Damp investigation

Chelsea FC – leaking shower cubicles, not basement ground water as they thought

Page 3: All Services

www.kemltd.eu

Damp investigation

Water ingress from window only visible to the naked eye at ground level.Client originally perceived problem to be ground level issue.

Page 4: All Services

www.kemltd.eu

Damp investigation

Rain water ingress proven by flourescein tracer dye flood testing. Dye evident in lift shaft.

Page 5: All Services

www.kemltd.eu

Damp investigation

Borescope inspection

Page 6: All Services

www.kemltd.eu

Damp investigation

Damp meters:•Resistance•Capacitance•Relative humidity

Page 7: All Services

www.kemltd.eu

Damp investigation

Salts analysis Water analysis

Page 8: All Services

www.kemltd.eu

Defect investigation

Water ingress through roof covering defect

Page 9: All Services

www.kemltd.eu

Defect investigation

Render delamination

Page 10: All Services

www.kemltd.eu

Defect investigation

Covering bubbling Screed break down

Flooring defects – services include UKAS laboratory sample testing

Page 11: All Services

www.kemltd.eu

Condensation

Thermal bridge from car park below creating condensation risk

Page 12: All Services

www.kemltd.eu

Condensation

Data logger shows dew point circa 20 degrees celcius, bottom of wall below dew point. Mould and damp evident.

Page 13: All Services

www.kemltd.eu

Leak detection

Door bar nail punctured heating pipe

Page 14: All Services

www.kemltd.eu

Leak detection

Poorly fitted radiator joint in floor

Page 15: All Services

www.kemltd.eu

Leak detection

Under floor heating leak

Page 16: All Services

www.kemltd.eu

Leak detection

Acoustic testing

Page 17: All Services

www.kemltd.eu

Insulation Continuity

Insulation removed to repair balcony defect, not reinstated

Page 18: All Services

www.kemltd.eu

Insulation Continuity

Floor slab thermal bridge in A1

Page 19: All Services

www.kemltd.eu

Insulation Continuity

Failure to install insulation in hipped roof

Page 20: All Services

www.kemltd.eu

Insulation Continuity

Missing insulation at eaves and light fitting

Page 21: All Services

www.kemltd.eu

Insulation Continuity

Missing insulation in conference centre bedroom

Page 22: All Services

www.kemltd.eu

Insulation Continuity

Thermal bridge due to air brick for ventilation to flat above

Page 23: All Services

www.kemltd.eu

Energy surveys& certification

EPC – Domestic & social housing

DEC – Public buildings