“Alkylph in the frame of 1. Objectives To check the chemical analysis o European Water Framework Dire 2. Parameters to be an Alkylphenol Nonylp Octylp Bisphenol A 3. Samples characteris 3.1. Sample preparation Concentrated solution diluted in a 3.2. Concentration levels The concentration levels to be different parameters 3.3. Containers One 10 mL glass vial containing a Two 1000 mL glass bottles conta 3.4. Conservation Cooling and darkness during tran 3.5. Number of samples p Each participant receives one sa under repeatability conditions. 3.6. Samples packaging All samples are packed in cardbo compound. 3.7. Samples distribution Samples are sent by the coopera henols and Bisphenol A f the 2012 joint programme of t of these compounds in the context of chemica ective (WFD). nalysed Parameters ls phenol (4-Nonylfenol, C.A.S.=104-40-5) phenol (4-Tert-Octylphenol, C.A.S. = 140-66-9 ) A stics a matrix of water will be used as PT sample. s analyzed in the PT will be between 0.01 a concentrated solution of these specific para aining the matrix water nsport and storage. per participant ample of the batch and the analysis should oard boxes (1 per lab) including one double n ating partner (CP) to the corresponding partic 1/4 A” the PT-WFD al monitoring for the and 2 μg.L -1 for the ameters be made by triplicate polystyrene moulding cipants.

Upload: others

Post on 04-Jun-2022

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: “Alkylphenols and Bisphenol A”

“Alkylphenols and Bisphenol A”

in the frame of the 2012 joint programme of the PT

1. Objectives To check the chemical analysis of these compounds in the context ofEuropean Water Framework Directive (WFD).

2. Parameters to be analysed

Alkylphenols

Nonylphenol

Octylphenol

Bisphenol A

3. Samples characteristics

3.1. Sample preparationConcentrated solution diluted in a matrix

3.2. Concentration levelsThe concentration levels to be analyzdifferent parameters

3.3. Containers One 10 mL glass vial containing a concentrated solution of these specific Two 1000 mL glass bottles containing the matrix water

3.4. Conservation Cooling and darkness during transport and storage.

3.5. Number of samples per participantEach participant receives one sample under repeatability conditions.

3.6. Samples packaging All samples are packed in cardboard boxes (1 per lab) including one double polystyrene compound.

3.7. Samples distributionSamples are sent by the cooperating

“Alkylphenols and Bisphenol A”n the frame of the 2012 joint programme of the PT

To check the chemical analysis of these compounds in the context of chemical monitoring for the European Water Framework Directive (WFD).

Parameters to be analysed

Parameters

Alkylphenols

lphenol (4-Nonylfenol, C.A.S.=104-40-5)

ctylphenol (4-Tert-Octylphenol, C.A.S. = 140-66-9 )

Bisphenol A

characteristics

Concentrated solution diluted in a matrix of water will be used as PT sample.

Concentration levels oncentration levels to be analyzed in the PT will be between 0.01

a concentrated solution of these specific parameterscontaining the matrix water

during transport and storage.

per participant one sample of the batch and the analysis should be made by triplicate

All samples are packed in cardboard boxes (1 per lab) including one double polystyrene

Samples distribution Samples are sent by the cooperating partner (CP) to the corresponding participants.

1/4

“Alkylphenols and Bisphenol A” n the frame of the 2012 joint programme of the PT-WFD

chemical monitoring for the

and 2 µg.L-1 for the

parameters

and the analysis should be made by triplicate

All samples are packed in cardboard boxes (1 per lab) including one double polystyrene moulding

the corresponding participants.

Page 2: “Alkylphenols and Bisphenol A”

4. Application procedureThe registration can be made directly though the form.

5. Confidentiality To ensure the confidentiality, a secret code number is

6. Execution of the analysisThe samples must be analyzed in the own laboratory with own personnel and own equipmentfollowing their internal procedures

7. Data transfer Participants shall report results through the corresponding CP using the appropriate form.

8. Data Evaluation 8.1. Assigned values

The statistical evaluation of the PT will be done by according to ISO 13528 for calculation of the mean. provide traceable assigned values, with allowance for matrix contributions, and this will be the source of the assigned value. The standard uncertainty of the assigned value derived according to internationally recognized standards or guidelines.

8.2. Standard deviation for proficiency assessment (SDPA)It is calculated in compliance with the requirements

8.3. Assessment For each measurement value x, a zaccording to following formula:

The assessment of the results will be

|z-score| ≤ 2.0 2.0 < |z-score| < 3.0 |z-score| ≥ 3.0

9. Reporting

The report will be prepared by ielabCP.

Application procedure The registration can be made directly though the CP sending the application

To ensure the confidentiality, a secret code number is provided by the CP.

Execution of the analysis ed in the own laboratory with own personnel and own equipment

following their internal procedures. Subcontracting of the analysis is not allowed.

through the corresponding CP using the appropriate form.

The statistical evaluation of the PT will be done by ielab. It will be carried out using Algorithm A ISO 13528 for calculation of the mean. The preparation process of the samples can

provide traceable assigned values, with allowance for matrix contributions, and this will be the d value. The standard uncertainty of the assigned value

derived according to internationally recognized standards or guidelines.

Standard deviation for proficiency assessment (SDPA) is calculated in compliance with the requirements of the PT-WFD network: SDPA = 0.25 * X.

For each measurement value x, a z-score will be calculated from the assigned value X and SDPA

z= (x-X)/SPDA

will be as follows:

Satisfactory result Questionable result

Unsatisfactory result

ielab and distributed to the final participants by the corresponding

2/4

CP sending the application

ed in the own laboratory with own personnel and own equipment Subcontracting of the analysis is not allowed.

through the corresponding CP using the appropriate form.

. It will be carried out using Algorithm A The preparation process of the samples can

provide traceable assigned values, with allowance for matrix contributions, and this will be the d value. The standard uncertainty of the assigned value will be estimated or

WFD network: SDPA = 0.25 * X.

calculated from the assigned value X and SDPA

cipants by the corresponding

Page 3: “Alkylphenols and Bisphenol A”

10. Time schedule

1. Registration deadline: May 12. Dispatch of the samples: May 73. Deadline for results: June 8

11. Participation fee

The participation fee will be € 35costs, please contact your PT provider.

12. Organizers ielab is in charge of the central organisation and is going to perform the statistical evaluation.

ielab Calidad, S.L.U

C/ Dracma, 16Polígono Industrial Las Atalayas03114 AlicanteSPAIN

This PT is accomplished in cooperation with the following organisations of the “PT

BSG HU, Hamburg

Marckmannstr. 129 b

D-20539 HamburgGERMANY

BIPEA

6 à 14 avenue Louis Roche

92230 Gennevilliers

FRANCE

LGC Standards

1 Chamberhall Business Park

Chamberhall Green

Bury Lancashire BL9 0AP

United Kingdom

QUALITYCONSULT

"Associazione per lo sviluppo della

qualità ambientale"

Via G. Bettolo 4

00195 Roma

ITALY

deadline: May 1st, 2012 Dispatch of the samples: May 7th, 2012 Deadline for results: June 8th, 2012

50 plus VAT, where applicable, and transport costs.costs, please contact your PT provider.

is in charge of the central organisation and is going to perform the statistical evaluation.

ielab Calidad, S.L.U

C/ Dracma, 16 Polígono Industrial Las Atalayas 03114 Alicante

Tel: +34 966 10 55 01

Fax: +34 966 10 55 03

[email protected]

This PT is accomplished in cooperation with the following organisations of the “PT

Hamburg

Marckmannstr. 129 b

20539 Hamburg GERMANY

Tel: +49 40 42845-3645

Fax: +49 40 42845-3847

[email protected]

6 à 14 avenue Louis Roche

92230 Gennevilliers

Tel: +33 (0) 1 47 33 54 60

Fax: +33 (0) 1 40 86 92 59

[email protected]

LGC Standards - Proficiency Testing

1 Chamberhall Business Park

Chamberhall Green

Bury Lancashire BL9 0AP

United Kingdom

Tel: +44 (0) 161 762 2500

Fax: +44 (0) 161 762 2501

[email protected]

QUALITYCONSULT

"Associazione per lo sviluppo della

qualità ambientale"

Via G. Bettolo 4

00195 Roma

Tel: +39 320-6905464

Fax: +39 0697840718

[email protected]

3/4

transport costs. For transport

is in charge of the central organisation and is going to perform the statistical evaluation.

This PT is accomplished in cooperation with the following organisations of the “PT-WFD” network:

[email protected]

Page 4: “Alkylphenols and Bisphenol A”

Proftest, SYKE Finnish Environment

Institute

Hakuninmaantie

FIN-00251 Helsinki

FINLAND

A.G.L.A.E.

427 rue des Bourreliers

Parc des Pyramides

59320 Hallennes lez Haubourdin

FRANCE

Proftest, SYKE Finnish Environment

Hakuninmaantie

00251 Helsinki

Tel: +358 20 610 123

Fax: +358 9 448 320

[email protected]

427 rue des Bourreliers

Parc des Pyramides - bât D

59320 Hallennes lez Haubourdin

Tel: +33 (0)3 20 16 91 40

Fax: +33 (0)3 20 16 91 41

[email protected]

4/4

aglae.fr