xt-mq · 2016-06-03 · xt-mq ieeia pesse gages 2013-12-19 design and specifications subject to...

3
www.baumer.com MX-MZ-MT-MQ Differential pressure gauges 2013-12-19 Design and specifications subject to change without notice Page 1 / 3 Data sheet A24.02 MX-MZ-MT-MQ Differential pressure gauges Page 1 / 3 Main Features Applications For corrosive process fluids and atmospheres Accuracy ± 2 % F.S. Static pressure max. 100 bar Housing and wetted parts stainless steel Food & Beverage Laboratory & Medical Oil & Gas / Chemical Water & Waste water Energy Transportation & Logistics Machinery Technical Data Nominal size 150 mm Measurement range 0 ... 0.1 to 0 ... 25 bar Static pressure Selectable, max. 100 bar (see table on page 2) Allowed single-sided overpressure Up to the selected static pressure, limited at a maximum of 25 bar Accuracy ± 2 % F.S. for standard ranges (see table on page 2) Protection rating IP 65 (EN 60529) Process connection Stainless steel 1.4404 (AISI 316L) Bellows Stainless steel 1.4404 (AISI 316L) (2 bellows per gauge) Case Stainless steel 1.4301 (AISI 304) Bezel ring Stainless steel 1.4301 (AISI 304) Movement Stainless steel Options Polycarbonate window with index pointer adjustable by fixed button Code 0052 ATEX II2GDc-IM2c (Including window laminated safety glass) Code 0078 Adjustable micro metric pointer (P ≥ 0.6 bar) Code 0678 Adjustable friction pointer Code 0679 Window laminated safety glass (included in type MT and MQ) Code 0751 Window Plexiglas Code 0752 Window Hardened glass Code 0756 Oxygen application Code 0765 Laboratory cleanliness Code 0835 Nuclear cleanliness Code 0838 To be ordered separately Material certificate 3.1 EN10204 Code Q1229 Calibration certificate EN837-1 (5 points raising and 5 points falling) Code Q1070 Window MX, MZ : instrument glass MT, MQ : laminated safety glass Window gasket Elastomer Dial Aluminium, white Pointer Aluminium, black Temperature Ambient : -20 ... +70°C Medium : -40 ... +200°C (not filled) For liquid filled version see ordering details. The case temperature must not exceed +70°C Storage : -40 ... +70°C Safety Pressure gauge with blow-out device Fulfills requirements for S1 gauges according to EN 837

Upload: others

Post on 15-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: XT-MQ · 2016-06-03 · XT-MQ ieeia pesse gages 2013-12-19 Design and specifications subject to change without notice aa see A Page 3 / 3 Ordering details MX-MZ-MT-MQ Differential

www.baumer.com

MX-MZ-MT-MQDifferential pressure gauges

2013

-12-

19

D

esig

n an

d sp

ecifi

catio

ns s

ubje

ct to

cha

nge

with

out n

otic

e

Page 1 / 3Data sheet A24.02

MX-MZ-MT-MQDifferential pressure gauges

Page 1 / 3

Main Features

Applications

�� For corrosive process fluids and atmospheres�� Accuracy ± 2 % F.S.�� Static pressure max. 100 bar�� Housing and wetted parts stainless steel

�� Food & Beverage�� Laboratory & Medical�� Oil & Gas / Chemical�� Water & Waste water

�� Energy�� Transportation & Logistics�� Machinery

Technical Data

Nominal size 150 mmMeasurement range 0 ... 0.1 to 0 ... 25 barStatic pressure Selectable, max. 100 bar (see table on page 2)Allowed single-sided overpressure

Up to the selected static pressure, limited at a maximum of 25 bar

Accuracy ± 2 % F.S. for standard ranges(see table on page 2)

Protection rating IP 65 (EN 60529)Process connection Stainless steel 1.4404 (AISI 316L)Bellows Stainless steel 1.4404 (AISI 316L)

(2 bellows per gauge)Case Stainless steel 1.4301 (AISI 304) Bezel ring Stainless steel 1.4301 (AISI 304) Movement Stainless steel

Options

Polycarbonate window with index pointer adjustableby fixed button

Code 0052

ATEX II2GDc-IM2c(Including window laminated safety glass)

Code 0078

Adjustable micro metric pointer (P ≥ 0.6 bar) Code 0678

Adjustable friction pointer Code 0679Window laminated safety glass(included in type MT and MQ)

Code 0751

Window Plexiglas Code 0752

Window Hardened glass Code 0756Oxygen application Code 0765Laboratory cleanliness Code 0835Nuclear cleanliness Code 0838

To be ordered separatelyMaterial certificate 3.1 EN10204 Code Q1229Calibration certificate EN837-1(5 points raising and 5 points falling)

Code Q1070

Window MX, MZ : instrument glassMT, MQ : laminated safety glass

Window gasket ElastomerDial Aluminium, whitePointer Aluminium, black

Temperature Ambient : -20 ... +70°CMedium : -40 ... +200°C (not filled)For liquid filled version see ordering details.The case temperature must not exceed +70°CStorage : -40 ... +70°C

Safety Pressure gauge with blow-out deviceFulfills requirements for S1 gauges according to EN 837

Page 2: XT-MQ · 2016-06-03 · XT-MQ ieeia pesse gages 2013-12-19 Design and specifications subject to change without notice aa see A Page 3 / 3 Ordering details MX-MZ-MT-MQ Differential

www.baumer.com

MX-MZ-MT-MQDifferential pressure gauges

2013

-12-

19

D

esig

n an

d sp

ecifi

catio

ns s

ubje

ct to

cha

nge

with

out n

otic

e

Page 2 / 3Data sheet A24.02

Pressure ranges

Code Bar

B08 0 ... 0.1

B09 0 ... 0.16

B10 0 ... 0.25

B11 0 ... 0.4

B12 0 ... 0.6

B15 0 ... 1

B16 0 ... 1.6

B18 0 ... 2.5

B19 0 ... 4

B20 0 ... 6

B22 0 ... 10

B24 0 ... 16

B26 0 ... 25

Weight (kg)Filled : 2.5

Unfilled : 1.6

Code kPa

D08 0 ... 10

D09 0 ... 16

D10 0 ... 25

D11 0 ... 40

D12 0 ... 60

D15 0 ... 100

D16 0 ... 160

D18 0 ... 250

D19 0 ... 400

D20 0 ... 600

D22 0 ... 1 000

D24 0 ... 1 600

D26 0 ... 2 500

Code kg/cm²

F08 0 ... 0.1

F09 0 ... 0.16

F10 0 ... 0.25

F11 0 ... 0.4

F12 0 ... 0.6

F15 0 ... 1

F16 0 ... 1.6

F18 0 ... 2.5

F19 0 ... 4

F20 0 ... 6

F22 0 ... 10

F24 0 ... 16

F26 0 ... 25

Dimensions - Types of mounting

61.7

78.2

Ø15

0.2

Ø18

0

Ø180

Ø168

45° 45°

81.8

23.7

Ø18

0

Ø15

0.2

45°

168

45° 20

78.2

Ø15

0.2

Ø14

2

45° 45°

78.2

33

Ø18

0

Ø15

0.2

33

97.4

Ø14

2

76.2

Ø15

0.2

carré 22

54

88

81.8168

54

88

61.778.2168

.

54 20

88

Type A Type D Type C

MX - MT

MZ - MQ

Type B Type F

81.8

80

33

Ø168Ø180

Type E

3 holes Ø 5.5at 120°C

Type A Type C Type D

20

2"145

3 max

151

168

Panel cut-out

Type B or C

MX - MZ - MT - MQ

Type P

● Scale 270°, accuracy ± 2 % (± 3 % with liquid filling)1) Scale 270°, accuracy ± 4 % (± 5 % with liquid filling)2) Scale < 270°, accuracy ± 4 % (± 5 % with liquid filling)

A C D E F G H J K L M N

1) 1) 2) 2) 2) 2)

1) 1) 1) 2) 2) 2) 2)

● ● ● ● 1) 1) 1) 2)

● ● ● ● ● 1) 1) 2) 2)

● ● ● ● ● ● 1) 1) 2)

● ● ● ● ● ● 1) 1) 2)

● ● ● ● ● ● 1) 2)

● ● ● ● ● ● 1)

● ● ● ● 1) 1) 2)

● ● ● ● ● 2) 2)

● ● ● ● 1) 2)

● ● ● ● 1)

● ● ● ●

0.6 1 1.6 2.5 4 6 10 16 25 40 60 100

Ordering code for maximum static pressure

Static pressure (bar)

Page 3: XT-MQ · 2016-06-03 · XT-MQ ieeia pesse gages 2013-12-19 Design and specifications subject to change without notice aa see A Page 3 / 3 Ordering details MX-MZ-MT-MQ Differential

www.baumer.com

MX-MZ-MT-MQDifferential pressure gauges

2013

-12-

19

D

esig

n an

d sp

ecifi

catio

ns s

ubje

ct to

cha

nge

with

out n

otic

e

Page 3 / 3Data sheet A24.02

Ordering details MX-MZ-MT-MQ

Differential pressure gauge

Nominal size 150 mm

Back connection, front flange, 3 mounting holes, case material 1.4301

Process connection 1/2 NPT

No liquid filling

Scale bar : 0 ... 10 bar

Max. static pressure : 10 bar

Option : Window laminated safety glassOption : Adjustable friction pointer

M 7 – . xxx /ModelDifferential pressure gauge M

Type of housingProcess connection 90° bottom (V-type) or lower back XProcess connection 90° bottom (V-type) or lower back, baffle wall TProcess connection bottom parallel ZProcess connection bottom parallel, baffle wall Q

Nominal size150 mm 7

–Type of mounting

Stainless steel case and bezel ring 1.4301 (AISI 304)Bottom connection, back flange for wall mounting, 3 mounting holes ABack connection, front flange, 3 mounting holes (1) BBottom connection, front flange, 3 mounting holes CBottom connection DBack connection, back flange for wall mounting, 3 mounting holes (1) EBack connection (1) FBottom connection with mounting bracket for 2” tubes P

Stainless steel case and bezel ring 1.4404 (AISI 316L)Bottom connection, back flange for wall mounting, 3 mounting holes 1Back connection, front flange, 3 mounting holes (1) 2Bottom connection, front flange, 3 mounting holes 3Bottom connection 4Back connection, back flange for wall mounting, 3 mounting holes (1) 5Back connection (1) 6Bottom connection with mounting bracket for 2” tubes 8Process connection G 1/2 31/2 NPT 6LiquidfillingDry 0BH1: low viscosity glycerin/water 86% (medium : -20 ... +70°C) (2) 1BH2: high viscosity glycerin 99.5% (medium : 0 ... +90°C) (2) 2BH3: silicone oil (medium : -40 ... +100°C) (2) 3BH4: low temperature silicone (medium : -60 ... +100°C) (2) 4BH5: Fluor carbon for oxygen use (medium : -15 ... +100°C) (2) 5

.Unit of measurement / Pressure ranges bar Bxxpsi HxxkPa DxxMPa Exxmbar Nxxkg/cm² Fxx

Max. static pressureSee table on page 2 xOptions to be added behind the / (see example below) /(1) Not available for types of housing Z and Q(2) The accuracy of filled gauges is reduced (see table on page 2)

Ordering example with options

MX 7 – B 6 0 . B22 H / 0751 _ 0679