Direct Digital Imaging - DDI(Drystar)
Information about DrystarAgfa HealthCare India Private Limited,
2ndFloor, B 14, Road No. 1,Wagle Industrial Estate,Thane (West) 400 604
-
2 Company Confidential
FFDM, CR, DR, CT, MR,DSA, digital R&F508 dpi (50 m px)DRYSTAR DT2 filmDmax > 3.2
With mammography printing option DRYSTAR DT2 Mammo film, Dmax > 3.6
DRYSTAR AXYS
Agfa Hardcopy Imagers & Film Assortment
De-centralized Printing
Centralized Printing
DRYSTAR 5302
CR, DR, DSA, digital R&F320 dpi (79 m px)DRYSTAR DT2 filmDmax > 3.1
DRYSTAR 5300
CT, MR, DSA, digital R&F, CR, DR,320 dpi (79 m px)DRYSTAR DT2 filmDmax > 3.1
DRYSTAR 5503
FFDM, CT-MS, CT-SS, MR, CR, DR, US, NM508 dpi (50 m px)DRYSTAR DT2 filmDmax > 3.1
With mammography printing option DRYSTAR DT2 Mammo film, Dmax > 3.7
Software enhancement to bring DRYSTAR technology on wet laser sharpness level (Scopix LR 5200).
Over 40,000 Medical
Imagers installed
worldwide
-
3 Company Confidential
Basic Principle of DDI:
- Single Stage Process
- Black / White Densities created by TPH
- Film is sensitive to heat only
Single Step Printing
-
4 Company Confidential
Thermal Print Head (TPH)
Thermal Sensitive Film
Drum to transport the film
Direct Digital Imaging (DDI)
DDI Technology - Direct Thermal Printing
Resistors
Thermal Print Head (TPH)
-
5 Company Confidential
A#Sharp Imaging Technology
The main cause for the lower sharpness is heat spread and storage in the thermal print head TPH.
Ideal TPH
Requested image
Real TPH
Printed image
-
6 Company Confidential
Features of Dry Imager: Direct Digital Imaging1. DDI films can be loaded in Day Light, as they are sensitive to heat only
2. DDI is a much newer technology
3. DDI imagers require very less warm up time (5 minutes or less)
4. DDI imagers consume amazingly low power, (to the tune of 700 W Max.)
5. Footprint of Agfa DDI imagers, Drystar Series, is small, saving space
6. DDI imagers produce a square type pixel, as Image on the film
7. Complete range of Drystar to fulfill the need of radiology & imaging
8. Ecologically friendly imager, without use of any harmful chemicals
9. Installed base of over 2,350 imagers for Agfa alone in India
-
7 Company Confidential
Photo-Thermal Technology (Competition)
Technically complex and delicate process
2 STEPS
1 Light exposure
2 Heat processing laser exposure
thermal processing on drum2
1
Light sensitive film
-
8 Company Confidential
Difference between DDI and Dry Laser:DDI
Single step printingEco-friendly filmsFreehand daylight loadingLess Warm up timeLess Components / ServiceLess power consumptionHigh shelf life (pre & post print)Compact to occupy less spaceDirect DICOM ready
Dry LaserTwo step printingFilms contain developing chemicals
Cartridge daylight loadingHigher Warm up time (> 15 mins)More Components / ServiceHigher power consumptionEqual shelf life (pre & post print)Occupy larger spaceRequire interface for DICOM
-
9 Company Confidential
No Imager is pure LASER:
Any Laser Exposure Thermal Development (LETD) Imager, popularly called as Dry Laser Imager, as the
name suggests involves Thermal process within the two staged printing process
:Stage I:Film (light sensitive) which contains embedded chemicals is exposed by a Laser beam. Embedded chemicals act to
actually create the Gray shades:Stage II:
Non reacted part of the emulsion (deemed white part) is removed by a thermal heater. Frequent replacements are required for the filters to keep this fixing process smooth.
-
10 Company Confidential
Perception of Resolution:DDI
- Perceived resolution is better, even at the same addressability
Dry Laser- Perceived resolution is less, even at the same addressability
Conversion for commonly used interchangeable technical terms
-
11 Company Confidential
Significance of correct Resolution:DDI
- Modality CR Mammo(Input Resolution of 10 lp/mm)
- Imager(Output Resolution of 10 lp/mm)
- True Size Printing
Dry Laser- Modality CR Mammo
(Input Resolution of 10 lp/mm)- Imager
(Output Resolution of 12.5 lp/mm)- True Size Printing
?
Higher resolution of Imager is not always beneficial
-
12 Company Confidential
Other technical parameters:Access Time: Better
DDI has much lesser access time contributing to meaningful throughput. One prints many different films on printer; rarely the same film many times.
Gray Scale Resolution: =
Throughput: ~More or less is very close to each other in a practical environment
Number of Input trays: =
Number of supported film sizes: BetterUse of 10 X 12 or 11 X 14 allows maximum utilization of space for images from the modality, typically with the aspect ratios used in medical diagnosis
Maximum Density: Slightly Lesser
Black Border: Not Available
-
13 Company Confidential
Imager Model: Drystar 5300
Ideal for CT / MRI Printing
Mounting Table TopOn-Line Tray 1
Foot Print 27.5 X 31. 5 InchesWeight 55 Kg
Resolution 320 Pixels / "GrayScale 12 Bits / PixelThroughput 70 / Hour
Sizes14 X 17 "14 X 14 "11 X 14 "
Applications CTMRI
-
14 Company Confidential
Imager Model: Drystar 5302
Ideal Centralized Printing
Mounting Table TopOn-Line Tray 2
Foot Print 28.7 X 28.1 InchesWeight 90 Kg
Resolution 320 Pixels / "GrayScale 12 Bits / PixelThroughput 75 / Hour
Sizes
14 X 17 "14 X 14 "11 X 14 "10 X 12 "8 X 10 "
Applications
CTMRICRUSNM
-
15 Company Confidential
Imager Model: Drystar AxysMounting Table Top
On-Line Tray 2Foot Print 28.7 X 28.1 Inches
Weight 90 KgResolution 508 Pixels / "GrayScale 14 Bits / PixelThroughput 75 / Hour
Sizes
14 X 17 "14 X 14 "11 X 14 "10 X 12 "8 X 10 "
Applications
CTMRICRUSNM
MammoMammography ready Imager
-
16 Company Confidential
Imager Model: Drystar 5503Mounting Floor
On-Line Tray 3Foot Print 28.3 X 28.1 Inches
Weight 193 KgResolution 508 Pixels / "Throughput 100 / Hour
Sizes
14 X 17 "14 X 14 "11 X 14 "10 X 12 "8 X 10 "
Applications
CTMRICRUSNM
Mammo
Centralized Imager for all Applications
-
17 Confidential
DRYSTAR DT1 Film
Media for the DRYSTAR 2000, 3000, 4500 and 4500 M :
DT1B (blue base) DT1C (clear base) in media sizes
8 x 10 (20 x 25 cm), 10 x 12 (25 x 30 cm), 11 x 14 (28 x 35 cm), 14 x 17 (35 x 43 cm),
First generation Direct Digital grayscale medium
Max. optical density >3.0 Secure archiving up to 20 years (when
stored under proper temperature conditions)
DYSTAR 2000
DRYSTAR 3000
DRYSTAR 4500DRYSTAR 4500 M
-
18 Confidential
DRYSTAR DT2 Film
Media dedicated for DRYSTAR 5503, 5500, AXYS, 5302 and 5300
DT2B (blue base) and DT2C (Clear base) in all media sizes
8 x 10 (20 x 25 cm), 10 x 12 (25 x 30 cm), 11 x 14 (28 x 35 cm), and 14 x 17 (35 x 43 cm)
Max. optical density >3.1 Designed to
withstand high printing power resist high temperature peaks to have good image hue even at higher printing
speed. Secure archiving up to 20 years (when stored under
proper temperature conditions)
DYSTAR 5500/5503
DYSTAR AXYS
DYSTAR 5302
DYSTAR 5300
-
19 Confidential
Media dedicated for DRYSTAR 5500, 5503 and AXYS imagers with mammography printing option Blue base Media sizes
8 x 10 (20 x 25 cm) 10 x 12 (25 x 30 cm) 11 x 14 (28 x 35 cm)
Max. optical density > 3.79 Extended term storage: minimum 20
years (when stored under proper temperature conditions)
DRYSTAR DT2 Mammo film
DYSTAR 5500/5503
DYSTAR AXYS
-
20 Confidential
Thank you