Tech Vidhya is the premier IT and Telecom training institute of India that is running its quality training courses since last decade and we deliver what we promise. Tech Vidhya is the leading training institute in telecom and IT sector that offers various Telecom, telecommunication, Networking and IT/Software courses in an efficient and friendly manner. We are having the highly qualified and experienced trainers for all the courses. The trainers are updated with the latest technologies and they are working on various live projects on India’s top telecom/IT companies.TRANSCRIPT
Kallol Ghosh
Submitted by: Kallol Ghosh
1
A Presentation About Outdoor Installation
Kallol Ghosh
INTRODUCTION
2
A cell site is a site where antennas and electronic communications equipment are placed, usually on a tower or other high place, to create a cell (or adjacent cells) in a cellular network. Cellular (cell) phones first became widely available in the United States in the 1990s, but since then their use has increased dramatically. The widespread use of cell phones has led to cell phone towers being placed in many communities. These towers, also called base stations, have electronic equipment and antennas that receive and transmit radio frequency (RF) signals. According to the RF Plan we have to install the antenna at a proper height on tower. Installation procedure is different for many others company, but there are no any complexity regarding that installation. In case of Nokia Siemens Network they don’t use any loop or bend on RF cable. Reliance don’t use any Jumper cable for a cell site. In this presentation we have discussed about the installation procedure and quality point of outdoor equipments.
Kallol Ghosh
INDEX
3
TITTLEInstallation & Quality Point
PAGE NO
RF Plan & Requirement List 4-5
Antenna Line 6
Antenna Installation & Quality Point
7-11
Jumper cable Installation & Quality Point
12-16
RF Cable & Connector Installation & Quality Point
17-23
Weather Proofing Kit 24-25
Earthing kits 26-29
Roxtec 30-31
Surge Arrestors 32
Cable ties 34
Labels 35
Kallol Ghosh
RF PLAN:
4
Name: Kallol Ghosh
RF PLANSITE NAME : TECHNO CENTRE
SITE ID : A234M08
ADDRESS : 35, B.C.ROAD, BURDWAN,W.B.
PARTICULARSSITE 1 SITE 2 SITE 3
AZIMUTH60° 180° 300°
HEIGHT 40m 44m 48m
MECHANICAL TILT 0° 0° 0°
ElECTRICAL TILT 3° 6° 2°
TYPE OF THE ANTENNA X43210 X01234 X21034
Requirement List :
5
particulars Specification Status
1.Antenna GSM900 Panel Antenna,65°beam width , cross polarized antenna
3
Jumper Cable 1/2" diameter, 1m, 3m, 7/8"M & 7/8"F connector
12
RF Cable or Feeder Cable
7/8", copper RF Cable 300m
RF Connector 7/8”M 12
Earthing Kits Copper strips, Ring type copper lugs 12
RF Clamps, cable ties Six way 35,100
Grounding Cable 35sq.mm. y-green grounding cable,16sq.mm. green grounding cable
108m8m
Roxtec and Screw 4 way, Full thread steel screw 1,8
Surge Arrestors ------- 6
Weather Proofing Kits PVC(6cm),Rubber,Butyl 3
Labels 100
Kallol Ghosh
Antenna Line:
6
Antenna
Jumper cable
Rf to jumper connector
Earthing kit
Rf clamp
Rf cable
Roxtec
Cable tray
Egb
The line between the Antenna and the BTS is known as antenna line
In antenna line there are following things:
• Rf cable• Rf connector• Jumper cable• Earthing kit• Weather proofing kit• Roxtec• Surge Arrester
Kallol Ghosh
:PROCEDURE TO INSTALL AN ANTENNA
7
First we have to make the connection between antenna port and jumper cable and connection should be weather proofed, and other end of jumper cable should be covered by polythene. If we give mechanical tilt then it should be done at bellow, electrical tilt should be avoided at this condition because, it should be change by touching the tower body.
Kallol Ghosh
ANTENNA INSTALLATION :
8
We have to take the antenna up on tower with the help of pulley or rope Keep the antenna away from tower body by pulling the rope carefully.
Kallol Ghosh
BTS
9
According to the RF Plan we have to set the antenna at proper height with the pole mount by using the antenna clamps with the appropriate electrical tilt. Antenn
a
Jumper ConnectorJumper Cable
35sqmm yellow green grounding cable
VCT
RF connector & Jumper connectorEarthing
Kits
EGB
RF Cable
HCT
Earthing kit
S-bend
Surge Arrestor
I/D Jumper cable
IGB EGB
Kallol Ghosh
Quality Check Point Of Antenna
10
Height of the antenna as per the RF Plan
Tilt of the antenna as per the RF Plan
Type of the antenna as per the RF Plan
Azimuth of the antenna as per the RF Plan
All the nuts bolts of the antenna should be properly
Lock nuts should be provided
Label should be provided of the back of the antenna
Electrical tilt
Mechanical tilt
Nuts bolts or lock nuts
Kallol Ghosh11
Label should be provided of the back of the antenna
Type of the antenna as per the RF Plan
GSM 900 Antenna
Single port antenna Dual port antenna
Hex port antenna
Quad port Antenna
Kallol Ghosh
Specification of Jumper Cable:
12
Size - ½ inches Inner core – Pure copper
cylindrical tube of ½ inches filled with Aluminum.
Outer core – Pure Copper cylindrical tube like spring.
Soft Insulation – White soft foam.
Hard outer insulation – Black insulation material.
Impedance – 50Ω. Flexibility- High. Length- 1m ,1.5m, 2m, 2m.5m,
3m, 5m, 7 m,10m, 15m.
Inner core
Soft insulation
Outer Core
Outer insulation
Kallol Ghosh
JUMPER CABLES INSTALLATION :
13
Jumper cable
RF connector
RF Cable
Now routing the outdoor jumper cable properly by using the cable ties and connects it to the RF Cable by using the 7/8”M RF connector. Indoor Jumper should b connected with BTS port.
Kallol Ghosh
Combination of connector in Jumper cable:
14
1. 7/8 F – 7/8 M2. 7/8 M – 7/8 M3. 7/8 F – 7/8 F4. 7/8 M – 7/8 L.M5. 7/8 M -7/8 L.M
Apart from these some more arrangements are
1. 7/8 M – 7/16 M2. 7/8 M – 7/16 F3. 7/8 F – 7/16 M4. 7/8 F – 7/16 F
Outdoor jumper cable – 3mIndoor jumper cable - 1 or 1.5 m
½” Jumper cable
Kallol Ghosh
Quality Check Point Of Jumper Cable:
15
In case of U-Loop of both jumper cable should be parallel
There should not be any sharp bend in the jumper cable
In case of close loop there should be two cable ties at the touching point
Routing of Jumper cable should be done by using cable ties
Distance of the two cable ties should be uniform and approx 200mm.
At the bend in the Jumper cable at least two cable ties should be provided at touching edge
Parallel U-loop
Close loop
Cable ties
Cable ties
Kallol Ghosh16
Labeling should be done with both the end of jumper cable
Routing of Jumper cable should be together and along with the tower body
Termination of Jumper cable should be verified by VSWR measurement
Last hand of PVC tape should be bottom to top
Labeling on Indoor jumper cable
Proper taping on jumper connector
Kallol Ghosh
Specification Of RF Cable:
17
• Size of the inner core is equal to the size of normal co-axial cable.
• As it’s a hollow , so it increase surface, decrease resistance, increase capacity, increase flexibility, lesser cost
• Inner Core : Pure Copper.• Soft Insulation : Fume• Outer Core : Pure Copper Cylindrical Tube.• Outer Insulation : Hard Insulation , black in
color.• Size Of The Cable : diameter 5/4” or 7/5”• Impedance : 50Ω
Feeder Cable
Inner core
Soft Insulation
Hard outer insulation
Outer core
Kallol Ghosh
RF CABLES INSTALLATION FIXING THE RF CABLES WITH RF CLAMP:
18
Cable tray
RF clamp
Weather proofing tape
After that we have to place the RF Cable sector wise on the cable tray by using the RF Clamp (6-way), and mark on the RF Cable according to the sector .
Kallol Ghosh
RF Clamp:
19
1 way RF clamp
2 way RF clamp
3 way RF clamp
6 way RF clamp
C-clamp made of GI
Dummy clamp
Kallol Ghosh20
Now the bending portion of RF cable should be carefully placed by using a dummy clamp at the junction point between VCT and HCT. Then another earthing kit should be attached along with RF cable by using the cable ties and then RF cable should be placed on HCT by using the RF clamp. Earthing kit should be straight to the shelter and connect the grounding cable with EGB properly
Bending portion of RF cable
EGB
Roxtec HCT
RF Cable
RF CABLES ConnectorCONNECTION BETWEEN RF AND JUMPER:
Quality Point:
Kallol Ghosh21
Routing of RF cable through the RF clam should be according to the sector, there should not be any cross routing of RF cable.
Connection should be made properly and attach the weather proofing tape properly
Connection should be made by hand tight.
Kallol Ghosh
RF Connector :
22
Base Outer
Port
BaseOuter
7/8’’ female connector7/8’’ male connector
Kallol Ghosh
Quality Point Of RF Cable:
23
There should be a label on RF Cable near RF to Jumper cable, and RF and Roxtec
Position of RF Clamp should be uniform from the either edge of cable tray
Routing of RF cable should be in pair and parallel
Distance of the two RF Clamp should be 0.9 or 0.6 on HCT.
Labeling of RF cable in side the shelter and outside the shelter should be visible from bottom
Routing of RF cable through the RF clamp should be according to the sector, there should not be any cross routing of RF Cable.
Bending of RF Cable should be greater than 300mm
S-Bend on RF Cable should be properly
Labeling on RF cable
S-bend
Parallel Routing
No cross routing, Sector wise place
Kallol Ghosh
WEATHER PROOFING
24
All ourdoor antenna line connections, grounding kits and wall entries have to be weather proofed. Connections where weather proofing is needed:
Feeder to jumper at antenna end. Feeder to antenna
• Direction of last hand of PVC tape should be bottom to top.
PVC Tape
Kallol Ghosh
WEATHER PROOFING:
25
FEEDERS WEATHER PROOFING KIT (BUTYL TAPE,3/4” PVC TAPE & ,2” PVC TAPES ), THESE ARE SET OF ONE KIT
1.Connection should be tape using PVC tape.
2.Connection should be sealed by using Rubber tape.
3.Connection to be tape by using PVC tape again.
Kallol Ghosh
EARTHING KITS & GROUNDING CABLE:
26
Earthing Kit
External Jumper
Feeder Cable
Antenna
Grounding Bar
(Normally 1.5m, - see Appendix 2)
200mm < d < 2000mm
d
Jumper Cable orAntenna Connector
Ground Cable to MainSite Ground System
Ground Cable (Tail)600mm long
RF Cable
Note: Grounding bar should be fixed directlyto the tower where the tower is itselfthe main ground down-conductor!
Ground Cable to MainSite Ground System
Alternative Orientationfor Grounding Bar
Earthing Kit
Jumper Cable orAntenna Connector
Kallol Ghosh
EARTHING KITS
27
EARTHING STRIP & CABLE
All earthing kits should be attached bellow 1m from lowest RF connector, along with the RF Cable in same position on VCT by using the cable ties, and earthing kits should be connected to EGB. EGB should be grounded properly.
Kallol Ghosh28
EARTHING KIT ,(IT INCLUDESEARTHING STRIP,CABLE,WEATHER-PROOFING KIT).
1.The earthing kit must always be taken together with RF Cable.2.All earthing kits should be made in same location.3.One earthing kits should be terminated to the one hole of EGB.
Kallol Ghosh
Lugs & Strips :
29
Copper strip
Aluminum strip
There are three types of lugs 1) I-type 2) Pin type 3) Ring type
Strips and lugs should be same material.
Kallol Ghosh
Roxtec: Quality point
30
1. Arrangement of RF Cable should be sector wise.2. Routing of RF Cable should not be crossed with
each others3. 4 Robber boots are there, each and every boot
present a hole.4. Corner should be sealed by using silicon gel5. Full thread steel screw of size 1-1.5” should be
used
Kallol Ghosh31
RF Cable should be entered into the roxtec and mark the position of RF Cable then it should be removed from roxtec and cut the mark point on RF cable and connect the 7/8”M connector. Now finally we insert the RF cable into the roxtec and connect it with Surge arrestors in same location according to sector wise. After that we have to make an s-bend on RF Cable near the roxtec.
Kallol Ghosh
Surge Arrestors:
32
Position of all the surge arrestors are in same.
Now other end of surge arrestors should be connected with indoor jumper cable and route it on the indoor cable tray by using the cable ties.
Kallol Ghosh
Quality Point Of Surge Arrestor :
33
All the termination of Surge arrestors and jumper cable should be hand tight
Position of all Surge arrestors should be in same size
Grounding cable termination on surge arrestors should be properly tight.
Routing of Grounding cable should be along with the same RF Cable.
Position of Grounding cable should be bottom of the RF Cable.
Each Grounding cable should be terminated to EGB.
Same position
Grounding cable bottom of the RF cable
Along with RF cable
Cable Ties: Quality Point
Kallol Ghosh34
1. Routing of Jumper cable should be done by using cable ties
2. Distance of two cable ties should be uniform and approx 200mm to route a jumper cable
3. Position of knot and direction of knot for cable ties should be in same .
4. Unused portion of cable ties should be cut on
Kallol Ghosh
Labels: Quality Point:
35
1.Labelling on the RF Cable in both inside and outside the shelter should be visible from bottom.2.Labels should be provided at the both end of jumper cable.3.It should be provided of the back of the antenna.
Kallol Ghosh