solar-mount-residential photovoltaic pool pump … · situs: 1211 ne 28 avenue, pompano beach, fl...

Post on 22-Sep-2020

2 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

PUMP

PUMP PLUSOPTIONALHEATING ORACCESSORYEQUIPMENT

RETURN TO POOLFR

OM

PO

OL

LORENTZP S600BADU PUMP

MOUNT DETAILS SHOWNON THIS PLAN. INSTALLPER OEM INSTRUCTIONS

PV CONTROLLERLIGHTNINGARRESTOROPTIONAL

+

+ + +

3 MODULS IN 1 ARRAY

PV MODULE PV MODULE PV MODULE

J BOX

ATTACH TO ROOF FRAMINGMEMBER WITH 2 LAG BOLTSEACH STANDOFF

4'-0" 4'-0"

3'-0"

PZ2

PZ2

PZ3

PZ1

DN

4/1

°

SOUTH EAVE

HIP

RIDGE

1 STORY RESIDENCE 3 PV MODULES 4/12 TILE ROOF

SHEET NO:

PUBLISHED:

SHEET NAME:

DRAWN: CHECKED:SB AG

EN

LAR

GE

D V

IEW

ING

& H

YP

ER

LIN

KS

:P

RIN

T V

ER

SIO

N O

F T

HIS

PLA

N P

RO

VID

ES

MIN

IMU

M I

NF

OR

MA

TIO

N N

EE

DE

D B

Y U

SE

RS

.

ELE

CT

RO

NIC

VE

RS

ION

(E

V)

PR

OV

IDE

S M

AG

NIF

IED

VIE

WIN

G U

P T

O 6

40

0%

. E

V A

LSO

PR

OV

IDE

S H

YP

ER

LIN

KA

CC

ES

S T

O O

EM

MA

NU

ALS

AN

D A

BU

ND

AN

T O

TH

ER

SU

PP

LEM

EN

TA

RY

IN

FO

RM

AT

ION

.EV

MA

Y B

E

AC

CE

SS

ED

AT

: W

WW

.GE

ZE

LMA

NP

E.C

OM

/PV

/0

31

8P

.BS

_K

ien

Po

olP

um

p_

Po

mp

an

o_

FL.

dw

g

REVISIONS:

03SCALE: NTS

SAMPLE INSTALLATION PHOTOS

I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES ANDEQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT.ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2008 NATIONAL ELECTRICAL CODE. CERTAIN DETAILS OF THIS PROJECTMAY DIFFER, REFER TO OEM LITERATURE WHICH SHALL PREVAIL.

CONTRACTOR RESPONSIBLE TO VERIFY THE FIT OF THIS ARRAY PRIOR TO INSTALLATION: THE SOLAR MODULE ARRAY SHOWNHERE IS BASED ON THE FIELD DATA PROVIDED BY THE CONTRACTOR. CONTRACTOR SHALL CONTACT THE ENGINEER IF THEARRAY MAY NOT FIT AS PROJECTED. SATELLITE IMAGERY SHOWN MAY NOT CORRECTLY INDICATE POTENTIAL CURRENT SHADINGOF PROPERTY. CONTRACTOR RESPONSIBLE TO VERIFY SUN EXPOSURE AND SHADING OF INSTALLATION PRIOR TO INSTALLATION!

C

OP

Y R

IGH

T &

IN

TE

LLE

CT

UA

L P

RO

PE

RT

Y N

OT

ICE

•T

HIS

PLA

N S

ET

IS

CO

PY

RIG

HT

PR

OT

EC

TE

D A

ND

CO

NT

AIN

S I

NT

ELL

EC

TU

AL

PR

OP

ER

TY

WH

ICH

BE

LON

GS

TO

ALL

EN

GE

ZE

LMA

N P

E.

•A

CC

ES

S I

S G

IVE

N T

O T

HE

IN

FO

RM

AT

ION

HE

RE

ON

SO

LELY

FO

R T

HE

PU

RP

OS

E O

F C

OM

PLE

TIO

N O

F T

HE

PR

OJE

CT

FO

R W

HIC

H I

T I

S I

NT

EN

DE

D.

•N

O O

TH

ER

US

E M

AY

BE

MA

DE

OF

TH

E I

NF

OR

MA

TIO

N,

DR

AW

ING

S,

OR

ID

EA

S H

ER

EO

N W

ITH

OU

T T

HE

EX

PR

ES

S,

WR

ITT

EN,

PE

RM

ISS

ION

OF

ALL

EN

GE

ZE

LMA

N P

E

ALL AFFIDAVITS, DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDC

C-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC C-700 ORPROVISIONS THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT, DESIGN, OPINION, CALCULATION OR OTHER ENGINEERING SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC

C-700 MAY BE VIEWED AT: HTTP://GEZELMANPE.COM/REFERENCE/AG/C-700.PDF

THIS PLAN IS ONLINE FOR REVIEW @

WWW.GEZELMANPE.COM/PV/0318P.BS_KIENPOOLPUMP_POMPANO_FL.PDF

CO

NT

AC

T D

ES

IGN

TE

AM

@

ww

w.G

eze

lma

nP

E.c

om

ALLEN GEZELMAN16502 HANNA RD.LUTZ, FLORIDA 33549

PH. 813 650 7246FX. 866 397 9050Allen@Gezelman PE.COM

www.GezelmanPE.com

I CERTIFY THAT THIS DESIGN &SPECIFICATIONS MEET THE CURRENTFLORIDA BUILDING CODE

INS

TA

LLA

TIO

N O

F A

RO

OF

MO

UN

T

PH

OT

OV

OLT

AIC

PO

OL

PU

MP

SY

ST

EM

TH

E

KIE

N

RE

SID

EN

CE

VULT 170_MPH, VASD 131.7 MPH

EXPOSURE: C, RISK CATEGORY: II, PZ2 WIDTH 3-FT

WORSE CASE WIND FORCES; UPLIFT, NEGATIVE, PSF, PZ1-32, PZ2-54.5, PZ3-83.4_PSFCO

DE

VE

RIF

Y

MODULE# SHARP ND 240 QCJ, FSEC: #SH11-NT90-0616

DESIGNED PER: ASCE 7-10, FBC 2010

WIN

D

01SCALE: 1/4" = 1'-0"

ROOF LAYOUT PLAN

AHJ: BROWARD COUNTY, PARCEL ID# 4843 30 21 0940

SIT

US

: 1

21

1 N

E 2

8 A

VE

NU

E,

PO

MP

AN

O B

EA

CH

, F

L

STRUCTURAL LOAD FROM EQUIP < 4PSF

10.21.2013

OWNER OF RECORD:

1211 NE 28 AVE POMPANO BEACH FL 33062-3822

KIEN,F MICHAEL

PV POOL PUMP STRUCTURAL INSTALLATION NOTES -ELECTRICAL DESIGN BY CONTRACTOR.

INSTALLATION SHALL BE MADE USING UNIRAC STANDARD RAILS INSTALLED PER OEM

INSTRUCTIONS HTTP://WWW.UNIRAC.COM/PDF/II227.PDF AND DRAWING FIGURES THIS PLANSHEET.

RAILS SHALL BE CONNECTED WITH L-FEET ON TOP OF STAND-OFFS SOLIDLY ATTACHED INTO

ROOF FRAMING ON 4-FT CENTERS USING MINIMUM 5/16-INCH DIAMETER CRS (CORROSIONRESISTANT STEEL) LAGS OF SUFFICIENT LENGTH TO ACHIEVE MINIMUM OF 3-INCH EMBEDMENT.A GENEROUS PUDDLE OF FLORIDA PCA ROOF SEALANT BETWEEN STANDOFF AND ROOFCOVERING IS ADEQUATE WATERPROOFING. CONTRACTOR IS FREE TO CHOOSE ALTERNATEMETHOD ACCEPTABLE TO AHJ (AUTHORITY HAVING JURISDICTION AKA BUILDING DEPARTMENT).

EACH PV MODULE SHALL BE SUPPORTED BY TWO RAILS AND SHALL ATTACH THERETO ATCROSSING POINTS (4-PER MODULE). ADJACENT MODULES MAY SHARE ATTACHMENTS TO RAIL.

04SCALE: NTS

PV MODULE DATA SHEET09

SCALE: NTS

FLAT OR BARREL TILE ATTACHMENT - MOUNTING SYSTEM- UNIRAC.COM

10SCALE: NTS , THESE PICTURES ARE TYPICALL INSTALLATIONS

SAMPLE INSTALLATION PHOTOS

DETAILS MAY VARY - CURRENT OEM INSTRUCTIONS PREVAILHTTP://WWW.UNIRAC.COM/RESIDENTIAL/RESIDENTIAL-PRODUCTS/SOLAR-MOUNT-RESIDENTIAL

UNIRAC CODE COMPLIANT LETTER - FLORIDA:

THIS PV POOL PUMP PLAN WILL PROVIDE ADEQUATE PUMPING CAPACITY TO

SATISFY THE REQUIREMENTS OF A SOLAR POOL HEATER FOR A TYPICAL RESIDENTIAL

POOL IN CONJUNCTION WITH MY PLANS http://www.cadvice.us/sw/AS.2.2.PH.pdf

& http://www.cadvice.us/sw/AS.2.2.PH_FSM.pdf

BIG POOLS, POOLS WITH SPECIAL CLEANING APPARATUS, POOLS WITH HIGH

BACK-PRESSURE FILTRATION, AND/OR NON-STANDARD HYDRAULICS WILL REQUIRE

SITE-SPECIFIC ENGINEERING. CONTRACTOR & OTHERS ARE DIRECTED TO OEM

PERFORMANCE DATA http://www.lorentz.de/pdf/lorentz_ps600_badutop_en.pdf

APPLICABLE PV MODULE & PUMP PERFORMANCE SHOULD BE CAREFULLY

CONSIDERED IN CONJUCTION WITH THE POOL PUMPING REQUIREMENTS AND

OTHER IMPORTANT SITE CHARACTERISTICS.

02SCALE: NTS

PARCEL (PROPERTY APPRAISER DATA)

SYSTEM:

UNIRAC, INC.

1411 BROADWAY BOULEVARD NE

ALBUQUERQUE NM 87102-1545

TELEPHONE: 505-242-6411

INSTALLATION LOCATION

11SCALE: NTS

ASCE 7 PRESSURE ZONE DIAGRAM

04SCALE: NTS

PV POWERED PUMP DATA SHEET04

SCALE: NTS

SYSTEM INSTALLATION DIAGRAM

Siggi
Snapshot
Siggi
Snapshot
Siggi
Image
Siggi
Image
Siggi
Snapshot
Siggi
Snapshot
Siggi
Snapshot
Siggi
Snapshot
Siggi
Snapshot

top related