5.2 detection and monitoring of pollution. direct measurement is performed by monitoring the level...

18
5.2 DETECTION AND MONITORING OF POLLUTION

Upload: treyton-lavell

Post on 14-Dec-2015

213 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: 5.2 DETECTION AND MONITORING OF POLLUTION.  Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake

5.2 DETECTION AND MONITORING OF POLLUTION

Page 2: 5.2 DETECTION AND MONITORING OF POLLUTION.  Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake

Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake or temperature levels in a lake or stream. An indirect method would monitor the effects of the pollutants on other factors, e.g. dissolved oxygen, B.O.D., presence or absence of indicator species (see 5.2.3)

Page 3: 5.2 DETECTION AND MONITORING OF POLLUTION.  Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake

Some direct measurements might include: measuring temperature in several locations along

the length of a river, or at different times during the year with thermometers as an indication of thermal pollution. Take baseline measurements and then monitor in a systematic manner to determine changes.

measuring nitrate levels/ammonia levels/chloride levels as an indication of nutrient overload. Use the same process as above

measuring TSS (Total Suspended Solids) or TDS (Total Dissolved Solids) as an indication of material entering the lake or stream. (see next slide)

Page 4: 5.2 DETECTION AND MONITORING OF POLLUTION.  Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake

TSS (Total Suspended Solids) or TDS (Total Dissolved Solids)

Page 5: 5.2 DETECTION AND MONITORING OF POLLUTION.  Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake

BOD

BOD is the measure of the amount of dissolved oxygen that is used by aerobic bacteria to break down the organic matter in a specific volume of water.

Therefore the greater the amount of organic matter (sewage, agricultural run-off, fertilizer etc.) in the body of water, the higher the BOD will be. The less organic matter, the lower the BOD. It is not uncommon for the BOD of incoming water to a sewage treatment plant to be in the range of 120. After treatment the BOD of the same water is around 5.

Page 6: 5.2 DETECTION AND MONITORING OF POLLUTION.  Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake

The standard technique for measuring the BOD of body of water is the 5-Day BOD test or BOD5. This is done by measuring the DO (dissolved oxygen) on day 1 and and again on day 5 while keeping the samples at 200C in the dark during that time. This ensures that only respiration is going on and not photosynthesis. Refer to Topic 2 under Gross and Net primary productivity

Page 7: 5.2 DETECTION AND MONITORING OF POLLUTION.  Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake
Page 8: 5.2 DETECTION AND MONITORING OF POLLUTION.  Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake

Factors Controlling BOD and DO A major source for DO comes from the atmosphere When the surface of the water is disturbed as in rapids or

water falls, then a greater the amount of oxygen will become dissolved in it.   

Temperature is a major factor. An increase in temperature a decrease in DO. i.e the colder the water the greater the concentration of dissolved oxygen in the water.

Low DO from man-made source of heating bodies of water (effluent from nuclear power plants used to cool the reactors)

BOD is affected by respiration or lack of respiration by microorganisms and by the increase in organic matter (plant and animal) and organic waste and sewage.

Organic effluent can be treated by pumping it with large volumes of air.

Page 9: 5.2 DETECTION AND MONITORING OF POLLUTION.  Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake

BOD Level

BOD Level(in ppm) Water Quality

1 - 2Very GoodThere will not be much organic waste present in the water supply.

3 - 5 Fair: Moderately Clean

6 - 9Poor: Somewhat PollutedUsually indicates organic matter is present and bacteria are decomposing this waste.

100 or greaterVery Poor: Very PollutedContains organic waste.

Page 10: 5.2 DETECTION AND MONITORING OF POLLUTION.  Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake

Indirect measurement

Indirect measurement involves the monitoring and measurement of organisms in the ecosystem and more specifically indicator species or index species. These are species that by virtue of their abundance or absence will indicate the level of pollution in that ecosystem.

Page 11: 5.2 DETECTION AND MONITORING OF POLLUTION.  Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake

Some important indicators are: fish bottom fauna algae bacteria

Page 12: 5.2 DETECTION AND MONITORING OF POLLUTION.  Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake

Stonefly Adult

Page 13: 5.2 DETECTION AND MONITORING OF POLLUTION.  Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake

Sludge Worm

Page 14: 5.2 DETECTION AND MONITORING OF POLLUTION.  Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake

Comparison of diatoms to blue-green algae provides similar information

Measuring the coliform levels can also indicate the presence of sewage dumping in the ecosystem.

Page 15: 5.2 DETECTION AND MONITORING OF POLLUTION.  Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake

Diatoms

Page 16: 5.2 DETECTION AND MONITORING OF POLLUTION.  Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake

Fecal Coliform

Page 17: 5.2 DETECTION AND MONITORING OF POLLUTION.  Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake

Blue-green algae

Page 18: 5.2 DETECTION AND MONITORING OF POLLUTION.  Direct measurement is performed by monitoring the level of the pollutant itself, e.g. nitrates in a lake

Overall the diversity of the whole system is often the best indicator while a general rule to follow is that presence is better evidence than absence.