zxsdr b8200 gu360 (v4.00.100) indoor gsm&umts dual mode baseband unit ground parameter reference

51
ZXSDR B8200 GU360 Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference Version 4.00.100 ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, P. R. China 518057 Tel: (86) 755 26771900 Fax: (86) 755 26770801 URL: http://ensupport.zte.com.cn E-mail: [email protected]

Upload: musyoka-jackson-musyoka

Post on 28-Jul-2015

736 views

Category:

Documents


18 download

TRANSCRIPT

Page 1: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360Indoor GSM&UMTS Dual Mode

Baseband UnitGround Parameter Reference

Version 4.00.100

ZTE CORPORATIONZTE Plaza, Keji Road South,Hi-Tech Industrial Park,Nanshan District, Shenzhen,P. R. China518057Tel: (86) 755 26771900Fax: (86) 755 26770801URL: http://ensupport.zte.com.cnE-mail: [email protected]

Page 2: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

LEGAL INFORMATION

Copyright © 2006 ZTE CORPORATION.

The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution ofthis document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPO-RATION is prohibited. Additionally, the contents of this document are protected by contractual confidentiality obligations.

All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE CORPORATIONor of their respective owners.

This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions are dis-claimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose, title or non-in-fringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on theinformation contained herein.

ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subjectmatter of this document. Except as expressly provided in any written license between ZTE CORPORATION and its licensee,the user of this document shall not acquire any license to the subject matter herein.

ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.

Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.

The ultimate right to interpret this product resides in ZTE CORPORATION.

Revision History

Revision No. Revision Date Revision Reason

1.0 20090105 First Edition (B8200 GU360 V4.00.100b2 + OMMBV4.00.100d2)

Serial Number: 20085384

Page 3: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Contents

Preface............................................................... i

General Configuration Parameters ....................1Base Station .................................................................. 1

BS Equipment Resource Management................................ 4

Rack ............................................................................. 6

Rack Topo...................................................................... 7

Antenna ........................................................................ 9

RF Connection...............................................................10

Tower Top Amplifier .......................................................11

Environment Supervision ................................................13

Clock Source PRI ...........................................................14

Serial Port Information ...................................................15

AISG Device .................................................................16

Dry Contact ..................................................................17

Transmission Configuration Parameters..........19Physical Layer Management ............................................19

E1/T1 Link................................................................19

HDLC Link ................................................................20

Time Slot Interchange................................................22

Global Port Layer Management ........................................23

Ethernet...................................................................23

QoS Bandwidth .........................................................25

PPP Link ...................................................................26

Global Port ...............................................................30

IP/Static Router Layer Management .................................31

IP Parameter.............................................................31

Static Router.............................................................33

Transmission Layer Management .....................................34

SCTP Association .......................................................34

SCTP Stream ............................................................37

OMC-B Link ..............................................................38

Page 4: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Clock Configuration........................................................39

IP Clock ...................................................................39

Figures ............................................................41

Tables .............................................................43

List of Glossary................................................45

Page 5: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Preface

Purpose ZXWR OMM is the operation and maintenance module of ZTEWCDMA product series. Configuration management, fault man-agement, topology management, performance management andsecurity management can be performed via OMM.

This manual is a parameter reference for BS ground resource man-agement.

What is in ThisManual

TABLE 1 CHAPTER SUMMARY

Chapter Summary

Chapter 1 General ConfigurationParameters

Introduces general configurationparameters of ground resourcemanagement.

Chapter 2 TransmissionConfiguration Parameters

Introduces transmissionconfiguration parameters ofground resource management.

IntendedAudience

� Maintenance engineer

� NM engineer

Confidential and Proprietary Information of ZTE CORPORATION i

Page 6: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

This page is intentionally blank.

ii Confidential and Proprietary Information of ZTE CORPORATION

Page 7: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

C h a p t e r 1

General ConfigurationParameters

Table of ContentsBase Station ...................................................................... 1BS Equipment Resource Management.................................... 4Rack ................................................................................. 6Rack Topo.......................................................................... 7Antenna ............................................................................ 9RF Connection...................................................................10Tower Top Amplifier ...........................................................11Environment Supervision....................................................13Clock Source PRI ...............................................................14Serial Port Information .......................................................15AISG Device .....................................................................16Dry Contact ......................................................................17

Base StationInterface The related interface is shown in the figure below.

Confidential and Proprietary Information of ZTE CORPORATION 1

Page 8: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

2 Confidential and Proprietary Information of ZTE CORPORATION

Page 9: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Chapter 1 General Configuration Parameters

Parameter Parameter description is shown in the table below.

Parameter Description Value Range Remarks

User Label Self-defined name 40 characters at most -

Managed Element IDID of BS managed el-ement, for OMM use [0, 65535] -

Managed ElementType BS Type {ZTE series BS type} -

Managed Element IPAddress

IP address for BS op-eration and mainte-nance - -

Vendor Name BS manufacturer 40 characters at most -

User Defined State Reserved field - -

Confidential and Proprietary Information of ZTE CORPORATION 3

Page 10: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

Parameter Description Value Range Remarks

LocationDescription of BS in-stallation location 40 characters at most -

Software VersionBS Software VersionNo. {Software Version} -

LongitudeLongitude of BS loca-tion

[-180.00000,180.00000] -

Latitude Latitude of BS location[-90.00000,90.00000] -

Maintain StatusWhether ME is in serv-ice state {Normal, Testing}

OMM does not reportto upper-level NM sys-tem the alarm causedby BS testing status.

BS Equipment ResourceManagement

Interface The related interface is shown in the figure below.

4 Confidential and Proprietary Information of ZTE CORPORATION

Page 11: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Chapter 1 General Configuration Parameters

Parameter Parameter description is shown in the table below.

Parameter Description Value Range Remarks

User Label Self-defined name 40 characters at most -

Base Station ID [0, 65535] Inter-Operabilityparameter,consistent with RNCconfiguration

Base Station No

Base StationDescription

BS Description 200 characters atmost

-

Base Station Type BS Type - Parameter valueautomatically set bythe system

Confidential and Proprietary Information of ZTE CORPORATION 5

Page 12: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

Parameter Description Value Range Remarks

GSM No GSM No when GSMmode of the BS issupported

[0, 65535] –

Clock SyncPeriod(Hours)

SNTP clocksynchronizationperiod for the BS

[0, 48] -

Medium Type of IUBLine

Transmission mediumat Iub/Abis interface

{E1, T1, FE, Sat, GE} –

NTP Server IP Address Time server IPaddress

- -

Time Zone The time zone whereOMC-B is located

Refer to softwarepull-down list

-

Support Power-offControl

Whether power-offcontrol is supported

{Supported, NotSupported}

If the parameteris configured as“supported”, systemwill adjust theoperation of BS boardin order to savepower.

Power Work Model Working mode of thetwo power supplies

{Master And SlaveModel, BurthenPartake Model}

The current versiononly supports “MasterAnd Slave Model”.

Network Switch Model Network switch modelwhen two FS boardsare configured.

{Master And SlaveModel, BurthenPartake Model}

Transmission Type Transmission type atIub/Abis interface

{Full IP} -

Radio Mode Radio mode used bythe dual-mode BS

{GSM, WCDMA,GSM/WCDMA}

Support SummerTime

Whether summertime is supported

{Supported, NotSupported}

If the parameteris configured as“supported”, Startingand ending summertime should beconfigured.

RackInterface The related interface is shown in the figure below.

6 Confidential and Proprietary Information of ZTE CORPORATION

Page 13: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Chapter 1 General Configuration Parameters

Parameter Parameter description is shown in the table below.

Parameter Description Value Range Remarks

User Label Self-defined namefor the current MO(managed object).

40 characters at most -

Rack No. Rack No. [1, 25] Main rack No. is 1.RU/RRU rack No. is2~25.

Rack Type Rack type {Rack type} -

Rack Name User-Defined rackname

200 characters atmost

-

Phone Number Phone number - -

Rack TopoInterface The related interface is shown in the figure below.

Confidential and Proprietary Information of ZTE CORPORATION 7

Page 14: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

Parameter Parameter description is shown in the table below.

Parameter Description Value Range Remarks

User Label Self-Defined Name 40 characters at most -

Rack No. Rack No. ofupper-level NE inthe case of cascadenetworking

{The rack that can becascaded}

Shelf No. Shelf No. ofupper-level boardin the case of cascadenetworking

{The rack that can becascaded}

Slot No. Slot No. ofupper-level boardin the case of cascadenetworking

{The rack that can becascaded}

Port ID Port ID of upper-levelboard in the case ofcascade networking

Depending on boardtype

Cascading interface A

8 Confidential and Proprietary Information of ZTE CORPORATION

Page 15: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Chapter 1 General Configuration Parameters

Parameter Description Value Range Remarks

Child Rack No. Rack No. oflower-level NE inthe case of cascadenetworking

{The rack that can becascaded}

Child Shelf No. Shelf No. oflower-level boardin the case of cascadenetworking

{The rack that can becascaded}

Child Slot No. Slot No. of lower-levelboard in the case ofcascade networking

{The rack that can becascaded}

Child Port ID Port ID of lower-levelboard in the case ofcascade networking

Depending on thetype of lower-levelBS/RRU

Cascading interface B

RRU Connection Mode RRU networking mode Depending onthe networkingmode supported byRRU/BBU

-

AntennaInterface The related interface is shown in the figure below.

Parameter Parameter description is shown in the table below.

Parameter Description Value Range Remarks

User Label Self-defined name 40 characters at most -

Confidential and Proprietary Information of ZTE CORPORATION 9

Page 16: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

Parameter Description Value Range Remarks

Rack No. No. of the rack thatcan be configuredwith antenna

{The rack that hasbeen created and canbe configured withantenna}

-

Slot No. Antenna ID Depending on themaximum number ofantennas per rack

-

Antenna Type Antenna type {ANT, RET} ANT-Ordinaryantenna; RET-Remoteelectrical tilt antenna

RF ConnectionInterface The related interface is shown in the figure below.

Parameter Parameter description is shown in the table below.

10 Confidential and Proprietary Information of ZTE CORPORATION

Page 17: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Chapter 1 General Configuration Parameters

Parameter Description Value Range Remarks

User Label Self-Defind Name 40 characters at most -

RF Connection ID ID of RF connection [0, 254] -

Transceiving Flag Whether the RFconnection is transmitconnection or receiveconnection

{Uplink (Receive),Downlink (Transmit)}

-

RF Connection Type Type of RF connection Depending on BS typeand the correspondingboard type

-

Rack No. No. of the rack wherethe RF unit usedby the current RFconnection is located

- -

board (rack, shelf,slot)

ID of the RF unit(board) used by thecurrent RF connection

- -

In/Out Port ID Port ID of the RF unitused by RF connection

- In Port ID isconfigured foruplink; Out PortID is configured fordownlink.

Tower Top AmplifierInterface The related interface is shown in the figure below.

Confidential and Proprietary Information of ZTE CORPORATION 11

Page 18: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

Parameter Parameter description is shown in the table below.

Parameter Description Value Range

User Label Self-defined name 40 characters at most

Rack No./ shelf No./Tower TopAmplifier ID

Rack No./ shelf No./AntennaID of the antenna thatis connected with toweramplifier

{ID of the created antenna}

Type Type of tower top amplifier {TMA, TMB30, TMB40, ATMA,ACOM}

TMA[110, 130] x (0.1dB)

TMB30/40 [120, 240] x(0.1dB)

ATMA[44, 52] x (0.25dB)

Uplink Power Gain Uplink power gain

ACOM[0, 14] x (0.5dB)

Downlink Power Gain Downlink power gain TMB30/40[70, 170] x (0.1dB)

12 Confidential and Proprietary Information of ZTE CORPORATION

Page 19: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Chapter 1 General Configuration Parameters

Parameter Description Value Range

Tower Top Amplifier NoiseCoefficient

Noise coefficient [10, 30] x (0.1 dB)

Tower Top Amplifier FeederCable Loss

Feeder loss [0, 80] x (0.1 dB)

Minimum Power SupplyCurrent

Under-Current alarmthreshold

[0, 70]

Work Current Alarm UpperLimit

Upper limit of work currentalarm

[135, 160]

Work Current Alarm LowerLimit

Lower limit of work currentalarm

[70, 85]

Environment SupervisionInterface The related interface is shown in the figure below.

Parameter Parameter description is shown in the table below.

Confidential and Proprietary Information of ZTE CORPORATION 13

Page 20: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

Parameter Description Value Range

User Label Self-defined name 40 characters at most

Rack No.

Shelf No.

Slot No.

Location of the SA board Rack No./Shelf No./Slot No.where SA board is located

Environment MonitoringThreshold Type

Environment supervision type {External Temperature, VSWRAlarm Threshold}

Upper Limit Alarm upper limit Depending on environmentsupervision type

Lower Limit Alarm lower limit Depending on environmentsupervision type

Clock Source PRIInterface The related interface is shown in the figure below.

Parameter Parameter description is shown in the table below.

Parameter Description Value Range Remarks

User Label Self-Defined name 40 characters at most -

14 Confidential and Proprietary Information of ZTE CORPORATION

Page 21: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Chapter 1 General Configuration Parameters

Parameter Description Value Range Remarks

External Clock SourceID

Type of external clocksource

Depending onthe clock sourcesupported by BS

-

Priority Priority of clocksource

Depending on thenumber of clocksources supported byBS

Parameter value andpriority level areinversely correlated.(The lower thevalue is, the higherthe priority levelbecomes.)

Serial Port InformationInterface The related interface is shown in the figure below.

Parameter Parameter description is shown in the table below.

Parameter Description Value Range Remarks

User Label Self-defined name 40 characters at most -

Confidential and Proprietary Information of ZTE CORPORATION 15

Page 22: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

Parameter Description Value Range Remarks

Rack No./ShelfNo./Slot No.

Location of the boardwith the current serialport

Depending on BS type -

Serial Port No. Serial port No. Depending on typeof the board whichsupports serial port(The number ofserial ports supportedby different boardsvaries.)

-

Baud Rate Transmission baudrate at serial Port

{4800, 9600, 19200,38400, 57600,115200}

Consistent withserial port deviceconfiguration

AISG DeviceInterface The related interface is shown in the figure below.

Parameter Parameter description is shown in the table below.

16 Confidential and Proprietary Information of ZTE CORPORATION

Page 23: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Chapter 1 General Configuration Parameters

Parameter Description Value Range Remarks

User Label Self-Defined name 40 characters at most -

Device ID Serial number of AISGdevice

32 characters at most The first twocharacters representmanufacturer ID.

Device Type AISG device type {RET, ATMA, ACOM} -

Rack No./Shelf No. The rack/ shelf whereAISG device is located

- -

Slot No. The slot where AISGdevice is located

- For remote electricaltilt antenna, theparameter representsantenna ID; for toweramplifier, it is the IDof tower amplifier; foractive combiner, it isACOM channel ID.

AISG Version No. AISG protocol versionNo.

{1.1, 2.0} Only two AISGprotocol versionsexist currently.

CCU Rack No./ CCUShelf No./CCU SlotNo.

Location of AISG CCU(control and clockunit) at BS device

Depending on BSdevice type

-

Dry ContactInterface The related interface is shown in the figure below.

Confidential and Proprietary Information of ZTE CORPORATION 17

Page 24: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

Parameter Parameter description is shown in the table below.

Parameter Description Value Range Remarks

User Label Self-defined name 40 characters at most -

Rack No./ShelfNo./Slot No.

Location of the boardwhere dry contactsignal is inputted

- -

Dry Contact No. Dry contact port ID Depending on BS type -

Alarm Mode Setting the statusunder which thealarm is activated

{Closed, Open} When the initial stateof dry contact isopen circuit, closedcircuit produces alarmand the parameteris configured as“Closed”.

When the initial stateof dry contact isclosed circuit, opencircuit produces alarmand the parameter isconfigured as “Open”.

Alarm Content No. Alarm contentproduced afterreception of drycontact signal

{TMB downlinkbypass alarm, TMBuplink bypass alarm,Master power supplyfault, Immersionalarm, Smog alarm,Storage batteryalarm, Master powersupply over voltagealarm, master powersupply lack voltagealarm, Master powersupply broken alarm,Equipment of IndoorSurge ProtectionDevice alarm, TurnoffEquipment of IndoorSurge ProtectionDevice alarm,Shelf Indoor SurgeProtection Devicealarm, Outdoor SurgeProtection Devicealarm}

-

18 Confidential and Proprietary Information of ZTE CORPORATION

Page 25: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

C h a p t e r 2

TransmissionConfigurationParameters

Table of ContentsPhysical Layer Management ................................................19Global Port Layer Management ............................................23IP/Static Router Layer Management .....................................31Transmission Layer Management .........................................34Clock Configuration............................................................39

Physical Layer ManagementE1/T1 Link

Interface The related interface is shown in the figure below.

Confidential and Proprietary Information of ZTE CORPORATION 19

Page 26: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

Parameter Parameter description is shown in the table below.

Parameter Description Value Range

User Label Self-defined name 40 characters at most

Rack No./Shelf No./SlotNo./E1/T1 Link ID

Location which the E1/T1 linkis connected with (rack/ shelf/slot/port)

-

Link Type Far-End equipment whichE1/T1 link is connected to

{RNC, BSC, ALL}

HDLC Link

Interface The related interface is shown in the figure below.

20 Confidential and Proprietary Information of ZTE CORPORATION

Page 27: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Chapter 2 Transmission Configuration Parameters

Parameter Parameter description is shown in the table below.

Parameter Description Value Range

User Label Self-Defined Name 40 characters at most

Rack No./Shelf No./SlotNo/HDLC ID/Bearer Link Type

The type of link which bearsHDLC and the link location

-

HDLC Link ID HDLC link ID [0, 31]

Row No./Timeslot Map The E1/T1 time slot used byHDLC link

-

Confidential and Proprietary Information of ZTE CORPORATION 21

Page 28: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

Time Slot Interchange

Interface The related interface is shown in the figure below.

Parameter Parameter description is shown in the table below.

Parameter Description Value Range Remarks

User Label Self-defined name 40 characters at most -

Rack No./ShelfNo./Slot No.

Location of theinterface board wheretime slot interchangeis performed

- -

22 Confidential and Proprietary Information of ZTE CORPORATION

Page 29: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Chapter 2 Transmission Configuration Parameters

Parameter Description Value Range Remarks

In E1/T1 Link ID ID of in E1/T1 link Depending on thenumber of E1/T1 lineson interface board

-

Out E1/T1 Link ID ID of out E1/T1 link Depending on thenumber of E1/T1 lineson interface board

-

Row No./In TimeslotMap/Out TimeslotMap

To select the timeslot used in time slotinterchange

- To configure time slotto be used as “in use”

The number of in timeslots and that of outtime slots should bethe same.

Global Port LayerManagementEthernet

Interface The related interface is shown in the figure below.

Confidential and Proprietary Information of ZTE CORPORATION 23

Page 30: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

Parameter Parameter description is shown in the table below.

Parameter Description Value Range Remarks

User Label Self-defined name 40 characters at most -

Rack No./ShelfNo./Slot No./PortID

Location which theEthernet link isconnected with(rack/shelf/boardslot/port)

- -

Working Mode Ethernet workingmode

{10Mbps half-duplex,100Mbps full-duplex,Self-Adaptive,10Mbps full-duplex,100Mbps half-duplex,1000Mbps}

Inter-Operabilityparameter, consistentwith far-endequipment

Link Object Ethernet link object {IPbone, BTS} –

Bandwidth Link bandwidth [0, 100000] -

24 Confidential and Proprietary Information of ZTE CORPORATION

Page 31: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Chapter 2 Transmission Configuration Parameters

QoS Bandwidth

Interface The related interface is shown in the figure below.

Parameter Parameter description is shown in the table below.

Parameter Description Value Range Remarks

User Label Self-Defined name 40 characters at most -

Rack No./ShelfNo./Slot No./PortID

Location which theEthernet link isconnected with(rack/shelf/boardslot/port)

- -

Traffic Quality Priority Traffic quality priority [0, 255] –

Bandwidth of QoS Link bandwidth in thecase of fixed priority

– The total bandwidthfor all priorities cannotexceed the configuredEthernet bandwidth.

Confidential and Proprietary Information of ZTE CORPORATION 25

Page 32: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

PPP Link

Interface The related interface is shown in the figure below.

26 Confidential and Proprietary Information of ZTE CORPORATION

Page 33: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Chapter 2 Transmission Configuration Parameters

Confidential and Proprietary Information of ZTE CORPORATION 27

Page 34: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

Parameter Parameter description is shown in the table below.

Parameter Description Value Range Remarks

[Basic Information]

User Label Self-Defined name 40 characters at most -

Rack No./ShelfNo./Slot No.

Location of the linkwhich bears Point-to-Point Protocol(rack/shelf/board)

- -

Link Type The bottom-layerprotocol used by PPPlink

{HDLC} -

28 Confidential and Proprietary Information of ZTE CORPORATION

Page 35: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Chapter 2 Transmission Configuration Parameters

Parameter Description Value Range Remarks

Bearer Protocol Protocol type for PPPlink

{PPP, ML-PPP} –

Base Station IP Local IP Address ofPPP link

- IP address is obtainedautomatically ifparameter value is“0.0.0.0”.

Quality Protocol Service qualityprotocol

{LQR, Unsupported} -

This parameter isconfigurable onlywhen data link layerprotocol is HDLC.

HDLC No. The HDLC link whichbears PPP protocol

-

One HDLC link canbe selected whenbearer protocol is“PPP”; multiple HDLClinks may be selectedwhen bearer protocolis “ML-PPP”.

[Authentication Information]

Authentication Whether to performauthentication

{Authenticationdisabled,AuthenticationEnabled}

-

Authentication UserName

Authentication username during linkestablishment

- -

AuthenticationPassword

Authenticationpassword during linkestablishment

- -

[IP Information]

IP Compression Whether IPcompression issupported

{CompressionDisabled,CompressionEnabled}

-

Maximum PeriodBetween Full Headers

Maximum intervalpackets between fullheaders

[1, 65535] -

Maximum TimeBetween Full Headers

Maximum intervalperiod between fullheaders

[1, 255] -

Maximum TCPCompression ID

Maximum TCPcompression ID

[3, 255] -

Maximum NONTCPCompression ID

Maximum NONTCPcompression ID

[3, 65535] -

Maximum Length ofHeader

Maximum length ofcompressible header

[60, 65535] -

Confidential and Proprietary Information of ZTE CORPORATION 29

Page 36: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

Parameter Description Value Range Remarks

Type of MP Head MP header sequenceformat

{Long, Short,InValid}

MP Priority MP priority Long: [1, 16]; Short:[1, 4]

Global Port

Interface The related interface is shown in the figure below.

Parameter Parameter description is shown in the table below.

Parameter Description Value Range Remarks

User Label Self-Defined Name 40 characters at most -

Port Type Type of the link thatbears global port

{IP over Ethernet, IPover PPP}

30 Confidential and Proprietary Information of ZTE CORPORATION

Page 37: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Chapter 2 Transmission Configuration Parameters

Parameter Description Value Range Remarks

Rack No./ShelfNo./Slot No/Port ID

Location of the linkthat bears global port(rack/shelf/board/port)

- -

VLAN ID Global port VLAN ID [2, 4094] If VLAN is unused,VLAN ID is “65535”.

IP/Static Router LayerManagementIP Parameter

Interface The related interface is shown in the figure below.

Confidential and Proprietary Information of ZTE CORPORATION 31

Page 38: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

Parameter Parameter description is shown in the table below.

Parameter Description Value Range Remarks

User Label Self-Defined name 40 characters at most -

Global Port Global port ID {The created globalport}

IP Address/Subnet-work Mask/Gateway

IP addressinformation of globalport

- -

Bandwidth Bandwidth at globalport

[0, 100000] -

Living time of IP Pack Living time of IPpacket

[0, 255] –

32 Confidential and Proprietary Information of ZTE CORPORATION

Page 39: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Chapter 2 Transmission Configuration Parameters

Parameter Description Value Range Remarks

Maximum length oftraffic unit

MTU [0, 65535] Recommendedparameter value is“1450”.

Radio Mode Traffic type over IPlink

{WCDMA, GSM,WCDMA/GSM}

COS Flag COS type over IP link {1 for Support, 0 forNonsupport}

Static Router

Interface The related interface is shown in the figure below.

Parameter Parameter description is shown in the table below.

Parameter Description Value Range Remarks

User Label Self-Defined name 40 characters at most -

Confidential and Proprietary Information of ZTE CORPORATION 33

Page 40: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

Parameter Description Value Range Remarks

Static Router ID Static router ID [0, 127] -

Global Port The global port thatneeds routing

{The created globalport}

Target IP Address Target IP address Valid IP address –

Target Network Mask Target network mask – –

Next Hop Gateway Next hop gateway Valid IP address –

Transmission LayerManagementSCTP Association

Interface The related interface is shown in the figure below.

34 Confidential and Proprietary Information of ZTE CORPORATION

Page 41: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Chapter 2 Transmission Configuration Parameters

Parameter Parameter description is shown in the table below.

Parameter Description Value Range Remarks

User Label Self-Defined name 40 characters at most -

Association ID Association ID [0, 1] The maximumnumber of configuredSCTP association linksis 2.

Rack No./ShelfNo./Slot No.

Location of the boardwhich bears SCTP link

- -

Radio Mode Traffic type over SCTPlink

{WCDMA, GSM} –

Confidential and Proprietary Information of ZTE CORPORATION 35

Page 42: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

Parameter Description Value Range Remarks

No.0 Local IP Address Local IP address ofSCTP link

Valid IP -

No.1 Local IP Address Local IP address ofSCTP link

Valid IP -

No.2 Local IP Address Local IP address ofSCTP link

Valid IP -

No.3 Local IP Address Local IP address ofSCTP link

Valid IP -

Local Port Number Local port No. ofSCTP link

[0, 65535] -

Remote Port Number Remote port No. ofSCTP link

[0, 65535] -

No.0 Remote IPAddress

Local IP address ofSCTP link (on RNCside)

Valid IP -

No.1 Remote IPAddress

Local IP address ofSCTP link (on RNCside)

Valid IP –

No.2 Remote IPAddress

Local IP address ofSCTP link (on RNCside)

Valid IP –

No.3 Remote IPAddress

Local IP address ofSCTP link (on RNCside)

Valid IP –

Number ofInput/Output Streams

Number of SCTPstreams

[1, 6] -

QoS IP link QoS {EF service, Servicegroup 4, discardPriority middle;Service group 2,discard Prioritymiddle; make thebest of; Service group4, discard Priorityhigh; Service group2, discard Priorityhigh}

-

Maximum Retry Times Maximum retry timesafter packet loss

[3, 5] -

Maximum IntervalTime

Maximum intervaltime for retry afterpacket loss

[1, 30] –

Heartthrob IntervalTime

Time interval forsending SCTP statusmonitor information

[1, 300] –

36 Confidential and Proprietary Information of ZTE CORPORATION

Page 43: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Chapter 2 Transmission Configuration Parameters

SCTP Stream

Interface The related interface is shown in the figure below.

Parameter Parameter description is shown in the table below.

Parameter Description Value Range Remarks

User Label Self-Defined name 40 characters at most -

Association ID The correspondingSCTP link instream parameterconfiguration

{The created SCTPlink}

Stream ID Stream ID [0, 5] –

User Type The user type thatSCTP stream bears

{NCP, CCP,NCP+CCP}

Confidential and Proprietary Information of ZTE CORPORATION 37

Page 44: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

OMC-B Link

Interface The related interface is shown in the figure below.

Parameter Parameter description is shown in the table below.

Parameter Description Value Range

User Label Self-Defined name 40 characters at most

Rack No./Shelf No./Slot No. The interface board whichbears OMC-B connection

-

Link ID ID of OMC-B link [0, 1]

Base Station OMC IP Address IP address of the interfaceused to transmit BS operationand maintenance data packet

Configured IP address

38 Confidential and Proprietary Information of ZTE CORPORATION

Page 45: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Chapter 2 Transmission Configuration Parameters

Parameter Description Value Range

Base Station OMC Gateway Destination gateway foroperation and maintenancedata sent by BS

Valid IP address

IP Tos QoS of IP link [0, 255]

Clock ConfigurationIP Clock

Interface The related interface is shown in the figure below.

Parameter Parameter description is shown in the table below.

Parameter Description Value Range Remarks

User Label Self-Defined name 40 characters at most -

Confidential and Proprietary Information of ZTE CORPORATION 39

Page 46: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

Parameter Description Value Range Remarks

Sync server IPAddress

IP address of clocksynchronizationserver

Valid IP -

Subnet Mask Subnet mask ofclock synchronizationserver

Subnet mask –

Gateway Address Gateway address ofclock synchronizationserver

Valid IP –

IP Address for BaseStation Clock

IP address for BSclock

{The created IP} -

IP Tos QoS of IP link {EF service, Servicegroup 4, discardpriority middle;Service group 2,discard prioritymiddle; make thebest of; Service group4, discard priorityhigh; Service group2, discard priorityhigh}

SYNC Interval Time Requested timeinterval for sendingSYNC (SYNC sent byremote end)

[1, 40] -

DELAY REQUESTInterval Time

Requested timeinterval for sendingDELAY REQUEST(DELAY REQUESTsent by remote end)

[30, 120] -

Sending Mode Sending mode {one step, two step} -

Durative SYNC Time Requested durativetime for sending SYNC(SYNC sent by remoteend)

[600, 3600] -

Durative DELAYREQUEST Time

Requested durativetime for sendingDELAY REQUEST(DELAY REQUESTsent by remote end)

[600, 3600] -

40 Confidential and Proprietary Information of ZTE CORPORATION

Page 47: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Figures

Confidential and Proprietary Information of ZTE CORPORATION 41

Page 48: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

This page is intentionally blank.

42 Confidential and Proprietary Information of ZTE CORPORATION

Page 49: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

Tables

Confidential and Proprietary Information of ZTE CORPORATION 43

Page 50: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

ZXSDR B8200 GU360 Ground Parameter Reference

This page is intentionally blank.

44 Confidential and Proprietary Information of ZTE CORPORATION

Page 51: ZXSDR B8200 GU360 (V4.00.100) Indoor GSM&UMTS Dual Mode Baseband Unit Ground Parameter Reference

List of Glossary

AISG - Antenna Interface Standards Group

CCP - Communication Control Port

GSM - Global System for Mobile communication

HDLC - High-level Data Link Control

MTU - Maximum Transmission Unit

NCP - Node B Control Port

OMM - Operation & Maintenance Module

PPP - Point-to-Point Protocol

QoS - Quality of Service

RNC - Radio Network Controller

RRU - Remote Radio Unit

SA - Site Alarm Module

SCTP - Stream Control Transfer Protocol

VLAN - Virtual LAN

VSWR - Voltage Standing Wave Ratio

WCDMA - Wideband Code Division Multiple Access

Confidential and Proprietary Information of ZTE CORPORATION 45