attachment b - federal communications commission
TRANSCRIPT
531 W. Golf RoadT-Mobile Site CH46-433
Public Works Yard
Source: Mapquest.com Arlington Heights, IllinoisPhone: (847) 956-8589
Arbor Lane and Alan DriveAlgonquin, IL 60102
Site Location MapFigure 1
N
Site Location
Source: Concordia Wireless, Inc. Arlington Heights, IllinoisPhone: (847) 956-8589
Arbor Lane and Alan DriveAlgonquin, IL 60102
Site PlanFigure 2 531 W. Golf RoadT-Mobile Site CH46-433
Public Works Yard
Site Location
Figure 3
Source: www.topozone.com
531 W. Golf Road
Public Works Yard
Phone: (847) 956-8589
T-Mobile Site CH46-433
Algonquin, IL 60102Arbor Lane and Alan Drive Arlington Heights, Illinois
Topographic Map
N
Site Location
531 W. Golf RoadT-Mobile Site CH46-433
Public Works Yard
Source: FEMA Arlington Heights, IllinoisPhone: (847) 956-8589
Arbor Lane and Alan DriveAlgonquin, IL 60102
Flood Insurance Rate MapFigure 4
Site Location
SHEET DESCRIPTION
SHEET INDEX
NO.
VICINITY MAP
PROFESSIONAL LICENSURE
I CERTIFY THAT THESE DRAWINGS WERE PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND CONTROL AND TO THE BEST OF MY KNOWLEDGE AND BELIEF COMPLY WITH THE REQUIREMENTS OF THE GOVERNING LOCAL BUILDING CODE.
LICENSED PROFESSIONAL - STATE OF ILLINOIS
EXPIRES: SIGNED:
PROJECT INFORMATION PROJECT CONTACTS & UTILS
T-1
TITLE SHEET
REGIONAL MAP
DRIVING DIRECTIONS
DRIVING DIRECTIONS FROM 8550 W. BRYN MAWR AVE:
T- MOBILE8550 WEST BRYN MAWR AVESUITE 100CHICAGO, IL 60631PHONE NO: (773) 444-5400
SITE ADDRESS:
APPLICANTS:
SITE NAME:
W 88° 17' 37.64" (NAD 83)LONGITUDE:
PIN:
COUNTY:
SITE TYPE: MONOPOLE
SITE GROUND ELEVATION:
LATITUDE: N 42° 09' 10.34" (NAD 83)
731.8' AMSLPROP. OWNERCONTACT:
ENGINEERING& SURVEYINGCONTACT:
GM SADAT, PEPHONE: (847) 312-0830FAX: (847) 981-0803
TELEPHONE:
UTILITIES & CONTACT INFO
ELECTRICAL:
TITLE SHEETT-1
SP-1 SITE NOTES
SP-2 GENERAL NOTES AND SPECIFICATIONS
SITE GROUNDING PLANEG-1GROUNDING DETAILSEG-2
BTS INSTALLATION LAYOUT DETAILSUTILITY DETAILS
UTILITY DETAILS
ELECTRICAL SITE PLAN
EQUIPMENT PLATFORM & STRUCTURAL NOTES
ANTENNA DETAILS
SITE ELEVATION
ENLARGED SITE PLAN
E-4
E-3
E-2
E-1S-1
A-3
A-2
A-1
LOCATION OF T-MOBILE LEASE AREA & EASEMENTSLS-1
PPC CABINET DETAILS &
Site Number
Site Name
Site Address
(1) PRIMARY & (2) FUTURE S12000 T-MOBILE TELECOMMUNICATIONS EQUIPMENT CABINETS ON A
NEW STEEL PLATFORM AND (6) NEW ANTENNAS WITH (12) COAX CABLES
ON A NEW 120'-0" HIGH MONOPOLE(ANTENNA CENTER LINE= 120.0')
( LIGHTING ROD 124'-0")
A
No.
03/13/0690% REVIEW
Revision/Issue Date
PLATFORM REDESIGNISSUED FOR:MobileT
03-02-152-014, 03-03-152-016, 03-03-152-017, & 03-03-152-023
LEGAL DESCRIPTIONSLS-2
SITE LOCATION
GROUNDING DETAILSEG-3
LNA DETAILSA-4
VILLAGE OF ALGONQUIN2200 HARNISH DR.ALGONQUIN IL, 60102PHONE# (847) 658-2700
T- MOBILE APPROVALS
SITE ACQ.
OPS
RF
LANDLORD
CONST.
GROUNDING DETAILSEG-4
AT&T2000 W. AMERITECH CENTER SUITE, 4-C-10HOFFMAN STATES IL 601911-800-257-09021-800832-6328 (T-1 CONST.)
COMMONWEALTH EDISON 1700 SPENCER RD. JOLIET IL, 60433PHONE : 815- 740-1122
KEVIN HIPPNERPHONE: (773) 444-5400
T-MOBILE CONSTRUCTION MANAGER:
SITE ACQUISITION:
BRIAN M. BARRETTPHONE: (630) 440-6791
11-30-06
FENCING DETAILSA-5
KANE
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
CH46-433
PUBLIC WORKS RLALGONQUIN
ALGONQUIN ILARBOR LN. & ALAN DR.
PUBLIC WORKS RLALGONQUIN
ALGONQUIN ILARBOR LN & ALAN DR
1: Start out going SOUTHEAST on W BRYN MAWR AVE toward N CHESTER AVE. 0.2 miles Map 2: Turn LEFT onto N CUMBERLAND AVE / IL-171. 0.3 miles Map 3: Merge onto I-90 W toward O'HARE / ROCKFORD (Portions toll). 24.8 miles Map 4: Merge onto IL-31 N. 6.3 miles Map 5: Turn RIGHT onto ARBOR LN. <0.1 miles Map 6: End at Alan Dr & Arbor Ln Total Est. Time: 41 minutes Total Est. Distance: 31.97 miles
CIVIL DETAILSA-6
SILT FENCE DETAILA-7
B 06/19/06PERMIT REDESIGN
Initial
R.A.H
CONTRACTOR SHALL HAVE THE SITE MANNED WITH A SUPERVISOR AND CREW FOR THE FULL 28 DAYS OF THE BUILD.GC SHALL CONTACT THE A&E FIRM PRIOR TO BIDWALK AND CONSTRUCTION START TO CONFIRM THAT DRAWINGS ARE THE MOST RECENT SET.
R
U
8109N
S
ET0 F I
AT
CEIL
PACYATH DD E
ENS D A
LLINIO
S
CE
AI KS A.
TTI
CH
BILL OF MATERIALS (PROVIDED BY T-MOBILE)BOM-1
C 07/11/06PLATFORM REDESIGN R.A.H
SITE NOTES
COAXIAL CABLE
CHAIN LINK FENCING
OVERHEAD ELECTRIC/TELEPHONECONDUCTORS
BELOW GRADE ELECTRICAL CONDUIT
BELOW GRADE TELEPHONE CONDUIT
GROUND CONDUCTOR
PROPERTY/LEASE LINE
GROUT OR PLASTER
WORK POINT
MATCH LINE
CENTERLINE
WOOD BLOCKING
WOOD CONT.
(E) MASONRY
X-X
X-XX
X
X
1
T
DETAIL REFERENCE
ELEVATION REFERENCEOE/OT
X
A
GRID REFERENCE
SET POINT
REVISION
FND. MONUMENT
SPOT ELEVATION
TELEPHONE BOX
LIGHT POLE
UE
UT
STEEL
E
GROUND BUS BAR
GROUND ACCESS WELL
ELECTRIC BOX
CAD WELD
MECHANICAL GRND. CONN.
GROUND ROD
EXISTING ANTENNA
NEW ANTENNA
CONCRETE
PLYWOOD
SAND
GRAVEL
EARTH
(E) BRICK
T.O.P.
U.N.O.
T.O.W.T.O.S.
T.O.F.
T.O.A.
STRUC.TEMP.
T.O.C.
REQ'D.
SPEC.
P.S.F.
REINF.
RAD.(R)
NO.(#)N.T.S.
OPNG.
MECH.
LB.(#)
MDCMC
CLR. CLEAR PCS
F.G. FINISH GRADE
GROWTH (CABINET)
GLOBAL POSITIONING SYSTEM
GALVANIZE(D)GROUND FAULT CIRCUIT INTERRUPTER
FOUNDATION
FINISH SURFACE
FACE OF CONCRETE
FACE OF STUDFACE OF WALL
FACE OF MASONRY
FOOT(FEET)
GND.HGR.HT.
G.F.I.GPS
GI.
HEIGHT
GROUNDHANGER
F.O.S.
FT.(')FTG.
GA.G.
F.O.W.F.S.
FDN.
F.O.M.F.O.C.
FLR.FIN.
GAUGE
FOOTING
FLOORFINISH(ED)
WAP.
LCLP
WT.WCS
U.G.
V.I.F.WW/
U.L.
TYP.
FINISH FLOORFABRICATION(OR)
ELECTRICAL METALLIC TUBING
DEPARTMENT
ELECTRICAL
DRAWING(S)
CONSTRUCTIONCONTINUOUS
CONNECTION(OR)
EQ.
EXT.FAB.F.F.
EXIST.(E)EXP.
ELEV.EMT.ENG.
ELEC.
EA.EL.
EQUALEXPANSION
EXTERIOREXISTING
ENGINEER
EACH
ELEVATOR
ELEVATION
DWL.DWG.DIM.DIAG.
DEPT.DIA.
CONN.CONST.CONT.DBL.
CONC.COL.
DOWEL(S)
DIAMETER
DIMENSIONDIAGONAL
DOUBLE
CONCRETECOLUMN
RGS.
THK.
STL.STD.S.S.SQ.
SCH.SHT.SIM.
PWR.
REF.
QTY.
P.T.P.S.I.
PRCPLY.
BARE TINNED COPPER WIRE
BACK-UP CABINET
CANTILEVER(ED)CAST IN PLACE
BOTTOM OF FOOTING
AMERICAN WIRE GAUGE
ABOVE FINISHED FLOOR
APPROXIMATE(LY)ARCHITECT(URAL)
ABOVE FINISHED GRADE
AWG.
B.O.F.
CANT.C.I.P.CLG.
B/UCAB.
BLKG.
BTCW.BM.
BLDG.BLK.
CEILING
CABINET
BLOCK
BEAMBLOCKING
BUILDING
ARCH.APPRX.ANT.
ALUM.A.F.G.
ALT.
ADD'LA.F.F.
ABV.
ANTENNA
ALUMINUMALTERNATE
ADDITIONALABOVE
O.C.
MTL.(N)
MFR.
MISC.MIN.
MAX.MAS.
L.F.L.
ICGB.
INT.IN.(")
PERSONAL COMMUNICATION SERVICES
TOP OF CURB
WIRELESS COMMUNICATION SERVICEWIRED ACCESSED POINT
CENTERLINEPLATE
WEIGHT.
UNLESS NOTED OTHERWISEUNDERWRITERS LABORATORY
WIDE(WIDTH)
TOP OF PLATE (PARAPET)
VERIFY IN FIELD
TOP OF WALLTOP OF STEEL
UNDER GROUND
TOP OF FOUNDATION
WITH
TYPICAL
RIGID GALVANIZED STEEL
TOP OF ANTENNATHICK(NESS)TEMPORARYSTRUCTURAL
STAINLESS STEEL
SPECIFICATION(S)
STANDARD
SCHEDULE
STEEL
SQUARE
SIMILARSHEET
POUNDS PER SQUARE FOOTPOUNDS PER SQUARE INCH
REQUIRED
POWER (CABINET)
REINFORCEMENT(ING)
PRESSURE TREATED
REFERENCE
PRIMARY RADIO CABINET
QUANTITYRADIUS
PLYWOOD
ISOLATED COPPER GROUND BUS
CONSTRUCTION MANAGEMENT
NOT TO SCALEON CENTER
& CONTRACTING
MISCELLANEOUS
MANUFACTURERMECHANICAL
OPENING
NUMBER
METALNEW
MINIMUM
POUND(S)
METRICOM DESIGNATED
LONG(ITUDINAL)LINEAR FEET (FOOT)
MASONRYMAXIMUM
INCH(ES)INTERIOR
PROCTOR DENSITY.
TO 1 VERTICAL SHALL BE PROPERLY BENCHED INTO THE EXISTING SLOPE AS DIRECTED14. ANY FILLS PLACED ON EXISTING SLOPES THAT ARE STEEPER THAN 10 HORIZONTAL
EXCEED THAT WHICH CAN BE PROPERLY COMPACTED THROUGHOUT ITS ENTIRE DEPTH13. ALL FILL SHALL BE PLACED IN UNIFORM LIFTS. THE LIFTS THICKNESS SHOULD NOT
12. NEW GRADES NOT IN BUILDING AND DRIVEWAY IMPROVEMENT AREA TO BE ACHIEVED
ETC., SHALL BE PROPERLY LAID BACK OR BRACED IN ACCORDANCE WITH CORRECT
BY A GEOTECHNICAL ENGINEER.
WITH THE EQUIPMENT AVAILABLE.
BY FILLING WITH APPROVED CLEAN FILL AND COMPACTED TO 95% OF STANDARD
MAXIMUM STANDARD PROCTOR DRY DENSITY.11. STRUCTURAL FILLS SUPPORTING PAVEMENTS SHALL BE COMPACTED TO 100% OF
OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) REQUIREMENTS.
10. ALL EXCAVATIONS FOR THE INSTALLATION OF FOUNDATIONS, UTILITIES,
SLOPE AND IS TO FEATHER INTO EXISTING GRADES AT THE GRADING LIMITS.9. GRADING OF THE SITE WORK AREA IS TO BE SMOOTH AND CONTINUOUS IN
STIPULATED BY THE CODE ENFORCEMENT OFFICIAL HAVING JURISDICTION.AT LEAST TWO WORKING DAYS PRIOR TO THE COMMENCEMENT OF WORK OR AS
8. THE BUILDING DEPARTMENT ISSUING THE BUILDING PERMIT SHALL BE NOTIFIED
FULL DAYS PRIOR TO COMMENCEMENT OF CONSTRUCTION.
3. DO NOT SCALE BUILDING DIMENSIONS FROM DRAWINGS.
AND ISSUED TO ARCHITECT/ENGINEER AT COMPLETION OF PROJECT.BE ACCURATELY NOTED AND PLACED ON AS-CONSTRUCTED DRAWINGSLOCATION AND TYPE OF ANY UNDERGROUND UTILITIES OR IMPROVEMENTS SHALLRETURNED TO ITS ORIGINAL CONDITION PRIOR TO COMPLETION OF WORK. SIZE,
4. ANY DRAIN AND/OR FIELD TILE ENCOUNTERED DURING CONSTRUCTION SHALL BE
2. DO NOT EXCAVATE OR DISTURB BEYOND THE PROPERTY LINES OR LEASE LINES,
1. REPRESENTATIVES OF THE OWNER MUST BE NOTIFIED AT LEAST TWO
UNLESS OTHERWISE NOTED.
REMOVING OR ADJUSTING EXISTING UTILITIES.
REMOVAL OR ADJUSTMENT. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING
6. CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES BOTH HORIZONTALLY AND
DETAILED INFORMATION RELATIVE TO WORKING SCHEDULES AND METHODS OFCONSTRUCTION. CONTRACTOR SHALL ALSO OBTAIN FROM EACH UTILITY COMPANYEXACT LOCATION OF ALL EXISTING UTILITIES AND FACILITIES PRIOR TO START OF
ON PLANS HAVE BEEN PLOTTED FROM AVAILABLE RECORDS. THE ARCHITECT/ENGINEER
ACCURACY OF THE INFORMATION SHOWN ON THE PLANS OR THE MANNER OF THEIRAND OWNER ASSUME NO RESPONSIBILITY WHATSOEVER AS TO THE SUFFICIENCY OR
5. ALL EXISTING UTILITIES, FACILITIES, CONDITIONS, AND THEIR DIMENSIONS SHOWN
DISTURBED BY CONSTRUCTION SHALL BE ADJUSTED TO FINISH ELEVATIONS PRIOR7. ALL NEW AND EXISTING UTILITY STRUCTURES ON SITE AND IN AREAS TO BE
FOR UTILITY LOCATIONS 48 HOURS PRIOR TO START OF CONSTRUCTION.AND EXPENSE. CONTRACTOR SHALL CALL OUPS AT (800) - 362-2764INSTRUCTION MEANS CONTRACTOR WILL HAVE WORKED AT HIS/HER OWN RISKCORRECTED BY THE ARCHITECT/ENGINEER. FAILURE TO SECURE SUCHWORK SHALL BE PERFORMED UNTIL THE DISCREPANCY IS CHECKED ANDTHE ARCHITECT/ENGINEER FOR RESOLUTION AND INSTRUCTION, AND NO FURTHERAS TO THE INTERPRETATION OF PLANS SHOULD BE IMMEDIATELY REPORTED TOVERTICALLY PRIOR TO START OF CONSTRUCTION. ANY DISCREPANCIES OR DOUBTS
TO FINAL INSPECTION OF WORK.
IMPROVEMENTS SHALL BE PROTECTED.17. ALL TREES AND SHRUBS WHICH ARE NOT IN DIRECT CONFLICT WITH THE
MATERIALS COLLECTED DURING CLEANING OPERATIONS SHALL BE DISPOSED OFPAPERS, TRASH, WEEDS, BRUSH OR ANY OTHER DEPOSITS WILL REMAIN. ALL
16. CONTRACTOR SHALL CLEAN ENTIRE SITE AFTER CONSTRUCTION SO THAT NO
ACHIEVING FINISH GRADE BY ADDING 6" OF 3/4" CRUSHED STONE-NO FINES.WITH 6 MIL. VISQUENE (1' OVERLAP AT SEAMS) FOR WEED SUPPRESSION, THENCLEAN FILL TO A DENSITY OF 90% OF STANDARD PROCTOR COVERING THE AREA
15. THE GRADES WITHIN THE FENCED-IN AREA ARE TO BE ACHIEVED BY COMPACTING
OFF-SITE.
SP-1GENERAL NOTESSCALE: NTS2
PROJECT ABBREVIATIONSSCALE: NTS3PROJECT SYMBOLS
SCALE: NTS1
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
ONTAE I
expires 11-30-2006
F0 LLI
Y8109
E
A
ICL
PAC
TS
HT DAD
ESNE
D
CE
ANI K
SI
A.US
TTIHR C
SP-2
GENERAL NOTES& SPECIFICATIONS
A.
C.
B.
A.
B. A.
F.
G.
E.
D.
A.
B.
C.
FALL PROTECTIONCONFINED SPACEELECTRICAL SAFETYTRENCHING AND EXCAVATION
SHELTER (GROUND BUILD/CO-LOCATE ONLY)AC/TELCO INTERFACE BOX(PPC)
TOWERS, MONOPOLE
BTS EQUIPMENT FRAME (PLATFORM) AND ICEBRIDGE
HANGERS HOISTING GRIPSBTS EQUIPMENT
GENERATORS & LIQUID PROPANE TANKANTENNA STANDARD BRACKETS, FRAMES, AND PIPES
FOR MOUNTING.
ANTENNAS (INSTALLED BY OTHERS)TRANSMISSION LINETRANSMISSION LINE JUMPERSTRANSMISSION LINE CONNECTORS WITHWEATHERPROOFING KITSTRANSMISSION LINE GROUND KITS
TOWER LIGHTING
ICE BRIDGE (CABLE TRAY WITH COVER) (GROUND BUILD/CO-LOCATE ONLY, GC TO FURNISH AND INSTALL FOR ROOFTOP INSTALLATION)
6.CONTRACTOR SHALL ESTABLISH GRADE AND LINE STAKES PRIOR TO CONSTRUCTION.CONTRACTOR IS RESPONSIBLE FOR LAYOUT AND CONSTRUCTION STAKING.
6. PROTECTION
2. ALL COAXIAL CABLE GROUNDING KITS ARE TO BE INSTALLED ON STRAIGHTRUNS OF COAXIAL CABLE (NOT WITHIN BENDS).
ANTENNA AND COAXIAL CABLE GROUNDING:1. ALL EXTERIOR #6 GREEN GROUND WIRE "DAISY CHAIN" CONNECTIONS
ARE TO BE WEATHER SEALED WITH RFS CONNECTOR/SPLICEWEATHERPROOFING KIT #221213 OR EQUAL.
LOCATION UNLESS OTHERWISE STATED. TERMINATE ALL COAXIAL CABLE THREE (3) FEET IN EXCESS OF ENTRY PORT
INSTALL COAXIAL CABLES AND TERMINATING BETWEEN ANTENNAS AND EQUIPMENTPER MANUFACTURER'S RECOMMENDATIONS. WEATHERPROOF ALL CONNECTORSBETWEEN THE ANTENNA AND EQUIPMENT PER MANUFACTURER'S REQUIREMENTS.
AND SUBMITTED WITHIN ONE WEEK OF WORK COMPLETION.SHALL BE PERFORMED BY AN INDEPENDENT TESTING SERVICE AND BE BOUNDFOR ANTENNA AND HELIAX COAXIAL CABLE SYSTEMS" DATED 10/5/93. TESTING
CONTRACTOR SHALL PROVIDE FOUR (4) SETS OF SWEEP TESTS USING ANRITZU-PACKARD 8713B RF SCALAR NETWORK ANALYZER. SUBMIT FREQUENCY DOMAINREFLECTOMETER(FDR) TESTS RESULTS TO THE PROJECT MANAGER. SWEEP TESTSSHALL BE AS PER ATTACHED RFS "MINIMUM FIELD TESTING RECOMMENDED
PROVIDE PRINTOUT OF THAT TEST.
INSTALL FURNISHED GALVANIZED STEEL OR ALUMINUM WAVEGUIDE AND
INSTALL GALVANIZED STEEL ANTENNA MOUNTS AS INDICATED ON DRAWINGS.
INSTALL ANTENNAS AS INDICATED ON DRAWINGS AND T-MOBILE SPECIFICATIONS.
CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF PERSONNEL ANDPROPERTY.
CONTRACTOR IN TERMS OF COORDINATION AND SITE ACCESS. ERECTION SUB-
ANTENNA INSTALLATION
1.
DIVISION 13 - SPECIAL CONSTRUCTION
ANTENNAS AND COAXIAL CABLES ARE FURNISHED BY T-MOBILE UNDER ASEPARATE CONTRACT. THE CONTRACTOR SHALL ASSIST ANTENNA INSTALLATION
WORK INCLUDED:
ZINC BASED PAINT. COLOR TO MATCH THE GALVANIZING PROCESS.
UPON COMPLETION OF ERECTION INSPECT ALL GALVANIZED STEELAND PAINT ANY FIELD CUTS, WELDS, OR GALVANIZED BREAKS WITH
FIELD WELDING SHALL BE DONE AS PER AWSD1.1 REQUIREMENTS VISUALINSPECTION IS ACCEPTABLE.
USED IN THE SUBMERGED ARC PROCESS SHALL CONFORM TO AISC SPECIFICATIONS.
WELDING ELECTRODES FOR MANUAL SHIELDED METAL ARC WELDING SHALL CONFORM TO ASTM A-233, E70 SERIES. BARE ELECTRODES AND GRANULAR FLUX
REQUESTED.
5.ALL WELDING SHALL BE DONE BY CERTIFIED WELDERS. CERTIFICATION DOCUMENTS
WELDING
SHALL BE MADE AVAILABLE FOR ENGINEER'S AND/OR OWNER'S REVIEW IF
SPRAYING DEVICES.
SUCCESSFUL CURING SHALL BE OBTAINED BY USE OF AN AMPLE WATER SUPPLYUNDER PRESSURE IN PIPES, WITH ALL NECESSARY APPLIANCES OF SPRINKLERS, AND
AND FREE FROM ACID, ALKALI, SALTS, OIL SEDIMENT, AND ORGANIC MATTER.
C. ALL CONCRETE SHALL BE WATER CURED BY CONTINOUS (NOT PERIODIC) FINEMIST SPRAYING OR SPRINKLING ALL EXPOSED SURFACES. WATER SHALL BE CLEAN
B. CONCRETE SHALL BE MAINTAINED WITH MINIMAL MOISTURE LOSS AT RELATIVELYCONSTANT TEMPERATURE FOR A PERIOD NECESSARY FOR HYDRATION OF CEMENT AND HARDENING OF CONCRETE.
10. PROTECTION
MECHANICAL INJURY. FINISHED WORK SHALL BE PROTECTED.FROM PREMATURE DRYING, EXCESSIVELY HOT OR COLD TEMPERATURES, AND
A. IMMEDIATELY AFTER PLACEMENT, THE CONTRACTOR SHALL PROTECT THE CONCRETE
B. PLACEMENT OF CONCRETE SHALL BE IN ACCORDANCE WITH ACI 301.
AND GIVEN APPROVAL TO START PLACEMENT IN WRITING.
THE WORK AS SPECIFIED. CONCRETE MAY NOT BE ORDERED FOR PLACEMENT UNTIL ALL ITEMS HAVE BEEN APPROVED AND T-MOBILE HAS PERFORMED A FINAL INSPECTION
BEEN APPROVED, AND UNTIL FACILITIES ACCEPTABLE TO THE T-MOBILEREPRESENTATIVE HAVE BEEN PROVIDED AND MADE READY FOR ACCOMPLISHMENT OF
A. THE ENGINEER SHALL BE NOTIFIED NOT LESS THAT 24 HOURS IN ADVANCE OF
CONCRETE SHALL BE PERFORMED ONLY IN THE PRESENCE OF THE ENGINEER.CONCRETE PLACEMENT, UNLESS INSPECTION IS WAIVED IN EACH CASE, PLACING OF
CONCRETE SHALL NOT BE PLACED UNTIL ALL FORMWORK, EMBEDDED PARTS, STEEL REINFORCEMENT, FOUNDATION SURFACES AND JOINTS INVOLVED IN THE PLACING HAVE
9. PLACING CONCRETE
C. ONE SLUMP TEST SHALL BE TAKEN FOR EACH SET OF TEST CYLINDERS TAKEN.
B. ONE ADDITIONAL TEST CYLINDER SHALL BE TAKEN DURING COLD WEATHER ANDCURED ON SITE UNDER SAME CONDITIONS AS CONCRETE IT REPRESENTS.
A. FIVE CONCRETE TEST CYLINDERS SHALL BE TAKEN OF THE TOWER PIER FOUNDATION.TWO SHALL BE TESTED @ THREE DAYS, TWO @ TWENTY-EIGHT DAYS. THE FIFTHCYLINDER SHALL BE KEPT SEPARATELY, IF REQUIRED TO BE USED IN THE FUTURE.
IS DISCOVERED NOR SHALL IT OBLIGATE THE ENGINEER FOR FINAL ACCEPTANCE.
8. TESTSCONCRETE MATERIALS AND OPERATIONS SHALL BE TESTED AND INSPECTED BY THE ENGINEER AS THE WORK PROGRESSES. FAILURE TO DETECT ANY DEFECTIVE WORKOR MATERIAL SHALL NOT IN ANY WAY PREVENT LATER REJECTION WHEN SUCH DEFECT
15. CONTRACTOR SHALL SUBMIT AT THE END OF THE PROJECT A COMPLETE SET OFAS BUILT DRAWINGS TO T-MOBILE'S ' PROJECT ENGINEER.
GENERAL NOTES (CONT'D):
1.
2.
3.
4.
5.
6.
7.
4.
3.
2.
1.
5.
4.
3.
2.
9.
8.
7.
6.
5.
4.
3. 1.
14.
13.
12.
11.
10.
2.
1. DIVISION 5 - STRUCTURAL STEEL:
DIVISION 2 - SITE WORK:
A. ASTM A36, GRADE 36; ROLLED STEEL, RODS, PLATES,
B. ASTM A325 BOLTS, BEARING TYPEC. ALL STEEL SHALL BE HOT-DIP GALVANIZED IN ACCORDANCE WITH ASTM A123.
U-BOLTS AND ANCHOR BOLTS.
LATEST AISC MANUAL OF STEEL CONSTRUCTION (ASD), AWS D1.1, AND THE DETAIL, FABRICATE AND ERECT STRUCTURAL STEEL IN ACCORDANCE WITH THE
BASIC BUILDING CODE. STRUCTURAL STEEL SHALL BE AS FOLLOWS:
THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND/OR BRACING WHEREREQUIRED DURING CONSTRUCTION UNTIL ALL CONNECTIONS ARE COMPLETE.
A FEW IMPACTS OF A IMPACT WRENCHTHE FULL EFFORT OF A PERSON USING A SPUD WRENCH.
ENGINEER, AND T- MOBILE PROJECT MANAGER IN WRITING
TIGHTEN HIGH STRENGTH BOLTS TO A SNUG TIGHT CONDITION WHERE ALL PLIESIN A JOINT ARE IN FIRM CONTACT BY EITHER
ANY FIELD CHANGES OR SUBSTITUTIONS SHALL HAVE PRIOR APPROVAL FROM THE
OF ENGINEERING.NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVALAND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL
WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVEDALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES,
SLOPE, FERTILIZED, SEEDED, AND COVERED WITH MULCH COVERED BY THE BUILDING OR DRIVEWAY, SHALL BE GRADED TO A UNIFORMTHE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT
CONSTRUCTION.CONSTRUCTION. EROSION CONTROL MEASURES, AS REQUIRED DURINGCONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING
DIVISION 3 - CONCRETE:
C172, ASTM C31 AND ASTM C39 UNLESS OTHERWISE NOTED.AMERICAN SOCIETY FOR TESTING AND MATERIALS METHODS STANDARDS ASTM4000 PSI AT 28 DAYS WHEN TESTED IN ACCORDANCE WITH THEMINIMUM ALLOWABLE CONCRETE COMPRESSIVE STRENGTH SHALL BE
WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185.
CHAMFER ALL EXPOSED EDGES OF CONCRETE 3/4".UNLESS OTHERWISE NOTED.
DETAILING REINFORCED CONCRETE STRUCTURES (ACI STD-315 LATEST EDITION).DETAILING SHALL BE IN ACCORDANCE WITH MANUAL OF STANDARD PRACTICE OF
OF 60,000 PSI (40,000 PSI GRADE MAY BE USED FOR TIES & STIRRUPS).
REBARS SHALL BE ASTM A-615 DEFORMED TYPE WITH MINIMUM YIELD STRENGTH
SPECIFICATION FOR STRUCTURAL CONCRETE.REQUIREMENTS FOR REINFORCED CONCRETE AND (ACI 301) STANDARDEDITION OF THE AMERICAN CONCRETE INSTITUTE (ACI 318) BUILDING CODEALL CONCRETE CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE LATEST
OBTAIN SLUMP OVER 3-INCHES.CONTROL TOTAL AIR CONTENT, WATER REDUCING ADMIXTURE PERMITTED TOPERCENT TO 7 PERCENT BY VOLUME. AIR ENTRAINING ADMIXTURE REQUIRED TOAGGREGATE, SLUMP RANGE 3 INCHES TO 5 INCHES, TOTAL AIR CONTENT 4CONCRETE MINIMUM CEMENT CONTENT FOR 1-INCH MAXIMUM SIZECONCRETE FOR ALL FOUNDATIONS: 540 LBS PER CUBIC YARD OF
#5 BAR AND SMALLER ... 1-1/2"#6 THROUGH #18 ... 2"
EXPOSED TO EARTH OR WEATHER:CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH ... 3"MINIMUM COVER (INCHES)
D.C.B.A.
WORKING CREW. THIS WILL INCLUDE BUT NOT LIMITED TO:NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THEBE USED BY THE CONTRACTOR WHEN EXCAVATING OR PIER DRILLING AROUND ORRELOCATED AS DIRECTED BY THE PROJECT MANAGER. EXTREME CAUTION SHOULDWHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BEWHERE ENCOUNTERED IN THE WORK SHALL BE PROTECTED AT ALL TIMES, ANDALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES
LEGAL MANNER.CONTAMINATED OR DANGEROUS TRASH AND DEBRIS, AND DISPOSE OF IN AEXCAVATED MATERIAL INCLUDING MATERIAL CLASSIFIED UNSATISFACTORY,REMOVE FROM SITE/OWNER'S PROPERTY ALL WASTE MATERIALS, UNUSED
THE CONTRACTOR SHALL CALL UTILITIES PRIOR TO THE START OF CONSTRUCTION.
SHALL BE PROVIDED, EXCEPT AS NOTED ON DRAWINGS.DRAWINGS. THE FOLLOWING MINIMUM COVER (INCHES) FOR REINFORCEMENTIN POSITION. LOCATION OF REINFORCEMENT SHALL BE INDICATED ON THEREINFORCING STEEL SHALL BE ACCURATELY PLACED AND ADEQUATELY SECURED
AFFECTED UTILITIES.RELATIVE TO WORKING SCHEDULES AND METHODS OF REMOVING OR ADJUSTINGSHALL ALSO OBTAIN FROM EACH UTILITY COMPANY DETAILED INFORMATIONSAID UTILITIES AND FACILITIES PRIOR TO START OF CONSTRUCTION. CONTRACTORCONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING EXACT LOCATION OF ALLON THE PLANS OR THE MANNER OF THEIR REMOVAL OR ADJUSTMENT. WHATEVER AS TO THE SUFFICIENCY OR ACCURACY OF THE INFORMATION SHOWNARCHITECT/ENGINEER AND OWNER (T-MOBILE) ASSUME NO RESPONSIBILITY
ON PLANS HAVE BEEN PLOTTED FROM AVAILABLE RECORDS. THEALL EXISTING UTILITIES, FACILITIES, CONDITIONS, AND THEIR DIMENSIONS SHOWN
EXPENSE.
INSTRUCTION MEANS CONTRACTOR WILL HAVE WORKED AT HIS OWN RISK ANDCORRECTED BY THE ARCHITECT/ENGINEER. FAILURE TO SECURE SUCH
NO FURTHER WORK SHALL BE PERFORMED UNTIL DISCREPANCY IS CHECKED ANDREPORTED TO THE PROJECT MANAGER FOR RESOLUTION AND INSTRUCTION, ANDDOUBTS AS TO THE INTERPRETATION OF PLANS SHOULD BE IMMEDIATELYAND VERTICALLY PRIOR TO START OF CONSTRUCTION. ANY DISCREPANCIES ORCONTRACTOR SHALL FIELD VERIFY ALL EXISTING UTILITIES BOTH HORIZONTALLY
JURISDICTION OVER THIS LOCATION.LOCAL GAS, ELECTRIC, TELEPHONE, AND ANY OTHER UTILITY COMPANIES HAVINGALL SITE WORK SHALL BE CAREFULLY COORDINATED BY THE CONTRACTOR WITH
COORDINATED WITH THE BUILDING/PROPERTY OWNER.BUILDING/PROPERTY OWNER AND ANY SUCH SHUTDOWN TIME SHALL BE
SHALL BE MADE WITH A MINIMUM AMOUNT OF INCONVENIENCE TO THESUCH INTERRUPTION, AT LEAST 72 HOURS IN ADVANCE. ANY INTERRUPTIONSECURE PERMISSION IN WRITING FROM THE BUILDING/PROPERTY OWNER FOR
NECESSARY TO INTERRUPT ANY SERVICE OR UTILITY, THE CONTRACTOR SHALLUTILITIES OF THE BUILDING/SITE WITHOUT INTERRUPTION. SHOULD IT BE
DURING CONSTRUCTION, THE CONTRACTOR SHALL AT ALL TIMES MAINTAIN THE
DISPOSED OF OFF-SITE BY THE CONTRACTOR.MATERIALS COLLECTED DURING CLEANING OPERATIONS SHALL BE PROPERLYPAPERS, TRASH, DEBRIS, WEEDS, BRUSH, OR ANY OTHER DEPOSITS REMAIN. ALLCONTRACTORS SHALL CLEAN ENTIRE SITE AFTER CONSTRUCTION SUCH THAT NO
CONSTRUCTION. CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURINGCONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING
LABEL.REQUIREMENTS OF THE UNDERWRITERS' LABORATORIES (U.L.) AND BEAR THE U.L.(EXCEPT WHERE OTHERWISE NOTED) AND SHALL COMPLY WITH THE
ELECTRICAL EQUIPMENT PROVIDED UNDER THIS CONTRACT SHALL BE NEWAPPLICABLE FEDERAL, STATE, AND LOCAL LAWS AND ORDINANCES. ALLELECTRICAL CODE (NEC). NATIONAL ELECTRICAL SAFETY CODE, OSHA, AND ALL
OF THE LATEST EDITIONS AND INTERIM AMENDMENTS OF THE NATIONALALL WORK, MATERIAL, AND EQUIPMENT SHALL COMPLY WITH ALL REQUIREMENTS
CONTRACTOR AT NO COST TO THE OWNER.DUE TO DEFECTS IN MATERIALS OR WORKMANSHIP SHALL BE CORRECTED BY THEACCEPTANCE, UNLESS NOTED OTHERWISE. ANY FAILURE OF EQUIPMENT OR WORKWORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL
DOCUMENTS SHALL BE GUARANTEED AGAINST DEFECTS IN MATERIALS ORALL EQUIPMENT FURNISHED AND WORK PERFORMED UNDER THE CONTRACT
COST TO THE OWNER OR HIS ARCHITECT/ENGINEER.
REQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE CONTRACTOR AT NOEQUIPMENT SHALL BE REPLACED WITH EQUIPMENT CONFORMING TO THETHE CONTRACT DOCUMENTS, EITHER BEFORE OR AFTER INSTALLATION AND THEEQUIPMENT OR MATERIALS WHICH, IN HIS OPINION ARE NOT IN COMPLIANCE WITHT-MOBILE OR HIS ARCHITECT/ENGINEER RESERVES THE RIGHT TO REJECT ANY
ITS ORIGINAL CONDITION AT HIS OWN EXPENSE.AFTER IT HAS BEEN INSPECTED, THE CONTRACTOR SHALL RESTORE THE WORK TOINSPECTION AND TEST SHALL BE UNCOVERED AT THE CONTRACTOR'S EXPENSE;
AUTHORITIES. ANY WORK THAT IS ENCLOSED OR COVERED UP BEFORE SUCHCOVERED UP OR ENCLOSED UNTIL IT HAS BEEN INSPECTED BY THE GOVERNINGTHE CONTRACTOR SHALL NOT ALLOW OR CAUSE ANY OF THE WORK TO BE
DIMENSIONS WHICH AFFECT THE NEW CONSTRUCTION.EXISTING STRUCTURES DURING CONSTRUCTION. FIELD VERIFY ALL EXISTINGREQUIRED. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE PROTECTION OF ANYTHE CONTRACTOR SHALL SUPPORT, BRACE AND SECURE EXISTING STRUCTURE AS
CONTRACTOR TO FURNISH AND INSTALL THE FOLLOWING:
AWARDING THE CONTRACT.THE BUILDING PERMIT WILL BE ADDED TO THE LUMP SUM BID PRIOR TORESPONSIBLE FOR PICKUP AND PAYMENT OF REQUIRED PERMITS. THE COST OFIT IS THE POSITION OF T-MOBILE TO APPLY FOR PERMITTING AND CONTRACTORSPECIFICATIONS.REQUIRED TO COMPLETE THE JOB ACCORDING TO THE DRAWINGS ANDNON-STANDARD ANTENNA FRAMES AND ALL OTHER MATERIAL AND LABORAND/OR AUGER MOUNTS, MISCELLANEOUS FASTENERS, CABLE TRAYS,
DRILLING, SLEEPERS AND RUBBER MATTING, REBAR, CONCRETE CAISSONS, PADSELECTRICAL POWER, CONDUIT, LANDSCAPING COMPOUND STONE, CRANES, CORETRANSFORMERS AND DISCONNECT SWITCHES WHERE APPLICABLE, TEMPORARYWIRES, COPPER-CLAD OR XIT CHEMICAL GROUND ROD(S), BUSS BARS,
PLATFORM, ROOFING LABOR AND MATERIALS, GROUNDING RINGS, GROUNDINGMATERIALS AS FENCING, STRUCTURAL STEEL SUPPORTING SUB-FRAME FORCOMPLETE INSTALLATION OF THE SITE INCLUDING, BUT NOT LIMITED TO, SUCHTHE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL OTHER MATERIALS FOR THE
CONTRACTOR WILL INSTALL:OWNER FURNISHED MATERIALS, T-MOBILE "THE COMPANY" WILL PROVIDE AND THE
M.L.
K.J.I.H.
G.F.E.D.
C.B.
A.
O.N.
GENERAL NOTES:
THE EQUIPMENT AFTER PICKING UP.OPERATION, READY FOR USE. THE CONTRACTOR SHALL BE RESPONSIBLE FORCONTRACTOR WITH ALL APPURTENCES REQUIRED TO PLACE THE EQUIPMENT IN
WAREHOUSE, NO LATER THAN 48HR AFTER BEING NOTIFIED INSURED, STORED,T-MOBILE FURNISHED EQUIPMENT SHALL BE PICKED-UP AT THE T-MOBILE
CONTRACTOR SHALL FIELD LOCATE ALL BELOW GRADE GROUND LINES AND UTILITY LINES PRIOR TO CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR RELOCATION OF ALL UTILTITIES AND GROUND LINES THAT MAY BECOME DISTRUBED OR CONFLICTING IN THE COURSE OF CONTSTRUCTION.
, UNCRATED, PROTECTED AND INSTALLED BY THE
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
ONTAE I
expires 11-30-2006
F0 LLI
Y8109
E
A
ICL
PAC
TS
HT DAD
ESNE
D
CE
ANI K
SI
A.US
TTIHR C
BILL OF MATERIALS (FURNISHED BY T-MOBILE)
SAP # DESCRIPTION MODEL MANUFACTURER8531 S12000 S000 OD MAIN. AXX CSU. NO RADIOS BTS NTDS 25AB NORTEL
QTY
S12000 EXP. BTS NORTEL
NORTELNORTEL
ANDREWANDREWANDREWANDREW
ANDREWANDREW
ANDREW
ANDREWANDREWANDREW
EMSEMSEMSEMSEMS
ANDREWANDREWANDREW
ANDREW
ANDREWANDREW
ANDREWANDREWANDREWANDREW
ANDREWANDREWANDREWANDREWANDREWANDREWANDREWANDREW
NTINTI
ANDREWANDREW
ANDREWANDREW
ANDREWANDREWANDREWANDREWANDREW
6226823082327780778777897792779378007783
NTDS 25CBNTDS 25BAS12000 INDOOR MAIN BTS
48VDC INDOOR DC POWER50 AMP RECTIFIERAISG ASCU CONTROLLER-US R2 VER
IPRV20048VNOR
7782
77867785
6600678272786598
66017287728972917295
717968426771
71047105
734073477106
7161732373487358
6448645676107581
73337950
638663896046
67906775684468576784
1M CABLE ASSEMBLY FOR R2 ANTENNA3M CABLE ASSEMBLY FOR R2 ANTENNA6M CABLE ASSEMBLY FOR R2 ANTENNA9M CABLE ASSEMBLY FOR R2 ANTENNA60M CABLE ASSEMBLY FOR R2 ANTENNAJUNCTION BOX (4 WAY) FOR R2 ANTENNALIGHTNING PROTECTION KIT FOR R2 VERSIONY-SPLITTER FOR R2 ANTENNA3 WAY-SPLITTER (QUAD PORTS) FOR R2 ANTENNAANTENNA 65 DEG 18.5 DBI 2DEG EDT DUALPOLANTENNA 65 DEG 18.5 DBI 4DEG EDT QUAD
ANTENNA 65 DEG 18.5 DBI 2DEG EDT CROSSANTENNA 65 DEG 19 DBI 0 DEG DT CROSS POL
ANTENNA 65 DEG 18.5 DBI 4DEG EDT CROSS7/8IN AVA COAX CABLE 50 OHM 1 5/8IN AVA COAX CABLE 50 OHMCONNECTOR AVA 7/8IN DF POSITIVE STOPCONNECTOR AVA 1 5/8IN DF POSITIVE STOPTOP/BOTTOM BUSS BAR KIT WITH ATTACHMENTSTOP BUSS BAR KIT WITH ATTACHMENTSGROUNDING KIT FOR CONTROL CABLE R 1 VERGROUNDING KIT 7/8IN 2 HOLE LUGGROUNDING KIT 1 5/8IN 2 HOLE LUGHANGER. B-FLY. 1/2 IN. QTY 10HANGERS. SNAP- IN. 1/2 IN. KIT OF 101 5/8IN SNAP STACK HANGER (10 PER PACK)HANGERS. SNAP-IN 7/8IN. KIT OF 10HOIST GRIP 7/8INHOIST GRIP FOR 1 5/8IN CABLEJUMPER 8-FT SUPERFLEX DIN MALEJUMPER 3-FT SUPERFLEX DIM TO DIM LOW VSWRJUMPER 6-FT SUPERFLEX DIM TO DIM LOW VSWRNTI PPC BASE FOR OVER UNDER PPC200 AMP OVER AND UNDER PPC AND TELCO3 SECTOR FULLBAND INDOOR NORTEL LNA KITWEATHERPROOFING KIT FOR CONNECTOR170 AMP HR BATERIES MONPLE PLATFORM MNT FOR 30IN-60IN DIAMONPLE PLATFORM MNT FOR 10IN-30IN DIAFLAT ROOFTOP BALLST MOUNTD SECTOR FRAMEFLAT TOP ROOF BALLST MOUNTD SECTOR FRAMEWAVEGUIDE BRIDGE 45 DEGREE CORNER FILLERWAVEGUIDE BRIDGE 90 DEGREE CORNER FILLERWAVEGUIDE BRIDGE KIT.DIRECT BURIAL POST
DCPWR48V50 AVALATC200-LITEATCB-B01-001ATCB-B01-003ATCB-B01-006ATCB-B01-009ATCB-B01-060ATJB200-A01-004ATLP200-001ATS-A01-002ATS-B01-003DR651902DPQDR651904DPQRR651900DP5RR651902DP5RR651904DP5AVA5-50AVA7-50A5TDF-PSA7TDF-PSMTC6677MTC6714602299SGL5-06B2SGL7-06B2252119SSH-12SSH-158SSH-7819256B24312AF4A-PDMDM-8-TMBL4A-PDMDM-3-USAL4A-PDMDM-6-USA0602061-00CS7S2-W836PWAVFB-3NT8000BP-3221213BC-12V170 FT/4MCPA12L972MC-PA12S-9-72RF-N12-4-72RF-N12-3-72WB-CF45WB-CF90WB-K210-B
BOM-1
BILL OF MATERIALS(FURNISHED BY T-MOBILE)
BILL OF MATERIALS (FURNISHED BY T-MOBILE)SCALE: NTS1
1
6
2000
2463
36
159
12
12
11
3
12
12
(*) NOTE:
IF PLATFORM DOESNOT COME W/ TOWER- PM CHECK TOWER DRAWINGS & ERECTION BOOK
S12000 S000 OD EXT. AXXIU CSU. NO RADIOS BTS8532 NTDS 25AB NORTEL6312
1
24
CL-0910-UCABLE LADDER KIT 30"X 10"N/A ANDREW
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
ONTAE I
expires 11-30-2006
F0 LLI
Y8109
E
A
ICL
PAC
TS
HT DAD
ESNE
D
CE
ANI K
SI
A.US
TTIHR C
3
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
JULY
)
)) SS
12TH
CORRECT REPRESENTATION OF A WORK PERFORMED AT AND UNDER MY DIRECTION.
GIVEN UNDER MY HAND AND SEAL THIS DAY OF A.D., 2006
STATE OF ILLINOIS
COUNTY OF KANE
I, FRANK BRADKE, AN ILLINOIS PROFESSIONAL LAND SURVEYOR
FRANK BRADKE
MY LICENSE EXPIRES NOVEMBER 30, 2006ILLINOIS PROFESSIONAL LAND SURVEYOR NO. 35002507
THIS PLAN WAS PREPARED FOR THE LEASE SITE,ACCESS AND UTILITY EASEMENT SHOWN HEREON.
NUMBER 35002507, DO HEREBY DECLARE THAT THE PLAN SHOWN HEREON IS A
GENERAL NOTES
SURVEYOR AT ONCE.
DECIMAL PARTS THEREOF.
CONDITIONS WITH THE DATA GIVEN ON THIS PLAN AND REPORT ANY DISCREPANCIES TO THE
2. COMPARE DEED DESCRIPTION AND SITE
1. ALL DIMENSIONS ARE GIVEN IN FEET AND
SCALE MEASUREMENT.
ROW MARKER
FIRE HYDRANT
POWER POLE
LEGEND & SYMBOLS
LIGHT STANDARDINLETCATCH BASIN
3. NO DIMENSIONS SHALL BE DERIVED FROM
MAILBOX
TRAFFIC SIGNAL
MANHOLE
DECIDUOUS TREE W/SIZE
EVERGREEN TREE W/SIZE
TELEPHONE POLE
FLARED END SECTION
IRON PIPE FOUND
IRON PIPE SET
SIGN
BUFFALO BOX
TREE STUMP
HAND HOLE (TS)
TELEPHONE SPLICE BOX
CONTOUR
FENCE
686
x x
VEGETATION LINE
EXISTING GUARDRAIL
ELEVATION LOCATION
PROPOSED TOWER LOCATION
GAS MARKINGS PER JULIE
AMERITECH MARKINGS PER JULIE
AUXILIARY VALVE
PROPERTY LINE
HORIZONTAL CONTROL POINT
COM ED MARKINGS PER JULIE
OVERHEAD WIRES
LOCATION OF T-MOBILE LEASE AREA &
EASEMENT PLAN
LS-1
1LOCATION OF T-MOBILE LEASE AREA & EASEMENT PLAN
SCALE: 1" = 30' (1" = 60' IF 11 X 17 SHEET SIZE)
E
SE
NE
S
N
W
SW
NW
NEW 32'X40' T-MOBILE LEASE AREA
EXISTING UNDERGROUND WATER LINE
NEW 8-FT WIDE UTILITY EASEMENT
ALA
N D
R.
SOUTH DR.(Asphalt Paved)
STATE RO
UTE 31
ARBOR LANE
EXISTING WIRE FENCE
EXISTING UTILITY POLE
EXISTING GRAVEL
DRIVEWAY AREAEXISTING MANHOLE
EXISTING UTILITY POLE
EXISTING UNDERGROUND
WATER LINE
EXISTING UTILITY
POLE
GC TO REMOVE EXISTING TREES
AS NEEDED
EXISTING UTILITY
POLE
EXISTING TREE LINE
NEW LOCATION OF T-MOBILE TOWER
NEW LOCATION OF T-MOBILE STEEL PLATFORM
EXISTING MANHOLE
PROPERTY LINEPROPERTY LINE
PRO
PER
TY L
INE
PRO
PER
TY L
INE
PRO
PER
TY L
INE
PRO
PER
TY L
INE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINEPROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PRO
PERTY LIN
E
PRO
PERTY LIN
E
PROPERTY LINE
N 83° 48' 59" E 318.35'
S 83° 48' 59" W 309.81'
S 00° 25' 07" E 8.00'
N 9° 31' 54" E 8.00'
S 86° 35' 42" E 13.72'
N 86°35'42" E 16.48'
FLOOD PLAIN INFO:
AS PER FEMA'S FLOOD INSURANCE RATE MAP #17089C0070F, REVISED ON DECEMBER 20, 2002, PANEL #70 OF 410, THIS PROJECT SITE IS LOCATED WITHIN A 100-YEAR FLOODPLAIN / FLOODWAY AREA ZONE AE:
WITH BASE FLOOD ELEVATION DETERMINED AT 733 AMSL
PROJECT BENCHMARK #1: GAS VALVE (732.64' AMSL)
PROJECT BENCHMARK #2: PK NAIL @ EDGE OF
PAVEMENT (732.72' AMSL)
025 7
RF NAA
RK
DKEJ.
B
GERSI T
DERE
S I
OETAT L NOI
S
LI
S
SS
A
O
A DOI
OR
ER
E
LL
PF
N
UR
Y
N
V
F
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
LS-2
LEGAL DESCRIPTION
NUMBER 35002507, DO HEREBY DECLARE THAT THE PLAN SHOWN HEREON IS A
ILLINOIS PROFESSIONAL LAND SURVEYOR NO. 35002507
I, FRANK BRADKE, AN ILLINOIS PROFESSIONAL LAND SURVEYOR
GIVEN UNDER MY HAND AND SEAL THIS DAY OF A.D., 2006
CORRECT REPRESENTATION OF A WORK PERFORMED AT AND UNDER MY DIRECTION.
ACCESS AND UTILITY EASEMENT SHOWN HEREON.THIS PLAN WAS PREPARED FOR THE LEASE SITE,
MY LICENSE EXPIRES NOVEMBER 30, 2006
FRANK BRADKE
12th
COUNTY OF KANE
STATE OF ILLINOIS) SS)
)
JULY
P.O.B OF LEASE AREA
P.O.C
P.O.B OF UTILITY EASEMENT
S 86°23'50" W 40.00'
N 00°00'00" E 6.57'
N 86°23'50" E 40.00'
N 0
0°25
'07"
W 3
2.00
'
S 0
0°25
'07"
E 3
2.00
'
N 00°00'00" E 11.44'
AND
BEGINNING AT THE INTERSECTION OF THE CENTER LINE OF STATE ROUTE 31 WITH THE NORTH LINE SECTION 3, TOWNSHIP 42 NORTH, RANGE 8, EAST OF THE THIRD PRINCIPAL MERIDIAN; THENCE SOUTH 13 DEGREES 42 MINUTES EAST ALONG SAID CENTERLINE, 64.8 FEET; THENCE SOUTH 88 DEGREES 12 MINUTES EAST ALONG A LINE THAT IS PARALLEL WITH THE NORTH LINE OF SECTION 3 AFORESAID, 51.8 FEET TO THE EASTERLY RIGHT-OF-WAY LINE OF STATE ROUTE 31 AFORESAID; THENCE SOUTHERLY ALONG SAID RIGHT-OF-WAY LINE OF STATE ROUTE 31 AFORESAID; THENCE SOUTHERLY ALONG SAID RIGHT-OF-WAY LINE, 70.0 FEET FOR THE PLACE OF BEGINNING; THENCE SOUTH 88 DEGREES 12 MINUTES EAST ALONG A LINE THAT IS PARALLEL WITH THE NORTH LINE OF SECTION 3 AFORESAID 118.5 FEET; THEN SOUTH 13 DEGREES, 37 MINUTES EAST, 70.0 FEET; THENCE NORTH 88 DEGREES 12 MINUTES WEST, PARALLEL WITH THE NORTH LINE OF SECTION 3 AFORESAID, 118.80 FEET TO THE AFORESAID EASTERLY RIGHT-OF-WAY LINE OF STATE ROUTE 31; THENCE NORTHERLY ALONG SAID RIGHT-OF-WAY LINE, 70.0 FEET TO THE PLACE OF BEGINNING, SITUATED IN DUNDEE TOWNSHIP, KANE COUNTY, ILLINOIS. PIN NOS. A PORTION OF 03-03-142-017 AND 03-03-152-016 AND BEING THE SAME PROPERTY CONVEYED TO FOREST PRESERVE DISTRICT OF KANE COUNTY, A MUNICIPAL CORPORATION FROM THE ELGIN NATIONAL BANK, ELGIN, ILLINOIS A CORPORATION BY TRUSTEES DEED-INDIVIDUAL DATED MAY 7, 1985, AND RECORDED JUNE 25, 1992 IN INSTRUMENT NO. 92K45876, AND FURTHER CONVEYED TO THE VILLAGE OF ALGONQUIN, A MUNICIPAL CORPORATION FROM THE FOREST PRESERVE DISTRICT OF KANE COUNTY, A MUNICIPAL CORPORATION BY QUITCLAIM DEED DATED OCTOBER 30, 2000, AND RECORDED NOVEMBER 13, 2000 IN INSTRUMENT NO. 2000K090182TAX PARCEL NO. 03-03-152-023
PARCEL TWO. EASEMENT FOR INGRESS AND EGRESS CREATED BY WARRANTY DEED RECORDED AUGUST 23, 1976 AS DOCUMENT NO. 1375326 FOR THE BENEFIT OF PARCEL ONE OVER THAT PART OF THE NORTHWEST QUARTER OF SECTION 3, TOWNSHIP 42 NORTH, RANGE 8, EAST OF THE THIRD PRINCIPAL MERIDIAN, DESCRIBED AS FOLLOW A: COMMENCING AT THE INTERSECTION OF THE NORTH LINE OF SAID SECTION WITH THE CENTER LINE OF STATE ROUTE 31; THENCE SOUTH 13 DEGREES 42 MINUTES EAST ALONG SAID CENTER LINE, 64.8 FEET; THENCE SOUTH 88 DEGREES 12 MINUTES EAST ALONG A LINE THAT IS PARALLEL WITH THE NORTH LINE OF SAID SECTION 170 0 FEET, THENCE SOUTH 13 DEGREE 42 MINUTES EAST, 65.4 FEET; THENCE SOUTH 13 DEGREES 37 MINUTES EAST, 73 6 FEET, THENCE SOUTH 12 DEGREES 06 MINUTES EAST 68.25 FEET, THENCE SOUTH 10 DEGREES 12 MINUTES EAST, 74.25 FEET, THENCE SOUTH 88 DEGREES 12 MINUTES EAST PARALLEL WITH THE NORTH LINE OF SAID SECTION AFORESAID, 140.4 FEET, THENCE NORTH 11 DEGREES 29 MINUTES WEST TO THE NORTH LINE OF SAID NORTHWEST QUARTER FOR THE POINT OF BEGINNING, THENCE SOUTH 11 DEGREES 29 MINUTES EAST 415 FEET, THIS LINE HEREINAFTER REFERRED TO AS LINE "A"; THENCE SOUTH 88 DEGREES 12 MINUTES EAST PARALLEL WITH THE NORTH LINE OF SAID QUARTER SECTION TO A LINE DRAWN PARALLEL WITH AND 60 FEET EASTERLY OF, MEASURED AT RIGHT ANGLES THERETO, LINE "A" AFORESAID; THENCE NORTH 11 DEGREES 29 MINUTES WEST 415 FEET TO THE NORTH LINE OF SAID NORTHWEST QUARTER; THENCE NORTH 88 DEGREES 12 MINUTES WEST ALONG SAID NORTH LINE TO THE POINT OF BEGINNING (EXCEPT THE NORTH 64 FEET THEREOF, MEASURED AT RIGHT ANGLES TO THE NORTH LINE OF SAID QUARTER SECTION, AND ALSO THAT PART LYING SOUTHERLY OF THE SOUTHERLY LINE EXTENDED EASTERLY OF PARCEL ONE), IN THE TOWNSHIP OF DUNDEE, KANE COUNTY, ILLINOIS.
PARCEL THREE: EASEMENTS FOR INGRESS AND EGRESS CREATED BY GRANT RECORDED MARCH 14, 1989 AS DOCUMENT NO 1962368 FOR THE BENEFIT OF PARCEL ONE, MORE PARTICULARLY DESCRIBED AS FOLLOWS: THE NORTH 64 FEET, MEASURED AT RIGHT ANGLES TO THE NORTH LINE OF THE NORTHWEST QUARTER OF SECTION 3, TOWNSHIP 42 NORTH, RANGE 8, EAST OF THE THIRD PRINCIPAL MERIDIAN, AND DESCRIBED AS FOLLOWS: COMMENCING AT THE INTERSECTION OF THENORTH LINE OF SAID SECTION WITH THE CENTER LINE OF STATE ROUTE 31, THENCE SOUTH 13 DEGREES 42 MINUTES EAST ALONG SAID CENTER LINE OF SAID SECTION WITH THE CENTER LINE 64.8 FEET, THENCE SOUTH 8 DEGREES 12 MINUTES EAST ALONG A LINE THAT IS PARALLEL WITH THE NORTH LINE OF SECTION, 170 0 FEET, THENCE SOUTH 13 DEGREES 42 MINUTES EAST, 65 4 FEET, THENCE SOUTH 13 DEGREES 37 MINUTES EAST, 73.6 FEET; THENCE SOUTH 12 DEGREES 06 MINUTES EAST 68.25 FEET, THENCE SOUTH 10 DEGREES 12 MINUTES EAST, L74 25 FEET; THENCE SOUTH 88 DEGREES 12 MINUTES EAST PARALLEL WITH THE NORTH LINE OF SAID SECTION AFORESAID, 140 4 FEET, THENCE NORTH 11 DEGREES 29 MINUTES WEST TO THE NORTH LINE OF SAID NORTHWEST QUARTER FOR THE POINT OF BEGINNING, THENCE SOUTH 11 DEGREES 29 MINUTES EAST 415 FEET, THIS LINE HEREINAFTER REFERRED TO AS LINE "A", THENCE SOUTH 88 DEGREES 12 MINUTES EAST PARALLEL WITH THE NORTH LINE OF SAID QUARTER SECTION T A LINE DRAWN PARALLEL WITH AND 60 FEET EASTERLY OF, MEASURED AT RIGHT ANGLES THERETO, LINE "A" AFORESAID; THENCE NORTH 11 DEGREES 29 MINUTES WEST 415 FEET TO THE NORTH LINE OF SAID NORTHWEST QUARTER; THENCE NORTH 88 DEGREES 12 MINUTES WEST ALONG SAID NORTH LINE TO THE POINT OF BEGINNING IN THE TOWNSHIP OF DUNDEE, KANE COUNTY, ILLINOIS. PERMANENT REAL ESTATE INDEX NUMBER 03-02-152-014
PARCEL ONE: THAT PART OF THE NORTHWEST QUARTER OF SECTION 3, TOWNSHIP 42 NORTH, RANGE 8, EAST OF THE THIRD PRINCIPAL MERIDIAN, DESCRIBED AS FOLLOWS: COMMENCING AT THE INTERSECTION OF THE NORTH LINE OF SAID SECTION WITH THE CENTER LINE OF STATE ROUTE 31; THENCE SOUTH 31 DEGREES 42 MINUTES EAST ALONG SAID CENTER LINE, 64.8 FEET, THENCE SOUTH 88 DEGREES 12 MINUTES EAST ALONG A LINE THAT IS PARALLEL WITH THE NORTH LINE OF SECTION, 170 0 FEET, THENCE SOUTH 13 DEGREES 42 MINUTES EAST, 65.4 FEET; THENCE SOUTH 13 DEGREES 37 MINUTES EAST, 73.6 FEET, THENCE SOUTH 12 DEGREES 06 MINUTES EAST, 68.25 FEET FOR THE POINT OF BEGINNING; THENCE SOUTH 10 DEGREES 12 MINUTES EAST 74.25 FEET, THENCE SOUTH 88 DEGREES 12 MINUTES EAST, PARALLEL WITH THE NORTH LINE OF SAID SECTION AFORESAID, 140.4 FEET; THENCE NORTH 11 DEGREES 29 MINUTES WEST, 71.0 FEET; THENCE NORTH 87 DEGREES 16 MINUTES WEST, 138.2 FEET TO THE POINT OF BEGINNING, IN THE TOWNSHIP OF DUNDEE, KANE COUNTY, ILLINOIS.
LEGAL DESCRIPTIONPARENT PARCEL
AND BEING THE SAME PROPERTY CONVEYED TO MARLENE CUCHNA FROM JOSEPH THOMAS JACOB BY WARRANTY DEED DATED NOVEMBER 22, 2002, AND RECORDED DECEMBER 5, 2002 IN DEED BOOK 2002, PAGE 160891. TAX PARCEL NO. 03-02-152-014
AND
THAT PART OF THE NORTHWEST QUARTER OF SECTION 3, TOWNSHIP 42 NORTH, RANGE 8 EAST OF THE THIRD MERIDIAN DESCRIBED AS FOLLOWS:COMMENCING AT THE INTERSECTION OF THE NORTH LINE OF SAID SECTION 3 WITH THE CENTERLINE OF STATE ROUTE 31; THENCE SOUTHEASTERLY ALONG SAID CENTERLINE 133.11 FEET; THENCE EASTERLY ALONG A LINE FORMING AN ANGLE 74 DEGREES 30 MINUTES 59 SECONDS TO THE LEFT WITH THE PROLONGATION OF THE DESCRIBED COURSE 167.11 FEET; THENCE EASTERLY ALONG A LINE FORMING AN ANGLE OF 100 DEGREES 44 MINUTES 48 SECONDS WITH THE LAST DESCRIBED COURSE 145.51 FEET TO A POINT ON THE WESTERLY LINE OF ALAN DRIVE, SAID POINT BEING THE PLACE OF BEGINNING; THENCE SOUTHEASTERLY 104 DEGREES 53 MINUTES 48 SECONDS ALONG SAID WESTERLY LINE 302.90 FEET; THENCE EASTERLY ALONG A LINE FORMING AN ANGLE OF 102 DEGREES 24 MINUTES 37 SECONDS WITH THE LAST DESCRIBED COURSE 208.64 FEET TO A POINT ON THE WESTERLY SHORELINE OF THE FOX RIVER; THENCE NORTHEASTERLY ALONG SAID WEST LINE 278.70 FEET TO A POINT ON A LINE OF SECTION 3; THENCE WESTERLY AND PARALLEL WITH SAID NORTH LINE 265.86 FEET TO A POINT ON THE EASTERLY LINE OF ALAN DRIVE; THENCE NORTHWESTERLY 64 +/- FEET TO THE PLACE OF BEGINNING, BEGIN SITUATED IN KANE COUNTY, ILLINOIS.
LEGAL DESCRIPTIONPARENT PARCEL
LEGAL DESCRIPTIONT-MOBILE LEASE AREA
COMMENCING AT THE SOUTHWEST CORNER OF THE AFOREDESCRIBED PARENT PARCEL: THENCE
N 00°00'00" W 6.57'; TO THE POINT OF BEGINNING, THENCEN 86°23'50" E 40.00'; THENCEN 00°25'07" W 32.00'; THENCES 86°23'50" W 40.00'; THENCES 00°25'07" E 32.00' TO TERMINATE AT THE POINT OF BEGINNING CONTAINING 1280.00 SQUARE FEET, ALL CONTAINED WITH KANE COUNTY, ILLINOIS.
COMMENCING AT THE SOUTHWEST CORNER OF THE AFOREDESCRIBED PARENT PARCEL: THENCE
N 00°00'00" W 11.44'; TO THE POINT OF BEGINNING, THENCES 86°35'42" W 13.72'; THENCES 83°48'59" W 309.81'; THENCEN 09°31'53" E 8.00'; THENCEN 83°48'59" E 318.35'; THENCEN 86°35'42" E 16.48'; THENCES 00°25'07" E 8.00' TO TERMINATE AT THE POINT OF BEGINNING CONTAINING 2997.54 SQUARE FEET, ALL CONTAINED WITH KANE COUNTY, ILLINOIS.
LEGAL DESCRIPTIONNEW T-MOBILE UTILITY EASEMENT
NEW 32'X40' T-MOBILE
LEASE AREA
025 7
RF NAA
RK
DKEJ.
B
GERSI T
DERE
S I
OETAT L NOI
S
LI
S
SS
A
O
A DOI
OR
ER
E
LL
PF
N
UR
Y
N
V
F
X X X X X X X
X X X X X X X
3'-0"
10'-10" TO C
ENTER
O
F TOW
ER
8'-2" TO CENTER
OF TOWER
6'-11"
5'-0"12'-0"
16'-7"
6'-6"
7'-11"
2'-8"
3'-0"
NEW 40'-0" T-MOBILE LEASE AREA
NE
W 32'-0" T-M
OB
ILE LE
AS
E A
RE
A
1'-7"
6'-4"2'-9"13'-9"
A-1
ENLARGED SITE PLAN
ENLARGE SITE PLANSCALE: 1/4" = 1'-0" (1/4" = 2'-0" IF 11 X 17 SHEET SIZE)1 W
NW
SWS
ENE
N
SE
AZIMUTH: 0°SECTOR A
SECTOR CAZIMUTH: 240°
SECTOR BAZIMUTH: 120°
NEW 8-FTWIDE UTILITYEASEMENT
EXISTING GRASS AREA
NEW 120-FT HIGH MONOPOLE
NEW 6'-4" x 13'-9" STEEL PLATFORM W/ NEW STEEL LADDER TO BE FURNISHED & INSTALLED BY GC
NEW T-MOBILE ANTENNA MOUNTW(6) NEW PANEL ANTENNAS TO BE LOCATED AT 120.0' CENTERLINE ELEVATION; FURNISHED BY GENERAL CONTRACTOR
GC TO REMOVE EXISTING TREES
AS NEEDED
NEW 6'-0" HIGH T-MOBILE ICE BRIDGE TO BE FURNISHED BY T-MOBILE & INSTALLED BY GENERAL CONTRACTOR.
NEW UTILITY RACK W/ NEW TELCO DEMARCATION, 200A, 120/240V METER BASE, LIGHT AND PPC CABINET FURNISHED & INSTALLED BY GENERAL CONTRACTOR. (PPC CABINET FURNISHED BY T-MOBILE.)
NEW 32'X40' T-MOBILE LEASE AREA
NEW GRAVEL COMPOUND
INSIDE FENCED AREA
EXISTING GRAVEL
ENTRANCE
EXISTING UNDERGROUND WATER LINE PROTECT DURING CONSTRUCTION
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
ONTAE I
expires 11-30-2006
F0 LLI
Y8109
E
A
ICL
PAC
TS
HT DAD
ESNE
D
CE
ANI K
SI
A.US
TTIHR C
EXISTING UNDERGROUND
SEWER LINE
NEW CHAINLINK FENCE TO MATCH HEIGHT OF EXISTING FENCE. TO BE FURINSHED & INSTALLED BY GC
NEW 12FT WIDE CHAIN-LINK FENCE GATE
(1) PRIMARY & (2) FUTURE S12000 T-MOBILE OUTDOOR CABINETS, FURNISHED BY T-MOBILE & INSTALLED BY GC
EXISTING MANHOLE
PROPERTY LINE
EXISTING CHAINLINK FENCE
PROPERTY LINE
NEW CHAINLINK FENCE TO MATCH HEIGHT OF EXISTING FENCE. TO BE FURINSHED & INSTALLED BY GC
T/ FINISH GRADE
ELEV.=732.0'
MATCH EXISTINGELEVATION
T/ CONC. PIERS
ELEV.= 734.00' (TYP.)
MATCH EXISTING
ELEVATION
MATCH EXISTING
ELEVATION
MATCH EX
ISTING
ELEV
ATION
MATCH EXISTING
ELEVATION
MATCH EXISTING
ELEVATION
MATCH EXISTING
ELEVATION
T/ CONC. PIER
ELEV.= 732.80'
A-2
SITE ELEVATION
SITE ELEVATIONSCALE: 1/8"= 1'-0" (1/8"=2'-0" IF 11X17 SHEET SIZE)
1
4 ENLARGED SITE ELEVATIONSCALE: N.T.S.
NEW T-MOBILE MOUNT w/(6) NEW PANEL ANTENNAS TO BE
LOCATED AT 120-FT CENTERLINE ELEVATION; FURNISHED BY T-MOBILE, INSTALLED BY GENERAL
CONTRACTOR.(STRUCTURAL ANALYSIS BY OTHERS)
NEW STEEL STEP-BOLTS & SAFETY LINE FOR TOWER CLIMBING.
ENLARGED ANTENNA ELEVATION DETAILSCALE: N.T.S.2
CL OF NEW T-MOBILE ANTENNAS ELEV. ±120'-0" (AGL)
EXISTING GRADE
NEW 6-FT HIGH PANEL ANTENNA (TYP.)
12'-0"
NEW ANTENNA MOUNTING PIPE (TYP.)
NOTE:
1- ROUTING SHALL BE INSIDE NEW MONOPOLE - GENERAL CONTRACTOR TO FURNISH & INSTALL ALL NECESSARY HARDWARE FOR COAX ROUTING.
NEW T-MOBILE 6'-4"X13'-9" STEEL PLATFORM TO BE FURNISHED & INSTALLED BY GENERAL CONTRACTOR.
FUTURE BTS PRIMARY BTS
NEW T-MOBILE COAX CABLES TO BE FURNISHED BY
T-MOBILE, INSTALLED BY GENERAL CONTRACTOR.
CONTRACTOR TO UTILIZE ENTRY PORT FOR ROUTING OF
COAX CABLES TO ANTENNA ELEVATION
6" MIN. COMPACTED GRAVEL BASE FURNISHED & INSTALLED BY GC.
NEW LOWER GROUND BARA-2
NEW PRIMARY & FUTURE S12000 T-MOBILE OUTDOOR CABINETS, FURNISHED BY T-MOBILE, INSTALLED BY GENERAL CONTRACTOR.
SEE DETAIL 4
TOP OF STRUCTURE w/LIGHTNING RODELEV. ±124'-0" (AGL)
NEW PRIMARY & FUTURE S12000 T-MOBILE OUTDOOR CABINETS,
FURNISHED BY T-MOBILE, INSTALLED BY GENERAL CONTRACTOR.
FUTURE BTS
NEW 6'-0" HIGH T-MOBILE ICE BRIDGE TO BE FURNISHED BY T-MOBILE & INSTALLED BY GENERAL CONTRACTOR.
NEW 120'-0" HIGH MONOPOLE w/4-FT HIGH LIGHTNING ROD; FURNISHED BY T-MOBILE, INSTALLED BY GENERAL CONTRACTOR.
NEW 6'-0" HIGH T-MOBILE ICE BRIDGE TO BE FURNISHED BY
T-MOBILE & INSTALLED BY GENERAL CONTRACTOR.
3
GC TO VERIFY FINAL HOOKUP LOCATIONS w/T-MOBILE ENGINEER, RF ENGINEER & NETOPS PRIOR TO INSTALLATION.
COAX DETAILSCALE: 1"=1'-0" (1"=2'-0" IF 11X17 SHEET SIZE)
NEW UTILITY RACK WITH NEW TELCO DEMARCATION BOX, 200A, 120/240V METER BASE, LIGHT AND PPC CABINET FURNISHED & INSTALLED BY GC (PPC CABINET TO BE FURNISHED BY T-MOBILE)
NEW UTILITY RACK WITH NEW TELCO DEMARCATION BOX, 200A, 120/240V METER BASE, LIGHT AND PPC CABINET FURNISHED & INSTALLED BY GENERAL CONTRACTOR (PPC CABINET TO BE FURNISHED BY T-MOBILE)
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
ONTAE I
expires 11-30-2006
F0 LLI
Y8109
E
A
ICL
PAC
TS
HT DAD
ESNE
D
CE
ANI K
SI
A.US
TTIHR C
NEW CHAINLINK FENCE TO MATCH HEIGHT OF EXISTING FENCE. FURNISHED & INSTALLED BY GC
PLINTH
0'-0"± (AGL)731.80' (AMSL)
1'-0"± (AGL) (*)732.80' (AMSL)
TOP OF TOWER FOUNDATION
NOTE (*): THE 1'-0" (AGL) ELEVATION IS BASED ON A WORST CASE SCENARIO. GC SHALL CONSULT WITH ACTUAL SITE SPECIFIC FOUNDATION DRAWINGS FOR FOR EXACT TOP OF FOUNDATION ELEVATION DIFFERENCE. IF NO FOUNDATION DRAWINGS ARE PRESENT AT THE TIME OF THE PRE-CON -- GC SHALL NOTIFY T-MOBILE AND ENGINEER IMMEDIATELY!
2.8'± (AGL)(*)734.00' (AMSL)
TOP OF PIER FOUNDATION
EXISTING GRADE 0'-0"± (AGL)731.80' (AMSL)
1'-0"± (AGL) (*)732.80' (AMSL)
TOP OF TOWER FOUNDATION
NEW T-MOBILE STEEL LADDER TO BE FURNISHED
& INSTALLED BY GC
ANTENNA DETAILS
A-3
NEW T-MOBILE MOUNT w/ (6) NEW PANEL ANTENNAS TO
BE MOUNTED @ 120-FT CENTERLINE ELEVATION,
FURNISHED & INSTALLED BY GENERAL CONTRACTOR.
AZIMUTH: 0°
AZIMUTH: 240°SECTOR C
AZIMUTH: 120°SECTOR B
SECTOR A
GENERAL CONTRACTOR TO LABEL EACH ANTENNA FRONT & BACK W/ BLACKLETTERING AS SHOWN IN ANTENNA PLATFORMELEVATION. LETTRASET BRAND, 3" HIGH, OUT-DOOR LETTERING OR APPROVED EQUAL, TOBE USED. LETTERING TO BE VISIBLE FROMGROUND USING BINOCULARS.
NOTES:
ANTENNA SCHEDULE
SECTOR A B C
ANTENNA MODEL No.
DOWNTILT BRACKET MODEL No.
ANTENNA MFR.
AZIMUTH
DOWNTILT BRACKET
DOWNTILT BRACKET
0° 120°
INITIAL ANTENNAS PER SECTOR 2
DOWNTILT BRACKET
240°
CONTRACTOR TO VERIFY WITH T-MOBILE PROJECT MANAGER ON VERTICAL & HORIZONTAL SEPARATION BETWEEN DIRECTIONAL ANTENNAS & ANTENNA TYPE WITH NUMBER OF COAX RUNS
A2R2R4R3R1
A1
B3B1
B1
B2
B4B2C1
W3
W1
W4
W2
C2
ANTENNA ORIENTATIONN.T.S.1
MECHANICAL DOWNTILT 0° 0° 0°
NOTES:
NEW T-MOBILE ANTENNA AZIMUTH TO BE FROM TRUE NORTH.
FRONT BACK
TX2 / RX DIVERSITY
TX4
TX3
TX1 / RX MAIN
A1 A1 A2
NOTES:
COAX SCHEDULE SINGLE COAX RUN
FIELD FABRICATE BTS JUMPERS*
C
B
A
SECTOR
150'-0"7/8" ~MAIN COAX
*
ANTENNA JUMPER
BTS JUMPER
MAIN COAX
BTS JUMPER
LNA JUMPER TO COAX 1/2" ~
1/2" ~
1/2" ~
1/2" ~
ANTENNA JUMPER
BTS JUMPER
MAIN COAX
LNA JUMPER TO COAX
1/2" ~
1/2" ~
1/2" ~
6'-0"
8'-0"
*8'-0"
3'-0"
3'-0"
6'-0"
*8'-0"
FUNCTION
ANTENNA JUMPER
LNA JUMPER TO COAX
1/2" ~
1/2" ~
DIAMETER
3'-0"
6'-0"
LENGTH
NEW LNA FOR RX ANTENNAS
NEW PANEL ANTENNA
ANTENNA MOUNTING PIPE
1/2" COAX JUMPERS
COAX CABLES TO BTS
ANTENNA DETAIL1"= 1'-0" (1"=2'-0" IF 11X17 SHEET SIZE)2
NEW 3'-0" JUMPER
DOWNTILT ASSEMBLY REQUIRED FOR ALL PANEL TYPE ANTENNAS
NOTE:LNA'S CONNECTED TOANTENNAS: - A1 & A2 - B1 & B2 - C1 & C2
1
A2
E
W
S
SW
SE
N
NW NE
TAPE RINGS MUST BE VISIBLE (WITH BINOCULARS) FROM
COAX CABLE AND JUMPERS SHALL BE MARKED AT BOTH THE TOP AND THE BOTTOM, 10" FROM EACH END.
GROUND AND BE COLORED IN ACCORDANCE WITH THEABOVE TABLE.
NOTES:
2)
1)
TX2/ RX DIVERSITY
TX2/ RX DIVERSITY
TX2/ RX DIVERSITYC TX1/ RX MAIN
TX3TX4
B TX1/ RX MAIN
TX3TX4
TX4TX3
2 REDA2SECONDARY
1 WHITE2 WHITE
4 WHITE3 WHITE
C1MAINSECONDARYRESERVERESERVE
C1C2
C2
2 BLUE1 BLUE
4 BLUE3 BLUE
MAIN
RESERVERESERVESECONDARY
B1B2
B2B1
RESERVERESERVE
A1A2
3 RED4 RED
MAIN COAX COLOR CODE SCHEDULESECTOR
A
FUNCTION
TX1/ RX MAIN
COLORREFERENCE
MAIN
ANTENNA
A1 1 RED
EMS
RR6519-02DP
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
ONTAE I
expires 11-30-2006
F0 LLI
Y8109
E
A
ICL
PAC
TS
HT DAD
ESNE
D
CE
ANI K
SI
A.US
TTIHR C
7/8" ~
7/8" ~
2 2
EMS EMS
RR6519-02DP
RR6519-02DP
150'-0"
150'-0"
PLINTH COVER PLATE
4" PVC PIPE (3" LONG)
LIQUID TIGHT RUN TO ALPHA + BETA (TYP.2)
6"X6" NEMA 3R PULL BOX TO BE FURNISHED & INSTALLED BY GC
BETA PLINTH & WITH (2) RUNS LIQUID TIGHT TO ALPHA + GAMMA
CABINETS
NEW PULL BOX
ALPHABETAGAMMA
GROUND BAR PLINTH (TYP.)
NOTE: JUMPER CABLE TO BE USED
A-4
LNA DETAILS
BETWEEN FEEDER AND LNA
FEEDER
3' JUMPER CABLE
LNA
NOTE: 1. LNA TO BE INSTALLED BY GENERAL CONTRACTOR
ANTENNA MOUNTINGBRACKET
6' JUMPER CABLE TO COAXCABLE FEEDER
3' JUMPER
NEW LNA FOR RXANTENNAS.
2 1/2" DIA. PIPEGALV. 54" LG.
JUMPER BRACKET
NEW 6'-0" JUMPER
NEW LNA FOR RXNEW 3'-0" JUMPER
LNAGALV.
42"
54" LG.
MFG:EMS(REFER TO COAX CHART)
ANTENNA
3' JUMPER CABLE
6' JUMPER CABLE
TMA
JUMPERSPOWER CABLE
ALARM CABLEPDUFEEDER
CIN CABLE
RF CABLE TO BTS
SYSTEM OVERVIEWSCALE: NTS5 HOSE CLAMP MOUNTING
SCALE: NTS6PANEL ANTENNASCALE: NTS4
JUMPERSSCALE: NTS1 LNA LOCATION
SCALE: NTS2 4" NIPPLE DETAILSCALE: NTS3
4" THREDED STEEL NIPPLE W/ LOCK NUT
MOUNTING BASE (INTERIOR)
UNIVERSAL PLATES
MOUNTING BASE (EXTERIOR)
4" MIN. SPACING BETWEEN CABINETS REQUIRED
MOUNTING BASE (EXTERIOR)UNIVERSAL PLATES
MOUNTING BASE (INTERIOR)
ANTENNA MAST PIPE
LNA
HOSE CLAMP(LNA MOUNT TO PIPE)
HOSE CLAMP(LNA MOUNT TO PIPE)
NOTES: 1. PIPE MOUNTING HARDWARE SUPPLIED WITH LNA KIT2. LNA'S NOT MOUNTED ON PIP MOUNTS, HARDWARE TO BE PROVIDED BY GENERAL CONTRACTOR.
NEW PULL BOX W/LIQUIDTIGHT RUN TO EACH BTS (A,B,G)SCALE: NTS7
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
ONTAE I
expires 11-30-2006
F0 LLI
Y8109
E
A
ICL
PAC
TS
HT DAD
ESNE
D
CE
ANI K
SI
A.US
TTIHR C
STYMIELOCK DETAIL
WOVEN WIRE FENCE
CLEARANCE1 1/2" MAX
FROM GRADE
DIAGONAL ROD W/
SE
E P
LAN
FO
R H
EIG
HT
TERMINAL OR PULL POSTWOVEN WIRE CORNER, GATE,
12"
1" C
RO
WN
3'-3
"
3'-6
"
FROM GRADE
TENSION WIRE
FINISH GRADE
1 1/2" MAXCLEARANCE
BOTTOM
TYPICALELEVATION
CORNER, TERMINAL OR PULL POST
1'-0
" BA
RB
ED
WIR
E
L C
BARBED WIRE
TOP BRACE RAIL
STRETCHERBAR
3 STRANDS
WIRE
BOTTOM
BARBED WIRE
TENSION
RAIL
HORIZONTAL RAILS
TENSION WIRE
TOP
WOVEN WIRE SWING GATE, DOUBLE
GATE MOUNTING
WIRE FENCE
TYPICAL SECTION
LINE POST FOOTING0'-12"
FACILITY SIDE
RAIL
8'-0
" (U
NO
)
EXTERIOR
WIRETENSION
SIDE
1" C
RO
WN
ARMSEXTENSION
TOP45°
CHAIN LINK FENCE
3'-6
"
FIN. GRADE
ALL AROUND (TYP)GROUND AND SLOPEPROJECT 1" ABOVE
TOP STRAND OF BARBED WIRE
CHAIN LINK FENCETOP OF
FENCE MOUNTING
MOUNTING BRACKET
AND PRODUCTS(773) 463-7010
#WPA-3, TRUELINK FENCE
GATE POST
EXTERIOR
GATE LATCH
OR EQUIVALENTSTYMIELOCK
(773) 463-7010
WIRE FENCE
FENCE POST
INTERIOR
#WPA-2, TRUELINK FENCEMOUNTING BRACKET
AND PRODUCTS
14. ALL HARDWARE TO BE HOT DIP GALVANIZED.
13. PICKETS TO BE 7/8 " THICK NO. 1 SPRUCE (IF APPLICABLE).
12. ALL WOOD FENCE RAILS TO BE NO. 2 PINE CCA PRESSURE TREATED LUMBER (IF APPLICABLE).
2. LINE POST: 2 1/2"Ø SCHEDULE 40 PIPE PER ASTM-F1083.
7. TENSION WIRE: 7 GA. GALVANIZED STEEL.
A SINGLE WRAP OF FABRIC TIE AND AT TENSION WIRE BY HOG
3. GATE FRAME: 1 1/2"Ø SCHEDULE 40 PIPE PER ASTM-F1083.
AND LOCK, KEYED ALIKE FOR ALL SITES IN A GIVEN MTA.
11. HEIGHT = SEE SITE PLAN FOR HEIGHT
(INSTALL FENCING PER ASTM F-567, SWING GATES PER ASTM F- 900)
8. BARBED WIRE: DOUBLE STRAND 12-1/2" O.D. TWISTED WIRE TO MATCH W/ FABRIC 14 GA., 4 PT. BARBS SPACED ON APPROXIMATELY 5" CENTERS.
9. GATE LATCH: 1-3/8" O.D. PLUNGER ROD W/ MUSHROOM TYPE CATCH
6. TIE WIRE: MINIMUM 9 GA. GALVANIZED STEEL AT POSTS AND RAILS
5. FABRIC: 9 GA. CORE WIRE SIZE 2 1/4" MESH, CONFORMING TO ASTM-A392.
1. GATE POST, CORNER, TERMINAL OR PULL POST 2 1/2"Ø SCHEDULE 40 FOR GATE WIDTHS UP THRU 6 FEET OR 12 FEET FOR DOUBLE SWING
10. LOCAL ORDINANCE OF BARBED WIRE PERMIT REQUIREMENT SHALL BE
4. TOP RAIL & BRACE RAIL: 1 5/8"Ø SCHEDULE 40 PIPE PER ASTM-F1083.
GATE PER ASTM-F1083.
GATE POST
COMPLIED IF REQUIRED.
RINGS SPACED MAX 24" INTERVALS.
TYPICAL FENCING NOTES
GENERAL NOTES
1. NO SCREENING SHALL INTERFERE WITH SIGHT REQUIREMENTS FOR SAFE INGRESS AND EGRESS.
2. WEED CONTROL FABRIC SHALL BE USED UNDER ALL AREAS OF THE YARD & DRIVE
3. DURING CONSTRUCTION, GENERAL CONTRACTOR WILL CONFORM TO THE INDIANA STANDARD PROCEDURES FOR EROSION CONTROL BASED ON "THE INDIANA PROCEDURES FOR URBAN SOIL EROSION AND SEDIMENTATION CONTROL MANUAL", LATEST EDITION.
4. CONTRACTOR TO VERIFY LOCATION OF EXISTING BELOW GRADE UTILITIES PRIOR TO CONSTRUCTION.
DETAIL "B" POST FOOTING
CORNER, GATE ANDLINE POST FOOTING
FINISHGRADE
(MIN
.)3'
-6"
GATE CORNER & LINE POST12'-0"
3'-3
"C
HAM
FER
1"
TRUSS ROD
2 1/2" DIA. (2 3/8" O.D. LINE POST)3" DIA. (2 7/8" O.D. GATE POST)3" DIA. (2 7/8" O.D.) CORNER POST
12'-0
" (M
AX
.)
SEE DETAIL "B"
SEE DETAIL "B"
1 NEW CHAIN LINK FENCE DETAILS & NOTESSCALE: NTS
FENCE DETAILS
A-5
4"
1"
MUSHROOM CAP DETAIL
MAX.
CENTER GATE STOPEMBEDDED IN CONC
1'-0"
1" CROWN (TYP.)
1-1/2"
2'-6
"
PLUNGER BAR
W/STEEL TURNBUCKLE
15. ALL MATERIALS ARE FURNISHED, DELIVERED & INSTALLED BY CONTRACTOR.
LOCK PROVIDED BY GC
3'-0"
DOUBLE SWING GATE - CLR OPNGWIDTH VARIES (SEE PLANS)
GATESNOW
CENTER GATE STOPEMBEDDED IN CONCRETE
GATE FRAME
FINISH GRADE
1 1/2"(MAX)
TOP
STRETCHER
W/STEEL DIAGONAL ROD
TURNBUCKLE
BAR
TENSION WIRE
BRACE RAILAT GATE
L GATE POSTC
6'-0
"4'-0
"
PLUNGER BAR
15"
WITH LOCKGATE LATCH
SEE DETAIL "B"
BARBEDWIRE
L C GATE
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
ONTAE I
expires 11-30-2006
F0 LLI
Y8109
E
A
ICL
PAC
TS
HT DAD
ESNE
D
CE
ANI K
SI
A.US
TTIHR C
EXISTING GRADE
DRIVEWAY WIDTH (SEE SITE PLAN)
2%2%
9" BASE COURSE (6" BREAKER RUN, 3"- 1 1/2")COMPACTED TO 95% MOD. PROCTOR
EXCAVATE FOR AGGREGATEBASE COURSE
NOTE: 1. EXCAVATED MATERIAL SHALL BE REMOVED AND DEPOSITED OFF-SITE2. GRADE DRIVEWAY PARKING AREA & TOWER COMPOUND @ 2% SLOPE TO PROVIDE DRAINAGE
CROWN ACCESS ROAD @ 2%
FENCED IN COMPOUND SEE SITE PLAN
NOTES:
F1. REMOVE TOP 6 - INCHES OF GRADE ROM COMOUND.P2. SCARIFY TOP 6 - INCHES AND COMPACT SUBGRADE.
GEOTEXTILE FABRICWEED BARRIER TOBE PLACED UNDERGRAVEL. MIRAFI 500XOR APPROVED EQUAL
SCARIFY TOP 6" ANDCOMPACT SUBGRADE
6" CRUSHED STONEOVER WEED BARRIER
PROPOSED CHAINLINK FENCE
1'-0"
6"
1'-0"
EXTEND GRAVEL 1'-0" BEYOND FENCE LINE, TYP.NOT TO EXCEED LEASE AREA
2% SLOPE 2% SLOPE
1'-6
" MIN
.2'
-0" M
IN.
6"
6'-0" MAX.
LINE
FLOW
WELDED WIRE ORCHICKEN WIREFENCING
SEDIMENT CONTROL FABRIC ATTACHEDUSING "HOG RINGS" OR PLASTIC TIES
COMPACTED SOILBACKFILL
KEY 8"- 12" OF FABRIC INTO TRENCH
"LUGGED-U" OR "T" STEELFENCE POST (TYP.)
GRAVEL ACCESS ROAD AND PARKING AREA DETAILSCALE: N.T.S.2
SOIL EROSION CONTROLSCALE: N.T.S.1
3 SITE COMPOUND GRAVEL DETAILSCALE: N.T.S.
A-6
GENERAL CONTRACTOR SHALL PROVIDE AT HIS/HER OWN EXPENSE ANY AND ALL SOIL EROSION CONTROL MEASURES/FENCING AROUND ALL AREAS THAT HAVE A GRADE IN EXCESS OF 5% OR WHERE THERE IS POTENTIAL FOR SOIL EROSION AND SOIL RUN-OFF DURING THE CONSTRUCTION PHASE OF THE PROJECT
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
ONTAE I
expires 11-30-2006
F0 LLI
Y8109
E
A
ICL
PAC
TS
HT DAD
ESNE
D
CE
ANI K
SI
A.US
TTIHR C
4" VERTICAL FACE
FLOW
EMBEDDING DETAILSCALE: N.T.S.
ANCHORING DETAILSCALE: N.T.S.
SILT FENCE DETAILSCALE: N.T.S.
ANGLE FIRST STAKE TOWARD PREVIOUSLY LAID BALE(2) REBAR, PICKETS OR
(2) 2"X2" STAKES DRIVEN 6" TO 12" INTO GROUND
WIRE OR NYLON BOND BALES PLACED ON CONTOUR OR AROUND STRUCTURE
GEOTEXTILE FABRIC
FABRIC ANCHORAGE TRENCH, BACK FILL W/ TAMPED NATURAL BOIL
FLOW
6''
6" MIN
METAL OR WOOD POST OR STAKE
NOTE: DEPENDING UPON CONFIGURATION ATTACH FABRIC TO STEEL POSTS W/ TIE WIRES, WOOD POSTS W/ NAILS.
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
ONTAE I
expires 11-30-2006
F0 LLI
Y8109
E
A
ICL
PAC
TS
HT DAD
ESNE
D
CE
ANI K
SI
A.US
TTIHR C
A-7
2
1
3
1'-4"
6" 10"
4'-0
"±
2'-0
"
8" 8"
10"
1'-4"
1'-0" 1'-0"
1'-9
"
7"L5"x3"x3/8" x5 1/2 LONG, W/ (2) 1/2" A325 BOLTS PER CONNECTION
1/41/4
3'-6
"
EQ
UA
L
1/4 2-12
C.L. "W" BEAM
GRATING (AS SHOWN ON PLAN)
TOE PLATE1/4"x4"xCONT.
EQ
UA
L
"W" SEE PLAN
HSS 2.375 x 0.154 STEEL POST@ 4'-0" O.C. MAX
HSS 1.66 x 0.14 STEEL RAIL
TYP.
TYP.
HSS 1.66 x 0.14 STEEL RAIL
3'-6
" (M
IN.)
VA
RIE
S2'
-0"(
MIN
.)
13'-9"
NEW SUUPORT CONCRETE PIER. (SEE PIER DETAILS ON THIS PAGE)
6'-4
"
3'-0
"3'
-4"
3'-5" 3'-5" 3'-5" 3'-5"
USE 1" STEEL GRATING "McNICOLS (SGW)" OR EQUAL (STANDARD BEARING BAR 1"x3/16" @ 15/16" O.C.)
4'-6"
2"
4'-6"
2"
4'-6"
13'-10"
W10x22
W10x22
W10x22
W10
x22
W10
x22
NEW (3) T-MOBILE EQUIPMENT CABINETS
PLINTH UNDER BTS CABINET (TYP.)
(2) L
5x5x
5/16
L5x5
x5/1
6
L5x5
x5/1
6
L5x5
x5/1
6
L5x5
x5/1
6
(2) L
5x5x
5/16
(2) L
5x5x
5/16
10"
2'-0
"
EQUIPMENT PLATFORM &STRUCTURAL NOTES
S-1
E
W
S
SW
SE
N
NW
NE
1 EQUIPMENT PLATFORM SCALE: 1/2" = 1'-0" (1/4"= 1'-0" IF 11X17 SHEET SIZE)
4.7 STEEL BAR GRATING SHALL BE STANDARD BEARING BAR GRATE TYPE GW-125 WITH 1 1/4"x3/16" @ 1 3/16" O.C. BEARING BARS AS MANUFACTURED BY McNICHOLS (1-800-237-3820) OR EQUAL. USE STANDARD J-BOLTS AND CLIPS FOR ATTACHMENT. GRATING SADDLE CLIP FASTENERS SHALL BE ASTM A570 GRADE 36 WITH MIN. THICKNESS OF 14 GA. SELF TAPPING GRATING FASTENERS BOLTS MIN. THICKNESS OF 14 GA. SELF TAPPING GRATING FASTENERS BOLTS SHALL BE STAINLESS STEEL PER ASTM A240, TYPE 410.
4.12 GRATING SHALL BE MIN. 1" x 3/16" WELDED STEEL WITH BEARING BARS AT 1 3/16" C.C, GALVANIZED, PROVIDE BANDING AT CUT EDGE OF BEARING BARS. GRATING SHALL BE SECURED TO STRUCTURAL STEEL WITH TYPE C SADDLE CLIPS, MIN. 14 GA, AND SELF TAPPING SCREWS. PROVIDE A MINIMUM OF 12 SADDLE CLIPS PER GRATING PANEL.
4.0 STRUCTURAL STEEL NOTES
4.8 GUARD RAILS, LADDERS AND STAIRS SHALL BE CONSTRUCTED IN ACCORDANCE WITH OSHA AND LOCAL REQUIREMENTS.
4.6 THERE SHALL BE NO FIELD CUTTING OF STRUCTURAL STEEL MEMBERS FOR THE WORK OF OTHER TRADES WITHOUT THE PRIOR APPROVAL OF THE STRUCTURAL ENGINEER.
4.5 ALL BEAMS SHALL BE FABRICATED WITH THE NATURAL CAMBER UP.
4.4 ALL WELDING SHALL BE DONE BY QUALIFIED WELDERS AND SHALL CONFORM TO LAWS D1.1 "STRUCTURAL WELDING CODE", LATEST EDITION. ALL WELDING ELECTRODES SHALL BE E70XX.
4.3 ALL BOLTS (OTHER THAN ANCHOR BOLTS), NUTS AND WASHERS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A325. ALL BOLTS SHALL BE 3/4 INCH DIAMETER, MINIMUM. BOLTS USED IN LATERAL LOAD RESISTING CONNECTIONS SHALL BE FRICTION TYPE, DESIGNED FOR INDICATED FORCES WITHOUT STRESS INCREASES.
4.2 ALL STRUCTURAL STEEL PLATES, SHAPES AND BARS SHALL CONFORM TO ASTM A36, UNLESS NOTED OTHERWISE. COLD FORMED TUBING SHALL CONFORM TO ASTM A500 GRADE B. PIPES SHALL CONFORM TO ASTM A53 GRADE B. ANCHOR BOLTS SHALL CONFORM TO ASTM A307 OR ASTM A36.
4.1 ALL STRUCTURAL STEEL WORK SHALL CONFORM TO THE AISC "SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS", LATEST EDITION, THE AISC "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES", LATEST EDITION.
4.10 MINIMUM SHEAR CAPACITIES: PROVIDE AT LEAST ONE HALF OF THE UNIFORM LOAD CARRYING CAPACITY OF THE BEAM WITH THE ASSUMPTION OF FULLY BRACED COMPRESSION FLANGE.
4.11 THE DEPTH OF A SIMPLE SHEAR CONNECTION SHALL NOT BE LESS THAN ONE HALF OF THE NOMINAL DEPTH OF THE BEAM. THE MINIMUM NUMBER OF BOLTS PER CONNECTION SHALL BE TWO (2).
4.9 A. ALL STEEL SHALL BE HOT DIPPED GALVANIZED. B. FIELD TOUCH UP ALL DISTURBED SURFACES WITH ZINC REACH PAINT. C. GRIND ALL WELDS ON HANDRAILS TO A SMOOTH FINISH.
3. ATTACH CABINETS DIRECTLY TO STRUCTURAL STEEL PER MANUFACTURER RECOMMENDATIONS BUT NOT LESS THAN ONE 1/2" Ø BOLT AT EACH CORNER.
4.13 STAIR TREADS SHALL BE ABLE TO SAFELY SUSTAIN 100 PSF LIVE LOAD OR A CONCENTRATED LOAD OF 300 LBS, APPLIED ON A 4 SQUARE INCHES AREA, WHICHEVER PRODUCES THE GREATER STRESSES.
6.0 SHOP DRAWINGS
6.1. SHOP DRAWINGS, UNLESS OTHERWISE NOTED, SHALL BE SUBMITTED FOR REVIEW PRIOR TO FABRICATIONS.
6.2. PRIOR TO SUBMITTAL, THE CONTRACTOR SHALL REVIEW THE SHOP DRAWINGS AND MAKE ANY CORRECTIONS REQUIRED. THE CONTRACTOR SHALL STAMP AND SIGN THE DRAWINGS THAT HE HAS REVIEWED THEM.
6.3. SHOP DRAWINGS SHALL BE FURNISHED FOR ALL STRUCTURAL COMPONENTS. ALL SUBMITTALS TO BE TWO (2) SETS PRINTS AND ONE (1) SET REPRODUCIBLES ONLY.
NOTES:
2. USE MASONRY BITS FOR DRILLING & NO CUTTING/DAMAGING OF REBARS IS ALLOWED
1. ALL EXISTING DIMENSIONS AND CONDITIONS MUST BE FIELD VERIFIED PRIOR TO FABRICATION
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
5 PIER ELEVATIONSCALE: 1/2" = 1'-0" (1/4"= 1'-0" IF 11X17 SHEET SIZE)
SECTIONSCALE: N.T.S.6 7 SECTION
SCALE: N.T.S.
1.1 DESIGN REQUIREMENTS PER 2003 INTERNATIONAL BUILDING CODE
2.6 EQUIPMENT CABINET WEIGHT (3) S12000: 53" W x 25" D x 75" H
WIND PRESSURE ON ANTENNAS & MOUNTING MEMBERSWIND PRESSURE ON PLATFORM
2.1 DEAD LOAD OF BAR GRATE
2.7 TRUST ON HANDRAILS
2.2 WIND PRESSURE
2.3 PLATFORM LIVE LOAD 2.5 SNOW LOAD
2.0 DESIGN LOADS
1.0 APPLICABLE CODES
10 PSF
1212 LBS
PER TIA/EIA-222-F
50 PLF HORIZONTAL & VERTICAL ON TOP RAILOR200 LB CONCENTRATED LOAD IN ANY DIRECTION
100 PSF30 PSF
30 PSF
3.5 THE CONTRACTOR SHALL INFORM THE ENGINEER IN WRITING OF ANY DEVIATION FROM THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL NOT BE RELIEVED OF THE RESPONSIBILITY FOR SUCH DEVIATION BY THE ENGINEER'S APPROVAL OF SHOP DRAWINGS, PRODUCT DATA, ETC., UNLESS THE CONTRACTOR HAS SPECIFICALLY INFORMED THE ENGINEER OF SUCH DEVIATION AT THE TIME OF SUBMISSION, AND THE ENGINEER HAS GIVEN WRITTEN APPROVAL TO THE SPECIFIC DEVIATION.
3.6 ALL THINGS WHICH, IN THE OPINION OF THE CONTRACTOR, APPEAR TO BE DEFICIENCIES, OMISSIONS, CONTRADICTIONS AND AMBIGUITIES, IN THE PLANS AND SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. PLANS AND/OR SPECIFICATIONS WILL BE CORRECTED, OR A WRITTEN INTERPRETATION OF THE ALLEGED DEFICIENCY, OMISSION, CONTRADICTION OR AMBIGUITY WILL BE MADE BY THE ENGINEER BEFORE THE AFFECTED WORK PROCEEDS.
3.1 STRUCTURAL DRAWINGS ARE INTENDED TO BE USED WITH ARCHITECTURAL AND ELECTRICAL DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE REQUIREMENTS OF ALL DRAWINGS INTO THEIR SHOP DRAWINGS AND WORK. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ENGINEER REVIEW.
3.2 NO CHANGE IN SIZE OR DIMENSION OF STRUCTURAL MEMBERS SHALL BE MADE WITHOUT THE WRITTEN APPROVAL OF THE ENGINEER. THE CONTRACTOR IS RESPONSIBLE FOR LIMITING THE AMOUNT OF CONSTRUCTION LOAD IMPOSED UPON STRUCTURAL FRAMING. CONSTRUCTION LOADS SHALL NOT EXCEED THE CAPACITY OF THE FRAMING AT THE TIME THE LOADS ARE IMPOSED.
3.3 THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. THE CONTRACTOR SHALL FURNISH ALL TEMPORARY BRACING AND/OR SUPPORTS REQUIRED AS THE RESULT OF THE CONTRACTOR'S CONSTRUCTION METHODS AND/OR SEQUENCES.
3.0 GENERAL NOTES
3.4 DO NOT SCALE THESE DRAWINGS, USE DIMENSIONS.
MEET OR EXCEED THE FOLLOWING CODES AND STANDARDS (LATEST EDITION) -DESIGN......................................................ACI 318 -CONSTRUCTION.....................................ACI 301 -DETAILING...............................................CRSI MANUAL OF STANDARD PRACTICE USE CLASS "B" FOR SPLICES UNLESS NOTED -REINFORCING STEEL.........................ASTM A615 GRADE 60, DEFORMED ASTM A706 IF BARS ARE TO BE WELDED -MIXING.......................................................ASTM C94. READY MIX CONCRETE -AIR ENTRAINMENT...............................ACI 318 AND ASTM C-260 -AGGREGATE...........................................ASTM C33 AND C330 (FOR LT. WEIGHT)
CONCRETE STRENGTH AT 27 DAYS SHALL BE 4000 PSI MINIMUM
DO NOT FIELD BEND OR WELD TO GRADE 60 REINFORCING STEEL.
PROVIDE IR ENTRAINED CONCRETE WITH AIR CONTENT OF 5 % TO 7%FOR ALL CONCRETE EXPOSED TO EARTH OR WEATHER.
MAXIMUM AGGREGATE SIZE: -3/4" FOR FOOTINGS, WALLS, BEAMS, SLABS AND COLUMNS. -3/8" FOR CONCRETE TOPPING.
DO NOT USE IN ADMIXTURE, WATER OR OTHER CONSTITUENTS OF CONCRETE WHICH HAS CALCIUM CHLORIDE.
MINIMUM COVER FOR REINFORCING STEEL UNLESS INCREASED COVER IS NECESSARY TO MEET FIRE RATING INDICATED: -CAST AGAINST AND EXPOSED TO EARTH...............................................3" -EXPOSED TO EARTH AND WEATHER #11 TO #6 BARS........................2" -EXPOSED TO EARTH AND WEATHER #5 AND SMALLER..............1 1/2" -INTERIOR EXPOSURE, BEAMS AND COLUMNS.....................................1 1/2" -INTERIOR EXPOSURE, SLABS, WALLS AND JOISTS...........................3/4"
5.0 CONCRETE NOTES
2 SECTIONSCALE: 3" = 1'-0" (1 1/2"= 1'-0" IF 11X17 SHEET SIZE)
SECTIONSCALE: 3" = 1'-0" (1 1/2"= 1'-0" IF 11X17 SHEET SIZE)3
SECTIONSCALE: 3" = 1'-0" (1 1/2"= 1'-0" IF 11X17 SHEET SIZE)4
SECTIONSCALE: 1" = 1'-0" (1"= 2'-0" IF 11X17 SHEET SIZE)8 9 SECTION
SCALE: 1/2" = 1'-0" (1/2"= 2'-0" IF 11X17 SHEET SIZE) 10 SECTIONSCALE: 1/2" = 1'-0" (1/2"= 2'-0" IF 11X17 SHEET SIZE)
EXP. 11-30-06
IS
ER
LI
M.OR
K
0NL
WA
YAAM
TAT
JJW
E F0
O
I
I
NE1
ARL
23
TUCST R
4
U
NUMBER G
CE
NE
DS
SLI
NIE
X
X
E-1
ELECTRICAL SITE PLAN
1 ELECTRIC & TELCO SITE PLAN SCALE:1"= 300' ( 1"=600' IF 11X17 SHEET SIZE)
AMPS INTERRUPTING CAPACITY
BASE TRANSMISSION SYSTEM
POWER PROTECTION CABINET
GLOBAL POSITIONING SYSTEM
PERSONAL COMMUNICATION SYSTEM
ELECTRICAL METALLIC TUBING
ABBREVIATIONS
PPCRIGID GALVANIZED STEEL
UNDERGROUND WATERSTORM SEWER
UNDERGROUND GAS
UWSS
RGSTYPUG
TYPICAL
DISC DISCONNECT SWITCHDRAWINGELECTRICAL
OVERHEAD
GENERATORGENGND
O/HGPS
PCS
GROUND
ELECDWG
EMT
BARE COPPER WIRE
AMERICAN WIRE GAUGE
BCW
CBTS
CABCONDUITCABINET
AICAWG
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
TESTS AND EXAMINATION WORK PRIOR TO THE
SERVICE CONDUIT LENGTH (TO PPC CABINET ONLY- EXCLUDING LENGTH FOR 1" CONDUITS TO BTS CABINETS)
TELCO
ELECTRIC
GROUNDING
METER IS REMOVED FROM THE SOCKET.
LABEL ALL ELECTRICAL EQUIPMENT PER T-MOBILE
PROVIDE T-MOBILE WITH ONE SET OF COMPLETE ELECTRICAL
SO THAT SERVICE WILL NOT BE INTERRUPTED WHEN A
ALL ABOVE GROUND CONDUITS AND BUSHING SHALL BE RGS.
DEVICES MUST INCLUDE HORN TYPE BY-PASS PROVISION ALL SINGLE- PHASE SELF- CONTAINED METER CONNECTION
"AS-BUILT" DRAWINGS AT THE COMPLETION OF THE JOBSHOWING ACTUAL ROUTINGS AND WIRING CONNECTIONS.
12.)
SPECIFICATIONS.
11.)
9.)
10.)
ORDERING OF THE ELECTRICAL EQUIPMENT AND
NEMA, NFPA, AND "UL" LISTED.
EQUIPMENT & DISCREPANCIES.
ELECTRICAL PLANS, DETAILS, AND DIAGRAMS ARE
THE AMOUNT AND LOCATION OF EQUIPMENT.
ENGINEER LISTING ALL MALFUNCTIONS, FAULTY
20,000 AIC WHERE APPLICABLE.
THE ENTIRE ELECTRICAL INSTALLATION SHALL BE GROUNDED
ALL CIRCUIT BREAKERS, FUSES AND ELECTRICAL EQUIPMENT
ALL MATERIALS SHALL BE MANUFACTURED IN ACCORDANCEWITH APPLICABLE STANDARDS ESTABLISHED BY ANSI,
SHALL HAVE A MINIMUM INTERRUPTING RATING OF
DAMAGED IN THE COURSE OF THE ELECTRICAL WORK.PATCH, REPAIR AND PAINT ANY AREA THAT HAS BEEN
AS REQUIRED BY UBC, NEC, T-MOBILE, AND ALL APPLICABLE
THE ACTUAL CONSTRUCTION. CONTRACTOR SHALLISSUE A WRITTEN NOTICE OF ALL FINDINGS TO THE
DIAGRAMMATIC ONLY. FIELD CONDITIONS DICTATE
LOCAL CODES.
7.)
8.)
6.)
4.)
5.)
NOTE:* THE CONDUIT LENGTH GIVEN IS BASED ON THE DRAWING +10'THE EXACT LENGTH TO BE VERIFIED IN FIELD. GC TO VERIFY LENGTHS AFTER COORDINATING W/ SERVICE UTILITY COMPANIES.
490' ±
490' ±
500' ±
FUSED DISCONNECT SWITCH
NEW UTILITY POLE
METER BASE
SYMBOLS
EXISTING UTILITY POLE
M
ALL ELECTRICAL MATERIALS, EQUIPMENT AND INSTALLATION PROCEDURES
NATIONAL ELECTRIC CODE, LATEST EDITION .
CONTRACTOR SHALL PERFORM ALL VERIFICATION
TO CONFORM WITH LOCAL JURISDICTION REQUIREMENTS.
GENERAL ELECTRICAL NOTES1.)
2.)
3.)
CODES AND STANDARDS
NATIONAL ELECTRICAL CODE
NATIONAL FIRE PROTECTION ASSOCIATIONUNDERWRITERS LABORATORIES, INC.INTERNATIONAL BUILDING CODEBUILDING OFFICIAL AND CODE ADMINISTRATORS
AMERICAN NATIONAL STANDARDS INSTITUTE
NEMA
ULNFPA
IBCBOCA
NECANSI
ENLARGED ELECTRIC & TELCO PLANSCALE: 3/8"=1'-0" (3/8"=2'-0" IF 11 X 17 SHEET SIZE)2
(1) NEW ELECTRICAL CONDUITS FROM PPC TO BTS CABINETS (APPROXIMATE DISTANCE= 30')
NEW CONDUIT STUB-UPS
NEW UTILITY RACK WITH NEW TELCO DEMARCATION, 200A 120/240V 1Ø,
3W METER SOCKET, LIGHT AND PPC CABINET, FURNISHED & INSTALLED
BY GC. (PPC CABINET TO BE FURNISHED BY T-MOBILE)
W
NW
SW
S
ENE
N
SE
NEW 6'-0" HIGH T-MOBILE ICE BRIDGE TO BE FURNISHED BY T-MOBILE & INSTALLED BY GENERAL CONTRACTOR.
NEW PRIMARY & FUTURE S12000 T-MOBILE OUTDOOR CABINETS,
FURNISHED BY T-MOBILE, INSTALLED BY GENERAL CONTRACTOR.NEW T-MOBILE 6'-4"X 13'-9"
STEEL PLATFORM TO BE FURNISHED & INSTALLED BY
GENERAL CONTRACTOR.
(6) NEW T-MOBILE PANEL ANTENNAS TO BE LOCATED AT
120' -0" CENTERLINE ELEVATION: FURNISHED BY
T-MOBILE & INSTALLED BY GENERAL CONTRACTOR
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
ONTAE I
expires 11-30-2006
F0 LLI
Y8109
E
A
ICL
PAC
TS
HT DAD
ESNE
D
CE
ANI K
SI
A.US
TTIHR C
GC TO ROUTE UNDERGROUND TELCO & ELECTRIC CONDUITS FROM EXISTING
UTILITY POLE/PEDESTAL TO PRIMARY BTS (TELCO) & TO NEW PPC CABINET (POWER).
GC TO ROUTE NEW BELOW GRADE ELECTRIC & TELCO UTILITIES USING
DIRECTIONAL BORING.
EXISTING MANHOLE
EXISTING PINE LINE
NEW 8-FTWIDE UTILITY EASEMENT
GC TO ROUTE UNDERGROUND TELCO & ELECTRIC CONDUITS FROM EXISTING
UTILITY POLE/PEDESTAL TO PRIMARY BTS (TELCO) & TO NEW PPC CABINET (POWER).
GC TO ROUTE NEW BELOW GRADE ELECTRIC & TELCO UTILITIES USING
DIRECTIONAL BORING.
W
NW
SW
S
ENE
N
SE
EXISTING GRAVEL
DRIVEWAY
EXISTING MANHOLE
EXISTING UNDERGROUND
SEWER LINE
EXISTING UTILITY POLE
EXISTING UTILITY POLE
EXISTING UTILITY POLE
EXISTING MANHOLE
EXISTING UNDERGROUND SEWER LINE
NEW 32'X40' T-MOBILE LEASE AREA
(1) NEW ELECTRICAL CONDUITS FROM PPC TO BTS CABINETS (APPROXIMATE DISTANCE= 25')
(1) NEW ELECTRICAL CONDUITS FROM PPC TO BTS CABINETS
(APPROXIMATE DISTANCE= 35')
NEW T-MOBILE STEEL LADDER TO BE FURNISHED
& INSTALLED BY GC
UTILITY DETAILS
E-2
ELECTRIC & TELCO SINGLE-LINE DIAGRAMSCALE: N.T.S.1
NOTES:1.) IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE PROPERTY OWNER & NECESSARY UTILITY COMPANIES FOR THE LOCATION OF ALL EXISTING BELOW GRADE UTILITIES PRIOR TO BEGINNING CONSTRUCTION SHALL BE RESPONSIBLE FOR ANY DAMAGE COSTS ASSOCIATED WITH EXISTING BELOW GRADE UTILITIES.2.) CONTRACTOR TO COORDINATE WITH UTILITY COMPANY FOR CONNECTION OF TEMPORARY AND PERMANENT POWER TO THE SITE. THE TEMPORARY POWER AND ALL HOOKUP COSTS TO BE PAID BY CONTRACTOR.3.) CONTRACTOR TO VERIFY LOCAL UTILITY REQUIREMENTS FOR DEPTH, SIZE & SEPARATION OF CONDUIT PRIOR TO INSTALLATION . NOTIFY CONSTRUCTION MANAGER IMMEDIATELY OF ANY DISCREPANCIES4.) CONTRACTOR TO CALL J.U.L.I.E. (800) 892-0123 48 HRS. PRIOR TO EXCAVATING FOR UNDERGROUND UTILITY LOCATIONS. SURROUNDING EXCAVATED AREA MUST BE PRIVATELY LOCATED FOR NONPUBLIC UTILITIES.
CONDUCTOR NOTES:1. ALL CONDUCTORS SHALL BE COPPER
2. ALL WIRING SHALL BE COPPER WITH THHN/THWN DUAL RATED 600 VOLTS INSULATION.3. CONDUCTORS SHALL BE 12 AWG MINIMUM UNLESS SPECIFICALLY NOTED OTHERWISE.4. GROUNDING CONDUCTORS SHALL BE SOLID TINNED COPPER UNLESS OTHERWISE NOTED.
SERVICE EQUIPMENT NOTES:1. SERVICE EQUIPMENT SHALL HAVE A SHORT CIRCUIT TO
WITHSTAND RATING THAT IS EQUAL TO OR EXCEEDS THE MAXIMUM AVAILABLE FAULT CURRENT AT THE SUPPLY TERMINAL. THE INSTALLATION SHALL BE FREE FROM ANY SHORT CIRCUITS AND GROUNDS.2. ALL ELECTRICAL EQUIPMENT SHALL BE ANCHORED TO WITHSTAND 80 M.P.H. WIND SPEED, EXPOSURE C.3. ALL ELECTRICAL EQUIPMENT SHALL BE LABELED WITH PERMANENT ENGRAVED PLASTIC LABELS.4. PATCH, REPAIR AND PAINT ANY AREA THAT HAS BEEN DAMAGED IN THE COURSE OF ELECTRICAL WORK.
CONDUIT NOTES:1. HWGC SHALL BE USED WHEN INSTALLED IN OR
UNDER CONCRETE SLABS, IN CONTACT WITH EARTH, OR EXPOSED ABOVE GRADE.2. EMT SHALL BE USED ONLY FOR INTERIORS RUNS AND SHALL HAVE COMPRESSION TYPE FITTINGS.3. SEAL TIGHT, FLEXIBLE CONDUIT MAY BE USED WHERE CODE PERMITS. ALL CONDUIT SHALL HAVE FULL SIZE EQUIPMENT GROUND WIRE.4. PVC SHALL BE SCH 405. SERVICE CONDUITS SHALL HAVE NO MORE THAN (3) -90° BENDS IN ANY SINGLE RUN. THE CONTRACTOR SHALL PROVIDE PULL BOXES AS NEEDED WHERE CONDUIT REQUIREMENTS EXCEED THESE CONDITIONS.6. SERVICE CONDUIT SHALL BE AT A MINIMUM DEPTH OF 42".7. ALL COAX, POWER AND TELEPHONE SYSTEM CONDUIT SHALL HAVE A MINIMUM 24" RADIUS SWEEPS TO EQUIPMENT, PULL BOXES, MONOPOLE, ETC., UNLESS OTHERWISE NOTED, OR AS REQUIRED BY UTILITY COMPANIES.
UTILITY COORDINATION NOTES:1. PROVIDE POWER AND TELEPHONE TO SERVICE POINTS PER
UTILITY COMPANY REQUIREMENTS. CONTRACTOR SHALL CONTACT UTILITY SERVICE PLANNERS AND OBTAIN ALL SERVICE REQUIREMENTS AND INCLUDE COSTS FOR SUCH IN HIS BID.2. CONTRACTOR TO COORDINATE WITH UTILITY COMPANY FOR CONNECTION OF TEMPORARY AND PERMANENT POWER TO HE SITE. THE TEMPORARY POWER AND ALL HOOKUP COSTS TO BE PAID BY CONTRACTOR.3. PROVIDE DAILY UPDATES TO PM UNTIL FINAL ELECTRICAL SERVICE IS EFFECTED.
CONDUIT MATERIAL SCHEDULE:UNLESS NOTED OTHERWISE, ALL CONDUIT RUNS SHALL CONFORM TO THE FOLLOWING :1.) ALL ABOVE GRADE, EXTERIOR CONDUITS SHALL BE RGS.2.) ALL BELOW GRADE HORIZONTAL CONDUITS SHALL BE PVC 3.) ALL BELOW GRADE 3" Ø & 45" BENDS SHALL BE PVC W/THREADED CONNECTIONS.4.) ALL BELOW GRADE TO ABOVE GRADE RISERS SHALL BE PVC W/THREADED CONNECTIONS.5.) SEAL TIGHT FLEXIBLE CONDUIT MAY BE USED WHERE CODE PERMITS.
CONTRACTOR TO FURNISH AND INSTALL ALL CIRCUIT BREAKERS TYPE " SQUARE - D" HACR, MINIMUM 22,000 AIC RATING
TOTAL = 26.18 KVA = 109 AOTHER = 24.78 KVALIGHTING = 0.0 X1.25 = 0.0 KVA
NOTE:
4.13
0.4
LOADS PER PHASE
PANEL 'L'
GFI RECEPTACLE = 1.4 KVA
TYPE: 22,000 AIC
VOLTAGE: 120/240 1 PHASE
TOTALS
- - -
- - -
BTS 3
BTS 2
REMARKS
4.13
-6 - 7
-
26
6
26
-
5
3
60
160
16.52 9.66
4.13
4.13
4.13
4.13
1. Ø
CIR
CU
IT
PO
LES
WIR
E
AMPS
BREAKER
A B
BUS: 200 A
TELCO GFI RECEPTACLE12
6
6
8 20 --
6 20
4 90
2 60
1
-
2
SERVICE LIGHT
PRIMARY BTS
SERVICE LIGHT
WIR
E
MOUNTING: SURFACE
LOCATION: PPC MINI CABINET
AMPS
CIR
CU
IT
PO
LES
BREAKER REMARKS
NOTES:1. ALL CONDUITS & CONDUCTORS FURNISHED AND INSTALLED BY CONTRACTOR UNLESS NOTED OTHERWISE.2. SEE SINGLE-LINE DIAGRAM FOR UTILITY CONDUITS & CONDUCTOR SIZES.3. ALL UTILITY LOCATIONS AND CONNECTIONS TO BE VERIFIED WITH T-MOBILE REPRESENTATIVE. 4. BELLOW GRADE CONDUITS FROM PPC-CABINET TO BE RGS FROM ELBOW TO STUB-UP.
NEW T-MOBILE NEMA 3R, 200 AMP OUTDOOR POWER DISTRIBUTION CENTER (PPC)
FINISHED GRADE
A A A
RISER DIAGRAM LEGEND:B
E
CD
F
(1) 1/2" RGS FOR ALARM
(1) 2" RGS w/ (3) 3/Ø, (1) #4 AWG CU. THHN
(3) 1" RGS w/ (3) #6 AWG CU. THHN & (2) PULL STRINGSA
(1) 1/2" CONDUIT w/ #6 AWG SERVICE GROUND
ELECTRICAL CONDUITS SHALL TRANSITION TO SEALTIGHT AT BTS BASE ENTRY TO PREVENT WIRING CONTACT WITH CONCRETE AND SHARP CABINET EDGES. GC TO CAP & SEAL ALL FUTURE CONDUITS. ALL MATERIALS FURNISHED & INSTALLED BY GC
MATERIALS NOTES:
(1) 4" RGS w/ (6) 6 PAIRS TELCO & (2) PULL STRINGS
GC TO FURNISH & INSTALL ALARM CABLES BETWEEN PPC & PRIMARY BTS CABINETS
ROUTE RGS SCH. 40 CONDUIT BELOW GRADE FROM THE PPC TO THE TO THE DISCONNECT -- ALL CONDUITS BELOW PAVED SURFACED SHALL BE SCH. 80. ALL EXPOSED EXTERIOR CONDUITS SHALL BE RGS SCH. 40 AND INTERIOR CONDUITS (I.E. ROOFTOPS) MAY BE SUBSTITUTED BY EMT.
TELCO SHALL BE 6-PAIR SHIELDED 24 AWG WIRE, ROUTE FROM THE NEW SMART JACK AND JUNCTION BOX FRAME TO PRIMARY BTS.
D
F
EXISTING SERVICE POLE w/ OVERHEAD SERVICE & TRANSFORMER
OVERHEAD ELEC./TELCO
(1) 6" RGS w/ 350MCM, (1) #4 AWG CU. THHN - see note D
(1) 4" RGS w/ (6) 6 PAIRS TELCO & (2) PULL STRINGS
B
C
D
E
F
G
A
B
C
DCONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING & VERIFYING THE TYPE OF ELECTRICAL SERVICE AS WELL AS THE ACTUAL CONDUIT DISTANCE TO SERVICE POINT -- GC TO NOTIFY ENGINEER OF DISCREPANCIES IMMEDIATELY -- OTHERWISE CONTRACTOR SHALL BE RESPONSIBLE FOR SIZING PHASE CONDUCTORS FROM THE SERVICE POINT TO LOAD CENTER IN ORDER TO COMPLY WITH THE LOCAL BUILDING/ELECTRICAL CODE AS WELL AS THE NEC AND UTILITY COMPANY REQUIREMENTS
E
GC IS RESPONSIBLE FOR COORDINATING & VERIFYING SERVICE CONNECTION POINT AND TELCO DEMARC INSTALLATIONF
GC TO FURNISH & INSTALL NEW SERVICE GROUND @ METER LOCATION IN COMPLIANCE WITH LOCAL ELECTRICAL, NEC & ELECTRICAL UTILITY REQUIREMENTS. GC SHALL AT A MINIMUM INSTALL #6 AWG GROUND WIRE CONNECTED TO A NEW 5/8" COPPER CLAD GROUND ROD
G
PRIMARY BTS CABINET
BTS CABINET #2(FUTURE)
BTS CABINET #3 (FUTURE)
F
FOR LOCATIONS OF SERVICE POINTS - SEE SHT. LS-1
LOOP MIN. 15' SLAG UP SERVICE POLE FOR UTILITY SERVICE CONNECT - ENCLOSE IN POLE PROTECTOR
NEW T-MOBILE 200 AMP, 120/240V, 1Ø, 3W METER SOCKET & DISCONNECT ON NEW H- FRAME
NEW UTILITY H-FRAME FOR T-MOBILE, SEE SHEET E-3 FOR MORE DETAIL.
NEW 200 AMP, 120/240V, 1Ø, 3W NEMA 3R DISCONNECT
G
DISC.200A
SWITCHMETER
8"X10"X12" NEMA 3R PULL BOX
TELCO SMARTJACK INSIDE ENCLOSURE
NEW 8"X10"X12" NEMA 3R PULL BOX FOR FUTURE TELCO BOX
2" CONDUIT BETWEEN PULL BOXES
TO PPC
ATTENTION GC:1.) CONTRACTOR TO COORDINATE WITH UTILITY COMPANY FOR CONNECTION OF TEMPORARY AND PERMANENT POWER TO THE SITE. THE TEMPORARY POWER AND ALL HOOKUP COSTS TO BE PAID BY CONTRACTOR.2.) CONTRACTOR TO VERIFY LOCAL UTILITY REQUIREMENTS FOR DEPTH, TYPE, SIZE & SEPARATION OF CONDUIT PRIOR TO INSTALLATION . NOTIFY CONSTRUCTION MANAGER IMMEDIATELY OF ANY DISCREPANCIES3.) CONTRACTOR TO CALL UTILITY LOCATE HOTLINE 48 HRS. PRIOR TO EXCAVATING FOR UNDERGROUND UTILITY LOCATIONS. SURROUNDING EXCAVATED AREA MUST BE PRIVATELY LOCATED FOR NONPUBLIC UTILITIES. 4.) ALL ABOVE GRADE OR WEATHER EXPOSED CONDUITS SHALL BE OF RIGID GALVANIZED CONDUIT!
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
ONTAE I
expires 11-30-2006
F0 LLI
Y8109
E
A
ICL
PAC
TS
HT DAD
ESNE
D
CE
ANI K
SI
A.US
TTIHR C
NEW 10-FT RGS SLEEVE ALONG EXISTING POLE
NEW EQUIP. PLATFORM
UTILITY DETAILS
E-3
JOINT UTILITY TRENCH DETAIL1 SCALE: N.T.S.
4"
1'-0
"
3'-6
" MIN
.
SECTION FOR USE UNDER GRASS OR BARE GROUND AREAS
SAND
TELCO CONDUITSEE DWG. E-2 FOR SIZE
ELECTRICAL CONDUIT SEE DWG. E-2 FOR SIZE
12"
CRUSHED LIMESTONE OR GRAVEL
NATIVE SOIL, COMPACTED AS REQUIRED TO PREVENT SETTLEMENT
RESTORE SURFACE COURSE AND BASE COURSE MATERIAL ORIGINAL CONDITION
6" WIDE UTILITY WARNING TAPE (8" TO 12" BELOW GRADE) ENTIRE LENGTH OF TRENCH.
SECTION FOR USE UNDER PAVEMENT OR VEHICLE TRAFFIC AREAS
CONTRACTOR TO VERIFY LOCAL UTILITY REQUIREMENTS FOR DEPTH, SIZE & SEPARATION OF CONDUITS PRIOR TO INSTALLATION. NOTIFY CONSTRUCTION MANAGER IMMEDIATELY OF ANY DISCEPANCIES.
2.) CONTRACTOR TO CALL UTILITY LOCATES 48 HRS PRIOR TO EXCAVATING FOR UNDERGROUND UTILITY LOCATIONS. LOCATION SURROUNDING EXCAVATED AREA MUST BE PRIVATELY LOCATED FOR NON-PUBLIC UTILITIES.
NOTE:1.)
HE
IGH
T V
ER
IES
, SE
E S
HE
ET
A-2
FO
R M
OR
E IN
FO3'
-6"
3" C
LEA
RA
NC
E
3 WAVEGUIDE POST DETAILSCALE: N.T.S.
1'-3"
12" Ø MIN. CONCRETE PIER.
FINISH SLOPE TO DRAIN
10"
DIAMOND GRIP CHANNEL 2'-0" WIDE ATTACHED WITH J BOLTS
DEPENDING ON ENTRY PORTHEIGHT, FIELD VERIFY)
(PIPE LENGTH MAY VARY3" DIA. (MIN) SCH 40 PIPE
WAVEGUIDE BRIDGE HANGER KIT ANDREW OR APPROVED EQUAL AT 36" O.C. MAX.
8"
MOUNTING BRACKET
GALV. STEEL U-BOLTS WITH LOCK WASHERS
ANDREW OR EQUAL
GALV. STEEL PIPE CAPWAVE GUIDE BRIDGE
3"Ø GALVANIZED STEEL PIPE SCH. 40
6'-0"
3R BREAKER BOX PLAN VIEW DETAIL SCALE: N.T.S.2
NEW NEMA 3R BREAKER BOX WITH 3X60 AMP BREAKERS
NEW POWER METER
UNISTRUT FOR CONDUITS
NEW 12" DIA. CONCRETE SUPPORT PIERS W/42" MIN. DEPTH BELOW GRADE
12"
3R BREAKER BOX (FRONT ELEVATION VIEW) 4 SCALE: N.T.S.
6'-0
"
NEW T-MOBILE POWER
DISTRIBUTION CABINET
NEW POWER METER
UNISTRUT FOR CONDUITS
NEW 12" DIA. CONCRETE
SUPPORT PIERS W/42" MIN. DEPTH
BELOW GRADE
3"Ø GALVANIZED STEEL PIPE SCH. 40
3'-6
" MIN
. OR
FR
OS
T LI
NE
NEW 12" DIA. CONCRETE SUPPORT PIERS W/42" MIN. DEPTH BELOW GRADE
6
CONDUIT TO BTS CABINETS
2"
UNISTRUT FOR CONDUIT SUPPORTUSE APPROVED CONDUIT CLAMPS
CONDUIT FROM UTILITY SERVICE POINTS
"U" BOLT UNISTRUT TO VERTICAL PIPES
3"Ø GALVANIZED STEEL PIPE SCH. 40
1/2" Ø CONDUIT FROM 2Ø AMP BREAKER IN PPC TO LIGHTS
NEW T-MOBILE POWER DISTRIBUTION CABINET, FURNISHED BY T-MOBILE & INSTALLED BY GC.
3" C
LEA
RA
NC
E
3'-6
" MIN
. OR
FR
OS
T LI
NE
12"
UTILITY RACK ELEVATION DETAIL SCALE: N.T.S.
2"
6'-0"
NEW GENERATOR RECEPTACLE
6'-0"
3'-6
" MIN
. OR
FR
OS
T LI
NE
METER &TELCO H-FRAME ( REAR ELEVATION VIEW )
12"
SCALE: N.T.S.5
2"
CONDUIT TO PPC CABINET
3"Ø GALVANIZED STEEL PIPE W/ CAP SCH. 40
"U" BOLT UNISTRUT TO VERTICAL PIPES
POWER METER BASE WITH DISCONNECT
3"
CROUSE-HINDS LIGHT FIXTURE WITH 150 WATTS LAMP SIZE MIN. (TYP. OF 2)
6'-0
"
P1000 UNISTRUT 1-5/8" FOR CONDUIT SUPPORT
CONDUIT FROM UTILITY SERVICE POINTS
NEW 12" DIA. CONCRETE SUPPORT PIERS W/42" MIN. DEPTH BELOW GRADE
3"Ø TELCO CONDUIT TO PRIMARY BTS W/ 1/4" PULL ROPE AND (3) 6 PAIR.USE APPROVED CONDUIT CLAMPS
8"X10"X12" NEMA 3R PULL BOX
2"Ø CONDUIT CONNECTING PULL BOXES
4"Ø TELCO CONDUIT FROM TELCO SOURCE W/ 1/4" PULL ROPE AND (6) 6 PAIR.
TELCO SMARTJACK INSIDE ENCLOSURE
(3) 3/4" Ø SEALTITE(1) 1" SEALTITE &
3'-0
"
16"
3"12
"
*
TO MATCH WITH ELECTRIC METER OR PPC CABINET SUPPORT-CONSULT W/SPECIFIC MFR. CUT SHEETS
*
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
ONTAE I
expires 11-30-2006
F0 LLI
Y8109
E
A
ICL
PAC
TS
HT DAD
ESNE
D
CE
ANI K
SI
A.US
TTIHR C
NEW TELCO BOX
_dwgs0610S7S2-W_dwgCS7S2-W
POWER DISTRIBUTION PANEL LOAD DETAILCB # LOAD CENTER # DESCRIPTION
12
3
45
6
-
-
1 & 35 & 7
9 & 11
2 & 4
6 & 810
12
EMERGENCY PWR MAIN
UTILITY PWR MAIN
PRIMARY BTS
BTS # 2 BTS # 3
BLANK
BLANK
SERVICE LIGHTGFI SERVICE RECEPTACLE
gs061005_1.jpg
PPC CABINET DETAILS & BTS INSTALLATION
LAYOUT DETAIL
E-42 SCALE: N.T.S.
CABINET AND BASE LAYOUT DETAILS
53 in (1.35 m)
75 in HEIGHT
WIDTH
2
240 V +/- 10%
25 in (.65 m)
1.80 M
22100 BTU/HOUR
11006 BTU/HOUR
50 A
6500 W
3238 W
DEPTH
FOOTPRINT
VOLTAGE
MAXIMUM WEIGHT
EMPTY WEIGHT
MAIN CIRCUIT PROTECTION
NORMAL HEAT DISSIPATION
MAX. POWER (240V )
MAX. HEAT DISSIPATION
NORMAL POWER
396 lb
1212 LB
20 MCM
-40° to 112° F(-40° to 50° C)
65 DB
100%
38.0 DBM
40.3 DBM
-108 DBM
HUMIDITY
GROUND CABLE
OPERATING TEMPERATURE
MAXIMUM OPERATING
CONNECTOR (H2D)
ANTENNA CONNECTORS
CABINET OUTPUT
RECEIVE SENSITIVITY
OUTPUT PWR AT CAB. ANTENNA
MAX LEVEL OF ACOUSTIC NOISE
1. CONTRACTOR TO SUPPLY ALL HARDWARE AND CONDUCTORS NECESSARY TO BRING A 240 V, 50 AMP SERVICE INTO THE CABINET AND CONNECT THE MAIN.
2. CONTRACTOR IS RESPONSIBLE FOR BONDING THE GROUNDING CONDUCTOR FROM THE CABINET TERMINAL TO THE MASTER GROUND BAR.
3. CONTRACTOR SHALL VERIFY THE ARRANGEMENT OF THE AC MAIN PRIOR TO INSTALLATION OF SERVICE IN THE EVENT THE MODULE IS RECONFIGURED.
4. THE ENTRY PORT USED FOR THE INSTALLATION OF THE POWER AND TELEPHONE ENTRANCE WILL BE SEALED WITH A SILICONE SEALANT AFTER INSTALLATION.
5. CONTRACTOR SHALL MOUNT THE CABINET TO THE BASE UNIT WITH HARDWARE SUPPLIED WITH NORTEL COMPLETION KIT # NTQA70GA, AND SUPPLY THE HARDWARE NEEDED TO ATTACHED THE BASE TEMPLATE AND BASE TO THE MOUNTING PLATFORM.
6. SPECIAL CARE WILL BE TAKEN TO ENSURE AN 8' VERTICAL CLEARANCE ABOVE MOUNTING PLATFORM TO ALLOW FOR MAINTENANCE OF THE BATTERIES AND HVAC UNIT.
7. CONTRACTOR SHALL DETERMINE THE BEST-FIT LOCATION FOR THE POWER AND TELCO ENTRANCES INTO THE BASE UNIT.
8. CONTRACTOR SHALL VERIFY WITH T-MOBILE PROJECT MANAGER TO OBTAIN LATEST MANUFACTURER DRAWINGS & CABINET SPECIFICATIONS.
1. CONTRACTOR RESPONSIBLE FOR OFF LOADING THE CABINET UPON DELIVERY.
2. CONTRACTOR RESPONSIBLE FOR RF CABLING TO THE COMBINERS, RF CABLE SHALL BE COLOR CODED AT THE COMBINER, OUTSIDE OF CABINET, AT TOWER (OR AT CABLE TRAY CONVERGENCE) AND AT ANTENNA.
3. CONTRACTOR IS RESPONSIBLE FOR MOUNTING THE TELCO AND ALARM DEMARCATION BLOCKS AFTER COAX IS PULLED AND CONNECTING PHONE LINE FROM THE SMART JACK.
4. CONTRACTOR IS RESPONSIBLE FOR INSTALLING ROX BOX.
1. 1.5 HOURS OF BATTERY BACKUP IS PROVIDED FOR FULL TRX OPERATION. AN ADDITIONAL 0.5 HOURS IS PROVIDED TOR THE BCF WITHOUT TRX OPERATION.
2. MAXIMUM IS DEFINED AS BATTERIES CHARGING AND HEATERS ACTIVE. AUXILLARY 110 V OUTLET POWER MUST BE ADDED TO THE FIGURE.
3. NORMAL IS DEFINED AS BATTERIES NOT CHARGING AND HEATERS NOT ACTIVE.
TELCO ENTRY
SEE NOTE 7
SEE NOTE 7
POWER ENTRY
INSTALLATION
ROX BOXINTERNAL BATTERIES
CLIMATE UNITS (2 TOTAL)
AC MAIN
HINGED TOP COVER
AIR OUTLET
AIR INLET
THIS SHEET
INFORMATIONDRAWINGS FOR ADDITIONAL
INTERNAL COMPONENTS, SEENORTEL SHOP
AMPLIFIERS
COMBINERS
9' M
IN.
CLE
AR
AN
CE
LEFT DOOR
75" H
SEE DETAIL,
POWER ENTRY
SEE NOTE 753.2"FRONT6"
45.1" 10"
PLATES
UNIVERSAL
HARDWARE
10"
SEE NOTE 7
TELCO ENTRYINSIDE WITH SUPPLIED
HERE, ATTACH ON
REPLACE SIDE PLATE
NOTE: USE SUPER-FLEX 1/2"
JUMPERS FROM CABINET,
MAX FROM ROX BOX
EXTEND JUMPERS 6" TO 8"
FRONT
NOTES:
NOTES:
S12000 SPECIFICATION TABLE
NOTES:
1 SCALE: N.T.S.PPC CABINET DETAILS
53 in (1.35 m)
63 in (1.6 m) HEIGHT
WIDTH
2
240 V +/- 10%
25 in (.65 m)
1.80 M
22100 BTU/HOUR
11006 BTU/HOUR
50 A
6500 W
3238 W
DEPTH
FOOTPRINT
VOLTAGE
MAXIMUM WEIGHT
EMPTY WEIGHT
MAIN CIRCUIT PROTECTION
NORMAL HEAT DISSIPATION
MAX. POWER (240V )
MAX. HEAT DISSIPATION
NORMAL POWER
326.2 lb (148 kg)
1058 LB
20 MCM
-40° to 112° F(-40° to 50° C)
65 DB
100%
38.0 DBM
40.3 DBM
-108 DBM
HUMIDITY
GROUND CABLE
OPERATING TEMPERATURE
MAXIMUM OPERATING
CONNECTOR (H2D)
ANTENNA CONNECTORS
CABINET OUTPUT
RECEIVE SENSITIVITY
OUTPUT PWR AT CAB. ANTENNA
MAX LEVEL OF ACOUSTIC NOISE
S8000 SPECIFICATION TABLE
60.0
25.0
29.5
9.1
25.020.0
50.8
60.0
5.7
21.8
GFCIINTERNAL
RECEPTACLELOCATION
FOR MOUNTING HOLE LOCATION
CENTER PONCH FOR
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
ONTAE I
expires 11-30-2006
F0 LLI
Y8109
E
A
ICL
PAC
TS
HT DAD
ESNE
D
CE
ANI K
SI
A.US
TTIHR C
X X X X X X X
X X X X X X X
NEW #2 SOLID, TINNED CU GROUND WIRE(TYP)
CU GROUND WIRE#2/0 GREEN INSULATED
STRUCTURETOWER
FOR EACH COAX GROUND KIT#6 INSULATED WIRES ONE
CU GROUND WIRE#2/0 GREEN INSULATED
FOR EACH COAX GROUND KIT#6 INSULATED WIRES ONE
CONNECT END OF LINE GROUND KITS
TO NEMA
#2 SOLID TINNED GROUND WIRETO GROUND RING, 2 LEADS EACHCONNECTION FROM BTS CADWELDED
TINNED CU GROUND WIRENEW #2 SOLID,
NEW T-MOBILE #2 SOLID,
TO EXISTING SYSTEM
TINNED GROUND WIRE EXOTHERMICLY WELDED
(TYP)
GROUND RODS 5/8" X 10'NEW T-MOBILE COPPER CLAD
3R BREAKERBOX
NEW T-MOBILE
LOWER BUSS
BARS COPPER BUSSTINNED
SPECIFICATIONSAS REQUIRED BY T-MOBILE
EXOTHERMICLYWELDED TO GROUND ROD
CU GROUND WIRE
NEW T-MOBILE #2
CONNECT TO TELCO SERVICE POINT AS REQUIRED
CONNECT TO ELECTRICAL SERVICE POINT PER NATIONAL ELECTRIC CODE
SOLID, TINNED
PVC SLEEVE TOBELOW GRADE
TO LIGHTING ROD
TINNED GROUND WIRE EXOTHERMICLY WELDEDTO EXISTING SYSTEM
NEW T-MOBILE #2 SOLID,
CONNECT TOMONOPOLE FLANGE
#6 LEADS TO COAX GROUND KITS
A-1 B-1 C-1
MONOPOLE SYSTEM GROUNDING DETAILSCALE: N.T.S.2
EG-1
SITE GROUNDING PLAN
FUTURE CONNECTION (10 FT.)
CADWELD OR T-MOBILE APPROVED CONNECTION
GROUND BAR
NOTE: CONTRACTOR SHALL REVIEW SOIL RESISTIVITY REPORT FOR SPECIFIC GROUNDING SYSTEM RECOMMENDATIONS (i.e. XIT GROUND REQUIREMENTS).
5. SPARE LEADS TO GROUND RING FOR FUTURE CABINETS. NOT LESS THAN 4 FEET AND NOT MORE THAN 5 FEET LONG - COILED NEATLY NEAR FUTURE BTS POSITION6. #4 AWG INSULATED STRANDED GROUND WIRE FROM MONOPOLE BOTTOM GROUND BAR TO DESIGNATED SECTOR GROUND BAR AT
3.ATACH TO EXISTING GROUND RING IN FOUR DIFFERENT PLACES SEPARATE EACH CONNECTION BY 3'4. CONNECTIONS FOR POWER CABINET AND BTS - PROVIDE 1 LEAD FOR EACH CABINET (NOT LESS THAN 4 FEET AND NOT MORE THAN 5 FEET
2. FENCE GROUNDING AT ALL CORNER POSTS (CADWELD CONNECTION FROM GROUND RING TO FENCE POST AT CORNERS (CONNECTION TO BE NO
SYMBOLS LEGEND:GROUND WIRE (ABOVE GRADE)
GROUND WIRE (BELOW GRADE)
XIT GROUND ROD
SPARE GROUND WIRE FORGROUND ROD WITH ACCESS
GROUND ROD
(TEST WELL)
LONG TO BE COILED UNDER PLATFORM - FOR USE AND FUTURE USE).
MORE THAN 12 INCHES ABOVE GROUND BUT MUST BE VISIBLE).
1. COPPER CLAD GROUND ROD AS SPECIFIED ABOVE.
TOP OF MONOPOLE
ALL GROUND LEADS DENOTED BY ( ) SHALL BE INSTALLED IN 1/2" SCHEDULE 40 PVC ABOVE GRADE.
ALL CONNECTIONS TO THE GROUND RING, AND PERIPHERAL EQUIPMENT WILL BE MADE VIA CADWELD PROCESS UNLESS OTHERWISE SPECIFIED.GROUND RODS WILL BE 5/8" X 10 FOOT COPPER CLAD NOT LESS THAN 10 FOOT OR MORE THAN 15 FOOT APART.
ALL WIRING USED IN THE GROUND RING SHALL BE #2 SOLID TINNED COPPER UNLESS OTHERWISE SPECIFIED.
GROUNDING NOTES:
RAW LAND
7. FOR WOOD FENCE APLICATIONS NO GATE OR CORNER POST GROUNDS ARE REQUIRED
#2 SOLID, TINNED BARE COPPER GROUND WIRE FROM NEW GROUND RING TO EXISTING GROUND RING W/ VS TYPE CADWELD ( 2 REQUIRED).
6
#2 SOLID TINNED COPPER WIRE FROM GROUND BAR IN PLINTH TO COLLECTION GROUND BAR ( 2 REQUIRED). TYPICAL FOR EACH BTS CABINET.
PLINTH GROUND BAR (SUPPLIED W/ PLINTH)
9
8
7
#2 SOLID, TINNED BARE COPPER GROUND WIRE FROM LOWER TOWER GROUND BAR TO NEW GROUND RING ( 2 REQUIRED).
LOWER TOWER COPPER GROUND BAR
5/8" Ø X 10'-0" COPPER CLAD GROUND ROD
GROUND RING, #2 SOLID, TINNED BARE COPPER WIRE. CONSTRUCT RING FROM ONE CONTINUOUS PIECE.
2
GROUND SYSTEM TEST WELL
5
4
3
KEY NOTES:1
#6 AWG STRANDED INSULATED GROUND WIRE FROM GROUNDING KIT TO GROUND BAR ( TYPICAL ALL CABLES)
#2 SOLID, TINNED BARE COPPER GROUND WIRE FROM GROUND BAR TO GROUND RING ( 2 REQUIRED)
COPPER GROUND BAR ATTACHED TO ICE BRIDGE
#2 SOLID TINNED, BARE COPPER GROUND WIRE FROM UTILITY POST TO GROUND RING14
#2 SOLID TINNED, BARE COPPER GROUND WIRE FROM PPC MINI CABINET TO GROUND RING
#2 SOLID, TINNED BARE COPPER GROUND WIRE, BOND ICE BRIDGE POST W/ VS TYPE CADWELD. (1 PER POST REQUIRED).
#2 SOLID, TINNED BARE COPPER GROUND WIRE FROM ICE BRIDGE TO ICE BRIDGE POST.
EXISTING GROUND RING12
13
11
10
16
17
15
18
19
20
#2 SOLID, TINNED BARE COPPER GROUND WIRE FROM H-FRAME POST TO GROUND RING.
#2 SOLID, TINNED BARE COPPER GROUND WIRE FROM GROUND RING TO TELCO BOX.
#2 SOLID, TINNED BARE COPPER GROUND WIRE FROM GROUND RING TO METER SOCKET.
1 ENLARGED SITE GROUNDING PLANSCALE: 1/4" = 1'-0" (1/4" = 2'-0" IF 11 X 17 SHEET SIZE)
UPPER TOWER COPPER GROUND BAR
#2 SOLID, TINNED BARE COPPER GROUND WIRE FROM GROUND RING TO FENCE POLE.
21
E
W
S
SW
SE
N
NW
NE
#2 SOLID, TINNED BARE COPPER GROUND WIRE FROM NEW GROUND RING TO EXISTING GROUND RING (2 REQUIRED).
22
2(TYP.)
NOTE:GROUND BUSS BAR: GC TO INSTALL COPPER GROUND BUSS BAR AT THE END OF THE ICE BRIDGE AT A LOCATION ADJACENT TO THE PRIMARY BTS. BUSS BAR SHALL BE CONNECTED TO GROUND RING WITH TW #2 AWG SOLID TINNED COPPER LEADS. ALL EXPOSED GROUND LEADS SHALL BE ENCASED IN 1/2" FLEXIBLE SEAL TIGHT CONDUIT AND SEALED W/ SILICONE AT EACH END.
1
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
ONTAE I
expires 11-30-2006
F0 LLI
Y8109
E
A
ICL
PAC
TS
HT DAD
ESNE
D
CE
ANI K
SI
A.US
TTIHR C
#2 AWG STRANDED WIRE w/BLACK JACKET FROM FENCE GATE TO FENCE POST
23
3
4
5
7
8 (TYP.) 9
10 (TYP.) 11 (TYP.)
13
15
1617
20
19
18
21
23(TYP.)
(TYP.)
24 #2 SOLID, TINNED BARE COPPER GROUND WIRE FROM STEEL FRAME TO GROUND RING
24(TYP.)
PARALLEL THROUGH CONNECTION OF HORIZONTAL CABLES
TYPE PT
TYPE GT
THROUGH CABLE TO TOP OF GROUND ROD
HORIZONTAL SPLICE
SPLICE OF HORIZONTAL CABLES
PARALLEL HORIZONTAL CONDUCTORS
THROUGH CABLE TO GROUND ROD
CABLE DOWN AT 45 ° TO RANGE OF VERTICAL PIPES
TYPE VS
VERTICAL PIPE
CABLE DOWN AT 45 ° TO VERTICALSTEEL SURFACE INCLUDING PIPE
VERTICAL STEEL SURFACE
TYPE VS
TWO HOLE - LONG BARREL LENGTH
TYPE YA-2
COPPER LUGS
BOND JUMPER
TYPE 2-YA-2
FIELD FABRICATEDGREEN STRANDED INSULATED
CADWELD CONNECTIONSOR APPROVED EQUAL
TO FLAT STEEL SURFACE OR HORIZONTAL PIPE
HORIZONTAL STEEL SURFACE
TYPE HS
"C" CONNECTOR
TYPE YGHC
HYPRESS
BURNDY CONNECTIONSOR APPROVED EQUAL
CADWELD DETAILSSCALE: NTS1
LOWER TOWER BUSS & BTS GROUNDING DETAIL SCALE: NTS54 GROUND BAR DETAIL
SCALE: NTS
GROUNDING AT BOTTOM OF MONOPOLESCALE: NTS2
FINISHED GRADE
COPPER WIRE#2 SOLID TINNED
TO GROUND RING (TYP.)
COPPER WIRE
(2 PLACES TYP.)
T/FOUNDATION
#2 SOLID TINNED
TO GROUND RING (TYP.)
HS TYPE CADWELD
~
~
MONOPOLE
ANTENNA FRAME GROUNDING DETAILSCALE: NTS3
EG-2
GROUNDING DETAILS
3. BAR IS TINNED 0.0003" TYP. (0.0002" MIN) THICK.
1"
1/2"
2. BAR STOCK IS 1/4" THICK SOLID COPPER.
1. ALL HOLES ARE COUNTERSUNK 1/16".
1 1/8"
NOTE:
4"
1" 4" 1" 1"
1"
0.4" DIA(50 TYP)
24"
LOWER BAR
1" 1" 1" 1" 1"1"1" 1" 1"
6 1/2"
0.815"
1"1" 4" 1"
9/16" DIA(8 TYP)
1 1/8"
11/16" DIA(2 TYP)
7/8"UPPER TOWER BUSS 7/8"
(2 TYP)11/16" DIA
1 1/8"
(8 TYP)9/16" DIA
1"
1/2"1 1/8"
4"
1" 2"2" 1"
1"
24"
(50 TYP)0.4" DIA
1"1"1" 1"1" 1"1" 1" 1"1"
0.815"
6 1/2"
2"1" 1" 2" 1"
POWER DISTRIBUTION PANEL GROUNDINGSCALE: NTS
3. CONTRACTOR SHALL ENSURE ENCLOSER IS RODENT-PROOF
COMPARTMENT ACCESS COVER SCREWS LOST DURING2. CONTRACTOR SHALL REPLACE MISSING
AFTER INSTALLATION OF CABINET & CONDUITS.
INSTALLATION.
6
PERMANENT ENGRAVED PLASTIC LABELS NOTING1. CONTRACTOR SHALL LABEL CIRCUIT BREAKERS W/
TO GROUND BUSS AT BTS EQUIPMENT
POWER DISTRIBUTION CENTER NOTES
FUNCTION OF BREAKER.
GROUNDING STRIPSUPPLIED
NEUTRAL GROUND
NEUTRAL TERMINAL
OCCURS AT DISCONNECT
POWER
COPPER WIRETO GROUND RING (TYP.)
#2 SOLID TINNED
GROUNDED (NEUTRAL) ENTRANCE CONDUCTOR
SERVICE ENTRANCE GROUNDINGSCALE: NTS7
SERVICE ENTRANCE RACEWAY (TOP OR BOTTOM FEED)
SHALL BE A NEMA 3R ENCLOSURE
IF BOLTED HUB OR SELF BONDING HUB IS USED BOND JUMPER IS NOT REQUIRED (TYP.)
METER SOCKET AND MAIN DISCONNECT ENCLOSURE
NEUTRAL LAY IN LUG SHALL BE INSULATED FROM ENCLOSURE
MAIN SERVICE DISCONNECT
NEUTRAL BUS
GROUND BUS
TO ELECTRICAL ISOLATED GROUND ROD
BOND NEUTRAL AND GROUND BUS AT SERVICE DISCONNECT
#6 LEADS TO COAX GROUND KITS
#6 LEADS TO COAX GROUND KITS
CONNECT TO TOWER
#2/O BUSS INTERCONNECT
LIGHTNING ROD IF REQUIRED
#2 AWG GREEN INSULATED, STRANDED GROUND WIRE CONTINUOUS FROM UPPER TOWER GROUND BAR. CONNECT TO LOWER TOWER GROUND BAR.
UPPER GROUND BAR (4"x12" TINNED C.U.)
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
ONTAE I
expires 11-30-2006
F0 LLI
Y8109
E
A
ICL
PAC
TS
HT DAD
ESNE
D
CE
ANI K
SI
A.US
TTIHR C
8" DIA. x 42" PVC WITH FEMALE ADAPTER & SCREW ON CAP #MT-C6492
1" WIDE SLOT. TYPICAL FOR 2. EXTEND 2" ABOVE GROUNDRING (8" TYPICAL)
#2 SOLID, BARE, TINNED COPPER GROUNDING CONDUCTOR
EXOTHERMIC WELD(THERMOWELD OREQUIVALENT) DIRECTLY TO TOP OF GROUND ROD
5/8" x 10' COPPER CLADSTEEL GROUND ROD
42" MAX.
#2 SOLID, BARE, TINNED COPPER GROUND RING
MALE SCREW COVER. INSTALLWITH TEFLON LUBRICANT
SUBGRADE
FINISHED GRADE
PVC COLLAR
2"MAX.
EXOTHERMIC WELD(THERMOWELD OR EQUIVALENT). PARALLEL,NO T-WELDS ALLOWED.
EXTERIOR GROUND RING#2 SOLID, BARE, TINNEDCOPPER GROUNDINGCONDUCTOR
JUMPER, #2 SOLID, BARE, TINNED COPPER GROUNDING CONDUCTOR
NO SLAG OR DEFORMITIES ALLOWED
FENCE POST
#2 STRANDED CU. WELDINGCABLE BY MTS #MT-C5915
STAINLESS STEELSELF-TAPPING SCREWS
EXOTHERMIC WELD(THERMOWELD OREQUIVALENT)
FINISHED GRADE
SUBGRADE
#2 SOLID, BARE, TINNED COPPER WIRE. CONNECTTO GROUND ROD OR RINGPER GROUNDING PLAN
#2 SOLID, BARE,TINNED COPPER WIREEXTEND TO OPPOSITEFENCE POST FORBURIED GATE JUMPER
GATE
45 DEG
REES M
IN. BEN
DING
RADIUS (
TYPIC
AL)
#2 SOLID, BARE,TINNED COPPERGROUND RING
5/8" X 10' COPPER CLADSTEEL GROUND ROD
FINISHED GRADE
42" MIN.
15° MAX
SUBGRADE
EG-3
GROUNDING DETAILS
DETAIL OF GATE GROUNDING SCALE: NTS1
5 TIE CONNECTIONSCALE: NTS
GROUND ROD DETAILSCALE: NTS6
TEST WELL DETAILSCALE: NTS2
LIGHTNING ROD DETAILSCALE: NTS
Flat Surface Base
Lightning conductor
Air Terminal - Harger or T-Mobile Approved Equivalent
3
Cable fastener
LIGHTNING ROD CONNECTIONSCALE: NTS4
GROUND BAR DETAILSCALE: NTS7
CAD WELD
GROUND BARON MONOPOLE
#2 AWG FROM DESIGNATEDSECTOR GROUND BAR@ TOP OF MONOPOLE
#6 AWG FROMANTENNA CABLEGROUND KIT
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
ONTAE I
expires 11-30-2006
F0 LLI
Y8109
E
A
ICL
PAC
TS
HT DAD
ESNE
D
CE
ANI K
SI
A.US
TTIHR C
LEGEND
1"
2"
ICE BRIDGE SUPPORT POST
VS CADWELD #2 GND WIRE6" ABOVE GRADE FROM POSTTO GND RING
VS CADWELD #2 GND WIREFROM ICEBRIDGE TO POST
ICEBRIDGE
VS CADWELD #2 GND WIRE FROM FENCE POSTTO HORIZONTAL RAILS
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
CONNECT #2 GND WIRE FROMFENCE POST TO TOP RAILWITH APPROVED T-MOBILECONNECTION
CONNECT #2 GND WIRE ATALL HORIZONTAL RAIL SPLICESWITH APPROVED T-MOBILE CONNECTION
GRADE
6"12
"
RING GROUND#2 AWG BCW
CABLE TO RODCONNECTORBURNDY TYPE GAR
CLEAN SAND FILL
#2 AWG BCWPIGTAIL
3'-6
" MIN
.
24"
GROUND ROD COPPERWELD5/8" DIA. X 10'-0" LONG
OR
6" B
ELO
W F
RO
STLI
NE
10" DIA., 42" LONGHARGER CAT. NO. 360P-42
LOOP AS LARGE ASPOSSIBLE TO AVOIDSHARP BEND
STEEL GROUNDWELL COVERHARGER CAT. NO. 10PS
OPTIONAL BARBED WIRE ABOVE CHAIN LINK FENCE (CONFIRM w/SITE PLAN)
1- GROUND BUSS BAR, 1/4"X 4"X 24", CONFIRM w/T-MOBILE PROJECT MANAGER THE APPROVED BUSS MFR. HOLE CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION 2- INSULATORS, CONFIRM THE APPROVED BUSS MFR. w/T-MOBILE 3- 5/8" LOCKWASHERS, CONFIRM w/T-MOBILE THE APPROVED BUSS MFR. (NEWTON INSTRUMENT CO. CAT. NO. 3015-8 OR EQUIVALENT) 4- WALL MOUNTING BRACKET, NEWTON INSTRUMENT CO. CAT NO. A-6056 OR APPROVED EQUIVALENT (CONFIRM w/T-MOBILE THE APPROVED BUSS MFR.) 5- 5/8-11 X 1" H.H.C.S. BOLTS, NEWTON INSTRUMENT CO. CAT NO. 3012-1 OR APPROVED EQUIVALENT (CONFIRM w/T-MOBILE THE APPROVED BUSS MFR.)
ALTERNATE EQUALS-COMSCOPE, 1/4"X 4"X 14" BUS BAR W/INSULATED HARDWARE-#GB0414IT (CONFIRM w/T-MOBILE THE APPROVED BUSS MFR.)
GROUNDING OF UTILITY RACKSCALE: NTS
ELECTRICAL SERVICE
TELCO SERVICE-ONE SPARE
3
GROUND ALL ABOVEGRADE RGS CONDUIT@ ELECTRIC POST& PPC-MINI CABINET
PPC-MINI CABINETS
ELECTRIC METER
#2 SOLID TINNED COPPER GROUNDWIRE FROM UTILITY CONDUITS TOGROUND RING
GROUND RING
M
RING WITH EXOTHERMIC CONNECTION
ALL ABOVE GRADE RGS CONDUITTO BE GROUNDED TO GROUND
NOTES:1.)
STANDARD GROUND INSPECTION WELLSCALE: NTS2GROUNDING - STANDARD GROUND BAR DETAIL
SCALE: NTS1
STANDARD LUG CONNECTION OF GROUND LEADS TO GROUND BAR DETAILSCALE: NTS6
FENCE POSTS & RAILSSCALE: NTS5ICEBRIDGE & POSTS
SCALE: NTS4
2. FOR GROUND BOND TO STEEL ONLY: INSERT A DRAGON
WIRE (GROUNDED TO GROUND BAR)(STANDARD ANDREW GROUNDING KIT)
AND ALWAYS DIRECT GROUND WIRE DOWNNOTE: DO NOT INSTALL CABLE GROUND KIT AT A BEND
TO GROUND BAR.
CABLE GROUND KITWEATHERPROOFING KIT
2 1/2" DIA.
ANTENNA CABLE
MAX.
ANDREW #221213
ALL SURFACES WITH KOPR-SHEILD.TOOTH WASHER BETWEEN LUG AND STEEL. COAT
#6 AWG STRANDED COPPER GROUND
S/S FLAT WASHER
S/S BELLEVILLE WASHER
S/S NUT
BELLEVILLES. COAT ALL SURFACES WITH KOPR-1. ALL HARDWARE 18-8 STAINLESS STEEL INCLUDING
SHEILD BEFORE MATING.
NOTES:
S/S BOLT (1 OF 2)
S/S FLAT WASHER
COPPER BUSS
STANDARD CONNECTION OF CABLE GROUND KIT TO ANTENNA CABLE SCALE: NTS7
GROUNDING DETAILS
EG-4
ALGONQUINCH46-433
CONST.
RF
OPS
PROPERTY
CH46-433
T- MOBILE APPROVALS
LANDLORD APPROVAL
DATE
SIGNATURE
DRAWN BY:
PROJECT NO:
R.A.HGMS, TPAPPROVED BY:
SUITE 1008550 WEST BRYN MAWR AVE.T-MOBILE
CHICAGO, IL 60631MAIN: (773) 444-5400?
ARBOR LN. & ALAN DR.
T Mobile
2015. S. ARLINGTON HEIGHTS SUITE 111ARLINGTON HEIGHTS,IL 60005MAIN: (847) 981-0801
ONCORDIA WIRELESS, INC.C
CHECKED BY: R.H.CHECKED BY: GMS
ALGONQUIN IL
PUBLIC WORKS
ONTAE I
expires 11-30-2006
F0 LLI
Y8109
E
A
ICL
PAC
TS
HT DAD
ESNE
D
CE
ANI K
SI
A.US
TTIHR C