xortel es 203 021 17772updates.xorcom.com/certs/xortel_es 203 021_17772.pdf · 2008-09-23 ·...

70
Hermon Laboratories Ltd. P.O.Box 23, Binyamina 30550, Israel Tel. +972-4-6288001 Fax. +972-4-6288277 E-mail: [email protected] Page 1 of 70 Report ID: XORTEL_ES 203 021_17772.doc Date of Issue: 9/23/2008 839.01 TEST REPORT ACCORDING TO: ETSI ES 203 021-2 V2.1.2 (2006-01) ETSI ES 203 021-3 V2.1.2 (2006-01) Access and Terminals (AT); Harmonized basic attachment requirements for Terminals for connection to analogue interfaces of the Telephone Networks; Update of the technical contents of TBR 021, EN 301 437, TBR 015, TBR 017; FOR: Xorcom Ltd. EQUIPMENT UNDER TEST: Astribank FXO module This report is in conformity with ISO/ IEC 17025. The "A2LA Accredited" symbol endorsement applies only to the tests and calibrations that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested. This test report shall not be reproduced in any form except in full with the written approval of Hermon Laboratories Ltd.

Upload: others

Post on 21-Apr-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

  • Hermon Laboratories Ltd. P.O.Box 23, Binyamina 30550, Israel Tel. +972-4-6288001 Fax. +972-4-6288277 E-mail: [email protected]

    Page 1 of 70 Report ID: XORTEL_ES 203 021_17772.doc Date of Issue: 9/23/2008

    839.01

    TEST REPORT

    ACCORDING TO: ETSI ES 203 021-2 V2.1.2 (2006-01) ETSI ES 203 021-3 V2.1.2 (2006-01) Access and Terminals (AT);

    Harmonized basic attachment requirements for Terminals for connection to analogue interfaces of the Telephone Networks; Update of the technical contents of TBR 021, EN 301 437, TBR 015, TBR 017;

    FOR: Xorcom Ltd. EQUIPMENT UNDER TEST:

    Astribank FXO module

    This report is in conformity with ISO/ IEC 17025. The "A2LA Accredited" symbol endorsement applies only to the tests and calibrations that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested.

    This test report shall not be reproduced in any form except in full with the written approval of Hermon Laboratories Ltd.

  • Report ID: XORTEL_ES 203 021_17772.doc Date of Issue: 9/23/2008

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 2 of 70

    Table of contents

    1� Client information ........................................................................................................................................................... 3�

    2� Equipment Under Test ................................................................................................................................................... 3�

    3� Manufacturer information ............................................................................................................................................... 3�

    4� Test project performance ............................................................................................................................................... 3�

    5� Test report summary ...................................................................................................................................................... 4�

    6� EUT description ............................................................................................................................................................. 5�

    7� Test laboratory description ............................................................................................................................................. 5�

    8� Test equipment used ..................................................................................................................................................... 5�

    9� Requirement conditions table ......................................................................................................................................... 6�

    10� Equipment Photographs ................................................................................................................................................ 7�

    11� Test results summary ................................................................................................................................................... 10�

    12� Detailed test results ..................................................................................................................................................... 12�

  • Report ID: XORTEL_ES 203 021_17772.doc Date of Issue: 9/23/2008

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 3 of 70

    1 Client information

    Client name: Xorcom Ltd.

    Address: Teradion Industrial Park, Misgav, 20179, Israel

    Telephone: 04-9990285

    Fax: 04-9990285

    E-mail: [email protected]

    Contact name: Izzy Gal

    2 Equipment Under Test

    Product name: Astribank FXO module Product type: FXO module for Astribank and XR series IP-PBX

    Model(s): 8 FXO module

    Serial number: n/a

    Receipt date 9/14/2008

    3 Manufacturer information

    Manufacturer name: Xorcom Ltd.

    Address: Teradion Industrial Park, Misgav, 20179, Israel

    Telephone: 04-9990285

    Fax: 04-9990285

    E-Mail: [email protected]

    Contact name: Izzy Gal

    4 Test project performance

    Project ID: 17772

    Location: Hermon Laboratories Ltd. P.O.Box 23, Binyamina 30550, Israel

    Test started: 9/14/2008 11:00:00 AM

    Test completed: 9/23/2008

    Test specification(s): ETSI ES 203 021-2 V2.1.2 (2006-01)

    ETSI ES 203 021-3 V2.1.2 (2006-01)

    Access and Terminals (AT);

    Harmonized basic attachment requirements for Terminals for connection to analogue interfaces of the Telephone Networks;

    Update of the technical contents of TBR 021, EN 301 437, TBR 015, TBR 017;

    Test suite: ETSI ES 203 021 (Analog TE) (6/11/2008 3:00:48 PM, modified)

  • Report ID: XORTEL_ES 203 021_17772.doc Date of Issue: 9/23/2008

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 4 of 70

    5 Test report summary

    Testing was completed against all relevant requirements of the test standard. The results obtained indicate that the product under test complies in full with the requirements tested.

    The test results relate only to the items tested.

    A summary of the test status of the product under test with respect to each test requirement of the standard is provided in section 11 on page 10 of this report.

    Detailed test results are presented in section 12 following page 12 of this report.

    Name and Title Date Signature

    Tested by: E.Roizman, test engineer 23-Sep-2008

    Reviewed by: E.Korsunsky, test engineer 23-Sep-2008

    Approved by: A.Usoskin, QA manager 23-Sep-2008

  • Report ID: XORTEL_ES 203 021_17772.doc Date of Issue: 9/23/2008

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 5 of 70

    6 EUT description

    FXO module for Astribank and XR series IP-PBX. Up to 8 ports per module. This module is designed to work with Asterisk GPL IP-PBX and other GPL packages.

    It is manufacturer responsibility to implement the changes in the production version of the EUT. In any case the test report applies to the tested item only.

    7 Test laboratory description

    Tests were performed at Hermon Laboratories Ltd., which is a fully independent, private, EMC, safety, environmental and telecommunication testing facility. Hermon Laboratories is listed by the Federal Communications Commission (USA) for all parts of Code of Federal Regulations 47 (CFR 47) and by Industry Canada for electromagnetic emissions (file numbers IC 2186-1 for OATS and IC 2186-2 for anechoic chamber), certified by VCCI, Japan (the registration numbers are R-808 for OATS, R-1082 for anechoic chamber, C-845 for conducted emissions site), assessed by TNO Certification EP&S (Netherlands) for a number of EMC, telecommunications, environmental, safety standards, and by AMTAC (UK) for safety of medical devices. The laboratory is accredited by American Association for Laboratory Accreditation (USA) according to ISO/IEC 17025 for electromagnetic compatibility, product safety, telecommunications testing and environmental simulation (for exact scope please refer to Certificate No. 839.01) and approved by Israel Ministry of environmental protection, radiation hazards department (Permit number 1158).

    Address: P.O. Box 23, Binyamina 30500, Israel.

    Telephone: +972 4628 8001

    Fax: +972 4628 8277

    e-mail: [email protected]

    website: www.hermonlabs.com

    Person for contact: Mr. Alex Usoskin, QA manager.

    8 Test equipment used

    Description Model S/N Hardware Rev. Software Rev. Last Calibration

    Telecom Conformance Analyzer

    Hermon Laboratories TCA 8200

    8733 A4.05 2.4.0 06/19/2008

  • Report ID: XORTEL_ES 203 021_17772.doc Date of Issue: 9/23/2008

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 6 of 70

    9 Requirement conditions table

    Condition Applies

    Is the TE intended the connection to the PSTN? Yes

    Is the TE intended to have a connection to earth? Yes

    Is the TE intended to be connected as a single terminal? No

    Is the TE intended to be in loop state? Yes

    Is the TE intended for call answer? Yes

    Is the TE intended for call set-up? Yes

    Is the TE intended for dialling with DTMF? Yes

    Is the TE intended for automatic dialling without dial tone detection? Yes

    Is the TE intended for automatic dialling with dial tone detection? No

    Is the TE intended for use in receiving mode? Yes

    Is the TE intended for use in transmitting mode? Yes

    Is the TE only intended to function on lines that provide more than 18mA of line current? No

    Is the TE intended for making internally generated automatically repeated call attempts? No

    Is the TE intended for automatically controlled signalling tone duration? Yes

    Is the TE intended for automatically controlled signalling pause duration? Yes

    Is the TE intended for Pulse Dialing? No

    Is the TE intended for Register Recall? No

    Is the TE able to go off-hook during a ringing pulse? Yes

    Is the TE intended to interwork on a low voltage line? Yes

    Is the TE intended 67% break period for Pulse Dialling? No

    Is the TE intended 60% break period for Pulse Dialling? No

    Is the TE able to go off-hook during a ringing pulse without DC? Yes

  • Report ID: XORTEL_ES 203 021_17772.doc Date of Issue: 9/23/2008

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 7 of 70

    10 Equipment Photographs

    Photograph 1

    Astribank, general view

    Photograph 2

    Astribank, rear view

  • Report ID: XORTEL_ES 203 021_17772.doc Date of Issue: 9/23/2008

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 8 of 70

    Photograph 3

    Astribank, internal view

  • Report ID: XORTEL_ES 203 021_17772.doc Date of Issue: 9/23/2008

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 9 of 70

    Photograph 4

    8 FXO module PCB, top view

    Photograph 5

    8 FXO module PCB, bottom view

  • Report ID: XORTEL_ES 203 021_17772.doc Date of Issue: 9/23/2008

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 10 of 70

    11 Test results summary

    Test Status

    ETSI ES 203 021-2 V2.1.2 (2006-01)

    4.1 Impedance unbalance about earth

    4.1.1 Quiescent state Pass

    4.1.2 Loop steady state

    4.1.2.1 Longitudinal conversion loss Pass

    4.1.2.1 Longitudinal conversion loss (loop current > 18 mA) Not required

    4.1.2.2 Output signal balance Pass

    4.1.2.2 Output signal balance (loop current > 18 mA) Not required

    4.2 Sending level limitations

    4.2.1 Mean sending level Pass

    4.2.1 Mean sending level (loop current > 18 mA) Not required

    4.2.2 Instantaneous voltage Pass

    4.2.2 Instantaneous voltage (loop current > 18 mA) Not required

    4.2.3 Sending level in a 10 Hz bandwidth Pass

    4.2.3 Sending level in a 10 Hz bandwidth (loop current > 18 mA) Not required

    4.2.4 Sending level between 4,3 kHz and 200 KHz

    4.2.4.1 Sending level between 4,3 kHz and 200 KHz during DTMF dialling Pass

    4.2.4.1 Sending level between 4,3 kHz and 200 KHz during DTMF dialling (loop current > 18 mA)

    Not required

    4.2.4.2 Sending level between 4,3 kHz and 200 KHz during communication Pass

    4.2.4.2 Sending level between 4,3 kHz and 200 KHz during communication (loop current > 18 mA)

    Not required

    4.2.5 Sending level from 200 kHz to 30 MHz

    4.2.5 Sending level from 200 kHz to 3 MHz Pass

    4.2.5 Sending level from 200 kHz to 3 MHz (loop current > 18 mA) Not required

    4.2.5 Sending level from 3 MHz to 30 MHz Pass

    4.2.5 Sending level from 3 MHz to 30 MHz (loop current > 18 mA) Not required

    4.3 Power feeding limitation Pass

    4.4 Automatically repeated call attempts Not required

    ETSI ES 203 021-3 V2.1.2 (2006-01)

    4.4 General requirements in quiescent state

    4.4.1 DC Resistance Pass

    4.4.1 DC Resistance (single terminal) Not required

    4.4.2 Characteristics of TE for ringing signals

    4.4.2.1 Impedance Pass

    4.4.2.1 Impedance (single terminal) Not required

    4.4.2.2 Transient response Pass

    4.4.2.3 DC current Pass

    4.4.3 Resistance to earth Pass

    4.4.3 Resistance to earth (single terminal) Not required

    4.4.4 Impedance Pass

  • Report ID: XORTEL_ES 203 021_17772.doc Date of Issue: 9/23/2008

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 11 of 70

    4.5 Ringing signal detector sensitivity Pass

    4.6 Transition from quiescent to loop state

    4.6.1 Acceptance of breaks in the loop in a call attempt Pass

    4.6.2 Loop current characteristics Pass

    4.6.2 Loop current characteristics (loop current > 18 mA) Not required

    4.6.3 Ring trip Pass

    4.6.4 On-Hook to Off-Hook transition with ringing without DC Pass

    4.6.4 On-Hook to Off-Hook transition with ringing without DC (loop current > 18 mA) Not required

    4.7 General loop steady state requirements

    4.7.1 DC characteristics Pass

    4.7.1 DC characteristics (loop current > 18 mA) Not required

    4.7.2 Impedance Pass

    4.7.2 Reactive component of the impedance Pass

    4.7.2 Impedance (loop current > 18 mA) Not required

    4.7.2 Reactive component of the impedance (loop current > 18 mA) Not required

    4.7.3 Resistance to earth Pass

    4.8 Call attempt

    4.8.1 Automatic dialling

    4.8.1.1 Dialling without dial tone detection Pass

    4.8.1.2 Dialling with dial tone detection Not required

    4.8.2 DTMF signalling

    4.8.2.1 Frequency combinations. 4.8.2.4 Tone duration. 4.8.2.5 Pause duration Pass

    4.8.2.2 Signalling levels. 4.8.2.3 Unwanted frequency components Pass

    4.8.2.2 Signalling levels. 4.8.2.3 Unwanted frequency components (loop current > 18 mA)

    Not required

    4.8.3 Loop disconnect dialling

    4.8.3.1 Timing for TE with break period 67% Not required

    4.8.3.1 Timing for TE with break period 60% Not required

    4.8.3.2 Make period current Not required

    4.8.3.3 Break period current Not required

    4.8.4 Register recall

    4.8.4.1 Break period duration (90-120 ms) Not required

    4.8.4.1 Break period duration (220-300 ms) Not required

    4.8.4.2 Break period current Not required

    4.8.5 Call attempt on a low voltage line Pass

    4.9 Transition from loop to quiescent state Pass

  • Report ID: XORTEL_ES 203 021_17772.doc Date of Issue: 9/23/2008

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 12 of 70

    12 Detailed test results

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.1.1 Quiescent state

    Test purpose: To ensure that the impedance unbalance about earth, expressed as Longitudinal Conversion Loss, meets the requirements.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 12:50:03 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 13 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    In range 0 to 40 dB ±0.97 dB

    In range 40 to 70 dB ±1.85 dB

    General parameters

    Parameter Value

    Series resistance 400 Ohm

    Feed voltage 50 V

    Stimulus level 775 mV

    Longitudinal conversion loss, conditions 1 to 2

    LCL

    (dB

    )

    100 1000

    40.00

    45.00

    50.00

    55.00

    60.00

    65.00

    70.00

    75.00

    Frequency (Hz)

    –––– Limit

    –––– Result - Condition 1: Feed polarity: Normal

    –––– Result - Condition 2: Feed polarity: Reverse

    Longitudinal conversion loss

    Frequency LCL Limit Verdict

    Condition 1: Feed polarity: Normal Pass

    50 Hz 65.45 dB 40 dB Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.1.1 Quiescent state

    Test purpose: To ensure that the impedance unbalance about earth, expressed as Longitudinal Conversion Loss, meets the requirements.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 12:50:03 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 14 of 70

    Frequency LCL Limit Verdict

    67 Hz 66.31 dB 40 dB Pass

    88 Hz 66.05 dB 40 dB Pass

    118 Hz 67.45 dB 40 dB Pass

    156 Hz 68.64 dB 40 dB Pass

    208 Hz 69.59 dB 40 dB Pass

    277 Hz 70.34 dB 40 dB Pass

    368 Hz 70.86 dB 40 dB Pass

    490 Hz 71.22 dB 40 dB Pass

    652 Hz 71.53 dB 46 dB Pass

    867 Hz 71.56 dB 46 dB Pass

    1152 Hz 71.68 dB 46 dB Pass

    1534 Hz 71.87 dB 46 dB Pass

    2041 Hz 71.75 dB 46 dB Pass

    2717 Hz 71.41 dB 46 dB Pass

    3623 Hz 70.67 dB 40 dB Pass

    3817 Hz 70.47 dB - -

    Condition 2: Feed polarity: Reverse Pass

    50 Hz 64.30 dB 40 dB Pass

    67 Hz 64.68 dB 40 dB Pass

    88 Hz 66.19 dB 40 dB Pass

    118 Hz 67.60 dB 40 dB Pass

    156 Hz 68.84 dB 40 dB Pass

    208 Hz 69.81 dB 40 dB Pass

    277 Hz 70.55 dB 40 dB Pass

    368 Hz 71.11 dB 40 dB Pass

    490 Hz 71.47 dB 40 dB Pass

    652 Hz 71.80 dB 46 dB Pass

    867 Hz 71.84 dB 46 dB Pass

    1152 Hz 72.22 dB 46 dB Pass

    1534 Hz 72.33 dB 46 dB Pass

    2041 Hz 72.23 dB 46 dB Pass

    2717 Hz 71.92 dB 46 dB Pass

    3623 Hz 71.22 dB 40 dB Pass

    3817 Hz 71.02 dB - -

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.1.2.1 Longitudinal conversion loss

    Test purpose: To ensure that the impedance unbalance about earth, expressed as Longitudinal Conversion Loss, meets the requirements.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 2:20:04 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 15 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    In range 0 to 40 dB ±0.97 dB

    In range 40 to 70 dB ±1.85 dB

    General parameters

    Parameter Value

    Feed voltage 50 V

    Stimulus level 775 mV

    Longitudinal conversion loss, conditions 1 to 4

    LCL

    (dB

    )

    100 1000

    40.00

    45.00

    50.00

    55.00

    60.00

    65.00

    70.00

    75.00

    80.00

    Frequency (Hz)

    –––– Limit

    –––– Result - Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm

    –––– Result - Condition 2: Feed polarity: Reverse, Series resistance: 850 Ohm

    –––– Result - Condition 3: Feed polarity: Normal, Series resistance: 2.05 kOhm

    –––– Result - Condition 4: Feed polarity: Reverse, Series resistance: 2.8 kOhm

    Longitudinal conversion loss

    Frequency LCL Limit Verdict

    Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm Pass

    50 Hz 69.99 dB 40 dB Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.1.2.1 Longitudinal conversion loss

    Test purpose: To ensure that the impedance unbalance about earth, expressed as Longitudinal Conversion Loss, meets the requirements.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 2:20:04 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 16 of 70

    Frequency LCL Limit Verdict

    67 Hz 69.77 dB 40 dB Pass

    88 Hz 72.94 dB 40 dB Pass

    118 Hz 73.22 dB 40 dB Pass

    156 Hz 70.19 dB 40 dB Pass

    208 Hz 71.15 dB 40 dB Pass

    277 Hz 71.45 dB 40 dB Pass

    368 Hz 71.57 dB 40 dB Pass

    490 Hz 71.11 dB 40 dB Pass

    652 Hz 71.27 dB 46 dB Pass

    867 Hz 71.72 dB 46 dB Pass

    1152 Hz 71.42 dB 46 dB Pass

    1534 Hz 72.05 dB 46 dB Pass

    2041 Hz 71.73 dB 46 dB Pass

    2717 Hz 71.63 dB 46 dB Pass

    3623 Hz 71.71 dB 40 dB Pass

    3817 Hz 71.78 dB 40 dB Pass

    Condition 2: Feed polarity: Reverse, Series resistance: 850 Ohm Pass

    50 Hz 68.26 dB 40 dB Pass

    67 Hz 70.69 dB 40 dB Pass

    88 Hz 71.70 dB 40 dB Pass

    118 Hz 72.38 dB 40 dB Pass

    156 Hz 73.14 dB 40 dB Pass

    208 Hz 73.07 dB 40 dB Pass

    277 Hz 72.79 dB 40 dB Pass

    368 Hz 72.69 dB 40 dB Pass

    490 Hz 72.53 dB 40 dB Pass

    652 Hz 72.31 dB 46 dB Pass

    867 Hz 72.26 dB 46 dB Pass

    1152 Hz 72.33 dB 46 dB Pass

    1534 Hz 72.60 dB 46 dB Pass

    2041 Hz 72.36 dB 46 dB Pass

    2717 Hz 72.38 dB 46 dB Pass

    3623 Hz 72.45 dB 40 dB Pass

    3817 Hz 72.41 dB 40 dB Pass

    Condition 3: Feed polarity: Normal, Series resistance: 2.05 kOhm Pass

    50 Hz 71.86 dB 40 dB Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.1.2.1 Longitudinal conversion loss

    Test purpose: To ensure that the impedance unbalance about earth, expressed as Longitudinal Conversion Loss, meets the requirements.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 2:20:04 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 17 of 70

    Frequency LCL Limit Verdict

    67 Hz 73.32 dB 40 dB Pass

    88 Hz 73.95 dB 40 dB Pass

    118 Hz 74.24 dB 40 dB Pass

    156 Hz 74.17 dB 40 dB Pass

    208 Hz 73.56 dB 40 dB Pass

    277 Hz 73.11 dB 40 dB Pass

    368 Hz 72.89 dB 40 dB Pass

    490 Hz 72.60 dB 40 dB Pass

    652 Hz 72.67 dB 46 dB Pass

    867 Hz 72.44 dB 46 dB Pass

    1152 Hz 72.70 dB 46 dB Pass

    1534 Hz 72.56 dB 46 dB Pass

    2041 Hz 72.63 dB 46 dB Pass

    2717 Hz 72.55 dB 46 dB Pass

    3623 Hz 72.46 dB 40 dB Pass

    3817 Hz 72.41 dB 40 dB Pass

    Condition 4: Feed polarity: Reverse, Series resistance: 2.8 kOhm Pass

    50 Hz 70.36 dB 40 dB Pass

    67 Hz 73.25 dB 40 dB Pass

    88 Hz 74.34 dB 40 dB Pass

    118 Hz 75.02 dB 40 dB Pass

    156 Hz 74.66 dB 40 dB Pass

    208 Hz 74.09 dB 40 dB Pass

    277 Hz 73.55 dB 40 dB Pass

    368 Hz 73.02 dB 40 dB Pass

    490 Hz 72.85 dB 40 dB Pass

    652 Hz 72.56 dB 46 dB Pass

    867 Hz 72.62 dB 46 dB Pass

    1152 Hz 72.63 dB 46 dB Pass

    1534 Hz 72.78 dB 46 dB Pass

    2041 Hz 72.75 dB 46 dB Pass

    2717 Hz 72.83 dB 46 dB Pass

    3623 Hz 72.78 dB 40 dB Pass

    3817 Hz 72.90 dB 40 dB Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.1.2.2 Output signal balance

    Test purpose: To ensure that the impedance unbalance about earth, expressed as output signal balance, meets the requirements.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 3:29:30 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15 Progress tone 1300 Hz

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 18 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Output Signal Balance in range 0 to 40 dB ±0.49dB

    Output Signal Balance in range 40 to 60 dB ±2.80dB

    General parameters

    Parameter Value

    Feed voltage 50 V

    Output signal balance vs frequency, conditions 1 to 4

    Bal

    ance

    (dB

    )

    100 1000

    0

    10

    20

    30

    40

    50

    60

    70

    80

    Frequency (Hz)

    –––– Limit

    –––– Result - Condition 1: Series resistance: 400 Ohm, Feed polarity: Normal

    –––– Result - Condition 2: Series resistance: 850 Ohm, Feed polarity: Reverse

    –––– Result - Condition 3: Series resistance: 2.05 kOhm, Feed polarity: Normal

    –––– Result - Condition 4: Series resistance: 2.8 kOhm, Feed polarity: Reverse

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.2.1 Mean sending level

    Test purpose: To check that the mean sending level in the frequency range 200 Hz to 3 800 Hz over a one-minute period is not greater than -9.7 dBV. This requirement does not apply to DTMF signals.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 3:34:00 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15 Progress tone 1300 Hz

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 19 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Signal power level (20Hz - 300kHz) ±0.1dB

    Signal power level (300kHz - 30 MHz) ±2.52dB

    Peak to peak voltage (frequency 10Hz - 5kHz) ±0.22%

    General parameters

    Parameter Value

    EUT state Sending Data

    Feed voltage 50 V

    Test ranges

    Frequency

    Start Stop Acquisition settings Termination

    200.00 Hz 3.80 kHz Acquisition time = 100 ms, Overall meas. time = 60 s

    270 Ohm + 750 Ohm ll 0.15 uF VF

    Voltage vs time, conditions 1 to 2

    Vol

    tage

    (V)

    0 2 m 4 m 6 m 8 m 10 m 12 m 14 m 16 m 18 m 20 m

    -500 m

    -400 m

    -300 m

    -200 m

    -100 m

    0

    100 m

    200 m

    300 m

    400 m

    500 m

    Time (s)

    –––– Result - Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm

    –––– Result - Condition 2: Feed polarity: Reverse, Series resistance: 2.8 kOhm

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.2.1 Mean sending level

    Test purpose: To check that the mean sending level in the frequency range 200 Hz to 3 800 Hz over a one-minute period is not greater than -9.7 dBV. This requirement does not apply to DTMF signals.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 3:34:00 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15 Progress tone 1300 Hz

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 20 of 70

    Average voltage spectrum, conditions 1 to 2

    Vol

    tage

    (dB

    V)

    1.00 k

    -120.00

    -100.00

    -80.00

    -60.00

    -40.00

    -20.00

    0.00

    Frequency (Hz)

    –––– Result - Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm

    –––– Result - Condition 2: Feed polarity: Reverse, Series resistance: 2.8 kOhm

    Average voltage

    Average voltage Limit Verdict

    Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm Pass

    -10.78 dBV -9.7 dBV Pass

    Condition 2: Feed polarity: Reverse, Series resistance: 2.8 kOhm Pass

    -10.75 dBV -9.7 dBV Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.2.2 Instantaneous voltage

    Test purpose: To check that the peak to peak voltage of the TE shall not be greater than 5V.

    Test mode: Evaluation Verdict: PASS

    Date & Time: 9/14/2008 3:46:36 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 21 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Signal power level (20Hz - 300kHz) ±0.1dB

    Signal power level (300kHz - 30 MHz) ±2.52dB

    Peak to peak voltage (frequency 10Hz - 5kHz) ±0.22%

    General parameters

    Parameter Value

    Feed voltage 50 V

    Test ranges

    Frequency

    Start Stop Acquisition settings Termination

    200.00 Hz 3.80 kHz Acquisition time = 100 ms, Overall meas. time = 60 s

    270 Ohm + 750 Ohm ll 0.15 uF VF

    Voltage vs time, conditions 1 to 2

    Vol

    tage

    (V)

    0 10 m 20 m 30 m 40 m 50 m 60 m 70 m 80 m 90 m

    -300 m

    -200 m

    -100 m

    0

    100 m

    200 m

    300 m

    Time (s)

    –––– Result - Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm

    –––– Result - Condition 2: Feed polarity: Reverse, Series resistance: 2.8 kOhm

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.2.2 Instantaneous voltage

    Test purpose: To check that the peak to peak voltage of the TE shall not be greater than 5V.

    Test mode: Evaluation Verdict: PASS

    Date & Time: 9/14/2008 3:46:36 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 22 of 70

    Max peak to peak voltage

    Peak to Peak Voltage Limit Verdict

    Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm Pass

    0.54 V 5 V Pass

    Condition 2: Feed polarity: Reverse, Series resistance: 2.8 kOhm Pass

    0.53 V 5 V Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.2.3 Sending level in a 10 Hz bandwidth

    Test purpose: To check that sending level within every 10 Hz bandwidth in the frequency range 30 Hz to 4300 Hz.

    This requirement does not apply to DTMF signals and Voice TE.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 3:49:32 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15 Progress tone 1300 Hz

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 23 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Signal power level (20Hz - 300kHz) ±0.1dB

    Signal power level (300kHz - 30 MHz) ±2.52dB

    Peak to peak voltage (frequency 10Hz - 5kHz) ±0.22%

    General parameters

    Parameter Value

    Feed voltage 50 V

    Test ranges

    Frequency

    Start Stop Acquisition settings Termination

    30.00 Hz

    4.30 kHz

    Resolution bandwidth = 10.00 Hz, Averaging interval = 100.00 ms, Overall meas. time = 30 s

    270 Ohm + 750 Ohm ll 0.15 uF VF

    Voltage vs time, conditions 1 to 2

    Vol

    tage

    (V

    )

    0 2 m 4 m 6 m 8 m 10 m 12 m 14 m 16 m 18 m 20 m

    -500 m

    -400 m

    -300 m

    -200 m

    -100 m

    0

    100 m

    200 m

    300 m

    400 m

    500 m

    Time (s)

    –––– Result - Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm

    –––– Result - Condition 2: Feed polarity: Reverse, Series resistance: 2.8 kOhm

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.2.3 Sending level in a 10 Hz bandwidth

    Test purpose: To check that sending level within every 10 Hz bandwidth in the frequency range 30 Hz to 4300 Hz.

    This requirement does not apply to DTMF signals and Voice TE.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 3:49:32 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15 Progress tone 1300 Hz

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 24 of 70

    Max voltage spectrum, conditions 1 to 2

    Vol

    tage

    (dB

    V)

    100.00 1.00 k

    -120.00

    -100.00

    -80.00

    -60.00

    -40.00

    -20.00

    0.00

    Frequency (Hz)

    –––– Limit

    –––– Result - Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm

    –––– Result - Condition 2: Feed polarity: Reverse, Series resistance: 2.8 kOhm

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.2.4.1 Sending level between 4,3 kHz and 200 KHz during DTMF dialling

    Test purpose: To check that the sending level in frequency range 4.3 kHz to 200 kHz during DTMF signaling is not greater than allowed.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 3:52:18 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 25 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Signal power level (20Hz - 300kHz) ±0.1dB

    Signal power level (300kHz - 30 MHz) ±2.52dB

    Peak to peak voltage (frequency 10Hz - 5kHz) ±0.22%

    General parameters

    Parameter Value

    Feed voltage 50 V

    Test ranges

    Frequency

    Start Stop Acquisition settings Termination

    4.30 kHz 12.00 kHz Resolution bandwidth = 300.00 Hz, Averaging interval = 100.00 ms, Overall meas. time = 20 s

    270 Ohm + 750 Ohm ll 0.15 uF VF

    12.00 kHz 200.00 kHz Resolution bandwidth = 1.00 kHz, Averaging interval = 100.00 ms, Overall meas. time = 20 s

    270 Ohm + 750 Ohm ll 0.15 uF VF

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.2.4.1 Sending level between 4,3 kHz and 200 KHz during DTMF dialling

    Test purpose: To check that the sending level in frequency range 4.3 kHz to 200 kHz during DTMF signaling is not greater than allowed.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 3:52:18 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 26 of 70

    Voltage vs time, conditions 1 to 2

    Vol

    tage

    (V

    )

    0 500 u 1 m 1.5 m 2 m 2.5 m

    -300 m

    -200 m

    -100 m

    0

    100 m

    200 m

    300 m

    Time (s)

    –––– Result - Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm

    –––– Result - Condition 2: Feed polarity: Reverse, Series resistance: 2.8 kOhm

    Max voltage spectrum, conditions 1 to 2

    Vol

    tage

    (dB

    V)

    10.00 k 100.00 k

    -100.00

    -90.00

    -80.00

    -70.00

    -60.00

    -50.00

    -40.00

    -30.00

    Frequency (Hz)

    –––– Limit

    –––– Result - Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm

    –––– Result - Condition 2: Feed polarity: Reverse, Series resistance: 2.8 kOhm

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.2.4.2 Sending level between 4,3 kHz and 200 KHz during communication

    Test purpose: To check that the sending level in frequency range 4.3 kHz to 200 kHz during communication is not greater than allowed.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 3:54:36 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15 Progress tone 1300 Hz

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 27 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Signal power level (20Hz - 300kHz) ±0.1dB

    Signal power level (300kHz - 30 MHz) ±2.52dB

    Peak to peak voltage (frequency 10Hz - 5kHz) ±0.22%

    General parameters

    Parameter Value

    Feed voltage 50 V

    Test ranges

    Frequency

    Start Stop Acquisition settings Termination

    4.30 kHz 12.00 kHz Resolution bandwidth = 300.00 Hz, Averaging interval = 100.00 ms, Overall meas. time = 20 s

    270 Ohm + 750 Ohm ll 0.15 uF VF

    12.00 kHz 200.00 kHz Resolution bandwidth = 1.00 kHz, Averaging interval = 100.00 ms, Overall meas. time = 20 s

    270 Ohm + 750 Ohm ll 0.15 uF VF

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.2.4.2 Sending level between 4,3 kHz and 200 KHz during communication

    Test purpose: To check that the sending level in frequency range 4.3 kHz to 200 kHz during communication is not greater than allowed.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 3:54:36 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15 Progress tone 1300 Hz

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 28 of 70

    Max voltage spectrum, conditions 1 to 2

    Vol

    tage

    (dB

    V)

    10.00 k 100.00 k

    -100.00

    -90.00

    -80.00

    -70.00

    -60.00

    -50.00

    -40.00

    -30.00

    -20.00

    -10.00

    Frequency (Hz)

    –––– Limit

    –––– Result - Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm

    –––– Result - Condition 2: Feed polarity: Reverse, Series resistance: 2.8 kOhm

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.2.5 Sending level from 200 kHz to 3 MHz

    Test purpose: To check that the total voltage level in a bandwidth, defined in table 1, wholly contained within the frequency range 200 kHz to 3 MHz, arising from normal operation of the TE and when terminated with ZRHF, not exceed the limits shown in table 1 and figure 1.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 3:57:04 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15 Progress tone 1300 Hz

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 29 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Signal power level (20Hz - 300kHz) ±0.1dB

    Signal power level (300kHz - 30 MHz) ±2.52dB

    General parameters

    Parameter Value

    Feed voltage 50 V

    Test ranges

    Frequency

    Start Stop Acquisition settings Termination

    200.00 kHz 500.00 kHz Resolution bandwidth = 10.00 kHz, Averaging interval = 100.00 ms, Overall meas. time = 10 s

    Zref.HF-ETSI

    500.00 kHz 2.50 MHz Resolution bandwidth = 10.00 kHz, Averaging interval = 100.00 ms, Overall meas. time = 10 s

    Zref.HF-ETSI

    2.50 MHz 3.00 MHz Resolution bandwidth = 10.00 kHz, Averaging interval = 100.00 ms, Overall meas. time = 10 s

    Zref.HF-ETSI

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.2.5 Sending level from 200 kHz to 3 MHz

    Test purpose: To check that the total voltage level in a bandwidth, defined in table 1, wholly contained within the frequency range 200 kHz to 3 MHz, arising from normal operation of the TE and when terminated with ZRHF, not exceed the limits shown in table 1 and figure 1.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 3:57:04 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15 Progress tone 1300 Hz

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 30 of 70

    Max voltage spectrum density, conditions 1 to 2

    Vol

    tage

    den

    sity

    (dB

    V/s

    qrt(H

    z))

    1.00 M

    -140

    -135

    -130

    -125

    -120

    -115

    -110

    -105

    -100

    Frequency (Hz)

    –––– Limit

    –––– Result - Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm

    –––– Result - Condition 2: Feed polarity: Reverse, Series resistance: 2.8 kOhm

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.2.5 Sending level from 200 kHz to 3 MHz

    Test purpose: To check that the total voltage level in a bandwidth, defined in table 1, wholly contained within the frequency range 200 kHz to 3 MHz, arising from normal operation of the TE and when terminated with ZRHF, not exceed the limits shown in table 1 and figure 1.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 4:00:37 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15 DTMF

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 31 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Signal power level (20Hz - 300kHz) ±0.1dB

    Signal power level (300kHz - 30 MHz) ±2.52dB

    General parameters

    Parameter Value

    Feed voltage 50 V

    Test ranges

    Frequency

    Start Stop Acquisition settings Termination

    200.00 kHz 500.00 kHz Resolution bandwidth = 10.00 kHz, Averaging interval = 100.00 ms, Overall meas. time = 10 s

    Zref.HF-ETSI

    500.00 kHz 2.50 MHz Resolution bandwidth = 10.00 kHz, Averaging interval = 100.00 ms, Overall meas. time = 10 s

    Zref.HF-ETSI

    2.50 MHz 3.00 MHz Resolution bandwidth = 10.00 kHz, Averaging interval = 100.00 ms, Overall meas. time = 10 s

    Zref.HF-ETSI

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.2.5 Sending level from 200 kHz to 3 MHz

    Test purpose: To check that the total voltage level in a bandwidth, defined in table 1, wholly contained within the frequency range 200 kHz to 3 MHz, arising from normal operation of the TE and when terminated with ZRHF, not exceed the limits shown in table 1 and figure 1.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 4:00:37 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15 DTMF

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 32 of 70

    Max voltage spectrum density, conditions 1 to 2

    Vol

    tage

    den

    sity

    (dB

    V/s

    qrt(H

    z))

    1.00 M

    -140

    -135

    -130

    -125

    -120

    -115

    -110

    -105

    -100

    Frequency (Hz)

    –––– Limit

    –––– Result - Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm

    –––– Result - Condition 2: Feed polarity: Reverse, Series resistance: 2.8 kOhm

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.2.5 Sending level from 3 MHz to 30 MHz

    Test purpose: To check that the total voltage level in a bandwidth, defined in table 1, wholly contained within the frequency range 3 MHz to 30 MHz, arising from normal operation of the TE and when terminated with ZRHF, not exceed the limits shown in table 1 and figure 1.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 4:02:06 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15 DTMF

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 33 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Signal power level (20Hz - 300kHz) ±0.1dB

    Signal power level (300kHz - 30 MHz) ±2.52dB

    General parameters

    Parameter Value

    Feed voltage 50 V

    Test ranges

    Frequency

    Start Stop RMS bandwidth

    Acquisition settings Termination

    3.00 MHz

    30.10 MHz

    1 MHz Resolution bandwidth = 10.00 kHz, Averaging interval = 100.00 ms, Overall meas. time = 10 s

    Zref.HF-ETSI

    Max voltage spectrum density, conditions 1 to 2

    Vol

    tage

    den

    sity

    (dB

    V/s

    qrt(H

    z))

    10.00 M

    -140

    -138

    -136

    -134

    -132

    -130

    -128

    -126

    -124

    -122

    -120

    Frequency (Hz)

    –––– Limit

    –––– Result - Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm

    –––– Result - Condition 2: Feed polarity: Reverse, Series resistance: 2.8 kOhm

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.2.5 Sending level from 3 MHz to 30 MHz

    Test purpose: To check that the total voltage level in a bandwidth, defined in table 1, wholly contained within the frequency range 3 MHz to 30 MHz, arising from normal operation of the TE and when terminated with ZRHF, not exceed the limits shown in table 1 and figure 1.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 4:03:27 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15 Progress tone 1300 Hz

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 34 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Signal power level (20Hz - 300kHz) ±0.1dB

    Signal power level (300kHz - 30 MHz) ±2.52dB

    General parameters

    Parameter Value

    Feed voltage 50 V

    Test ranges

    Frequency

    Start Stop RMS bandwidth

    Acquisition settings Termination

    3.00 MHz

    30.10 MHz

    1 MHz Resolution bandwidth = 10.00 kHz, Averaging interval = 100.00 ms, Overall meas. time = 10 s

    Zref.HF-ETSI

    Max voltage spectrum density, conditions 1 to 2

    Vol

    tage

    den

    sity

    (dB

    V/s

    qrt(H

    z))

    10.00 M

    -140

    -138

    -136

    -134

    -132

    -130

    -128

    -126

    -124

    -122

    -120

    Frequency (Hz)

    –––– Limit

    –––– Result - Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm

    –––– Result - Condition 2: Feed polarity: Reverse, Series resistance: 2.8 kOhm

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.3 Power feeding limitation

    Test purpose: To verify that the TE does not feed the TN interface.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 4:04:22 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 35 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Current ±1.23%

    Voltage ±1.1%

    General parameters

    Parameter Value

    Delay before meas. 5s

    Line resistance 300 Ohm

    Max voltage, Max current

    Max Voltage Max Current Limit Verdict

    Pass

    0.00 V 2.44 uA 1 mA Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.4.1 DC Resistance

    Test purpose: To check whether the TE presents a resistance of at least 4 MOhm at 25, 50 and 100 VDC in quiescent state.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 12:35:51 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 36 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Tip-Ring, Test voltage 1-200V

    Resistance in range 30 kohm - 10 Mohm ±0.8 %

    Resistance in range 10- 30 Mohm ±2.5%

    Tip, Ring to Ground, Test voltage 5-500V

    Resistance in range 30 kohm - 1 Mohm ±1%

    Resistance in range 1 Mohm - 10 Mohm ±2%

    Resistance in range 10- 30 Mohm ±2.5%

    Resistance vs voltage

    Voltage Resistance Limit Verdict

    Condition 1: Test polarity: Normal Pass

    25 V 19.36 MOhm 4 MOhm Pass

    50 V 19.63 MOhm 4 MOhm Pass

    100 V 19.71 MOhm 4 MOhm Pass

    Condition 2: Test polarity: Reverse Pass

    25 V 19.69 MOhm 4 MOhm Pass

    50 V 19.84 MOhm 4 MOhm Pass

    100 V 19.88 MOhm 4 MOhm Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.4.2.1 Impedance

    Test purpose: To determine whether the TE presents impedance in the quiescent state during ringing equal to or greater than 16 KOhm.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 12:37:22 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 37 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    DC current ±2.6%

    AC current ±0.72%

    Phase ±0.43%

    Impedance ±1.69%

    General parameters

    Parameter Value

    Series resistance 2.05 kOhm

    Ring level 30.00 Vrms

    AC Current, Impedance

    Current Impedance Limit Verdict

    Condition 1: Feed voltage: 0 V, Ring frequency: 25.00 Hz Pass

    < 50.00 uA > 600.00 kOhm 16 kOhm Pass

    Condition 2: Feed voltage: 50 V, Ring frequency: 25.00 Hz Pass

    < 50.00 uA > 600.00 kOhm 16 kOhm Pass

    Condition 3: Feed voltage: 0 V, Ring frequency: 50.00 Hz Pass

    < 50.00 uA > 600.00 kOhm 16 kOhm Pass

    Condition 4: Feed voltage: 50 V, Ring frequency: 50.00 Hz Pass

    < 50.00 uA > 600.00 kOhm 16 kOhm Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.4.2.2 Transient response

    Test purpose: To check the transient current characteristics of the TE in quiescent state. The current shall be equal to or less than 25 mA, 1 ms after commencement of the excitation, and equal to or less than 10 mA 6 ms after commencement.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 12:39:58 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 38 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Current ±1.4%

    Timing ±0.1ms

    General parameters

    Parameter Value

    Series resistance 200 Ohm

    Feed voltage 60 V

    Current vs time, conditions 1 to 2

    Cur

    rent

    (A)

    0 2 m 4 m 6 m 8 m 10 m 12 m 14 m 16 m 18 m 20 m

    0.00

    10.00 m

    20.00 m

    30.00 m

    40.00 m

    50.00 m

    Time (s)

    –––– Limit

    –––– Result - Condition 1: Feed polarity: Normal

    –––– Result - Condition 2: Feed polarity: Reverse

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.4.2.3 DC current

    Test purpose: To determine whether the DC component of the ringing current exceeds 0.6 mA

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 12:41:25 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 39 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    DC current ±2.6%

    AC current ±0.72%

    Phase ±0.43%

    Impedance ±1.69%

    General parameters

    Parameter Value

    Series resistance 850 Ohm

    Meas. configuration Tip - Ring

    Ringing signal level 90.00 Vrms

    DC Current

    Current Limit Verdict

    Condition 1: Feed polarity: Normal, Feed voltage: 60 V, Ringing frequency: 25.00 Hz Pass

    < 50.00 uA 600 uA Pass

    Condition 2: Feed polarity: Normal, Feed voltage: 60 V, Ringing frequency: 50.00 Hz Pass

    < 50.00 uA 600 uA Pass

    Condition 3: Feed polarity: Reverse, Feed voltage: 60 V, Ringing frequency: 25.00 Hz Pass

    < 50.00 uA 600 uA Pass

    Condition 4: Feed polarity: Reverse, Feed voltage: 60 V, Ringing frequency: 50.00 Hz Pass

    < 50.00 uA 600 uA Pass

    Condition 5: Feed polarity: Normal, Feed voltage: 0 V, Ringing frequency: 25.00 Hz Pass

    < 50.00 uA 600 uA Pass

    Condition 6: Feed polarity: Normal, Feed voltage: 0 V, Ringing frequency: 50.00 Hz Pass

    < 50.00 uA 600 uA Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.4.3 Resistance to earth

    Test purpose: To check whether the TE in the quiescent state presents a resistance to earth of at least 40 Mohm when tested at 100 VDC.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 12:46:44 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 40 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Tip-Ring, Test voltage 1-200V

    Resistance in range 30 kohm - 10 Mohm ±0.8 %

    Resistance in range 10- 30 Mohm ±2.5%

    Tip, Ring to Ground, Test voltage 5-500V

    Resistance in range 30 kohm - 1 Mohm ±1%

    Resistance in range 1 Mohm - 10 Mohm ±2%

    Resistance in range 10- 30 Mohm ±2.5%

    Resistance vs voltage

    Voltage Resistance Limit Verdict

    Condition 1: Test polarity: Normal, Meas. configuration: Tip - Ground Pass

    100 V > 100 MOhm 40 MOhm Pass

    Condition 2: Test polarity: Reverse, Meas. configuration: Tip - Ground Pass

    100 V > 100 MOhm 40 MOhm Pass

    Condition 3: Test polarity: Normal, Meas. configuration: Ring - Ground Pass

    100 V > 100 MOhm 40 MOhm Pass

    Condition 4: Test polarity: Reverse, Meas. configuration: Ring - Ground Pass

    100 V > 100 MOhm 40 MOhm Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.4.4 Impedance

    Test purpose: To check whether the TE presents an impedance at least 40 KOhm between 200 Hz and 4300 Hz and at least 5 KOhm at 12 kHz and 16 kHz when tested at 1 Vrms in the quiescent state.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 12:47:08 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 41 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Impedance ±3.6%

    General parameters

    Parameter Value

    Feed voltage 9 V

    Stimulus level 1 V

    Impedance vs frequency

    Impe

    danc

    e (O

    hm)

    1.00 k 10.00 k

    0.00

    20.00 k

    40.00 k

    60.00 k

    80.00 k

    100.00 k

    120.00 k

    140.00 k

    160.00 k

    Frequency (Hz)

    –––– Limit –––– Result

    Impedance vs frequency

    Frequency Impedance Limit Verdict

    Pass

    200.00 Hz > 150.00 kOhm 40 kOhm Pass

    4.30 kHz 71.68 kOhm 5 kOhm Pass

    12.05 kHz 24.50 kOhm 5 kOhm Pass

    16.13 kHz 18.31 kOhm 5 kOhm Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.5 Ringing signal detector sensitivity

    Test purpose: To determine the ability of the TE to respond as stated by the supplier to ringing signals

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 1:57:42 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 42 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Ringing voltage ±1.6%

    Ringing frequency ±0.01%

    Timing ±37ms

    General parameters

    Parameter Value

    Series resistance 850 Ohm

    Adjust ring level No

    Voltage vs time, conditions 1 to 2

    Vol

    tage

    (V

    )

    0 1 2 3 4 5 6 7 8

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    Time (s)

    –––– Result - Condition 1: Feed voltage: 50 V, Ring signal: Ring signal 25Hz/30V 1.0/5.0

    –––– Result - Condition 2: Feed voltage: 50 V, Ring signal: Ring signal 50Hz/30V 1.0/5.0

    Response time, Sensitivity

    Time Sensitivity Limit Verdict

    Condition 1: Feed voltage: 50 V, Ring signal: Ring signal 25Hz/30V 1.0/5.0 Pass

    7.22 s Sensitive Sensitive Pass

    Condition 2: Feed voltage: 50 V, Ring signal: Ring signal 50Hz/30V 1.0/5.0 Pass

    7.28 s Sensitive Sensitive Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.6.1 Acceptance of breaks in the loop in a call attempt

    Test purpose: To check the ability of the TE to accept breaks in the loop current during establishment of loop state

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 1:13:46 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 43 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Measured Current ±1.2%

    Measured Timing ±2%

    General parameters

    Parameter Value

    Series resistance 850 Ohm

    Feed voltage 50 V

    Off-hook current 0.0128A

    Break Loop Duration 400.00 ms

    Current vs time, conditions 1 to 2

    Cur

    rent

    (A

    )

    -5 0 5 10 15 20 25 30

    -10 m

    0

    10 m

    20 m

    30 m

    40 m

    50 m

    Time (s)

    –––– Result - Condition 1: Feed polarity: Normal, Delay before Break: 30.00 ms

    –––– Result - Condition 2: Feed polarity: Reverse, Delay before Break: 30.00 ms

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.6.1 Acceptance of breaks in the loop in a call attempt

    Test purpose: To check the ability of the TE to accept breaks in the loop current during establishment of loop state

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 1:13:46 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 44 of 70

    Current vs time, conditions 3 to 4

    Cur

    rent

    (A)

    -5 0 5 10 15 20 25 30

    -10 m

    0

    10 m

    20 m

    30 m

    40 m

    50 m

    Time (s)

    –––– Result - Condition 3: Feed polarity: Normal, Delay before Break: 500.00 ms

    –––– Result - Condition 4: Feed polarity: Reverse, Delay before Break: 500.00 ms

    Rise time, Drop time

    Rise time Limit Drop time Limit Verdict

    Condition 1: Feed polarity: Normal, Delay before Break: 30.00 ms Pass

    400 us 20 ms

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.6.2 Loop current characteristics

    Test purpose: To check the current/time characteristics of the TE during the transition from quiescent to loop state in various loop feeding conditions.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 1:17:37 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 45 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    DC current ±1.41%

    Timing ±0.2ms

    General parameters

    Parameter Value

    Feed polarity Normal

    Feed voltage 50 V

    If0 100.00 uA

    Current vs time, conditions 1 to 4

    Cur

    rent

    (A

    )

    0 200 m 400 m 600 m 800 m 1 1.2 1.4

    -1.00 m

    0.00

    1.00 m

    2.00 m

    3.00 m

    4.00 m

    5.00 m

    6.00 m

    7.00 m

    Time (s)

    –––– Result - Condition 1: Series resistance: 150 kOhm, t1-t0: 400 ms, t2-t01: 400.00 ms, t3-t01: 400.00 ms, If2: 300.00 uA, If1: 300.00 uA

    –––– Result - Condition 2: Series resistance: 36 kOhm, t1-t0: 400 ms, t2-t01: 400.00 ms, t3-t01: 400.00 ms, If2: 1.25 mA, If1: 1.25 mA

    –––– Result - Condition 3: Series resistance: 24 kOhm, t1-t0: 400 ms, t2-t01: 400.00 ms, t3-t01: 400.00 ms, If2: 1.86 mA, If1: 1.86 mA

    –––– Result - Condition 4: Series resistance: 8 kOhm, t1-t0: 400 ms, t2-t01: 400.00 ms, t3-t01: 400.00 ms, If2: 5.00 mA, If1: 5.00 mA

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.6.2 Loop current characteristics

    Test purpose: To check the current/time characteristics of the TE during the transition from quiescent to loop state in various loop feeding conditions.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 1:17:37 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 46 of 70

    Current vs time, conditions 5 to 6

    Cur

    rent

    (A)

    0 200 m 400 m 600 m 800 m 1 1.2 1.4 1.6 1.8 2 2.2 2.4

    -10.00 m

    0.00

    10.00 m

    20.00 m

    30.00 m

    40.00 m

    50.00 m

    60.00 m

    70.00 m

    80.00 m

    Time (s)

    –––– Result - Condition 5: Series resistance: 2.8 kOhm, t1-t0: 30 ms, t2-t01: 500.00 ms, t3-t01: 1.20 s, If2: 14.60 mA, If1: 15.00 mA

    –––– Result - Condition 6: Series resistance: 400 Ohm, t1-t0: 20 ms, t2-t01: 500.00 ms, t3-t01: 1.20 s, If2: 47.20 mA, If1: 47.20 mA

    Line seizure rise time, Total drops time

    Series resistance

    Rise time Limit Drops time Limit Verdict

    Condition 1: Series resistance: 150 kOhm, t1-t0: 400 ms, t2-t01: 400.00 ms, t3-t01: 400.00 ms, If2: 300.00 uA, If1: 300.00 uA

    Pass

    150 kOhm 20 us 400 ms < 20 us 7 ms Pass

    Condition 2: Series resistance: 36 kOhm, t1-t0: 400 ms, t2-t01: 400.00 ms, t3-t01: 400.00 ms, If2: 1.25 mA, If1: 1.25 mA

    Pass

    36 kOhm 80 us 400 ms < 20 us 7 ms Pass

    Condition 3: Series resistance: 24 kOhm, t1-t0: 400 ms, t2-t01: 400.00 ms, t3-t01: 400.00 ms, If2: 1.86 mA, If1: 1.86 mA

    Pass

    24 kOhm 80 us 400 ms < 20 us 7 ms Pass

    Condition 4: Series resistance: 8 kOhm, t1-t0: 400 ms, t2-t01: 400.00 ms, t3-t01: 400.00 ms, If2: 5.00 mA, If1: 5.00 mA

    Pass

    8 kOhm 60 us 400 ms < 20 us 7 ms Pass

    Condition 5: Series resistance: 2.8 kOhm, t1-t0: 30 ms, t2-t01: 500.00 ms, t3-t01: 1.20 s, If2: 14.60 mA, If1: 15.00 mA

    Pass

    2.8 kOhm 80 us 30 ms < 20 us 7 ms Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.6.2 Loop current characteristics

    Test purpose: To check the current/time characteristics of the TE during the transition from quiescent to loop state in various loop feeding conditions.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 1:17:37 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 47 of 70

    Series resistance

    Rise time Limit Drops time Limit Verdict

    Condition 6: Series resistance: 400 Ohm, t1-t0: 20 ms, t2-t01: 500.00 ms, t3-t01: 1.20 s, If2: 47.20 mA, If1: 47.20 mA

    Pass

    400 Ohm 60 us 20 ms < 20 us 7 ms Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.6.3 Ring trip

    Test purpose: To check that the current of the TE during the transition from quiescent to loop state comply with clause 4.6.3.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 1:25:26 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 48 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    AC current ±1.72%

    Timing ±0.43 us

    General parameters

    Parameter Value

    AC source impedance 800 Ohm

    DC feed resistance 850 Ohm

    Feed voltage 50 V

    DC hold on time 60 s

    AC On-hook current, AC Off-hook current

    AC On-hook current AC Off-hook current Limit Verdict

    Condition 1: Ring signal: Ring signal 25Hz/50V 1.0/3.0 Pass

    9.20 uA 36.11 mA 36 mA Pass

    Condition 2: Ring signal: Ring signal 50Hz/50V 1.0/3.0 Pass

    26.90 uA 36.77 mA 36 mA Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.6.4 On-Hook to Off-Hook transition with ringing without DC

    Test purpose: To check that the current / time characteristics of the TE during the transition from quiescent to loop state, for ringing without DC, when the transition occurs during a ringing pulse, comply with clause 4.6.4.

    Test mode: Evaluation Verdict: PASS

    Date & Time: 9/23/2008 8:31:29 AM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 9

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 49 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    AC current ±1.72%

    Timing ±0.43 us

    General parameters

    Parameter Value

    Feed voltage 50 V

    DC hold on time 10 s

    Off-hook limit correction 70 %

    On-hook limit correction 120.00 %

    AC Current vs time, condition 1

    Cur

    rent

    (A

    )

    0 100 m 200 m 300 m 400 m 500 m 600 m 700 m 800 m 900 m 1

    0.00

    10.00 m

    20.00 m

    30.00 m

    40.00 m

    50.00 m

    60.00 m

    Time (s)

    –––– Limit

    –––– Result - Condition 1: AC source impedance: 800 Ohm, DC feed resistance: 300 Ohm, Ring signal: Ring signal 25Hz/50V 1.0/3.0

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.6.4 On-Hook to Off-Hook transition with ringing without DC

    Test purpose: To check that the current / time characteristics of the TE during the transition from quiescent to loop state, for ringing without DC, when the transition occurs during a ringing pulse, comply with clause 4.6.4.

    Test mode: Evaluation Verdict: PASS

    Date & Time: 9/23/2008 8:31:29 AM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 9

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 50 of 70

    AC Current vs time, condition 2

    Cur

    rent

    (A)

    0 100 m 200 m 300 m 400 m 500 m 600 m 700 m 800 m 900 m 1

    0.00

    10.00 m

    20.00 m

    30.00 m

    40.00 m

    50.00 m

    60.00 m

    Time (s)

    –––– Limit

    –––– Result - Condition 2: AC source impedance: 1.7 kOhm, DC feed resistance: 2.8 kOhm, Ring signal: Ring signal 25Hz/50V 1.0/3.0

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.6.4 On-Hook to Off-Hook transition with ringing without DC

    Test purpose: To check that the current / time characteristics of the TE during the transition from quiescent to loop state, for ringing without DC, when the transition occurs during a ringing pulse, comply with clause 4.6.4.

    Test mode: Evaluation Verdict: PASS

    Date & Time: 9/23/2008 8:31:29 AM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 9

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 51 of 70

    AC Current vs time, condition 3

    Cur

    rent

    (A)

    0 100 m 200 m 300 m 400 m 500 m 600 m 700 m 800 m 900 m 1

    0.00

    10.00 m

    20.00 m

    30.00 m

    40.00 m

    50.00 m

    60.00 m

    Time (s)

    –––– Limit

    –––– Result - Condition 3: AC source impedance: 800 Ohm, DC feed resistance: 300 Ohm, Ring signal: Ring signal 50Hz/50V 1.0/3.0

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.6.4 On-Hook to Off-Hook transition with ringing without DC

    Test purpose: To check that the current / time characteristics of the TE during the transition from quiescent to loop state, for ringing without DC, when the transition occurs during a ringing pulse, comply with clause 4.6.4.

    Test mode: Evaluation Verdict: PASS

    Date & Time: 9/23/2008 8:31:29 AM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 9

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 52 of 70

    AC Current vs time, condition 4

    Cur

    rent

    (A)

    0 100 m 200 m 300 m 400 m 500 m 600 m 700 m 800 m 900 m 1

    0.00

    10.00 m

    20.00 m

    30.00 m

    40.00 m

    50.00 m

    60.00 m

    Time (s)

    –––– Limit

    –––– Result - Condition 4: AC source impedance: 1.7 kOhm, DC feed resistance: 2.8 kOhm, Ring signal: Ring signal 50Hz/50V 1.0/3.0

    AC On-hook current, AC Off-hook current

    AC On-hook current AC Off-hook current Verdict

    Condition 1: AC source impedance: 800 Ohm, DC feed resistance: 300 Ohm, Ring signal: Ring signal 25Hz/50V 1.0/3.0

    -

    3.64 mA 36.73 mA -

    Condition 2: AC source impedance: 1.7 kOhm, DC feed resistance: 2.8 kOhm, Ring signal: Ring signal 25Hz/50V 1.0/3.0

    -

    3.20 mA 20.86 mA -

    Condition 3: AC source impedance: 800 Ohm, DC feed resistance: 300 Ohm, Ring signal: Ring signal 50Hz/50V 1.0/3.0

    -

    4.94 mA 37.15 mA -

    Condition 4: AC source impedance: 1.7 kOhm, DC feed resistance: 2.8 kOhm, Ring signal: Ring signal 50Hz/50V 1.0/3.0

    -

    3.97 mA 20.90 mA -

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.7.1 DC characteristics

    Test purpose: To verify the steady-state DC loop characteristics

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 1:21:07 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 53 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Current ±1.23%

    Voltage ±1.1%

    General parameters

    Parameter Value

    Feed voltage 50 V

    Current stability 0.50%

    Setting time 3 s

    Delay after line seizure 1.20 s

    Test ranges

    Feed Resistance

    Start Stop Step

    400 Ohm 400 Ohm 0 Ohm

    850 Ohm 850 Ohm 0 Ohm

    2.05 kOhm 2.05 kOhm 0 Ohm

    2.8 kOhm 2.8 kOhm 0 Ohm

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.7.1 DC characteristics

    Test purpose: To verify the steady-state DC loop characteristics

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 1:21:07 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 54 of 70

    DC Voltage vs current, conditions 1 to 2

    Vol

    tage

    (V)

    0.00 10.00 m 20.00 m 30.00 m 40.00 m 50.00 m 60.00 m

    0.00

    5.00

    10.00

    15.00

    20.00

    25.00

    30.00

    35.00

    40.00

    Current (A)

    –––– Limit

    –––– Result - Condition 1: Feed polarity: Normal

    –––– Result - Condition 2: Feed polarity: Reverse

    DC Voltage vs current

    Current Voltage Limit Verdict

    Condition 1: Feed polarity: Normal Pass

    15.65 mA 6.19 V 9 V Pass

    21.12 mA 6.74 V 9.28 V Pass

    44.10 mA 12.40 V 21.19 V Pass

    49.33 mA 30.15 V 37.86 V Pass

    Condition 2: Feed polarity: Reverse Pass

    15.65 mA 6.17 V 9 V Pass

    21.13 mA 6.72 V 9.28 V Pass

    44.13 mA 12.37 V 21.28 V Pass

    49.37 mA 30.12 V 37.99 V Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.7.2 Impedance

    Test purpose: To verify that the return loss of the input impedance of the TE in relation to the reference impedance is not less than 6 dB at 200 - 300 Hz and not less than 8 dB at 300 - 4000 Hz.

    Test mode: Evaluation Verdict: PASS

    Date & Time: 9/14/2008 11:56:55 AM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15 (FXO-1)

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 55 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Impedance (50 to 2000 ohm) ±0.42%

    Phase (50 to 2000 ohm) ±0.5%

    Return Loss (0 to 30 dB RL) ±0.32dB

    Return Loss (30 to 40 dB RL) ±1.3dB

    General parameters

    Parameter Value

    Termination 270 Ohm + 750 Ohm ll 0.15 uF VF

    Feed voltage 50 V

    Test Voltage 316 mV

    Return loss, conditions 1 to 4

    Ret

    urn

    loss

    (dB

    )

    500 1000 1500 2000 2500 3000 3500 4000

    6.00

    8.00

    10.00

    12.00

    14.00

    16.00

    18.00

    20.00

    22.00

    24.00

    Frequency (Hz)

    –––– Limit

    –––– Result - Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm

    –––– Result - Condition 2: Feed polarity: Reverse, Series resistance: 850 Ohm

    –––– Result - Condition 3: Feed polarity: Normal, Series resistance: 2.05 kOhm

    –––– Result - Condition 4: Feed polarity: Reverse, Series resistance: 2.8 kOhm

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.7.2 Impedance

    Test purpose: To verify that the return loss of the input impedance of the TE in relation to the reference impedance is not less than 6 dB at 200 - 300 Hz and not less than 8 dB at 300 - 4000 Hz.

    Test mode: Evaluation Verdict: PASS

    Date & Time: 9/14/2008 11:56:55 AM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15 (FXO-1)

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 56 of 70

    Return loss

    Frequency Return loss Limit Verdict

    Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm Pass

    200 Hz 23.14 dB 6 dB Pass

    252 Hz 22.46 dB 6 dB Pass

    318 Hz 21.61 dB 8 dB Pass

    400 Hz 20.50 dB 8 dB Pass

    504 Hz 19.21 dB 8 dB Pass

    635 Hz 17.79 dB 8 dB Pass

    800 Hz 16.33 dB 8 dB Pass

    1008 Hz 14.89 dB 8 dB Pass

    1271 Hz 13.55 dB 8 dB Pass

    1601 Hz 12.30 dB 8 dB Pass

    2017 Hz 11.27 dB 8 dB Pass

    2542 Hz 10.53 dB 8 dB Pass

    3203 Hz 9.91 dB 8 dB Pass

    4000 Hz 9.47 dB 8 dB Pass

    Condition 2: Feed polarity: Reverse, Series resistance: 850 Ohm Pass

    200 Hz 23.36 dB 6 dB Pass

    252 Hz 22.67 dB 6 dB Pass

    318 Hz 21.77 dB 8 dB Pass

    400 Hz 20.67 dB 8 dB Pass

    504 Hz 19.38 dB 8 dB Pass

    635 Hz 17.98 dB 8 dB Pass

    800 Hz 16.55 dB 8 dB Pass

    1008 Hz 15.13 dB 8 dB Pass

    1271 Hz 13.82 dB 8 dB Pass

    1601 Hz 12.65 dB 8 dB Pass

    2017 Hz 11.60 dB 8 dB Pass

    2542 Hz 10.88 dB 8 dB Pass

    3203 Hz 10.29 dB 8 dB Pass

    4000 Hz 9.87 dB 8 dB Pass

    Condition 3: Feed polarity: Normal, Series resistance: 2.05 kOhm Pass

    200 Hz 20.70 dB 6 dB Pass

    252 Hz 20.56 dB 6 dB Pass

    318 Hz 20.12 dB 8 dB Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.7.2 Impedance

    Test purpose: To verify that the return loss of the input impedance of the TE in relation to the reference impedance is not less than 6 dB at 200 - 300 Hz and not less than 8 dB at 300 - 4000 Hz.

    Test mode: Evaluation Verdict: PASS

    Date & Time: 9/14/2008 11:56:55 AM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15 (FXO-1)

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 57 of 70

    Frequency Return loss Limit Verdict

    400 Hz 19.43 dB 8 dB Pass

    504 Hz 18.49 dB 8 dB Pass

    635 Hz 17.37 dB 8 dB Pass

    800 Hz 16.16 dB 8 dB Pass

    1008 Hz 14.91 dB 8 dB Pass

    1271 Hz 13.71 dB 8 dB Pass

    1601 Hz 12.63 dB 8 dB Pass

    2017 Hz 11.71 dB 8 dB Pass

    2542 Hz 10.97 dB 8 dB Pass

    3203 Hz 10.41 dB 8 dB Pass

    4000 Hz 10.01 dB 8 dB Pass

    Condition 4: Feed polarity: Reverse, Series resistance: 2.8 kOhm Pass

    200 Hz 20.87 dB 6 dB Pass

    252 Hz 20.61 dB 6 dB Pass

    318 Hz 20.15 dB 8 dB Pass

    400 Hz 19.43 dB 8 dB Pass

    504 Hz 18.48 dB 8 dB Pass

    635 Hz 17.35 dB 8 dB Pass

    800 Hz 16.13 dB 8 dB Pass

    1008 Hz 14.88 dB 8 dB Pass

    1271 Hz 13.68 dB 8 dB Pass

    1601 Hz 12.59 dB 8 dB Pass

    2017 Hz 11.66 dB 8 dB Pass

    2542 Hz 10.93 dB 8 dB Pass

    3203 Hz 10.37 dB 8 dB Pass

    4000 Hz 9.97 dB 8 dB Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.7.2 Reactive component of the impedance

    Test purpose: To verify that in the frequency range 200 Hz to 300 Hz, the reactive component of the impedance not exceed 500 Ohm inductive (+j 500).

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 2:06:32 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 58 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Impedance (50 to 2000 ohm) ±0.42%

    Phase (50 to 2000 ohm) ±0.5%

    Return Loss (0 to 30 dB RL) ±0.32dB

    Return Loss (30 to 40 dB RL) ±1.3dB

    General parameters

    Parameter Value

    Termination R1 + R2 || C1 R1 = 270 Ohm, R2 = 750 Ohm, C1 = 150 nF

    Feed voltage 50 V

    Test Voltage 316 mV

    Reactance series, conditions 1 to 4

    Rea

    ctan

    ce (

    Ohm

    )

    200 210 220 230 240 250 260 270 280 290 300

    -100.0

    0.0

    100.0

    200.0

    300.0

    400.0

    500.0

    Frequency (Hz)

    –––– Limit

    –––– Result - Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm

    –––– Result - Condition 2: Feed polarity: Reverse, Series resistance: 850 Ohm

    –––– Result - Condition 3: Feed polarity: Normal, Series resistance: 2.05 kOhm

    –––– Result - Condition 4: Feed polarity: Reverse, Series resistance: 2.8 kOhm

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.7.2 Reactive component of the impedance

    Test purpose: To verify that in the frequency range 200 Hz to 300 Hz, the reactive component of the impedance not exceed 500 Ohm inductive (+j 500).

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 2:06:32 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 59 of 70

    Impedance, Phase, Reactance series

    Frequency Impedance Phase Reactance Limit Verdict

    Condition 1: Feed polarity: Normal, Series resistance: 400 Ohm Pass

    200 Hz 1.10 kOhm -0.6 Deg -11.4 Ohm 500 Ohm Pass

    220 Hz 1.10 kOhm -0.3 Deg -6.2 Ohm 500 Ohm Pass

    240 Hz 1.10 kOhm -0.2 Deg -3.6 Ohm 500 Ohm Pass

    260 Hz 1.10 kOhm 0.1 Deg 0.0 Ohm 500 Ohm Pass

    280 Hz 1.10 kOhm 0.3 Deg 6.3 Ohm 500 Ohm Pass

    300 Hz 1.10 kOhm 0.6 Deg 11.1 Ohm 500 Ohm Pass

    Condition 2: Feed polarity: Reverse, Series resistance: 850 Ohm Pass

    200 Hz 1.10 kOhm -0.5 Deg -10.4 Ohm 500 Ohm Pass

    220 Hz 1.10 kOhm -0.4 Deg -7.3 Ohm 500 Ohm Pass

    240 Hz 1.10 kOhm -0.2 Deg -4.7 Ohm 500 Ohm Pass

    260 Hz 1.10 kOhm 0 Deg 0.0 Ohm 500 Ohm Pass

    280 Hz 1.09 kOhm 0.2 Deg 3.6 Ohm 500 Ohm Pass

    300 Hz 1.09 kOhm 0.4 Deg 7.8 Ohm 500 Ohm Pass

    Condition 3: Feed polarity: Normal, Series resistance: 2.05 kOhm Pass

    200 Hz 1.12 kOhm 2.6 Deg 49.9 Ohm 500 Ohm Pass

    220 Hz 1.12 kOhm 2.4 Deg 47.7 Ohm 500 Ohm Pass

    240 Hz 1.12 kOhm 2.3 Deg 45.0 Ohm 500 Ohm Pass

    260 Hz 1.12 kOhm 2.3 Deg 44.9 Ohm 500 Ohm Pass

    280 Hz 1.12 kOhm 2.3 Deg 44.8 Ohm 500 Ohm Pass

    300 Hz 1.12 kOhm 2.3 Deg 45.3 Ohm 500 Ohm Pass

    Condition 4: Feed polarity: Reverse, Series resistance: 2.8 kOhm Pass

    200 Hz 1.12 kOhm 2.1 Deg 41.2 Ohm 500 Ohm Pass

    220 Hz 1.12 kOhm 2.1 Deg 40.5 Ohm 500 Ohm Pass

    240 Hz 1.12 kOhm 2 Deg 39.1 Ohm 500 Ohm Pass

    260 Hz 1.12 kOhm 2 Deg 39.7 Ohm 500 Ohm Pass

    280 Hz 1.12 kOhm 2 Deg 39.5 Ohm 500 Ohm Pass

    300 Hz 1.12 kOhm 2.1 Deg 40.5 Ohm 500 Ohm Pass

  • Report ID: XORTEL_ES 203 021_17772.doc

    Date of Issue: 9/23/2008

    Test specification: 4.7.3 Resistance to earth

    Test purpose: To check whether the TE in the loop state presents a resistance to earth of at least 1 MOhm when tested at 100 VDC.

    Test mode: Compliance Verdict: PASS

    Date & Time: 9/14/2008 2:16:01 PM

    Temperature: 23.3 °C Air Pressure: 1008 hPa Relative Humidity: 478 % Mains Power Supply: 230 VAC, 50 Hz

    Remarks: Port 15

    Project: 17772, Xorcom Ltd., Astribank FXO module Page 60 of 70

    Measurement uncertainty

    Expanded uncertainty, k=2 (95% confidence):

    Tip-Ring, Test voltage 1-200V

    Resistance in range 30 kohm - 10 Mohm ±0.8 %

    Resistance in range 10- 30 Mohm ±2.5%

    Tip, Ring to Ground, Test voltage 5-500V

    Resistance in range 30 kohm - 1 Mohm ±1%

    Resistance in range 1 Mohm - 10 Mohm ±2%

    Resistance in range 10- 30 Mohm ±2.5%

    General parameters

    Parameter Value

    EUT state Off-hook

    Feed voltage 50 V

    Series resistance 400 Ohm

    Resistance vs voltage

    Voltage Resistance Limit Verdict

    Condition 1: Feed polarity: Normal, Test polarity: Normal, Meas. configuration: Tip - Ground

    Pass

    100 V > 100 MOhm 1 MOhm Pass

    Condition 2: Feed polarity: Reverse, Test polarity: Normal, Meas. configuration: Tip - Ground

    Pass

    100 V > 100 MOhm 1 MOhm Pass

    Condition 3: Feed polarity: Reverse, Test polarity: Reverse, Meas. configuration: Tip - Ground

    Pass

    100 V > 100 MOhm 1 MOhm Pass

    Condition 4: Feed polarity: Normal, Test polarity: Reverse, Meas. configuration: Tip - Ground

    Pass

    100 V > 100 MOhm 1 MOhm Pass

    Condition 5: Feed polarity: Normal, Test pol