/16" 3 5/16" 5 8.0 9186 09186-4 2 1/2" 4 1/2" 2" 3 3/4" 5 13.8 9187 09187-1 3" 4 15/16" 2 1/4" 4 1/4" 3 11.8 9188 09188-8 3 1/2" 5" 2 1/4" 4 3/4" 2 10.9 9189 09189-5 4" 5 5/16" 2 7/16" 5 5/16" 2 12.5

TEDDICD ,,,,1 HinftL HHE-111L11-. I A -

Teddico/BWF Pittsburgh, Pa. 15205

For threadless Rigid Conduit and IMC

Use:Compression type connectors are used to secure

and terminate threadless Rigid or IMC Conduits to

a steel outlet box or metal enclosure.

• Concrete-Tight

Materials:• Malleable Iron

Compression Rigid Connectors RIGID CONDUIT

Boxed

Use:Compression type couplings are used to join two

lengths of threadless Rigid or IMC Conduit.

• Concrete-Tight

Materials:• Steel

Compression Rigid Coupling RIGID CONDUIT

RIG

ID C

ON

DU

IT

Boxed w/ insulated throat

Boxed

Teddico/BWF Pittsburgh, Pa. 15205

Malleable Iron

For threadless Rigid Conduit and IMCMalleable Iron

Certification

Certification

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

9160 09160-4 1/2" 1 1/2" 1/2" 1 1/2" 25/250 50.8

9161 09161-1 3/4" 1 1/2" 1/2" 1 5/8" 25/250 55.8

9162 09162-8 1" 1 11/16" 9/16" 2" 25/100 33.7

9163 09163-5 1 1/4" 2" 11/16" 2 3/8" 5/50 26.0

9164 09164-2 1 1/2" 2 1/16" 11/16" 2 5/8" 5/50 32.7

9165 09165-0 2" 2 1/4" 7/8" 3 5/16" 20 21.4

9166 09166-6 2 1/2" 2 15/16" 1 1/4" 3 3/4" 5 12.1

9167 09167-3 3" 3 1/8" 1 3/8" 4 1/4" 3 8.9

9168 09168-0 3 1/2" 3 1/8" 1 3/8" 4 3/4" 2 7.7

9169 09169-7 4" 3 3/8" 1 1/2" 5 5/16" 2 9.4

9170 09170-3 1/2" 1 9/16" 9/16" 1 1/2" 25/250 51.3

9171 09171-0 3/4" 1 9/16" 9/16" 1 5/8" 25/250 56.5

9172 09172-7 1" 1 3/4" 5/8" 2" 25/100 34.1

9173 09173-4 1 1/4" 2" 11/16" 2 3/8" 5/50 26.3

9174 09174-1 1 1/2" 2 1/8" 3/4" 2 5/8" 5/50 33.0

9175 09175-8 2" 2 5/16" 13/16" 3 5/16" 20 22.7

9176 09176-5 2 1/2" 3" 1 5/16" 3 3/4" 5 12.3

9177 09177-2 3" 3 1/8" 1 7/16" 4 1/4" 3 9.0

9178 09178-0 3 1/2" 3 3/16" 1 1/2" 4 3/4" 2 7.8

9179 09179-6 4" 3 7/16" 1 9/16" 5 5/16" 2 9.4

9180 09180-2 1/2" 1 13/16" 1/2" 1 1/2" 10/100 30.0

9181 09181-0 3/4" 1 7/8" 1/2" 1 5/8" 10/100 32.0

9182 09182-6 1" 2 3/16" 9/16" 2" 5/50 21.9

9183 09183-3 1 1/4" 2 5/8" 3/4" 2 3/8" 5/50 38.8

9184 09184-0 1 1/2" 2 11/16" 11/16" 2 5/8" 12 11.2

9185 09185-7 2" 3 1/16" 15/16" 3 5/16" 5 8.0

9186 09186-4 2 1/2" 4 1/2" 2" 3 3/4" 5 13.8

9187 09187-1 3" 4 15/16" 2 1/4" 4 1/4" 3 11.8

9188 09188-8 3 1/2" 5" 2 1/4" 4 3/4" 2 10.9

9189 09189-5 4" 5 5/16" 2 7/16" 5 5/16" 2 12.5

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

5-2

Page 40: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Use: Pull elbows are used to facilitate pulling conductors through a 90° bend in a run of Rigid or IMC conduit. The removable cover gives ample access so that wire pulling can be achieved without any obstructions.

• Removable Aluminum Cover

Materials • Zinc Die-Cast

• Neoprene Gasket

Certification

® E155411 41• LR57925

Standards UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 345 & 346

Rigid to Rigid Pull Elbows

Use: Pull elbows are used to facilitate pulling conductors through a 90° bend in a run of Rigid or IMC conduit. The removable cover gives ample access so that wire pulling can be achieved without any obstructions.

• Removable Aluminum Cover

RIGID CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions A B C

Ctn/Case Case

Qty/Qty Wt.

Boxed W/O Gasket 8345 08345-6 1/2" 1.31 1.02 0.96 10/100 18.8 8346

Boxed

08346-3 3/4"

With Gasket

1.37 1.28 1.26 5/50 13.3

8345-G 08359-3 1/2" 1.31 1.02 0.96 10/100 19.6 8346-G 08349-4 3/4" 1.37 1.28 1.26 5/50 13.7 8347-G 08347-0 1" 1.95 1.55 1.52 25 15.6 8348-G 08348-7 1 1/4" 2.32 1.92 1.88 20 18.8

Materials • Zinc Die-Cast

• Neoprene Gasket

Certification

® E155411 LR57925

Standards UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 345 & 346

Rigid to Box Pull Elbows RIGID CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions A B C

Ctn/Case Case

Qty/Qty Wt.

Boxed W/O Gasket 8335 08335-7 1/2" 1.31 1.02 0.96 10/100 18.3 8336

Boxed

08336-4 3/4"

With Gasket

1.37 1.28 1.18 5/50 13.0

8335-G 08405-7 1/2" 1.31 1.02 0.96 10/100 19.2 8336-G 08414-9 3/4" 1.37 1.28 1.18 5/50 13.3

Teddico/BWF Pittsburgh, Pa. 15205 TE1=11311C13 BINF ELECTRICAL PRODUCTS I.M.Prm,

Use:Pull elbows are used to facilitate pulling

conductors through a 90° bend in a run of Rigid or

IMC conduit. The removable cover gives ample

access so that wire pulling can be achieved

without any obstructions.

• Removable Aluminum Cover

Materials • Zinc Die-Cast

• Neoprene Gasket

Certification E155411 LR57925

Standards UL 514B CSA C22.2 No. 18

NEMA FB-1 NEC Article 345 & 346

Rigid to Rigid Pull Elbows RIGID CONDUIT

Boxed W /O Gasket

A

C

B

Use:Pull elbows are used to facilitate pulling

conductors through a 90° bend in a run of Rigid or

IMC conduit. The removable cover gives ample

access so that wire pulling can be achieved

without any obstructions.

• Removable Aluminum Cover

Materials • Zinc Die-Cast

• Neoprene Gasket

Certification E155411 LR57925

Standards UL 514B CSA C22.2 No. 18

NEMA FB-1 NEC Article 345 & 346

Rigid to Box Pull Elbows RIGID CONDUIT

B

C

A

RIG

ID C

ON

DU

IT

Teddico/BWF Pittsburgh, Pa. 15205

Boxed W ith Gasket

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

8345 08345-6 1/2" 1.31 1.02 0.96 10/100 18.8

8346 08346-3 3/4" 1.37 1.28 1.26 5/50 13.3

8345-G 08359-3 1/2" 1.31 1.02 0.96 10/100 19.6

8346-G 08349-4 3/4" 1.37 1.28 1.26 5/50 13.7

8347-G 08347-0 1" 1.95 1.55 1.52 25 15.6

8348-G 08348-7 1 1/4" 2.32 1.92 1.88 20 18.8

Boxed W /O Gasket

Boxed W ith Gasket

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

8335 08335-7 1/2" 1.31 1.02 0.96 10/100 18.3

8336 08336-4 3/4" 1.37 1.28 1.18 5/50 13.0

8335-G 08405-7 1/2" 1.31 1.02 0.96 10/100 19.2

8336-G 08414-9 3/4" 1.37 1.28 1.18 5/50 13.3

5-3

Page 41: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Threaded Couplings

Use: Threaded couplings are used to join two lengths of threaded Rigid or IMC Conduit.

Materials • Steel

Finish • Galvanized

RIGID CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions Ctn/Case Case Qty/Qty Wt. A

Boxed 9000 09000-3 1/2" 1 5/8" 1" 100 12.6 9001 09001-0 3/4" 15/8" 11/4" 50 8.0 9002 09002-7 1" 2" 1 1/2" 30 8.3 9003 09003-4 11/4" 21/16" 17/8" 25 8.3 9004 09004-1 1 1/2" 2 1/8" 2 1/8" 25 11.0 9005 09005-0 2" 2 3/16" 2 5/8" 20 14.1 9006 09006-5 2 1/2" 3 3/16" 3 3/16" 12 20.4 9007 09007-2 3" 3 13/16" 3 1/4" 8 16.4 9008 09008-9 3 1/2" 4 1/2" 3 7/16" 4 10.6 9009 09009-6 4" 4 13/16"" 3 1/2" 4 13.9

T. R

IGID

CO

ND

UIT

Counduit Nipples

Use: Conduit nipples are used to terminate threaded conduit to a knock-out, outlet box or metal enclosure where room is limited, or with a locknut to connect two outlet boxes or metal enclosures side by side or back to back.

Materials • Zinc Die-Cast

Certification

E155411 LR57925

Standards UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 345 & 346

Counduit Nipples (Malleable Iron)

Use: Conduit nipples are used to terminate threaded conduit to a knock-out, outlet box or metal enclosure where room is limited, or with a locknut to connect two outlet boxes or metal enclosures side by side or back to back.

Materials • Malleable Iron

Certification

E155411 0• LR57925

RIGID CONDUIT Catalog Number

UPC No

0-87115

Trade Size

Nominal Dimensions A B C

Pcs/ Ctn/Case Case Unit Qty/Qty Wt.

Boxed 8220 08220-6 1/2" 0.93 0.59 0.44 100/1000 29.4 8221 08221-3 3/4" 1.19 0.71 0.50 50/500 28.4 8222 08222-0 1" 1.39 0.84 0.63 25/250 18.7 8223 08223-7 1 1/4" 1.75 0.87 0.63 25/250 27.7 8224 08224-4 1 1/2" 2.13 0.90 0.63 25/100 16.0 8225 08225-1 2" 2.56 1.01 0.72 10/40 9.1 8226 08226-8 2 1/2" 3.28 1.43 1.04 10/40 15.6 8227 08227-5 3" 2.13 0.90 0.63 10/40 19.2 8228 08228-2 3 1/2" 2.56 1.01 0.72 10/40 27.5 8229 08229-9 4" Boxed KV insulated throat

3.28 1.43 1.04 5/20 16.9

8230 08230-5 1/2" 0.93 0.59 0.44 100/1000 29.4 8231 08231-2 3/4" 1.19 0.71 0.50 50/500 28.4 8232 08232-9 1" 1.39 0.84 0.63 25/250 18.7 8233 08233-6 1 1/4" 1.75 0.87 0.63 25/250 27.7 8234 08234-3 1 1/2" 2.13 0.90 0.63 25/100 16.0 8235 08235-0 2" 2.56 1.01 0.72 10/40 9.1 8236 08236-7 2 1/2" 3.28 1.43 1.04 10/40 15.6 8237 08237-4 3" 2.13 0.90 0.63 10/40 19.2 8238 08238-1 3 1/2" 2.56 1.01 0.72 10/40 27.5 8239 08239-8 4" 3.28 1.43 1.04 5/20 16.9

RIGID CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions Pcs/ Ctn/Case Case

Qty/Qty Wt. A B C Unit

Boxed 9510 09510-7 1/2" 0.93 0.59 0.44 100/500 26.9 9511 09511-4 3/4" 1.19 0.71 0.50 50/250 20.0 9512 09512-1 1" 1.39 0.84 0.63 25/125 12.0 9513 09513-8 11/4" 1.75 0.87 0.63 25/125 28.9 9514 09514-5 1 1/2" 2.13 0.90 0.63 25/125 35.4 9515 09515-2 2" 2.56 1.01 0.72 10/40 16.4 9516 09516-9 2 1/2" 3.28 1.43 1.04 10 6.4 9517 09517-6 3" 2.13 0.90 0.63 10 10.0 9518 09518-3 3 1/2" 2.56 1.01 0.72 10 13.2 9519 09519-0 4" 3.28 1.43 1.04 5 8.9

BWF Teddico/BWF Pittsburgh, Pa. 15205

ELECTRICAL PRODUCTS "MI

Use:Threaded couplings are used to join two lengths of

threaded Rigid or IMC Conduit.

Materials• Steel

Finish • Galvanized

Threaded Couplings RIGID CONDUIT

Boxed

B A

RIG

ID C

ON

DU

IT

Teddico/BWF Pittsburgh, Pa. 15205

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B Qty/Qty Wt.

9000 09000-3 1/2" 1 5/8" 1" 100 12.6

9001 09001-0 3/4" 1 5/8" 1 1/4" 50 8.0

9002 09002-7 1" 2" 1 1/2" 30 8.3

9003 09003-4 1 1/4" 2 1/16" 1 7/8" 25 8.3

9004 09004-1 1 1/2" 2 1/8" 2 1/8" 25 11.0

9005 09005-0 2" 2 3/16" 2 5/8" 20 14.1

9006 09006-5 2 1/2" 3 3/16" 3 3/16" 12 20.4

9007 09007-2 3" 3 13/16" 3 1/4" 8 16.4

9008 09008-9 3 1/2" 4 1/2" 3 7/16" 4 10.6

9009 09009-6 4" 4 13/16"" 3 1/2" 4 13.9

5-4

Use:Conduit nipples are used to terminate threaded

conduit to a knock-out, outlet box or metal

enclosure where room is limited, or with a locknut

to connect two outlet boxes or metal enclosures

side by side or back to back.

Materials• Zinc Die-Cast

Certification E155411 LR57925

StandardsUL 514B CSA C22.2 No. 18

NEMA FB-1 NEC Article 345 & 346

Counduit Nipples RIGID CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8220 08220-6 1/2" 0.93 0.59 0.44 - 100/1000 29.4

8221 08221-3 3/4" 1.19 0.71 0.50 - 50/500 28.4

8222 08222-0 1" 1.39 0.84 0.63 - 25/250 18.7

8223 08223-7 1 1/4" 1.75 0.87 0.63 - 25/250 27.7

8224 08224-4 1 1/2" 2.13 0.90 0.63 - 25/100 16.0

8225 08225-1 2" 2.56 1.01 0.72 - 10/40 9.1

8226 08226-8 2 1/2" 3.28 1.43 1.04 - 10/40 15.6

C B

A

8227 08227-5 3" 2.13 0.90 0.63 - 10/40 19.2

8228 08228-2 3 1/2" 2.56 1.01 0.72 - 10/40 27.5

8229 08229-9 4" 3.28 1.43 1.04 - 5/20 16.9

8230 08230-5 1/2" 0.93 0.59 0.44 - 100/1000 29.4

8231 08231-2 3/4" 1.19 0.71 0.50 - 50/500 28.4

8232 08232-9 1" 1.39 0.84 0.63 - 25/250 18.7

8233 08233-6 1 1/4" 1.75 0.87 0.63 - 25/250 27.7

8234 08234-3 1 1/2" 2.13 0.90 0.63 - 25/100 16.0

8235 08235-0 2" 2.56 1.01 0.72 - 10/40 9.1

8236 08236-7 2 1/2" 3.28 1.43 1.04 - 10/40 15.6

8237 08237-4 3" 2.13 0.90 0.63 - 10/40 19.2

8238 08238-1 3 1/2" 2.56 1.01 0.72 - 10/40 27.5

8239 08239-8 4" 3.28 1.43 1.04 - 5/20 16.9

Boxed w/ insulated throat

RIGID CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9510 09510-7 1/2" 0.93 0.59 0.44 - 100/500 26.9

9511 09511-4 3/4" 1.19 0.71 0.50 - 50/250 20.0

9512 09512-1 1" 1.39 0.84 0.63 - 25/125 12.0

9513 09513-8 1 1/4" 1.75 0.87 0.63 - 25/125 28.9

9514 09514-5 1 1/2" 2.13 0.90 0.63 - 25/125 35.4

9515 09515-2 2" 2.56 1.01 0.72 - 10/40 16.4

9516 09516-9 2 1/2" 3.28 1.43 1.04 - 10 6.4

9517 09517-6 3" 2.13 0.90 0.63 - 10 10.0

9518 09518-3 3 1/2" 2.56 1.01 0.72 - 10 13.2

9519 09519-0 4" 3.28 1.43 1.04 - 5 8.9

Use:Conduit nipples are used to terminate threaded

conduit to a knock-out, outlet box or metal

enclosure where room is limited, or with a locknut

to connect two outlet boxes or metal enclosures

side by side or back to back.

Materials• Malleable Iron

Certification E155411 LR57925

Counduit Nipples

C B

A

(Malleable Iron)

Page 42: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Teddico/BWF Pittsburgh, Pa. 15205 TECICHICCD B F ELECTRICAL PRODUCTS 'IMMUrm,

• LR57925

Materials • Zinc Die-Cast Certification

E155411

Conduit Locknuts

A

Use: Conduit locknuts are used for securing Rigid and IMC Conduits and other threaded connectors to a steel outlet box or metal enclosure. Materials • Steel

Finish • Zinc Plated

Die-Cast Locknuts

Use: Conduit locknuts are used for securing Rigid and IMC Conduits and other threaded connectors to a steel outlet box or metal enclosure. • Single Cast Thread • Fully Reversible • Creates a 360° Ground path • UL Listed Stand Alone for Rigid Conduit

RIGID CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions Ctn/Case Case

Qty/Qty Wt. A B C

Boxed 131 70805-2 3/8" 1.12 0.09 1.00 100/1000 11.5 132 70810-6 1/2" 1.37 0.10 1.25 100/1000 11.4 133 70815-1 3/4" 1.75 0.12 1.56 100/1000 16.2 134 70820-5 1" 2.12 0.12 1.91 100/1000 27.2 149 70825-0 11/4" 2.43 0.12 2.16 50/500 18.9 150 70830-4 11/2" 2.93 0.12 2.68 50/500 25.2 151 70835-9 2" 3.56 0.17 3.25 40/400 29.3 152 70840-3 21/2" 4.18 0.17 3.95 30/300 44.4 153 70845-8 3" 5.37 0.17 5.00 25/250 43.0 154 70850-2 31/2" 2.93 0.12 2.68 25/125 18.3 155 70855-7 4" 3.56 0.17 3.25 20/100 26.0 156 70860-1 5" 4.18 0.17 3.95 10/30 23.5 157 70865-6 6" 5.37 0.17 5.00 10/30 26.5

RIGID CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions Ctn/Case Case

Qty/Qty Wt. A B

Boxed 8450 08450-2 1/2" 1.10 0.14 100/1000 10.5 8451 08451-9 3/4" 1.35 0.14 100/1000 11.3 8452 08452-6 1" 1.68 0.18 100/1000 20.7 8453 08453-3 1 1/4" 2.06 0.21 50/500 16.0 8454 08454-0 1 1/2" 2.38 0.21 20/200 9.7 8455 08455-7 2" 2.92 0.21 25/250 17.8 8456 08456-4 2 1/2" 3.52 0.29 10/100 12.2 8457 08457-6 3" 4.12 0.29 10/100 17.0 8458 08458-3 3 1/2" 4.67 0.31 10/50 8.7 8459 08459-0 4" 5.25 0.31 10/50 10.0

Standards UL 514B CSA C22.2 NEMA FB-1 NEC Article 345 & 346

Use:Conduit locknuts are used for securing Rigid and

IMC Conduits and other threaded connectors to a

steel outlet box or metal enclosure.

Materials • Steel

Finish • Zinc Plated

Conduit Locknuts RIGID CONDUIT

Boxed

A

B

C

Use:Conduit locknuts are used for securing Rigid and

IMC Conduits and other threaded connectors to a

steel outlet box or metal enclosure.

• Single Cast Thread

• Fully Reversible

• Creates a 360° Ground path

• UL Listed Stand Alone for Rigid Conduit

Materials• Zinc Die-Cast

Certification E155411 LR57925

Standards

Die-Cast Locknuts RIGID CONDUIT

Boxed

A

B

RIG

ID C

ON

DU

IT

Teddico/BWF Pittsburgh, Pa. 15205

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

131 70805-2 3/8" 1.12 0.09 1.00 100/1000 11.5132 70810-6 1/2" 1.37 0.10 1.25 100/1000 11.4133 70815-1 3/4" 1.75 0.12 1.56 100/1000 16.2134 70820-5 1" 2.12 0.12 1.91 100/1000 27.2149 70825-0 1 1/4" 2.43 0.12 2.16 50/500 18.9150 70830-4 1 1/2" 2.93 0.12 2.68 50/500 25.2151 70835-9 2" 3.56 0.17 3.25 40/400 29.3152 70840-3 2 1/2" 4.18 0.17 3.95 30/300 44.4153 70845-8 3" 5.37 0.17 5.00 25/250 43.0

154 70850-2 3 1/2" 2.93 0.12 2.68 25/125 18.3155 70855-7 4" 3.56 0.17 3.25 20/100 26.0156 70860-1 5" 4.18 0.17 3.95 10/30 23.5157 70865-6 6" 5.37 0.17 5.00 10/30 26.5

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Qty/Qty Wt.

100/1000 10.5

100/1000 11.3

100/1000 20.7

50/500 16.0

20/200 9.7

25/250 17.8

10/100 12.2

5-5

UL 514B CSA C22.2

NEMA FB-1

NEC Article 345 & 346

10/100 17.0

10/50 8.7

10/50 10.0

Number 0-87115 Size A B

8450 08450-2 1/2" 1.10 0.14

8451 08451-9 3/4" 1.35 0.14

8452 08452-6 1" 1.68 0.18

8453 08453-3 1 1/4" 2.06 0.21

8454 08454-0 1 1/2" 2.38 0.21

8455 08455-7 2" 2.92 0.21

8456 08456-4 2 1/2" 3.52 0.29

8457 08457-6 3" 4.12 0.29

8458 08458-3 3 1/2" 4.67 0.31

8459 08459-0 4" 5.25 0.31

Page 43: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

cn

R

IG

ID C

ON

DU

IT

Plastic Insulating Bushings

A

Use: Plastic insulating bushings are used on the end of Rigid and IMC Conduits and other threaded connectors to provide a smooth well rounded bearing surface to protect wires or cables. • Rated 105°C

• Flame Retardant

Materials • Thermoplastic

Finish • Grey Certification

oOus E121487

Standards UL 514B CSA C22.2 No. 18 NEMA FB-1

Insulated Metallic Grounding Bushings w/ Lay-In Lug

Insulated metallic grounding bushings are used on the end of Rigid and IMC Conduits and other threaded connectors to provide a smooth well rounded bearing surface to protect wires or cables as well as providing a means to connect a grounding conductor. • Nylon Liner Rated 150°C • 90°C Dual Rated Lay-in Aluminum Lug

Materials • Zinc Die-Cast Certification

0 E88878 • LR57925

Standards UL 467 CSA C22.2 No. 41 NEMA FB-1 NEC Article 345 & 346

TEDDICD BINF ELECTRICAL PRODUCTS 1.MWm,

RIGID CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions A B C

Ctn/Case Case

Qty/Qty Wt.

Boxed 171 09003-3 1/2" 1.04 0.39 0.60 100/1000 7.4 172 70710-9 3/4" 1.27 0.41 0.78 100/1000 9.7 173 70715-4 1" 1.55 0.56 1.00 50/500 9.6 174 70720-8 11/4" 1.90 0.57 1.33 25/250 7.4 175 70725-3 1 1/2" 2.18 0.57 1.54 50 1.9 176 70730-7 2" 3.17 0.73 2.36 50 2.3 177 70735-2 2 1/2" 3.17 0.73 2.36 25 2.0 178 70740-6 3" 3.80 0.76 3.00 25 2.4 179 70745-1 3 1/2" 3.80 0.76 3.00 25 2.4 170 70750-5 4" 3.80 0.76 3.00 25 2.4

RIGID CONDUIT Catalog Number

UPC No

0-87115

Trade Size

Nominal Dimensions Pcs/ Ctn/Case Case Qty/Qty Wt. A B C Unit

Boxed 8270 08270-1 1/2" 1.04 0.50 0.54 100/500 16.2 8271 08271-8 3/4" 1.28 0.50 0.74 50/250 21.5 8272 08272-5 1" 1.52 0.59 0.96 50/250 27.2 8273 08273-2 11/4" 1.87 0.61 1.27 25/125 13.5 8274 08274-9 11/2" 2.16 0.60 1.49 25/125 17.9 8275 08275-6 2" 2.67 0.60 1.95 10/50 22.9 8276 08276-3 2 1/2" 1.52 0.59 0.96 10 27.2 8277 08277-0 3" 1.87 0.61 1.27 5/25 13.5 8278 08278-7 3 1/2" 2.16 0.60 1.49 10 17.9 8279 08279-4 4" 2.67 0.60 1.95 10 22.9

Teddico/BWF Pittsburgh, Pa. 15205

Use:Plastic insulating bushings are used on the end of

Rigid and IMC Conduits and other threaded

connectors to provide a smooth well rounded

bearing surface to protect wires or cables.

• Rated 105°C

• Flame Retardant

Materials• Thermoplastic

Finish • Grey

Certification E121487

Standards UL 514B CSA C22.2 No. 18 NEMA FB-1

Plastic Insulating Bushings RIGID CONDUITCat

Number

Boxed171

172

173

174

175

176

177

178

A

C

B

179

170

Teddico/BWF Pittsburgh, Pa. 15205

RIG

ID C

ON

DU

IT

alog UPC No Trade Nominal Dimensions Ctn/Case Case

0-87115 Size A B C Qty/Qty Wt.

09003-3 1/2" 1.04 0.39 0.60 100/1000 7.4

70710-9 3/4" 1.27 0.41 0.78 100/1000 9.7

70715-4 1" 1.55 0.56 1.00 50/500 9.6

70720-8 1 1/4" 1.90 0.57 1.33 25/250 7.4

70725-3 1 1/2" 2.18 0.57 1.54 50 1.9

70730-7 2" 3.17 0.73 2.36 50 2.3

70735-2 2 1/2" 3.17 0.73 2.36 25 2.0

70740-6 3" 3.80 0.76 3.00 25 2.4

70745-1 3 1/2" 3.80 0.76 3.00 25 2.4

70750-5 4" 3.80 0.76 3.00 25 2.4

5-6

Use:Insulated metallic grounding bushings are used on the

end of Rigid and IMC Conduits and other threaded

connectors to provide a smooth well rounded bearing

surface to protect wires or cables as well as providing

a means to connect a grounding conductor.

• Nylon Liner Rated 150°C

• 90°C Dual Rated Lay-in Aluminum Lug

Materials • Zinc Die-Cast

Certification E88878 LR57925

Standards UL 467 CSA C22.2 No. 41

NEMA FB-1 NEC Article 345 & 346

Insulated Metallic GroundingBushings w/ Lay-In Lug

RIGID CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8270 08270-1 1/2" 1.04 0.50 0.54 - 100/500 16.2

8271 08271-8 3/4" 1.28 0.50 0.74 - 50/250 21.5

8272 08272-5 1" 1.52 0.59 0.96 - 50/250 27.2

8273 08273-2 1 1/4" 1.87 0.61 1.27 - 25/125 13.5

8274 08274-9 1 1/2" 2.16 0.60 1.49 - 25/125 17.9

8275 08275-6 2" 2.67 0.60 1.95 - 10/50 22.9

A

C

B

8276 08276-3 2 1/2" 1.52 0.59 0.96 - 10 27.2

8277 08277-0 3" 1.87 0.61 1.27 - 5/25 13.5

8278 08278-7 3 1/2" 2.16 0.60 1.49 - 10 17.9

8279 08279-4 4" 2.67 0.60 1.95 - 10 22.9

Page 44: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

(Malleable) Insulated Metallic Grounding Bushings w/ Lay-in Lug

Use: Insulated metallic grounding bushings are used on the end of Rigid and IMC Conduits and other threaded connectors to provide a smooth well rounded bearing surface to protect wires or cables as well as providing a means to connect a grounding conductor. • Nylon Liner Rated 150°C • 90°C Dual Rated Lay-in Aluminum Lug

Materials • Malleable Iron Certification

E88878•LR57925

RIGID CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions Pcs/ A B C Unit

Ctn/Case Case

Qty/Qty Wt.

Boxed 9560 09560-2 1/2" 1.04 0.50 0.54 100/500 49.0 9561 09561-9 3/4" 1.28 0.50 0.74 50/250 30.0 9562 09562-6 1" 1.52 0.59 0.96 50/250 44.0 9563 09563-3 1 1/4" 1.87 0.61 1.27 25/125 29.2 9564 09564-0 1 1/2" 2.16 0.60 1.49 25/125 35.6 9565 09565-7 2" 2.67 0.60 1.95 10/50 17.3 9566 09566-4 21/2" 1.52 0.59 0.96 10 5.60 9567 09567-1 3" 1.87 0.61 1.27 10 6.80 9568 09568-8 31/2" 2.16 0.60 1.49 10 7.80 9569 09569-5 4" 2.67 0.60 1.95 10 9.60

Standards UL 467

CSA C22.2 No. 41 NEMA FB-1 NEC Article 345 & 346

Reducing Bushings

Use: Reducing bushings are used to reduce the entry size of threaded conduit to allow joining conduits of two different sizes.

Materials • Zinc Die-Cast Certification

E155411 LR57925

Standards UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 345 & 346

RIGID CONDUIT Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed 8461 08461-2 3/4'-1/2" 0.62 0.80 0.12 50/500 20.2 8462 08462-9 1"-1/2" 0.70 1.00 0.13 25/250 27.9 8463 08463-6 1"-3/4" 0.70 1.00 0.13 25/250 32.7

Teddico/BWF Pittsburgh, Pa. 15205 BWF ELECTRICAL PRODUCTS 'IMEar

Use:Insulated metallic grounding bushings are used on the

end of Rigid and IMC Conduits and other threaded

connectors to provide a smooth well rounded bearing

surface to protect wires or cables as well as providing

a means to connect a grounding conductor.

• Nylon Liner Rated 150°C

• 90°C Dual Rated Lay-in Aluminum Lug

Materials • Malleable Iron

Certification E88878 LR57925

Standards UL 467 CSA C22.2 No. 41

NEMA FB-1 NEC Article 345 & 346

Insulated Metallic GroundingBushings w/ Lay-in Lug

RIGID CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9560 09560-2 1/2" 1.04 0.50 0.54 - 100/500 49.0

9561 09561-9 3/4" 1.28 0.50 0.74 - 50/250 30.0

9562 09562-6 1" 1.52 0.59 0.96 - 50/250 44.0

9563 09563-3 1 1/4" 1.87 0.61 1.27 - 25/125 29.2

9564 09564-0 1 1/2" 2.16 0.60 1.49 - 25/125 35.6

9565 09565-7 2" 2.67 0.60 1.95 - 10/50 17.3

A

C

B

9566 09566-4 2 1/2" 1.52 0.59 0.96 - 10 5.60

9567 09567-1 3" 1.87 0.61 1.27 - 10 6.80

9568 09568-8 3 1/2" 2.16 0.60 1.49 - 10 7.80

9569 09569-5 4" 2.67 0.60 1.95 - 10 9.60

Teddico/BWF Pittsburgh, Pa. 15205

RIG

ID C

ON

DU

IT

5-7

(Malleable)

Use:Reducing bushings are used to reduce the entry

size of threaded conduit to allow joining conduits

of two different sizes.

Materials • Zinc Die-Cast

Certification

E155411 LR57925

Standards UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 345 & 346

Reducing Bushings RIGID CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8461 08461-2 3/4'-1/2" 0.62 0.80 0.12 - 50/500 20.2

8462 08462-9 1"-1/2" 0.70 1.00 0.13 - 25/250 27.9

8463 08463-6 1"-3/4" 0.70 1.00 0.13 - 25/250 32.7

C A

B

Page 45: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

0 R

IG

ID C

ON

DU

IT

Reducing Bushings

Use: Reducing bushings are used to reduce the entry size of threaded conduit to allow joining conduits of two different sizes.

Materials • Steel

Certification

CC)US

E207875

Standards UL 514B NEMA FB-1

TEDDICD III

RIGID CONDUIT Catalog Number

UPC No Trade 0-87115 Size

Nominal Dimensions A B

Ctn/Case Case

Qty/Qty Wt.

Boxed - Steel 9630 09630-2 3/4"- 1/2" 1" 9/16" 100/500 22.0 9631 09631-9 1"- 1/2" 1 5/16" 5/8" 50/250 32.8 9632 09632-6 1"- 3/4" 1 5/16" 5/8" 50/250 18.8 9633 09633-3 1 1/4"- 1/2" 1 5/8" 3/4" 20/100 28.8 9634 09634-0 1 1/4"- 3/4" 1 5/8" 3/4" 20/100 21.9 9635 09635-7 1 1/4"- 1" 1 5/8" 3/4" 25/100 14.4 9636 09636-4 1 1/2"- 1/2" 1 7/8" 3/4" 10/50 20.3 9637 09637-1 1 1/2"- 3/4" 1 7/8" 3/4" 10/50 17.2 9638 09638-8 1 1/2"- 1" 1 7/8" 3/4" 10/50 12.9 9639 09639-5 1 1/2"- 1 1/4" 1 7/8" 3/4" 10/50 5.8 9640 09640-1 2"- 1" 2 5/16" 7/8" 10/50 33.2 9641 09641-8 2"- 1 1/4" 2 5/16" 7/8" 10/50 24.4 9642 09642-5 2"- 1 1/2"

Boxed - Malleable Iron

2 5/16" 7/8" 10/50 16.9

9643 09643-2 2 1/2"- 1" 2 7/8" 1 5/16" 5 6.3 9644 09644-9 2 1/2"- 1 1/4" 2 7/8" 1 5/16" 5 6.4 9645 09645-6 2 1/2"- 1 1/2" 2 7/8" 1 5/16" 5 5.3 9646 09646-3 2 1/2"- 2" 2 7/8" 1 5/16" 5 3.4 9647 09647-0 3"- 1" 3 7/16" 1 5/16" 5 9.5 9648 09648-7 3"- 1 1/4" 3 7/16" 1 5/16" 5 9.5 9649 09649-4 3"- 1 1/2" 3 7/16" 1 5/16" 5 8.1 9650 09650-0 3"- 2" 3 7/16" 1 5/16" 5 7.4 9651 09651-7 3"- 2 1/2" 3 7/16" 1 9/16" 5 5.9 9652 09652-4 3 1/2"- 2" 4" 1 1/2" 5 12.0 9653 09653-1 3 1/2"- 2 1/2" 4" 1 9/16" 5 11.7 9654 09654-8 3 1/2"- 3" 4" 1 5/8" 5 5.6 9655 09655-5 4"- 2" 4 7/16" 1 1/2" 5 15.2 9656 09656-2 4"- 2 1/2" 4 7/16" 1 1/2" 5 17.5 9657 09657-9 4"- 3" 4 7/16" 1 9/16" 5 11.9 9658 09658-6 4"- 3 1/2" 4 7/16" 1 3/4" 5 6.9 9659 09659-3 5"- 4" 5 1/2" 1 3/4" 1 3.8 9660 09660-9 6"- 5" 6 9/16" 1 3/4" 1 4.6

Teddico/BWF Pittsburgh, Pa. 15205 ELECTRICAL RFICOUCTS 'IMMUrm,

RIGID CONDUIT

Boxed - Steel

Teddico/BWF Pittsburgh, Pa. 15205

RIG

ID C

ON

DU

IT

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Qty/Qty Wt.

5-8

Use:Reducing bushings are used to reduce the entry

size of threaded conduit to allow joining conduits

of two different sizes.

Materials • Steel

Certification

Standards UL 514B

NEMA FB-1

Reducing Bushings

9640 09640-1 2"- 1"

9641 09641-8 2"- 1 1/4"

9642 09642-5 2"- 1 1/2"

Boxed - Malleable Iron

9643 09643-2 2 1/2"- 1"

9644 09644-9 2 1/2"- 1 1/4"

9645 09645-6 2 1/2"- 1 1/2"

9646 09646-3 2 1/2"- 2"

9647 09647-0 3"- 1"

9648 09648-7 3"- 1 1/4"

9649 09649-4 3"- 1 1/2"

9650 09650-0 3"- 2"

9651 09651-7 3"- 2 1/2"

9652 09652-4 3 1/2"- 2"

9653 09653-1 3 1/2"- 2 1/2"

9654 09654-8 3 1/2"- 3"

9655 09655-5 4"- 2"

9656 09656-2 4"- 2 1/2"

9657 09657-9 4"- 3"

9658 09658-6 4"- 3 1/2"

9659 09659-3 5"- 4"

9660 09660-9 6"- 5"

100/500 22.0

50/250 32.8

50/250 18.8

20/100 28.8

20/100 21.9

25/100 14.4

10/50 20.3

10/50 17.2

10/50 12.9

10/50 5.8

10/50 33.2

10/50 24.4

10/50 16.9

1 3.8

1 4.6

5 6.9

5 11.9

5 17.5

5 15.2

5 5.6

5 11.7

5 6.3

5 6.4

5 5.3

5 3.4

5 9.5

5 9.5

5 8.1

5 7.4

5 5.9

5 12.0

Number 0-87115 Size A B

9630 09630-2 3/4"- 1/2" 1" 9/16"

9631 09631-9 1"- 1/2" 1 5/16" 5/8"

9632 09632-6 1"- 3/4" 1 5/16" 5/8"

9633 09633-3 1 1/4"- 1/2" 1 5/8" 3/4"

9634 09634-0 1 1/4"- 3/4" 1 5/8" 3/4"

9635 09635-7 1 1/4"- 1" 1 5/8" 3/4"

9636 09636-4 1 1/2"- 1/2" 1 7/8" 3/4"

9637 09637-1 1 1/2"- 3/4" 1 7/8" 3/4"

9638 09638-8 1 1/2"- 1" 1 7/8" 3/4"

9639 09639-5 1 1/2"- 1 1/4" 1 7/8" 3/4"

2 5/16" 7/8"

2 5/16" 7/8"

2 5/16" 7/8"

2 7/8" 1 5/16"

2 7/8" 1 5/16"

2 7/8" 1 5/16"

2 7/8" 1 5/16"

3 7/16" 1 5/16"

3 7/16" 1 5/16"

3 7/16" 1 5/16"

3 7/16" 1 5/16"

3 7/16" 1 9/16"

4" 1 1/2"

4" 1 9/16"

4" 1 5/8"

4 7/16" 1 1/2"

4 7/16" 1 1/2"

4 7/16" 1 9/16"

4 7/16" 1 3/4"

5 1/2" 1 3/4"

6 9/16" 1 3/4"

Page 46: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Insulated Metallic Conduit Bushings

A

Use: Insulated Metallic Conduit bushings are used on the end of Rigid and IMC Conduits and other threaded connectors to provide a smooth well rounded bearing surface to protect wires or cables.

• Insulated version has 150°C rated Nylon insulator

Materials • Zinc Die-Cast Certification

• E155411 LR57925

Standards UL 514B

CSA C22.2 No. 18 NEMA FB-1 NEC Article 345 & 346

(Malleable Iron) Metallic Conduit Bushings

Use: Metallic Conduit bushings are used on the end of Rigid and IMC Conduits and other threaded connectors to provide a smooth well rounded bearing surface to protect wires or cables.

Materials • Malleable Iron Certification

• E155411 G LR57925

Standards UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 345 & 346

BWF ELECTRICAL PRODUCTS wr

Teddico/BWF Pittsburgh, Pa. 15205

RIGID CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions A B C

Ctn/Case Case

Qty/Qty Wt.

Boxed 8260 08260-2 1/2" 1.28 0.42 0.54 100/1000 29.9 8261 08261-9 3/4" 1.53 0.42 0.74 50/500 21.9 8262 08262-6 1" 1.86 0.5 0.96 25/250 15.4 8263 08263-3 1 1/4" 2.16 0.51 1.27 25/250 24.7 8264 08264-0 1 1/2" 2.63 0.52 1.49 10/100 11.9 8265 08265-7 2" 2.72 0.51 1.95 10/100 14.9 8266 08266-4 2 1/2" 3.22 0.83 2.32 10 2.8 8267 08267-1 3" 3.85 0.83 2.92 10 3.4 8268 08268-8 3 1/2" 3.22 0.83 2.32 10 3.9 8269 08269-5 4"

Boxed KV insulated throat

3.85 0.83 2.92 10 4.5

8250 08250-3 1/2" 1.28 0.42 0.54 100/1000 29.9 8251 08251-0 3/4" 1.53 0.42 0.74 50/500 21.9 8252 08252-7 1" 1.86 0.5 0.96 25/250 15.4 8253 08253-4 1 1/4" 2.16 0.51 1.27 25/250 24.7 8254 08254-1 1 1/2" 2.63 0.52 1.49 10/100 11.9 8255 08255-0 2" 2.72 0.51 1.95 10/100 14.9 8256 08256-5 2 1/2" 3.22 0.83 2.32 10 2.8 8257 08257-2 3" 3.85 0.83 2.92 10 3.5 8258 08258-9 3 1/2" 3.22 0.83 2.32 10 4.1 8259 08259-6 4" 3.85 0.83 2.92 10 4.7

RIGID CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions A B C

Ctn/Case Case

Qty/Qty Wt.

Boxed 9550 09550-8 1/2" 1.28 0.42 0.54 100/500 40.1 9551 09551-5 3/4" 1.53 0.42 0.74 50/250 24.9 9552 09552-2 1" 1.86 0.5 0.96 50/250 41.2 9553 09553-9 11/4" 2.16 0.51 1.27 25/125 31.5 9554 09554-6 11/2" 2.63 0.52 1.49 10/100 26.7 9555 09555-3 2" 2.72 0.51 1.95 10/100 33.3 9556 09556-0 21/2" 3.22 0.83 2.32 10 4.9 9557 09557-7 3" 3.85 0.83 2.92 10 6.3 9558 09558-4 3 1/2" 3.22 0.83 2.32 10 7.7 9559 09559-1 4" 3.85 0.83 2.92 10 9.3

Teddico/BWF Pittsburgh, Pa. 15205

RIG

ID C

ON

DU

IT

5-9

Use:Insulated Metallic Conduit bushings are used on the

end of Rigid and IMC Conduits and other threaded

connectors to provide a smooth well rounded

bearing surface to protect wires or cables.

• Insulated version has 150°C rated Nylon insulator

Materials • Zinc Die-Cast

Certification E155411 LR57925

Standards UL 514B CSA C22.2 No. 18

NEMA FB-1 NEC Article 345 & 346

Insulated Metallic Conduit BushingsRIGID CONDUIT

Cat

Number

Boxed8260

8261

8262

8263

8264

8265

8266

8267

A

C

B

8268

8269

8250

8251

8252

8253

8254

8255

8256

82578258

8259

Boxed w/ insulated throat

alog UPC No Trade Nominal Dimensions Ctn/Case Case

0-87115 Size A B C Qty/Qty Wt.

08260-2 1/2" 1.28 0.42 0.54 100/1000 29.9

08261-9 3/4" 1.53 0.42 0.74 50/500 21.9

08262-6 1" 1.86 0.5 0.96 25/250 15.4

08263-3 1 1/4" 2.16 0.51 1.27 25/250 24.7

08264-0 1 1/2" 2.63 0.52 1.49 10/100 11.9

08265-7 2" 2.72 0.51 1.95 10/100 14.9

08266-4 2 1/2" 3.22 0.83 2.32 10 2.8

08267-1 3" 3.85 0.83 2.92 10 3.408268-8 3 1/2" 3.22 0.83 2.32 10 3.9

08269-5 4" 3.85 0.83 2.92 10 4.5

08250-3 1/2" 1.28 0.42 0.54 100/1000 29.9

08251-0 3/4" 1.53 0.42 0.74 50/500 21.9

08252-7 1" 1.86 0.5 0.96 25/250 15.4

08253-4 1 1/4" 2.16 0.51 1.27 25/250 24.7

08254-1 1 1/2" 2.63 0.52 1.49 10/100 11.9

08255-0 2" 2.72 0.51 1.95 10/100 14.9

08256-5 2 1/2" 3.22 0.83 2.32 10 2.8

08257-2 3" 3.85 0.83 2.92 10 3.508258-9 3 1/2" 3.22 0.83 2.32 10 4.1

08259-6 4" 3.85 0.83 2.92 10 4.7

Use:

end of Rigid and IMC Conduits and other threaded

connectors to provide a smooth well rounded

bearing surface to protect wires or cables.

Materials • Malleable Iron

Certification E155411 LR57925

Standards UL 514B CSA C22.2 No. 18

NEMA FB-1 NEC Article 345 & 346

Metallic Conduit BushingsRIGID CONDUIT

Cat

Number

Boxed9550

9551

9552

9553

9554

9555

9556

9557

A

C

B

9558

9559

alog UPC No Trade Nominal Dimensions Ctn/Case Case

0-87115 Size A B C Qty/Qty Wt.

09550-8 1/2" 1.28 0.42 0.54 100/500 40.1

09551-5 3/4" 1.53 0.42 0.74 50/250 24.9

09552-2 1" 1.86 0.5 0.96 50/250 41.2

09553-9 1 1/4" 2.16 0.51 1.27 25/125 31.5

09554-6 1 1/2" 2.63 0.52 1.49 10/100 26.7

09555-3 2" 2.72 0.51 1.95 10/100 33.3

09556-0 2 1/2" 3.22 0.83 2.32 10 4.9

09557-7 3" 3.85 0.83 2.92 10 6.309558-4 3 1/2" 3.22 0.83 2.32 10 7.7

09559-1 4" 3.85 0.83 2.92 10 9.3

(Malleable Iron)

Metallic Conduit bushings are used on the

Page 47: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Reducing Washers

Use: Reducing washers are used to reduce the size of a knock-out in a steel outlet box or metal enclosure. Two reducing washers are required for each knock-out

• Rust Proof

• Embossed for Self-Centering Materials • Steel

Certification

E181788 LR104691

RIG

ID C

ON

DU

IT

02

TE1=1131C13 BWF

RIGID CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions A B C

Ctn/Case Case

Qty/Qty Wt.

Boxed 9200 09200-7 3/4"- 1/2" 0.87 1.44 0.04 100/1000 11.9 9201 09201-4 1"- 1/2" 0.87 1.75 0.04 250/2500 21.9 9202 09202-1 1"- 3/4" 1.11 1.75 0.04 100/1000 21.9 9203 09203-8 1 1/4"- 1/2" 0.87 2.18 0.04 50/500 16.9 9204 09204-5 1 1/4"- 3/4" 1.11 2.185 0.04 100/1000 16.9 9205 09205-0 1 1/4"- 1" 1.37 2.185 0.04 50/500 11.9 9206 09206-9 1 1/2"- 1/2" 0.87 2.44 0.04 50/500 26.9 9207 09207-6 1 1/2"- 3/4" 1.11 2.44 0.03 100/1000 26.9 9208 09208-3 1 1/2"- 1" 1.37 2.44 0.04 100/1000 39.4 9209 09209-0 1 1/2"- 1 1/4" 1.72 2.44 0.04 100/1000 39.4 9210 09210-6 2"- 1/2" 0.87 3.00 0.03 25/250 21.9 9211 09211-3 2"- 3/4" 1.11 3.00 0.04 25/250 21.9 9212 09212-0 2"- 1" 1.37 3.00 0.04 25/250 19.4 9213 09213-7 2"- 1 1/4" 1.72 3.00 0.04 25/250 19.4 9214 09214-4 2"- 1 1/2" 1.98 3.00 0.04 25/250 16.9 9215 09215-1 2 1/2"- 1/2" 0.87 3.50 0.04 25/250 21.9 9216 09216-8 2 1/2"- 3/4" 1.11 3.50 0.04 25/250 21.9 9217 09217-5 2 1/2"- 1" 1.37 3.50 0.04 25/250 19.4 9218 09218-0 2 1/2"- 1 1/4" 1.73 3.50 0.04 25/250 16.9 9219 09219-9 2 1/2"- 1 1/2" 1.98 3.50 0.04 25/250 14.4 9220 09220-5 2 1/2"- 2" 2.46 3.50 0.04 25/250 11.9 9221 09221-0 3"- 1/2" 0.88 4.13 0.04 25 6.0 9222 09222-9 3"- 3/4" 1.11 4.13 0.04 25 5.0 9223 09223-6 3"- 1" 1.37 4.13 0.04 25 5.0 9224 09224-3 3"- 1 1/4" 1.73 4.13 0.04 25 4.0 9225 09225-0 3"- 1 1/2" 1.98 4.13 0.04 25 3.0 9226 09226-7 3"- 2" 2.47 4.13 0.04 25 2.0 9227 09227-4 3"- 2 1/2" 2.97 4.13 0.04 25 2.0 9228 09228-1 3 1/2"- 1/2" 0.88 4.63 0.06 10 3.0 9229 09229-8 3 1/2"- 3/4" 1.11 4.63 0.06 10 3.0 9230 09230-3 3 1/2"- 1" 1.37 4.63 0.06 10 3.0 9231 09231-9 3 1/2" - 1 1/4" 1.73 4.63 0.06 10 3.0 9232 09232-5 3 1/2" - 1 1/2" 1.98 4.63 0.06 10 3.0 9233 09233-1 3 1/2" - 2" 2.47 4.63 0.06 10 3.0 9234 09234-4 3 1/2" - 2 1/2" 2.97 4.63 0.06 10 2.0 9235 09235-0 3 1/2" - 3" 3.59 4.63 0.06 10 2.0 9236 09236-6 4" - 1/2" 0.88 5.15 0.06 10 3.0 9237 09237-2 4" - 3/4" 1.11 5.15 0.06 10 3.0 9238 09238-8 4" - 1" 1.37 5.15 0.06 10 3.0 9239 09239-4 4" - 1 1/4" 1.73 5.15 0.06 10 2.0 9240 09240-9 4" - 1 1/2" 1.98 5.15 0.06 10 2.0 9241 09241-5 4" - 2" 2.47 5.15 0.06 10 2.0 9242 09242-1 4" - 2 1/2" 2.97 5.15 0.06 10 2.0 9243 09243-7 4" - 3" 3.59 5.15 0.06 10 2.0 9244 09244-0 4" - 3 1/2" 4.13 5.15 0.06 10 1.0

Teddico/BWF Pittsburgh, Pa. 15205 ELECTRICAL RFICOUCTS 'IMMUrm,

Use:Reducing washers are used to reduce the size of

a knock-out in a steel outlet box or metal

enclosure. Two reducing washers are required for

each knock-out

• Rust Proof

• Embossed for Self-Centering

Materials • Steel

Certification

Reducing Washers RIGID CONDUIT

Boxed

AB

C

Teddico/BWF Pittsburgh, Pa. 15205

RIG

ID C

ON

DU

IT

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

9200 09200-7 3/4"- 1/2" 0.87 1.44 0.04 100/1000 11.9

9201 09201-4 1"- 1/2" 0.87 1.75 0.04 250/2500 21.9

9202 09202-1 1"- 3/4" 1.11 1.75 0.04 100/1000 21.9

9203 09203-8 1 1/4"- 1/2" 0.87 2.18 0.04 50/500 16.9

9204 09204-5 1 1/4"- 3/4" 1.11 2.185 0.04 100/1000 16.9

9205 09205-0 1 1/4"- 1" 1.37 2.185 0.04 50/500 11.9

9206 09206-9 1 1/2"- 1/2" 0.87 2.44 0.04 50/500 26.9

9207 09207-6 1 1/2"- 3/4" 1.11 2.44 0.03 100/1000 26.9

9208 09208-3 1 1/2"- 1" 1.37 2.44 0.04 100/1000 39.4

9209 09209-0 1 1/2"- 1 1/4" 1.72 2.44 0.04 100/1000 39.4

9210 09210-6 2"- 1/2" 0.87 3.00 0.03 25/250 21.9

9211 09211-3 2"- 3/4" 1.11 3.00 0.04 25/250 21.9

9212 09212-0 2"- 1" 1.37 3.00 0.04 25/250 19.4

9213 09213-7 2"- 1 1/4" 1.72 3.00 0.04 25/250 19.4

9214 09214-4 2"- 1 1/2" 1.98 3.00 0.04 25/250 16.9

9215 09215-1 2 1/2"- 1/2" 0.87 3.50 0.04 25/250 21.9

9216 09216-8 2 1/2"- 3/4" 1.11 3.50 0.04 25/250 21.9

9217 09217-5 2 1/2"- 1" 1.37 3.50 0.04 25/250 19.4

9218 09218-0 2 1/2"- 1 1/4" 1.73 3.50 0.04 25/250 16.9

9219 09219-9 2 1/2"- 1 1/2" 1.98 3.50 0.04 25/250 14.4

9220 09220-5 2 1/2"- 2" 2.46 3.50 0.04 25/250 11.9

9221 09221-0 3"- 1/2" 0.88 4.13 0.04 25 6.0

9222 09222-9 3"- 3/4" 1.11 4.13 0.04 25 5.0

9223 09223-6 3"- 1" 1.37 4.13 0.04 25 5.0

9224 09224-3 3"- 1 1/4" 1.73 4.13 0.04 25 4.0

9225 09225-0 3"- 1 1/2" 1.98 4.13 0.04 25 3.0

9226 09226-7 3"- 2" 2.47 4.13 0.04 25 2.0

9227 09227-4 3"- 2 1/2" 2.97 4.13 0.04 25 2.0

9228 09228-1 3 1/2"- 1/2" 0.88 4.63 0.06 10 3.0

9229 09229-8 3 1/2"- 3/4" 1.11 4.63 0.06 10 3.0

9230 09230-3 3 1/2"- 1" 1.37 4.63 0.06 10 3.0

9231 09231-9 3 1/2" - 1 1/4" 1.73 4.63 0.06 10 3.0

9232 09232-5 3 1/2" - 1 1/2" 1.98 4.63 0.06 10 3.0

9233 09233-1 3 1/2" - 2" 2.47 4.63 0.06 10 3.0

9234 09234-4 3 1/2" - 2 1/2" 2.97 4.63 0.06 10 2.0

9235 09235-0 3 1/2" - 3" 3.59 4.63 0.06 10 2.0

9236 09236-6 4" - 1/2" 0.88 5.15 0.06 10 3.0

9237 09237-2 4" - 3/4" 1.11 5.15 0.06 10 3.0

9238 09238-8 4" - 1" 1.37 5.15 0.06 10 3.0

9239 09239-4 4" - 1 1/4" 1.73 5.15 0.06 10 2.0

9240 09240-9 4" - 1 1/2" 1.98 5.15 0.06 10 2.0

9241 09241-5 4" - 2" 2.47 5.15 0.06 10 2.0

9242 09242-1 4" - 2 1/2" 2.97 5.15 0.06 10 2.0

9243 09243-7 4" - 3" 3.59 5.15 0.06 10 2.0

9244 09244-0 4" - 3 1/2" 4.13 5.15 0.06 10 1.0

E181788 LR104691

5-10

Page 48: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Floor Flanges

Use: Used to support rigid conduit or IMC to the floor. Cast of high strength malleable iron and zinc plated.

Materials • Malleable Iron

RIGID CONDUIT Catalog UPC No Trade Ctn/Case Case Number 0-87115 Size Qty/Qty Wt.

Boxed 9540 09540-4 1/2" 25 6.6 9541 09541-1 3/4" 20 6.3 9542 09542-8 1" 20 9.1 9543 09543-5 1 1/4" 15 9.0 9544 09544-2 1 1/2" 12 8.8 9545 09545-9 2" 8 10.2

Offset Nipples

Use: Offset nipples are used to provide an offset connection between two outlet boxes or metal enclosures. • %" Axis Materials • Zinc Die-Cast Certification

E155411 LR57925

Standards UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 345 & 346

RIGID CONDUIT Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed 8302 08302-8 1/2" 2.42 0.94 0.42 10/100 10.5 8303 08303-5 3/4" 2.40 1.18 0.42 10/100 13.2 8304 08304-2 1" 2.72 1.40 0.60 10/100 21.2 8305 08305-9 1 1/4" 2.81 1.81 0.60 5/50 14.7 8306 08306-6 1 1/2" 3.00 2.00 0.68 5/50 20.2 8307 08307-3 2" 3.15 2.56 0.74 2/20 11.4

TECICIIC113 WillakrF Teddico/BWF Pittsburgh, Pa. 15205

W

Use:Offset nipples are used to provide an offset

connection between two outlet boxes or metal

enclosures.

• ¾" Axis

Materials • Zinc Die-Cast

Certification E155411 LR57925

Standards UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 345 & 346

Offset Nipples RIGID CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8302 08302-8 1/2" 2.42 0.94 0.42 - 10/100 10.5

8303 08303-5 3/4" 2.40 1.18 0.42 - 10/100 13.2

8304 08304-2 1" 2.72 1.40 0.60 - 10/100 21.2

8305 08305-9 1 1/4" 2.81 1.81 0.60 - 5/50 14.7

8306 08306-6 1 1/2" 3.00 2.00 0.68 - 5/50 20.2

8307 08307-3 2" 3.15 2.56 0.74 - 2/20 11.4

AC

B

Teddico/BWF Pittsburgh, Pa. 15205

RIG

ID C

ON

DU

IT

5-11

Use:Used to support rigid conduit or IMC to the floor.

Cast of high strength malleable iron and zinc

plated.

Materials • Malleable Iron

F loor F langes RIGID CONDUIT

Boxed

Catalog UPC No Trade Ctn/Case Case

Number 0-87115 Size Qty/Qty Wt.

9540 09540-4 1/2" 25 6.69541 09541-1 3/4" 20 6.39542 09542-8 1" 20 9.19543 09543-5 1 1/4" 15 9.09544 09544-2 1 1/2" 12 8.89545 09545-9 2" 8 10.2

Page 49: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

C

Watertight Conduit Hubs

Use: Watertight hubs are used to terminate threaded conduit to an outlet box or metal enclosure where a rain-tight, oil-tight or dust-tight connection is required.

• Assembled with 150° Rated Insulator and BUNA-N

• Oversized Locknut Provides Vibration-Proof Installation and Positive Grounding

• Listed for Use in Wet Locations

• Meets NEMA Sealing Requirements

• Certified for Use in Hazardous Locations

Materials • Zinc Die-Cast

RIGID CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions A B C

Ctn/Case Case

Qty/Qty Wt.

Boxed 8490 08490-3 1/2" 1.43 1.50 0.55 20/100 19.2 8491 08491-0 3/4" 1.68 1.50 0.74 20/100 26.1 8492 08492-7 1" 2.00 1.80 0.94 20/100 39.0 8493 08493-4 1 1/4" 2.37 1.80 1.28 10/50 26.4 8494 08494-1 1 1/2" 2.75 1.90 1.51 10/50 36.3 8495 08495-8 2" 3.25 1.90 1.97 5/25 23.6 8496 08496-5 2 1/2" 3.72 2.60 2.40 10 17.5 8497 08497-2 3" 5 11.0 8498 08498-9 31/2" 5 13.1 8499 08499-6 4" 5 13.8

Certification

E155411

LR57925

Standards UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 345 & 346

RIG

ID C

ON

DU

IT

NI

Watertight Conduit Hubs

Use: Watertight hubs are used to terminate threaded conduit to an outlet box or metal enclosure where a rain-tight, oil-tight or dust-tight connection is required. • Male hub thread - NPT

• Female thread for Rigid conduit and IMC - NPT

• Recessed o-ring seal assures watertight and dust tight connections

• Type NHUB with insulated throat and bonding locknut is suitable for service entrance application

Materials • Malleable Iron

Certification

E207875

• Suitable for use in hazardous locations as follows: Class I, Div. 2

Class II, Div. I , 2

Class Ill, Div. I , 2

Per NEC 501 -4(b), 502-

4(a), 503-3(a)

RIGID CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions A

Ctn/Case Case

Qty/Qty Wt.

Boxed 9800 09800-9 1/2" 13/16" 5/8" 1-1/2" 25/250 45.5 9801 09801-6 3/4" 15/16" 5/8" 1-13/16" 10/100 25.1 9802 09802-3 1" 1 1/16" 3/4" 2 1/16" 10/100 38.9 9803 09803-0 1 1/4" 1 1/4" 3/4" 2 5/8" 2/20 10.9 9804 09804-7 1 1/2" 1 1/4" 13/16" 3 1/8" 2/20 12.7 9805 09805-0 2" 1 1/4" 13/16" 3 9/16" 2/20 19.5 9806 09806-1 21/2" 15/8" 13/16" 41/8" 2 3.9 9807 09807-8 3" 1 3/4" 1 1/4" 4 15/16" 2 5.6 9808 09808-5 3 1/2" 1 13/16" 1 5/16" 5 3/4" 1 3.5 9809 09809-2 4" 1 15/16" 1 3/8" 6 3/16" 1 4.0 9810 09810-8 5" 2 1/16" 1 7/16" 7 5/8" 1 7.2 9811 09811-5 6" 2 1/8" 1 9/16" 8 13/16" 1 8.9

Standards UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 345 & 346

TECICOICCD BWF Teddico/BWF Pittsburgh, Pa. 15205

ELECTRICAL PRODUCTS W

Use:Watertight hubs are used to terminate threaded

conduit to an outlet box or metal enclosure where a

rain-tight, oil-tight or dust-tight connection is required.

• Assembled with 150° Rated Insulator and BUNA-N

• Oversized Locknut Provides Vibration-Proof

Installation and Positive Grounding

• Listed for Use in Wet Locations

• Meets NEMA Sealing Requirements

• Certified for Use in Hazardous Locations

Materials• Zinc Die-Cast

CertificationE155411 LR57925

Standards UL 514B

CSA C22.2 No. 18NEMA FB-1NEC Article 345 & 346

Watertight Conduit Hubs RIGID CONDUIT

Boxed

B

CA

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

8490 08490-3 1/2" 1.43 1.50 0.55 20/100 19.2

8491 08491-0 3/4" 1.68 1.50 0.74 20/100 26.1

8492 08492-7 1" 2.00 1.80 0.94 20/100 39.0

8493 08493-4 1 1/4" 2.37 1.80 1.28 10/50 26.4

8494 08494-1 1 1/2" 2.75 1.90 1.51 10/50 36.3

8495 08495-8 2" 3.25 1.90 1.97 5/25 23.6

8496 08496-5 2 1/2" 3.72 2.60 2.40 10 17.5

Teddico/BWF Pittsburgh, Pa. 15205

RIG

ID C

ON

DU

IT

Use:Watertight hubs are used to terminate threaded

conduit to an outlet box or metal enclosure where a

rain-tight, oil-tight or dust-tight connection is required.

Materials• Malleable Iron

Certification

Standards UL 514B

CSA C22.2 No. 18NEMA FB-1NEC Article 345 & 346

Watertight Conduit Hubs RIGID CONDUIT

Boxed

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

25/250 45.5

10/100 25.1

10/100 38.9

2/20 10.9

2/20 12.7

2/20 19.5

2 3.9

• Male hub thread - NPT

• Recessed o-ring seal assures watertightand dust tight connections

• Type NHUB with insulated throat and

bonding locknut is suitable for service

entrance application

• Female thread for Rigid conduit and IMC - NPT

Suitable for use in

hazardous locations as

follows:

Class I, Div. 2

Class II, Div. 1, 2

Class III, Div. 1, 2

Per NEC 501-4(b), 502-

4(a), 503-3(a)

E207875

9800 09800-9

9801 09801-6

9802 09802-3

9803 09803-0

9804 09804-7

9805 09805-0

9806 09806-1

1/2" 13/16" 5/8" 1-1/2"

3/4" 15/16" 5/8" 1-13/16"

1" 1 1/16" 3/4" 2 1/16"

1 1/4" 1 1/4" 3/4" 2 5/8"

1 1/2" 1 1/4" 13/16" 3 1/8"

2" 1 1/4" 13/16" 3 9/16"

2 1/2" 1 5/8" 1 3/16" 4 1/8"

3" 1 3/4" 1 1/4" 4 15/16"

3 1/2" 1 13/16" 1 5/16" 5 3/4"

4" 1 15/16" 1 3/8" 6 3/16"

5" 2 1/16" 1 7/16" 7 5/8"

6" 2 1/8" 1 9/16" 8 13/16"

2 5.69807 09807-8

1 3.59808 09808-5

1 4.09809 09809-2

1 7.29810 09810-8

1 8.99811 09811-5

5 11.0

5 13.1

5 13.8

5-12

8497 08497-2 3"

8498 08498-9 3 1/2"

8499 08499-6 4"

Page 50: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Service Entrance Ells RIGID CONDUIT Catalog UPC No Trade Nominal Dimensions Ctn/Case Case Number 0-87115 Size A B C Qty/Qty Wt.

Use: Service entrance ells are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance.

• Listed for Use in Wet Location

Materials • Die-Cast Aluminum

Certification

E121488 LR57925

Boxed 500 75005-1 1/2" 3.15 1.19 1.45 501 75010-5 3/4" 3.57 1.52 1.77 502 75015-0 1" 4.18 1.75 1.97 503 75020-4 1 1/4" 5.39 2.19 2.44 504 75025-9 1 1/2" 6.10 2.36 2.44 505 75030-3 2" 6.61 2.87 2.93 503-XL 71035-2 1 1/4" XL 7.83 2.48 2.95 505-XL 71040-6 2" XL 9.92 3.13 3.58

*XL Denotes Extra Long

38 8.0 36 8.0 12 6.0 12 11.5 10 10.0 4 5.5 5 6.0 5 14.0

Standards UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Articles 345 & 346

Mogul Conduit Bodies (Type LB) RIGID CONDUIT Catalog UPC No Trade Nominal Dimensions Ctn/Case Case Number 0-87115 Size A B C Qty/Qty Wt.

Boxed 603-MOG 28396-2 1 1/4" 9.61 2.51 2.78 604-MOG 28397-9 11/2" 14.48 3.24 5.31 605-MOG 28398-6 2" 14.48 3.24 5.34

2 1 1

3.8 4.9 4.5

Use: Mogul conduit bodies are used to gain greater access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction.

• Assembled with Cover and Gasket

• Meets NEC 6x Requirement

• Listed for Use in Wet Locations

Materials • Die-Cast Aluminum Certification

E121488 (11. LR57925

Standards UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 345 & 346

TEDDICD 131,VF ELECTRICAL 1.11111

.1r

Teddico/BWF Pittsburgh, Pa. 15205

Use:Service entrance ells are used to gain access to

the interior of a raceway for wire pulling,

inspection and maintenance.

• Listed for Use in Wet Location

Materials • Die-Cast Aluminum

Certification E121488 LR57925

Standards UL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Articles 345 & 346

Service Entrance Ells RIGID CONDUIT

Boxed

A

C

B

RIG

ID C

ON

DU

IT

Teddico/BWF Pittsburgh, Pa. 15205

Use:Mogul conduit bodies are used to gain greater access to

the interior of a raceway for wire pulling, inspection and

maintenance where the raceway changes direction.

• Assembled with Cover and Gasket

• Meets NEC 6x Requirement

• Listed for Use in Wet Locations

Materials • Die-Cast Aluminum

Certification E121488 LR57925

StandardsUL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 345 & 346

Mogul Conduit Bodies (Type LB) RIGID CONDUIT

Boxed

A

B

C500 75005-1 1/2" 3.15 1.19 1.45 38 8.0

501 75010-5 3/4" 3.57 1.52 1.77 36 8.0

502 75015-0 1" 4.18 1.75 1.97 12 6.0

503 75020-4 1 1/4" 5.39 2.19 2.44 12 11.5

504 75025-9 1 1/2" 6.10 2.36 2.44 10 10.0

505 75030-3 2" 6.61 2.87 2.93 4 5.5

503-XL 71035-2 1 1/4" XL 7.83 2.48 2.95 5 6.0

505-XL 71040-6 2" XL 9.92 3.13 3.58 5 14.0

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

*XL Denotes Extra Long

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

603-MOG 28396-2 1 1/4" 9.61 2.51 2.78 2 3.8

604-MOG 28397-9 1 1/2" 14.48 3.24 5.31 1 4.9

605-MOG 28398-6 2" 14.48 3.24 5.34 1 4.5

5-13

Page 51: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Use: Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction.

• Assembled with Cover and Gasket

A

Materials • Die-Cast Aluminum

Certification

E121488

4:1• LR57925

c 0 us E208392

Standards UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 345 & 346

RIG

ID C

ON

DU

IT

A

A

RIGID CONDUIT Threaded Aluminum Conduit Bodies

Catalog UPC No

Number 0-87115 Trade Size

Nominal Dimensions A B C

Pcs/ Ctn/Case Case Unit Qty/Qty Wt.

Boxed LB Type 600-CG 72205-8 1/2" 4.30 1.30 2.40 10/100 29.4 601-CG 72210-2 3/4" 5.00 1.50 2.60 10/50 22.0 602-CG 72215-7 1" 5.80 1.80 2.90 5/25 15.7 603-CG 72220-1 1 1/4" 7.80 2.50 3.70 2/10 12.9 604-CG 72225-6 1 1/2" 7.80 2.50 3.90 2/10 13.2 605-CG 72230-0 2" 9.80 3.20 4.70 1/5 13.4 606-CG 72231-7 2 1/2" 5.80 1.80 2.90 1 5.80 607-CG 72232-4 3" 7.80 2.50 3.70 1 6.00 608-CG 72233-1 3 1/2" 7.80 2.50 3.90 1 9.33 609-CG 72234-8

Boxed LR Type

4" 9.80 3.20 4.70 1 10.3

100-CG 72305-5 1/2" 4.40 2.10 1.60 10/100 31.8 101-CG 72310-9 3/4" 5.10 2.30 1.90 10/50 21.0 102-CG 72315-4 1" 5.80 2.50 2.10 5/25 17.5 103-CG 72320-8 11/4" 7.80 3.40 2.90 2/10 15.0 104-CG 72325-3 11/2" 7.80 3.40 2.90 2/10 14.1 105-CG 72330-7 2" 9.90 4.00 3.70 1/5 13.1 106-CG 71241-7 21/2" 5.80 2.50 2.10 1 5.71 107-CG 71246-2 3" 7.80 3.40 2.90 1 6.33 108-CG 19163-2 3 1/2" 7.80 3.40 2.90 1 11.2 109-CG 71256-1

Boxed LL Type

4" 9.90 4.00 3.70 1 10.2

200-CG 72405-2 1/2" 4.40 2.10 1.60 10/100 30.6 201-CG 72410-6 3/4" 5.10 2.30 1.90 10/50 21.0 202-CG 72415-1 1" 5.80 2.50 2.10 5/25 16.8 203-CG 72420-5 1 1/4" 7.80 3.40 2.90 2/10 15.0 204-CG 72421-2 1 1/2" 7.80 3.40 2.90 2/10 13.8 205-CG 72422-9 2" 9.90 4.00 3.70 1/5 14.4 206-CG 19622-4 2 1/2" 5.80 2.50 2.10 1 5.71 207-CG 19623-1 3" 7.80 3.40 2.90 1 6.83 208-CG 19624-8 3 1/2" 7.80 3.40 2.90 1 11.0 209-CG 21007-4

Boxed T Type

4" 9.90 4.00 3.70 1 10.3

700-CG 72605-6 1/2" 4.80 2.10 1.60 10/100 32.0 701-CG 72610-0 3/4" 5.50 2.30 1.90 10/50 21.7 702-CG 72615-5 1" 6.20 2.50 2.10 5/25 14.6 703-CG 72616-2 1 1/4" 8.30 3.40 2.90 2/10 17.5 704-CG 72625-4 1 1/2" 8.30 3.40 2.90 2/10 15.8 705-CG 72630-8 2" 10.20 4.00 3.70 2 5.50 706-CG 19566-1 21/2" 6.20 2.50 2.10 1 6.00 707-CG 19567-8 3" 8.30 3.40 2.90 1 6.50 708-CG 19568-5 31/2" 8.30 3.40 2.90 1 12.6 709-CG 19569-2

Boxed C Type

4" 10.20 4.00 3.70 1 10.6

300-CG 72505-9 1/2" 4.80 1.30 1.60 10/100 30.6 301-CG 72510-3 3/4" 5.50 1.50 1.90 10/50 21.3 302-CG 72515-8 1" 6.20 1.80 2.10 5/25 16.6 303-CG 72520-2 11/4" 8.30 2.50 2.90 2/10 15.0 304-CG 72525-7 11/2" 8.30 2.50 2.90 2/10 13.8 305-CG 15704-1 2" 10.20 3.20 3.70 1/5 12.5 306-CG 15684-6 2 1/2" 6.20 1.80 2.10 1 5.66 307-CG 15690-7 3" 8.30 2.50 2.90 1 6.33 308-CG 15696-9 31/2" 8.30 2.50 2.90 1 10.7 309-CG 15704-1

Boxed X Type

4" 10.20 3.20 3.70 1 9.67

400-CG 72630-8 1/2" 4.75 1.30 1.60 10/100 37.1 401-CG 72631-5 3/4" 5.50 1.50 1.90 10/50 27.0 402-CG 72632-2 1" 6.20 1.80 2.10 5/25 17.9 403-CG 72633-9 11/4" 8.30 2.50 2.90 2/10 13.6 404-CG 72634-6 11/2" 8.30 2.50 2.90 2/10 13.6 405-CG 72635-0 2" 10.20 3.20 3.70 2 4.86

TEDDICD 131,VF Teddico/BWF Pittsburgh, Pa. 15205

ELECTRICAL F-F,n,1L11-. I ‘ 111111111.

Use:

direction.

Materials • Die-Cast Aluminum

Certification

StandardsUL 514B

CSA C22.2 No. 18

NEMA FB-1NEC Article 345 & 346

RIGID CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed LB Type

600-CG 72205-8 1/2" 4.30 1.30 2.40 - 10/100 29.4

601-CG 72210-2 3/4" 5.00 1.50 2.60 - 10/50 22.0

602-CG 72215-7 1" 5.80 1.80 2.90 - 5/25 15.7

603-CG 72220-1 1 1/4" 7.80 2.50 3.70 - 2/10 12.9

604-CG 72225-6 1 1/2" 7.80 2.50 3.90 - 2/10 13.2

605-CG 72230-0 2" 9.80 3.20 4.70 - 1/5 13.4

Boxed LR Type

100-CG 72305-5 1/2" 4.40 2.10 1.60 - 10/100 31.8

101-CG 72310-9 3/4" 5.10 2.30 1.90 - 10/50 21.0

102-CG 72315-4 1" 5.80 2.50 2.10 - 5/25 17.5

103-CG 72320-8 1 1/4" 7.80 3.40 2.90 - 2/10 15.0

104-CG 72325-3 1 1/2" 7.80 3.40 2.90 - 2/10 14.1

105-CG 72330-7 2" 9.90 4.00 3.70 - 1/5 13.1

Boxed LL Type

200-CG 72405-2 1/2" 4.40 2.10 1.60 - 10/100 30.6

201-CG 72410-6 3/4" 5.10 2.30 1.90 - 10/50 21.0

202-CG 72415-1 1" 5.80 2.50 2.10 - 5/25 16.8

203-CG 72420-5 1 1/4" 7.80 3.40 2.90 - 2/10 15.0

204-CG 72421-2 1 1/2" 7.80 3.40 2.90 - 2/10 13.8

205-CG 72422-9 2" 9.90 4.00 3.70 - 1/5 14.4

Boxed T Type

700-CG 72605-6 1/2" 4.80 2.10 1.60 - 10/100 32.0

701-CG 72610-0 3/4" 5.50 2.30 1.90 - 10/50 21.7

702-CG 72615-5 1" 6.20 2.50 2.10 - 5/25 14.6

703-CG 72616-2 1 1/4" 8.30 3.40 2.90 - 2/10 17.5

704-CG 72625-4 1 1/2" 8.30 3.40 2.90 - 2/10 15.8

705-CG 72630-8 2" 10.20 4.00 3.70 - 2 5.50

Boxed C Type

300-CG 72505-9 1/2" 4.80 1.30 1.60 - 10/100 30.6

301-CG 72510-3 3/4" 5.50 1.50 1.90 - 10/50 21.3

302-CG 72515-8 1" 6.20 1.80 2.10 - 5/25 16.6

303-CG 72520-2 1 1/4" 8.30 2.50 2.90 - 2/10 15.0

304-CG 72525-7 1 1/2" 8.30 2.50 2.90 - 2/10 13.8

305-CG 15704-1 2" 10.20 3.20 3.70 - 1/5 12.5

Teddico/BWF Pittsburgh, Pa. 15205

RIG

ID C

ON

DU

IT

Boxed X Type

400-CG 72630-8 1/2" 4.75 1.30 1.60 - 10/100 37.1

401-CG 72631-5 3/4" 5.50 1.50 1.90 - 10/50 27.0

402-CG 72632-2 1" 6.20 1.80 2.10 - 5/25 17.9

403-CG 72633-9 1 1/4" 8.30 2.50 2.90 - 2/10 13.6

404-CG 72634-6 1 1/2" 8.30 2.50 2.90 - 2/10 13.6

405-CG 72635-0 2" 10.20 3.20 3.70 - 2 4.86

5-14

A

B

C

A

B C

A

B

C

A

B C

A

B

C

606-CG 72231-7 2 1/2" 5.80 1.80 2.90 - 1 5.80

607-CG 72232-4 3" 7.80 2.50 3.70 - 1 6.00

608-CG 72233-1 3 1/2" 7.80 2.50 3.90 - 1 9.33

609-CG 72234-8 4" 9.80 3.20 4.70 - 1 10.3

106-CG 71241-7 2 1/2" 5.80 2.50 2.10 - 1 5.71

107-CG 71246-2 3" 7.80 3.40 2.90 - 1 6.33

108-CG 19163-2 3 1/2" 7.80 3.40 2.90 - 1 11.2

109-CG 71256-1 4" 9.90 4.00 3.70 - 1 10.2

206-CG 19622-4 2 1/2" 5.80 2.50 2.10 - 1 5.71

207-CG 19623-1 3" 7.80 3.40 2.90 - 1 6.83

208-CG 19624-8 3 1/2" 7.80 3.40 2.90 - 1 11.0

209-CG 21007-4 4" 9.90 4.00 3.70 - 1 10.3

706-CG 19566-1 2 1/2" 6.20 2.50 2.10 - 1 6.00

707-CG 19567-8 3" 8.30 3.40 2.90 - 1 6.50

708-CG 19568-5 3 1/2" 8.30 3.40 2.90 - 1 12.6

709-CG 19569-2 4" 10.20 4.00 3.70 - 1 10.6

306-CG 15684-6 2 1/2" 6.20 1.80 2.10 - 1 5.66

307-CG 15690-7 3" 8.30 2.50 2.90 - 1 6.33

308-CG 15696-9 3 1/2" 8.30 2.50 2.90 - 1 10.7

309-CG 15704-1 4" 10.20 3.20 3.70 - 1 9.67

Conduit bodies are used

interior of a raceway for

and maintenance where

LR57925

E121488

to gain access to the

wire pulling, inspection

the raceway changes

Assembled with Cover and Gasket

Threaded A luminum Conduit Bodies

Page 52: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Threaded Malleable Iron Conduit Bodies

RIGID CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions Pcs/ A B C Unit

Ctn/Case Case Qty/Qty Wt.

Boxed LB Type M600 15800-0 1/2" 4.30 1.30 2.40 10 7.1 M601 15801-7 3/4" 5.00 1.50 2.60 10 9.7 M602 15802-4 1" 5.80 1.80 2.90 10 14.3 M603 15803-0 1 1/4" 7.80 2.50 3.70 10 28.7 M604 15804-8 1 1/2" 7.80 2.50 3.90 10 33.2 M605

Boxed LR Type

15805-0 2" 9.80 3.20 4.70 5 26.7

M100 15830-6 1/2" 4.40 2.10 1.60 10 7.1 M101 15831-2 3/4" 5.10 2.30 1.90 10 10.0 M102 15832-8 1" 5.80 2.50 2.10 10 15.7 M103 15833-4 1" 1/4" 7.80 3.40 2.90 10 33.2 M104 15834-7 1" 1/2" 7.80 3.40 2.90 10 34.5 M105

Boxed LL Type

15835-3 2" 9.90 4.00 3.70 5 31.3

M200 15820-8 1/2" 4.40 2.10 1.60 10 7.6 M201 15821-0 3/4" 5.10 2.30 1.90 10 9.5 M202 15822-2 1" 5.80 2.50 2.10 10 13.8 M203 15823-9 11/4" 7.80 3.40 2.90 10 30.9 M204 15824-6 11/2" 7.80 3.40 2.90 10 33.2 M205

Boxed T Type

15825-3 2" 9.90 4.00 3.70 5 24.9

M700 15840-2 1/2" 4.80 2.10 1.60 10 11.1 M701 15841-8 3/4" 5.50 2.30 1.90 10 13.7 M702 15842-4 1" 6.20 2.50 2.10 10 19.6 M703 15843-0 11/4" 8.30 3.40 2.90 10 33.2 M704 15844-3 11/2" 8.30 3.40 2.90 10 36.8 M705

Boxed C Type

15845-9 2" 10.20 4.00 3.70 2 13.3

M300 15810-9 1/2" 4.80 1.30 1.60 10 9.8 M301 15811-6 3/4" 5.50 1.50 1.90 10 11.8 M302 15812-3 1" 6.20 1.80 2.10 10 17.0 M303 15813-0 11/4" 8.30 2.50 2.90 10 30.9 M304 15814-7 11/2" 8.30 2.50 2.90 10 36.8 M305

Boxed X Type

15815-4 2" 10.20 3.20 3.70 5 27.6

M400 15860-4 1/2" 5.44 2.81 1.75 10 13.9 M401 15861-1 3/4" 6.06 2.94 2.00 10 17.2 M402 15862-8 1" 7.13 3.56 2.25 10 24.7 M403 15863-5 1 1/4" 9.13 4.44 2.56 10 41.6 M404 15864-2 1 1/2" 9.13 4.44 2.75 10 46.3 M405 15865-0 2" 11.75 5.38 3.44 2 16.7

Stamped Steel Covers LENGTH WIDTH THICKNESS

SSC-1 15850-8 1/2" 3.88 1.31 0.25 - 25/250 23.5 SSC-2 15851-4 3/4" 4.63 1.50 0.31 25/250 31.3 SSC-3 15852-0 1" 5.31 1.75 0.31 10/100 18.8 SSC-4 15853-6 1 1/4"-1 1/2" 7.19 2.50 0.38 25 7.80 SSC-5 15854-9 2" 9.50 3.19 0.50 25 12.5

Neoprene Gaskets LENGTH WIDTH NG-1 33627-9 1/2" 3.88 1.31 2500 27.0 NG-2 33628-6 3/4" 4.69 1.56 1000 13.0 NG-3 33629-3 1" 5.38 1.75 500 11.0 NG-4 33626-2 1 1/4"-1 1/2" 7.31 2.50 500 19.5 NG-5 33630-9 2" 9.50 3.13 125 11.0

Use: Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction.

*2 1/2" - 4" Available upon request except "X" type.

Materials • Malleable iron • Raised Dome Stamped Steel Covers • Neoprene Gaskets Certification

E121488•LR57925

Standards UL 514B CSA C22.2 No. 18 NEMA FB-1 NEC Article 345 & 346

-rscicli=ci Teddico/BWF Pittsburgh, Pa. 15205 ELECTRICAL PRODUCTS

Use:Conduit bodies are used to gain access to the

interior of a raceway for wire pulling, inspection

and maintenance where the raceway changes

direction.

Materials • Malleable iron

Certification E121488 LR57925

StandardsUL 514B

CSA C22.2 No. 18

NEMA FB-1

NEC Article 345 & 346

Threaded Malleable Iron RIGID CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed LB Type

M600 15800-0 1/2" 4.30 1.30 2.40 - 10 7.1

M601 15801-7 3/4" 5.00 1.50 2.60 - 10 9.7

M602 15802-4 1" 5.80 1.80 2.90 - 10 14.3

M603 15803-0 1 1/4" 7.80 2.50 3.70 - 10 28.7

M604 15804-8 1 1/2" 7.80 2.50 3.90 - 10 33.2

M605 15805-0 2" 9.80 3.20 4.70 - 5 26.7

Boxed LR Type

M100 15830-6 1/2" 4.40 2.10 1.60 - 10 7.1

M101 15831-2 3/4" 5.10 2.30 1.90 - 10 10.0

M102 15832-8 1" 5.80 2.50 2.10 - 10 15.7

M103 15833-4 1" 1/4" 7.80 3.40 2.90 - 10 33.2

M104 15834-7 1" 1/2" 7.80 3.40 2.90 - 10 34.5

M105 15835-3 2" 9.90 4.00 3.70 - 5 31.3

Boxed LL Type

M200 15820-8 1/2" 4.40 2.10 1.60 - 10 7.6

M201 15821-0 3/4" 5.10 2.30 1.90 - 10 9.5

M202 15822-2 1" 5.80 2.50 2.10 - 10 13.8

M203 15823-9 1 1/4" 7.80 3.40 2.90 - 10 30.9

M204 15824-6 1 1/2" 7.80 3.40 2.90 - 10 33.2

M205 15825-3 2" 9.90 4.00 3.70 - 5 24.9

Boxed T Type

M700 15840-2 1/2" 4.80 2.10 1.60 - 10 11.1

M701 15841-8 3/4" 5.50 2.30 1.90 - 10 13.7

M702 15842-4 1" 6.20 2.50 2.10 - 10 19.6

M703 15843-0 1 1/4" 8.30 3.40 2.90 - 10 33.2

M704 15844-3 1 1/2" 8.30 3.40 2.90 - 10 36.8

M705 15845-9 2" 10.20 4.00 3.70 - 2 13.3

Boxed C Type

M300 15810-9 1/2" 4.80 1.30 1.60 - 10 9.8

M301 15811-6 3/4" 5.50 1.50 1.90 - 10 11.8

M302 15812-3 1" 6.20 1.80 2.10 - 10 17.0

M303 15813-0 1 1/4" 8.30 2.50 2.90 - 10 30.9

M304 15814-7 1 1/2" 8.30 2.50 2.90 - 10 36.8

M305 15815-4 2" 10.20 3.20 3.70 - 5 27.6

Conduit B odie s

Teddico/BWF Pittsburgh, Pa. 15205

RIG

ID C

ON

DU

IT

Boxed X Type

M400 15860-4 1/2" 5.44 2.81 1.75 - 10 13.9

M401 15861-1 3/4" 6.06 2.94 2.00 - 10 17.2

M402 15862-8 1" 7.13 3.56 2.25 - 10 24.7

M403 15863-5 1 1/4" 9.13 4.44 2.56 - 10 41.6

M404 15864-2 1 1/2" 9.13 4.44 2.75 - 10 46.3

M405 15865-0 2" 11.75 5.38 3.44 - 2 16.7

*2 1/2" - 4" Available upon request except "X" type.

5-15

• Raised Dome Stamped Steel Covers• Neoprene Gaskets

Stamped Steel Covers

SSC-1 15850-8 1/2" 3.88 1.31 0.25 - 25/250 23.5

SSC-2 15851-4 3/4" 4.63 1.50 0.31 - 25/250 31.3

SSC-3 15852-0 1" 5.31 1.75 0.31 - 10/100 18.8

SSC-4 15853-6 1 1/4"-1 1/2" 7.19 2.50 0.38 - 25 7.80

SSC-5 15854-9 2" 9.50 3.19 0.50 - 25 12.5

Neoprene Gaskets

LENGTH WIDTH THICKNESS

NG-1 33627-9 1/2" 3.88 1.31 - 2500 27.0

NG-2 33628-6 3/4" 4.69 1.56 - 1000 13.0

NG-3 33629-3 1" 5.38 1.75 - 500 11.0

NG-4 33626-2 1 1/4"-1 1/2" 7.31 2.50 - 500 19.5

NG-5 33630-9 2" 9.50 3.13 - 125 11.0

LENGTH WIDTH

Page 53: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Rigid Threaded Nipples

Use: Threaded nipples are used to extend a length of threaded Rigid or IMC Conduit according to the pipe size and length desired. May also be used to connect two steel outlet boxes or metal enclosures together.

Materials • Zinc Plated Steel

RIGID CONDUIT

_.. R

IG

ID C

ON

DU

IT

-rscicsiccs

Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions A B

Ctn/Case Case

Qty/Qty Wt.

Boxed 9700 09700-2 1/2" Close 13/16" 25 2.20 9701 09701-9 1/2" 1-1/2" 13/16" 25 2.38 9702 09702-6 1/2" 2" 13/16" 25 3.30 9703 09703-3 1/2" 2-1/2" 13/16" 25 4.08 9704 09704-0 1/2" 3" 13/16" 25 4.95 9705 09705-7 1/2" 3-1/2" 13/16" 25 6.08 9706 09706-4 1/2" 4" 13/16" 25 6.90 9707 09707-1 1/2" 5" 13/16" 25 8.50 9708 09708-8 1/2" 6" 13/16" 1 0.49 9709 09709-5 1/2" 8" 13/16" 1 0.55 9710 09710-1 1/2" 10" 13/16" 1 0.70 9711 09711-8 1/2" 12" 13/16" 1 0.84 9712 09712-5 3/4" Close 1-1/16" 25 3.03 9713 09713-2 3/4" 2" 1-1/16" 25 3.58 9714 09714-9 3/4" 2-1/2" 1-1/16" 25 4.68 9715 09715-6 3/4" 3" 1-1/16" 25 5.80 9716 09716-3 3/4" 3-1/2" 1-1/16" 25 7.18 9717 09717-0 3/4" 4" 1-1/16" 25 8.28 9718 09718-7 3/4" 5" 1-1/16" 25 10.5 9719 09719-4 3/4" 6" 1-1/16" 1 0.53 9720 09720-0 3/4" 8" 1-1/16" 1 0.70 9721 09721-7 3/4" 10" 1-1/16" 1 0.88 9722 09722-4 3/4" 12" 1-1/16" 1 1.06 9723 09723-1 1" Close 1-5/16" 25 3.58 9724 09724-8 1" 2" 1-5/16" 25 4.40 9725 09725-5 1" 2-1/2" 1-5/16" 25 6.60 9726 09726-2 1" 3" 1-5/16" 25 8.28 9727 09727-9 1" 3-1/2" 1-5/16" 25 9.93 9728 09728-6 1" 4" 1-5/16" 25 11.6 9729 09729-3 1" 5" 1-5/16" 25 14.9 9730 09730-9 1" 6" 1-5/16" 25 18.1 9731 09731-6 1" 8" 1-5/16" 1 0.99 9732 09732-3 1" 10" 1-5/16" 1 1.25 9733 09733-0 1" 12" 1-5/16" 1 1.52 9734 09734-7 1-1/4" Close 1-11/16" 25 4.95 9735 09735-4 1-1/4" 2" 1-11/16" 25 5.53 9736 09736-1 1-1/4" 2-1/2" 1-11/16" 25 8.28 9737 09737-8 1-1/4" 3" 1-11/16" 25 10.5 9738 09738-5 1-1/4" 3-1/2" 1-11/16" 25 14.3 9739 09739-2 1-1/4" 4" 1-11/16" 25 15.4 9740 09740-8 1-1/4" 5" 1-11/16" 25 19.9 9741 09741-5 1-1/4" 6" 1-11/16" 25 23.7 9742 09742-2 1-1/4" 8" 1-11/16" 1 1.35 9743 09743-9 1-1/4" 10" 1-11/16" 1 1.72 9744 09744-6 1-1/4" 12" 1-11/16" 1 2.07 9745 09745-3 1-1/2" Close 1-7/8" 25 5.53 9746 09746-0 1-1/2" 2" 1-7/8" 25 6.08 9747 09747-7 1-1/2" 2-1/2" 1-7/8" 25 8.28 9748 09748-4 1-1/2" 3" 1-7/8" 25 11.0 9749 09749-1 1-1/2" 3-1/2" 1-7/8" 25 13.2 9750 09750-7 1-1/2" 4" 1-7/8" 25 16.5 9751 09751-4 1-1/2" 5" 1-7/8" 25 21.5 9752 09752-1 1-1/2" 6" 1-7/8" 1 1.08 9753 09753-8 1-1/2" 8" 1-7/8" 1 1.52 9754 09754-5 1-1/2" 10" 1-7/8" 1 1.96 9755 09755-2 1-1/2" 12" 1-7/8" 1 2.38

Teddico/BWF Pittsburgh, Pa. 15205 ELECTRICAL ARC/DUCTS

Use:Threaded nipples are used to extend a length of

threaded Rigid or IMC Conduit according to the

pipe size and length desired. May also be used to

connect two steel outlet boxes or metal enclosures

together.

Materials • Zinc Plated Steel

Rigid Threaded Nipples

RIGID CONDUIT

Boxed

Teddico/BWF Pittsburgh, Pa. 15205

RIG

ID C

ON

DU

IT

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Qty/Qty Wt.Number 0-87115 Size A B

25 2.20

25 2.38

25 3.30

25 4.08

25 4.95

25 6.08

25 6.90

25 8.50

1 0.49

1 0.55

1 0.70

25 3.03

25 3.58

25 4.68

25 7.18

25 8.2825 10.51 0.531 0.701 0.881 1.06

25 3.58

25 4.40

25 6.60

25 8.28

25 9.93

25 11.6

25 14.9

25 18.1

1 0.99

1 1.25

1 1.52

25 4.95

25 5.53

25 8.28

25 10.5

25 14.3

25 15.4

25 19.9

25 23.7

1 1.351 1.721 2.0725 5.5325 6.0825 8.28

25 11.0

25 13.2

25 21.5

1 1.081 1.521 1.961 2.38

1 0.84

25 5.80

25 16.5

5-16

9700 09700-2

9701 09701-9

9702 09702-6

9703 09703-3

9704 09704-0

9705 09705-7

9706 09706-4

9707 09707-1

9708 09708-8

9709 09709-5

9710 09710-1

9711 09711-8

9712 09712-5

9713 09713-2

9714 09714-9

9715 09715-6

9716 09716-3

9717 09717-09718 09718-79719 09719-49720 09720-09721 09721-79722 09722-4

9723 09723-1

9724 09724-8

9725 09725-5

9726 09726-2

9727 09727-9

9728 09728-6

9729 09729-3

9730 09730-9

9731 09731-6

9732 09732-3

9733 09733-0

9734 09734-7

9735 09735-4

9736 09736-1

9737 09737-8

9738 09738-5

9739 09739-2

9740 09740-8

9741 09741-5

9742 09742-29743 09743-99744 09744-69745 09745-39746 09746-09747 09747-7

9748 09748-4

9749 09749-1

9750 09750-7

9751 09751-4

9752 09752-19753 09753-89754 09754-59755 09755-2

1/2" Close 13/16"1/2" 1-1/2" 13/16"

1/2" 2" 13/16"1/2" 2-1/2" 13/16"

1/2" 3" 13/16"

1/2" 3-1/2" 13/16"

1/2" 4" 13/16"

1/2" 5" 13/16"

1/2" 6" 13/16"

1/2" 8" 13/16"

1/2" 10" 13/16"

1/2" 12" 13/16"

3/4" Close 1-1/16"

3/4" 2" 1-1/16"

3/4" 2-1/2" 1-1/16"

3/4" 3" 1-1/16"

3/4" 3-1/2" 1-1/16"

3/4" 4" 1-1/16"

3/4" 5" 1-1/16"3/4" 6" 1-1/16"3/4" 8" 1-1/16"

3/4" 10" 1-1/16"3/4" 12" 1-1/16"

1" Close 1-5/16"

1" 2" 1-5/16"

1" 2-1/2" 1-5/16"

1" 3" 1-5/16"

1" 3-1/2" 1-5/16"

1" 4" 1-5/16"

1" 5" 1-5/16"

1" 6" 1-5/16"

1" 8" 1-5/16"

1" 10" 1-5/16"

1" 12" 1-5/16"

1-1/4" Close 1-11/16"

1-1/4" 2" 1-11/16"

1-1/4" 2-1/2" 1-11/16"

1-1/4" 3" 1-11/16"

1-1/4" 3-1/2" 1-11/16"

1-1/4" 4" 1-11/16"

1-1/4" 5" 1-11/16"

1-1/4" 6" 1-11/16"

1-1/4" 8" 1-11/16"1-1/4" 10" 1-11/16"

1-1/4" 12" 1-11/16"

1-1/2" Close 1-7/8"1-1/2" 2" 1-7/8"1-1/2" 2-1/2" 1-7/8"

1-1/2" 3" 1-7/8"

1-1/2" 3-1/2" 1-7/8"1-1/2" 4" 1-7/8"

1-1/2" 5" 1-7/8"

1-1/2" 6" 1-7/8"

1-1/2" 8" 1-7/8"

1-1/2" 10" 1-7/8"1-1/2" 12" 1-7/8"

2" 6" 2-3/8"

2" 8" 2-3/8"

2" 10" 2-3/8"

2" 12" 2-3/8"

Page 54: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Rigid Threaded Nipples

RIGID CONDUIT Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions A B

Ctn/Case Case

Qty/Qty Wt.

Boxed 9756 09756-9 2" Close 2-3/8" 25 9.93 9757 09757-6 2" 2-1/2" 2-3/8" 25 10.3 9758 09758-3 2" 3" 2-3/8" 25 14.3 9759 09759-0 2" 3-1/2" 2-3/8" 25 17.7 9760 09760-6 2" 4" 2-3/8" 25 22.1 9761 09761-3 2" 5" 2-3/8" 25 28.7 9762 09762-0 2" 6" 2-3/8" 1 1.43 9763 09763-7 2" 8" 2-3/8" 1 2.03 9764 09764-4 2" 10" 2-3/8" 1 2.82 9765 09765-1 2" 12" 2-3/8" 1 3.26 9766 09766-8 2-1/2" Close 2-7/8" 1 0.61 9767 09767-5 2-1/2" 3" 2-7/8" 1 0.64 9768 09768-2 2-1/2" 3-1/2" 2-7/8" 1 0.88 9769 09769-9 2-1/2" 4" 2-7/8" 1 1.12 9770 09770-5 2-1/2" 5" 2-7/8" 1 1.57 9771 09771-2 2-1/2" 6" 2-7/8" 1 2.05 9772 09772-9 2-1/2" 8" 2-7/8" 1 2.98 9773 09773-6 2-1/2" 10" 2-7/8" 1 3.92 9774 09774-3 2-1/2" 12" 2-7/8" 1 4.87 9775 09775-0 3" Close 3-1/2" 1 0.77 9776 09776-7 3" 3" 3-1/2" 1 0.86 9777 09777-4 3" 3-1/2" 3-1/2" 1 1.15 9778 09778-1 3" 4" 3-1/2" 1 1.48 9779 09779-8 3" 5" 3-1/2" 1 2.05 9780 09780-4 3" 6" 3-1/2" 1 2.62 9781 09781-1 3" 8" 3-1/2" 1 3.79 9782 09782-8 3" 10" 3-1/2" 1 4.96 9783 09783-5 3" 12" 3-1/2" 1 5.75 9784 09784-2 3-1/2" Close 4" 1 0.88 9785 09785-9 3-1/2" 4" 4" 1 2.03 9786 09786-6 3-1/2" 5" 4" 1 2.49 9787 09787-3 3-1/2" 6" 4" 1 3.15 9788 09788-0 3-1/2" 8" 4" 1 4.50 9789 09789-7 3-1/2" 10" 4" 1 5.84 9790 09790-3 3-1/2" 12" 4" 1 7.19 9791 09791-0 4" Close 4-1/2" 1 1.15 9792 09792-7 4" 4" 4-1/2" 1 2.03 9793 09793-4 4" 5" 4-1/2" 1 2.80 9794 09794-1 4" 6" 4-1/2" 1 3.57 9795 09795-8 4" 8" 4-1/2" 1 5.18 9796 09796-5 4" 10" 4-1/2" 1 6.68 9797 09797-2 4" 12" 4-1/2" 1 8.25

Use: Threaded nipples are used to extend a length of threaded Rigid or IMC Conduit according to the pipe size and length desired. May also be used to connect two steel outlet boxes or metal enclosures together.

Materials • Zinc Plated Steel

TECICIICCI 1-L p Rci. L3L , c G Immom,

Teddico/BWF Pittsburgh, Pa. 15205

Use:Threaded nipples are used to extend a length of

threaded Rigid or IMC Conduit according to the

pipe size and length desired. May also be used to

connect two steel outlet boxes or metal enclosures

together.

Materials • Zinc Plated Steel

Rigid Threaded Nipples

RIGID CONDUIT

Boxed

Teddico/BWF Pittsburgh, Pa. 15205

RIG

ID C

ON

DU

IT

25 10.3

25 14.3

25 17.7

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Qty/Qty Wt.Number 0-87115 Size A B

25 22.1

25 28.7

1 1.43

1 2.03

1 2.82

1 3.26

1 0.61

1 0.64

1 0.88

1 1.12

1 1.57

1 2.98

1 3.92

1 4.87

1 0.86

1 1.151 1.481 2.051 2.621 3.791 4.96

1 5.75

1 0.88

1 2.03

1 2.49

1 3.15

1 4.50

1 5.84

1 7.19

1 1.15

1 2.03

1 2.80

1 3.57

1 5.18

1 8.25

1 6.68

1 0.77

1 2.05

5-17

9776 09776-7

9777 09777-49778 09778-19779 09779-89780 09780-49781 09781-19782 09782-8

9783 09783-5

9784 09784-2

9785 09785-9

9786 09786-6

9787 09787-3

9788 09788-0

9789 09789-7

9790 09790-3

9791 09791-0

9792 09792-7

9793 09793-4

9794 09794-1

9795 09795-8

9796 09796-5

9797 09797-2

9775 09775-0

4" 12" 4-1/2"

25 9.939756 09756-9 2" Close 2-3/8"9757 09757-6

9758 09758-3

9759 09759-09760 09760-6

9761 09761-3

9762 09762-0

9763 09763-7

9764 09764-4

9765 09765-1

9766 09766-8

9767 09767-5

9768 09768-2

9769 09769-9

9770 09770-5

9771 09771-2

9772 09772-9

9773 09773-6

9774 09774-3

2" 2-1/2" 2-3/8"2" 3" 2-3/8"

2" 3-1/2" 2-3/8"

2" 4" 2-3/8"

2" 5" 2-3/8"2" 6" 2-3/8"

2" 8" 2-3/8"

2" 10" 2-3/8"

2" 12" 2-3/8"2-1/2" Close 2-7/8"

2-1/2" 3" 2-7/8"

2-1/2" 3-1/2" 2-7/8"

2-1/2" 4" 2-7/8"

2-1/2" 5" 2-7/8"

2-1/2" 6" 2-7/8"

2-1/2" 8" 2-7/8"

2-1/2" 10" 2-7/8"

2-1/2" 12" 2-7/8"3" Close 3-1/2"

3" 3" 3-1/2"

3" 3-1/2" 3-1/2"

3" 4" 3-1/2"3" 5" 3-1/2"

3" 6" 3-1/2"3" 8" 3-1/2"3" 10" 3-1/2"3" 12" 3-1/2"

3-1/2" Close 4"3-1/2" 4" 4"

3-1/2" 5" 4"

3-1/2" 6" 4"

3-1/2" 8" 4"

3-1/2" 10" 4"

3-1/2" 12" 4"

4" Close 4-1/2"

4" 4" 4-1/2"

4" 5" 4-1/2"

4" 6" 4-1/2"

4" 8" 4-1/2"4" 10" 4-1/2"

Page 55: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

4N? 0

Use: Two hole straps are used for providing support for Rigid or IMC Conduit as required by the National Electrical Code where higher load bearing supports are desired. • Click-On Type

Materials • Stamped Steel

Finish • Zinc Plated Certification

E229278

Standards UL 2239 CSA C22.2 No. 18 NEC Article 345 & 346

Malleable Clamp Back

Rigid One Hole Straps

Use: One hole straps are used for providing support for Rigid or IMC Conduit as required by the National Electrical Code.

• Click-On Type

Materials • Stamped Steel

Finish • Zinc Plated

RIGID CONDUIT Catalog Number

UPC No

0-87115

Trade Size

Nominal Dimensions Pcs/ A B C Unit

Ctn/Case Case Qty/Qty Wt.

Boxed 9320 09320-2 1/2" 1.85 0.62 0.90 50/500 17.6 9321 09321-9 3/4" 2.20 0.75 1.13 50/500 29.2 9322 09322-6 1" 2.60 0.88 1.32 50/500 42.4 9323 09323-3 11/4" 2.95 0.88 1.64 25/250 29.6 9324 09324-0 1 1/2" 3.62 1.02 1.90 25/250 40.5 9325 09325-7 2" 4.09 1.14 2.32 25 6.3

*9316 09316-5 21/2" 4.90 1.25 3.00 25 11.7 *9317 09317-2 3" 5.53 1.25 3.60 25 12.7 *9318 09318-9 31/2" 6.18 1.25 4.13 25 14.2 *9319 09319-6 4" 6.68 1.25 4.63 25 15.7

*EMT & RIGID

_.. R

IGID

CO

ND

UIT

Rigid Two Hole Straps

RIGID CONDUIT Catalog Number

UPC No

0-87115

Trade Size

Nominal Dimensions A B C

Pcs/ Ctn/Case Case Unit Qty/Qty Wt.

Boxed 9340 09340-0 1/2" 2.48 0.62 0.87 50/500 11.8 9341 09341-7 3/4" 2.91 0.69 0.98 50/500 14.9 9342 09342-4 1" 3.36 0.75 1.30 25/250 13.2 9343 09343-1 1 1/4" 4.09 0.88 1.61 50 3.7 9344 09344-8 1 1/2" 4.40 0.94 1.90 50 5.3 9345 09345-5 2" 5.11 1 2.30 50 6.7

* 9336 09336-3 2 1/2" 5.88 1.00 2.91 25 5.1 * 9337 09337-0 3" 6.50 1.00 3.53 25 5.9 * 9338 09338-7 3 1/2" 7.38 1.00 4.03 25 8.3 * 9339 09339-4 4" 8.00 1.00 4.53 25 9.1

*EMT & RIGID

RIGID CONDUIT Catalog UPC No Trade

Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size

A B C Unit Qty/Qty Wt.

Boxed Use: 9500 09500 1/2" 4.80 1.95 0.96 25/250 24.1 Used to provide space between rigid conduit or IMC and 9501 09501 3/4" 5.42 2.50 0.78 25/250 26.2 mounting surface. Can be used with one hole straps. 9502 09502 1" 6.79 2.68 0.86 25/125 17.8 Cast of high strength malleable iron and zinc plated. 9503 09503 1 1/4" 7.32 2.89 1.06 20/100 21.7 Materials 9504 09504 1 1/2" 8.07 3.48 1.09 10/100 28.9 • Malleable Iron 9505 09505 2" 4.80 1.95 0.96 10/50 26.3 Finish 9506 09506 2 1/2" 5.42 2.50 0.78 10 6.5 • Zinc Plated 9507 09507 3" 6.79 2.68 0.86 10 10.7 Certification 9508 09508 3 1/2" 7.32 2.89 1.06 10 14.0

LR57925 9509 09509 4" 8.07 3.48 1.09 10 15.7

TECICIICCI 31,44 Teddico/BWF Pittsburgh, Pa. 15205

1,-4nG3tJc..IS ,InWr

Use:One hole straps are used for providing support for

Rigid or IMC Conduit as required by the National

Electrical Code.

• Click-On Type

Materials • Stamped Steel

Finish • Zinc Plated

Rigid One Hole Straps RIGID CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9320 09320-2 1/2" 1.85 0.62 0.90 - 50/500 17.6

9321 09321-9 3/4" 2.20 0.75 1.13 - 50/500 29.2

9322 09322-6 1" 2.60 0.88 1.32 - 50/500 42.4

9323 09323-3 1 1/4" 2.95 0.88 1.64 - 25/250 29.6

9324 09324-0 1 1/2" 3.62 1.02 1.90 - 25/250 40.5

9325 09325-7 2" 4.09 1.14 2.32 - 25 6.3

9316 09316-5 2 1/2" 4.90 1.25 3.00 - 25 11.7

9317 09317-2 3" 5.53 1.25 3.60 - 25 12.7

9318 09318-9 3 1/2" 6.18 1.25 4.13 - 25 14.2

9319 09319-6 4" 6.68 1.25 4.63 - 25 15.7

AC

B

Use:Two hole straps are used for providing support for

Rigid or IMC Conduit as required by the National

Electrical Code where higher load bearing

supports are desired.

• Click-On Type

Materials • Stamped Steel

Finish • Zinc Plated

CertificationE229278

Standards UL 2239

CSA C22.2 No. 18NEC Article 345 & 346

Rigid Two Hole Straps

RIGID CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed9340 09340-0 1/2" 2.48 0.62 0.87 - 50/500 11.8

9341 09341-7 3/4" 2.91 0.69 0.98 - 50/500 14.9

9342 09342-4 1" 3.36 0.75 1.30 - 25/250 13.2

9343 09343-1 1 1/4" 4.09 0.88 1.61 - 50 3.7

9344 09344-8 1 1/2" 4.40 0.94 1.90 - 50 5.3

9345 09345-5 2" 5.11 1 2.30 - 50 6.7

C

BA

Teddico/BWF Pittsburgh, Pa. 15205

RIG

ID C

ON

DU

IT

Malleable Clamp Back RIGID CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed

9505 09505 2" 4.80 1.95 0.96 - 10/50 26.3

9506 09506 2 1/2" 5.42 2.50 0.78 - 10 6.5

9507 09507 3" 6.79 2.68 0.86 - 10 10.7

9508 09508 3 1/2" 7.32 2.89 1.06 - 10 14.0

9509 09509 4" 8.07 3.48 1.09 - 10 15.7

A

C

B

Use:Used to provide space between rigid conduit or IMC and

mounting surface. Can be used with one hole straps.

Cast of high strength malleable iron and zinc plated.

Materials • Malleable Iron

Finish • Zinc Plated

Certification LR57925

9500 09500 1/2" 4.80 1.95 0.96 - 25/250 24.1

9501 09501 3/4" 5.42 2.50 0.78 - 25/250 26.2

9502 09502 1" 6.79 2.68 0.86 - 25/125 17.8

9503 09503 1 1/4" 7.32 2.89 1.06 - 20/100 21.7

9504 09504 1 1/2" 8.07 3.48 1.09 - 10/100 28.9

9336 09336-3 2 1/2" 5.88 1.00 2.91 - 25 5.1

9337 09337-0 3" 6.50 1.00 3.53 - 25 5.9

9338 09338-7 3 1/2" 7.38 1.00 4.03 - 25 8.3

9339 09339-4 4" 8.00 1.00 4.53 - 25 9.1

*EMT & RIGID

****

****

*EMT & RIGID

5-18

Page 56: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Rigid Conduit Hangers WI Nut & Bolt

(4/

Use: Conduit hangers are used to secure and suspend EMT, Rigid, IMC and PVC Conduits from overhead supports. • With Carriage Bolt and Nut Attached

Materials: • Stamped Steel

Finish: • Zinc Plated Certification:

E186443 LR104691

Rigid Conduit Hangers W/O Nut & Bolt

Use: Conduit hangers are used to secure and suspend EMT, Rigid, IMC and PVC Conduits from overhead supports. • Without Carriage Bolt and Nut Attached

Materials: • Stamped Steel

Finish: • Zinc Plated Certification:

E186443 LR104691

RIGID CONDUIT Catalog Number

UPC No

0-87115

Trade Size

Nominal Dimensions Pcs/ Ctn/Case Case Unit Qty/Qty Wt. A B C

Boxed 9450 09450-6 3/8", 1/2" 1.95 0.75 0.70 50/500 38.6 9451 09451-3 3/4" 2.21 0.75 0.82 100 8.3 9452 09452-0 1" 2.53 0.86 0.93 100 10.0 9453 09453-7 11/4" 2.72 0.86 0.98 100 12.2 9454 09454-4 1 1/2" 3.01 0.86 1.03 100 13.5 9455 09455-1 2" 3.31 0.96 1.10 100 18.9 9456 09456-8 21/2" 4.05 0.96 1.12 50 10.7 9457 09457-5 3" 4.60 1.18 1.25 25 7.5 9458 09458-2 31/2" 5.31 1.18 1.25 10 4.6 9459 09459-9 4" 5.31 1.18 1.25 10 4.6

RIGID CONDUIT Catalog Number

UPC No

0-87115

Trade Size

Nominal Dimensions Pcs/ Ctn/Case Case Unit Qty/Qty Wt. A B C

Boxed 9440 09440-7 3/8", 1/2" 1.95 0.75 0.70 50/500 38.6 9441 09441-4 3/4" 2.21 0.75 0.82 100 8.3 9442 09442-1 1" 2.53 0.86 0.93 100 10.0 9443 09443-8 1 1/4" 2.72 0.86 0.98 100 12.2 9444 09444-5 1 1/2" 3.01 0.86 1.03 100 13.5 9445 09445-2 2" 3.31 0.96 1.10 100 18.9 9446 09446-9 21/2" 4.05 0.96 1.12 50 10.7 9447 09447-6 3" 4.60 1.18 1.25 25 7.5 9448 09448-3 31/2" 5.31 1.18 1.25 10 4.6 9449 09449-0 4" 5.31 1.18 1.25 10 4.6

TEDDICD BWF 1,-if-113L117 .1S

www.teddicobwf.com Teddico/BWF Pittsburgh, Pa. 15205

Use:Conduit hangers are used to secure and suspend

EMT, Rigid, IMC and PVC Conduits from

overhead supports.

• With Carriage Bolt and Nut Attached

Materials:• Stamped Steel

Finish: • Zinc Plated

Certification:

Rigid Conduit Hangers

RIGID CONDUITCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed

AB

C

Use:Conduit hangers are used to secure and suspend

EMT, Rigid, IMC and PVC Conduits from

overhead supports.

• Without Carriage Bolt and Nut Attached

Materials:• Stamped Steel

Finish: • Zinc Plated

Certification:

Rigid Conduit HangersRIGID CONDUIT

Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed

9441 09441-4 3/4" 2.21 0.75 0.82 - 100 8.3

9442 09442-1 1" 2.53 0.86 0.93 - 100 10.0

9443 09443-8 1 1/4" 2.72 0.86 0.98 - 100 12.2

9444 09444-5 1 1/2" 3.01 0.86 1.03 - 100 13.5

9445 09445-2 2" 3.31 0.96 1.10 - 100 18.9

9446 09446-9 2 1/2" 4.05 0.96 1.12 - 50 10.7

9447 09447-6 3" 4.60 1.18 1.25 - 25 7.5

9448 09448-3 3 1/2" 5.31 1.18 1.25 - 10 4.6

AB

C

Teddico/BWF Pittsburgh, Pa. 15205

RIG

ID C

ON

DU

IT

W / Nut & Bolt

W /O Nut & Bolt

9449 09449-0 4" 5.31 1.18 1.25 - 10 4.6

E186443 LR104691

E186443 LR104691

5-19www.teddicobwf.com

9450 09450-6 3/8", 1/2" 1.95 0.75 0.70 - 50/500 38.6

9451 09451-3 3/4" 2.21 0.75 0.82 - 100 8.3

9452 09452-0 1" 2.53 0.86 0.93 - 100 10.0

9453 09453-7 1 1/4" 2.72 0.86 0.98 - 100 12.2

9454 09454-4 1 1/2" 3.01 0.86 1.03 - 100 13.5

9455 09455-1 2" 3.31 0.96 1.10 - 100 18.9

9456 09456-8 2 1/2" 4.05 0.96 1.12 - 50 10.7

9457 09457-5 3" 4.60 1.18 1.25 - 25 7.5

9458 09458-2 3 1/2" 5.31 1.18 1.25 - 10 4.6

9459 09459-9 4" 5.31 1.18 1.25 - 10 4.6

9440 09440-7 3/8", 1/2" 1.95 0.75 0.70 - 50/500 38.6

Page 57: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

. G

RO

UN

D F

ITT

ING

S

Ground clamp

Use: Ground clamps are used to connect bare or insulated copper wire to copper or galvanized steel water pipe. • For #8#2 AWG

Materials • Zinc Die-Cast

Finish • Natural or Brass Plated

Certification

01)

E88878® LR57925

Standards UL 467 CSA C22.2 No. 41 NEMA FB-1 NEC Article 250

Ground clamp

Use: Ground clamps are used to connect bare or insulated copper wire to copper or galvanized steel water pipe. • For #10#2 AWG

Materials • Bronze Certification

E88878 LR57925

Standards UL 467 CSA C22.2 No. 41 NEC Article 250

GROUND FITTINGS Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed 8212 08212-1 1/2"-1" 2.24 1.34 0.62

25/250 37.5

8212-BP* 08402-6 1/2"-1" 2.24 1.34 0.62

25/250 39.2

* Brass plated ground clamps are not UL fisted because plating is a material or color different from natural zinc.

GROUND FITTINGS Catalog Number

UPC No 0-87115

Trade Size

Nominal Dimensions Pcs/ A B C Unit

Ctn/Case Case

Qty/Qty Wt.

Boxed 8206 08206-0 1/2"-1" 2.28 1.48 0.64 25/125 24.1 8206-D* 08379-1 1/2"-1" 2.28 1.48 0.64 25/125 25.3 8207 08207-7 1 1/4"-2" 3.59 2.15 0.75 5/50 21.2 8207-D* 08407-1 1 1/4"-2" 3.59 2.15 0.75 5/50 21.8

* With Bronze Screws Suitable for Direct Burial.

-rsciclic CI ELECTRICAL PRODUCTS

Teddico/BWF Pittsburgh, Pa. 15205

Use:Ground clamps are used to connect bare or

insulated copper wire to copper or galvanized

steel water pipe.

• For #8#2 AWG

Materials• Zinc Die-Cast

Finish • Natural or Brass Plated

Certification E88878 LR57925

StandardsUL 467

CSA C22.2 No. 41

NEMA FB-1

NEC Article 250

Ground clamp GROUND FITTINGSCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8212 08212-1 1/2"-1" 2.24 1.34 0.62 - 25/250 37.5

8212-BP* 08402-6 1/2"-1" 2.24 1.34 0.62 - 25/250 39.2

A

B

C

Use:Ground clamps are used to connect bare or

insulated copper wire to copper or galvanized

steel water pipe.

• For #10#2 AWG

Materials • Bronze

Certification E88878 LR57925

Standards UL 467

CSA C22.2 No. 41

NEC Article 250

Ground clamp GROUND FITTINGSCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8206 08206-0 1/2"-1" 2.28 1.48 0.64 - 25/125 24.1

8206-D* 08379-1 1/2"-1" 2.28 1.48 0.64 - 25/125 25.3

8207 08207-7 1 1/4"-2" 3.59 2.15 0.75 - 5/50 21.2A

B

C

* Brass plated ground clamps are notUL listed because plating is a materialor color different from natural zinc.

* With Bronze ScrewsSuitable for Direct Burial.

Teddico/BWF Pittsburgh, Pa. 15205

GR

OU

ND

FIT

TIN

GS

6-1

8207-D* 08407-1 1 1/4"-2" 3.59 2.15 0.75 - 5/50 21.8

Page 58: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Ground clamp

GROUND FITTINGS Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed 8209 08209-1 1/2"-1" 2.25 1.34 0.99

10/100 21.9

*With Bronze Screw Suitable for Direct Burial

Use: Ground clamps are used to connect Armored Cable to copper or galvanized steel water pipe. Pressure bar grips Armored cable insulation to decrease chances of grounding conductor being pulled out.

• For #8-#4 AWG

Materials • Bronze Certification

E88878•LR57925

Standards UL 467 CSA C22.2 No. 41 NEC Article 250

Ground clamp

GROUND FITTINGS Catalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed L-163B 73220-0 1/2"-1" 2.24 1.5 0.62

25/250 56.1

Use: Used to connect bare copper wire to water pipe, ground rod or copper water tubing for grounding

• For #8 - #2 AWG

Materials • Brass colored zinc plated

TECICHICCD B F Teddico/BWF Pittsburgh, Pa. 15205

ELECTRICAL PRODUCTS 'IMMUrm,

Use:Ground clamps are used to connect Armored

Cable to copper or galvanized steel water pipe.

Pressure bar grips Armored cable insulation to

decrease chances of grounding conductor being

pulled out.

• For #8-#4 AWG

Materials • Bronze

Certification E88878 LR57925

Standards UL 467

CSA C22.2 No. 41

NEC Article 250

Ground clamp GROUND FITTINGSCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

Boxed8209 08209-1 1/2"-1" 2.25 1.34 0.99 - 10/100 21.9

A

B

C

Use:Used to connect bare copper wire to water pipe,

ground rod or copper water tubing for grounding

• For #8 - #2 AWG

Materials • Brass colored zinc plated

Ground clamp GROUND FITTINGSCatalog UPC No Trade Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 Size A B C Unit Qty/Qty Wt.

BoxedL-163B 73220-0 1/2"-1" 2.24 1.5 0.62 - 25/250 56.1

A

B

C

*With Bronze ScrewSuitable for Direct Burial

Teddico/BWF Pittsburgh, Pa. 15205

GR

OU

ND

FITT

ING

S

6-2

Page 59: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Ground clamp with Hub

GR

OU

ND

FIT

TIN

GS

.

GROUND FITTINGS Catalog UPC No Trade Nominal Dimensions Hub Ctn/Case Case Number 0-87115 Size A B C Size Qty/Qty Wt.

Boxed 8213 08213-8 1/2"-1" 2.25 1.25 2.04 1/2" 25/125 35.8 8214 08214-5 1 1/4"-2" 2.25 1.25 2.04 1/2" 5/50 35.0

GROUND FITTINGS Catalog Number

UPC No

0-87115

Trade Size

Nominal Dimensions A B C

Hub Size

Ctn/Case Case Qty/Qty Wt.

Boxed 8206-05 08374-6 1/2"-1" 6.08 1.06 2.35 1/2" 10 4.3 8206-C7 08378-4 1/2"-1" 6.08 1.27 2.55 3/4" 10 5.3 8206-C1 08373-9 1/2"-1" 6.08 1.06 2.35 1" 10 6.3

GROUND FITTINGS Catalog UPC No Trade Nominal Dimensions Ctn/Case Case Number 0-87115 Size A B C Qty/Qty Wt.

Boxed 8465 08465-1 1/2" 0.76 0.65 1.20 25/250 23.5 8466 08466-8 5/8" 0.90 0.61 1.34 25/250 25.4 8467 08467-5 3/4" 1.08 0.70 1.50 25/250 27.3

Use: Ground clamps with hub are used to connect a ground wire in Rigid Conduit to copper or galvanized steel water pipe.

• 1/2" Threaded Hub Mounts to Rigid Conduit Materials • Bronze

Certification

11::) E88878 LR57925

Standards UL 467 CSA C22.2 No. 41 NEC Article 250

Ground clamp with Strap

Use: Ground clamps with hub are used to connect a ground wire in Rigid Conduit to copper or galvanized steel water pipe.

• 7" Copper Strap Protects Conduit System from the Effects of Vibrations in Water System

• 1/2" Threaded Hub Mounts to Rigid Conduit

Materials • Bronze Clamp and Hub • Copper Strap Certification

E88878•LR57925

Standards UL 467 CSA C22.2 No. 41 NEC Article 25

Ground Rod Clamps for Direct Burial

Use: Ground rod clamps are used to connect bare copper conductors directly to a driven ground rod. • For 10 Sol - 2 Str

• Suitable for Direct Burial in Ground and Concrete Materials • Bronze

C

E88878 LR57925

Standards UL 467 CSA C22.2 No. 41 NEC Article 250

TEDDICD BWE Teddico/BWF Pittsburgh, Pa. 15205

HirrkL

Use:Ground clamps with hub are used to connect a

ground wire in Rigid Conduit to copper or

galvanized steel water pipe.

• ½" Threaded Hub Mounts to Rigid Conduit

Materials • Bronze

Certification E88878 LR57925

Standards UL 467 CSA C22.2 No. 41

NEC Article 250

Ground clamp with Hub GROUND FITTINGSCatalog UPC No Trade Nominal Dimensions Hub Ctn/Case Case

Number 0-87115 Size A B C Size Qty/Qty Wt.

Boxed8213 08213-8 1/2"-1" 2.25 1.25 2.04 1/2" 25/125 35.8

A

C

B

Use:Ground clamps with hub are used to connect a

ground wire in Rigid Conduit to copper or galvanized

steel water pipe.

• 7" Copper Strap Protects Conduit System from the

Effects of Vibrations in Water System

• ½" Threaded Hub Mounts to Rigid Conduit

Materials • Bronze Clamp and Hub

• Copper Strap

Certification E88878 LR57925

StandardsUL 467 CSA C22.2 No. 41NEC Article 25

Ground clamp with StrapGROUND FITTINGS

Catalog UPC No Trade Nominal Dimensions Hub Ctn/Case Case

Number 0-87115 Size A B C Size Qty/Qty Wt.

Boxed

A

C

B

Teddico/BWF Pittsburgh, Pa. 15205

Use:Ground rod clamps are used to connect bare

copper conductors directly to a driven ground rod.

• For 10 Sol - 2 Str

• Suitable for Direct Burial in Ground and

Concrete

Materials • Bronze

Certification E88878 LR57925

Standards UL 467

CSA C22.2 No. 41

NEC Article 250

Ground Rod Clamps GROUND FITTINGS

Boxed

C

B

A

GR

OU

ND

FIT

TIN

GS

8206-C5 08374-6 1/2"-1" 6.08 1.06 2.35 1/2" 10 4.3

8206-C7 08378-4 1/2"-1" 6.08 1.27 2.55 3/4" 10 5.3

8206-C1 08373-9 1/2"-1" 6.08 1.06 2.35 1" 10 6.3

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

25/250 23.5

25/250 25.4

25/250 27.3

8465 08465-1 1/2" 0.76 0.65 1.20

8466 08466-8 5/8" 0.90 0.61 1.34

8467 08467-5 3/4" 1.08 0.70 1.50

for Direct Burial

6-3

8214 08214-5 1 1/4"-2" 2.25 1.25 2.04 1/2" 5/50 35.0

Page 60: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

Beam Clamp ACCESSORIES Catalog UPC No Hole Jaw Ctn/Case Case Number 0-31857 Size Opening Qty/Qty Wt.

Boxed

Use: Beam clamps are used on a beam, girder or other similar structure to provide a mounting base for conduit hangers.

Materials • Malleable Iron

Finish • Zinc Plated

Certification ® E229278

10 7.75 10 12.81 100 22.41

9361 09361-5 3/8"- 16 0.88 9362 09362-2 1/2"- 13 1.19 9363 09363-9 1/4"- 20 0.81

ACCESSORIES Catalog UPC No Hole Jaw Ctn/Case Case Number 0-31857 Size Opening Qty/Qty Wt.

Boxed 9360 09360-8 1/4"- 20 11/16" 100 14.0

Materials • Steel

Knock-Out Seals ACCESSORIES Catalog UPC No Trade Nominal Dimensions Ctn/Case Case Number 0-31857 Size A B Qty/Qty Wt.

Boxed

A

100/1000 10.0

100/1000 20.0

50/500 9.0

50/500 10.0

50/500 20.6

10/100 5.0

9270 09270-0 1/2" 1.00 0.37 9271 09271-7 3/4" 1.17 0.40

9272 09272-4 1" 1.45 0.44

9273 09273-1 1-1/4" 1.85 0.40

9274 09274-8 1-1/2" 2.20 0.31

9275 09275-5 2" 2.64 0.38 Knock-out seals are used to close exposed holes in an outlet box or metal enclosure.

Materials • Steel

B '111 F ELECTRICAL PRODUCTS 'IMMUrm,

Teddico/BWF Pittsburgh, Pa. 15205

Use:Beam clamps are used on a beam, girder or

other similar structure to provide a mounting

base for conduit hangers.

Materials • Malleable Iron

Finish • Zinc Plated

Certification E229278

Beam Clamp ACCESSORIES

Boxed9361 09361-5 3/8"- 16 0.88 10 7.75

Use:Knock-out seals are used to close exposed

holes in an outlet box or metal enclosure.

Materials • Steel

Knock-Out Seals

A

B

ACCESSORIES

Boxed

Teddico/BWF Pittsburgh, Pa. 15205

AC

CE

SS

OR

IES

Catalog UPC No Hole Jaw Ctn/Case Case

Number 0-31857 Size Opening Qty/Qty Wt.

Ctn/Case CaseQty/Qty Wt.

100/1000 10.0

100/1000 20.0

50/500 9.0

50/500 10.0

50/500 20.6

10/100 5.0

Catalog UPC No Trade Nominal DimensionsNumber 0-31857 Size A B

9270 09270-0 1/2" 1.00 0.37

9271 09271-7 3/4" 1.17 0.40

9272 09272-4 1" 1.45 0.44

9273 09273-1 1-1/4" 1.85 0.40

9274 09274-8 1-1/2" 2.20 0.31

9275 09275-5 2" 2.64 0.38

7-1

9362 09362-2 1/2"- 13 1.19 10 12.81

9363 09363-9 1/4"- 20 0.81 100 22.41

Materials • Steel

ACCESSORIES

Boxed9360 09360-8 1/4"- 20 11/16" 100 14.0

Catalog UPC No Hole Jaw Ctn/Case Case

Number 0-31857 Size Opening Qty/Qty Wt.

Page 61: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

ACCESSORIES

Box spacers are used for providing a raceway between two steel outlet boxes or metal enclosures by connecting either side by side or back to back.

Materials • Zinc Die-Cast Certification

® E155411•LR57925

Switch Box Supports

Use: Switch box supports are used to attach an outlet box in drywall where there are no means of attaching the box to a structure.

Materials • Steel

Protector Plate w/ Prongs

Use: Safety plates are used to protect cable insulation from nail punctures in wooden structures.

Materials • Steel

Standards NEC Article 300-4

Ground Clip

Use: Ground clips are used to attach a ground wire to the side wall of a switch or outlet box.

Materials • Steel

*Sold in Pairs

ACCESSORIES

Boxed 9262 09262-5 21/2" 2.5 1.5 0.062 200 12.0 9263 09263-2 5" 5.0 1.5 0.062 100 12.0

Boxed 9261 09261-8 0.67 0.40 0.32 100 10/100 1.4

Teddico/BWF Pittsburgh, Pa. 15205

N, , A

CC

ES

SO

RIE

S

.

-rsciclic CI litik_r ELECTRICAL PRODUCTS -.I-

Box Spacers RIGID CONDUIT

Boxed 8202 08202-2 1/2" 1.12 0.40 0.62 50/500 38.6

ACCESSORIES

Finish • Green

5 1/8" 100 2.7 2 1/4" boxed *9260 09260-1

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case Number 0-87115 Size A B C Qty/Qty Wt.

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case Number 0-87115 Size A B C Qty/Qty Wt.

Catalog UPC No Nominal Dimensions Pcs/ Ctn/Case Case Number 0-87115 A B C Unit Qty/Qty Wt.

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case Number 0-87115 Size A B Qty/Qty Wt.

tar. Use:Switch box supports are used to attach an outlet

box in drywall where there are no means of

attaching the box to a structure.

Materials • Steel

Switch Box Supports ACCESSORIES

boxed

A

B

Teddico/BWF Pittsburgh, Pa. 15205

AC

CE

SS

OR

IES

Number 0-87115 Size A B Qty/Qty Wt.

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

*9260 09260-1 - 5 1/8" 2 1/4" 100 2.7

Use:Safety plates are used to protect cable

insulation from nail punctures in wooden

structures.

Materials • Steel

Standards NEC Article 300-4

Protector Plate w/ Prongs

A

B

C

ACCESSORIES

Boxed

Use:Ground clips are used to attach a ground wire to

the side wall of a switch or outlet box.

Materials• Steel

Finish • Green

Ground Clip ACCESSORIES

BoxedA

B

C

9263 09263-2 5" 5.0 1.5 0.062 100 12.0

9262 09262-5 2 1/2" 2.5 1.5 0.062 200 12.0

Number 0-87115 Size A B C Qty/Qty Wt.

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

7-2

Use:Box spacers are used for providing a raceway

between two steel outlet boxes or metal

enclosures by connecting either side by side or

back to back.

Materials • Zinc Die-Cast

Certification E155411 LR57925

Box SpacersRIGID CONDUIT

BoxedB

A

C

Catalog UPC No Trade Nominal Dimensions Ctn/Case Case

Number 0-87115 Size A B C Qty/Qty Wt.

8202 08202-2 1/2" 1.12 0.40 0.62 50/500 38.6

*Sold in Pairs

Catalog UPC No Nominal Dimensions Pcs/ Ctn/Case Case

Number 0-87115 A B C Unit Qty/Qty Wt.

9261 09261-8 0.67 0.40 0.32 100 10/100 1.4

Page 62: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

ACCESSORIES Fish Tapes

Nylon Fish Tape

Steel Fish Tape

Catalog Number

UPC No 0-87115

Description Ctn/Case Case Qty/Qty Wt.

Boxed NYLON 7600 07600-7 100ft Nylon Tape 8 16.0 7601 07601-4 150ft Nylon Tape 8 32.0

STEEL 7602 07602-1 50ft 1/ 81 Steel Tape 12 24.0 7603 07603-8 120ft 1/81 Steel Tape 8 40.0 7604 07604-5 200ft 1/81 Steel Tape 5 35.0

STAINLESS STEEL 7605 07605-0 200ft 1/81 Stainless Steel Tape 5 35.0

ACCESSORY 7606 07606-9 Malleable Iron tip for Nylon Fish Tape 200 11.1

Stainless Steel Fish Tape

Use: • High Impact, One-Piece Nylon Handle

for Durability & Ease of use • Curl Resistant Nylon or Steel 1/8" Fish

Tape for Both Large & Small Conduits • Fish Tape View Points Allow You to See

How Much Tape is Remaining on the Reel

• Nylon Tapes Have an Eyelet; Steel & Stainless Steel Tapes Have a Formed Hook

TEDDICD BWF Teddico/BWF Pittsburgh, Pa. 15205

ELECTRICAL ARCIDUCT ..9

Use:

Fish TapesACCESSORIES

Boxed

Teddico/BWF Pittsburgh, Pa. 15205

AC

CE

SS

OR

IES

Steel Fish Tape

Nylon Fish Tape

Stainless Steel Fish Tape

NYLON

7600 07600-7 100ft Nylon Tape 8 16.0

7601 07601-4 150ft Nylon Tape 8 32.0

STEEL

STAINLESS STEEL

7602 07602-1 50ft 1/ 8� Steel Tape 12 24.0

7603 07603-8 120ft 1/ 8� Steel Tape 8 40.0

7604 07604-5 200ft 1/ 8� Steel Tape 5 35.0

7605 07605-0 200ft 1/ 8� Stainless Steel Tape 5 35.0

• High Impact, One-Piece Nylon Handle

for Durability & Ease of use

• Curl Resistant Nylon or Steel 1/8" Fish

Tape for Both Large & Small Conduits

• Fish Tape View Points Allow You to See

How Much Tape is Remaining on the

Reel

• Nylon Tapes Have an Eyelet; Steel &

Stainless Steel Tapes Have a Formed

Hook

Catalog UPC No Description Ctn/Case Case

Number 0-87115 Qty/Qty Wt.

ACCESSORY7606 07606-9 Malleable Iron tip for Nylon Fish Tape 200 11.1

7-3

Page 63: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

NOTES NOTES

Page 64: CATALOG ATALOG FITTINGS & ACCESSORIES GS & ACCESSORIES

TEDDICO = ELECTRICAL PRODUCTS

1.1

A Leading Manufacturer of Electrical Fittings Products

1104 Parkway View Drive, Bldg 11 • Pittsburgh, PA 15205 • Phone: 412-747-4970 • Fax: 412-747-4973 • www.teddico.com

A Leading Manufacturer of Electrical Fittings Products

1104 Parkway View Drive, Bldg 11 • Pittsburgh, PA 15205 • Phone: 412-747-4970 • Fax: 412-747-4973 • www.teddico.com