3 gt auxiliaries

Upload: sam

Post on 05-Apr-2018

229 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/31/2019 3 GT Auxiliaries

    1/18

    May 24, 2012 PMI Revision 00 1

    GT AUXILIARYSYSTEMS

  • 7/31/2019 3 GT Auxiliaries

    2/18

    May 24, 2012 PMI Revision 00 2

    Shaft Driven Auxiliaries

  • 7/31/2019 3 GT Auxiliaries

    3/18

    May 24, 2012 PMI Revision 00 3

    GT Support Systems

    On - Base systems

  • 7/31/2019 3 GT Auxiliaries

    4/18

    May 24, 2012 PMI Revision 00 4

    GT Support Systems

    Inlet System Air Filter, Air intake duct , APU

    Exhaust System

    Exhaust duct , Exhaust dampers, By-pass stack

    Enclosure

    Ventilation system

    Fire fighting system

    Water wash system

    Control cabinet

    Motor Control Centre

    D.C. System

    Oil mist eliminator

  • 7/31/2019 3 GT Auxiliaries

    5/18

    May 24, 2012 PMI Revision 00 5

    Enclosure

    On-Base or Off-Base type

    Noise containment

    Protection from weather Fixed volume for ventilation

    Part of the package

    Exterior appearance

  • 7/31/2019 3 GT Auxiliaries

    6/18

    May 24, 2012 PMI Revision 00 6

    Exhaust System

    Options in configuration

    Exhaust duct and by-pass stack

    Diverter damper

    Guillotine Damper

    Generally internally insulated

    Stack Size based on emission requirements

  • 7/31/2019 3 GT Auxiliaries

    7/18

    May 24, 2012 PMI Revision 00 7

    Ventilation System

    Heat dissipation to maintain safe temperature

    To limit hazardous area expansion

    Positive pressure ventilation Induced draft ventilation

    2x 100% philosophy for vent fans

    Control dampers available

  • 7/31/2019 3 GT Auxiliaries

    8/18

    May 24, 2012 PMI Revision 00 8

    Oil Mist Eliminator

    Recovery of oil vapour

    Fan and coalescent filters used

    Common for entire GTG and gear box

    Located outside GTG

  • 7/31/2019 3 GT Auxiliaries

    9/18

    May 24, 2012 PMI Revision 00 9

    Control Cabinet

    Local control room

    Houses all control and electrical systems

    Self contained control room

    Usually used for outdoor installations

  • 7/31/2019 3 GT Auxiliaries

    10/18

    May 24, 2012 PMI Revision 00 10

    Motor Control Centre

    Dedicated LT MCC for GT auxiliaries

    Tailored to meet specific operational needs

    Auto-changeover possible

  • 7/31/2019 3 GT Auxiliaries

    11/18

    May 24, 2012 PMI Revision 00 11

    D.C.System

    125V DC system

    Battery and Charger

    Lead-Acid/ SMF / Ni-Cad batteries

    Dual cum Boast float charger

    Sized to meet operational needs

  • 7/31/2019 3 GT Auxiliaries

    12/18

    May 24, 2012 PMI Revision 00 12

    Control System

    Microprocessor Based Integrated Controls

    Novel Speedtronic Mk-V system of GE Self contained control and protection system

    State of art communication features

    Triple redundancy in processors and controls

  • 7/31/2019 3 GT Auxiliaries

    13/18

    May 24, 2012 PMI Revision 00 13

    Control System

    Major Protections

    Overspeed

    Over temperature

    Loss of flame

    Vibration

    Lube oil / Hydraulic oil parameters

    Fire

    Loss of ventilation

    Electrical protections

    Customer specfic

  • 7/31/2019 3 GT Auxiliaries

    14/18

    May 24, 2012 PMI Revision 00 14

    Control System

    Triple redundancy in processors

    Separate processors for control and protection

    Remote control possible

    Networking of control systems

    Integrated control systems of Co-gen / CCP

    Single push button start

    True black start capability

  • 7/31/2019 3 GT Auxiliaries

    15/18

    May 24, 2012 PMI Revision 00 15

    Water Washing System

    On-line / Off-line Washing Washing of fouled compressor

    For heavy fuels turbine washing envisaged

    Use of detergent for cleaning

    Manifolds provided on base

    On-line washing reduces need for frequent Off line washing

    Self contained water washing skid provided

  • 7/31/2019 3 GT Auxiliaries

    16/18

    May 24, 2012 PMI Revision 00 16

    Fire-Fighting System

    Dedicated F-F system for GT & auxiliaries

    Most times Generator included

    Co2 / FM200 based system

    Meets NFPA requirements

    Initial and Extended discharge philosophy

    Cylinder banks for storage

    Separate control system

    On-line weighing system introduced

    Detection on Heat-rise / UV principle

  • 7/31/2019 3 GT Auxiliaries

    17/18

    May 24, 2012 PMI Revision 00 17

    Water Washing System

    On-line / Off-line Washing Washing of fouled compressor

    For heavy fuels turbine washing envisaged

    Use of detergent for cleaning

    Manifolds provided on base

    On-line washing reduces need for frequent Off line washing

    Self contained water washing skid provided

  • 7/31/2019 3 GT Auxiliaries

    18/18

    May 24, 2012 PMI Revision 00 18