industrial training in telecom in delhi

Post on 27-Dec-2014

110 Views

Category:

Technology

0 Downloads

Preview:

Click to see full reader

DESCRIPTION

The leading Telecom training company in delhi offers job oriented telecom training and summer and industrial training with guaranteed job in leading telecom companies

TRANSCRIPT

1

Presentation on Site Master/Analyzer

Presented by :- W. Bhushan. B

2

Introduction to Site Analyzer

TOP VIEW OF SITE ANALYZER

RS-232 Printer port

RF Antenna port

Charging port

4

Selection Buttons

Operation Buttons 1 2 3

4 5 67 8 9

0 . +/-

ESC

Enter

Arrow Keys

Power Button

Night Vision Button

LED PWR ONLED Charging

DISPLAY

5

Requirement For VSWR & Return Loss Measurement

• Site Analyzer • Adapter(1/2”M to 7/8”F)• Dummy Load• Calibration Kit• Adapter• Site Analyzer Software• D-9 Serial Straight Cable

6

PROCEDURE

• Put ON the Site Analyzer by Press & hold ON/OFF Button.

• A screen appear on the display showing Serial No. & operating frequency range Etc.

• Screen resume to any mode in which it was switched OFF.

• Suppose the mode is Fault location.

Press & Hold ON/OFF Button

WELCOME SCREEN

Bird 2500 Ex780-2500 MHz

8

Fault location

Distance(m)450

-------

1

1.5Save/Recall

Auto Scale

Hold

------ 0

Calibration full

VSW

R

9

Rite now our Aim is measure VSWR So for measuring VSWR Mode should be Measure Match

1 2 3ESC

4 5 6

7 8 9ENTER

0 . +/-

Fault location Power

Night Vision

LED

Arrow Buttons

Numeric Keypad

Press Mode Button

VSW

R

10

Select Mode

Distance(m)450

-------

1

1.4Measure Match

Fault location

Measure Power

------ 0

Calibration full

VSW

R

11

Measure Match

Frequency(MHz)2500

-------

1

1.5Save/Recall

Auto Scale

Hold

------ 780

Calibration full

VSW

R

1 2 3ESC

4 5 6

7 8 9ENTER

0 . +/-

Fault location

Sele

ction

Butt

on

Power

Night Vision

LED

Arrow Buttons

Numeric Keypad

Press Config. button

VSW

R

12

13

Frequency(MHz)1880

-------

1

1.4Frequency

Limit

Hold

------ 1710

Press frequency button

Calibration full

VSW

R

Measure Match

14

Measure Match

Frequency(MHz)2500

-------

1

1.4Save/Recall

Auto Scale

Hold

------ 780

Start Freq 780Stop Freq 2500

Set the frequency by using Arrow Key or Numeric key pad

Calibration full

VSW

R1 2 3

ESC4 5 6

7 8 9ENTER

0 . +/-

15

2500

-------

1

1.4Save/Recall

Auto Scale

Hold

------ 780

Set the frequency

Start freq Stop freq

890

960

Frequency(MHz)

MHz

MHzCalibration full

VSW

R

ENTER

ESC

Measure Match

16

Frequency(MHz)960

-------

1

1.4Save/Recall

Auto Scale

Hold

------ 890

Start Freq 890 MHzStop Freq 960 MHz

Calibration OFF

VSW

R

Measure Match

17

To ON the calibration Press Calibration button

1 2 3ESC

4 5 6

7 8 9ENTER

0 . +/-

Measure Match Power

Night Vision

LED

Arrow Buttons

Numeric Keypad

VSW

R

18

Frequency(MHz)960

-------

1

1.4Short

Open

Load

------ 890

Start Freq 890 MHzStop Freq 960 MHz

Calibration OFF

Connect calibration kit to Site Analyzer port

VSW

R

Measure Match

19

Calibration Kit

Load

LoadOpen

½”M

½”M

½”M

short

Open

Open / short /Load

21

Frequency(MHz)960

-------

1

1.4Short

Open

Load

------ 890

Start Freq 890 MHzStop Freq 960 MHz

Calibration OFF

Short changes to done

Now apply open to the port and press

OpenThe OPEN changes to done

At last apply Load to Site master port and

press load button

LOAD changes to done

VSW

R

Measure Matchapply Short to the

port and press Open

22

Frequency(MHz)960

-------

1

1.4Save/Recall

Auto Scale

Hold

------ 890

Start Freq 890 MHzStop Freq 960 MHz

Calibration full

VSW

R

Measure Match

Press Auto scale

23

1 2 3ESC

4 5 6

7 8 9ENTER

0 . +/-

Measure Match Power

Night Vision

LED

Arrow Buttons

Numeric Keypad

Press Marker

ACTIVATE Marker

VSW

R

24

Frequency(MHz)960

-------

1

1.4M1

OFF

-------

------ 890

Start Freq 890 MHzStop Freq 960 MHz

Calibration full

To Activate M1 the button OFF to

ACIVEVS

WR

Measure Match

ACTIVE

Like Wise We can Do this Up to Marker M6

ESC

25

Measure Match

Frequency(MHz)960

-------

1

1.4Save/Recall

Auto Scale

Hold

------ 890

Calibration full

M1

M1 925 1.18

VSW

R

26

1 2 3ESC

4 5 6

7 8 9ENTER

0 . +/-

Measure Match Power

Night Vision

LED

Arrow Buttons

Numeric Keypad

To Change the marker Position to top most point press UP key of

Arrow button

27

1 2 3ESC

4 5 6

7 8 9ENTER

0 . +/-

Measure Match Power

Night Vision

LED

Arrow Buttons

Numeric Keypad

To Change the marker to lowest point press

the down arrow

VSW

R

28

1 2 3ESC

4 5 6

7 8 9ENTER

0 . +/-

Measure Match Power

Night Vision

LED

Arrow Buttons

Numeric Keypad

Press the right and left key to move the marker left and right along the

trace.

VSW

R

29

Measure Match

960

-------

1

1.4Save/Recall

Auto Scale

Hold

------ 890

Calibration fullM1 910 1.45

VSW

R

Arrow Buttons

Press the right and left key to move the marker left and right along the

trace.

30

To find the fault location change the mode to Fault location

1 2 3ESC

4 5 6

7 8 9ENTER

0 . +/-

Measure Match Power

Night Vision

LED

Arrow Buttons

Numeric Keypad

Press Mode button

VSW

R

31

Distance(m)

-------

1

1.5Measure Match

Fault location

Measure Power

------

Calibration full

Press the Fault location button

VSW

R

SELECT MODE

32

Distance(m)450

-------

1

1.4Distance

Limit

------ 0

Calibration full

M1

Press the distance button

VSW

R

Fault Location

33

Distance(m)450

-------

1

1.4Distance

Limit

------ 0

Calibration full

M1

Start distance

Stop distance

Max distance

0

450

450

Change the Start/ stop distance by pressing the numeric key pad

VSW

R

Fault Location

1 2 3ESC

4 5 6

7 8 9ENTER

0 . +/-Numeric Keypad

ESC

34

Fault Location

Distance(m)50

-------

1

1.4Save/ Recall

Auto Save

Hold

------ 0

Calibration full

M1

M1 4.0 1.26

VSW

R

35

Fault Location

Distance(m)25

-------

1

1.4Save/ Recall

Auto Save

Hold

------ 0

Calibration full

M1

M1 10 1.37

To save the reading press save/recall button

The screen show as

VSW

R

36

T

P

Q

R

S

A F K P U Z * _

B G L Q V Space : =

C H M R W [ - ,

D I N S X ] / “

E J O T Y . + #

Press the button to write the name

The letter appear here

PQS

37

Fault Location

-------

Save

Recall

Edit

Delete

TV-1D 21/3/2013 10:45AM

Bhushan-1M 22/3/2013 04:07AM

To recall the traces press recall button

To edit the traces press Edit button

To delete the traces press Delete button

38

-------

Watt

-------

-------

------

Measure Power

40

Measure Power

-------

------

dBm

-------

------

FWD : 40 wREF : 0.2 w

50 W

0

Thank You !!

top related