18 introduction to genex assistance

Upload: diefenbaker13

Post on 04-Jun-2018

266 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/13/2019 18 Introduction to Genex Assistance

    1/50

    Huawei TECHNOLOGIES Co., Ltd.Huawei Confidential 1

    BYMOD TY GI

    INTRODUCTION

    TO

    GENEX SSIST NCE

  • 8/13/2019 18 Introduction to Genex Assistance

    2/50

    Huawei TECHNOLOGIES Co., Ltd.Huawei Confidential2

    The GENEX Assistant is excellent software tool for

    Post-Processing 2G & 3G Drive Test Data.

    With the GENEX Assistant, you can:

    Have a panorama view of network performance

    Locate network troubles

    Improve network quality

    Verify network planning and optimization

  • 8/13/2019 18 Introduction to Genex Assistance

    3/50

    Huawei TECHNOLOGIES Co., Ltd.Huawei Confidential3

    Functions of the Genex Assistant

    Analyzing the test data in WCDMA GSM dual mode

    The Assistant analyzes the test data in the WCDMA and GSM networks

    The Assistant also has the independent display systems for separately

    displaying the engineering parameters and real-time data

    Test data playback

    The Assistant supports

    Manual or automatic play of the test dataDisplay of measurement parameters for trouble spots in detailNetwork problems locating in a quick manner

  • 8/13/2019 18 Introduction to Genex Assistance

    4/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    4

    FOR POST PROCESSING OF LOGFILE IN

    GENEX ASSISTANCE WE NEED TO

    OPEN A NEW PROJECT

    ANALYSIS OF LOGFILE

  • 8/13/2019 18 Introduction to Genex Assistance

    5/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    5

    NEW PROJECT

    STEP-1 PROJECT NAME ( TEST 01 )

    STEP-2 PROJECT PATH ( LOCATION TO SAVE THE PROJECT )

    STEP-3 MAP PATH ( Insert the Map from the Location )

    STEP-4 DATASET NAME ( LOGFILE NAME )

  • 8/13/2019 18 Introduction to Genex Assistance

    6/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    6

    Opening a New Project

  • 8/13/2019 18 Introduction to Genex Assistance

    7/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    7

    Project Path to Save It

  • 8/13/2019 18 Introduction to Genex Assistance

    8/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    8

    Log file Name

  • 8/13/2019 18 Introduction to Genex Assistance

    9/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    9

    ANALYSISLOG FILE IMPORTING

    Step 1 Select a dataset from the Project tab in the navigation

    view

    Step 2 Right-click the dataset and choose Import Test Data

    Import GENEX Probe on the shortcut menu

    Step 3 In the Import GENEX Probe log File as shown below

  • 8/13/2019 18 Introduction to Genex Assistance

    10/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    10

    Import the Type of Log File

  • 8/13/2019 18 Introduction to Genex Assistance

    11/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    11

    CLICK BROWSE FOR

    LOGFILE LOCATION

  • 8/13/2019 18 Introduction to Genex Assistance

    12/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    12

    COMBINE DATA ANALYSIS

    ASSISTANCE CAN SUPPORT IMPORTING MORE THAN ONE LOG

    FILE AS IT COMBINES THESE DEVICES AND RE-ANALYZE THE

    EVENTS

    Step 1 Select a dataset from the Projecttab in the navigation view

    Step 2 Choose Dataset> Combine Device> Combine UE

    Step 3 Select multiple devices from PreCombinein the displayed

    Combine Device

  • 8/13/2019 18 Introduction to Genex Assistance

    13/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    13

  • 8/13/2019 18 Introduction to Genex Assistance

    14/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    14

    New Combined Log file

  • 8/13/2019 18 Introduction to Genex Assistance

    15/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    15

  • 8/13/2019 18 Introduction to Genex Assistance

    16/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    16

    IMPORTING THE MAP DATA

    VECTOR

    PLACES

    CLUTTER

    Step 1 Select the Map Layer Window and right click.

    Step 2 Select the location for the data to import.

  • 8/13/2019 18 Introduction to Genex Assistance

    17/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    17

    Layer Control

  • 8/13/2019 18 Introduction to Genex Assistance

    18/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    18

    Filtering Test Data

    The Assistant can filter the imported data. This feature is capable of

    comparing the data and executing some simple logical calculations.

    To filter test data, perform the following steps:

    Step 1 Select a dataset from the Project tab in the navigation view.

    Step 2 Choose Dataset > Filter Imported Data

  • 8/13/2019 18 Introduction to Genex Assistance

    19/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    19

  • 8/13/2019 18 Introduction to Genex Assistance

    20/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    20

    Select the Desired Filter

    Click on Insert

    Click on Excute

  • 8/13/2019 18 Introduction to Genex Assistance

    21/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    21

    Introduction to Engineering Parameters

    Engineering parameter fields

    Field RemarksWhether Mandatory to BeFilled In

    Longitude Longitude (decimal) YesLatitude Latitude (decimal) Yes

    Azimuth Azimuth (C) No

    Down Tilt Down tilt angle (C) No

    E-Down Tilt Embedded down tilt angle (C) No

    M-Down Tilt Mechanical down tilt angle (C) No

    Ground Height Antenna ground height No

    Altitude Antenna altitude No

  • 8/13/2019 18 Introduction to Genex Assistance

    22/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    22

    Perform the following steps to import Engineering Parameters

    Step 1 Select a dataset from the Projecttab in the navigation view.

    Step 2 Choose Dataset> Import Engineering Parameter, andselect WCDMAor GSMbased on the test data.

    Step 3 In the displayed dialog box, perform the following operations

    Open the Excel file for saving the engineering parameters.

    Select the sheet for displaying the engineering parameters.

    Step 4 Click OK.

  • 8/13/2019 18 Introduction to Genex Assistance

    23/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    23

    If all the fields in the sheet can match the parameters

    the Assistant automatically imports the engineering parameters

    If no field in the sheet can match the parameters

    Step 5 Match the missing engineering parameter fields one by one.

    For details, refer to description of button functions

    Step 6 Click the button to import the data.After the data is imported, the site data is automatically

    displayed on the map.

  • 8/13/2019 18 Introduction to Genex Assistance

    24/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    24

    Step:01 Click on Dataset Name

    Step:02

    Select Type

  • 8/13/2019 18 Introduction to Genex Assistance

    25/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    25

    Step:03 Open the Table

    Step:04 Import the Excel file

  • 8/13/2019 18 Introduction to Genex Assistance

    26/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    26

    Engineering Parameters DisplayEngineering Parameters Display

  • 8/13/2019 18 Introduction to Genex Assistance

    27/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    27

    STEPS TO OPERATE ASSISTANT

    3. Consolidated log file for

    Different test

    4. Analyze Report

    5. Display Report on map

  • 8/13/2019 18 Introduction to Genex Assistance

    28/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    28

    STEPS TO OPERATE ASSISTANT

    6. Show Legends

    7. Show vectors (layer control)

  • 8/13/2019 18 Introduction to Genex Assistance

    29/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    29

    STEPS TO OPERATE ASSISTANT

    8. Export Tab file

  • 8/13/2019 18 Introduction to Genex Assistance

    30/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    30

    DRIVE TEST PLOTS

    RX LEVEL PLOT

    RXLEVEL FULL

    RXLEVEL SUB

  • 8/13/2019 18 Introduction to Genex Assistance

    31/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    31

  • 8/13/2019 18 Introduction to Genex Assistance

    32/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    32

    RX QUALITY PLOT

    RX QUAL FULL

    RX QUAL SUB

  • 8/13/2019 18 Introduction to Genex Assistance

    33/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    33

  • 8/13/2019 18 Introduction to Genex Assistance

    34/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    34

    OTHER DIFFERENT TYPEOF PLOTS

  • 8/13/2019 18 Introduction to Genex Assistance

    35/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    35BCCH PLOT

  • 8/13/2019 18 Introduction to Genex Assistance

    36/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    36BSIC PLOT

  • 8/13/2019 18 Introduction to Genex Assistance

    37/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    37FER PLOT

  • 8/13/2019 18 Introduction to Genex Assistance

    38/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    38C/I PLOT

  • 8/13/2019 18 Introduction to Genex Assistance

    39/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    39HANDOVER PLOT

  • 8/13/2019 18 Introduction to Genex Assistance

    40/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    40

    GSM DRIVE TEST STATISTICS

    GENEX ASSISTANCE CAN PROVIDE THE DETAIL

    REPORT OF THE DRIVE TEST

    Report: WCDMA Scanner Neighbor Cell

    Report: WCDMA Scanner Handover Statistic

    Report: WCDMA UE Call Setup

    Report: WCDMA UE Call Statistics

  • 8/13/2019 18 Introduction to Genex Assistance

    41/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    41

    Report: WCDMA UE Call Timing Analysis

    Report: WCDMA UE Crossingtable HSDPA

    Report: WCDMA UE RRC Setup Statistics

    Report: GSM Drive Test Statistics

    Report: GSM UE Call Statistics Analyse

    Report: GSMHandover Statistic

  • 8/13/2019 18 Introduction to Genex Assistance

    42/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    42

  • 8/13/2019 18 Introduction to Genex Assistance

    43/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    43

    GSM DRIVE TESTSTATISTICS

    The GSM Drive Test Statisticsreport provides the statistics on RXlevel,

    voice quality, and so on, as listed in Table

    Item Description

    RxLev RX level in connected state

    BCCH RxLev RX level in connected or idle state

    RxLev as Distance Distance values for RX level > 90 dBm and RX level < 90 dBm

    RxQual Statistics on quality and distance

    TA Number of data points in each TA scope

    Call Setup Time Number of data points in each scope of call setup duration as per call

  • 8/13/2019 18 Introduction to Genex Assistance

    44/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    44

    RxLev_Sub(dBm) Distance(km) %Total

    CountAvg

    -70 to -10 10.90 60.22 % 3152 -59.30

    -80 to -70 5.55 30.66 % 1861 -75.06

    -90 to -80 1.52 8.40 % 548 -83.48

    -100 to -90 0.11 0.61 % 33 -92.67-120 to -100 0.03 0.17 % 12 -101.00

    Total 18.10 5606 -67.18

    RxLev_Sub(dBm)

  • 8/13/2019 18 Introduction to Genex Assistance

    45/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    45

    RxQual sub Count % Distance(km) %

    7 153 2.73 % 0.79 4.35 %

    6 146 2.60 % 0.60 3.33 %

    5 143 2.55 % 0.62 3.45 %

    4 157 2.80 % 0.62 3.40 %

    3 192 3.42 % 0.92 5.11 %

    2 121 2.16 % 0.47 2.61 %

    1 203 3.62 % 0.72 3.99 %

    0 4491 80.11 % 13.35 73.77 %

    Total 5606 18.10

    RxQual_Sub

  • 8/13/2019 18 Introduction to Genex Assistance

    46/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    46

    TA Count %

    32 to 63 0 0.00 %

    10 to 32 0 0.00 %

    5 to 10 0 0.00 %

    4 to 5 0 0.00 %

    3 to 4 5 0.09 %

    2 to 3 41 0.74 %

    1 to 2 688 12.47 %

    0 to 1 4785 86.70 %

    Average 0.14

    Number of data points in each TA Scope

  • 8/13/2019 18 Introduction to Genex Assistance

    47/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    47

    Call Setup Time (Alerting - ChannelReq )

    Time Count % Avg

    0s

  • 8/13/2019 18 Introduction to Genex Assistance

    48/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    48

    RxQualCall Setup Time

    TA

    RxLev_Sub + RxLev_Idle(dBm)

    REPORTS IN DEATAIL

  • 8/13/2019 18 Introduction to Genex Assistance

    49/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    49

    GSM MS Call Analysis

    GSM MS Call Statistics

    GSM MOS Statistics

    REPORTS IN DEATAIL

  • 8/13/2019 18 Introduction to Genex Assistance

    50/50

    Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

    TH NK YOU