zive – radiation monitor

13
ZIVE Next generation of radiation monitors

Upload: alexander-karpovich

Post on 13-Apr-2017

65 views

Category:

Health & Medicine


0 download

TRANSCRIPT

Page 1: Zive – radiation monitor

ZIVE Next generation of radiation monitors

Page 2: Zive – radiation monitor

ZIVEZIVE is a Bluetooth-connected ionising radiation monitor.It combines high accuracy at lower level, ergonomic design; calibrated, EC marked.

Page 3: Zive – radiation monitor

ZIVE featuresYou don’t need to be a professional to use it! ZIVE is user-friendly.Operation algorithm meets highest professional standards.

Measure the dose rate of gamma radiation and X-ray of any object.

Search and localise radiation sources. Monitor everyday background radiation

indoors and outdoors. Alarm if the radiation level exceeded the

safe level.

Page 4: Zive – radiation monitor

ZIVE + Food

Page 5: Zive – radiation monitor

ZIVE + Housebuilding

Page 6: Zive – radiation monitor

ZIVE + Travelling

Page 7: Zive – radiation monitor

ZIVE testingZIVE was validated in operational environment: in the radioactive areas of “Polesie State Radioecological Reserve” and Pripyat

Page 8: Zive – radiation monitor

ZIVE description

Page 9: Zive – radiation monitor

ZIVE technical specificationsDisplay Full color 1,5” OLED

Alarm levels Custom level and fixed level

Battery charging micro USB port

Battery life 23 hours

Communication with smartphone Bluetooth 2.0,Android 4.0.1 or later

Working temperature range - 10 °С … +50 °С

Protection class lP43

Overalldimensions 127×58×27 mm

Weight 120 g

Сonformity CE

Page 10: Zive – radiation monitor

ZIVE metrological specificationsAmbient gamma radiation and X-ray dose equivalent rate (exposure dose rate) indication range

0,05 μSv/h – 9,99 mSv/h,5 μR/h – 999 mR/h

Ambient gamma radiation and X-ray dose equivalent rate (exposure dose rate) measurement range

0,1 μSv/h – 10 mSv/h,10 μR/h – 1 R/h

Gamma radiation and X-ray energy range

50 keV – 10 MeV

Intrinsic relative error of dose rate measurement in the range from 0.1 μSv/h to 10 mSv/h (10 μR/h – 1 R/h)

± 20%

Sensitivity to 137 Cs gamma radiation

240000 CPM/mSv·h -1

2400 CPM/mR·h -1

Energy dependence relative to 662 keV ( 137Cs)

± 30%

Radiation overloading Radiation monitor can withstand 100-foldrise of dose rate measurement upper range limitfor 30 minutes with readings not lower than maximum

Anisotropy in angular spacing ±60°For 137 Cs and 60CoFor 241Am

± 10%± 30%

Page 11: Zive – radiation monitor

ZIVE appTo get the most from ZIVE, use ZIVE app to connect it with smartphone via Bluetooth.

Evaluate the background radiation Health and well-being advice Store data about radiation spots on your routes Find cleaner and safer route Create a map of radiation contamination of your

neighborhood Access the global map of radiation contamination

Page 12: Zive – radiation monitor

ZIVE data

With the help of ZIVE & app it can be possible to collect and visualize data, map software, and create real-time global map of radiation contamination.

Page 13: Zive – radiation monitor

Partnerships

SPORT COM