x-ray survey of the atlas sct. the atlas semi-conductor tracker
TRANSCRIPT
![Page 1: X-Ray Survey of The ATLAS SCT. The ATLAS Semi-Conductor Tracker](https://reader036.vdocuments.site/reader036/viewer/2022062318/551ac53655034656628b5b7e/html5/thumbnails/1.jpg)
X-Ray Survey of
The ATLAS SCT
![Page 2: X-Ray Survey of The ATLAS SCT. The ATLAS Semi-Conductor Tracker](https://reader036.vdocuments.site/reader036/viewer/2022062318/551ac53655034656628b5b7e/html5/thumbnails/2.jpg)
The ATLAS Semi-Conductor Tracker
![Page 3: X-Ray Survey of The ATLAS SCT. The ATLAS Semi-Conductor Tracker](https://reader036.vdocuments.site/reader036/viewer/2022062318/551ac53655034656628b5b7e/html5/thumbnails/3.jpg)
Alignment Requirements
Error in Track Parameter measurements should not exceed 20%
Miss-alignment of SCT must not exceed the following tolerances
1220050SCT Wheels
1250 100SCT Barrel
Rø(μm)Z(μm)R(μm)
![Page 4: X-Ray Survey of The ATLAS SCT. The ATLAS Semi-Conductor Tracker](https://reader036.vdocuments.site/reader036/viewer/2022062318/551ac53655034656628b5b7e/html5/thumbnails/4.jpg)
Alignment Techniques
Initial X-Ray Survey
Frequency Scanning Interferometry
Track-Based Alignment Procedures
![Page 5: X-Ray Survey of The ATLAS SCT. The ATLAS Semi-Conductor Tracker](https://reader036.vdocuments.site/reader036/viewer/2022062318/551ac53655034656628b5b7e/html5/thumbnails/5.jpg)
Aims of The X-Ray Survey
Produce a map of the SCT modules Calibrate the FSI system Provide a starting point for Track
Alignment
![Page 6: X-Ray Survey of The ATLAS SCT. The ATLAS Semi-Conductor Tracker](https://reader036.vdocuments.site/reader036/viewer/2022062318/551ac53655034656628b5b7e/html5/thumbnails/6.jpg)
X-Rays and SCT Modules
SCT modules not optimised for X-Rays Wide beam used to
compensate
Beam profile sacrifices Z resolution
Strip position (Rø)
Sig
na
le
50μm
2mm
![Page 7: X-Ray Survey of The ATLAS SCT. The ATLAS Semi-Conductor Tracker](https://reader036.vdocuments.site/reader036/viewer/2022062318/551ac53655034656628b5b7e/html5/thumbnails/7.jpg)
X-ray Survey Overview
![Page 8: X-Ray Survey of The ATLAS SCT. The ATLAS Semi-Conductor Tracker](https://reader036.vdocuments.site/reader036/viewer/2022062318/551ac53655034656628b5b7e/html5/thumbnails/8.jpg)
Positioning the Scanning Head
Z – Positioning Stage
Ø - Positioning Stage
X-Ray Assembly
Optical strip reader
Laser Alignment
![Page 9: X-Ray Survey of The ATLAS SCT. The ATLAS Semi-Conductor Tracker](https://reader036.vdocuments.site/reader036/viewer/2022062318/551ac53655034656628b5b7e/html5/thumbnails/9.jpg)
Barrel Survey
Ø and Z fixed by scanning head
R found through use of stereo angle between X-Ray tubes
![Page 10: X-Ray Survey of The ATLAS SCT. The ATLAS Semi-Conductor Tracker](https://reader036.vdocuments.site/reader036/viewer/2022062318/551ac53655034656628b5b7e/html5/thumbnails/10.jpg)
End Cap Survey
Different X-Ray assembly required
Ø and Z fixed by scanning head
R found by Illuminating modules from two Z positions
Rθ1 θ2Z – axis
Z1 Z2
![Page 11: X-Ray Survey of The ATLAS SCT. The ATLAS Semi-Conductor Tracker](https://reader036.vdocuments.site/reader036/viewer/2022062318/551ac53655034656628b5b7e/html5/thumbnails/11.jpg)
Summary
X-Ray Survey is an alignment procedure for the ATLAS SCT
X-Ray trajectories follow those of actual events
The Majority of the hardware is already in place