Parison controller
Home>> Parison Controller
New generation low cost controller for cost effective
solutionRatings
Model Code
Precaution
Features/Ratings Model Code Precaution
Sequence signalPhoto coupler inputPhoto coupler collector output
Monitor Output voltage + 10 V
Power supply 100/220 V
Power consumption Less then 20 VA
Ambient temperature 0 ~ 50 C
Sensor resolving power 0.05%
Number of interpolation points 256 points, linear interpolation
All setting are digital - Jog dial and push buttons
Very high repeatability and Easy to set
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/parison.htm (1 of 3) [28/01/2006 7:21:52 PM]
Parison controller
Display Colour Graphic LCD with Compact design
Number of points 32
Control ModeSelection of machine type: Continuous or Accumulator type
Die gap: Convergent or Divergent
Cycle modeOffMT1 automatic time cycle compensation (Previous cycle time as reference)MT2 automatic time cycle compensation (2nd cycle time as reference)
CPUDigital Servo ControlHigh Performance CPU used to get high response250 µ sec for pattern sweeping
Model Code Precaution Ratings
Parison controller SK 1121-10
High response Proportional Directional & Flow control valve ELDFG-01-**-3C2P-XY-10
These valves have high response characteristics equivalent to a servo valve. This is achieved by using a closed loop system. High tolerance to contamination due to direct control as compared to servo valve which is controlled by nozzle flapper
- Can be used as a replacement for medium range servo valve for position & pressure control- Contamination related failure & system malfunction reduces to a large extent in comparison to servo valve
Amplifier AMN-L-01-3-2P-10
Precautions Ratings Model Code
Install the controller at a place less affected by dust, humidity, vibration & a high temperature. Do not install the controller on a control panel in which high-voltage equipment is incorporated. Separate the AC power source from the power line of equipment which produces high noise. If equipment which produces high noise is adjacent to a control panel on which the control is installed, separate the
grounding cable of the controller from that of the other equipment.
For safety use
For safety, ground the controller. A cooling fan is installed inside the panel of the controller . If the panel is installed on a other panel or similar devices,
do not clog the ventilating holes on both sides of rear panel of the controller. Do not remove the case of the controller. There are high-voltage components inside the controller. Touching such
components are not only dangerous but also may cause a failure.
Accumulator Mode Continuous Extrusion type
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/parison.htm (2 of 3) [28/01/2006 7:21:52 PM]
Parison controller
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/parison.htm (3 of 3) [28/01/2006 7:21:52 PM]
Power amplifiers for ELDFG
Home>>Proportionals>>Power amplifiers
This Power amplifier is used for driving the Proportional Electro-Hydraulic Direction and flow Control Valve
Ratings For Amplifier
Max. Output Current 2.5A (3.9Ω Solenoid)
Input Impedance 10 kΩMax. Gain +3mm St./+5V
Dither 100 Hz. (Fixed)
Power Supply (range) +24V (+20V ~ +30V)DC
Ambient Temperature 0 - 55 ° C
External Setting Resistance 1 kΩMax. Input Voltage +10V (PBAT) ~ -10V
(PABT)DC
Sensor Monitar Signal Output 1.5V/ ± 3mm St
Alarm Signal Output Max. DC 3OV, l0mA
Ambient Temperature 0-50 Deg C
Ambient Humidity < 90 % RH
Mass 0.3 kg
Model number designation
AMN -L -01 -3 -2P -10
Series number
Type of functionELDFG valve size
Compensate type
ELDFG Spool Type
Design number
AMN
L: DC input Direction and flow Control type with minor feedback
01 Compensate type 3
2P: 3C2P (Zero - Lap)
10
Relationship between input signals and output current pattern
Terminal board details, mounting dimensions, Electrical block diagram
file:///D|/My%20Documents/Under%20Editing%20do...%20copyYILCATCD/yilcd/proportionalPAMPSAMN.htm [28/01/2006 7:22:14 PM]
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/inoutct.gif
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/inoutct.gif [28/01/2006 7:22:20 PM]
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/AMNdetails.gif
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/AMNdetails.gif (1 of 2) [28/01/2006 7:22:39 PM]
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/AMNdetails.gif
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/AMNdetails.gif (2 of 2) [28/01/2006 7:22:39 PM]
Flow Control and Relief Valves
Purpose of UseSimulation Machines (Simulation Games), Parison Controller and Bender etc.
Home>>Proportionals>>Direction and Flow Control ValvesHigh Response Type l/8, Proportional Electro-Hydraulic Directional and Flow Control Valves
High response, high accuracy, high reliability by employing a closed loop systems for feed back control.Especially , the valves of zero-lap type (Spool type 3C2P) are suitable for position control or pressure control. In combination with a small type intensified solenoid and a differential transducer for detecting spool position, high response, high accuracy and high reliability are realized.
Response characteristics of 52Hz/-3dB (± 25 %amplitude) equivalent to those for servo valves.The valves can be used in place of servo valves of 5OHz response class for position control or pressure control.
Excellent resistance to contaminationTroubles caused by contamination can be reduced as the valves are superior in anti-contamination to servo valves.
Ratings Instructions Model number
Ratings Instructions Model number
DescriptionModel number
ELDFG-01
Max. Operating Pres. Kgf / Cm2
315
Tank line back pressure 210
Maximum flow lpm 125
Rated flow @ Valve differential pressure of 15
Kgf / Cm2 35 lpm
Rated Current Max. 2.5A
Coil Resistance 3.9 ohms
Power input Max. 25W
Hysteresis Less Then 0.5%
Repeatability Less Then 0.5%
Step Response (0 to 100%) Less Then 30ms
Frequency ResponsePhase (-90): 48Hz
Gain(-3dB): 52Hz
Graphical symbol
Performance
file:///D|/My%20Documents/Under%20Editing%20...0copyYILCATCD/yilcd/proportionalsELDFG01.htm (1 of 3) [28/01/2006 7:22:58 PM]
Flow Control and Relief Valves
Input voltage Vs spool travel
Step response
Input voltage Vs flow
Frequency Response
Applicable Power AmplifierFor stable performance, it is recommended that Yuken' s applicable power amplifiers be usedAMN-L-01-2P-10
Ratings Model number Instructions Back to top Home
Select the values to see your model number
Series NumberELDFG - 01:
High Response type Proportional Electro- Hydraulic direction and flow control valve (Sub-plate Mounting Sub plate DSGM-
01,01X,01Y)
Rated flow
Spool Type
3C2P is Zero lap typeMounting Dimensions
Direction of Flow
XY: Meter-in.
Meter-Out
Design Number
10
This is Your Model Number
Instructions Ratings Model number Back to top Home
Hydraulic Fluids
file:///D|/My%20Documents/Under%20Editing%20...0copyYILCATCD/yilcd/proportionalsELDFG01.htm (2 of 3) [28/01/2006 7:22:58 PM]
Flow Control and Relief Valves
Fluid Types
Petroleum Base Oils : Use fluids equivalent to ISO VG 32 or VG 46. Recommended Fluid Viscosity And Temperature The recommended fluid viscosity 20 - 200mm2 /S, and temperature range is from 0 to + 60 deg C, both of which have to be satisfied for the use of the above hydraulic oils.
Control of Contamination Due caution must be paid to maintaining control over contamination of the hydraulic fluids which may otherwise lead to breakdowns and shorten the life of the valve. Maintain the degree of contamination within NAS grade The recommended viscosity range is from 20 to 200 mm 2/S and 10. Use 20 µ m or finer line filter.
Instructions
Mounting
Be sure that the air vent faces up.
The valve must be mounted with axis line L-L' angles within about +15 degrees from the horizontal plane.
Tank PipingBe sure to fill the Tank port with the hydraulic fluid.Tank pipes must be equipped with a 0.04 MPa check valves to take back pressure. Do not connect the tank pipes to other lines, but connect them directly to the reservoir. Be sure that the tank pipe ends are immersed in fluid.
Good Examples
Hysteresis and Repeatability Value Indications
The hysteresis and repeatability values indicated in the specifications for each control valve are determined under the following conditions
Hysteresis Value : Obtained when Yuken's applicable power amplifier (model : AMN-L-01--X---X--10) is used. !2 Repeatability Value: Obtained when Yuken's applicable power .4.@ . amplifier (model: AMN-L-01--X---X--10) is used under the same conditions.
Bad Examples Manual ActuatorWhen initial adjustments are to be made or when no current is supplied to the valve due to electrical failure or other problem, push the manual actuator to temporarily set the spool at the P-B-A-T flow position (see the figure below).
Air BleedingTo ensure stable control, bleed the air from solenoid completely and fill its core with oil. Bleeding can be done by slowly loosening one of the air vents at the end of the solenoid and/or at the end of the LVDT. Choose one of the three air vents which is expected to work most effectively (see the figure to the right).
file:///D|/My%20Documents/Under%20Editing%20...0copyYILCATCD/yilcd/proportionalsELDFG01.htm (3 of 3) [28/01/2006 7:22:58 PM]
Sub plate model code for DSG01 Series valves
Sub plate model code for DSG01 Series valves
Sub plate model
Sub-plate model number"C"
BSP.F"D" Thd
"E"Approx. mass kg
DSGM-01-3080 1/8
M5 10 0.8DSGM-01X-3080 ¼
DSGM-01Y-3080 3/8
Mounting Bolts
Socket Head cap screw
M5 x 45Lg (4pcs)
Tightening torque
0.5 ~ 0.7 Kgf / Cm2
[For working pressure more then 250 Kgf / Cm2 :use 0.6 ~ 0.7 Kgf / Cm2]
Bolt kit model
numberBKDSG-01-10
file:///D|/My%20Documents/Under%20Editing%20do%...ATCD/yilcd/sub_plate_model_code_for_dsg01_s.htm [28/01/2006 7:23:10 PM]
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/ELDFGmntg.gif
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/ELDFGmntg.gif [28/01/2006 7:24:24 PM]
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/inpVgVsslTravelELDFG.gif
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/inpVgVsslTravelELDFG.gif (1 of 2) [28/01/2006 7:25:16 PM]
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/inpVgVsslTravelELDFG.gif
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/inpVgVsslTravelELDFG.gif (2 of 2) [28/01/2006 7:25:16 PM]
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/steprspELDFG.gif
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/steprspELDFG.gif [28/01/2006 7:25:22 PM]
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/inpVgVsFELDFG.gif
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/inpVgVsFELDFG.gif (1 of 2) [28/01/2006 7:25:27 PM]
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/inpVgVsFELDFG.gif
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/inpVgVsFELDFG.gif (2 of 2) [28/01/2006 7:25:27 PM]
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/fqRspELDFG.gif
file:///D|/My%20Documents/Under%20Editing%20do%20not%20copyYILCATCD/yilcd/images/fqRspELDFG.gif [28/01/2006 7:25:31 PM]