5-ag_ss02_e2 zxmsg 5200 (v3.1) system structure(ppt) 73p
DESCRIPTION
descriptionTRANSCRIPT
ZXMSG 5200(V3.1) SystemStructure
ZTE University
1
Course Object
nnn Understand interfaces and functions of IPMSAN
nnn Master network and service of IP MSAN
nnn Master system structure of IP MSAN
nnn Master boards of IP MSAN
2
System Overview
nnn Network Evolutionnnn Functionsnnn Interfacesnnn Technical specifications
3
Network Evolution--MSAN
4
Network Evolution--MSAG
5
Functionsl Support H.248, MGCP or SIP.
l Support real time transport protocol RTP/RTCP.
l Support code and encode arithmetic G.711,G.729, G.723.1.
l Support broadband interfaces likeADSL/ADSL2+, VDSL2, SHDSL, GPON andEthernet.
l Support PSTN service, ISDN service, FAX ser-vice, V5 interface, xDSL service, CES serviceand GPON service.
6
InterfacesØØØ Subscriber-side Interface
l POTS analog subscriber interface
l ISDN 2B+D/30B+D subscriber interface
l xDSL subscriber interface
l FE/GE Ethernet interface
l GPON interface
l E1 interface
7
InterfacesØØØ Network-side Interface
l FE/GE/10GE Ethernet/Optical interface
l E1 interface
l ATM interface
l Maintenance serial port
l Maintenance network port
l Environment&powermonitor port
8
Technical Specificationsl Capacity:
à 1856 analog subscribers
à 1856 ADSL2+ subscribers
à 928 VDSL2 subscribers
à Minimum 240 VOIP ports
l BHCA: 20 K
l Codec:
à G.711
à G.729a
à G.723.1
9
Network and Service
nnn Network Typennn Hair-pinnnn Self-switch
10
Network Type 1--IP MSAN in NGN
11
Network Type 2--MSAN Upgrade to MSAG
12
Hair-pin
13
Self-switch
14
System Structure
nnn Cabinetsnnn Shelvesnnn Working Principlennn Control and Switch Cardsnnn Packet Processing and Resource Cardsnnn Uplink cardsnnn Ethernet cardsnnn Narrowband Subscriber cardsnnn Broadband Subscriber Cardsnnn Power Cardnnn Other Cards
15
CabinetsCabinet Dimension
(mm)(H×W×D)
Weight(kg)
PowerConsump-tion (W)
Type User Num-ber(nar-rowband)
User Num-ber(broad-band)
19D06H20 2000×600×600
250 1750 indoor 1856 1856
OUT60 1600×1500×780
620 1050 outdoor 1088 1152
16
IP MSAN Shelf Type
17
IP MSAN Shelf Type
18
19D06H20 Shelf Structure
19
OUT60 Shelf Structure
20
Working Principle
21
Working Principlel Narrowband service
After entering the TDM switch of the GIS, suchnarrowband service as POTS transfers voice intoIP packet by the voice compression function of theMPRB. The service switches to the CNIC throughan Ethernet switching chip for Network AddressTranslation (NAT), and then enters the IP networkfrom the uplink interface by Ethernet switching.
l Broadband service
Direct forward to Ethernet switching and uplink tometro Ethernet network
22
Control and Switching CardsCard Full Name Port & DescriptionGIS Giga ethernet integrated
control and switching card4 K VLANs,two GE plustwo FE uplink ports,GE starcascading between shelves
GISX Giga ethernet integratedcontrol and switchingcard typeX
10 GE uplink ports,1:1 vlan
23
Packet Processing and Resource CardsCard Full Name FunctionMPRB Packet processing and
resource card type BVOIP and resource card forvoice call,240 channels
24
Uplink CardsCard Full Name Function Port & DescriptionSUPI Slave shelf uplink
interface cardUplink, cascade One GE or one FE
uplink port (only validin the slave shelf)
EUX Ethernet uplinkinterface card
Uplink, cascade Two uplink FEelectrical ports, fourFE cascading portsfor control unit andbroadband services
GEI 1000 M ethernetcascade interfacecard
Uplink, cascade Two uplink FEelectrical ports, twouplink GE optical ports
25
Ethernet CardsCard Full Name Function Port & DescriptionGETC 1000 M ethernet
interface cardEthernet layer 2switching function
One or two GE opticalinterface
GETI 100 M ethernetinterface card
Ethernet layer 2switching function
Four FE ethernetinterface
GATI ATM optical interfacecard
Conversion of signalsbetween ATM andethernet
One ATM opticalinterface
26
Narrowband Subscriber CardsCard Full Name Function Port & DescriptionALC Analog line card POTS access 32 analogsubscriber
portsRALC Reverse analog line
cardPOTS access andreversed polarity
32 analogsubscriberports
FLC Far-end analog linecard
POTS access,reversed polarity, 12KC/16 KC meteringpulse and longdistance functions
16 analog subscriberports
DLCE Digital subscriber card Basic rate interface forISDN. Transceiving of2B+D data and formatconversion
2B+D channel andU interface functionof the ISDN physicallayer
27
Broadband Service CardsCard Full Name Function Port & DescriptionGADL 16-port ADSL
subscriber cardADSL/ADSL2/ADSL2+ subscriber access
16 ADSL/ADSL2/AD-SL2+ ports
GAGL 32-port ADSLsubscriber card
ADSL/ADSL2/ADSL2+ subscriber access
32 ADSL/ADSL2/AD-SL2+ ports
GVDL 16-port VDSL2subscriber card
Conversion fromVDSL to ethernet port;receiving eight VDSLsignals; VLAN andmulticast functions
16 VDSL2 ports
GSDL 16-port SHDSLsubscriber card
SHDSL subscriberaccess
16 SHDSL ports
GSDLB 16-port SHDSL.bissubscriber card
SHDSL.bis subscriberaccess, high-rate,high-centralizationand low powerconsumption
16 SHDSL.bis ports
28
Power CardCard Full Name Function Port & DescriptionPOWER K Power Card Secondary power and
ringing currentPower connector onthe backplane
29
OthersCard Full Name Function Port & DescriptionODTI Octal digital interface
cardConversion of signalsbetween two 8 MbpsHW and eight E1s
8 E1 ports
CEE 16–port E1 interfacecircuit emulation card
Realizing TDMoIPthrough circuitemulation mode
16 E1/T1 ports
GPOI 4–port GPONsubscriber card
Conversion betweenGEM frame andethernet frame
4 GPON ports
GILCA Giga Integrated LineCard
Functions of ALC cardand GADL card
16 integratedADSL/POTS ports
GELC Giga High-densityIntegrated Line Card
Functions of ALC cardand GADL card
32 integratedADSL/POTS ports
EPC Environment powercontrol card
Collections ofenvironment alarmand power data;reporting localalarm and real-timemonitoring data at thesame time
-
30
Board Principle
nnn Board Functionnnn Board Panelnnn Board Indicatorsnnn Board Interfaces
31
GIS/GISXl Performs management functions and circuit sta-
tus scanning of downlink subscriber line cards.
l System control and H.248 managements.
l One card has 4 E1s interfaces.
l Performs TDM switching (2K*2K),Ethernetswitching and network functions.
l Supports active/standby working modes.
l Provides two RS-232 ports. One is connected toenvironment power monitoring module; other isconnected to NMS computer.
l GISX provides two 10 G optical ports for uplink.
32
GIS/GISX Panel
33
GIS/GISX Panel
34
GIS/GISX PanelLED Color Status DescriptionRUN Green Flashing Card is running normally.ALM Red ON Card is faulty.M/S Green ON Card is active.NACT Green Flashing Narrowband service is normal.BACT Green Flashing Broadband service is normal.DT Green ON 2 Mbps trunk is running normally.GE1 Green Flashing Uplink port 1 is running normally.GE2 Green Flashing Uplink port 2 is running normally.
35
MPRBl TONE
l DTMF
l CID
l Conference call
l 240 channels for VoIP processing resources
36
MPRB Panel
37
MPRB PanelLED Color Status DescriptionRUN Green Flashing Card is running normally.ALM Red ON Card is faulty.DSP1 Green Flashing DSP1 is working normally.DSP2 Green Flashing DSP2 is working normally.
38
ALCl Provides 32 analog subscriber lines
l Subscriber supply voltage: -48 V
l Subscriber supply current: 0.02 A
l Ringing current voltage: 75
l Card power consumption: 40 W
39
ALC Panel
40
ALC PanelLED Color Status DescriptionRUN Green Flashing Card is running normally.ALM Red ON Card is faulty.HOOK Green ON One or more subscribers hook-off.
41
DLCEl Provides 2B+D interface and performs U inter-
face function of ISDN physical layer.
l Provides self loop detection and over voltageprotection.
l Performs link layer processing for D channel sep-aration based on I440/I441 protocol.
l Sends the processed signaling to GIS, and pro-vides communication with ISDN network layer.
l Allocates time slots for two B channels based onGIS instruction.
l Provides test ports for user test cards.
42
DLCEl Provides remote power supply via U interface,
when local system fails to provide power supplyto Network Terminal1 (NT1).
43
DLCE Panel
44
DLCE PanelLED Color Status DescriptionRUN Green Flashing Card is running normally.ALM Red ON Card is faulty.U1~U8 Green ON The corresponding U interface is activated.
45
GADLl GADL card is connected to other Ethernet
switching devices through Ethernet interface.
l Communicates with main control card throughHDB protocol to implement related NM functions.
l Provides 16-channel ADSL interface to imple-ment ATM cell access.
l Follows G.dmt and G.Lite standards.
l Contains a built-in 16-channel splitter.
46
GADL Panel
47
GADL PanelLED Color Status DescriptionRUN Green Flashing Card is running normally.ALM Red ON Card is faulty.ACT Green ON Link is UP.
48
GAGLl GAGL card is connected to other Ethernet
switching devices through Ethernet interface.
l Communicates with control and switching cardvia HDLC to implement NM functions.
l Provides 32-channel ADSL interface to imple-ment ATM cell access.
l Follows G.dmt and G.Lite standards.
l Works with PAUN (32-channel ADSL splittercard).
49
GAGL Panel
50
GAGL PanelLED Color Status DescriptionRUN Green Flashing Card is running normally.ALM Red ON Card is faulty.ACT Green ON Link is up.
51
PAUNPANU card is 32-channel splitter card with 3 U height.It is plugged-in the slot under GAGL card.
52
PAUN
53
EUX Panel
54
EUX Panell X5, X6 are used for Ethernet uplink.
l X4 is used for cascading.
55
IEBA Panel
56
IEBA PanelInterface Description1 68-core socket, E1 cable interface2 RJ-9 interface for debugging cable3 RJ-9 interface for monitoring cable connected
to EPC or EPM card
57
IEBC Panel
58
IEBC PanelInterface Description1 Uplink interface (GE optical interface or FE
electrical interface)2 Uplink interface (GE optical interface or FE
electrical interface)3 DB-50 cascade socket, which supports 3
slave frames
59
POWER Kl Supplies secondary power and ringing current
for subscriber layer.
l Supplies four types of voltages: +5 V, -5 V, -48 Vand 75 V AC ringing current.
60
POWER K Panel
61
POWER K PanelLED Color Status DescriptionALM Red ON Card is faulty.-48V Green ON -48 V supply is normal.Ring Green Flashing Card is running normally.+5V Green ON +5 V supply is normal.+5VJ Green ON +5VJ supply is normal.-5V Green ON -5 V supply is normal.
62
PEB
63
PEBInterface Description1 Three-core power socket2 POWER K control interface; This interface can
be connected to EPC or EPM card.3 POWER K detection interface; It is connected
to EPC or EPM card.4 Interconnection test interface5 Interconnection test interface
64
EPCl EPC card provides environment monitoring pa-
rameters such as temperature, humidity, smoke,dust, fog and moist.
l EPC is mainly used to collect environment andpower data from external interface.
l EPC card also detects equipment related to out-put control, and reports the local alarm data andreal-time data simultaneously. This card is usedin standard shelf.
65
EPC Panel
66
EPC PanelLED Color Status DescriptionRUN Green Flashing Card is running normally.OTH Red ON Card is faulty.SMK Red ON Smoke is detected.HUM Red ON Humidity exceeds the threshold limits.FLOW Red ON Water level is above the limit.DOOR Red ON Door is open.TEMP Red ON Temperature exceeds the threshold limits.POWR Red ON Power supply is abnormal.
67
EPEB PanelEPEB is the extension card for EPC card. It isplugged-in the slot under EPC card. The front panelhas the interface to connect the monitoring cable.
68
EPEB Panel
69
TSLCl Loop line testing
l Internal line test
l Subscriber telephone function test
70
TSLC Panel
71
TSLC PanelLED Color Status DescriptionRUN Green Flashing Card is running normally.ALM Red ON Card is faulty.Test Green Flashing Test is ON.
72
73