preliminary data sheet -8254-11 front-end module for …...sky5®-8254-11 front-end module for lte...
Post on 24-Mar-2020
42 Views
Preview:
TRANSCRIPT
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 205315C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 31, 2019 1
PRELIMINARY DATA SHEET
SKY5®-8254-11 Front-End Module for LTE and NR Applications Multi-band 4G / 5G handsets - Band 41 and n41
Features Fully Baseband Agnostic Design
Full Power APT support without DPD
HB S-PAD covering Band n41
MIPI® v2.1 compliant 52 MHz RFFE bus
High performance ET/APT PA core
50 ohm input/output impedance with internal DC-blocking
Continuous bias control via RFFE interface
Low leakage current in power-down mode
Features Integrated Tx-Rx switches
Small, low profile package - 3.0 mm x 5.0 mm x 0.7 mm (Max.) - 30-pad surface mount (SMT) configuration
Description SKY58254-11 is a recent addition to our Sky5 portfolio of 5G Technology products. Packaged in a single 3.0 mm x 5.0 mm x 0.7 mm (Max.) form factor, this versatile and fully matched Front-End Module (FEM) supports band 41 5G and NR applications. The 30-pad surface mount (SMT) module consists of PA blocks, input/output impedance matched to 50 ohms, an MIPI standard digital control block, single-ended filters, Tx-Rx switches and forward/reverse coupler.
Utilizing an enhanced architecture, SKY58254-11 covers full Band 41 and meets the spectral linearity requirements of CP-OFDM and DFTS-OFDM modulations with up to 100 MHz bandwidth and up to 273 resource block allocations. Output power is controlled by varying input power and adjusting VCC maximizes efficiency. Extremely low leakage current maximizes handset stand-by time
.
PRELIMINARY DATA SHEET SKY5®-8254-11 FRONT-END MODULE for LTE and NR
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 2 October 31, 2019 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 205315C
Figure 1. SKY58254-11 Functional Block Diagram
SKY5®-8254-11 FRONT-END MODULE for LTE and NR PRELIMINARY DATA SHEET
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 205315C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 31, 2019 3
Table 1. SKY58254-11 Supported Bands and Modes
Band Modes Supported LTE Bandwidths (MHz) ET / APT
n41 TDD NR 5, 10, 15, 20, 25, 30, 40, 50, 60, 80, 100 ET /APT
B41 TDD LTE 5, 10, 5, 20 ET /APT
Table 2. SKY58254-11 Absolute Maximum Operating Conditions (Exposure to maximum rating conditions for extended periods may reduce device reliability. No damage to device when only one parameter set at the maximum rating with all other parameters set at or below their nominal value.)
Parameter Symbol Condition Min Typ Max Unit
RF input power PIN 152 dBm
Supply Voltage4 VBATT No RF –0.5 6.0 V
RF –0.5 6.03
VCC1, VCC2 6.0
Digital Control Lines CLK, DATA, VIO –0.5 2.2 V
Case Temperatures TCASE Operating –30 +110 °C
TSTG Storage –30 +150
Electrostatic Discharge Sensitivity IEC IEC 61000-4-24 V
ESD_HBM Human Body Model RF Pad (Class 1C) –1000 1000
Human Body Model RF Pads (Class 1B) –500 1000
Human Body Model Other (Class 1A) –250 1000
ESD_CDM Charged Device Model (Class C2) –500 500
Leakage Current Power-down Mode, VBATT = 4.8 V 0 11 μA
1 Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value.
2 50 ohm load applied / center channel. 3 Avoid static DC voltages greater than 5.5 V for extended periods of time. 4 Applies to antenna ports only.
Table 3. SKY58254-11 Recommended Operating Conditions
Parameter Condition Min. Typ. Max. Unit
Supply Voltage VBATT 3.0 5.0 V
VCC1, VCC2 0.5 5.0
Digital Control Signals Low 0 0.5 V
High 1.35 1.8 2.0
Current 50 μA
On/Off Time DC: ICC to within 90% of final value 10 μs
RF: POUT within 1dB of final value 1
Ambient Temperature 3GPP –20 +25 +85 °C
Table 4. SKY58254-11 Electrical Specifications – 4G / 5G PRATED (Recommended Maximum Operating Power - MPR0)
Band Modulation (MPR = 0 dB) Power Mode PRATED at Module Antenna Pad Unit
41 NR/LTE APT, HPM, PC2, 5.0V 29.5 dBm
APT, HPM, PC3, 3.8V 26.5
PRELIMINARY DATA SHEET SKY5®-8254-11 FRONT-END MODULE for LTE and NR
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 4 October 31, 2019 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 205315C
Table 5. SKY58254-11 – Band n41 Tx Performance at Module Antenna Pad Unless otherwise specified: Environmental Conditions = NTC, PC2 = POUT_MAX, Average Power Tracking (APT) mode, MPR = 0, 50 ohm termination, NR modulation = Test waveform 1, see Table 9. For NTC and ETC conditions, see Table 4.
Parameter Symbol Conditions Min Typ Max Unit
Operating Frequency ƒ — 2496 2690 MHz
Maximum NR Output Power POUT_MAX_NR_NTC 4GHB_VCC = 5.0 V, NTC 29.5 dBm
Gain G_NTC NTC 26.75 28.5 30.25 dB
EVM, NR EVM_NR_NTC Test waveform 3 1.5 % rms
EVM_NR_ETC Test waveform 3, ETC
NR ACLR ACLR_NR_NTC Test waveform 2 –38 –35 dBc
ACLR_NR_ETC Test waveform 2, ETC –33
NR UTRA1 UTRA1_NR_NTC Test waveform 2 –43 –37 dBc
UTRA1_NR_ETC Test waveform 2, ETC –35
NR UTRA2 UTRA2_NR_NTC Test waveform 2 –49 –41 dBc
UTRA2_NR_ETC Test waveform 2, ETC –39
ICC Power Current ICC Test Waveform 1 mA
Test waveform 2
IBATT Power Current IBATT Test Waveform 1 mA
Test waveform 2
Harmonic 2ƒo P2ƒo LTE 1RB, MBW = 1 MHz –40 dBm
3ƒo P3ƒo –40
4ƒo and higher Pnƒo –40
Band Noise Nb GPS and GLONASS Band Noise –168 dBm/Hz
LB Rx band noise at 600–960 MHz –171
MB Rx band noise at 1805–1880 MHz –171
2.4 GHz WiFi, 2474–2495 MHz, LTE 1RB, measured at Ant port –156
Input Impedance and VSWR VSWR_IN 1.3:1 2:1
Stability, spurious emissions S POUT PRATED, Antenna port VSWR = 10:1, ETC –36 dBm
Ruggedness Ru POUT PRATED, Antenna port VSWR = 10:1, ETC No Permanent Damage/ Change in Performance
SKY5®-8254-11 FRONT-END MODULE for LTE and NR PRELIMINARY DATA SHEET
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 205315C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 31, 2019 5
Table 6. SKY58254-11 – Band n41 Tx Performance at Module Antenna Pad Unless otherwise specified: Environmental Conditions = NTC, PC3 = POUT_MAX, Average Power Tracking (APT) mode, MPR = 0, 50 ohm termination, NR modulation = Test waveform 1, see Table 9. For NTC and ETC conditions, see Table 4.
Parameter Symbol Conditions Min Typ Max Unit
Operating Frequency ƒ — 2496 2690 MHz
Maximum NR Output Power POUT_MAX_NR_NTC 4GHB_VCC = 5.0 V, NTC 26.5 dBm
Gain G_NTC NTC 26.75 28.0 30.25 dB
EVM, NR EVM_NR_NTC Test waveform 3 1.5 % rms
EVM_NR_ETC Test waveform 3, ETC
NR ACLR ACLR_NR_NTC Test waveform 2 –38 –35 dBc
ACLR_NR_ETC Test waveform 2, ETC –33
NR UTRA1 UTRA1_NR_NTC Test waveform 2 –43 –37 dBc
UTRA1_NR_ETC Test waveform 2, ETC –35
NR UTRA2 UTRA2_NR_NTC Test waveform 2 –49 –41 dBc
UTRA2_NR_ETC Test waveform 2, ETC –39
ICC Power Current ICC Test Waveform 1 mA
Test waveform 2
IBATT Power Current IBATT Test Waveform 1 mA
Test waveform 2
Harmonic 2ƒo P2ƒo LTE 1RB, MBW = 1 MHz –50 dBm
3ƒo P3ƒo –40
4ƒo and higher Pnƒo –40
Band Noise Nb GPS and GLONASS Band Noise –168 dBm/Hz
LB Rx band noise at 600–960 MHz –171
MB Rx band noise at 1805–1880 MHz –171
2.4 GHz WiFi, 2474–2495 MHz, LTE 1RB, measured at Ant port –156
Input Impedance and VSWR VSWR_IN 1.3:1 2:1
Stability, spurious emissions S POUT PRATED, Antenna port VSWR = 10:1, ETC –36 dBm
Ruggedness Ru POUT PRATED, Antenna port VSWR = 10:1, ETC No Permanent Damage/ Change in Performance
PRELIMINARY DATA SHEET SKY5®-8254-11 FRONT-END MODULE for LTE and NR
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 6 October 31, 2019 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 205315C
Table 7. SKY58254-11 – Band 41 Rx Performance Unless otherwise specified: Environmental Conditions = NTC, POUT = POUT_MAX, MPR = 0, 50 ohm termination, NR modulation = Test waveform1. For NTC and ETC conditions, see Table 4.
Parameter Symbol Conditions Min Typ Max Unit
Frequency Range ƒ — 2496 2690 MHz
Insertion Loss RxIL_NTC Rx Band (2496–2690 MHz), Rx port mismatch removed per optimized LNA matching
3.4 dB
Rx Port VSWR VSWR_Rx_ETC Rx Band (2496–2690 MHz), ETC 1.5:1 2.0:1
ANT Port VSWR VSWR_ANT_ETC Rx Band (2496–2690 MHz), ETC 2.0:1
Absolute Attenuation Antenna to Rx pad
Attenuation at LB Tx, 699–862 MHz 43 48 dB
Attenuation at B3 Tx, 1710–1785 MHz 43 40
Attenuation at ISM 2.4 G, 2400–2442 MHz 35 40
Attenuation ISM 5G MHz–1980 MHz 36
Table 8. SKY58254-11 – Coupler Performance Unless otherwise specified: Environmental Conditions = NTC, PC2 = POUT_MAX, MPR = 0, 50 ohm termination, NR modulation = Test waveform1. LTE modulation = QPSK, 10MHz/12RB. For NTC and ETC conditions, see Table 4.
Parameter Symbol Conditions Minimum Typical Maximum Units
Frequency Range ƒ NTC 2496 2690 MHz
Coupler Switch Insertion Loss CPL_LOSS Bypass operation 1.3 2.3 dB
Coupling Factor CPL_FACTOR 20 25 dB
Power Variation into Mismatch CPL_PWR_RIPPLE NTC, VSWR 2.5:1 dB
Coupler Isolation ISO dBm
Table 9. SKY58254-11 NR Test Waveform
Test Waveform Channel Bandwidth (MHz) SCS (kHz) Modulation RB Allocation MPR (dB)
Test waveform 1 100 30 DFT-S-OFDM QPSK 135 @ 67 0
Test waveform 2 100 30 CP-OFDM QPSK 273 @ 0 3
Test waveform 3 100 30 CP-OFDM 256QAM 273 @ 0 6.5
SKY5®-8254-11 FRONT-END MODULE for LTE and NR PRELIMINARY DATA SHEET
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 205315C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 31, 2019 7
Table 10-1. SKY58254-11 Tx Register Map
Regi
ster
Add
ress
(Hex
)
Register Name Data
Bits
Bit Name Defa
ult
Description Stat
e Va
lue
State Broa
dcas
t Sla
ve ID
and
Gr
oup
Slav
e ID
Sup
port
Trig
ger S
uppo
rt
Activ
e Tr
igge
r
Mas
ked
Writ
e Su
ppor
t
RW
Register Class: PA Control Block 0x00 PA_CTRL_0 7 APT_CAP_SWITCH_
METHOD 0 APT_CAP_SWITCH_METHOD 0x00 APT cap controlled by Reg0<1:0> if Reg5<7>=0 No
Stan
dard
TRIG
GER0
Y RW
0x01 APT cap controlled by Reg5<1>
6 Bias mode sel 0 Bias mode sel 0x00 Biasmode1
0x01 Biasmode2
5 PAE_boost 0 PC2_PC3_PABoost 0x00 PC2_PAEboost
0x01 PC3_PAEboost
4:3 BAND_SEL 00 Selects PA band 0x00 Off
0x01 B41_TX
0x02 RESERVED
0x03 RESERVED
2 PA_EN 0 Enable PA 0x00 Off
0x01 On
1:0 GAIN_MODE[1:0] 00 Selects PA gain mode 0x00 APT_HPM-A: APT cap switch On when BS Enable AND Reg0 in control APT cap switch
0x01 APT_LPM-B: APT cap switch On when BS Enable AND Reg0 in control APT cap switch
0x02 ET_HPM: APT cap switch OFF when Reg0 in control APT cap switch
0x03 APT_HPM-B: APT cap switch On when BS Enable AND Reg0 in control APT cap switch
0x01 PA_CTRL_1 7:4 IREF2[4:1] 0000 Sets IREF2 current (mapped to 8 bits using Regx4[5] and fuses)
0x00 250 μA No
Stan
dard
TRIG
GER0
Y RW
0x01 500 μA
0x02 750 μA
0x03 1000 μA
0x04 1250 μA
PRELIMINARY DATA SHEET SKY5®-8254-11 FRONT-END MODULE for LTE and NR
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 8 September 13, 2019 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 205315C
Table 10-2. SKY58254-11 Tx Register Map
Regi
ster
Add
ress
(Hex
)
Register Name Data
Bits
Bit Name Defa
ult
Description Stat
e Va
lue
State Broa
dcas
t Sla
ve ID
and
Gr
oup
Slav
e ID
Sup
port
Trig
ger S
uppo
rt
Activ
e Tr
igge
r
Mas
ked
Writ
e Su
ppor
t
RW
0x01 PA_CTRL_1 7:4 IREF2[4:1] 0000 Sets IREF2 current (mapped to 8 bits using Regx4[5] and fuses)
0x05 1500 μA No
Stan
dard
TRIG
GER0
Y RW
0x06 1750 μA
0x07 2000 μA
0x08 2250 μA
0x09 2500 μA
0x0A 2750 μA
0x0B 3000 μA
0x0C 3250 μA
0x0D 3500 μA
0x0E 3750 μA
0x0F 4000 μA
3:0 IREF1[4:1] 0000 Sets IREF1 current (mapped to 8 bits using Regx4[4] and fuses)
0x00 200 μA RW
0x01 350 μA
0x02 500 μA
0x03 650 μA
0x04 800 μA
0x05 950 μA
0x06 1100 μA
0x07 1250 μA
0x08 1400 μA
0x09 1550 μA
0x0A 1700 μA
0x0B 1850 μA
0x0C 2000 μA
0x0D 2150 μA
SKY5®-8254-11 FRONT-END MODULE for LTE and NR PRELIMINARY DATA SHEET
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 205315C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 31, 2019 9
Table 10-3. SKY58254-11 Tx Register Map
Regi
ster
Add
ress
(Hex
)
Register Name Data
Bits
Bit Name Defa
ult
Description Stat
e Va
lue
State Broa
dcas
t Sla
ve ID
and
Gr
oup
Slav
e ID
Sup
port
Trig
ger S
uppo
rt
Activ
e Tr
igge
r
Mas
ked
Writ
e Su
ppor
t
RW
0x01 PA_CTRL_1 3:0 IREF1[4:1] 0000 Sets IREF1 current (mapped to 8 bits using Regx4[4] and fuses)
0x0E 2300 No
Stan
dard
TRIG
GER0
Y RW
0x0F 2450 μA No Y
Register Class: Switch Control Block 0x02 SW_CTRL 7:2 SPARE 000000 SPARE SPARE SPARE No
Stan
dard
TRIG
GER1
Y RW
1:0 TRX_SW_CTRL[1:0] 00 Selects SW band 0x00 TX (RX_HISO)
0x01 B41_RX
0x02 RESERVED
0x03 HISO
Register Class: ASM Control Block 0x03 CPL_CTRL_0 7:5 SPARE 000 SPARE SPARE SPARE No
Stan
dard
TRIG
GER2
Y RW
4:2 CPL_TERM[1:0] 000 Selects coupler termination (only when CPL control is forward or reverse)
0x00 Termination-A
0x01 Termination-B
0x02 Termination-C
0x03 Termination-D
0x04 Termination-E
0x05 Termination-F
0x06 Termination-G
PRELIMINARY DATA SHEET SKY5®-8254-11 FRONT-END MODULE for LTE and NR
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 10 September 13, 2019 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 205315C
Table 10-4. SKY58254-11 Tx Register Map
Regi
ster
Add
ress
(Hex
)
Register Name Data
Bits
Bit Name Defa
ult
Description Stat
e Va
lue
State Broa
dcas
t Sla
ve ID
and
Gr
oup
Slav
e ID
Sup
port
Trig
ger S
uppo
rt
Activ
e Tr
igge
r
Mas
ked
Writ
e Su
ppor
t
RW
0x03 CPL_CTRL_0 4:2 CPL_TERM[1:0] 000 Selects coupler termination (only when CPL control is forward or reverse)
0x07 Termination-H N
Stan
dard
TRIG
GER2
Y RW
1:0 CPL_CTRL[1:0] 00 Controls CPL termination 0x01 Coupler Forward
0x02 Coupler Reverse
0x03 Coupler in, Coupler out
Register Class: Engineering Control Block 0x04 PA_CTRL_2 7 STD_BIAS 0 Standard bias mode 0x00 Limited bias mode No
Stan
dard
TRIG
GER0
Y RW
0x01 Standard bias mode
6 LoadCAP1_Switch_En
0 Enables loadcap1 switch 0x00 Disable LoadCap1 switch
0x01 Enable LoadCap1 switch
5 OVER CURRENT PROTECTION En
0 controls the Over Current Protection circuit 0x00 Enable OCP
0x01 Disable OCP
4 Varactor Bias sel 0 Varactor Bias sel 0x00 Varactor bias OFF
0x01 Varactor bias ON
3:0 IBOOST[3:0] 0000 Sets IBOOST current 0x00 0 μA (Default)
0x01 100 μA
0x02 200 μA
0x03 300 μA
0x04 400 μA
0x05 500 μA
0x06 600 μA
0x07 700 μA
0x08 800 μA
0x09 900 μA
SKY5®-8254-11 FRONT-END MODULE for LTE and NR PRELIMINARY DATA SHEET
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 205315C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 31, 2019 11
Table 10-5. SKY58254-11 Tx Register Map
Regi
ster
Add
ress
(Hex
)
Register Name Data
Bits
Bit Name Defa
ult
Description Stat
e Va
lue
State Broa
dcas
t Sla
ve ID
and
Gr
oup
Slav
e ID
Sup
port
Trig
ger S
uppo
rt
Activ
e Tr
igge
r
Mas
ked
Writ
e Su
ppor
t
RW
0x04 PA_CTRL_2 3:0 IBOOST[3:0] 0000 Sets IBOOST current 0x0A 1000 μA N
Stan
dard
TRIG
GER0
Y RW
0x0B 1100 μA
0x0C 1200 μA
0x0D 1300 μA
0x0E 1400 μA
0x0F 1500 μA
0x05 APT_SW 7 APT_CAP_SWITCH_METHOD
0 APT_CAP_SWITCH_METHOD 0x00 APT cap controlled by Reg5<0> if Reg0<7>=1 No No NA Y RW
0x01 APT cap controlled by Reg5<0> if Reg0<7>=1
6:1 SPARE 000000 SPARE 0x00 SPARE
0 APT_CAP_SWITCH_CONDITION
0 APT_CAP_SWITCH_CONDITION 0x00 APT CAP Switch OFF
0x01 APT CAP Switch ON
Register Class: User Defined 0x06 Reserved 7:0 Reserved 0000
0000 Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x07 Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x08 Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x09 Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x0A Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x0B Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
PRELIMINARY DATA SHEET SKY5®-8254-11 FRONT-END MODULE for LTE and NR
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 12 September 13, 2019 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 205315C
Table 10-6. SKY58254-11 Tx Register Map
Regi
ster
Add
ress
(Hex
)
Register Name Data
Bits
Bit Name Defa
ult
Description Stat
e Va
lue
State Broa
dcas
t Sla
ve ID
and
Gr
oup
Slav
e ID
Sup
port
Trig
ger S
uppo
rt
Activ
e Tr
igge
r
Mas
ked
Writ
e Su
ppor
t
RW
0x0C Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x0D Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x0E Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x0F Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x10 Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x11 Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x12 Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x13 Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x14 Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x15 Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x16 Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x17 Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x18 Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x19 Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
0x1A Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
SKY5®-8254-11 FRONT-END MODULE for LTE and NR PRELIMINARY DATA SHEET
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 205315C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 31, 2019 13
Table 10-7. SKY58254-11 Tx Register Map
Regi
ster
Add
ress
(Hex
)
Register Name Data
Bits
Bit Name Defa
ult
Description Stat
e Va
lue
State Broa
dcas
t Sla
ve ID
and
Gr
oup
Slav
e ID
Sup
port
Trig
ger S
uppo
rt
Activ
e Tr
igge
r
Mas
ked
Writ
e Su
ppor
t
RW
0x1B Reserved 7:0 Reserved 0000 0000
Reserved for future use. Reads from this register shall cause the READ_UNUSED_REG bit in the RFFE_STATUS register to be set. Writes to this register shall cause the WRITE_UNUSED_REG bit in the RFFE_STATUS register to be set.
N N NA N NA
Register Class: RFFE Reserved 0x1C PM_TRIG 7 PWR_MODE[1],
Operation Mode 1 Defines Normal Operation and Secondary Operation
Modes. When the slave is in Secondary Operation Mode, charge pumps shall be disabled and the slave shall be listening to the RFFE bus.
0 Normal Operation Mode (ACTIVE) Yes N N N RW
1 Secondary Operation Mode (LOW POWER)
6 PWR_MODE[0], State Bit Vector
0 Single bit Powered Reset. Writing a 1 resets all slave registers to their default settings including the Operation Mode bit in PWR_MODE[1]. Always reads back 0.
0 No action (ACTIVE)
1 Powered Reset
5 TRIGGER_MASK_2 0 Trigger Mask 2 0 Data writes to registers tied to TRIGGER_2 is held in shadow registers until the TRIGGER_2 bit is set to 1.
N
1 Data writes to registers tied to TRIGGER_2 go directly to the active registers.
4 TRIGGER_MASK_1 0 Trigger Mask 1 0 Data writes to registers tied to TRIGGER_1 is held in shadow registers until the TRIGGER_1 bit is set to 1.
1 Data writes to registers tied to TRIGGER_1 go directly to the active registers.
3 TRIGGER_MASK_0 0 Trigger Mask 0 0 Data writes to registers tied to TRIGGER_0 is held in shadow registers until the TRIGGER_0 bit is set to 1.
1 Data writes to registers tied to TRIGGER_0 go directly to the active registers.
2 TRIGGER_2 0 Trigger 2. This bit has no effect if TRIGGER_MASK_2 is 1. When the part is in LOW POWER and a trigger request is sent in the same command sequence that still keeps the part in LOW POWER, the trigger request is ignored. This applies to Triggers only, not to Trigger Masks. When the part is in ACTIVE and sent to LOW POWER, or when the part is in LOW POWER and sent to ACTIVE, trigger requests in the same command sequence are NOT ignored.
0 No action. Data is held in shadow registers. Yes
1 Data is transferred from shadow registers to active registers for registers tied to TRIGGER_2.
PRELIMINARY DATA SHEET SKY5®-8254-11 FRONT-END MODULE for LTE and NR
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 14 September 13, 2019 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 205315C
Table 10-8. SKY58254-11 Tx Register Map
Regi
ster
Add
ress
(Hex
)
Register Name Data
Bits
Bit Name Defa
ult
Description Stat
e Va
lue
State Broa
dcas
t Sla
ve ID
and
Gr
oup
Slav
e ID
Sup
port
Trig
ger S
uppo
rt
Activ
e Tr
igge
r
Mas
ked
Writ
e Su
ppor
t
RW
0x1C PM_TRIG 1 TRIGGER_1 0 Trigger 1. This bit has no effect if TRIGGER_MASK_1 is 1. When the part is in LOW POWER and a trigger request is sent in the same command sequence that still keeps the part in LOW POWER, the trigger request is ignored. This applies to Triggers only, not to Trigger Masks. When the part is in ACTIVE and sent to LOW POWER, or when the part is in LOW POWER and sent to ACTIVE, trigger requests in the same command sequence are NOT ignored.
0 No action. Data is held in shadow registers. Yes N N N RW
1 Data is transferred from shadow registers to active registers for registers tied to TRIGGER_1.
0 TRIGGER_0 0 Trigger 0. This bit has no effect if TRIGGER_MASK_0 is 1. When the part is in LOW POWER and a trigger request is sent in the same command sequence that still keeps the part in LOW POWER, the trigger request is ignored. This applies to Triggers only, not to Trigger Masks. When the part is in ACTIVE and sent to LOW POWER, or when the part is in LOW POWER and sent to ACTIVE, trigger requests in the same command sequence are NOT ignored.
0 No action. Data is held in shadow registers.
1 Data is transferred from shadow registers to active registers for registers tied to TRIGGER_0.
0x1D PRODUCT_ID 7:0 PRODUCT_ID [7:0]
0000 0010
This is a read-only register. However, during the programming of the USID a write command sequence is performed on this register, even though the write does not change its value.
0x02 No No No N R
0x1E MANUFACTURER_ID
7:0 MANUFACTURER_ID[7:0]
1010 0101
Manufacturer ID. This is a read-only register. However, during the programming of the USID, a write command sequence is performed on this register, even though the write does not change its value. See http://mid.mipi.org.
0xA5 No No No N R
0x1F MAIN_USID 7:4 MANUFACTURER_ID[11:8]
0001 Manufacturer ID. These bits are read-only. However, during the programming of the USID, a write command sequence is performed on this register even though the write does not change its value. See http://mid.mipi.org.
0x1 No No No N R
USID [3:0]
1100 These bits store the USID of the device. Performing a write to this register using the described programming sequences will re-program the USID. The default value shall not be fused.
0xC RW
SKY5®-8254-11 FRONT-END MODULE for LTE and NR PRELIMINARY DATA SHEET
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 205315C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • October 31, 2019 15
Table 10-9. SKY58254-11 Tx Register Map
Regi
ster
Add
ress
(Hex
)
Register Name Data
Bits
Bit Name Defa
ult
Description Stat
e Va
lue
State Broa
dcas
t Sla
ve ID
and
Gr
oup
Slav
e ID
Sup
port
Trig
ger S
uppo
rt
Activ
e Tr
igge
r
Mas
ked
Writ
e Su
ppor
t
RW
0x20 EXT_PROD UCT_ID
7:0 EXT_PRODUCT_ID [7:0]
0000 0110
Extension to PRODUCT_ID in register 0x1D. This is a read-only register. However, during the programming of the USID a write command sequence is performed on this register, even though the write does not change its value.
0x06 No No No N RW
0x21 REV_ID 7:0 REV ID 0000 0000
0x00 No No No N R
0x22 GROUP_SID 7:4 GSID0[3:0] 0000 Primary Group Slave ID. N N N N RW
3:0 GSID1[3:0] 0000 Secondary Group Slave ID.
0x23 UDR_RST 7 UDR_RST 0 Reset all configurable non-RFFE Reserved registers to default values. The UDR_RST bit shall revert to default value of 0 after software reset is enabled.
0 Normal Operation N N N N RW
1 Software Reset
6:0 RESERVED 000 0000
Reserved for future use. Set to all 0.
0x24 ERR_SUM 7 RESERVED 0 Reserved for future error codes. The ERR_SUM register reports error codes until read. The ERR_SUM register shall reset after it is read. N N N N R
6 COMMAND_FRAME_PARITY_ERR
0 Command Sequence received with parity error – discard command. The ERR_SUM register shall reset after it is read.
5 COMMAND_LENGTH_ERR
0 Command length error. The ERR_SUM register shall reset after it is read.
4 ADDRESS_FRAME_PARITY_ERR
0 Address frame with parity error. The ERR_SUM register shall reset after it is read.
3 DATA_FRAME_PARITY_ERR
0 Data frame with parity error. The ERR_SUM register shall reset after it is read.
2 READ_UNUSED_REG 0 Read command to an invalid address. The ERR_SUM register shall reset after it is read.
1 WRITE_UNUSED_REG
0 Write command to an invalid address. The ERR_SUM register shall reset after it is read.
0 BID_GID_ERR 0 Read command with a BROADCAST_ID or GROUP_ID. The ERR_SUM register shall reset after it is read.
PRELIMINARY DATA SHEET SKY5®-8254-11 FRONT-END MODULE for LTE and NR
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 16 September 13, 2019 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 205315C
This Page Intentionally Blank
SKY5®-8254-11 FRONT-END MODULE for LTE and NR PRELIMINARY DATA SHEET
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com October 31, 2019 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 205315C 17
Package Dimensions Figure 2 is a mechanical drawing of the layout for the 30–pad SKY58254-11 module. Figure 3 provide a recommended PCB
layout footprint for the FEM to help the designer attain optimum thermal conductivity, good grounding, and minimum RF discontinuity for the 50–ohm terminals.
Figure 2. Dimensional Diagram for 3.0 x 5.0 x 0.7 mm 30-Pad Package – SKY58254-11
PRELIMINARY DATA SHEET SKY5®-8254-11 FRONT-END MODULE for LTE and NR
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 18 October 31, 2019 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 205315C
Figure 3. PCB Footprint Layout Diagram for 3.0 x 5.0 mm 30-Pad Package – SKY58254-11
SKY5®-8254-11 FRONT-END MODULE for LTE and NR PRELIMINARY DATA SHEET
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com October 31, 2019 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 205315C 19
Product DescriptionFigure 4 shows the pad labels and the pad numbering convention which starts with pad 1 in the lower left corner as indicated, and increments counter-clockwise around the package. Table 6
shows the pad name and functions. Figure 5 illustrates typical case markings.
Figure 4. SKY58254-11 Pad Configuration – 30–pad MCM (Top View)
Table 11. SKY58254-11 Pad Nam and Functions
Pad No.1 Pad Name Function
3 RX_OUT RX output port 9 VCC2 VCC2/ET/APT SUPPLY
11 VCC1 VCC1/ET/APT SUPPLY 13 VBATT 3.15V switch/bias supply 15 TXIN TX input port 17 VIO 1.8V TX RFFE VIO 18 SCLK TX RFFE clock 19 SDATA TX RFFE data 21 CPL_IN Coupler input port 23 CPL_OUT Coupler output port 25 TRX_OUT TRX output/antenna port
¹ Pads 1,2,4–8,10,12,14,16,20,22,24,26 and 30 are GROUND pads.
Figure 5. SKY58254-11 Typical Case Marking
Package Handling Information Because the device package is sensitive to moisture absorption, it is baked and vacuum packed before shipping. Instructions on the shipping container label regarding exposure to moisture after the container seal is broken must be followed. Otherwise, problems related to moisture absorption may occur when the part is subjected to high temperature during solder assembly.
The SKY58254-11 is rated to Moisture Sensitivity Level 3 (MSL3) at 260 °C. It can be used for lead or lead–free soldering. For additional information, refer to Skyworks Application Note, PCB Design and SMT Assembly/Rework Guidelines for MCM–L package, Document Number 101752.
Care must be taken when attaching this product, whether it is done manually or in a production solder reflow environment. Refer to Standard SMT Reflow Profile JEDEC Standard J–STD–020.
Production quantities of this product are shipped in a standard tape and reel format.
PRELIMINARY DATA SHEET SKY5®-8254-11 FRONT-END MODULE for LTE and NR
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com 20 October 31, 2019 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 205315C
Electrostatic Discharge Sensitivity
To avoid damage, both latent and visible, it is very important that the product assembly and test areas follow the handling precautions listed.
Personnel Grounding Facility - Wrist Straps - Relative Humidity Control and Air Ionizers - Conductive Smocks, Glove and Finger Cots - Dissipative Floors (less than 1,000 M to GND) - Antistatic ID Badge
Protective Workstation Protective Packaging and Transportation - Dissipative Table Top - Bags and Pouch (Faraday Shield) - Protective Test Equipment (Properly Grounded) - Protective Tote Box (Conductive Static Shielding) - Grounded Tip Soldering Irons - Protective Trays - Solder Conductive Suckers - Grounded Carts - Static Sensors - Protective Work Order Holders
SKY5®-8254-11 FRONT-END MODULE for LTE and NR PRELIMINARY DATA SHEET
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com October 31, 2019 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 205315C 21
Ordering Information
Part Number Part Description Evaluation Board Part Number
SKY58254-11 Front-End Module
Revision History
Revision Date Description
A July 29, 2019 Initial Release – Preliminary Information CN 30120
B September 13, 2019 Revise: Table 10 (Register Map); add Tables 5–9; CN 36752 Replace: Figs 2 & 3.
C October 31, 2019 Revise: Removed “and Confidential” from footer and TBDs to publish to external web site CN
Reference Skyworks Application Note: PCB Design and SMT Assembly/Rework Guidelines for MCM–L Package; Document Number 101752
Standard SMT Reflow Profile: JEDEC Standard J-STD-020
Electrostatic Discharge Sensitivity (D) Testing: JEDEC Standard, JD22-A114 Human Body Model (HBM)
Electrostatic Discharge Sensitivity (D) Testing: JEDEC Standard, JD22-A115 Machine Model (MM)
Electrostatic Discharge Sensitivity (D) Testing: JEDEC Standard, JD22-C101 Charged Device Model (CDM).
Testing and Measurement Technique-Electrostatic Discharge Immunity Test, IEC 61000-4-2
Copyright © 2018, 2019, Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc. or its subsidiaries in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference.