1.2 ajm series
TRANSCRIPT
AJMSERIES
048
AJM Series
Applications
Introduction
Iron core AJM series linear motors provide compact size, high force density, and quick response.
Iron core technology and low cogging force
High continuous and peak force
Optional hall sensors
High motor constant
Best suited for point-to-point motion with micron level positioning ; unlimited travel stroke
with top speed of 5m/s or faster (stroke of 100m or longer).
Applications & Industries: high speed positioning systems for product handling in semicon-
ductor, photovoltaic and lithium battery, glass and LCD applications, as well as industrial
printing machines, laser processing machines with demanding precision and motion control
requirements.
Series
AJM30-B2
AJM30-B4
AJM50-B2
AJM50-B4
AJM80-B2
AJM80-B4
AJM100-B2
AJM100-B4
Coil Length(mm)
96
176
96
176
96
176
96
176
100 150 200 250 300 400 500 ....
34.
3
50
75
34.
3
100
34.
3 3
4.3
125
Continuous Force (Fcn) / PeakForce (Fpk) Unit: N
Fcn (Continuous force) = 68.1N ~ 446.8N
Fpk (Peak force) = 214.7N ~ 1409.1N
1
1 No hall sensor.
Features
68.1 / 214.7
136.2 / 429.4
117.0 / 369.0
234.0 / 738.1
174.5 / 550.2
348.9 / 1100.4
223.4 / 704.5
446.8 / 1409.1
Ironless technology
Low cogging force
Integrated with hall sensors
High force and stiffness
AJM SeriesAJM30-B2
AJM30-B4 AJM50-B2
050
100150200250
0 2 4 6 8 10 12 14
Forc
e(N)
Speed (m/s)
Force Speed Curve AJM30-B2DC Bus Voltage: 310V
Conutious Force Peak Force
050
100150200250
0 5 10 15 20 25
Forc
e(N)
Speed (m/s)
Force Speed Curve AJM30-B2DC Bus Voltage: 600V
Conutious Force Peak Force
Force-Speed Curve
0100200300400500
0 2 4 6 8 10 12 14
Forc
e(N)
Speed (m/s)
Force Speed Curve AJM30-B4DC Bus Voltage: 310V
Continuous Force Peak Force
0100200300400500
0 5 10 15 20 25
Forc
e(N)
Speed (m/s)
Force Speed Curve AJM30-B4DC Bus Voltage: 600V
Continuous Force Peak Force
Dimension
Dimension
Force-Speed Curve
Dimension
Force-Speed Curve
050
100150200250300350400
0 2 4 6 8
Forc
e(N)
Speed (m/s)
Force Speed Curve AJM50-B2DC Bus Voltage: 310V
Continuous Force Peak Force
080
160240320400
0 5 10 15
Forc
e(N)
Speed (m/s)
Force Speed Curve AJM50-B2DC Bus Voltage: 600V
Continuous Force Peak Force
" TL "
20.0 Pitch
50.0
41.0
7.5 Ă 2.5"H" Ă 4.3 THRU
Stainless Steel Cover
10.3
6.0
(33.
4)
(Optional: Epoxy Cover)
40.0
For epoxy cover option, changeâ -S â to â -E â. (e.g. AJM30-TL80-E)
Magnet TrackP / N:
Track LengthâTLâ
No.of HolesâHâ
4200.080.0
1020400.0
AJM30-TL80-SAJM30-TL200-SAJM30-TL400-S
AJM30 Track AJM30-B2
UnitPerformance Parameters
Mechanical Parameters
Other Information
Continuous Force (NC) @100°CPeak ForceForce Constant ±10%Back EMF Constant ±10%Motor Constant @25°C
Electrical Time ConstantContinuous Current (NC) @100°CPeak CurrentContinuous Power Dissipation (NC) @100°CMax. Coil TemperatureThermal Dissipation Constant (NC)Max. Bus VoltageMagnetic PeriodAttraction Force
Coil Mass (NC)
Track Mass Per Meter
Insulation ClassProtection Grade
Ambient Temperature
Ambient Humidity
Recommended Ambience
Coil Length (NC)
Resistance (L-L) 25°C ±10%Inductance (L-L) ±30%
Compliance with Global Standards
NN
N/ArmsVpeak/(m/s)N/Sqrt(W)
ΩmHms
ArmsArms
Wâ
W/âVdcmmN
SymbolFcn
Fpk
Kf
Ke
Km
R25
Ïe
Icn
Ipk
Pcn
tmax
Kthn
Ubus
ÏNN
Fa
L
mcn
Lcn
mtrack
kg
kg/mmm
OperationStorageOperationStorage
Class B (130ÂșC) IP00
Chinese RoHS, CE0ÂșC to 40ÂșC (non-freezing)
-15ÂșC to 70ÂșC (non-freezing)10%RH to 80%RH (non-condensing)10%RH to 90%RH (non-condensing)
Indoor (no direct sunlight);No corrosive gas, inflammable gas, oil mist or dust.
Series68.1
214.729.624.212.2
3.916.5
4.22.39.0
40.11000.5
60020
378
0.696
3.3
1
2
3
Measurement is taken at ambient temperature 25ÂșC. Value depends on the thermal environment. Abbreviations:NC-Natural Cooling.Resistance is measured by DC current with standard 0.5 m cable.
Inductance is measured by current frequency of 1 kHz.The contents of datasheet are subject to change without prior notice.
2
3
1
1
1
1
AJM30-B4UnitPerformance Parameters
Mechanical Parameters
Other Information
Continuous Force (NC) @100°CPeak ForceForce Constant ±10%Back EMF Constant ±10%Motor Constant @25°C
Electrical Time ConstantContinuous Current (NC) @100°CPeak CurrentContinuous Power Dissipation (NC) @100°CMax. Coil TemperatureThermal Dissipation Constant (NC)Max. Bus VoltageMagnetic PeriodAttraction Force
Coil Mass (NC)
Track Mass Per Meter
Insulation ClassProtection Grade
Ambient Temperature
Ambient Humidity
Recommended Ambience
Coil Length (NC)
Resistance (L-L) 25°C ±10%Inductance (L-L) ±30%
Compliance with Global Standards
NN
N/ArmsVpeak/(m/s)N/Sqrt(W)
ΩmHms
ArmsArms
Wâ
W/âVdcmmN
SymbolFcn
Fpk
Kf
Ke
Km
R25
Ïe
Icn
Ipk
Pcn
tmax
Kthn
Ubus
ÏNN
Fa
L
mcn
Lcn
mtrack
kg
kg/mmm
OperationStorageOperationStorage
Class B (130ÂșC) IP00
Chinese RoHS, CE0ÂșC to 40ÂșC (non-freezing)
-15ÂșC to 70ÂșC (non-freezing)10%RH to 80%RH (non-condensing)10%RH to 90%RH (non-condensing)
Indoor (no direct sunlight);No corrosive gas, inflammable gas, oil mist or dust.
1
2
3
Measurement is taken at ambient temperature 25ÂșC. Value depends on the thermal environment. Abbreviations:NC-Natural Cooling.Resistance is measured by DC current with standard 0.5 m cable.
Inductance is measured by current frequency of 1 kHz.The contents of datasheet are subject to change without prior notice.
2
3
1
1
1
1
Parallel136.2429.4
29.624.217.0
2.08.24.14.6
18.082.61001.1
60020
756
1.11763.3
IntroductionSizing Guide
Frequently Asked Questions
Voice Coil Motors
Direct Drive Rotary Motors
Motion Control of Gantry Stages
Linear Motors
AJM50-B2UnitPerformance Parameters
Mechanical Parameters
Other Information
Continuous Force (NC) @100°CPeak ForceForce Constant ±10%Back EMF Constant ±10%Motor Constant @25°C
Electrical Time ConstantContinuous Current (NC) @100°CPeak CurrentContinuous Power Dissipation (NC) @100°CMax. Coil TemperatureThermal Dissipation Constant (NC)Max. Bus VoltageMagnetic PeriodAttraction Force
Coil Mass (NC)
Track Mass Per Meter
Insulation ClassProtection Grade
Ambient Temperature
Ambient Humidity
Recommended Ambience
Coil Length (NC)
Resistance (L-L) 25°C ±10%Inductance (L-L) ±30%
Compliance with Global Standards
NN
N/ArmsVpeak/(m/s)N/Sqrt(W)
ΩmHms
ArmsArms
Wâ
W/âVdcmmN
SymbolFcn
Fpk
Kf
Ke
Km
R25
Ïe
Icn
Ipk
Pcn
tmax
Kthn
Ubus
ÏNN
Fa
L
mcn
Lcn
mtrack
kg
kg/mmm
OperationStorageOperationStorage
Class B (130ÂșC) IP00
Chinese RoHS, CE0ÂșC to 40ÂșC (non-freezing)
-15ÂșC to 70ÂșC (non-freezing)10%RH to 80%RH (non-condensing)10%RH to 90%RH (non-condensing)
Indoor (no direct sunlight);No corrosive gas, inflammable gas, oil mist or dust.
1
2
3
Measurement is taken at ambient temperature 25ÂșC. Value depends on the thermal environment. Abbreviations:NC-Natural Cooling.Resistance is measured by DC current with standard 0.5 m cable.
Inductance is measured by current frequency of 1 kHz.The contents of datasheet are subject to change without prior notice.
2
3
1
1
1
1
Series117.0369.0
50.941.517.0
6.025.9
4.32.39.0
61.21000.8
60020
650
0.996
5.0
AJM Series
Intr
oduc
tion
Sizi
ng G
uide
Freq
uent
ly A
sked
Que
stio
nsVo
ice
Coil
Mot
ors
Dire
ct D
rive
Rota
ry M
otor
sM
otio
n Co
ntro
l of G
antr
y St
ages
Line
ar M
otor
s
8ĂM3 3.5
0.0
12.0
36.0
60.0
84.0
96.0
0.0
15.0
35.0
50.0
Hall Cable 3.8
Motor Cable 7.4Min.Bending Radius=74.0
Hall Module
0.0
10.3
11.1
21.9
27.3
32.3
34.3
0.05.09.0
20.0
41.050.0
0.0
50.0
0.0
96.0
120.
0
0.0
23.2
Motor Track
0.0
15.0
35.0
50.0
0.0
12.0
36.0
60.0
116.
0
140.
0
164.
017
6.0
Hall Cable 3.8
Hall Module
0.0
10.3
11.1
34.3
27.3
21.9
0.0
50.0
5.0 0.0
50.0
20.0
32.3
9.0
41.0
0.0
176.
0
200.
0
0.0
23.2
Motor Track
12ĂM3 3.5
Motor Cable 7.4Min.Bending Radius=74.0
0.0
12.0
36.0
60.0
84.0
96.0
0.0
17.5
37.5
57.5
75.0 Hall Module
Hall Cable 3.8
0.0
10.3
11.1
21.9
27.3
32.3
34.3
0.05.0
10.0
44.0
65.075.0
0.0
75.0
0.0
96.0
120.
0
0.0
23.2
Motor Track
Motor Cable 7.4Min.Bending Radius=74.0
12ĂM3 3.5
049 050
AJM50-B4 AJM80-B2
AJM80-B4
Dimension
Force-Speed Curve
Dimension
Force-Speed Curve
Dimension
Force-Speed Curve
0150300450600750900
0 2 4 6 8
Forc
e(N)
Speed (m/s)
Force Speed Curve AJM50-B4DC Bus Voltage: 310V
Continuous Force Peak Force
0150300450600750900
0 3 6 9 12 15
Forc
e(N)
Speed (m/s)
Force Speed Curve AJM50-B4DC Bus Voltage: 600V
Continuous Force Peak Force
0100200300400500600
0 1 2 3 4 5 6
Forc
e(N)
Speed (m/s)
Force Speed Curve AJM80-B2DC Bus Voltage: 310V
Continuous Force Peak Force
0100200300400500600
0 2 4 6 8 10
Forc
e(N)
Speed (m/s)
Force Speed Curve AJM80-B2DC Bus Voltage: 600V
Continuous Force Peak Force
0200400600800
10001200
0 1 2 3 4 5 6
Forc
e(N)
Speed (m/s)
Force Speed Curve AJM80-B4DC Bus Voltage: 310V
Continuous Force Peak Force
0200400600800
10001200
0 2 4 6 8 10
Forc
e(N)
Speed(m/s)
Force Speed Curve AJM80-B4DC Bus Voltage: 600V
Continuous Force Peak Force
For epoxy cover option, changeâ -S â to â -E â. (e.g. AJM50-TL80-E)
Magnet TrackP / N:
Track LengthâTLâ
No.of HolesâHâ
4200.080.0
1020400.0
AJM50-TL80-SAJM50-TL200-SAJM50-TL400-S
AJM50 Track
75.0
20.0 Pitch
" TL "
65.0
"H" Ă 4.3THRU7.5 Ă 2.5
Stainless Steel Cover
6.0
10.3(5
6.4)
(Optional: Epoxy Cover)
40.0
052051
AJM50-B4UnitPerformance Parameters
Mechanical Parameters
Other Information
Continuous Force (NC) @100°CPeak ForceForce Constant ±10%Back EMF Constant ±10%Motor Constant @25°C
Electrical Time ConstantContinuous Current (NC) @100°CPeak CurrentContinuous Power Dissipation (NC) @100°CMax. Coil TemperatureThermal Dissipation Constant (NC)Max. Bus VoltageMagnetic PeriodAttraction Force
Coil Mass (NC)
Track Mass Per Meter
Insulation ClassProtection Grade
Ambient Temperature
Ambient Humidity
Recommended Ambience
Coil Length (NC)
Resistance (L-L) 25°C ±10%Inductance (L-L) ±30%
Compliance with Global Standards
NN
N/ArmsVpeak/(m/s)N/Sqrt(W)
ΩmHms
ArmsArms
Wâ
W/âVdcmmN
SymbolFcn
Fpk
Kf
Ke
Km
R25
Ïe
Icn
Ipk
Pcn
tmax
Kthn
Ubus
ÏNN
Fa
L
mcn
Lcn
mtrack
kg
kg/mmm
OperationStorageOperationStorage
Class B (130ÂșC) IP00
Chinese RoHS, CE0ÂșC to 40ÂșC (non-freezing)
-15ÂșC to 70ÂșC (non-freezing)10%RH to 80%RH (non-condensing)10%RH to 90%RH (non-condensing)
Indoor (no direct sunlight);No corrosive gas, inflammable gas, oil mist or dust.
1
2
3
Measurement is taken at ambient temperature 25ÂșC. Value depends on the thermal environment. Abbreviations:NC-Natural Cooling.Resistance is measured by DC current with standard 0.5 m cable.
Inductance is measured by current frequency of 1 kHz.The contents of datasheet are subject to change without prior notice.
2
3
1
1
1
1
Parallel234.0738.1
50.941.523.8
3.113.0
4.24.6
18.0124.8
1001.7
60020
1299
1.71765.0
AJM80-B2UnitPerformance Parameters
Mechanical Parameters
Other Information
Continuous Force (NC) @100°CPeak ForceForce Constant ±10%Back EMF Constant ±10%Motor Constant @25°C
Electrical Time ConstantContinuous Current (NC) @100°CPeak CurrentContinuous Power Dissipation (NC) @100°CMax. Coil TemperatureThermal Dissipation Constant (NC)Max. Bus VoltageMagnetic PeriodAttraction Force
Coil Mass (NC)
Track Mass Per Meter
Insulation ClassProtection Grade
Ambient Temperature
Ambient Humidity
Recommended Ambience
Coil Length (NC)
Resistance (L-L) 25°C ±10%Inductance (L-L) ±30%
Compliance with Global Standards
NN
N/ArmsVpeak/(m/s)N/Sqrt(W)
ΩmHms
ArmsArms
Wâ
W/âVdcmmN
SymbolFcn
Fpk
Kf
Ke
Km
R25
Ïe
Icn
Ipk
Pcn
tmax
Kthn
Ubus
ÏNN
Fa
L
mcn
Lcn
mtrack
kg
kg/mmm
OperationStorageOperationStorage
Class B (130ÂșC) IP00
Chinese RoHS, CE0ÂșC to 40ÂșC (non-freezing)
-15ÂșC to 70ÂșC (non-freezing)10%RH to 80%RH (non-condensing)10%RH to 90%RH (non-condensing)
Indoor (no direct sunlight);No corrosive gas, inflammable gas, oil mist or dust.
1
2
3
Measurement is taken at ambient temperature 25ÂșC. Value depends on the thermal environment. Abbreviations:NC-Natural Cooling.Resistance is measured by DC current with standard 0.5 m cable.
Inductance is measured by current frequency of 1 kHz.The contents of datasheet are subject to change without prior notice.
2
3
1
1
1
1
Series174.5550.2
75.961.921.4
8.437.3
4.52.39.0
85.51001.1
60020
969
1.296
7.0
AJM80-B4UnitPerformance Parameters
Mechanical Parameters
Other Information
Continuous Force (NC) @100°CPeak ForceForce Constant ±10%Back EMF Constant ±10%Motor Constant @25°C
Electrical Time ConstantContinuous Current (NC) @100°CPeak CurrentContinuous Power Dissipation (NC) @100°CMax. Coil TemperatureThermal Dissipation Constant (NC)Max. Bus VoltageMagnetic PeriodAttraction Force
Coil Mass (NC)
Track Mass Per Meter
Insulation ClassProtection Grade
Ambient Temperature
Ambient Humidity
Recommended Ambience
Coil Length (NC)
Resistance (L-L) 25°C ±10%Inductance (L-L) ±30%
Compliance with Global Standards
NN
N/ArmsVpeak/(m/s)N/Sqrt(W)
ΩmHms
ArmsArms
Wâ
W/âVdcmmN
SymbolFcn
Fpk
Kf
Ke
Km
R25
Ïe
Icn
Ipk
Pcn
tmax
Kthn
Ubus
ÏNN
Fa
L
mcn
Lcn
mtrack
kg
kg/mmm
OperationStorageOperationStorage
Class B (130ÂșC) IP00
Chinese RoHS, CE0ÂșC to 40ÂșC (non-freezing)
-15ÂșC to 70ÂșC (non-freezing)10%RH to 80%RH (non-condensing)10%RH to 90%RH (non-condensing)
Indoor (no direct sunlight);No corrosive gas, inflammable gas, oil mist or dust.
1
2
3
Measurement is taken at ambient temperature 25ÂșC. Value depends on the thermal environment. Abbreviations:NC-Natural Cooling.Resistance is measured by DC current with standard 0.5 m cable.
Inductance is measured by current frequency of 1 kHz.The contents of datasheet are subject to change without prior notice.
2
3
1
1
1
1
Parallel348.9
1100.475.961.930.1
4.218.6
4.44.6
18.0173.5
1002.3
60020
1937
2.31767.0
AJM Series AJM Series
IntroductionSizing Guide
Frequently Asked Questions
Voice Coil Motors
Direct Drive Rotary Motors
Motion Control of Gantry Stages
Linear Motors
Intr
oduc
tion
Sizi
ng G
uide
Freq
uent
ly A
sked
Que
stio
nsVo
ice
Coil
Mot
ors
Dire
ct D
rive
Rota
ry M
otor
sM
otio
n Co
ntro
l of G
antr
y St
ages
Line
ar M
otor
s
0.0
17.5
37.5
57.5
75.0
0.0
12.0
36.0
60.0
116.
0
140.
0
164.
017
6.0
Hall Cable 3.8
Hall Module
0.0
10.3
11.1
21.9
27.3
34.3
32.3
0.0
75.0
0.0
75.0
5.0
44.0
10.0
65.0
0.0
176.
0
200.
0
0.0
23.2
0 Motor Track
Motor Cable 7.4Min.Bending Radius=74.0
18ĂM3 3.5
0.0
12.0
36.0
60.0
84.0
96.0
0.0
20.0
40.0
60.0
80.0
100.0
Hall Module
Hall Cable 3.8
0.0
10.3
11.1
21.9
27.3
34.3
32.3
0.05.09.0
69.0
91.0100.0
0.0
100.0
0.0
96.0
120.
0
0.0
23.2
Motor Track
16ĂM3 3.5
Motor Cable 7.4Min.Bending Radius=74.0
0.0
12.0
36.0
60.0
116.
0
140.
0
164.
017
6.0
0.0
20.0
40.0
60.0
80.0
100.0
Hall Cable 3.8
Hall Module
0.0
10.3
11.1
21.9
34.3
32.3
27.3
0.0
100.0
0.05.0
100.0
69.0
9.0
91.0
0.0
176.
0
200.
0
0.0
23.2
Motor Track
12ĂM3 3.5
Motor Cable 7.4Min.Bending Radius=74.0
AJM100-B4
AJM100-B2Dimension
Force-Speed Curve
Dimension
Force-Speed Curve
0150300450600750
0 1 2 3 4
Forc
e(N)
Speed (m/s)
Force Speed Curve AJM100-B2DC Bus Voltage: 310V
Continuous Force Peak Force
0100200300400500600700800
0 2 4 6 8
Forc
e(N)
Speed (m/s)
Force Speed Curve AJM100-B2DC Bus Voltage: 600V
Continuous Force Peak Force
0250500750
100012501500
0 1 2 3 4
Forc
e(N)
Speed (m/s)
Force Speed Curve AJM100-B4DC Bus Voltage: 310V
Continuous Force Peak Force
0250500750
100012501500
0 2 4 6 8
Forc
e(N)
Speed (m/s)
Force Speed Curve AJM100-B4DC Bus Voltage: 600V
Continuous Force Peak ForceFor epoxy cover option, changeâ -S â to â -E â. (e.g. AJM80-TL80-E)
Magnet TrackP / N:
Track LengthâTLâ
No.of HolesâHâ
4200.080.0
1020400.0
AJM80-TL80-SAJM80-TL200-SAJM80-TL400-S
For epoxy cover option, changeâ -S â to â -E â. (e.g. AJM100-TL80-E)
Magnet TrackP / N:
Track LengthâTLâ
No.of HolesâHâ
4200.080.0
1020400.0
AJM100-TL80-SAJM100-TL200-SAJM100-TL400-S
AJM80 Track
100.
0
91.0
20.0 Pitch
"H" Ă 4.3
THRU7.5 Ă 2.5
" TL "
Stainless Steel Cover
6.0
10.3
(83.
4)
(Optional: Epoxy Cover)
40.0
AJM100 Track
125.
0
115.
0
20.0 Pitch
" TL "
"H" Ă 4.3 THRU7.5 Ă 2.5
Stainless Steel Cover
6.0
10.3
(106
.4)
(Optional: Epoxy Cover)
40.0
054053
AJM100-B2UnitPerformance Parameters
Mechanical Parameters
Other Information
Continuous Force (NC) @100°CPeak ForceForce Constant ±10%Back EMF Constant ±10%Motor Constant @25°C
Electrical Time ConstantContinuous Current (NC) @100°CPeak CurrentContinuous Power Dissipation (NC) @100°CMax. Coil TemperatureThermal Dissipation Constant (NC)Max. Bus VoltageMagnetic PeriodAttraction Force
Coil Mass (NC)
Track Mass Per Meter
Insulation ClassProtection Grade
Ambient Temperature
Ambient Humidity
Recommended Ambience
Coil Length (NC)
Resistance (L-L) 25°C ±10%Inductance (L-L) ±30%
Compliance with Global Standards
NN
N/ArmsVpeak/(m/s)N/Sqrt(W)
ΩmHms
ArmsArms
Wâ
W/âVdcmmN
SymbolFcn
Fpk
Kf
Ke
Km
R25
Ïe
Icn
Ipk
Pcn
tmax
Kthn
Ubus
ÏNN
Fa
L
mcn
Lcn
mtrack
kg
kg/mmm
OperationStorageOperationStorage
Class B (130ÂșC) IP00
Chinese RoHS, CE0ÂșC to 40ÂșC (non-freezing)
-15ÂșC to 70ÂșC (non-freezing)10%RH to 80%RH (non-condensing)10%RH to 90%RH (non-condensing)
Indoor (no direct sunlight);No corrosive gas, inflammable gas, oil mist or dust.
1
2
3
Measurement is taken at ambient temperature 25ÂșC. Value depends on the thermal environment. Abbreviations:NC-Natural Cooling.Resistance is measured by DC current with standard 0.5 m cable.
Inductance is measured by current frequency of 1 kHz.The contents of datasheet are subject to change without prior notice.
2
3
1
1
1
1
Series223.4704.5
97.179.324.710.347.2
4.62.39.0
105.31001.4
60020
1240
1.596
8.8
AJM100-B4UnitPerformance Parameters
Mechanical Parameters
Other Information
Continuous Force (NC) @100°CPeak ForceForce Constant ±10%Back EMF Constant ±10%Motor Constant @25°C
Electrical Time ConstantContinuous Current (NC) @100°CPeak CurrentContinuous Power Dissipation (NC) @100°CMax. Coil TemperatureThermal Dissipation Constant (NC)Max. Bus VoltageMagnetic PeriodAttraction Force
Coil Mass (NC)
Track Mass Per Meter
Insulation ClassProtection Grade
Ambient Temperature
Ambient Humidity
Recommended Ambience
Coil Length (NC)
Resistance (L-L) 25°C ±10%Inductance (L-L) ±30%
Compliance with Global Standards
NN
N/ArmsVpeak/(m/s)N/Sqrt(W)
ΩmHms
ArmsArms
Wâ
W/âVdcmmN
SymbolFcn
Fpk
Kf
Ke
Km
R25
Ïe
Icn
Ipk
Pcn
tmax
Kthn
Ubus
ÏNN
Fa
L
mcn
Lcn
mtrack
kg
kg/mmm
OperationStorageOperationStorage
Class B (130ÂșC) IP00
Chinese RoHS, CE0ÂșC to 40ÂșC (non-freezing)
-15ÂșC to 70ÂșC (non-freezing)10%RH to 80%RH (non-condensing)10%RH to 90%RH (non-condensing)
Indoor (no direct sunlight);No corrosive gas, inflammable gas, oil mist or dust.
1
2
3
Measurement is taken at ambient temperature 25ÂșC. Value depends on the thermal environment. Abbreviations:NC-Natural Cooling.Resistance is measured by DC current with standard 0.5 m cable.
Inductance is measured by current frequency of 1 kHz.The contents of datasheet are subject to change without prior notice.
2
3
1
1
1
1
Parallel446.8
1409.197.179.334.8
5.223.6
4.54.6
18.0213.0
1002.8
60020
2481
2.91768.8
AJM Series AJM Series
IntroductionSizing Guide
Frequently Asked Questions
Voice Coil Motors
Direct Drive Rotary Motors
Motion Control of Gantry Stages
Linear Motors
Intr
oduc
tion
Sizi
ng G
uide
Freq
uent
ly A
sked
Que
stio
nsVo
ice
Coil
Mot
ors
Dire
ct D
rive
Rota
ry M
otor
sM
otio
n Co
ntro
l of G
antr
y St
ages
Line
ar M
otor
s
0.0
12.0
36.0
60.0
84.0
96.0
0.0
22.5
42.5
62.5
82.5
102.5
125.0
Hall Module
Hall Cable 3.8
0.0
10.3
11.1
21.9
27.3
34.3
32.3
0.05.0
10.0
94.0
115.0125.0
0.0
125.0
0.0
96.0
120.
0
0.0
23.2
Motor Track
20ĂM3 3.5
Motor Cable 7.4Min.Bending Radius=74.0
0.0
12.0
36.0
60.0
116.
0
140.
0
164.
017
6.0
0.0
22.5
42.5
62.5
82.5
102.5
125.0
Hall Cable 3.8
Hall Module
0.0
10.3
11.1
21.9
34.3
32.3
27.3
0.0
125.0
0.05.0
125.0
94.0
10.0
115.0
0.0
176.
0
200.
0
0.0
23.2
Motor Track
30ĂM3 3.5
Motor Cable 7.4Min.Bending Radius=74.0
Part NumberingMotor Cable Connection
Motor Coil
Motor Track
Size:
AJM30 / AJM50 / AJM80 / AJM100Model:
NFB = No ferrite bead3FB = Ferrite bead4
1 NH =Without Built-in Hall Sensor cable2 HF = With Built-in hall sensor & hall cable comes with flying leads (Standard)
B2 / B4
Motor Cable Option:NFB / FB
Cable Length(m):0.5 / 3.0
(Contact us for other lengths)
Hall Cable Option:NH / HF
AJM30-B2-J-NH-0.5-NFB
Thermal Sensor:J=Thermostat(standard) / K=PT100(RTD)(Contact us for other thermal sensorïŒ
AJM30-TL200-S
AJM30 / AJM50 / AJM80 / AJM100Model:
TL80 / TL200 / TL400Track Length:
Cover Type:S / E
S = Stainless steel cover56 E = Epoxy cover
056055
2
5 6
3 4
1
AJM Series AJM Series
IntroductionSizing Guide
Frequently Asked Questions
Voice Coil Motors
Direct Drive Rotary Motors
Motion Control of Gantry Stages
Linear Motors
Intr
oduc
tion
Sizi
ng G
uide
Freq
uent
ly A
sked
Que
stio
nsVo
ice
Coil
Mot
ors
Dire
ct D
rive
Rota
ry M
otor
sM
otio
n Co
ntro
l of G
antr
y St
ages
Line
ar M
otor
s
Motor Windings
Brown
White
Grey
M1
M2
M3
T1
T2
Sensor Pink
Blue
Motor Casing
Yellow/Green DrainShield
Hall SensorModule (Default)
Grey
Yellow
BlueRedBlack
Shield
0 V+5 VdcHc
Hb
Ha
MotorPowerCable
MotorHallSignalCable
HALL
Motor
T1T2
*DEFAULT FLYING LEADSOPTION-DSUB 9 PINS (MALE)
THERMAL SENSOR WIRE( K TYPE =PT100 )( J TYPE=THERMOSTAT )
M1
M3M2PE
FERRITE BEAD
SIDE VIEW
MOTOR CABLEDESCRIPTIONPIN NO FERRITE BEAD FERRITE BEAD
- M1- M2- M3- PE
BROWN BLACK1BLACK2BLACK3
WHITEGREY
YELLOW/GREENPINKBLUE
YELLOW/GREENPINKBLUE
--
T1T2
HALL CABLEDESCRIPTIONPIN COLOR
1 HA GREY2 HB YELLOW3 HC BLUE4 5VDC RED
BLACK5 0VDC