YRS02 York Reference Source

Page 2: YRS02 York Reference Source - RA Mayes | EMC, RF

The YRS02 is a multi-mode reference source capable of producing a broadband noise or comb output up to 1GHz.

• Selectable noise or comb output - Flexibility across a range of applications

•Stableoutput - Repeatable measurements

•5kHzto1GHzoutput - Applications across a broad frequency spectrum

•Compactandportable -Comparisonsbetweensitesandenvironments

•Batterypowered -Nopowerorinterconnectingcableeffects on measurements

For further information please contact:

YorkEMCServices(2007)Ltd MarketSquare,UniversityofYork York,YO105DD,UK

Email: [email protected]:www.yorkemc.co.ukTel: +44 (0) 1904 324440Fax: +44 (0) 1904 324434

TheYRS02isabroadbandnoiseandcombsourcethatiscapableofproducingacontinuousnoiseoutputfrom9kHzto1GHz,oracomboffrequencieswithinthe5kHzto1GHzrange,withstepsizebeingselectedbytheuser.Thenoisegeneratorenablesobservationofdetailsoverthefullspectralrange,whilethecombgeneratorallowsforthereferencesignaloutputandnoisefloortobeviewedsimultaneously. Radiated Emissions

Forradiatedoperationtwomonopoleantennas,optimisedfordifferentfrequencybands,areavailablewhichattachtothetopoftheunit.TheYRS02isanidealsourceforcarryingoutchecksonopenareatestsites(OATS)andanechoicchambers.

TheYRS02iscompactandbatterypowered,allowingoperationasanelectricallysmallsource,whichminimisestheeffectoftheYRS02itselfwhencharacterisingtheelectromagneticenvironment.TheYRS02ishousedinametalenclosuresothatitcanbemountedindirectcontactwithametalgroundplaneasmayberequiredbysometests. Conducted Emissions

AnN-typeconnectorprovidesadirect50Ωmatchedoutput,whichcanbeusedtocarryoutchecksonconductedmeasurementsystems.Twoadaptorsareavailableasoptionalaccessories:TheLSA03providesacapacitivelinkfromtheoutputoftheYRS02toastandardIEC320mainspowerconnector.Thisallowschecksandinvestigationsonconductedmeasurementsystemstobemade,forexampleusingaLISNoranabsorbingclamp.TheNIA01providesaninterfacetoRJ11,RJ14,RJ25andRJ45standardconnectorsforconductedmeasurementsusinganISN.

Applications

•Comparisonbetweendifferentmeasurementenvironments such as OATS or anechoic chambers

•RadiatedandconductedmeasurementsystemsvalidationandverificationReferencesourcefor:

- Dailypre-testchecksasrequiredbytheaccreditationauthoritiese.g.ISO17025

- Long-termperformancemonitoring

- Cablepositioninvestigation

- Investigationofscreenedroombehaviour

- Characterisationoffilterperformance

- Cablelossmeasurements

•Measuringamplifiergainandbandwidth

•Spectrumanalyser/receiverpre-check

YRS02 York Reference Source

Page 3: YRS02 York Reference Source - RA Mayes | EMC, RF

For further information please contact:

YorkEMCServices(2007)Ltd MarketSquare,UniversityofYork York,YO105DD,UK

Email: [email protected]:www.yorkemc.co.ukTel: +44 (0) 1904 324440Fax: +44 (0) 1904 324434

YRS02 Specifications

Noise mode

Frequency range 9kHzto1GHzdirectconnectioninto50Ωsystem 30MHzto1GHzradiatedusingTLM02andMON03monopoleantennas

Temperature stability 15°Cto30°C<+/-1dB9kHzto1GHz 5°Cto40°C<+/-2.5dB9kHzto1GHz

Time stability <1dB(typicalovera12monthperiod)

Operating time 7hours(typicalwithalkalinecells)

Comb mode

Frequency range 5kHzto1GHzdirectconnectioninto50Ωsystem 30MHzto1GHzradiatedusingTLM02andMON03monopoleantennas

Comb Signal Step size Selectable between:

10kHz (5kHz,15kHz,25kHz…3.005MHzmin.) 100kHz (50kHz,150kHz,250kHz…30.05MHzmin.) 1MHz (0.5MHz,1.5MHz,2.5MHz…300.5MHzmin.) 5MHz (2.5MHz,7.5MHz,12.5MHz…1.0025GHzmin.)

Temperature stability Amplitude:

15°Cto30°C <+/-0.5dB5kHzto1GHz 5°Cto40°C <+/-1dB5kHzto1GHz

Frequency:

5°Cto40°C <+/-0.5ppm

Time stability <1dB(typicalover12monthperiod) <+/-1ppm(typicalovera12monthperiod)

Operating time 8hours(typicalwithalkalinecells)

Other

Output connector 50ΩN-typesocket

Dimensions 120mmx120mmx60mm(79mmincludingconnector)

Weight 1kg(includingcells)

Power supply 4x1.5Vcells(AAorequivalent).Alkalineorrechargeable.

Indicators Active–greenLED Batterylow–redLED

Controls RotaryswitchformodeselectionincludingOFF

Page 4: YRS02 York Reference Source - RA Mayes | EMC, RF

For further information please contact:

YorkEMCServices(2007)Ltd MarketSquare,UniversityofYork York,YO105DD,UK

Email: [email protected]:www.yorkemc.co.ukTel: +44 (0) 1904 324440Fax: +44 (0) 1904 324434

YRS02 Standard order kits

Part No. Desciption

YRS02KIT01 StandardYRS02referencesource kitwithantenna

Antenna TLM02

MON03

Direct coupler LSA03

NIA01

Parts included

•YRS02referencesource•200MHzto1GHz(optimum)270mmlongmonopoleantenna–MON03

•Hardcase•4xAAcells•Manual•StandardtestCAL16

30MHzto300MHz(optimum)290mmlongtop-loadedmonopole

200MHzto1GHz(optimum)270mmlongmonopoleantenna

LISNadaptorwithIECsocket

ISNadaptorwithtwodatasocketoutputs 6wayRJ11/RJ14/RJ25socket/8wayRJ45socket.

Accessories

YRS02KIT02 EnhancedYRS02referencesource kitwithmultipleantennasandLISN adaptor

•YRS02referencesource•30MHzto300MHz(optimum)270mmlong top-loadedmonopole-TLM02

•200MHzto1GHz(optimum)270mmlongmonopoleantenna–MON03

•LISNadapterwithIEC-styleconnection–LSA03•Hardcase•4xAAcells•Manual•StandardtestCAL16

Direct output CAL16

Radiated output CAL17

CAL18

0to1GHzpowermeasurementusingspectrumanalyzer,allmodes

30MHzto1GHzhorizontalandverticalpolarisationelectricfield-strengthonOATSusingreceiver,either3mor10mtestdistance.Resultsfornoise,1MHzand5MHzcombmodes.

30MHzto1GHzhorizontalandverticalpolarisationelectricfieldstrengthinFARusingaspectrumanalyserat3mtestdistance. Resultsfornoise,1MHzand5MHzcombmodes.

Output measurement results

Page 5: YRS02 York Reference Source - RA Mayes | EMC, RF

For further information please contact:

YorkEMCServices(2007)Ltd MarketSquare,UniversityofYork York,YO105DD,UK

Email: [email protected]:www.yorkemc.co.ukTel: +44 (0) 1904 324440Fax: +44 (0) 1904 324434

YRS02 Typical output measurement resultsMeasured using a spectrum analyser – Noise output

Page 6: YRS02 York Reference Source - RA Mayes | EMC, RF

For further information please contact:

YorkEMCServices(2007)Ltd MarketSquare,UniversityofYork York,YO105DD,UK

Email: [email protected]:www.yorkemc.co.ukTel: +44 (0) 1904 324440Fax: +44 (0) 1904 324434

YRS02 Typical output measurement resultsMeasured using a spectrum analyser – Comb output