RunwayIce warning systems

Page 2: 2012 04 24 Runway Ice Warning System

Benefit – Ice warning systems» permanent control of the runway for

24h a day and 7 days a week is possible.

» flight security can be optimized

» permanent acquisition of data will optimize the winter maintenance and in special the use of deicing fluids

» help to minimize control trips and organize them more effective

Page 3: 2012 04 24 Runway Ice Warning System

Benefit – Ice warning systems» Certified acquisition of data

» Automatic backup and verification of the runway status (data) » Use in case of refund

examination

» Use of the runway status for airlines possible

Page 4: 2012 04 24 Runway Ice Warning System

System structure

Page 5: 2012 04 24 Runway Ice Warning System

Passive & active RWY sensors

Page 6: 2012 04 24 Runway Ice Warning System

Passive Runway sensor

IRS31-UMB

» Measurement principle:Passive salt concentrations- and freeze point temperature measurement by measuring the conductivity dependent on water film height

Page 7: 2012 04 24 Runway Ice Warning System

Passive Runway sensor

IRS31-UMB

Measurement of…» RWY surface temperature» RWY depth temperature in 5cm and 30cm» Water film height up to 4mm» RWY condition (dry, damp, wet, critical

wetness, critical (snow/ice))

Page 8: 2012 04 24 Runway Ice Warning System

Passive Runway sensor

IMPORTANT:No measurement of freezing point temperature in runway applications with IRS31-UMB possible because of use of deicing fluid

Page 9: 2012 04 24 Runway Ice Warning System

Active runway sensor

ARS31-UMB

» Measurement principle:Measurement of salt concentration and freeze point temperature by active cooling and heating of the sensor surface.

Page 10: 2012 04 24 Runway Ice Warning System

Active runway sensor

Measurement of…» Freezing point temperature

(independent of used deicing fluid)» Deicing fluid concentration

Page 11: 2012 04 24 Runway Ice Warning System

System structure

Only with combination of passive and active RWY sensor determination of following parameters possible:

» RWY surface temperature» RWY depth temperature (5+30cm)» Water film height up to 4mm» RWY condition (dry, damp, wet, critical wetness,

critical (snow/ice))» Freezing point temperature» Deicing fluid concentration

Page 12: 2012 04 24 Runway Ice Warning System

All-in-one weather station

Page 13: 2012 04 24 Runway Ice Warning System

All-in-one weather station

WS600-UMB

Measurement of…» Air temperature» Rel. Humidity» Dew point» Air pressure» Wind speed and wind direction» Precipitation intensity» Precipitation type

Page 14: 2012 04 24 Runway Ice Warning System

References

» Airport Düsseldorf, Germany

» Airport Paderborn, Germany

» Airport Turin, Italy

» Military Airport Jever, Germany» Military Airport Spangdahlem,

Germany

Page 15: 2012 04 24 Runway Ice Warning System

G. Lufft Mess- und Regeltechnik GmbH

Gutenbergstr. 2070736 Fellbach

Web: www.lufft.com || E-Mail: [email protected]