เฟ้ลปส์ ดอด์จ ที่ ... - phelps dodge cable · bangplee factory...
TRANSCRIPT
เฟลปส ดอดจ ทหนงดานเทคโนโลยสายโทรศพท
Bangplee Factory located in Samutprakarn province is the only wire & cable manufacturer in Thailand that supply high voltage and extra high voltage XLPE POWER CABLE upto 245 kv and having complete in-house facilities for testing power cable upto 400kV
Contents
PAGENO.
PRODUCTCODE STANDARD CABLE NAME APPLICATIONTELEPHONE AND
COMMUNICATION CABLE
ELECTRICAL CHARACTERISTICS
AL-PE SheathedCable
Superior-quality aerial telephone cableparticularly designed for exchange areatelephone distribution lines
04 AP TOT/TIS2434-2552
AL-PE SheathedCable With SteelWire Armour
13 AP-SWA TOT
Double SheathedAlpeth Cable10 PAP TOT
Fig. 8 AL-PESheathed Cable07 AP(8)
TOT/TIS2434-2552
Interior Cable25 IN TOT
29
Station Wire28 ST TOT
Figure 8Unshielded TwistedPair Drop Wire
24 UTP DW(8) TOT
Self-supportedDrop Wire23 SS-DP TOT
Foam-skin InsulationAL-PE SheathedFilled Cable WithSteel Tape Armour
19 ASP-FSF TOT
Foam-skin InsulationAL-PE Sheathed,Filled Cable,With S-Screen
22 DSAP-FSF TOT
Foam-skin InsulationAL-PE SheathedFilled Cable
16 AP-FSF TOT
Specially designed telephone cables withgalvanized steel wires as an armour fordirect burial installation in exchangearea telephone distribution lines
Specially designed telephone cables withhigh-quality double sheaths for directburial installation in exchange areatelephone distribution lines
Superior-quality aerial telephone cablewith self-supporting messengerparticularly designed for exchange areatelephone distribution lines
Superior-quality indoor telephone cablefor connecting subscriber equipmentinside the building
Superior-quality indoor telephone wirefor general use inside a telephonesubscriber station
Superior-quality aerial telephone cablefor extending from cable terminal toa building
Superior-quality aerial telephone cablefor distribution service servinghigh-speed data communication
Specially designed undergroundtelephone cable with steel tape armourand special compounds filled to protectmoisture and ensure longest lifetime,suitable for exchange area andtrunk services
Specially designed undergroundtelephone cable for high frequencytransmission
Superior-quality underground telephonecable with special compounds filled toprotect moisture and ensure longestlifetime, suitable for exchange areaand trunk services
Contents
PAGENO.
PRODUCTCODE STANDARD CABLE NAME APPLICATIONTELEPHONE AND
COMMUNICATION CABLE
ELECTRICAL CHARACTERISTICS
AL-PE SheathedCable
Superior-quality aerial telephone cableparticularly designed for exchange areatelephone distribution lines
04 AP TOT/TIS2434-2552
AL-PE SheathedCable With SteelWire Armour
13 AP-SWA TOT
Double SheathedAlpeth Cable10 PAP TOT
Fig. 8 AL-PESheathed Cable07 AP(8)
TOT/TIS2434-2552
Interior Cable25 IN TOT
29
Station Wire28 ST TOT
Figure 8Unshielded TwistedPair Drop Wire
24 UTP DW(8) TOT
Self-supportedDrop Wire23 SS-DP TOT
Foam-skin InsulationAL-PE SheathedFilled Cable WithSteel Tape Armour
19 ASP-FSF TOT
Foam-skin InsulationAL-PE Sheathed,Filled Cable,With S-Screen
22 DSAP-FSF TOT
Foam-skin InsulationAL-PE SheathedFilled Cable
16 AP-FSF TOT
Specially designed telephone cables withgalvanized steel wires as an armour fordirect burial installation in exchangearea telephone distribution lines
Specially designed telephone cables withhigh-quality double sheaths for directburial installation in exchange areatelephone distribution lines
Superior-quality aerial telephone cablewith self-supporting messengerparticularly designed for exchange areatelephone distribution lines
Superior-quality indoor telephone cablefor connecting subscriber equipmentinside the building
Superior-quality indoor telephone wirefor general use inside a telephonesubscriber station
Superior-quality aerial telephone cablefor extending from cable terminal toa building
Superior-quality aerial telephone cablefor distribution service servinghigh-speed data communication
Specially designed undergroundtelephone cable with steel tape armourand special compounds filled to protectmoisture and ensure longest lifetime,suitable for exchange area andtrunk services
Specially designed undergroundtelephone cable for high frequencytransmission
Superior-quality underground telephonecable with special compounds filled toprotect moisture and ensure longestlifetime, suitable for exchange areaand trunk services
06
09
12
15
18
21
24
25
26
27
30
31
TOT/PDITL
TOT/PDITL
TOT/PDITL
TOT/PDITL
TOT/PDITL
TOT/PDITL
TOT/PDITL
TOT/PDITL
TOT/PDITL
4 TELECOMMUNICATION CABLES
AP : AL-PE SHEATHED CABLE
For exchange area telephone distribution lines, principally for aerial installation by attachment to a support strand. It may be used, however, in underground ducts where there is no damage due to mechanical abuse.
APPLICATION :
no water in ducts and underground.and
STANDARD :
TIS 2434-2552 / TOT
TIS 2434-2552
6
4 TELECOMMUNICATION CABLES
AP : AL-PE SHEATHED CABLE
For exchange area telephone distribution lines, principally for aerial installation by attachment to a support strand. It may be used, however, in underground ducts where there is no damage due to mechanical abuse.
APPLICATION :
5TELECOMMUNICATION CABLES
Conductor(mm)
Number of pairs Product code
Nominal insulation thickness
(mm)
Nominal sheath
thickness(mm)
Approximateoverall
diameter(mm)
Approximate cable weight
(kg/km)
Standard length
(m)
0.4 5 26 AP 005 0.15 1.5 8.5 60 1,000/R6 26 AP 006 0.15 1.5 9.0 65 1,000/R
10 26 AP 010 0.15 1.5 9.5 80 1,000/R12 26 AP 012 0.15 1.5 10.0 90 1,000/R15 26 AP 015 0.15 1.5 10.5 100 1,000/R20 26 AP 020 0.15 1.5 11.0 120 1,000/R25 26 AP 025 0.15 1.5 12.0 140 1,000/R30 26 AP 030 0.15 1.5 12.5 155 1,000/R40 26 AP 040 0.15 1.5 13.5 190 1,000/R50 26 AP 050 0.15 1.5 14.5 220 1,000/R75 26 AP 075 0.15 1.5 16.5 300 1,000/R
100 26 AP 100 0.15 1.5 18.0 380 1,000/R150 26 AP 150 0.15 1.5 21.0 540 500/R200 26 AP 200 0.15 1.5 24.0 690 500/R300 26 AP 300 0.15 1.5 27.5 1,000 500/R400 26 AP 400 0.15 1.8 31.5 1,300 500/R600 26 AP 600 0.15 2.0 37.5 1,900 500/R900 26 AP 900 0.15 2.3 45.5 2,800 250/R
0.5 5 24 AP 005 0.20 1.5 9.5 70 1,000/R6 24 AP 006 0.20 1.5 10.0 75 1,000/R
10 24 AP 010 0.20 1.5 11.0 100 1,000/R12 24 AP 012 0.20 1.5 11.5 120 1,000/R15 24 AP 015 0.20 1.5 12.0 130 1,000/R20 24 AP 020 0.20 1.5 13.0 160 1,000/R25 24 AP 025 0.20 1.5 14.0 190 1,000/R30 24 AP 030 0.20 1.5 14.5 220 1,000/R40 24 AP 040 0.20 1.5 16.0 270 1,000/R50 24 AP 050 0.20 1.5 17.0 320 1,000/R75 24 AP 075 0.20 1.5 19.5 440 1,000/R
100 24 AP 100 0.20 1.5 22.5 570 1,000/R150 24 AP 150 0.20 1.5 26.0 810 500/R200 24 AP 200 0.20 1.8 29.5 1,070 500/R300 24 AP 300 0.20 1.8 35.0 1,530 500/R400 24 AP 400 0.20 2.0 39.5 2,010 500/R600 24 AP 600 0.20 2.3 48.0 2,980 350/R900 24 AP 900 0.20 2.5 57.0 4,415 250/R
R = Packing in reel
AP : AL-PE SHEATHED CABLE
7
6 TELECOMMUNICATION CABLES
R = Packing in reel
Conductor(mm)
Number of pairs
Product code
Nominal insulation thickness
(mm)
Nominal sheath
thickness(mm)
Approximate overall
diameter(mm)
Approximate cable weight
(kg/km)
Standard length
(m)
0.65 5 22 AP 005 0.25 1.5 10.5 90 1,000/R6 22 AP 006 0.25 1.5 11.0 100 1,000/R
10 22 AP 010 0.25 1.5 12.5 130 1,000/R12 22 AP 012 0.25 1.5 13.0 160 1,000/R15 22 AP 015 0.25 1.5 13.5 180 1,000/R20 22 AP 020 0.25 1.5 15.0 230 1,000/R25 22 AP 025 0.25 1.5 16.0 260 1,000/R30 22 AP 030 0.25 1.5 17.0 310 1,000/R40 22 AP 040 0.25 1.5 19.0 390 1,000/R50 22 AP 050 0.25 1.5 20.5 460 1,000/R75 22 AP 075 0.25 1.5 24.0 660 1,000/R
100 22 AP 100 0.25 1.5 27.0 850 500/R150 22 AP 150 0.25 1.8 32.0 1,240 500/R200 22 AP 200 0.25 2.0 36.5 1,630 500/R300 22 AP 300 0.25 2.0 43.5 2,380 350/R400 22 AP 400 0.25 2.3 50.0 3,120 250/R600 22 AP 600 0.25 2.5 59.5 4,610 250/R
0.9 5 19 AP 005 0.30 1.5 12.5 140 1,000/R6 19 AP 006 0.30 1.5 13.0 160 1,000/R
10 19 AP 010 0.30 1.5 15.0 220 1,000/R12 19 AP 012 0.30 1.5 16.0 260 1,000/R15 19 AP 015 0.30 1.5 17.5 310 1,000/R20 19 AP 020 0.30 1.5 19.0 390 1,000/R25 19 AP 025 0.30 1.5 20.5 460 1,000/R30 19 AP 030 0.30 1.5 22.5 570 1,000/R40 19 AP 040 0.30 1.5 25.5 720 1,000/R50 19 AP 050 0.30 1.5 27.5 850 500/R75 19 AP 075 0.30 1.8 33.0 1,240 500/R
100 19 AP 100 0.30 2.0 37.0 1,620 500/R150 19 AP 150 0.30 2.0 44.5 2,380 500/R200 19 AP 200 0.30 2.3 51.0 3,130 500/R300 19 AP 300 0.30 2.5 60.5 4,700 250/R400 19 AP 400 0.30 2.8 69.5 6,210 250/R
AP : AL-PE SHEATHED CABLE
8
7TELECOMMUNICATION CABLES
AP(8) : FIGURE 8 AL-PE SHEATHED CABLE
For exchange area telephone distribution lines, it is designed, especially for aerial installation by using the support messenger.
APPLICATION :
STANDARD :
TIS 2434-2552 / TOT
TIS 2434-2552
9
8 TELECOMMUNICATION CABLES
R = Packing in reel
Conductor(mm)
Number of pairs
Product code
Support messenger
wirediameter
(mm)
Nominal sheath thickness
(mm)
Approximate overall diameter
(mm)Approximate cable weight
(kg/km)
Standard length
(m)Support messenger
Cable core
d D H
0.4 5 26 AP (8) 005 2.03 1.5 1.5 9.1 8.5 20.5 250 1,000/R6 26 AP (8) 006 2.03 1.5 1.5 9.1 9.0 21.0 260 1,000/R
10 26 AP (8) 010 2.03 1.5 1.5 9.1 9.5 21.5 270 1,000/R12 26 AP (8) 012 2.03 1.5 1.5 9.1 10.0 22.0 280 1,000/R15 26 AP (8) 015 2.03 1.5 1.5 9.1 10.5 22.5 290 1,000/R20 26 AP (8) 020 2.03 1.5 1.5 9.1 11.0 23.5 310 1,000/R25 26 AP (8) 025 2.03 1.5 1.5 9.1 12.0 24.0 330 1,000/R30 26 AP (8) 030 2.03 1.5 1.5 9.1 12.5 24.5 350 1,000/R40 26 AP (8) 040 2.03 1.5 1.5 9.1 13.5 25.5 390 1,000/R50 26 AP (8) 050 2.03 1.5 1.5 9.1 14.5 26.5 410 1,000/R75 26 AP (8) 075 2.03 1.5 1.5 9.1 16.5 28.5 490 1,000/R
100 26 AP (8) 100 2.03 1.5 1.5 9.1 18.0 30.0 570 1,000/R150 26 AP (8) 150 2.03 1.5 1.5 9.1 21.0 33.0 730 1,000/R200 26 AP (8) 200 2.03 1.5 1.5 9.1 23.5 36.0 880 500/R300 26 AP (8) 300 2.03 1.5 1.5 9.1 27.5 39.5 1,220 500/R400 26 AP (8) 400 2.03 1.8 1.8 9.7 31.5 44.0 1,490 500/R
0.5 5 24 AP (8) 005 2.03 1.5 1.5 9.1 9.5 21.5 260 1,000/R6 24 AP (8) 006 2.03 1.5 1.5 9.1 9.5 22.0 265 1,000/R
10 24 AP (8) 010 2.03 1.5 1.5 9.1 11.0 23.0 290 1,000/R12 24 AP (8) 012 2.03 1.5 1.5 9.1 11.5 23.5 310 1,000/R15 24 AP (8) 015 2.03 1.5 1.5 9.1 12.0 24.0 330 1,000/R20 24 AP (8) 020 2.03 1.5 1.5 9.1 13.0 25.0 350 1,000/R25 24 AP (8) 025 2.03 1.5 1.5 9.1 14.0 26.0 380 1,000/R30 24 AP (8) 030 2.03 1.5 1.5 9.1 14.5 26.5 420 1,000/R40 24 AP (8) 040 2.03 1.5 1.5 9.1 16.0 28.0 470 1,000/R50 24 AP (8) 050 2.03 1.5 1.5 9.1 17.0 29.0 510 1,000/R75 24 AP (8) 075 2.03 1.5 1.5 9.1 19.5 31.5 630 1,000/R
100 24 AP (8) 100 2.03 1.5 1.5 9.1 22.5 34.5 760 1,000/R150 24 AP (8) 150 2.03 1.5 1.5 9.1 26.0 38.0 1,000 500/R200 24 AP (8) 200 2.03 1.8 1.8 9.7 29.5 42.5 1,260 500/R300 24 AP (8) 300 2.03 1.8 1.8 9.7 34.5 47.5 1,720 350/R
AP(8) : FIGURE 8 AL-PE SHEATHED CABLE
10
9TELECOMMUNICATION CABLES
R = Packing in reel
Conductor(mm)
Number of pairs
Product code
Support messenger
wire diameter(mm)
Nominal sheath thickness
(mm)
Approximate overall diameter
(mm)Approximate cable weight
(kg/km)
Standard length
(m)Support messenger
Cable core
d D H
0.65 5 22 AP (8) 005 2.03 1.5 1.5 9.1 10.5 22.5 280 1,000/R6 22 AP (8) 006 2.03 1.5 1.5 9.1 11.0 23.0 290 1,000/R
10 22 AP (8) 010 2.03 1.5 1.5 9.1 12.5 24.5 320 1,000/R12 22 AP (8) 012 2.03 1.5 1.5 9.1 13.0 25.0 350 1,000/R15 22 AP (8) 015 2.03 1.5 1.5 9.1 13.5 26.0 380 1,000/R20 22 AP (8) 020 2.03 1.5 1.5 9.1 15.0 27.0 420 1,000/R25 22 AP (8) 025 2.03 1.5 1.5 9.1 16.0 28.0 450 1,000/R30 22 AP (8) 030 2.03 1.5 1.5 9.1 17.0 29.0 510 1,000/R40 22 AP (8) 040 2.03 1.5 1.5 9.1 19.0 31.0 590 1,000/R50 22 AP (8) 050 2.03 1.5 1.5 9.1 20.5 32.5 650 1,000/R75 22 AP (8) 075 2.03 1.5 1.5 9.1 24.0 36.5 850 500/R
100 22 AP (8) 100 2.03 1.5 1.5 9.1 27.0 39.0 1,040 500/R150 22 AP (8) 150 2.03 1.8 1.8 9.7 32.0 45.0 1,430 500/R200 22 AP (8) 200 2.03 2.0 2.0 10.1 36.5 49.5 1,820 350/R300 22 AP (8) 300 2.03 2.0 2.0 10.1 43.5 56.5 2,570 250/R
0.9 5 19 AP (8) 005 2.03 1.5 1.5 9.1 12.5 24.5 330 1,000/R6 19 AP (8) 006 2.03 1.5 1.5 9.1 13.0 25.0 350 1,000/R
10 19 AP (8) 010 2.03 1.5 1.5 9.1 15.0 27.5 410 1,000/R12 19 AP (8) 012 2.03 1.5 1.5 9.1 16.0 28.0 450 1,000/R15 19 AP (8) 015 2.03 1.5 1.5 9.1 17.5 29.5 500 1,000/R20 19 AP (8) 020 2.03 1.5 1.5 9.1 19.0 31.0 580 1,000/R25 19 AP (8) 025 2.03 1.5 1.5 9.1 20.5 33.0 650 1,000/R30 19 AP (8) 030 2.03 1.5 1.5 9.1 22.5 35.0 770 1,000/R40 19 AP (8) 040 2.03 1.5 1.5 9.1 25.5 37.5 920 1,000/R50 19 AP (8) 050 2.03 1.5 1.5 9.1 27.5 39.5 1,040 500/R75 19 AP (8) 075 2.03 1.8 1.8 9.7 33.0 45.5 1,430 500/R
100 19 AP (8) 100 2.03 2.0 2.0 10.1 37.0 50.5 1,810 350/R150 19 AP (8) 150 2.03 2.0 2.0 10.1 44.5 57.5 2,570 250/R200 19 AP (8) 200 2.03 2.3 2.3 10.7 51.0 64.5 3,440 250/R
AP(8) : FIGURE 8 AL-PE SHEATHED CABLE
11
10 TELECOMMUNICATION CABLES
PAP : DOUBLE SHEATHED ALPETH CABLE
For exchange area telephone distribution lines, It is designed for direct burial in ground where there is no damage due to mechanical abuse.
APPLICATION :
and no water in underground.
STANDARD :
TOT/PDITL
12
11TELECOMMUNICATION CABLES
PAP : DOUBLE SHEATHED ALPETH CABLE
Conductor(mm)
Number of pairs
Productcode
Nominal insulation thickness
(mm)
Nominal sheath thickness
(mm)Approximate overall
diameter(mm)
Approximate cable weight
(kg/km)
Standard length
(m)Inner Outer0.4 5 26 PAP 005 0.15 1.2 1.5 11.0 85 1,000/R
6 26 PAP 006 0.15 1.2 1.5 11.0 90 1,000/R10 26 PAP 010 0.15 1.2 1.5 12.0 110 1,000/R12 26 PAP 012 0.15 1.2 1.5 12.5 120 1,000/R15 26 PAP 015 0.15 1.2 1.5 13.0 140 1,000/R20 26 PAP 020 0.15 1.2 1.5 13.5 150 1,000/R25 26 PAP 025 0.15 1.2 1.5 14.5 175 1,000/R30 26 PAP 030 0.15 1.2 1.5 15.0 195 1,000/R40 26 PAP 040 0.15 1.2 1.5 16.0 235 1,000/R50 26 PAP 050 0.15 1.2 1.5 17.0 270 1,000/R75 26 PAP 075 0.15 1.2 1.5 19.0 360 1,000/R
100 26 PAP 100 0.15 1.2 1.5 20.5 445 1,000/R150 26 PAP 150 0.15 1.2 1.5 23.0 610 500/R200 26 PAP 200 0.15 1.2 1.5 26.0 770 500/R300 26 PAP 300 0.15 1.2 1.5 30.0 1,135 500/R400 26 PAP 400 0.15 1.6 1.8 34.5 1,455 500/R600 26 PAP 600 0.15 1.6 2.0 40.5 2,100 500/R900 26 PAP 900 0.15 1.6 2.0 48.0 3,070 250/R
0.5 5 24 PAP 005 0.20 1.2 1.5 11.5 100 1,000/R6 24 PAP 006 0.20 1.2 1.5 12.0 110 1,000/R
10 24 PAP 010 0.20 1.2 1.5 13.0 140 1,000/R12 24 PAP 012 0.20 1.2 1.5 13.5 150 1,000/R15 24 PAP 015 0.20 1.2 1.5 14.5 170 1,000/R20 24 PAP 020 0.20 1.2 1.5 15.5 200 1,000/R25 24 PAP 025 0.20 1.2 1.5 16.0 230 1,000/R30 24 PAP 030 0.20 1.2 1.5 17.0 265 1,000/R40 24 PAP 040 0.20 1.2 1.5 18.5 320 1,000/R50 24 PAP 050 0.20 1.2 1.5 19.5 370 1,000/R75 24 PAP 075 0.20 1.2 1.5 22.0 505 1,000/R
100 24 PAP 100 0.20 1.2 1.5 25.0 640 1,000/R150 24 PAP 150 0.20 1.2 1.5 28.5 890 500/R200 24 PAP 200 0.20 1.6 1.8 33.0 1,190 500/R300 24 PAP 300 0.20 1.6 1.8 38.0 1,700 500/R400 24 PAP 400 0.20 1.6 2.0 42.5 2,200 500/R600 24 PAP 600 0.20 1.8 2.3 51.5 3,235 250/R900 24 PAP 900 0.20 2.0 2.5 61.0 4,705 250/R
R = Packing in reel
13
12 TELECOMMUNICATION CABLES
Conductor(mm)
Number of pairs
Productcode
Nominal insulation thickness
(mm)
Nominal sheath thickness
(mm)Approximate overall
diameter(mm)
Approximate cable weight
(kg/km)
Standard length
(m)Inner Outer0.65 5 22 PAP 005 0.25 1.2 1.5 13.0 120 1,000/R
6 22 PAP 006 0.25 1.2 1.5 13.0 135 1,000/R10 22 PAP 010 0.25 1.2 1.5 14.5 175 1,000/R12 22 PAP 012 0.25 1.2 1.5 15.5 195 1,000/R15 22 PAP 015 0.25 1.2 1.5 16.0 230 1,000/R20 22 PAP 020 0.25 1.2 1.5 17.5 270 1,000/R25 22 PAP 025 0.25 1.2 1.5 18.5 315 1,000/R30 22 PAP 030 0.25 1.2 1.5 19.5 365 1,000/R40 22 PAP 040 0.25 1.2 1.5 21.0 450 1,000/R50 22 PAP 050 0.25 1.2 1.5 22.5 530 500/R75 22 PAP 075 0.25 1.2 1.5 26.5 730 500/R
100 22 PAP 100 0.25 1.2 1.5 29.5 930 500/R150 22 PAP 150 0.25 1.6 1.8 35.5 1,370 500/R200 22 PAP 200 0.25 1.6 2.0 39.5 1,775 500/R300 22 PAP 300 0.25 1.6 2.0 47.0 2,555 250/R400 22 PAP 400 0.25 1.8 2.3 53.5 3,375 250/R600 22 PAP 600 0.25 2.0 2.5 63.5 4,930 250/R
0.9 5 19 PAP 005 0.30 1.2 1.5 15.0 175 1,000/R6 19 PAP 006 0.30 1.2 1.5 15.5 195 1,000/R
10 19 PAP 010 0.30 1.2 1.5 17.5 265 1,000/R12 19 PAP 012 0.30 1.2 1.5 18.5 300 1,000/R15 19 PAP 015 0.30 1.2 1.5 19.5 370 1,000/R20 19 PAP 020 0.30 1.2 1.5 21.5 450 1,000/R25 19 PAP 025 0.30 1.2 1.5 23.0 525 1,000/R30 19 PAP 030 0.30 1.2 1.5 25.0 635 1,000/R40 19 PAP 040 0.30 1.2 1.5 27.5 800 1,000/R50 19 PAP 050 0.30 1.2 1.5 30.0 920 500/R75 19 PAP 075 0.30 1.6 1.8 36.0 1,360 500/R
100 19 PAP 100 0.30 1.6 2.0 40.5 1,765 500/R150 19 PAP 150 0.30 1.6 2.0 48.0 2,545 500/R200 19 PAP 200 0.30 1.8 2.3 54.5 3,440 350/R300 19 PAP 300 0.30 2.0 2.5 64.5 5,010 250/R400 19 PAP 400 0.30 2.0 2.8 73.5 6,560 250/R
R = Packing in reel
PAP : DOUBLE SHEATHED ALPETH CABLE
14
13TELECOMMUNICATION CABLES
AP-SWA : AL-PE SHEATHED CABLE WITH STEEL WIRE ARMOUR
For exchange area telephone distribution lines, in areas of low security such as in canals; across bridges or directly burial in ground where mechanical conditions are not severe.
APPLICATION :
STANDARD :
TOT/PDITL
15
14 TELECOMMUNICATION CABLES
Conductor(mm)
Number of pairs Product code
Nominal insulation thickness
(mm)
Nominal inner sheath
thickness(mm)
Nominal diameter of
armour wires(mm)
Nominal outer sheath
thickness(mm)
Approximate overall
diameter(mm)
Approximate cable weight
(kg/km)
Standard length
(m)
0.4 5 26 AP-SWA 005 0.15 1.5 0.8 1.5 15 260 500/R10 26 AP-SWA 010 0.15 1.5 0.8 1.5 16 305 500/R15 26 AP-SWA 015 0.15 1.5 0.8 1.5 17 380 500/R20 26 AP-SWA 020 0.15 1.5 0.8 1.5 18 410 500/R25 26 AP-SWA 025 0.15 1.5 0.8 1.5 19 440 500/R30 26 AP-SWA 030 0.15 1.5 0.8 1.5 19 470 500/R40 26 AP-SWA 040 0.15 1.5 0.8 1.5 20 520 500/R50 26 AP-SWA 050 0.15 1.5 0.8 1.5 21 570 500/R
100 26 AP-SWA 100 0.15 1.5 1.6 1.5 26 1,100 500/R
0.5 5 24 AP-SWA 005 0.20 1.5 0.8 1.5 16 290 500/R10 24 AP-SWA 010 0.20 1.5 0.8 1.5 18 380 500/R15 24 AP-SWA 015 0.20 1.5 0.8 1.5 19 440 500/R20 24 AP-SWA 020 0.20 1.5 0.8 1.5 20 480 500/R25 24 AP-SWA 025 0.20 1.5 0.8 1.5 21 550 500/R30 24 AP-SWA 030 0.20 1.5 0.8 1.5 21 570 500/R40 24 AP-SWA 040 0.20 1.5 1.6 1.5 24 930 500/R50 24 AP-SWA 050 0.20 1.5 1.6 1.5 25 1,030 500/R
100 24 AP-SWA 100 0.20 1.5 1.6 1.5 30 1,500 500/R
R = Packing in reel
AP-SWA : AL-PE SHEATHED CABLE WITH STEEL WIRE ARMOUR
16
15TELECOMMUNICATION CABLES
Conductor(mm)
Number of pairs Product code
Nominal insulation thickness
(mm)
Nominal inner sheath
thickness(mm)
Nominal diameter of
armour wires(mm)
Nominal outer sheath
thickness(mm)
Approximate overall
diameter(mm)
Approximate cable weight
(kg/km)
Standard length
(m)
0.65 5 22 AP-SWA 005 0.25 1.5 0.8 1.5 17 380 500/R10 22 AP-SWA 010 0.25 1.5 0.8 1.5 19 450 500/R15 22 AP-SWA 015 0.25 1.5 0.8 1.5 21 540 500/R20 22 AP-SWA 020 0.25 1.5 0.8 1.5 22 580 500/R25 22 AP-SWA 025 0.25 1.5 1.6 1.5 24 940 500/R30 22 AP-SWA 030 0.25 1.5 1.6 1.5 25 1,000 500/R40 22 AP-SWA 040 0.25 1.5 1.6 1.5 27 1,160 500/R50 22 AP-SWA 050 0.25 1.5 1.6 1.5 28 1,300 500/R
100 22 AP-SWA 100 0.25 1.5 2.0 1.5 36 2,210 500/R
0.9 5 19 AP-SWA 005 0.30 1.5 0.8 1.5 19 440 500/R10 19 AP-SWA 010 0.30 1.5 0.8 1.5 22 600 500/R15 19 AP-SWA 015 0.30 1.5 1.6 1.5 25 1,020 500/R20 19 AP-SWA 020 0.30 1.5 1.6 1.5 27 1,160 500/R25 19 AP-SWA 025 0.30 1.5 1.6 1.5 28 1,330 500/R30 19 AP-SWA 030 0.30 1.5 1.6 1.5 30 1,520 500/R40 19 AP-SWA 040 0.30 1.5 2.0 1.5 34 2,010 500/R50 19 AP-SWA 050 0.30 1.5 2.0 1.5 36 2,250 500/R
100 19 AP-SWA 100 0.30 2.0 2.5 2.0 48 3,960 500/R
R = Packing in reel
AP-SWA : AL-PE SHEATHED CABLE WITH STEEL WIRE ARMOUR
17
16 TELECOMMUNICATION CABLES
AP-FSF : FOAM-SKIN INSULATION AL-PE SHEATHED FILLED CABLE
The cable is designed for underground (duct) or lashed to an aerial suspension strand in either exchange area service or trunk service.
APPLICATION :
STANDARD :
TOT/PDITL
18
17TELECOMMUNICATION CABLES
AP-FSF : FOAM-SKIN INSULATION AL-PE SHEATHED FILLED CABLE
Conductor(mm)
Number of pairs Product code
Nominal sheath
thickness(mm)
Approximate overall
diameter(mm)
Approximate cable weight
(kg/km)
Standard length
(m)
0.4 25 26 AP-FSF 025 1.5 12.5 170 1,000/R50 26 AP-FSF 050 1.5 16.0 280 1,000/R
100 26 AP-FSF 100 1.5 20.0 470 1,000/R200 26 AP-FSF 200 1.5 25.0 850 1,000/R300 26 AP-FSF 300 1.8 30.0 1,230 1,000/R400 26 AP-FSF 400 1.8 33.5 1,580 500/R600 26 AP-FSF 600 2.0 40.0 2,300 500/R900 26 AP-FSF 900 2.3 48.0 3,380 200/R
1200 26 AP-FSF 1200 2.3 54.0 4,400 200/R1500 26 AP-FSF 1500 2.5 60.0 5,440 200/R1800 26 AP-FSF 1800 2.8 65.5 6,500 200/R2100 26 AP-FSF 2100 2.8 70.0 7,500 200/R2400 26 AP-FSF 2400 2.8 74.5 8,500 200/R2700 26 AP-FSF 2700 2.8 78.5 9,500 200/R3000 26 AP-FSF 3000 2.8 82.0 10,500 200/R
0.5 25 24 AP-FSF 025 1.5 15.0 240 1,000/R50 24 AP-FSF 050 1.5 18.5 400 1,000/R
100 24 AP-FSF 100 1.5 23.5 720 1,000/R200 24 AP-FSF 200 1.8 31.0 1,310 500/R300 24 AP-FSF 300 2.0 37.0 1,890 500/R400 24 AP-FSF 400 2.0 41.5 2,450 350/R600 24 AP-FSF 600 2.3 50.0 3,620 250/R900 24 AP-FSF 900 2.5 59.5 5,270 200/R
1200 24 AP-FSF 1200 2.8 68.0 6,940 200/R1500 24 AP-FSF 1500 2.8 75.0 8,550 200/R1800 24 AP-FSF 1800 2.8 81.5 10,160 200/R2100 24 AP-FSF 2100 2.8 87.5 11,750 200/R
R = Packing in reel
19
18 TELECOMMUNICATION CABLES
Conductor(mm)
Number of pairs Product code
Nominal sheath
thickness(mm)
Approximate overall
diameter(mm)
Approximate cable weight
(kg/km)
Standard length
(m)
0.65 10 22 AP-FSF 010 1.5 12.5 110 1,000/R25 22 AP-FSF 025 1.5 16.5 340 1,000/R50 22 AP-FSF 050 1.5 21.0 580 1,000/R
100 22 AP-FSF 100 1.8 28.0 1,090 1,000/R200 22 AP-FSF 200 2.0 37.5 2,020 500/R300 22 AP-FSF 300 2.3 45.5 2,980 250/R400 22 AP-FSF 400 2.3 51.5 3,870 250/R600 22 AP-FSF 600 2.5 61.5 5,660 200/R900 22 AP-FSF 900 2.8 74.0 8,320 150/R
1200 22 AP-FSF 1200 2.8 84.0 10,910 150/R
0.9 10 19 AP-FSF 010 1.5 15.5 290 1,000/R25 19 AP-FSF 025 1.5 22.5 610 1,000/R50 19 AP-FSF 050 1.8 29.5 1,120 500/R
100 19 AP-FSF 100 2.0 39.0 2,060 500/R200 19 AP-FSF 200 2.3 53.5 3,930 250/R300 19 AP-FSF 300 2.5 63.5 5,740 200/R400 19 AP-FSF 400 2.8 73.0 7,560 150/R600 19 AP-FSF 600 2.8 87.5 11,090 150/R
R = Packing in reel
AP-FSF : FOAM-SKIN INSULATION AL-PE SHEATHED FILLED CABLE
20
19TELECOMMUNICATION CABLES
ASP-FSF : FOAM-SKIN INSULATION AL-PESHEATHED FILLED CABLE WITH STEEL TAPE ARMOUR
The cable is designed for underground (duct) or lashed to an aerial suspension strand in either exchange area service or trunk service.
APPLICATION :
STANDARD :
TOT/PDITL
21
20 TELECOMMUNICATION CABLES
Conductor(mm)
Number of pairs Product code
Nominal sheath
thickness(mm)
Approximate overall
diameter(mm)
Approximate cable weight
(kg/km)
Standard length
(m)
0.4 50 26 ASP-FSF 050 1.5 17.0 350 1,000/R100 26 ASP-FSF 100 1.5 20.5 570 1,000/R300 26 ASP-FSF 300 1.8 31.0 1,400 500/R600 26 ASP-FSF 600 2.0 40.5 2,530 350/R900 26 ASP-FSF 900 2.3 49.5 3,690 250/R
1200 26 ASP-FSF 1200 2.3 55.5 4,750 250/R1500 26 ASP-FSF 1500 2.5 61.5 5,830 250/R1800 26 ASP-FSF 1800 2.8 67.0 6,920 250/R2100 26 ASP-FSF 2100 2.8 71.5 7,960 250/R2400 26 ASP-FSF 2400 2.8 75.5 9,000 250/R2700 26 ASP-FSF 2700 2.8 79.5 10,020 250/R3000 26 ASP-FSF 3000 2.8 83.0 11,050 250/R
0.5 15 24 ASP-FSF 015 1.5 14.0 240 3,000/R25 24 ASP-FSF 025 1.5 16.0 310 1,000/R50 24 ASP-FSF 050 1.5 19.5 490 1,000/R
100 24 ASP-FSF 100 1.5 24.5 840 1,000/R300 24 ASP-FSF 300 2.0 37.5 2,100 500/R600 24 ASP-FSF 600 2.3 51.5 3,930 350/R900 24 ASP-FSF 900 2.5 61.0 5,660 250/R
1200 24 ASP-FSF 1200 2.8 69.5 7,380 250/R1500 24 ASP-FSF 1500 2.8 76.5 9,050 250/R1800 24 ASP-FSF 1800 2.8 82.5 10,690 250/R
R = Packing in reel
ASP-FSF : FOAM-SKIN INSULATION AL-PESHEATHED FILLED CABLE WITH STEEL TAPE ARMOUR
22
21TELECOMMUNICATION CABLES
Conductor(mm)
Number of pairs Product code
Nominal sheath
thickness(mm)
Approximate overall
diameter(mm)
Approximate cable weight
(kg/km)
Standard length
(m)
0.65 10 22 ASP-FSF 010 1.5 14.5 240 1,000/R50 22 ASP-FSF 050 1.5 23.0 700 1,000/R
100 22 ASP-FSF 100 1.8 30.0 1,260 500/R300 22 ASP-FSF 300 2.3 48.0 3,290 250/R400 22 ASP-FSF 400 2.3 54.0 4,220 250/R600 22 ASP-FSF 600 2.5 64.0 6,090 250/R900 22 ASP-FSF 900 2.8 76.5 8,840 250/R
1200 22 ASP-FSF 1200 2.8 86.5 11,500 250/R
0.9 10 19 ASP-FSF 010 1.5 17.5 380 1,000/R50 19 ASP-FSF 050 1.8 31.5 1,300 500/R
100 19 ASP-FSF 100 2.0 41.0 2,310 500/R300 19 ASP-FSF 300 2.5 66.0 6,180 250/R600 19 ASP-FSF 600 2.8 90.0 11,700 250/R
R = Packing in reel
ASP-FSF : FOAM-SKIN INSULATION AL-PESHEATHED FILLED CABLE WITH STEEL TAPE ARMOUR
23
22 TELECOMMUNICATION CABLES
DSAP-FSF : FOAM-SKIN INSULATION AL-PE SHEATHED FILLED CABLE WITH CORE SEPARATOR
The cable is designed for high frequency transmission and shall be used on junction network for underground (duct) or lashed to an aerial suspension strand.
APPLICATION :
Conductor(mm)
Number of pairs Product code
Nominal sheath
thickness(mm)
Approximate overall
diameter(mm)
Approximate cable weight
(kg/km)
Standard length
(m)
0.65 50 22 FSF-S 050 1.5 27.0 690 1,000/R100 22 FSF-S 100 1.8 35.5 1,270 1,000/R200 22 FSF-S 200 2.3 48.5 2,390 500/R300 22 FSF-S 300 2.5 58.0 3,480 300/R400 22 FSF-S 400 2.8 66.0 4,525 250/R600 22 FSF-S 600 2.8 78.5 6,630 250/R
R = Packing in reel
STANDARD :
TOT/PDITL
24
23TELECOMMUNICATION CABLES
SS-DP : PVC INSULATED AND SELF-SUPPORTED TELEPHONE DROP WIRE
For extending an open wire line or distribution cable pair from a pole or cable terminal to a building.
APPLICATION :
C = Packing in Coil
Number and diameter of
wires in conductor(No / mm)
Nominal diameter of
supporting wire(mm)
Nominal insulation thickness
(mm)
Insulated diameter(mm)
Approximate overall dimensions
(mm)Approximate
weight(kg/km)
Standard length
(m)Conductor Supporting
wire A B
2 X 0.65 1.20 1.00 2.65 3.20 6.1 6.1 43 200/C2 x 0.90 1.20 1.05 3.05 3.35 8.1 6.8 52 200/C
STANDARD :
TOT/PDITL
25
24 TELECOMMUNICATION CABLES
UTP DW(8) : FIGURE 8 UNSHIELDEDTWISTED PAIR DROP WIRE
For use as aerial distribution service wire serving high speed internet service such as ADSL, XDSL, leased line, etc.
APPLICATION :
Conductor(mm)
Nominal Insulation Thickness
(mm)
Approximate Diameter of Drop Wire
(mm)
Nominal Diameter of Supporting
Wire(mm)
Nominal Overall
Diameter of Insulated
Supporting Wire(mm)
Nominal Sheath Thickness
(mm)
Approximate Dimension of
Web(mm)
Approximate Weight(kg/km)
Standard Length
(m)
D x CF & EAB0.5
(24 AWG) 0.37 3.7 - 6.2 1.2 3.3 1.0 0.8 x 0.8 36 200/C
R = Packing in reelC = Packing in Coil
STANDARD :
TOT/PDITL
26
25TELECOMMUNICATION CABLES
IN : POLYPROPYLENE OR POLYETHYLENE INSULATED AND PVC SHEATHED CABLES
For connecting subscriber equipment inside the building.
APPLICATION :
STANDARD :
TOT/PDITL
27
26 TELECOMMUNICATION CABLES
Conductor(mm)
Number of pairs Product code
Nominal insulation thickness
(mm)
Nominal sheath
thickness(mm)
Approximate overall
diameter(mm)
Approximate cable weight
(kg/km)
Standard length
(m)
0.5 4 24 IN 004 0.2 0.9 6.5 35 500/C5 24 IN 006 0.2 0.9 7.0 40 500/C6 24 IN 006 0.2 0.9 7.0 46 500/C8 24 IN 008 0.2 0.9 7.5 57 500/C
10 24 IN 010 0.2 0.9 8.5 68 500/C12 24 IN 012 0.2 0.9 8.5 79 500/C15 24 IN 015 0.2 0.9 9.5 94 500/R16 24 IN 016 0.2 0.9 9.5 100 500/R18 24 IN 018 0.2 0.9 10.0 110 500/R20 24 IN 020 0.2 0.9 10.5 120 500/R25 24 IN 025 0.2 0.9 11.0 145 500/R30 24 IN 030 0.2 0.9 12.0 171 500/R40 24 IN 040 0.2 1.2 14.0 236 500/R50 24 IN 050 0.2 1.2 15.5 286 500/R60 24 IN 060 0.2 1.2 16.5 335 500/R75 24 IN 075 0.2 1.4 18.5 423 500/R
100 24 IN 100 0.2 1.4 21.0 544 500/R150 24 IN 150 0.2 1.4 24.0 787 500/R200 24 IN 200 0.2 1.8 28.0 1,069 500/R300 24 IN 300 0.2 2.0 33.5 1,587 500/R400 24 IN 400 0.2 2.2 38.5 2,100 500/R
R = Packing in reelC = Packing in Coil
IN : POLYPROPYLENE OR POLYETHYLENE INSULATED AND PVC SHEATHED CABLES
28
27TELECOMMUNICATION CABLES
Conductor(mm)
Number of pairs
Product code
Nominal insulation thickness
(mm)
Nominal sheath
thickness(mm)
Approximate overall
diameter(mm)
Approximate cable weight
(kg/km)
Standard length
(m)
0.65 4 22 IN 004 0.25 0.9 7.5 48 500/C5 22 IN 005 0.25 0.9 8.0 57 500/C6 22 IN 006 0.25 0.9 8.0 66 500/C8 22 IN 008 0.25 0.9 9.0 83 500/C
10 22 IN 010 0.25 0.9 9.5 99 500/C12 22 IN 012 0.25 0.9 10.5 115 500/C15 22 IN 015 0.25 0.9 11.0 139 500/R16 22 IN 016 0.25 0.9 11.5 147 500/R18 22 IN 018 0.25 0.9 12.0 163 500/R20 22 IN 020 0.25 1.2 13.5 193 500/R25 22 IN 025 0.25 1.2 14.5 233 500/R30 22 IN 030 0.25 1.2 15.5 275 500/R40 22 IN 040 0.25 1.4 18.0 366 500/R50 22 IN 050 0.25 1.4 19.5 444 500/R60 22 IN 060 0.25 1.4 21.0 522 500/R75 22 IN 075 0.25 1.4 22.5 636 500/R
100 22 IN 100 0.25 1.4 25.5 831 500/R150 22 IN 150 0.25 1.8 31.0 1,250 500/R200 22 IN 200 0.25 2.0 35.0 1,654 500/R300 22 IN 300 0.25 2.4 42.5 2,491 500/R400 22 IN 400 0.25 2.6 48.5 3,288 500/R
R = Packing in reelC = Packing in Coil
IN : POLYPROPYLENE OR POLYETHYLENEINSULATED AND PVC SHEATHED CABLES
29
28 TELECOMMUNICATION CABLES
ST : INSIDE-OUTSIDE STATION WIRE
For general use inside a telephone subscriber station.
APPLICATION :
Conductor(mm)
Number of cores
Nominal insulation thickness
(mm)
Nominal sheath
thickness (mm)
Approximate overall
diameter (mm)
Approximate cable weight
(kg/km)
Standard length
(m)
0.5 2 0.20 0.38 2.8 11 100/C(24 AWG) 4 0.20 0.38 3.2 15 100/C
6 0.20 0.38 3.8 21 100/C
0.65 2 0.25 0.38 3.3 16 100/C(22 AWG) 4 0.25 0.38 3.7 23 100/C
6 0.25 0.38 4.5 32 100/C
C = Packing in coil.
STANDARD :
TOT/PDITL
30
ELECTRICALCHARACTERISTICS
30 TELECOMMUNICATION CABLES
ELECTRICAL CHARACTERISTICS AT 25ºC ±3ºCTYPE AP, AP(8), PAP and AP-SWA
91224262GWA eziS rotcudnoC
9.056.05.04.0)lanimon( retemaid rotcudnoC
Average Mutual capacitance (Cm) at 1,000 Hz
• 2±252±252±252±25regral dna sriap 52
• 4±254±254±254±25sriap 52 naht sseL
Mutual Conductance of any pair at 1,000 Hzshall not exceed 2 2 2 2
Capacitance unbalance pair to pair at 1,000 Hz
• 181181181181 laudividni mumixam ,elbac sriap 6 ot pu roF
• 54545454smr mumixam ,elbac sriap 6 naht erom roF
000,61000,61000,61000,61 muminim ,ecnatsiser noitalusnI
5.821.752.094.441mumixam ,Cº02 ta ecnatsiser rotcudnoC
High voltage test
• 5.46.30.34.2)sdnoces 3( rotcudnoc ot rotcudnoC
• 01010101)sdnoces 3( dleihs ot rotcudnoC
77.011.134.108.1 1,000 Hz, Nominal ta noitaunettA
Capacitance unbalance pair to ground at 1,000 Hz
• 5262526252625262laudividni mumixam ,elbac sriap 6 ot pu roF
• 5262526252625262laudividni mumixam ,elbac sriap 6 naht erom roF
• 475475475475egareva mumixam ,elbac sriap 6 naht erom roF
Minimum bending diameter shall not less than 18 times the cable overall diameter.
mm
nF/km
nF/km
pF/km
pF/km
MΩ-km
Ω/km
kV-dc
kV-dc
pF/km
pF/km
pF/km
micro mho /km
dB/km
32
31TELECOMMUNICATION CABLES
Minimum bending diameter shall not less than 18 times the cable overall diameter.
ELECTRICAL CHARACTERISTICS AT 25ºC ±3ºCTYPES : AP-FSF
91224262GWA eziS rotcudnoC
9.056.05.04.0)lanimon( retemaid rotcudnoC
Average Mutual capacitance (Cm) at 1,000 Hz
• 2±252±252±252±25 regral dna sriap 52
• 4±254±254±254±25sriap 52 naht sseL
Mutual Conductance of any pair at 1,000 Hzshall not exceed 2 2 2 2
The rms pair to pair capacitance unbalance asmeasured on the completed cable at 1,000 Hz shall not exceed
45 45 45 45
006,1006,1006,1006,1muminim ,Cº52 ta ecnatsiser noitalusnI
5.821.752.094.441mumixam ,Cº02 ta ecnatsiser rotcudnoC
High voltage test
• 5.35.30.20.2)sdnoces 3( rotcudnoc ot rotcudnoC
• 0.010.010.50.5)sdnoces 3( dleihs ot rotcudnoC
Capacitance unbalance pair to ground at 1,000 Hz
• 5262526252625262laudividni mumixaM
• 656656656656egareva mumixaM
mm
nF/km
nF/km
pF/km
MΩ-km
Ω/km
kV-dc
kV-dc
pF/km
pF/km
micro mho /km
33
32 TELECOMMUNICATION CABLES
ELECTRICAL CHARACTERISTICS AT 25ºC ±3ºCTYPES : ASP-FSF
91224262GWA eziS rotcudnoC
9.056.05.04.0 )lanimon( retemaid rotcudnoC
Average Mutual capacitance (Cm) at 1,000 Hz
• 2±252±252±252±25 regral dna sriap 52
• 4±254±254±254±25 sriap 52 naht sseL
Mutual Conductance of any pair at 1,000 Hzshall not exceed 2 2 2 2
The rms pair to pair capacitance unbalance asmeasured on the completed cable at 1,000 Hz shall not exceed
45 45 45 45
006,1006,1006,1006,1muminim ,Cº52 ta ecnatsiser noitalusnI
5.821.752.094.441mumixam ,Cº02 ta ecnatsiser rotcudnoC
High voltage test
• 5.35.30.20.2)sdnoces 3( rotcudnoc ot rotcudnoC
• 0.010.010.50.5)sdnoces 3( dleihs ot rotcudnoC
Capacitance unbalance pair to ground at 1,000 Hz
• 5262526252625262laudividni mumixaM
• 656656656656egareva mumixaM
Minimum bending diameter shall not less than 18 times the cable overall diameter.
mm
nF/km
nF/km
pF/km
MΩ-km
Ω/km
kV-dc
kV-dc
pF/km
pF/km
micro mho /km
34
33TELECOMMUNICATION CABLES
ELECTRICAL CHARACTERISTICS AT 25ºC ±3ºCTYPES : DSAP-FSF
Conductor Size AWG 22
Conductor diameter (nominal) 0.65
Average mutual capacitance of any reel at 1,000 Hzshell not exceed 52±2
Mutual Conductance of any pair at 1,000 Hzshall not exceed 2
The rms pair to pair capacitance unbalance asmeasured on the completed cable at 1,000 Hz shall not exceed
45
006,1 muminim ,Cº52 ta ecnatsiser noitalusnI
1.75mumixam ,Cº02 ta ecnatsiser rotcudnoC
High voltage test
• 5.3)sdnoces 3( rotcudnoc ot rotcudnoC
• Conductor to shield (3 seconds) 10
Capacitance unbalance pair to ground at 1,000 Hz
• Maximum individual 2625
• Maximum average 656
Minimum bending diameter shall not less than 18 times the cable overall diameter.
mm
nF/km
pF/km
MΩ-km
Ω/km
kV-dc
kV-dc
pF/km
pF/km
micro mho /km
35
34 TELECOMMUNICATION CABLES
ELECTRICAL CHARACTERISTICS AT 20ºCTYPES : IN
Conductor size
(mm)0.5 0.65
Conductor resistance, maximum Ω/km 92.0 58.0Average mutual capacitance at 1,000 Hz,maximum average μF/km 0.070 0.070
Dielectric strength between conductors (3 seconds) kVdc 3.0 3.0Insulation resistance, minimum MΩ-km 16,000 16,000
ELECTRICAL CHARACTERISTICS AT 20ºCTYPES : ST
Conductor size
(mm)0.5 0.65
Conductor resistance, maximum Ω/km 92.0 58.0Dielectric strength between conductors (3 seconds) kVdc 3.0 3.0Insulation resistance, minimum MΩ-km 16,000 16,000
36
35TELECOMMUNICATION CABLES
ELECTRICAL CHARACTERISTICS AT 20ºCTYPES : SS-DP
UTP DW(8) : FIGURE 8 UNSHIELDED TWISTED PAIR DROP WIRE
Conductor size
(mm)0.65 0.9
Conductor resistance, maximum Ω/km 57.1 28.5Dielectric strength (1 minute in water) kVrms 1.5 1.5Insulation resistance, minimum MΩ-km 400 400
Conductor size
(mm)0.5
Conductor Resistance at 20 ± 1°C, maximum Ω/km 90.2Insulation Resistance at 25 ± 3°C, minimum MΩ-km 16,000Resistance Unbalance at 20 ± 1°C, maximum % 5.0Maximum Attenuation at 20°C
• 1 kHz dB/km 1.4• 150 kHz dB/km 6.4• 772 kHz dB/km 12.8• 1,100 kHz dB/km 14.5
Average Mutual Capacitance at 1,000 ± 100 Hz, 25 ± 3°C, minimum μF/km 0.040High Voltage Test between Tip and Ring (3 seconds) kV-dc 3.0
37
TELEPHONE AND COMMUNICATION CABLES
TELEPHONE AND COMMUNICATION CABLESTELEPHONE AND COMMUNICATION CABLESTELEPHONE AND COMMUNICATION CABLESTELEPHONE AND COMMUNICATION CABLESTELEPHONE AND COMMUNICATION CABLESTELEPHONE AND COMMUNICATION CABLES
QUALITY ASSURANCE
Quality Management System
Environmental Management System
Occupational Health and Safety Management System
TELEPHONE AND COMMUNICATION CABLES