industrial training in telecom in delhi

41
Presentation on Site Master/Analyzer 1 Presented by :- W. Bhushan. B

Upload: tech-vidhya

Post on 27-Dec-2014

110 views

Category:

Technology


0 download

DESCRIPTION

The leading Telecom training company in delhi offers job oriented telecom training and summer and industrial training with guaranteed job in leading telecom companies

TRANSCRIPT

Page 1: industrial training in telecom in delhi

1

Presentation on Site Master/Analyzer

Presented by :- W. Bhushan. B

Page 2: industrial training in telecom in delhi

2

Introduction to Site Analyzer

Page 3: industrial training in telecom in delhi

TOP VIEW OF SITE ANALYZER

RS-232 Printer port

RF Antenna port

Charging port

Page 4: industrial training in telecom in delhi

4

Selection Buttons

Operation Buttons 1 2 3

4 5 67 8 9

0 . +/-

ESC

Enter

Arrow Keys

Power Button

Night Vision Button

LED PWR ONLED Charging

DISPLAY

Page 5: industrial training in telecom in delhi

5

Requirement For VSWR & Return Loss Measurement

• Site Analyzer • Adapter(1/2”M to 7/8”F)• Dummy Load• Calibration Kit• Adapter• Site Analyzer Software• D-9 Serial Straight Cable

Page 6: industrial training in telecom in delhi

6

PROCEDURE

• Put ON the Site Analyzer by Press & hold ON/OFF Button.

• A screen appear on the display showing Serial No. & operating frequency range Etc.

• Screen resume to any mode in which it was switched OFF.

• Suppose the mode is Fault location.

Page 7: industrial training in telecom in delhi

Press & Hold ON/OFF Button

WELCOME SCREEN

Bird 2500 Ex780-2500 MHz

Page 8: industrial training in telecom in delhi

8

Fault location

Distance(m)450

-------

1

1.5Save/Recall

Auto Scale

Hold

------ 0

Calibration full

VSW

R

Page 9: industrial training in telecom in delhi

9

Rite now our Aim is measure VSWR So for measuring VSWR Mode should be Measure Match

1 2 3ESC

4 5 6

7 8 9ENTER

0 . +/-

Fault location Power

Night Vision

LED

Arrow Buttons

Numeric Keypad

Press Mode Button

VSW

R

Page 10: industrial training in telecom in delhi

10

Select Mode

Distance(m)450

-------

1

1.4Measure Match

Fault location

Measure Power

------ 0

Calibration full

VSW

R

Page 11: industrial training in telecom in delhi

11

Measure Match

Frequency(MHz)2500

-------

1

1.5Save/Recall

Auto Scale

Hold

------ 780

Calibration full

VSW

R

Page 12: industrial training in telecom in delhi

1 2 3ESC

4 5 6

7 8 9ENTER

0 . +/-

Fault location

Sele

ction

Butt

on

Power

Night Vision

LED

Arrow Buttons

Numeric Keypad

Press Config. button

VSW

R

12

Page 13: industrial training in telecom in delhi

13

Frequency(MHz)1880

-------

1

1.4Frequency

Limit

Hold

------ 1710

Press frequency button

Calibration full

VSW

R

Measure Match

Page 14: industrial training in telecom in delhi

14

Measure Match

Frequency(MHz)2500

-------

1

1.4Save/Recall

Auto Scale

Hold

------ 780

Start Freq 780Stop Freq 2500

Set the frequency by using Arrow Key or Numeric key pad

Calibration full

VSW

R1 2 3

ESC4 5 6

7 8 9ENTER

0 . +/-

Page 15: industrial training in telecom in delhi

15

2500

-------

1

1.4Save/Recall

Auto Scale

Hold

------ 780

Set the frequency

Start freq Stop freq

890

960

Frequency(MHz)

MHz

MHzCalibration full

VSW

R

ENTER

ESC

Measure Match

Page 16: industrial training in telecom in delhi

16

Frequency(MHz)960

-------

1

1.4Save/Recall

Auto Scale

Hold

------ 890

Start Freq 890 MHzStop Freq 960 MHz

Calibration OFF

VSW

R

Measure Match

Page 17: industrial training in telecom in delhi

17

To ON the calibration Press Calibration button

1 2 3ESC

4 5 6

7 8 9ENTER

0 . +/-

Measure Match Power

Night Vision

LED

Arrow Buttons

Numeric Keypad

VSW

R

Page 18: industrial training in telecom in delhi

18

Frequency(MHz)960

-------

1

1.4Short

Open

Load

------ 890

Start Freq 890 MHzStop Freq 960 MHz

Calibration OFF

Connect calibration kit to Site Analyzer port

VSW

R

Measure Match

Page 19: industrial training in telecom in delhi

19

Calibration Kit

Load

LoadOpen

½”M

½”M

½”M

short

Open

Page 20: industrial training in telecom in delhi

Open / short /Load

Page 21: industrial training in telecom in delhi

21

Frequency(MHz)960

-------

1

1.4Short

Open

Load

------ 890

Start Freq 890 MHzStop Freq 960 MHz

Calibration OFF

Short changes to done

Now apply open to the port and press

OpenThe OPEN changes to done

At last apply Load to Site master port and

press load button

LOAD changes to done

VSW

R

Measure Matchapply Short to the

port and press Open

Page 22: industrial training in telecom in delhi

22

Frequency(MHz)960

-------

1

1.4Save/Recall

Auto Scale

Hold

------ 890

Start Freq 890 MHzStop Freq 960 MHz

Calibration full

VSW

R

Measure Match

Press Auto scale

Page 23: industrial training in telecom in delhi

23

1 2 3ESC

4 5 6

7 8 9ENTER

0 . +/-

Measure Match Power

Night Vision

LED

Arrow Buttons

Numeric Keypad

Press Marker

ACTIVATE Marker

VSW

R

Page 24: industrial training in telecom in delhi

24

Frequency(MHz)960

-------

1

1.4M1

OFF

-------

------ 890

Start Freq 890 MHzStop Freq 960 MHz

Calibration full

To Activate M1 the button OFF to

ACIVEVS

WR

Measure Match

ACTIVE

Like Wise We can Do this Up to Marker M6

ESC

Page 25: industrial training in telecom in delhi

25

Measure Match

Frequency(MHz)960

-------

1

1.4Save/Recall

Auto Scale

Hold

------ 890

Calibration full

M1

M1 925 1.18

VSW

R

Page 26: industrial training in telecom in delhi

26

1 2 3ESC

4 5 6

7 8 9ENTER

0 . +/-

Measure Match Power

Night Vision

LED

Arrow Buttons

Numeric Keypad

To Change the marker Position to top most point press UP key of

Arrow button

Page 27: industrial training in telecom in delhi

27

1 2 3ESC

4 5 6

7 8 9ENTER

0 . +/-

Measure Match Power

Night Vision

LED

Arrow Buttons

Numeric Keypad

To Change the marker to lowest point press

the down arrow

VSW

R

Page 28: industrial training in telecom in delhi

28

1 2 3ESC

4 5 6

7 8 9ENTER

0 . +/-

Measure Match Power

Night Vision

LED

Arrow Buttons

Numeric Keypad

Press the right and left key to move the marker left and right along the

trace.

VSW

R

Page 29: industrial training in telecom in delhi

29

Measure Match

960

-------

1

1.4Save/Recall

Auto Scale

Hold

------ 890

Calibration fullM1 910 1.45

VSW

R

Arrow Buttons

Press the right and left key to move the marker left and right along the

trace.

Page 30: industrial training in telecom in delhi

30

To find the fault location change the mode to Fault location

1 2 3ESC

4 5 6

7 8 9ENTER

0 . +/-

Measure Match Power

Night Vision

LED

Arrow Buttons

Numeric Keypad

Press Mode button

VSW

R

Page 31: industrial training in telecom in delhi

31

Distance(m)

-------

1

1.5Measure Match

Fault location

Measure Power

------

Calibration full

Press the Fault location button

VSW

R

SELECT MODE

Page 32: industrial training in telecom in delhi

32

Distance(m)450

-------

1

1.4Distance

Limit

------ 0

Calibration full

M1

Press the distance button

VSW

R

Fault Location

Page 33: industrial training in telecom in delhi

33

Distance(m)450

-------

1

1.4Distance

Limit

------ 0

Calibration full

M1

Start distance

Stop distance

Max distance

0

450

450

Change the Start/ stop distance by pressing the numeric key pad

VSW

R

Fault Location

1 2 3ESC

4 5 6

7 8 9ENTER

0 . +/-Numeric Keypad

ESC

Page 34: industrial training in telecom in delhi

34

Fault Location

Distance(m)50

-------

1

1.4Save/ Recall

Auto Save

Hold

------ 0

Calibration full

M1

M1 4.0 1.26

VSW

R

Page 35: industrial training in telecom in delhi

35

Fault Location

Distance(m)25

-------

1

1.4Save/ Recall

Auto Save

Hold

------ 0

Calibration full

M1

M1 10 1.37

To save the reading press save/recall button

The screen show as

VSW

R

Page 36: industrial training in telecom in delhi

36

T

P

Q

R

S

A F K P U Z * _

B G L Q V Space : =

C H M R W [ - ,

D I N S X ] / “

E J O T Y . + #

Press the button to write the name

The letter appear here

PQS

Page 37: industrial training in telecom in delhi

37

Fault Location

-------

Save

Recall

Edit

Delete

TV-1D 21/3/2013 10:45AM

Bhushan-1M 22/3/2013 04:07AM

To recall the traces press recall button

To edit the traces press Edit button

To delete the traces press Delete button

Page 38: industrial training in telecom in delhi

38

-------

Watt

-------

-------

------

Measure Power

Page 39: industrial training in telecom in delhi
Page 40: industrial training in telecom in delhi

40

Measure Power

-------

------

dBm

-------

------

FWD : 40 wREF : 0.2 w

50 W

0

Page 41: industrial training in telecom in delhi

Thank You !!