bus links pn/pn coupler - siemens ag · bus links pn/pn coupler installation and operating manual...

78
SIMATIC Bus links PN/PN coupler _ _____________ _ _____________ _ _____________ _ _____________ _ _____________ _ _____________ _ _____________ _ _____________ _ _____________ Preface Description 1 Assembling 2 Connecting 3 Configuring and commissioning 4 Operating 5 Diagnostics 6 Technical data A Order numbers and accessories B Dimensional drawings C SIMATIC Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation: No. Product Information Drawing number Edition 1 Supplement to the PN/PN Coupler Installation and Operating Manual A5E01102629-01 03/2007

Upload: lydang

Post on 18-Aug-2018

248 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

SIMATIC Bus links PN/PN coupler

______________________________________________________________________________________________________________________________

Preface

Description 1

Assembling 2

Connecting 3

Configuring and commissioning

4

Operating 5

Diagnostics 6

Technical data A

Order numbers and accessories

B

Dimensional drawings C

SIMATIC

Bus links PN/PN coupler

Installation and Operating manual

08/2006 A5E00717043-02

The following supplement is part of this documentation:

No. Product Information Drawing number Edition

1 Supplement to the PN/PN Coupler Installation and Operating Manual

A5E01102629-01

03/2007

Page 2: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.

Danger

indicates that death or severe personal injury will result if proper precautions are not taken.

Warning

indicates that death or severe personal injury may result if proper precautions are not taken.

Caution

with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.

Caution

without a safety alert symbol, indicates that property damage can result if proper precautions are not taken.

Notice

indicates that an unintended result or situation can occur if the corresponding information is not taken into account.

If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.

Qualified Personnel The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards.

Prescribed Usage Note the following:

Warning

This device may only be used for the applications described in the catalog or the technical description and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage, positioning and assembly as well as careful operation and maintenance.

Trademarks All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.

Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.

Siemens AG Automation and Drives Postfach 48 48 90437 NÜRNBERG GERMANY

Order No.: A5E00717043-02 Edition08/2006

Copyright © Siemens AG 2006. Technical data subject to change

Page 3: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 iii

Preface

Purpose of manual This manual provides you with all the information you need to configure, assemble, wire and commission the PN/PN coupler.

Basic knowledge required The following knowledge is required in order to understand the manual: ● general knowledge in the area of automation technology ● You will also need to know how to use computers or PC-like equipment (such as

programming devices) under Windows operating systems. ● Knowledge of working with STEP 7. This is gained from the Programming with

STEP 7 V5.4 manual.

Scope of manual The manual applies to PN/PN couplers with order numbers 6ES7158-3AD00-0XA0. This manual contains a description of the components which were valid at the time the manual was published. We reserve the right to include product information with information updates for new components and components with a new product status.

Changes compared to the previous version This is the first version of this manual.

Approvals See appendix "General technical data"

CE mark See appendix "General technical data"

Identification for Australia (C-Tick mark) See appendix "General technical data"

Page 4: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Preface

PN/PN coupler iv Installation and Operating manual, 08/2006, A5E00717043-01

Standards See appendix "General technical data"

Classification in information landscape Depending on the hardware used, you will need the following manuals in addition to this one: ● the manual for the IO controller used. The following details in this manual apply in

particular: – Configuring and commissioning of a PROFINET IO system – Description of the IO controller

● the PROFINET System Overview manual ● the Programming Manual From PROFIBUS DP to PROFINET IO

Guide The manual is based on the following subject areas: ● Product overview and description of the PN/PN coupler ● Assembly, wiring and commissioning ● Operation and diagnostics ● Appendices Important terms are explained in the glossary. The index helps you to quickly find all texts relevant to your keyword.

Recycling and disposal Given its environmentally-compatible equipment, the PN/PN coupler can be recycled. Contact a company certified in the disposal of electronic waste to ensure the environmentally-compatible recycling and disposal of your used device.

Contacts See product informationTechnical Support, Contacts and Training. You will find the product information on the Internet at: http://www.siemens.com/automation/service Search for the article numbered 19293011.

Page 5: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Preface

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 v

Training See product informationTechnical Support, Contacts and Training.

A&D Technical Support See product information Technical Support, Contacts and Training.

Service & Support on the Internet See product informationTechnical Support, Contacts and Training.

Page 6: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Preface

PN/PN coupler vi Installation and Operating manual, 08/2006, A5E00717043-01

Page 7: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 vii

Table of contents Preface. ..................................................................................................................................................... iii 1 Description.............................................................................................................................................. 1-1

1.1 Application and function............................................................................................................. 1-1 1.2 View ........................................................................................................................................... 1-3 1.3 Properties................................................................................................................................... 1-4

2 Assembling ............................................................................................................................................. 2-1 2.1 Assembly rules........................................................................................................................... 2-1 2.2 Assembling the PN/PN coupler.................................................................................................. 2-1 2.3 Disassembling the PN/PN coupler............................................................................................. 2-2 2.4 Assembling-color plates............................................................................................................. 2-2

3 Connecting ............................................................................................................................................. 3-1 3.1 Electrical isolation and grounding .............................................................................................. 3-1 3.1.1 Introduction ................................................................................................................................ 3-1 3.1.2 General operating rules and regulations.................................................................................... 3-2 3.2 Connections ............................................................................................................................... 3-3 3.3 Connecting the power supply..................................................................................................... 3-4 3.4 Connecting PROFINET IO......................................................................................................... 3-5

4 Configuring and commissioning.............................................................................................................. 4-1 4.1 Configuring and commissioning of the PN/PN coupler (overview) ............................................ 4-1 4.2 Configuring the PN/PN coupler with STEP 7............................................................................. 4-2 4.2.1 Requirements............................................................................................................................. 4-2 4.2.2 Configuring the PN/PN coupler with STEP 7............................................................................. 4-2 4.2.3 Example: Configuration of the inputs/outputs of the PN/PN coupler with STEP 7 .................... 4-5 4.3 Configuration of the PN/PN coupler with another configuring tool ............................................ 4-7 4.4 Parameters................................................................................................................................. 4-8 4.5 SNMP......................................................................................................................................... 4-9 4.6 Commissioning the PN/PN coupler ......................................................................................... 4-10

5 Operating................................................................................................................................................ 5-1 5.1 Response times of the PN/PN coupler ...................................................................................... 5-1 5.2 SIMATIC Micro Memory Card.................................................................................................... 5-2 5.3 Updating firmware...................................................................................................................... 5-3 5.3.1 Updating firmware using SIMATIC Micro Memory Card............................................................ 5-3 5.4 Replacing defective PN/PN coupler........................................................................................... 5-4 5.5 Identification data....................................................................................................................... 5-5

Page 8: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Table of contents

PN/PN coupler viii Installation and Operating manual, 08/2006, A5E00717043-01

6 Diagnostics ............................................................................................................................................. 6-1 6.1 Diagnostics via LED displays..................................................................................................... 6-1 6.2 Diagnostics by user program ..................................................................................................... 6-4 6.2.1 Manufacturer-specific diagnostics.............................................................................................. 6-4 6.2.2 Interrupts .................................................................................................................................... 6-4 6.2.3 Diagnostics readout ................................................................................................................... 6-5 6.2.4 Example of diagnostics .............................................................................................................. 6-6 6.2.5 Data validity display ................................................................................................................. 6-12 6.2.6 Evaluation of the user data flag ............................................................................................... 6-12 6.2.7 STOP of the IO controller and recovery of the IO device ........................................................ 6-12

A Technical data ........................................................................................................................................A-1 A.1 Technical data for PN/PN coupler (6ES7158-3AD00-0XA0) .....................................................A-1 A.2 General technical data ...............................................................................................................A-2 A.2.1 Introduction ................................................................................................................................A-2 A.2.2 Standards and approvals ...........................................................................................................A-3 A.2.3 Electromagnetic compatibility ....................................................................................................A-5 A.2.4 Transport and storage conditions ..............................................................................................A-7 A.2.5 Mechanical and climatic ambient conditions for operation ........................................................A-7 A.2.6 Specifications for insulation tests, safety class and degree of protection..................................A-9 A.2.7 Rated voltage ...........................................................................................................................A-10

B Order numbers and accessories.............................................................................................................B-1 B.1 Order numbers and accessories................................................................................................B-1

C Dimensional drawings.............................................................................................................................C-1 C.1 PN/PN coupler dimensional drawing .........................................................................................C-1

Glossary ..................................................................................................................................... Glossary-1 Index................................................................................................................................................ Index-1

Page 9: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Table of contents

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 ix

Tables

Table 4-1 Procedure for PN/PN coupler configuration and commissioning............................................... 4-1 Table 4-2 Parameters for the PN/PN coupler ............................................................................................ 4-8 Table 5-1 Basic structure of data records which contain ID data. ............................................................. 5-5 Table 5-2 Identification data....................................................................................................................... 5-6 Table 6-1 Status and error displays on the PN/PN coupler ....................................................................... 6-2 Table 6-2 Reading out the diagnostic data with STEP 7 ........................................................................... 6-5 Table 6-3 STL code for reading out diagnostics ........................................................................................ 6-7 Table 6-4 STL code for reading out diagnostic interrupts .......................................................................... 6-9 Table A-1 Pulse-shaped interferences .......................................................................................................A-5 Table A-2 Sinusoidal interferences.............................................................................................................A-6 Table A-3 Transport and storage conditions ..............................................................................................A-7 Table A-4 Mechanical ambient conditions..................................................................................................A-8 Table A-5 Tests for mechanical ambient conditions...................................................................................A-8 Table A-6 Climatic ambient conditions .......................................................................................................A-9 Table A-7 Test voltages..............................................................................................................................A-9 Table B-1 Order numbers for the PN/PN coupler.......................................................................................B-1

Page 10: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Table of contents

PN/PN coupler x Installation and Operating manual, 08/2006, A5E00717043-01

Page 11: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 1-1

Description 11.1 Application and function

Application and principle of operation The PN/PN coupler is used to link two Ethernet subnets with one another and to exchange data. The maximum size of the data which can be transferred is 256-byte input data and 256-byte output data. As one single device, the PN/PN coupler has two PROFINET interfaces, each of which is linked to another subnet. During configuring, two IO devices are produced from this one PN/PN coupler which means that there is one IO device for each station with its own subnet. The other part of PN/PN coupler in each case is known as the peer subnet. Once configuring is complete, the two parts are joined. You will need a SIMATIC Micro Memory Card to operate the PN/PN coupler.

Figure 1-1 Coupling two PROFINET subnets with one PN/PN coupler

Configuring You either configure the PN/PN coupler using STEP 7 or a configuring tool which uses a GSD file to integrate the PN/PN coupler. You can use STEP 7 to set the length of input and output data required. The output data of one side of the PN/PN coupler is transferred as the input data of the other side and vice versa. You configure the I/O ranges using universal modules which are plugged into slots on the PN/PN coupler like real modules from the hardware catalog in HW-Config. The universal modules span an I/O range over which data is exchanged between the two PROFINET subnets. The local CPU uses a slot's configured inputs to read the values which the CPU of the other subnet writes using the peer subnet's configured outputs. The local CPU uses a slot's configured outputs to write values which the CPU of the other subnet receives using the peer subnet's configured inputs.

Page 12: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Description 1.1 Application and function

PN/PN coupler 1-2 Installation and Operating manual, 08/2006, A5E00717043-01

Example The following example shows that both networks are independent of one another. In other words, you assign a unique device name for each PROFINET IO network. In the following picture, you can see device name "Subnet1" in network 1 and "Subnet2" in network 2.

Figure 1-2 Principle of operation of the PN/PN coupler (example)

Page 13: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Description 1.2 View

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 1-3

1.2 View

View The following picture shows the PN/PN coupler and its display elements:

Figure 1-3 Display elements and interfaces of the PN/PN coupler

① PROFINET IO interfaces for subnet 1 (X1) ⑥ Status LEDs for PROFINET IO subnet 1 (X1) ② PROFINET IO interfaces for subnet 2 (X2) ⑦ Status LEDs for PROFINET IO subnet 2 (X2) ③ Connection of power supply 1 with status LED ⑧ MAC address for PROFINET IO subnet 1 (X1) ④ Connection of power supply 2 with status LED ⑨ MAC address for PROFINET IO subnet 2 (X2) ⑤ Diagnostics LEDs for PROFINET IO subnet 1 and 2 (X1, X2) ⑩ Slot for SIMATIC Micro Memory Card

Page 14: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Description 1.3 Properties

PN/PN coupler 1-4 Installation and Operating manual, 08/2006, A5E00717043-01

1.3 Properties

Properties The PN/PN coupler has the following features: ● Maximum data exchange of 256-bytes input data and 256-byte output data ● Maximum of 16 input/output ranges for the exchange of data ● Electrical isolation between the two PROFINET IO subnets ● Redundant power supply ● Supported Ethernet services

– ping – arp – Net diagnostics (SNMP) / MIB-2

● Diagnostic interrupts ● ReturnOfSubmodule interrupts

Page 15: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 2-1

Assembling 22.1 Assembly rules

Mounting position You can mount the PN/PN coupler in any position. Please note that the maximum ambient temperature for horizontal mounting positions is 60 °C while that for all other positions is 40 °C. You will find more information on operating conditions in the appendix.

Open component The PN/PN coupler is an open component. In other words, you may only set it up in enclosures, cabinets or electrical service rooms. These should only be accessible by means of a key or a special tool. Only trained or authorized personnel may have access to the enclosures, cabinets or electrical service rooms.

Technical setup Mount the PN/PN coupler on a DIN rail (7.5 mm and 15 mm). Ensure a space of 40 mm both above and below the module for unimpeded assembly.

See also Mechanical and climatic ambient conditions for operation (Page A-7)

2.2 Assembling the PN/PN coupler

Components required ● PN/PN coupler ● Mounting rail:

– DIN rail (7.5 mm) or – DIN rail (15 mm)

You will find the order numbers for the components in the appendix "Order numbers and accessories".

Page 16: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Assembling 2.3 Disassembling the PN/PN coupler

PN/PN coupler 2-2 Installation and Operating manual, 08/2006, A5E00717043-01

Assembling PN/PN coupler on DIN rail 1. Assemble the DIN rail such that there is enough space for assembly and heat dissipation

of the modules (at least 40 mm above and below the modules). If you want to insert / replace the SIMATIC Micro Memory Card once the PN/PN coupler is assembled, you will have to leave additional space for this.

2. Fit the PN/PN coupler in the DIN rail and swing it down. 3. Wire the PN/PN coupler as described in the chapter "Connecting".

Note

If the assembly base is a grounded metal plate or a grounded equipment mounting plate, then you must ensure a low-ohm connection between the DIN rail and base. E.g. with painted or anodized metals, use a suitable contacting agent or contact washers.

See also Order numbers and accessories (Page B-1)

2.3 Disassembling the PN/PN coupler

Disassembling the PN/PN coupler 1. Switch off the PN/PN coupler's power supply. 2. Loosen the wiring and bus connector from the PN/PN coupler. 3. Use a screwdriver to push down the slide valve on the underneath of the PN/PN coupler. 4. With the slide valve still pressed down, swing the PN/PN coupler out of the mounting rail.

2.4 Assembling-color plates

Introduction The color-coding plates allow you to individually color code the PROFINET IO interfaces in accordance with company and national regulations. The color-coding plates are available in white, red, yellow, yellow-green, brown, blue and turquoise. You can provide every PROFINET IO interface on the PN/PN coupler with a color-coding plate. The color-coding plates are positioned on the bottom right of each PROFINET IO interface.

Required tool Screwdriver 3.5 mm blade width

Page 17: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Assembling 2.4 Assembling-color plates

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 2-3

Assembling color-coding plates 1. Use the screwdriver to push the spigot of the color-coding plate into the opening provided

for this in the PN/PN coupler. 2. Secure the color-coding plate as described below. 3. Bend the star-shaped support up by approx. 30° to 40°. 4. Detach the color-coding plate by moving the support sideways this way and that.

Disassembling color-coding plates Use a screwdriver to lever the color-coding plates from their supports.

See also Order numbers and accessories (Page B-1)

Page 18: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Assembling 2.4 Assembling-color plates

PN/PN coupler 2-4 Installation and Operating manual, 08/2006, A5E00717043-01

Page 19: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 3-1

Connecting 33.1 Electrical isolation and grounding

3.1.1 Introduction

Redundant 24 V DC power supply You can connect the PN/PN coupler to two independent 24 V DC power supplies. Only one 24 V DC power supply is ever active at any one time. If one power supply fails, the other automatically becomes active. During parameterization, you identify which power supply (PS1, PS2 or both) are connected and are to be diagnosed. You need only connect up one 24 V DC power supply to operate the PN/PN coupler.

Properties of the PN/PN coupler ● Both PROFINET IO subnets are electrically isolated from one another. ● Both PROFINET IO subnets are electrically isolated from the 24 V DC power supply. ● Both 24 V DC power supplies are electrically isolated from one another. ● The PROFINET IO subnet to X1 and the logic of the PN/PN coupler are electrically

linked.

Ungrounded incoming supply Ungrounded operation of the PN/PN coupler is possible with a 24 V DC power supply.

See also Parameters (Page 4-8)

Page 20: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Connecting 3.1 Electrical isolation and grounding

PN/PN coupler 3-2 Installation and Operating manual, 08/2006, A5E00717043-01

3.1.2 General operating rules and regulations

Introduction As a part of plants or systems the modules described require adherence to specific rules and regulations depending on the application. The most important rules, which you must observe for safe integration into a plant or system, are listed below.

Specific application Please observe the safety and accident prevention regulations applying to specific applications (e.g. machine protection guidelines).

EMERGENCY STOP equipment EMERGENCY STOP devices according to IEC 6204 (coincides with VDE 113) must remain effective during all operating modes of the plant or system.

System startup after certain events The table below identifies situations you must pay attention to when the system starts up after the occurrence of certain events.

When ... ... • starting up after a voltage dip or

power failure, • starting up after bus communication

has been interrupted,

dangerous operating states must not occur. If necessary actuate an EMERGENCY-STOP!

• starting up after unlocking the emergency stop device,

• starting up without the IO controller activating the IO devices,

the start up must always be controlled and defined.

24 V DC power supply The table below identifies what you must pay attention to regarding the 24V supply.

When ... Requirements ... Buildings External lightning protection 24 V DC supply lines, signal lines

Internal lightning protection Provide lightning protection (e.g. lightning protection units)

24V supply Safety extra-low voltage (SELV) with guaranteed electrical isolation.

Page 21: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Connecting 3.2 Connections

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 3-3

Note You will find information about lightning protection in the installation manual Automation system S7-300; setting up.

Protection from external electrical impacts The table below identifies what you must pay attention to when protecting against electrical impacts or errors.

When ... ensure that ... all plants or systems in which the modules are integrated

... the plant or system is connected to the protective conductor so that the electromagnetic interference is discharged.

Connecting leads, signal and bus lines

... the arrangement of the wiring and installation are correct

3.2 Connections

Connections of the PN/PN coupler The following picture shows you all the connections you can make to and from the PN/PN coupler:

Figure 3-1 Connections of the PN/PN coupler

① PROFINET IO subnet 1 (X1) ③ Power supply 1 (24 V DC) ② PROFINET IO subnet 2 (X2) ④ Power supply 2 (24 V DC)

Page 22: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Connecting 3.3 Connecting the power supply

PN/PN coupler 3-4 Installation and Operating manual, 08/2006, A5E00717043-01

3.3 Connecting the power supply

Required tool In order to connect the power supply, you will need a screwdriver with a 3 mm blade width.

Power supply unit You may only use PELV-type power supply units with a guaranteed electrically isolated extra-low voltage (≤ DC 60V).

Redundant power supply You can supply the PN/PN coupler from two voltage sources (redundant power supply): ● If one voltage source fails, the PN/PN coupler automatically changes over to the other

voltage source. ● If both connections (PS1 / PS2) are energized, the PN/PN coupler will automatically use

the PS1 voltage source. ● If you only connect the PN/PN coupler to one power supply, you should preferably use

PS1. Note

You can use the diagnostics to assess whether the PN/PN coupler is connected to both 24 V DC power supplies.

Connection for power supply The power supply connections for the 24V power supply are located at the front of the PN/PN coupler. The connections have the following functions:

Figure 3-2 Power supply for the PN/PN coupler

① + 24V DC from subnet 1 (X1) ⑤ + 24V DC from subnet 2 (X2) ② Ground of subnet 1 (X1) ⑥ Ground of subnet 2 (X2) ③ Looping on + 24V DC from subnet 1 (X1) ⑦ Looping on + 24V DC from subnet 2 (X2) ④ Looping on ground of subnet 1 (X1) ⑧ Looping on ground of subnet 2 (X2)

The maximum cross-section of the connection is 2.5 mm2. There is no strain relief. The connecting plug allows you to loop on the power supply with no interrupts even when removed.

Page 23: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Connecting 3.4 Connecting PROFINET IO

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 3-5

Procedure 1. Strip the wires to a length of 10 mm. 2. Insert line into round opening on connecting plug until stop is reached. (In its delivery

condition, the connecting plug is plugged into the power supply connection.) If you have a redundant PN/PN coupler power supply, connect a second power supply to the second connecting plug. If you only use one voltage source, you should preferably use PS1.

3. Plug the wired connecting plug(s) on to the power supply connection on the PN/PN coupler.

3.4 Connecting PROFINET IO

Requirements ● Note the details given in the chapter "General operating rules and regulations".

Required tool ● Screwdriver with 2.5 mm ● Industrial Ethernet Fast Connect stripping tool (6GK1 901-1GA00) (stripping tool for

Industrial Ethernet Fast Connect installation cables)

Bus cable and connector Only use the accessories specified in the chapter "Order numbers and accessories" for PROFINET IO.

Required accessories ● PROFINET connector (according to the specifications in the PROFINET Installation

Guide) ● Industrial Ethernet Fast Connect installation cables

The following are suitable:

Fast Connect standard cable 6XV1840-2AH10 Fast Connect trailing cable 6XV1840-3AH10 Fast Connect marine cable 6XV1840-4AH10

Assembling a bus connector Assemble the PROFINET connector according to the specifications in the PROFINET Installation Guide.

Page 24: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Connecting 3.4 Connecting PROFINET IO

PN/PN coupler 3-6 Installation and Operating manual, 08/2006, A5E00717043-01

Procedure 1. Insert the bus connector into the PROFINET connection. 2. If required, use cable ties to secure the cables to the PN/PN coupler enclosure. 3. Close the PN/PN coupler flap.

See also Order numbers and accessories (Page B-1)

Page 25: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 4-1

Configuring and commissioning 44.1 Configuring and commissioning of the PN/PN coupler (overview)

Overview The table below identifies the steps required for commissioning.

Table 4-1 Procedure for PN/PN coupler configuration and commissioning

Step Activity Content More information in chapter 1 Assembling Assemble the PN/PN coupler on the mounting rail. "Assembling" 2 Wire Connect PN/PN coupler to power supply and PROFNET

IO. "Connecting"

• With STEP 7 "Configuring the PN/PN coupler with STEP 7"

3 Configuring the PN/PN coupler

• With another configuring tool "Configuration of the PN/PN coupler with another configuring tool"

4 Parameterization Set parameters for PN/PN coupler in STEP 7 "Parameters" and online help for STEP 7

5 Commissioning the PN/PN coupler

Switch on PN/PN coupler and load configuration. "Commissioning the PN/PN coupler"

Page 26: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Configuring and commissioning 4.2 Configuring the PN/PN coupler with STEP 7

PN/PN coupler 4-2 Installation and Operating manual, 08/2006, A5E00717043-01

4.2 Configuring the PN/PN coupler with STEP 7

4.2.1 Requirements

Requirements To configure the PN/PN coupler, you will need: ● STEP 7 Version 5.4 or higher, Service Pack 1

4.2.2 Configuring the PN/PN coupler with STEP 7

Introduction For standard operations, you can configure the PN/PN coupler with STEP 7. If you have configured both subnets in a project, STEP 7 will assist you with the correct configuration. If you have distributed the two subnets among two STEP 7 projects, you will have to configure the PN/PN coupler separately in each of the two projects.

Notice

Note the following requirements for coupling the two subnets: • An output module of the same length must be configured at the same slot in another

subnet for each input module in a subnet. • An input module of the same length must be configured at the same slot in another

subnet for each output module in a subnet.

Configuring the PN/PN coupler 1. Start STEP 7 with your project and open HW Config. 2. From the hardware catalog, directory PROFINET IO\Gateway\PN/PN Coupler, drag the

PN/PN coupler to the PROFINET network. 3. Double-click on the PN/PN coupler symbol. 4. Enter a device name for the PN/PN coupler and confirm by clicking on "OK".

This device name must be unique on the Ethernet subnet. The device name must satisfy the DNS conventions. You will find more information about assigning device names in the online help for STEP 7.

5. Specify which bus end (X1 or X2) of the PN/PN coupler you are configuring. If you want to configure the left-hand bus end (X1), you do not need to undertake any more settings at this point. For configuring the right-hand bus end (X2), proceed as follows: – Click on the PN/PN coupler symbol. – The PN/PN coupler's 16 slots appear in the station window in the bottom section of

HW Config. – Double-click on the line for slot 0 - the "Properties - PN/PN coupler" window opens. – Click the "Coupling" tab and at "Configuration for:", select bus end "X2".

Page 27: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Configuring and commissioning 4.2 Configuring the PN/PN coupler with STEP 7

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 4-3

Note In order to operate the PN/PN coupler, the left bus end (X1) and right bus end (X2) must always be separately configured and these may also be located in different projects. Ensure that you have configured the respective proper bus end X1 or X2. Configuration with an incorrect assignment will be rejected by the bus end of the PN/PN coupler in question.

Note

We recommend assign the PN/PN coupler a device name online. The alternative of calling up the menu item "Target system/write device name on memory card …" withinHW Config can only be used if both coupler ends (X1 and X2) are present in one project in STEP7 V5.4 SP1.

Configuration of the PN/PN coupler slots You configure the input and output ranges in the station window. 1. Assign the slots with a universal module starting with slot 1. 2. In the "Addresses" tab of the universal module, select the I/O type (input, output,

input/output) and specify the module length in bytes as well as the addresses of the inputs and outputs.

3. Confirm your entries by clicking on "OK".

Result Configuration for one end of the PN/PN coupler is complete Repeat configuration of the PN/PN coupler and PN/PN coupler slots for the other end and ensure that you supplement the I/O modules consistently with the other bus end.

Coupling both subnets Once you have assigned one end of the PN/PN coupler with I/O modules, STEP 7 provides a help function which can be used to automatically assign the other end with suitable I/O modules. The two bus ends X1 and X2 must however be in the same project.

Page 28: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Configuring and commissioning 4.2 Configuring the PN/PN coupler with STEP 7

PN/PN coupler 4-4 Installation and Operating manual, 08/2006, A5E00717043-01

Example In this example, we are assuming that the left-hand end (X1) has already been assigned with I/O modules. To apply the "Coupling" function to the right-hand end (X2), proceed as follows: 1. Double-click on the line for slot 0 in the station window of the PN/PN coupler which

represents the right-hand end (X2). The "Properties - PN/PN coupler" window opens. 2. Click the "Coupling" tab and at "Subnet", select the Ethernet subnet of peer subnet X1. 3. Under "Device name", select peer subnet X1. 4. The "Configuration for:" field is assigned automatically depending on which bus end is

configured in the peer subnet. 5. Confirm your entries by clicking on "OK" All I/O modules in end X2 of the PN/PN coupler are now supplemented as appropriate for end X1 and the I/O type and module lengths are specified. You can change the address ranges of the I/O modules without the configuration becoming inconsistent. Bus end X2 is now also entered as a peer subnet in the "Coupling" tab of peer subnet X1. If you have specified the two ends of a PN/PN coupler as peer subnets using the "Coupling" function and you have a configuration between the two ends which is not consistent, an incorrect configuration will be flagged up when you run the "Save and compile" function in STEP 7.

Tip We would recommend the following procedure if you make changes to a peer subnet: 1. Undertaking changes (e.g. adding I/O modules) 2. Switch to the peer subnet and in the "Coupling" tab, click on "OK" 3. Run the "Save and compile" function for both stations The configuration is thus always consistent.

Page 29: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Configuring and commissioning 4.2 Configuring the PN/PN coupler with STEP 7

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 4-5

4.2.3 Example: Configuration of the inputs/outputs of the PN/PN coupler with STEP 7

Introduction This example illustrates typical configuration of the PN/PN coupler with STEP 7.

Problem definition The following assumptions apply to the example: ● Bus end X1:

You intend to transfer the following inputs/outputs to the IO controller in subnet 2: 2-byte inputs 16-byte outputs 8-byte inputs 2-byte outputs 3-byte inputs / 5-byte outputs

● Bus end X2: You intend to transfer the following inputs/outputs to the IO controller in subnet 1: 2-byte outputs 16-byte inputs 8-byte outputs 2-byte inputs 5-byte inputs / 3-byte outputs

Page 30: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Configuring and commissioning 4.2 Configuring the PN/PN coupler with STEP 7

PN/PN coupler 4-6 Installation and Operating manual, 08/2006, A5E00717043-01

Configuration of the PN/PN coupler in subnet 1 with STEP 7 Configuration of the PN/PN coupler in subnet 1 (bus end X1) is as follows:

Figure 4-1 Example: Configuration of the PN/PN coupler in subnet 1

Configuration of the PN/PN coupler in subnet 2 with STEP 7 Configuration of the PN/PN coupler must be exactly diametrically opposed tothe configuration in subnet 1. Configuration of the PN/PN coupler in subnet 2 (bus end X2) is then as follows:

Figure 4-2 Example: Configuration of the PN/PN coupler in subnet 2

Page 31: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Configuring and commissioning 4.3 Configuration of the PN/PN coupler with another configuring tool

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 4-7

4.3 Configuration of the PN/PN coupler with another configuring tool

Introduction You configure the PN/PN coupler using a GSD file. Using this file, the PN/PN coupler is incorporated in your configuring tool as an IO device. You can download the GSD file from the following location: http://support.automation.siemens.com/WW/view/en/19699080

GSD file The following GSD file is available for the PN/PN coupler: GSDML-V2.1-Siemens-pnpn_ioc-"Date in format yyyymmdd".xml You will find more information about this procedure in the online help for STEP 7.

Configuring of the PN/PN coupler You configure the PN/PN coupler with your configuring tool as you would for any other IO device with PROFINET IO. To do this, load the entire GSD file for the PN/PN coupler into your configuring tool. You will have to configure the PN/PN coupler separately in each of the two subnets. To do this, select the device labeled as X1 or X2 (this does not apply to migration GSD). When assigning a device name for the PN/PN coupler, note the following: This device name must be unique on the Ethernet subnet. The device name must satisfy the DNS conventions. When configuring via GSD file, you have a choice of input, output and mixed modules, each of which have a fixed length. Assistance to ensure the correct coupling configuration for the two subnets (as with STEP 7) is not available when configuring via GSD file.

Page 32: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Configuring and commissioning 4.4 Parameters

PN/PN coupler 4-8 Installation and Operating manual, 08/2006, A5E00717043-01

4.4 Parameters

Table 4-2 Parameters for the PN/PN coupler

Range of values Default setting Voltage check PS1 deactivated / activated deactivated Voltage check PS2 deactivated / activated deactivated Data validity display DIA deactivated / activated deactivated

The parameters for the two ends of the PN/PN coupler can be set separately. PS1 and PS2 are not assigned to one end and can be monitored separately on both ends. Interrupts (e.g. when monitoring a power supply) are generated separately for each end. The data validity display DIA may only be activated if inputs in the affected end of the PN/PN coupler were configured.

Voltage check PS1 / PS2 Once voltage check PS1 / PS2 has been released, the PN/PN coupler diagnoses the power supply failure at connection PS1 or PS2. Only activate the voltage check if the corresponding power supply is actually connected.

Data validity display DIA The data validity display DIA is used to establish whether the IO controller connected via the PN/PN coupler from the "other" subnet is still supplying valid data. The data's validity is always shown in bit 0 of the least significant input byte of the PN/PN coupler: Bit 0 = 1: received data are valid, all user data flags are "Good". Bit 0 = 0: received data are invalid (e.g. because a PN/PN coupler interface is faulty or because the coupler in the "other" subnet has failed). At least one user data flag is "Bad". The least significant input byte comes from the lowest slot number of the first input module.

Warning If "DIA" is activated, then the first bit of the first configured input byte must not be used for input data! When using the data validity display DIA, we recommend not using the entire first byte of the input data for inputs!

Page 33: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Configuring and commissioning 4.5 SNMP

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 4-9

4.5 SNMP The PN/PN coupler supports the Ethernet service SNMP. MIB-2 (RFC1213) is supported. R/W objects can be changed using SNMP tools and are saved in the module. Each of the two bus ends (X1, X2) of the PN/PN coupler has its own memory area for the SNMP data.

Reset to factory settings SNMP parameters saved as remnants are reset to factory settings in the HW Config dialog "Target system > Ethernet > Edit Ethernet participants", "Reset" button under "Reset to factory settings (as of STEP 7 V5.3 SP 3).

Note

The "Reset to factory settings" function is only available if both bus ends X1 and X2 of the PN/PN coupler are not exchanging data with an IO controller.

The following data are not deleted when resetting: ● The device name which is saved on the SIMATIC Micro Memory Card ● The MAC address ● The I&M data The PN/PN coupler must be switched off and on again in order for the PN/PN coupler to be able to again exchange data with an IO controller after performing the "Reset to factory settings" function. The device name on the SIMATIC Micro Memory Card is then again transferred to the PN/PN coupler and can again be reached from the assigned IO controllers.

Note

Deleting the device name To prevent a new module from starting up with an "unknown" device name, delete the device name from the SIMATIC Micro Memory Card. To do this, open the properties dialog of the PN/PN coupler in HW Config for each bus end (X1 and X2). Confirm each of the properties dialog without entering a device name in the "Assigning device name" field.

More information on SNMP can be found in the manual PROFINET system description.

Page 34: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Configuring and commissioning 4.6 Commissioning the PN/PN coupler

PN/PN coupler 4-10 Installation and Operating manual, 08/2006, A5E00717043-01

4.6 Commissioning the PN/PN coupler

Requirements Before you can commission the PN/PN coupler, the following requirements must be satisfied: ● You must have fully set up and wired the PN/PN coupler as described in the chapters

"Assembling" and "Connecting". ● You must have fully set up the two PROFINET IO subnets. PROFINET IO is ready. ● You must have plugged a SIMATIC Micro Memory Card into the slot provided in the

PN/PN coupler. ● You must have configured the PN/PN coupler (X1 and X2). ● You must have assigned a device name to the PN/PN coupler per subnet. ● You must have undertaken parameterization for the PN/PN coupler.

Commissioning the PN/PN coupler 1. Switch on the power supply for the PN/PN coupler 2. Load the configuration into the target system separately for X1 and X2 using Target

system > Load into module.

Page 35: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 5-1

Operating 55.1 Response times of the PN/PN coupler

Overview This section covers the average time it takes to transfer data from the IO controller (subnet 1) via the PN/PN coupler to the IO controller (subnet 2).

Response times The time between an IO controller writing data in the output area of the process image and the time when this data can be read in the process image of the second IO controller depends on the following parameters: ● CPU cycle time of the two IO controllers ● Bus cycle time of the associated IO controllers ● Copy time within the PN/PN coupler (TCOPY) ● Total data length in bytes (input/output) The copy time within the PN/PN coupler is not dependent on the data transfer rate used. It consists of the copy routine for the inputs and for the outputs. The following maximum values apply: ● Outputs: TCOPY = 160 µs + n x 0.4 µs ● Inputs: TCOPY = 200 µs + n x 0.8 µs The two times should be added together. Even with the maximum size of the data which can be transferred (256-byte input data and 256-byte output data), the copy time is < 1 ms.

Influencing factors for the response times The following applies to time-critical applications: ● Exchange as little data as possible via the PN/PN coupler. ● Do not request diagnostic data from the IO controller. ● Do not activate the data validity display DIA.

Page 36: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Operating 5.2 SIMATIC Micro Memory Card

PN/PN coupler 5-2 Installation and Operating manual, 08/2006, A5E00717043-01

5.2 SIMATIC Micro Memory Card

Insertion of the SIMATIC Micro Memory Card A SIMATIC Micro Memory Card is used as the memory medium for the PN/PN coupler. The following data is saved on the SIMATIC Micro Memory Card. ● Technology data (device names) ● Data for a firmware update

Note

On one SIMATIC Micro Memory Card, you can save either technology data or update data.

Service life of a SIMATIC Micro Memory Card The life of a SIMATIC Micro Memory Card essentially depends on the following factors: ● Number of deletion or programming operations ● External factors, such as ambient temperature At an ambient temperature up to 60 °C a SIMATIC Micro Memory Card has a service life of 10 years at maximum 100,000 write/delete sequences.

Caution Possible data loss If the maximum number of write/delete operations is exceeded, data loss is possible.

Applicable SIMATIC Micro Memory Cards The following memory modules are available for use: A SIMATIC Micro Memory Card 64k is sufficient for storing the name of the device. The SIMATIC Micro Memory Cards with at least 2 MB of storage capacity are required when conducting a firmware update. You will find the order numbers for the memory modules in the appendix "Order numbers and accessories".

Inserting/replacing the card The SIMATIC Micro Memory Card is designed so that it can also be removed and inserted while current is flowing. The beveled corner of the SIMATIC Micro Memory Card prevents it from being inserted backwards (reverse polarity protection). The receptacle is located on the top of the PN/PN coupler. If necessary, remove the PN/PN coupler to access the receptacle. To remove the SIMATIC Micro Memory Card, gently press it downwards. The SIMATIC Micro Memory Card is thereby unlocked and is released from the receptacle.

See also View (Page 1-3)

Page 37: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Operating 5.3 Updating firmware

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 5-3

5.3 Updating firmware You can update the PN/PN coupler's firmware: ● Via PROFINET IO, e.g. using HW Config or in the SIMATIC Manager using Target

system > Display accessible nodes ● Using the SIMATIC Micro Memory Card To update the firmware, you will need files (*.UPD) containing the current firmware. The firmware can be updated via both PROFINET IO interfaces. For performance reasons, we would recommend updating the firmware via interface X1. The following requirements must be satisfied: ● The PN/PN coupler whose firmware you want to update must be accessible online. ● The files with the current firmware version must be available in the file system of your

programming device or PC. The STEP 7 online help system provides information on how to proceed.

5.3.1 Updating firmware using SIMATIC Micro Memory Card

Requirements To update the firmware of a PN/PN coupler, you will need: ● STEP 7 Version 5.3 or higher, Service Pack 1 ● A SIMATIC Micro Memory Card with at least 2 MB of memory ● A PC or PG with equipment for writing to a SIMATIC Micro Memory Card

Procedure You update the firmware in two stages: 1. Transferring the update files to a SIMATIC Micro Memory Card. 2. Carrying out the firmware update for a PN/PN coupler.

Transferring the update files to a SIMATIC Micro Memory Card 1. Use Windows Explorer to create a new directory. 2. Download the required update file from the Internet into this directory. 3. Unpack this update file into this directory. This directory contains three files with the

extension UPD. 4. Insert a SIMATIC Micro Memory Card (≥ 2 MB) into the programming device or writing

device. 5. In the SIMATIC Manager, select the menu command Target system > Update operating

system. 6. If necessary, confirm deletion of the SIMATIC Micro Memory Card. 7. In the dialog box displayed, select the directory containing the UPD files. 8. Double-click one of the UPD files. The data are written to the SIMATIC Micro Memory

Card. The update files are now contained on the SIMATIC Micro Memory Card.

Page 38: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Operating 5.4 Replacing defective PN/PN coupler

PN/PN coupler 5-4 Installation and Operating manual, 08/2006, A5E00717043-01

Carrying out the firmware update 1. De-energize the PN/PN coupler and plug the SIMATIC Micro Memory Card containing the

firmware update into the receptacle. 2. Switch on the power supply for the PN/PN coupler.

The PN/PN coupler automatically detects the SIMATIC Micro Memory Card containing the firmware update and starts to update the module. During the firmware update, the SF and BF LEDs on end X1 light up while the ON LED is off. Once the update is complete, the BF-LED on end X1 flashes with 0.5 Hz.

3. De-energize the PN/PN coupler and remove the SIMATIC Micro Memory Card containing the firmware update.

4. Plug in the SIMATIC Micro Memory Card containing the device name and switch on the power supply.

The PN/PN coupler boots up with the new firmware and is then ready.

5.4 Replacing defective PN/PN coupler

Procedure The following list shows the steps required for replacing a defective PN/PN coupler. 1. Remove the bus connectors from the PROFINET IO interfaces of the defective PN/PN

coupler. 2. Remove the power supply unit from the defective PN/PN coupler. 3. Remove the SIMATIC Micro Memory Card containing the device name from the defective

PN/PN coupler. 4. Replace the defective PN/PN coupler. 5. Plug in the SIMATIC Micro Memory Card containing the device name in the new PN/PN

coupler. 6. Plug the power supply connection into the new PN/PN coupler. 7. Plug the bus connectors into the PROFINET IO interfaces of the new PN/PN coupler.

Page 39: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Operating 5.5 Identification data

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 5-5

5.5 Identification data

Definition Identification data are information saved in a module which assist the user when: ● checking the system configuration ● locating hardware modifications in a system ● correcting errors in a system Identification data enable modules to be uniquely identified online. In STEP 7, the identification data are displayed in the tabs "Module status - PN/PN coupler" and "Properties – PN/PN coupler" (see online help for STEP 7).

Reading identification data Each of the two bus ends (X1, X2) of the PN/PN coupler has its own memory area for the identification data. You can enter or interrogate the identification data for each of the two bus ends separately. You can access specific identification data using Read data record. You will find the appropriate piece of identification data under the associated data record index. The data records are structured using the following principle:

Table 5-1 Basic structure of data records which contain ID data.

Content Length (bytes) Coding (hex) Header information BlockType 2 I&M0: 0020

I&M1: 0021 I&M2: 0022 I&M3: 0023

BlockLength 2 I&M0: 0038 I&M1: 0038 I&M2: 0012 I&M3: 0038

BlockVersionHigh 1 01 BlockVersionLow 1 00 Identification data Identification data (see following table) I&M0: 54

I&M1: 54 I&M2: 16 I&M3: 54

Page 40: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Operating 5.5 Identification data

PN/PN coupler 5-6 Installation and Operating manual, 08/2006, A5E00717043-01

The data structures in the data records correspond to the PROFINET IO definitions.

Table 5-2 Identification data

Identification data Access Default setting Explanation Identification data 0: (Data record index AFF0 hex) VendorIDHigh Read (1 byte) 00 hex VendorIDLow Read (1 byte) 2A hex

The name of the manufacturer is stored here. (42 dec = SIEMENS AG)

Order_ID Read (20 byte) 6ES7158-3AD00-0XA0 Order number of the module IM_SERIAL_NUMBER Read (16 byte) Serial number (device-

specific) IM_HARDWARE_REVISION Read (2 byte) 1 Depending on HW version IM_SOFTWARE_REVISION Read Firmware version • SWRevisionPrefix (1 byte) V, R, P, U, T • IM_SWRevision_Functional_

Enhancement (1 byte) 00 - FF hex

• IM_SWRevision_Bug_Fix (1 byte) 00 - FF hex • IM_SWRevision_Internal_

Change (1 byte) 00 - FF hex

This indicates the firmware version of the module.

IM_REVISION_COUNTER Read (2 bytes) - This indicates the parameterized changes on the module.

IM_PROFILE_ID Read (2 bytes) 0000 Generic Device IM_PROFILE_SPECIFIC_TYPE Read (2 bytes) 0005 hex on interface modules IM_VERSION Read • IM_Version_Major (1 byte) • IM_Version_Minor (1 byte)

0101 hex This indicates the version of the identification data (0101 hex = Version 1.1)

IM_SUPPORTED Read (2 bytes) 000E hex This indicates the identification data available (I&M1 to I&M3)

Maintenance data 1: (Data record index AFF1 hex) IM_TAG_FUNCTION Read/write (32 bytes) - Enter a system-wide unique

identifier for the module here.

IM_TAG_LOCATION Read/write (22 bytes) - Enter the installation location of the module here.

Maintenance data 2: (Data record index AFF2 hex) IM_DATE Read/write (16 bytes) YYYY-MM-DD HH:MM Enter the installation date of

the module here. Maintenance data 3: (Data record index AFF3 hex) IM_DESCRIPTOR Read/write (54 bytes) - Enter a comment on the

module here.

Page 41: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 6-1

Diagnostics 66.1 Diagnostics via LED displays

LEDs on the PN/PN coupler Descriptions of the LEDs on the PN/PN coupler and their function can be found below.

SF 1 Group error for PROFINET IO subnet 1 (red) SF 2 Group error for PROFINET IO subnet 2 (red) BF 1 Bus fault for PROFINET IO subnet 1 (red) BF 2 Bus fault for PROFINET IO subnet 2 (red) ON Power supply 24 V DC (green) LINK Connection to a switch or IO controller (green), per interface RX/TX Data exchange (yellow), per interface

Page 42: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Diagnostics 6.1 Diagnostics via LED displays

PN/PN coupler 6-2 Installation and Operating manual, 08/2006, A5E00717043-01

Status and error displays using LEDs on the PN/PN coupler

Table 6-1 Status and error displays on the PN/PN coupler

LEDs SF BF ON

Meaning Remedy

off off off The PN/PN coupler is not energized or there is a hardware defect on the PN/PN coupler.

Switch on the DC 24 V power supply for the PN/PN coupler.

* * on The PN/PN coupler is energized. —

* Flashing 0.5 Hz

on Incorrect or no connect telegram - there is no exchange of data between the IO controller and interface module (IO device), the IO device is however physically linked to the switch. Causes: • Incorrect device name • The IO controller is switched off, defective or

there is no bus cable to the IO controller.

• Check the device names. • Assign a valid device name to the PN/PN

coupler. • Check the IO controller

* on on There is no link signal on either of the two ports at the corresponding bus end.

• Establish a connection to the IO controller (via a switch).

• Assign a valid device name to the PN/PN coupler.

• Check the bus configuration. • Check that the bus connector is correctly

inserted. • Check whether the bus cable to the I/O

controller is interrupted. on * on • Configured configuration of two ends of

PN/PN coupler does not match actual configutation.

• Voltage monitoring PS1+PS2 was configured but only one power supply is connected or one power supply has failed

• Check that configuration is identical at the two ends (e.g. using STEP 7) and correct the parameterization error.

• Ensure that there are two power supplies.

on off on • No SIMATIC Micro Memory Card is inserted. • No suitable SIMATIC Micro Memory Card is

inserted (i. e. no SIMATIC Micro Memory Card from Siemens).

In this state, the IO device cannot be accessed.

• Format the SIMATIC Micro Memory Card • Before activating the power supply, insert

an empty SIMATIC Micro Memory Card into the PN/PN coupler.

on on on A brand new SIMATIC Micro Memory Card is being formatted.

Wait until the formatting sequence is complete. This may take several minutes. The formatting sequence is completed when the SF LED goes out.

off off on Data exchange is taking place between the IO controller and PN/PN coupler. Specified and actual configuration of PN/PN coupler match.

on on off FW update busy —

off Flashing 0.5 Hz

off FW update successfully completed —

on Flashing 0.5 Hz

off External error during FW update (e.g. incorrect FW)

Use the correct FW for the update.

on Flashing 2 Hz

off Internal error during FW update (e.g. write/read fault)

Repeat the FW update.

*) not relevant

Page 43: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Diagnostics 6.1 Diagnostics via LED displays

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 6-3

LEDs

LINK RX/TX Meaning Remedy

off off No connection to switch/IO controller. Check whether a uniform baud rate is set for all devices on the line. Check that the bus cable is plugged in.

on * Connection to switch/IO controller. — on on Transmission/reception is in progress —

LEDs PS1 PS2

Meaning Remedy

on on The PN/PN coupler has two power supplies (to PS1 and PS2).

The PN/PN coupler has one power supply (to PS1).

on off

With redundant power supply: Power supply to PS2 has failed.

Also power the PN/PN coupler with voltage PS2.

The PN/PN coupler has one power supply (to PS2).

off on

With redundant power supply: Power supply to PS1 has failed.

Also power the PN/PN coupler with voltage PS1.

off off The PN/PN coupler is not being powered. Power the PN/PN coupler with voltage to PS1 or to PS1 and PS2.

Page 44: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Diagnostics 6.2 Diagnostics by user program

PN/PN coupler 6-4 Installation and Operating manual, 08/2006, A5E00717043-01

6.2 Diagnostics by user program

6.2.1 Manufacturer-specific diagnostics The PN/PN coupler produces manufacturer-specific diagnostics for the following events: ● Failure of power supplies PS 1 and PS 2 ● Other network end is not configured or has failed ● Configuration of subnets X1 and X2 differs ● Parameter DIA (data validity) set but no inputs configured Manufacturer-specific diagnostics are 4 bytes each. The following table lists the assignments available.

Byte 0 1 2 3 Content 1 1 ─ failure of power supply on left

2 ─ failure of power supply on right 0 0

2 1 ─ Other network end not configured or failed 2 ─ Configuration of subnets X1 and X2 differs 4 ─ Parameter DIA (data validity display) set but no input data configured

0 0

If the IO controller fails or the bus cable is removed, the PN/PN coupler on the other bus end supplies input values featuring substitute value "0" and sets the user data flag to "Bad". If the two bus ends of the PN/PN coupler do not have matching configuration, in the dialog "Module status" of the last configured bus end, STEP 7 also supplies information on the slots with differing configuration.

6.2.2 Interrupts The I/O device generates interrupts as a reaction to specific error events. Interrupts are evaluated based on the I/O controller used. The PN/PN coupler supports the following interrupts: ● Diagnostic interrupts

If there is communication between the IO controller and PN/PN coupler, manufacturer-specific diagnostics of the PN/PN coupler are also active as interrupts which result in an OB 82 being called up in a SIMATIC CPU.

● ReturnOfSubmodule interrupts User data flags provide information about the validity of the IO data of a slot. If a user data flag changes from "Bad" to "Good", a ReturnOfSubmodule interrupt is produced which results in an OB 83 being called up in a SIMATIC-CPU. The bus end of the PN/PN coupler which has already been configured produces a ReturnOfSubmodule interrupt during configuration of the other bus end for each slot matching in the configuration.

Page 45: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Diagnostics 6.2 Diagnostics by user program

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 6-5

6.2.3 Diagnostics readout

Options for reading out the diagnostic data Manufacturer-specific diagnostic data can be evaluated using the corresponding data records (e.g 0x800B) or using diagnostics interrupts.

Table 6-2 Reading out the diagnostic data with STEP 7

Automation system with

IO controller

Module or tab in STEP 7

Application See ...

in HW Config using Station > Open online

Device diagnostics in form of plain text on STEP 7 interface (in the Quick View, Diagnostics View, or Module Status windows)

"Diagnosing hardware" in STEP 7 online help

SFB 52 "RDREC"

Read data records from the IO device

SFB see STEP 7 online help (system functions/function blocks)

SIMATIC S7

SFB 54 "RALRM"

Receiving interrupts from the IO device

SFB see STEP 7 online help (system functions/function blocks)

Structure of diagnostic data records You will find the structure of the diagnostic data records and examples for programming in the programming manual From PROFIBUS DP to PROFINET IO in the chapters "Structure of diagnostic data records" or "Examples of diagnostic data records". The data records which the PN/PN coupler supports are based on standard PROFINET IO - Application Layer Service Definition V2.0. You can download the standard free-of-charge from http://www.profibus.com.

Page 46: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Diagnostics 6.2 Diagnostics by user program

PN/PN coupler 6-6 Installation and Operating manual, 08/2006, A5E00717043-01

6.2.4 Example of diagnostics

Introduction This example illustrates how to call up typical diagnostics for the PN/PN coupler.

Problem definition The following assumptions apply to the example: ● Power supply PS2 (right) has failed. ● The PN/PN coupler has diagnostics address 8180 (corresponding to 1FF4H). ● The following picture shows an example of the structure of a diagnostic evaluation.

Figure 6-1 Example of structure for a diagnostic evaluation of the PN/PN coupler

There are two ways of reading out the diagnostic interrupt: ● using SFB 52 ("RDREC") ● using SFB 54 ("RALRM")

Page 47: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Diagnostics 6.2 Diagnostics by user program

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 6-7

Solution using SFB 52 ("RDREC") In OB 1, call up SFB 52 and read out a diagnostic data record (e.g. C00C or E00C).

Table 6-3 STL code for reading out diagnostics

STL

AN M10.3 // Once the reading process is complete (BUSY flag = 0)...

AN M10.1 // ...and there is no request trigger for reading the data record (REQ = 0)...

S M10.1 // ...then the transfer of data records begins (REQ = 1)

L W#16#C00C // Use diagnostic data record W#16#C00C

M MW6 // Load W#16#C00C into memory word 6

CALL SFB 52, DB56

REQ :=M10.1 // Request to read the diagnostic data

ID :=W#16#1FF4 // Diagnostics address

INDEX :=MW6 // Data record number

MLEN :=200 // Maximum length of the data to be read

VALID :=M10.2 // Validity of data record

BUSY :=M10.3 // Indication of whether reading request is still active (BUSY=1)

ERROR :=M10.4 // Error flag

STATUS :=MD12 // Error code

LEN :=MW16 // Length of the read data

RECORD :=P#DB52.DBX0.0 BYTE 512

// Destination area for the read data record

U M10.1

R M10.1 // Reset request flag

Create the following structure for DB 52:

Address Name Type Initial value Comment

0.0 STRUCT +0.0 ds ARRAY[1..512] Diagnostics data *1.0

BYTE

=512 END_STRUCT

Page 48: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Diagnostics 6.2 Diagnostics by user program

PN/PN coupler 6-8 Installation and Operating manual, 08/2006, A5E00717043-01

Content of DB 52 after triggering diagnostics:

Address Content Meaning DB52.DBB0 00 H DB52.DBB1 10 H

BlockType W#16#0010: Data record of diagnostic data record type

DB52.DBB2 00 H DB52.DBB3 13 H

BlockLength W#16#0013: 19 more bytes follow

DB52.DBB4 01 H DB52.DBB5 01 H

BlockVersion High and low byte

DB52.DBB6 00 H DB52.DBB7 00 H DB52.DBB8 00 H DB52.DBB9 00 H

API

DB52.DBB10 00 H DB52.DBB11 00 H

SlotNumber W#16#0000: Slot number of interrupt-triggering component

DB52.DBB12 00 H DB52.DBB13 01 H

SubslotNumber W#16#0001: Sub-module slot number

DB52.DBB14 00 H DB52.DBB15 00 H

ChannelNumber W#16#0000: Identification of interrupt source: manufacturer-specific

DB52.DBB16 08 H DB52.DBB17 00 H

ChannelProperties W#16#0800 = 0000 1000 0000 0000: Bit 11 - 12 = 01: pending diagnostics

DB52.DBB18 00 H DB52.DBB19 01 H

UserStructureIdentifier (USI) W#16#0001: manufacturer-specific: Failure of one power supply

DB52.DBB20 02 H DB52.DBB21 00 H DB52.DBB22 00 H

Data B#16#02: Failure of power supply on right

Page 49: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Diagnostics 6.2 Diagnostics by user program

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 6-9

Solution using SFB 54 ("RALRM") In OB 82, call up SFB 54 and read out the diagnostic interrupt data.

Table 6-4 STL code for reading out diagnostic interrupts

CALL SFB 54, DB54

MODE :=1 // Operating mode

F_ID :=DW#16#1FF4 // Log. start address of module from where interrupt is to be received

MLEN :=200 // Maximum length of the interrupt information to be read

NEW := // A new interrupt has been received (NEW = 1)

STATUS := // Error code

ID := // Log. start address of component from where interrupt has been received

LEN := // Length of the read interrupt information

TINFO :=P#DB80.DBX0.0 BYTE 255

// Destination area for OB start information and administrative information

AINFO :=P#DB81.DBX0.0 BYTE 255

// Destination area for header information and additional interrupt information

Create the following structure for DB 80:

Address Name Type Initial value Comment

0.0 STRUCT +0.0 T_INFO ARRAY[1..255] T_INFO *1.0

BYTE

=256 END_STRUCT

Create the following structure for DB 81:

Address Name Type Initial value Comment

0.0 STRUCT +0.0 A_INFO ARRAY[1..255] A_INFO *1.0

BYTE

=256 END_STRUCT

Page 50: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Diagnostics 6.2 Diagnostics by user program

PN/PN coupler 6-10 Installation and Operating manual, 08/2006, A5E00717043-01

Content of DB 80 after triggering diagnostics:

Address Content Meaning DB80.DBB0 39 H DB80.DBB1 42 H DB80.DBB2 19 H DB80.DBB3 52 H DB80.DBB4 C5 H DB80.DBB5 54 H DB80.DBB6 1F H DB80.DBB7 F4 H DB80.DBB8 0D H DB80.DBB9 33 H DB80.DBB10 00 H DB80.DBB11 00 H DB80.DBB12 06 H DB80.DBB13 08 H DB80.DBB14 18 H DB80.DBB15 09 H DB80.DBB16 30 H DB80.DBB17 55 H DB80.DBB18 09 H DB80.DBB19 96 H

Start information OB 82 (Bytes 0-19)

(For structure, see online help OB 82)

DB80.DBB20 80 H DB80.DBB21 01 H

Address of interrupt source

DB80.DBB22 08 H Device type DB80.DBB23 00 H Interrupt info DB80.DBB24 00 H DB80.DBB25 01 H

Flags of PROFINET IO controller connection

DB80.DBB26 06 H DB80.DBB27 04 H DB80.DBB28 00 H DB80.DBB29 2A H DB80.DBB30 00 H DB80.DBB31 01 H

Administrative information

Page 51: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Diagnostics 6.2 Diagnostics by user program

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 6-11

Content of DB 81 after triggering diagnostics:

Address Content Meaning DB80.DBB0 00 H DB81.DBB1 02 H

BlockType W#16#0002: Interrupt information

DB81.DBB2 00 H DB81.DBB3 1B H

BlockLength W#16#001B: 27 more bytes follow

DB81.DBB4 01 H DB81.DBB5 00 H

BlockVersion High and low byte

DB81.DBB6 00 H DB81.DBB7 01 H

AlarmType

W#16#0001: Diagnostic interrupt (incoming) DB81.DBB8 00 H DB81.DBB9 00 H DB81.DBB10 00 H DB81.DBB11 00 H

API

DB81.DBB12 00 H DB81.DBB13 00 H

SlotNumber W#16#0000: Slot number of interrupt-triggering component

DB81.DBB14 00 H DB81.DBB15 01 H

SubslotNumber W#16#0001: Sub-module slot number

DB81.DBB16 00 H DB81.DBB17 00 H DB81.DBB18 00 H DB81.DBB19 01 H

ModulIdentNumber

DB81.DBB20 00 H DB81.DBB21 00 H DB81.DBB22 00 H DB81.DBB23 01 H

SubmodulIdentNumber

DB81.DBB24 B0 H DB81.DBB25 02 H

AlarmSpecifier W#16#B002: Bit 12 = 1: manufacturer-specific diagnostics

DB81.DBB26 00 H DB81.DBB27 01 H

UserStructureIdentifier (USI) W#16#0001: manufacturer-specific: Failure of one power supply

DB81.DBB28 02 H DB81.DBB29 00 H DB81.DBB30 00 H

Data

B#16#02: Failure of power supply on right

Page 52: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Diagnostics 6.2 Diagnostics by user program

PN/PN coupler 6-12 Installation and Operating manual, 08/2006, A5E00717043-01

6.2.5 Data validity display Information covering all stations on the validity of the input data supplied by the other bus end of the PN/PN coupler can be interrogated directly in the user program using the DIA parameter (data validity display).

See also Parameters (Page 4-8)

6.2.6 Evaluation of the user data flag Each IO module is assigned a value in the input or output data message; this value provides a statement on the quality of this user datum. For example, outputs of a specific module can be switched off by means of this without affecting other modules. If inputs or outputs are accessed whose user data flag is "Bad", the corresponding CPU calls up error OB 85 or 122 (depending on whether the datum in question is in the process image or the extended process image of the CPU).

6.2.7 STOP of the IO controller and recovery of the IO device

IO controller STOP When in STOP mode, the IO controller supplies output data with a "Bad" user data flag. The PN/PN coupler does not indicate that the IO controller on the other bus end is in STOP mode by any diagnostics of its own.

Diagnostics after STOP of the IO controller Diagnostics received from the IO device while the IO controller is in STOP mode will not result in the corresponding OBs being started once the IO controller starts up. You have to check OB 100 for the status of the IO device.

Diagnostics after recovery of the IO device During recovery of an IO device, you must use SFB 52 to read data record E00CH. This contains all the diagnostics data for the slots assigned to an IO controller in an IO device.

Page 53: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 A-1

Technical data AA.1 Technical data for PN/PN coupler (6ES7158-3AD00-0XA0)

Overview

Dimensions and weight Dimensions W x H x D (mm) 120 × 132 × 75 Weight 282 g

Module-specific data

Transfer rate • 10 Mbit/s for Ethernet services • 100 Mbit/s full duplex for

PROFINET IO Transmission method 100BASE-TX Auto negotiation Yes Auto crossing Yes Internal switch function Yes Bus protocol PROFINET IO TCP/IP Supported Ethernet services • ping

• arp • Net diagnostics (SNMP) / MIB-2

PROFINET interface 4x RJ45 Manufacturer ID (vendor ID) 002AH Device ID (DeviceID) 0604H

Voltages, currents, potentials

Rated supply voltage DC 24 V (20.4 V ... 28.8 V) • Reverse polarity protection Yes • Power failure bypass Min. 5 ms Electrical isolation of 24 V power supplies • Between backplane bus and electronics • Between Ethernet and electronics Yes • Between power supply and electronics Incoming supply 1: No

Incoming supply 2: Yes Ungrounded operation possible Yes Insulation tested at DC 500 V Current consumption from power supply (1L+) Approx. 400 mA Power loss Approx. 6 W

Page 54: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Technical data A.2 General technical data

PN/PN coupler A-2 Installation and Operating manual, 08/2006, A5E00717043-01

Status, interrupts, diagnostics Power supply status display Yes Interrupts No Diagnostic function Yes • Group error for PROFINET IO subnet 1 • Group error for PROFINET IO subnet 2 • Bus fault for PROFINET IO subnet 1 • Bus fault for PROFINET IO subnet 2 • Monitoring of 24 V power supply of subnet 1 • Monitoring of 24 V power supply of subnet 2 • PN/PN coupler in operation

• Red LED "SF1" • Red LED "SF2" • Red LED "BF1" • Red LED "BF2" • Green LED "PS1" • Green LED "PS2" • Green LED "ON"

A.2 General technical data

A.2.1 Introduction

Scope of the general technical data The general technical data covers: ● The standards and test values that the described components observe and fulfill. ● The test criteria used to test the described components. The general technical data for the following areas is provided below: ● Standards and approvals ● Electromagnetic compatibility ● Transport and storage conditions ● Mechanical and climatic ambient conditions for operation ● Specifications for insulation tests, safety class and degree of protection ● Rated voltage

Page 55: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Technical data A.2 General technical data

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 A-3

A.2.2 Standards and approvals

CE approval The PN/PN coupler satisfies the specifications and safety-related requirements of the following EC directives and is in line with the harmonized European standards (EN), which have been published in the Official Journals of the European Community for programmable logic controls: ● 73/23/EEC "Electrical Equipment for Use within Fixed Voltage Ranges" (Low-Voltage

Directive) ● 89/336/EEC "Electromagnetic Compatibility" (EMC Directive) ● 94/9/EC "Equipment and Protective systems intended for use in Potentially Explosive

Atmospheres" (Explosion Protection Directive) The EU conformity declaration certificates are available for the responsible authorities and are kept at the following address: Siemens AG Automation and Drives A&D AS RD ST Type Test P.O. Box 1963 D-92209 Amberg

Approvals Underwriters Laboratories Inc. complying with ● UL 508 (Industrial Control Equipment) ● CSA C22.2 No. 142 (Process Control Equipment) or Underwriters Laboratories Inc. complying with ● UL 508 (Industrial Control Equipment) ● CSA C22.2 No. 142 (Process Control Equipment) ● UL 1604 (Hazardous Location) ● CSA-213 (Hazardous Location) APPROVED for use in Class I, Division 2, Group A, B, C, D T4; Class I, Zone 2, AEx nC, Group IIC T4

Note

The certifications currently valid can be found on the name plate of the specific module.

Page 56: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Technical data A.2 General technical data

PN/PN coupler A-4 Installation and Operating manual, 08/2006, A5E00717043-01

FM approval Factory Mutual Research (FM) complying with Approval Standard Class Number 3611, 3600, 3810 APPROVED for use in Class I, Division 2, Group A, B, C, D T4; Class I, Zone 2, Group IIC T4 In accordance with EN 60079-15 (Electrical apparatus for potentially explosive atmospheres; type of protection "n")

II 3 G EEx nA II T4

Tick-Mark for Australia The described components meet the requirements of the AS/NZS 2064 (Class A) standard.

IEC 61131 The described components meet the requirements and criteria of the IEC 61131-2 standard (programmable logic controls, part 2: equipment specifications and inspections).

Marine approval (pending) Classification organizations: ● ABS (American Bureau of Shipping) ● BV (Bureau Veritas) ● DNV (Det Norske Veritas) ● GL (Germanischer Lloyd) ● LRS (Lloyds Register of Shipping) ● Class NK (Nippon Kaiji Kyokai)

PROFINET standard The described components are based on the IEC 61158-6-10 standard.

Use in industrial environments SIMATIC products are designed for use in industrial environments.

Requirement for Operating range

Emitted interference Interference immunity Industry EN 61000-6-4:2001 EN 61000-6-2:2001

Page 57: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Technical data A.2 General technical data

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 A-5

Use in residential areas If you use the described components in residential areas, you must ensure limit class B as defined in EN 55011 for the emission of radio interference. The following measures are appropriate for achieving the level of radio interference required for limit class B: ● Installation in grounded cabinets / control boxes ● Use of filters in supply lines

Warning

Personal injury and property damage can occur. Personal injury and property damage can occur in potentially explosive atmospheres if plug-in connections are disconnected during operation. Always de-energize all components in potentially explosive areas before disconnecting plug-in connections.

A.2.3 Electromagnetic compatibility

Introduction This chapter provides you with information on the immunity to interference of the described components as well as on radio interference suppression. The described components meet the requirements of the EMC legislation of the European Community.

Pulse-shaped interferences The table below shows the electromagnetic compatibility of the described components with regard to pulse-shaped interferences. The prerequisite for this is that the system complies with the relevant requirements and guidelines relating to electrical equipment.

Table A-1 Pulse-shaped interferences

Pulse-shaped interference Tested at Corresponds to degree of severity

Electrostatic discharge according to IEC 61000-4-2

8 kV 4 kV

3 (air discharge) 2 (contact discharge)

Burst pulse (fast transients) complying with IEC 61000-4-4

2 kV (supply line) 2 kV (signal line)

3

Surge complying with IEC 61000-4-5 External protective network needed (see installation manual Automation system S7-300, setting up, chapter "Lightning protection and overvoltage protection") • Asymmetric coupling 2 kV (supply line)

2 kV (signal line / data line) • Symmetric coupling 1 kV (supply line)

1 kV (signal line / data line)

3

Page 58: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Technical data A.2 General technical data

PN/PN coupler A-6 Installation and Operating manual, 08/2006, A5E00717043-01

Sinusoidal interferences The table below shows the EMC characteristics of the described components with regard to sinusoidal interferences.

Table A-2 Sinusoidal interferences

Sinusoidal interference Test values Corresponds to degree of

severity HF irradiation (electromagnetic fields) according to IEC 61000-4-3

10 V/m at 80 % amplitude modulation of 1 kHz in the range from 80 MHz to 1000 MHz 10 V/m at 50 % pulse modulation at 900 MHz

3

HF current feed on lines and cable shields according to IEC 61000-4-6

Test voltage 10 V at 80 % amplitude modulation of 1 kHz in the range from 9 kHz to 80 MHz

3

Emission of radio interferences Emission of interference from electromagnetic fields in compliance with EN 55011: limit class A, group 1.

from 30 to 230 MHz < 30 dB (µV/m)Q from 230 to 1000 MHz < 37 dB (µV/m)Q measured at a distance of 30 m

Interference emitted via mains a.c. supply in accordance with EN 55011: limit class A, group 1.

from 0.15 to 0.5 MHz < 79 dB (µV)Q

< 66 dB (µV)M from 0.5 to 5 MHz < 73 dB (µV)Q

< 60 dB (µV)M from 5 to 30 MHz < 73 dB (µV)Q

< 60 dB (µV)M

Page 59: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Technical data A.2 General technical data

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 A-7

A.2.4 Transport and storage conditions

Transport and storage of modules In terms of transport and storage conditions, the described components exceed the requirements of IEC 61131 Part 2. The following details apply to modules which are transported or stored in their original packaging.

Table A-3 Transport and storage conditions

Type of condition Permitted range Free fall (in transport packaging) ≤ 0.3 m Temperature between –40 °C and +70 °C Atmospheric pressure between 1080 and 660 hPa (corresponds to

altitudes of 1000 m to 3500 m) Relative humidity from 10 to 95 %, without condensation Sinusoidal oscillations complying with IEC 60068-2-6

5 - 9 Hz: 3.5 mm 9 - 150 Hz: 9.8 m/s2

Shock complying with IEC 60068-2-29 250 m/s2, 6 ms, 1000 shocks

A.2.5 Mechanical and climatic ambient conditions for operation

Operating conditions The described components are designed for use in a fixed, sheltered location. The operating conditions exceed the requirements of IEC 61131 Part 2. The described components meet the operating conditions of class 3C3 complying with DIN EN 60721 Part 2.

Operation with additional measures The described components must not be used at the following locations without additional measures: ● Locations with a high level of ionizing radiation ● Locations with complicated operating conditions; e g. due to

– dust – caustic vapors and gases – strong electrical or magnetic fields

● Plants which require special monitoring, e.g. – elevators – electrical systems in particularly hazard-prone areas

An additional measure may be fitting in a cabinet or enclosure.

Page 60: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Technical data A.2 General technical data

PN/PN coupler A-8 Installation and Operating manual, 08/2006, A5E00717043-01

Mechanical ambient conditions The mechanical ambient conditions for the described components are specified in the table below for sinusoidal vibrations.

Table A-4 Mechanical ambient conditions

Frequency range in Hz

continuously intermittently

10 ≤ f ≤ 58 0.0375 mm amplitude 0.075 mm amplitude 58 ≤ f ≤ 150 0.5 g constant acceleration 1 g constant acceleration

Reduction of vibrations If the described components are exposed to greater shocks or vibrations, you must reduce the acceleration or the amplitude by taking suitable measures. We recommend mounting the described components on damping material (e.g. on rubber-metal connections).

Tests for mechanical ambient conditions The following table provides information about the type and scope of tests for mechanical ambient conditions.

Table A-5 Tests for mechanical ambient conditions

Testing for ... Test standard Remarks Vibrations Vibration test with IEC

60068 Parts 2-6 (sinus) Type of vibration: Frequency cycles at a rate of change of 1 octave per minute. 10 Hz ≤ f ≤ 58 Hz, constant amplitude 0.075 mm 58 Hz ≤ f ≤ 150 Hz, constant acceleration 1 g Duration of vibration: 10 frequency cycles per axis in each of the 3 mutually perpendicular axes

Shock Shock test complying with IEC 60068 Parts 2-29

Type of shock: Half-sine Strength of shock: 15 g peak value, 11 ms duration Direction of shock: 3 shocks each in the +/- direction in each of the 3 mutually perpendicular axes

Page 61: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Technical data A.2 General technical data

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 A-9

Climatic ambient conditions The described components may be operated under the following climatic ambient conditions:

Table A-6 Climatic ambient conditions

Ambient conditions Permitted range Temperature: horizontal mounting all other mounting positions

from 0 to 60 °C from 0 to 40 °C

Relative humidity between 10 and 95 %, Atmospheric pressure from 1080 hPa to 795 hPa Contaminant concentration SO2: < 0.5 ppm;

RH < 60 %, no condensation H2S: < 0.1 ppm; RH < 60 %, no condensation

A.2.6 Specifications for insulation tests, safety class and degree of protection

Test voltages The insulation stability is tested with the following voltages during product testing:

Table A-7 Test voltages

Electric circuits with rated voltage Ue to other electric circuits or to earth

Test voltage

0 V < Ue ≤ 50 V DC 600 V, 1 s

Safety class Safety class I in compliance with IEC 60536; this means that a grounding terminal to the mounting rail is required!

Protection against foreign bodies and water Degree of protection IP 20 according to IEC 60529; that is protection against contact with standard probes. There is no protection from penetration by water.

Page 62: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Technical data A.2 General technical data

PN/PN coupler A-10 Installation and Operating manual, 08/2006, A5E00717043-01

A.2.7 Rated voltage

Rated voltage for operation The described components function with a rated voltage of 24 VDC. The tolerance range is DC 20.4 to 28.8 V.

Page 63: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 B-1

Order numbers and accessories BB.1 Order numbers and accessories

Overview

Table B-1 Order numbers for the PN/PN coupler

Components Order number PN/PN coupler 6ES7158-3AD00-0XA0 DIN rail 35 mm • 483 mm • 530 mm • 830 mm • 2000 mm

• 6ES5710-8MA11 • 6ES5710-8MA21 • 6ES5710-8MA31 • 6ES5710-8MA41

SIMATIC Micro Memory Cards • SIMATIC Micro Memory Card 64k • SIMATIC Micro Memory Card 128k • SIMATIC Micro Memory Card 512k • SIMATIC Micro Memory Card 2M • SIMATIC Micro Memory Card 4M • SIMATIC Micro Memory Card 8M

• 6ES7953-8LF11-0AA0 • 6ES7953-8LG11-0AA0 • 6ES7953-8LJ11-0AA0 • 6ES7953-8LL11-0AA0 • 6ES7953-8LM11-0AA0 • 6ES7953-8LP11-0AA0

Industrial Ethernet FC RJ45 Plug 90 (RJ45 cable connector for Industrial Ethernet with rugged metal housing and integrated insulation piercing contacts for connection to Industrial Ethernet FC installation lines; with 90° cable outlet • 1 item • 10 items • 50 items

• 6GK1901-1BB20-2AA0 • 6GK1901-1BB20-2AB0 • 6GK1901-1BB20-2AE0

Industrial Ethernet Fast Connect installation cables • Fast Connect standard cable • Fast Connect trailing cable • Fast Connect marine cable

• 6XV1840-2AH10 • 6XV1840-3AH10 • 6XV1840-4AH10

Industrial Ethernet Fast Connect stripping tool 6GK1901-1GA00 200 color-coding plates per packaging unit (10 star-shaped supports in packs of 20 items per color) • white • red • yellow • yellow-green • brown • blue • turquoise

• 6ES7193-4LA20-0AA0 • 6ES7193-4LD20-0AA0 • 6ES7193-4LB20-0AA0 • 6ES7193-4LC20-0AA0 • 6ES7193-4LG20-0AA0 • 6ES7193-4LF20-0AA0 • 6ES7193-4LH20-0AA0

Page 64: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Order numbers and accessories B.1 Order numbers and accessories

PN/PN coupler B-2 Installation and Operating manual, 08/2006, A5E00717043-01

Page 65: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 C-1

Dimensional drawings CC.1 PN/PN coupler dimensional drawing

Dimensional drawing PN/PN coupler dimensional drawing (dimensions in mm):

Page 66: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Dimensional drawings C.1 PN/PN coupler dimensional drawing

PN/PN coupler C-2 Installation and Operating manual, 08/2006, A5E00717043-01

Page 67: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 Glossary-1

Glossary

Bus A common transfer route connecting all nodes and having two defined ends.

Bus connector A physical connection between the bus node and the bus line.

Device names Before an IO device can be addressed by an IO controller, it must have a device name. This procedure was selected for PROFINET because names are easier to handle than complex IP addresses. Assignment of a device name for a specific IO device can be compared with the setting of the PROFIBUS address for a DP slave. An IO device does not have a device name upon delivery. Only once a device name has been assigned using the PG/PC, can an IO device be addressed by an IO controller, e.g. for the transmission of configuring data (including the IP address) during start-up or for the exchange of user data in cyclic mode.

Diagnostics Diagnostics is the detection, localization, classification, display and further evaluation of errors, faults, and messages. Diagnostics provides monitoring functions that run automatically while the system is in operation. This increases the availability of systems by reducing setup times and downtimes.

Earth The conductive earth whose electric potential can be set to zero at any point.

Electromagnetic compatibility (EMC) Electromagnetic compatibility is understood as the ability of a piece of electrical equipment to function perfectly in a specified environment without affecting its environmentin an impermissible way.

Page 68: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Glossary

PN/PN coupler Glossary-2 Installation and Operating manual, 08/2006, A5E00717043-01

Equipment, electrical All components, power circuits or parts of power circuits that are normally to be found in one single enclosure.

Firmware update Updating of firmware of interface module After (compatible) function extensions or after improvements to performance, the interface module can be updated to the latest firmware version.

Ground The conductive mass of earth, the electrical potential of which can be set equivalent to zero at all points. .

Grounding Grounding means connecting an electrically conductive part to a grounding system by means of the ground electrode.

GSD file The properties of a PROFINET device are described in a GSD file (General Station Descriptor), which contains all the information required for configuration. As with PROFIBUS, you can link a PROFINET device in STEP 7 by means of a GSD file. In PROFINET IO, the GSD file is always in XML format. The structure of the GSD file corresponds to ISO 15734, the worldwide standard for device descriptions. In the case of PROFIBUS the GSD file is available in the ASCII format (in compliance with the IEC 61784-1:2002 Ed1 CP 3/1 standard).

HW Config Part of STEP 7 for configuring hardware.

MAC address Each PROFINET device is assigned a worldwide unique device identifier in the factory. This 6-byte long device identifier is the MAC address. The MAC address consists of: ● 3-byte manufacturer ID and ● 3-byte device ID (sequential number). As a rule the MAC address is placed legibly on the front of the device e. g.: 08-00-06-6B-80-C0

Page 69: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Glossary

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 Glossary-3

Parameterization Parameterization (parameter assignment) is the transfer of slave parameters from master to the slave.

PELV Protective Extra Low Voltage = extra low voltage with safe isolation

Power supply unit A power supply unit supplies power to the field devices and the distributed process I/Os connected to them.

Process image The process image is part of the IO controller's system memory. The signal states of the input modules are transferred to the process-image inputs at the beginning of the cyclic program. At the end of the cyclic program, the process image of the outputs is transferred to the IO controller as signal status.

PROFINET Within the context of Totally Integrated Automation (TIA), PROFINET is the systematic continuation of the following systems: ● PROFIBUS DP, the established fieldbus ● Industrial Ethernet, the communication bus for the cell level Experiences from both systems have been and are being integrated in PROFINET. As an Ethernet-based automation standard of PROFIBUS International (formerly PROFIBUS user organization, registered society) PROFINET thus defines a communication, automation and engineering model valid for all manufacturers.

PROFINET components A PROFINET component includes all data of the hardware configuration, the parameters of the modules, and the associated user program. The PROFINET component comprises the following elements: ● Technological function

The (optional) technological (software) function includes the interface to other PROFINET components as interconnectable inputs and outputs.

● Device The device represents the physical automation device or field device, including the IO, sensors and actuators, mechanical system, and device firmware.

Page 70: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Glossary

PN/PN coupler Glossary-4 Installation and Operating manual, 08/2006, A5E00717043-01

PROFINET device A PROFINET device always has at least one Industrial Ethernet port. Additionally, a PROFINET device can have a PROFIBUS connection: as master with proxy functions. In exceptions, a PROFINET device can also have a several PROFIBUS connections (for example CP 5614).

PROFINET IO controller Device by means of which connected IO devices are addressed. In other words: The IO controller exchanges input and output signals with the assigned field devices. The IO controller is often the controller in which the automation program is executed.

PROFINET IO Within the context of PROFINET, PROFINET IO is a communication concept for implementing modular, distributed applications. PROFINET IO allows you to create automation solutions familiar from PROFIBUS. Implementation of PROFINET IO is carried out on the one hand via the PROFINET standard for automation devices and on the other by using the engineering tool STEP 7. This means that you have the same application layer in STEP 7 – regardless of whether you configure PROFINET devices or PROFIBUS devices. The programming of your user program is identical for PROFINET IO and PROFIBUS DP when you use the blocks and system status lists expanded for PROFINET IO.

PROFINET IO device Distributed field device which is assigned to one of the IO controllers (e.g. remote IO, valve terminals, frequency converter, switches).

Provider-consumer principle In a PROFINET IO both partners are independent providers in sending data, in contrast to PROFIBUS DP.

SELV Safety Extra Low Voltage of SELV is a voltage level ≤ AC 30 V/DC 60 V, which is produced by a safety transformer or accumulator.

SNMP SNMP (Simple Network Management Protocol) is the standardized protocol, for diagnosing and also configuring the Ethernet network infrastructure. In the office setting and in automation engineering, devices from many different manufacturers support SNMP on the Ethernet. SNMP-based applications can be operated on the same network in parallel to applications with PROFINET. The scope of the supported functions differs depending on the device type. For example, a switch has more functions than a CP 1616.

Page 71: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Glossary

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 Glossary-5

Switch PROFIBUS is a linear network. The communication nodes are connected with one another by means of a passive line - the bus. By contrast, the Industrial Ethernet consists of point-to-point connections: each communication node is directly connected to exactly one communication node. If a communication node is to be connected with several communication nodes, this communication node is connected to the port of an active network component - the switch. Additional communication nodes (including switches) can now be connected to the other ports of the switch. The connection between a communication node and the switch remains a point-to-point connection. A switch has the task of regenerating and distributing received signals. The switch "learns" the Ethernet address(es) of a connected PROFINET device or other switches and only forwards signals, which are destined for the connected PROFINET device or the connected switch. A switch has a specific number of ports. You connect at most one PROFINET device or additional switch to each port.

TN-S system In a TN-S system, the neutral conductor (N) and protective conductor (PE) are wired with separate insulation. The neutral conductor is connected to the grounded protective conductor at a central point, and only there. The protective conductor can be grounded any number of times.

Transmission rate The transmission rate specifies the number of bits transmitted per second.

Ungrounded Having no conductive connection to earth

User data flag Each IO module is assigned a value in the input or output data message; this value provides a statement on the quality of this user datum. For example, outputs of a specific module can be switched off by means of this without affecting other modules.

Page 72: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Glossary

PN/PN coupler Glossary-6 Installation and Operating manual, 08/2006, A5E00717043-01

Page 73: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 Index-1

Index

A Accessories, B-1 Additional support, iv Ambient conditions

climatic, A-9 mechanical, A-8 Operation, A-7 Transport and storage, A-7

Appearance, 1-3 Application, 1-1 Approval

CE, A-3 CSA, A-3 FM, A-4 UL, A-3

Approvals, iii Assembly, 2-1 Assembly rules, 2-1 Australian mark, A-4

B Basic knowledge, iii BF (LED), 6-1

C Cable, B-1 CE approval, A-3 CE mark, iii Changes compared to the previous version, iii Climatic ambient conditions, A-9 Color-coding plates, 2-2, B-1 Commissioning, 4-10 Components for assembly, 2-1 Configuration, 1-1

Example, 4-5 with STEP 7, 4-2

Configuring, 1-1 Overview, 4-1 with another configuring tool, 4-7 with GSD file, 4-7 with STEP 7, 4-2

Connections, 3-3 Contacts, iv CSA approval, A-3 C-Tick, iii

D DC 24 V power supply, 3-2 Degree of protection, A-9 Diagnostics, 6-5

after recovery of the IO device, 6-12 after STOP IO controller, 6-12 Example, 6-6

Dimensional drawing, C-1 DIN rail, 2-2, B-1 Disassembly, 2-2 Display elements, 1-3, 6-1 Disposal, iv disturbance variables

Pulse-shaped, A-5 sinusoidal, A-6

E Electrical isolation, 3-1 Electrical properties, 3-1 Electromagnetic compatibility, A-5 EMERGENCY STOP equipment, 3-2 Equipment

open, 2-1 Error displays, 6-1 Example of configuring, 1-2 Exchange

defective PN/PN coupler, 5-4

F FM approval, A-4 Function, 1-1

Page 74: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Index

PN/PN coupler Index-2 Installation and Operating manual, 08/2006, A5E00717043-01

G Grounding, 3-1 GSD file, 4-7 Guide through the manual, iv

I Identification data, 5-5 IEC 61131, A-4 industrial environments

Use in, A-4 Information landscape, iv Insulation test, A-9 Internet address, iv

L LEDs, 6-1 Lightning protection, 3-2 LINK (LED), 6-1

M Manual purpose, iii Manuals

Other important manuals, iv Marine type approval, A-4 Mechanical ambient conditions, A-8 Module replacement, 5-4 Mounting position, 2-1

N Newsletter, v

O ON (LED), 6-1 Operating conditions, A-7 Operation

Ungrounded, 3-1 Options, 6-5 Order numbers, B-1

P Parameterization, 1-1 PN/PN coupler

Assembling, 2-1 disassembling, 2-2 replace, 5-4

Power supply Connecting, 3-4 Two-way, 3-4

Principle of operation, 1-1 PROFINET IO

Cable, B-1 Connecting, 3-5 Standard, A-4

Properties, 3-1 Properties, 1-4 Purpose of manual, iii

R Radio interferences

Emission of, A-6 Rated voltage, A-10 Reading out the diagnostic data, 6-5 Recovery of the IO device

Diagnostics events triggered, 6-12 Recycling, iv residential areas

Use in, A-5 Response times, 5-1

Influencing factors, 5-1 Revisions, iii RX/TX (LED), 6-1

S Safety class, A-9 Scope, iii Service, v SF (LED), 6-1 SIMATIC Micro Memory Card, 5-2 SIMATIC Micro Memory Card

Slot, 1-3, 1-4 SIMATIC Micro Memory Card

Lifetime, 5-2 SIMATIC Micro Memory Card

Applicable SIMATIC Micro Memory Cards, 5-2 Standards, iv, A-3 Status and fault displays

LEDs, 6-2 Status displays, 6-1

Page 75: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Index

PN/PN coupler Installation and Operating manual, 08/2006, A5E00717043-01 Index-3

STEP 7, 6-5 STOP IO controller

Diagnostics events triggered, 6-12 Support on the Internet, v

T Technical data, A-1 Technical setup, 2-1 Test voltages, A-9 Training, v Two-way power supply, 3-4

U UL approval, A-3 Ungrounded operation, 3-1 Updating firmware

SIMATIC Micro Memory Card, 5-3 Use

in industrial environments, A-4 in residential areas, A-5

V Vibrations, A-8

Page 76: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Index

PN/PN coupler Index-4 Installation and Operating manual, 08/2006, A5E00717043-01

Page 77: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

s

Copyright © Siemens AG 2007

Siemens Aktiengesellschaft A5E01102629-01

SIMATIC

Product Information 03/2007

for the PN/PN Coupler Installation and Operating Manual

This product information contains important information on the PN/PN Coupler with the order number 6ES7158-3AD00-0XA0. The product information is included in the scope of delivery. In case of uncertainty, the contents of this product information take precedence over other information.

Page 78: Bus links PN/PN coupler - Siemens AG · Bus links PN/PN coupler Installation and Operating manual 08/2006 A5E00717043-02 The following supplement is part of this documentation:

Product Information PN/PN Coupler 2 A5E01102629-01

1 Supplement to the Manual

As of product version 2 of the PN/PN Coupler, the following memory modules can be used additionally to those mentioned in the Installation and Operating Manual of the PN/PN Coupler:

Component Order number

SIMATIC Micro Memory Cards • SIMATIC Micro Memory Card 64k • SIMATIC Micro Memory Card 128k • SIMATIC Micro Memory Card 512k • SIMATIC Micro Memory Card 2M • SIMATIC Micro Memory Card 4M • SIMATIC Micro Memory Card 8M

• 6ES7 953-8LF20-0AA0 • 6ES7 953-8LG20-0AA0 • 6ES7 953-8LJ20-0AA0 • 6ES7 953-8LL20-0AA0 • 6ES7 953-8LM20-0AA0 • 6ES7 953-8LP20-0AA0