1 : 250 planning - brent cross€¦ · glazed curtain wall panels grc panels stone plinth opaque...
Post on 01-May-2020
6 Views
Preview:
TRANSCRIPT
NB-LG0
NB-UG0
NB-010
NB-020
NB-RF1Sign
Sign
Sign
Sign
Sign
CeramicPanels
Glazed CurtainWall Panels
Stone PlinthFenestration
Glazed CurtainWall Panels
Fenestration
Service Entrance
NB-LG0
NB-UG0
NB-010
NB-020
NB-B10
NB-RF1
Sign
Service Yard
Sign
Sign
Sign
SignSignCeramic Panels
Glazed Curtain Wall Panels
GRC Panels
Fenestration
Stone Plinth
Sign
CALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 250
29/0
3/20
17 1
8:30
:09
P4
PLANNING
SOUTHERNDEPARTMENT - NORTH &SOUTH ELEVATIONS
50-14026
08069-CRL-SD-XXX-DR-P-20121
01/31/17
NG
LM
Brent Cross Phase1B (North) RMA
0 2.5m 5m 10m 25m
2
1
1 : 250SOUTHERN DEPARTMENT - SOUTH ELEVATION2
1 : 250SOUTHERN DEPARTMENT - NORTH INTERNAL ELEVATION1
REV NO. DATE DESCRIPTIONP1 10/02/17 RMA Draft Issue for CommentP2 06/03/17 RMA Draft 2P3 17/03/17 RMA Draft 3P4 29/03/17 RMA Final Issue
North Internal Elevation
2.0 RETAIL & HOTEL PLOTS, BRENT CROSS MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE
128
2.0 RETAIL & HOTEL PLOTS, BRENT CROSS MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE
129
2.0 RETAIL & HOTEL PLOTS, BRENT CROSS MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE
130
NB-LG0
NB-UG0
NB-010
NB-020
NB-B10
NB-RF1
North Circular Road
Living Bridge
Sign
Sign Sign
Sign SD LG
Service Yard
Ceramic Panels
Glazed Curtain Wall Panels
GRC PanelsStone Plinth
Opaque Glazing
NB-LG0
NB-UG0
NB-010
NB-020
NB-RF1
North Circular Road
Living Bridge
Sign
Ceramic Panels
Glazed Curtain Wall Panels
GRC Panels
Fenestration
Stone Plinth
Energy Centre
Collect by Car
CALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 250
29/0
3/20
17 1
8:29
:43
P4
PLANNING
SOUTHERNDEPARTMENT- EAST &WEST ELEVATIONS
50-14026
08069-CRL-SD-XXX-DR-P-20120
01/31/17
NG
LM
Brent Cross Phase1B (North) RMA
0 2.5m 5m 10m 25m
1
2
1 : 250SOUTH DEPARTMENT - EAST ELEVATION1
1 : 250SOUTHERN DEPARTMENT - WEST ELEVATION2
REV NO. DATE DESCRIPTIONP1 10/02/17 RMA Draft Issue for CommentP2 06/03/17 RMA Draft 2P3 17/03/17 RMA Draft 3P4 29/03/17 RMA Final Issue
East Elevation
2.0 RETAIL & HOTEL PLOTS, BRENT CROSS MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE
131
LEVEL 01
LEVEL 01
ROOF
LEVEL LG
100
100
4040
500 10 250 10 250 10 500 10 250 10 250 10 4402500
280
O N E M O D U L E
LEVEL 02
100
100
40
500 10 250 10 250 10 500 10 250 10 250 10 4402500
280
M O D U L E with integrated glazing
Type 1 – Ceramic panelsRainscreenGlazed ceramic panels be the primary building facade material that is used as a rainscreen system.
A range of panel sizes, colours and profiles work to create a textured coloured surface.
Glazed ceramic panels have properties that include:
• Timeless – Ceramic panel facades enjoy a long lasting appeal. Through detailing and colour choices they can create impact and provide a contemporary that compliments steel and glass
• Sustainable – Excellent BREEAM Rating. Clay facades are made of natural resources and are highly energy efficient due to the property of thermal insulation
• Maintenance free – These clay facade panels once installed, are easy on maintenance
• Durability – Their weather resistance power makes them highly durable which last for decades. They can be fragile and may not sustain high impacts which is why they are located on the higher levels only. They also offer coloured panels that are resistant to fading
It is envisaged that light fixtures can also be incorporated into the facade system to create a dynamic facade in the evening.
NB-LG0
NB-UG0
NB-010
NB-020
NB-RF1
M-F M-E
408069-CRL-SD-XXX-DR-P-40102
Ceramic Panels
GRC Panels
Abutment
Stone Plinth
Ceramic Panels
GRC Panels
Stone Plinth
NB-LG0
NB-UG0
NB-010
NB-020
NB-RF1
M-7
208069-CRL-SD-XXX-DR-P-40102
Ceramic Panels
Glazed Curtain Wall Panels
Fenestration
GRC PanelsStone Plinth
Ceramic Panels
Glazed Curtain Wall Panels
GRC Panels
Stone PlinthCALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 100
29/0
3/20
17 1
8:33
:56
P3
PLANNING
SOUTHERNDEPARTMENTENLARGED ELEVATION &SECTION
50-14026
08069-CRL-SD-XXX-DR-P-40102
02/23/17
NG
NS
Brent Cross Phase1B (North) RMA
21
1 : 100SOUTHERN DEPARTMENT - ENLARGED WEST ELEVATION3 1 : 100
SOUTHERN DEPARTMENT - WEST ENLARGED SECTION4 1 : 100SOUTHERN DEPARTMENT - SOUTH ELEVATION1 1 : 100
SOUTHERN DEPARTMENT - ENLARGED SECTION2
34
0 1m 2m 4m 10m
REV NO. DATE DESCRIPTIONP1 06/03/17 RMA Draft 2P2 17/03/17 RMA Draft 3P3 29/03/17 RMA Final Issue
LEVEL 01
LEVEL 01
ROOF
LEVEL LG
100
100
4040
500 10 250 10 250 10 500 10 250 10 250 10 4402500
280
O N E M O D U L E
LEVEL 02
100
100
40
500 10 250 10 250 10 500 10 250 10 250 10 4402500
280
M O D U L E with integrated glazing
2.0 RETAIL & HOTEL PLOTS, BRENT CROSS MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE
132
LEVEL 01
LEVEL 01
ROOF
LEVEL LG
100
100
4040
500 10 250 10 250 10 500 10 250 10 250 10 4402500
280
O N E M O D U L E
LEVEL 02
100
100
40
500 10 250 10 250 10 500 10 250 10 250 10 4402500
280
M O D U L E with integrated glazing
TYPE 1 – Profiled Ceramic panels
TYPE 2 – Glazed Curtain Wall panels
TYPE 1 – Profiled Ceramic panels
TYPE 3 – GRC panels
TYPE 1 – Profiled Ceramic panels
TYPE 2 – Glazed Curtain Wall panels
TYPE 3 – GRC panels
Type 1 – Ceramic panels
2.0 RETAIL & HOTEL PLOTS, BRENT CROSS MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE
133
Type 2 – GRC PanelsRainscreenThe lower sections of the facade along the northern, southern and western facades will consist of GRC panels.
GRC panels are more robust and better suited to accessible zones. GRC offers many advantages that include:
• Versatile – offers unrivalled creativity with the ability to accurately reproduce any small or large design, including historic ornaments, ornate patterns and complex shapes. It can also match other materials such as stone which is what we would be looking for in this instance.
• Durable – The weathering characteristics of GRC are as good as any precast material but lighter. Unlike traditional reinforced cement, GRC uses alkali resistant (AR) glass fibres throughout the matrix to provide reinforcement so is not at risk of corrosion and does not require further maintenance. The GRC can be enhance for greater protection and durability, with a wide range of specialised products available that offer additional resistance to impact, weather, graffiti and water.
• Sustainable – GRC is generally cast in thin skin sections which consume less raw materials and energy during manufacture. Consequently, the reduced weight and thickness of GRC panels can provide significantly lower environmental impacts during transportation to site and during installation.
• Lightweight and Strong-The reduced weight of panels makes them easier and cheaper to handle with reduced transportation costs
Type 3 – Glazed Curtain Wall RainscreenThere are various area of glazed curtain walling. Based on its location and function can be described as follows:
• Glazing to Level 02 Restaurants – Curved sections of clear glass panels to restaurants.
• Glazing to Back of House Staff areas – These occur in small sections within the Ceramic panel facades. Film or frit will allow natural light into the area whilst limiting views into the BOH area.
• Glazing to Eastern Facade – It is envisaged that two layers of frit will be applied to these panels with varying density and colour. This creates interesting patterns as you move around the building. It also helps vary the translucency depending on the use.
2.0 RETAIL & HOTEL PLOTS, BRENT CROSS MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE
134
NB-LG0
NB-UG0
NB-010
NB-020
NB-RF1
M-4M-5
208069-CRL-SD-XXX-DR-P-40101
Shopfronts by Tenant
Ceramic Panels
Fenestration
CeramicPanels
Shopfrontby Tenant
Fenestration
Roof
CeramicPanels
Glazed CurtainWall Panels
Lift Door
Lift Door
CeramicPanels
Opaque Glazing
GRC Panels
NB-LG0
NB-UG0
NB-010
NB-020
NB-RF1
408069-CRL-SD-XXX-DR-P-40101
Sign
SIGNSIGN
SIGN
CeramicPanels
Glazed Curtain Wall Panels
GRC Panels
Stone Plinth
Opaque Glazing
CALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 100
29/0
3/20
17 1
8:33
:02
P4
PLANNING
SOUTHERNDEPARTMENTENLARGED ELEVATION &SECTION
50-14026
08069-CRL-SD-XXX-DR-P-40101
02/20/17
NG
NS
Brent Cross Phase1B (North) RMA
1 : 100SOUTHERN DEPARTMENT - ENLARGED NORTH ELEVATION1 1 : 100
SOUTHERN DEPARTMENT -ENLARGED NORTH SECTION2
1
2
1 : 100SOUTHERN DEPARTMENT - ENLARGED EAST SECTION4
4
3
1 : 100SOUTHERN DEPARTMENT - ENLARGED EAST ELEVATION3
0 1m 2m 4m 10m
REV NO. DATE DESCRIPTIONP1 20/01/17 Stage 2 Issue Draft 3P2 06/03/17 RMA Draft 2P3 17/03/17 RMA Draft 3P4 29/03/17 RMA Final Issue
NB-LG0
NB-UG0
NB-010
NB-020
NB-RF1
M-4M-5
208069-CRL-SD-XXX-DR-P-40101
Shopfronts by Tenant
Ceramic Panels
Fenestration
CeramicPanels
Shopfrontby Tenant
Fenestration
Roof
CeramicPanels
Glazed CurtainWall Panels
Lift Door
Lift Door
CeramicPanels
Opaque Glazing
GRC Panels
NB-LG0
NB-UG0
NB-010
NB-020
NB-RF1
408069-CRL-SD-XXX-DR-P-40101
Sign
SIGNSIGN
SIGN
CeramicPanels
Glazed Curtain Wall Panels
GRC Panels
Stone Plinth
Opaque Glazing
CALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 100
29/0
3/20
17 1
8:33
:02
P4
PLANNING
SOUTHERNDEPARTMENTENLARGED ELEVATION &SECTION
50-14026
08069-CRL-SD-XXX-DR-P-40101
02/20/17
NG
NS
Brent Cross Phase1B (North) RMA
1 : 100SOUTHERN DEPARTMENT - ENLARGED NORTH ELEVATION1 1 : 100
SOUTHERN DEPARTMENT -ENLARGED NORTH SECTION2
1
2
1 : 100SOUTHERN DEPARTMENT - ENLARGED EAST SECTION4
4
3
1 : 100SOUTHERN DEPARTMENT - ENLARGED EAST ELEVATION3
0 1m 2m 4m 10m
REV NO. DATE DESCRIPTIONP1 20/01/17 Stage 2 Issue Draft 3P2 06/03/17 RMA Draft 2P3 17/03/17 RMA Draft 3P4 29/03/17 RMA Final Issue
2.0 RETAIL & HOTEL PLOTS, BRENT CROSS MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE
135
2.0 RETAIL & HOTEL PLOTS, BRENT CROSS MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE
2.3.4Proposals
Southern Department Store (M&S)GeneralThis building sits on the southern edge of the development between the living bridge and Tempelhof Bridge. It consists of 5 main levels; basement, lower ground, upper ground and the first floor are primarily the M&S accommodation. At lower ground the footprint is interrupted by the ramp connecting to the basement. At first floor there are escalators and a lift that connect to the leisure and restaurants at second floor and the mezzanine above. The roof allocates plant space for the M&S store and leisure uses.
GridAll levels 9m x 9m, 9m x 18m
LevelsThe floor to floor heights are different at each level, 6.2m, 5.5m and 5m above first floor. These are all slat slab construction to achieve the required clear headroom.
Service CoresThe M&S portion of the building is serviced by passenger and goods lifts to M&S’s specification. There are also two further passenger lifts giving access to the leisure levels; one directly off the living bridge and a second from the first floor street adjacent to the Tempelhof threshold and two escalators. There is also one service lift from the basement to the leisure levels.
Means of Escape There are a number of escape stair cores 2 dedicated to M&S and 3 dual use M&S and leisure.
Engineering ServicesA number of M&S service shafts pass through the leisure level to afford access to the roof plant areas. The leisure uses all have allocated plant space at roof level.
NotesThis building is highly prominent being visible from four sides and having a pedestrian interface with the living bridge. It will have a highly distinguishable façade treatment and visual marker for the scheme.
136
2.0 RETAIL & HOTEL PLOTS, BRENT CROSS MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE
BasementThe basement of plot 102 will be used the main servicing/ loading area that serves the whole of the new extension. It also houses the department store’s click and collect facility that is accessed externally by the public.
DN
UPUP
UP
M-1 M-2 M-3 M-4 M-5 M-6 M-7 M-8 M-9
M-G
M-F
M-E
M-D
M-C
M-B
M-A
M-10
M-H
M-I
M-J
M-K
M-L
Service Yard
MEP
MEPMEP
Service Yard
Service Yard
Service Yard
Service Yard
Service Yard
Service Yard
Service Yard
SD B1
SD B1
Water Tank
Water Tank
UPUP
CALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 250
29/0
3/20
17 1
8:42
:24
P4
PLANNING
SOUTHERNDEPARTMENT - GA PLAN- B1
50-14026
08069-CRL-SD-B10-DR-P-12013
02/06/17
NG
LM
Brent Cross Phase1B (North) RMA
0 2.5m 5m 10m 25m
REV NO. DATE DESCRIPTIONP1 10/02/17 RMA Draft Issue for CommentP2 06/03/17 RMA Draft 2P3 17/03/17 RMA Draft 3P4 29/03/17 RMA Final Issue
137
BUS STOP
STAN
STAND
BUSSTOP10
10
UP
UP
UPUP
UP
M-1 M-2 M-3 M-4 M-5 M-6 M-7 M-8 M-9
M-G
M-F
M-E
M-D
M-C
M-B
M-A
M-10
MSU 0 05SU 0 40
Bus Station
Energy Centre
Main Square
Tempelhof Avenue
Slope 1:10
SU 0 06
SU 0 07
SU 0 39
SU 0 38 SU 0 37
SU 0 36
SU 0 35
SU 0 37 A
SU 0 38 AFC 0 08
FCS 0 08
MEP
MEP
SU 0 09
MEP
MEP
MEP
Substation
SU 0 10
SU 0 11
SU 0 12
SU 0 13
SU 0 13 A
SU 0 05
Service Corridor 0 01
MEP
Stair 0 04
Abutment
Abutment
SD LG
SD CbC
SD CbC
08069-CRL-NB-LG0-DR-P-12401 08069-CRL-NB-LG0-DR-P-12401
080 69-CRL -NB-LG 0-DR- P-1240 2
CALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 250
29/0
3/20
17 2
0:03
:16
P4
PLANNING
SOUTHERNDEPARTMENT - GA PLAN- LEVEL LG
50-14026
08069-CRL-SD-LG0-DR-P-12014
02/06/17
NG
LM
Brent Cross Phase1B (North) RMA
0 2.5m 5m 10m 25m
REV NO. DATE DESCRIPTIONP1 10/02/17 RMA Draft Issue for CommentP2 06/03/17 RMA Draft 2P3 17/03/17 RMA Draft 3P4 29/03/17 RMA Final Issue
Lower Ground LevelThe Lower Ground Level of plot 102 predominantly consists of the first trading level of the department store. It is envisaged that this level will hold the food offering.
It also consists of the basement service ramp and a retail unit.
The main entrance point to the department store and retail units is through the Main Square. It also provides direct public entrance from the bus station.
There is a good provision of lifts that provide access from the bus station to the Living Bridge and direct lift access from the department store to the parking levels.
Pedestrian Access
Entrance
2.0 RETAIL & HOTEL PLOTS, BRENT CROSS MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE
138
Upper Ground LevelUpper Ground is occupied in its entirety by the second retail level of the department store. It has direct access from the Main Square upper walkways.
Internal vertical transportation, lifts and escalators, provide good connectivity between the levels.
Due to the level difference between Upper Ground Level and the Living bridge there is no direct access into the department store from its eastern facade. However there is provision for dedicated lift access to the Leisure and food and beverage units on Level 02.
Pedestrian Access
Entrance
M-1 M-2 M-3 M-4 M-5 M-6 M-7 M-8 M-9
M-G
M-F
M-E
M-D
M-C
M-B
M-A
M-10
SU 1 07SU 1 24
SU 1 25SU 1 26SU 1 27
SU 1 28
MEP
MEP
SU 1 23 B
SU 1 11
SU 1 10
SU 1 12
SU 1 09
SU 1 06SU 1 05 A
Main Square
Tempelhof AvenueSD UG
Living Bridge
Slop
e 1:21
Slop
e 1:30
Slop
e 1:24
Canopy
Slope 1:32
Slope 1:30
08069-CRL-NB-UG0-DR-P-12403 08069-CRL-NB-UG0-DR-P-12403
080 69-CRL -NB-UG 0-DR- P-1240 4
UP
Slope 1:30
Slope 1:30
SU 1 11
UP
UP
UP
UP
UP
CALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 250
29/0
3/20
17 1
8:43
:32
P4
PLANNING
SOUTHERNDEPARTMENT - GA PLAN- LEVEL UG
50-14026
08069-CRL-SD-UG0-DR-P-12015
02/06/17
NG
LM
Brent Cross Phase1B (North) RMA
0 2.5m 5m 10m 25m
REV NO. DATE DESCRIPTIONP1 10/02/17 RMA Draft Issue for CommentP2 06/03/17 RMA Draft 2P3 17/03/17 RMA Draft 3P4 29/03/17 RMA Final Issue
2.0 RETAIL & HOTEL PLOTS, BRENT CROSS MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE2.0 RETAIL & HOTEL PLOTS, MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE
139
UPDN
M-1 M-2 M-3 M-4 M-5 M-6 M-7 M-8 M-9
M-G
M-F
M-E
M-D
M-C
M-B
M-A
M-10
RS 2 09
RS 2 10
MEP
MEP
Room
Room
Room
RS 2 13 C
RS 2 14
RSS 2 13 C
RSS 2 14RSS 2 13 B
RSS 2 13 D
RS 2 37-M
RS 2 35
RSS 2 35
Shop Mobility
RS 2 36
RSS 2 36
Landlord's LV Switch Room
South CP01 L01
RSS 2 34
RSS 2 15
RS 2 15
RS 2 13 DRS 2 13 B
LE 2 05
RS 2 09
RS 2 08
SD 010
Main Square
08069-CRL-NB-010-DR-P-12405 08069-CRL-NB-010-DR-P-12405
080 69-CRL -NB-01 0-DR-P -12406
Circulation
CALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 250
29/0
3/20
17 1
8:27
:57
P4
PLANNING
SOUTHERNDEPARTMENT - GA PLAN- LEVEL 01
50-14026
08069-CRL-SD-010-DR-P-12016
02/06/17
NG
LM
Brent Cross Phase1B (North) RMA
0 2.5m 5m 10m 25m
REV NO. DATE DESCRIPTIONP1 10/02/17 RMA Draft Issue for CommentP2 06/03/17 RMA Draft 2P3 17/03/17 RMA Draft 3P4 29/03/17 RMA Final Issue
Pedestrian Access
Entrance
Level 01Level 01 is mainly occupied by the department store and is accessed from the Level 01 walkways off the Main square.
Internal vertical transportation, lifts and escalators, provide good connectivity between the levels.
The plot also consists of a circulation atrium with a lift and escalators that provides access to the Level 02 Leisure and Restaurants via their mezzanines on Level 03
2.0 RETAIL & HOTEL PLOTS, BRENT CROSS MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE
140
Level 02Level 02 consists of double height Leisure and F&B units. These units are accessed from their Mezzanines on Level 03.
DN
UP
DN
M-1 M-2 M-3 M-4 M-5 M-6 M-7 M-8 M-9
M-G
M-F
M-E
M-D
M-C
M-B
M-A
M-10
LE 3 02
BOH
RS 3 01 RS 3 02
M&S BOH
BOH
BOH
BOH
BOH
CommunityBOH
South CP L02
Hall A
RS 3 10-M
LE 3 05 LE 3 03
RSS 3 10 A-M
M&S BOH
South CP L02
Hall AHall A
08069-CRL-NB-020-DR-P-12407 08069-CRL-NB-020-DR-P-12407
080 69-CRL -NB-02 0-DR-P -12408
South CP02 Welcome Hall A
CALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 250
29/0
3/20
17 1
8:28
:12
P4
PLANNING
SOUTHERNDEPARTMENT - GA PLAN- LEVEL02
50-14026
08069-CRL-SD-020-DR-P-12017
02/06/17
NG
LM
Brent Cross Phase1B (North) RMA
0 2.5m 5m 10m 25m
REV NO. DATE DESCRIPTIONP1 10/02/17 RMA Draft Issue for CommentP2 06/03/17 RMA Draft 2P3 17/03/17 RMA Draft 3P4 29/03/17 RMA Final Issue
2.0 RETAIL & HOTEL PLOTS, BRENT CROSS MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE2.0 RETAIL & HOTEL PLOTS, MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE
141
Roof LevelThe roof area will predominantly be occupied by plant. It is envisaged that the roof finishes will predominantly be pavers and gravel.
M-1 M-2 M-3 M-4 M-5 M-6 M-7 M-8 M-9
M-G
M-F
M-E
M-D
M-C
M-B
M-A
M-10
M-H
Access zone for facademaintenance
Facade Cladding
08069-CRL-NB-RF1-DR-P-12411 08069-CRL-NB-RF1-DR-P-12411
080 69-CRL -NB-RF 1-DR- P-1241 2
CALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 250
29/0
3/20
17 1
8:46
:17
P4
PLANNING
SOUTHERNDEPARTMENT - GA PLAN- LEVEL ROOF
50-14026
08069-CRL-SD-RF1-DR-P-12019
02/06/17
NG
LM
Brent Cross Phase1B (North) RMA
0 2.5m 5m 10m 25m
REV NO. DATE DESCRIPTIONP1 10/02/17 RMA Draft Issue for CommentP2 06/03/17 RMA Draft 2P3 17/03/17 RMA Draft 3P4 29/03/17 RMA Final Issue
2.0 RETAIL & HOTEL PLOTS, BRENT CROSS MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE
142
Collect by Car
M-1
Energy Centre
Collect by Car
Tempelhof AvenueEnergy Centre
Collect by Car
M-C M-B M-A
Sign
Tempelhof AvenueEnergy Centre
Living Bridge
CALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 250
29/0
3/20
17 1
7:51
:32
P4
PLANNING
SOUTHERNDEPARTMENT COLLECTBY CAR
50-14026
08069-CRL-SD-LG0-DR-P-12021
01/16/17
NG
LM
Brent Cross Phase1B (North) RMA
3D VIEW4
1 : 250COLLECT BY CAR PLAN1
1 : 250COLLECT BY CAR ELEVATION 022
1 : 250CLICK AND COLLECT ELEVATION 013
12
REV NO. DATE DESCRIPTIONP1 10/02/17 RMA Draft Issue for CommentP2 06/03/17 RMA Draft 2P3 17/03/17 RMA Draft 3P4 29/03/17 RMA Final Issue
M-1
Energy Centre
Collect by Car
Tempelhof AvenueEnergy Centre
Collect by Car
M-C M-B M-A
Sign
Tempelhof AvenueEnergy Centre
Living Bridge
CALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 250
29/0
3/20
17 1
7:51
:32
P4
PLANNING
SOUTHERNDEPARTMENT COLLECTBY CAR
50-14026
08069-CRL-SD-LG0-DR-P-12021
01/16/17
NG
LM
Brent Cross Phase1B (North) RMA
3D VIEW4
1 : 250COLLECT BY CAR PLAN1
1 : 250COLLECT BY CAR ELEVATION 022
1 : 250CLICK AND COLLECT ELEVATION 013
12
REV NO. DATE DESCRIPTIONP1 10/02/17 RMA Draft Issue for CommentP2 06/03/17 RMA Draft 2P3 17/03/17 RMA Draft 3P4 29/03/17 RMA Final Issue
M-1
Energy Centre
Collect by Car
Tempelhof AvenueEnergy Centre
Collect by Car
M-C M-B M-A
Sign
Tempelhof AvenueEnergy Centre
Living Bridge
CALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 250
29/0
3/20
17 1
7:51
:32
P4
PLANNING
SOUTHERNDEPARTMENT COLLECTBY CAR
50-14026
08069-CRL-SD-LG0-DR-P-12021
01/16/17
NG
LM
Brent Cross Phase1B (North) RMA
3D VIEW4
1 : 250COLLECT BY CAR PLAN1
1 : 250COLLECT BY CAR ELEVATION 022
1 : 250CLICK AND COLLECT ELEVATION 013
12
REV NO. DATE DESCRIPTIONP1 10/02/17 RMA Draft Issue for CommentP2 06/03/17 RMA Draft 2P3 17/03/17 RMA Draft 3P4 29/03/17 RMA Final Issue
M-1
Energy Centre
Collect by Car
Tempelhof AvenueEnergy Centre
Collect by Car
M-C M-B M-A
Sign
Tempelhof AvenueEnergy Centre
Living Bridge
CALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 250
29/0
3/20
17 1
7:51
:32
P4
PLANNING
SOUTHERNDEPARTMENT COLLECTBY CAR
50-14026
08069-CRL-SD-LG0-DR-P-12021
01/16/17
NG
LM
Brent Cross Phase1B (North) RMA
3D VIEW4
1 : 250COLLECT BY CAR PLAN1
1 : 250COLLECT BY CAR ELEVATION 022
1 : 250CLICK AND COLLECT ELEVATION 013
12
REV NO. DATE DESCRIPTIONP1 10/02/17 RMA Draft Issue for CommentP2 06/03/17 RMA Draft 2P3 17/03/17 RMA Draft 3P4 29/03/17 RMA Final Issue
2.0 RETAIL & HOTEL PLOTS, BRENT CROSS MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE2.0 RETAIL & HOTEL PLOTS, MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE
143
NB-LG0
NB-UG0
NB-010
NB-020
NB-B10
NB-RF1 LE 4 02-M
Service Yard
BOH
SD 01
SD UG
SD LG
LE 3-02
NB-LG0
NB-UG0
NB-010
NB-020
NB-B10
NB-RF1
Service Yard
Circulation
SD UG
SD 01
CALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 250
29/0
3/20
17 1
9:03
:13
P4
PLANNING
SOUTHERNDEPARTMENT SECTIONSNORTH - SOUTH 01 & 02
50-14026
08069-CRL-SD-XXX-DR-P-30000
08/24/16
NG
LM
Brent Cross Phase1B (North) RMA
0 2.5m 5m 10m 25m
1 : 250NORTH-SOUTH SECTION - SOUTHERN DEPARTMENT1
1 : 250NORTH-SOUTH SECTION - SOUTHERN DEPARTMENT (RAMP)2
12
REV NO. DATE DESCRIPTIONP1 10/02/17 RMA Draft Issue for CommentP2 06/03/17 RMA Draft 2P3 17/03/17 RMA Draft 3P4 29/03/17 RMA Final Issue
Sections
NB-LG0
NB-UG0
NB-010
NB-020
NB-B10
NB-RF1 LE 4 02-M
Service Yard
BOH
SD 01
SD UG
SD LG
LE 3-02
NB-LG0
NB-UG0
NB-010
NB-020
NB-B10
NB-RF1
Service Yard
Circulation
SD UG
SD 01
CALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 250
29/0
3/20
17 1
9:03
:13
P4
PLANNING
SOUTHERNDEPARTMENT SECTIONSNORTH - SOUTH 01 & 02
50-14026
08069-CRL-SD-XXX-DR-P-30000
08/24/16
NG
LM
Brent Cross Phase1B (North) RMA
0 2.5m 5m 10m 25m
1 : 250NORTH-SOUTH SECTION - SOUTHERN DEPARTMENT1
1 : 250NORTH-SOUTH SECTION - SOUTHERN DEPARTMENT (RAMP)2
12
REV NO. DATE DESCRIPTIONP1 10/02/17 RMA Draft Issue for CommentP2 06/03/17 RMA Draft 2P3 17/03/17 RMA Draft 3P4 29/03/17 RMA Final IssueSection 1
Section 2
21
2.0 RETAIL & HOTEL PLOTS, BRENT CROSS MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE
144
NB-LG0
NB-UG0
NB-010
NB-020
NB-B10
NB-RF1
Service Yard
BOH
SD UG
SD 01
SD LG
LE 3-02
NB-LG0
NB-UG0
NB-010
NB-020
NB-B10
NB-RF1
Collect by Car
Tempelhof Avenue
MEP
RS 3 02
SD UG
SD 01
SD LG
SD B1
SD CbC
SD B1
NB-LG0
NB-UG0
NB-010
NB-020
NB-B10
NB-RF1
Tempelhof Avenue
Service Yard
SU 0 09
LE 4 02-M
BOH
SD UG
SD 01
LE 3-02
CALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 250
29/0
3/20
17 1
8:55
:23
P4
PLANNING
SOUTHERNDEPARMTENT SECTIONEAST - WEST- CBC
50-14026
08069-CRL-SD-XXX-DR-P-30001
08/24/16
NG
LM
Brent Cross Phase1B (North) RMA
0 2.5m 5m 10m 25m
1 : 250SOUTHERN DEPARTMENT SECTION 011
23
1
1 : 250SECTION - SOUTHERN DEPARTMENT COLLECT BY CAR2 1 : 250
SECTION - SOUTHERN DEPARTMENT TEMPELHOF BRIDGE3
REV NO. DATE DESCRIPTIONP1 10/02/17 RMA Draft Issue for CommentP2 06/03/17 RMA Draft 2P3 17/03/17 RMA Draft 3P4 29/03/17 RMA Final Issue
Sections
NB-LG0
NB-UG0
NB-010
NB-020
NB-B10
NB-RF1
Service Yard
BOH
SD UG
SD 01
SD LG
LE 3-02
NB-LG0
NB-UG0
NB-010
NB-020
NB-B10
NB-RF1
Collect by Car
Tempelhof Avenue
MEP
RS 3 02
SD UG
SD 01
SD LG
SD B1
SD CbC
SD B1
NB-LG0
NB-UG0
NB-010
NB-020
NB-B10
NB-RF1
Tempelhof Avenue
Service Yard
SU 0 09
LE 4 02-M
BOH
SD UG
SD 01
LE 3-02
CALLISONRTKL
25 Farringdon Street, 10th FloorLondon EC4A 4AB
T:+44(0)20 7306 0404
PROJECT
2016 CALLISONRTKL UK Ltd
CLIENT
KEY PLAN
TITLE
STATUS
PROJECT NUMBER
GENERAL NOTES
c
DATE DRAWN:
DRAWN BY:
CHECKED BY:
SCALE @ A1:
All rights reserved.
All drawings and written material appearing here,constitute original and unpublished work of the Architectand may not be duplicated, used or disclosed withoutwritten consent of the Architect.
Notes and material designations are typical for similarconditions unless otherwise indicated.
Colour of materials are indicative only. Colours will be specified later.
Do not scale from this drawing except for town planning purposes.
Please see notes attached at drawing notes Q1.
Where it is a composite drawing of CRTKL + CT, CT buildings areindicated in grey.
SHEET IDENTIFICATION
REVISION
NC
WC
JL
EB
FN
EC
HA
NB
EN
SD
SB
PROJECT ORIGINATOR ZONE LEVEL TYPE ROLE DESCRIPTION
1 : 250
29/0
3/20
17 1
8:55
:23
P4
PLANNING
SOUTHERNDEPARMTENT SECTIONEAST - WEST- CBC
50-14026
08069-CRL-SD-XXX-DR-P-30001
08/24/16
NG
LM
Brent Cross Phase1B (North) RMA
0 2.5m 5m 10m 25m
1 : 250SOUTHERN DEPARTMENT SECTION 011
23
1
1 : 250SECTION - SOUTHERN DEPARTMENT COLLECT BY CAR2 1 : 250
SECTION - SOUTHERN DEPARTMENT TEMPELHOF BRIDGE3
REV NO. DATE DESCRIPTIONP1 10/02/17 RMA Draft Issue for CommentP2 06/03/17 RMA Draft 2P3 17/03/17 RMA Draft 3P4 29/03/17 RMA Final Issue
Section 1
Section 2 Section 3
31
2
2.0 RETAIL & HOTEL PLOTS, BRENT CROSS MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE2.0 RETAIL & HOTEL PLOTS, MAIN SQUARE THRESHOLD SPACES & ENERGY CENTRE
145
top related