Basic Principles ofX-Ray Inspection for BGAs
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
2/25
Nokia Internal Use Only
Increased Use of BGAs
Ball Grid Arrays - array of solderball connections underneathcomponent
Provides many advantages overleaded components
Reduced component size
Increased I/O count
Smaller footprint
Increased performancecharacteristics
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
3/25
Nokia Internal Use Only
The Problem with BGAs
How to verify a solder bondthat cannot be observed?
Hidden joints - touch up not
possible Only way to test integrity of
joints Electrical test
Look Under/Video Scope
X-Ray
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
4/25
Nokia Internal Use Only
How X-Rays Work
image
Presence or Absence of Material
wedge objectx-rays x-rays detector
imagedetectorlow density
high density material
x-raysx-rays
Differences in Material Density
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
5/25
Nokia Internal Use Only
X-ray tube generatesx-ray energy
X-rays absorbed where
density exists in
sample - remaining
x-rays pass through
& strike the detector
Detector converts
x-rays to visible light,
video camera sends
image to processor
Image Processor
enhances x-ray
images for high-
resolution viewing
The image you see
How an X-Ray System Works
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
6/25
Nokia Internal Use Only
Solder Connections Under X-Ray
Analysis
Main characteristic:
uniformity of the
connections
If X-ray shows all
connections uniformly
circular & equal in area
- good indication ofcomplete/proper reflow
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
7/25Nokia Internal Use Only
Nearly all Defects have Signatures
Bridging, missing balls, largevoids obvious
Other defects subtle
Look for pattern in distortion ofsize/shape of bond image
Operator learns to identify
defect signatures, processproblems and quickly make
adjustments
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
8/25Nokia Internal Use Only
May be due to excess
paste or flux
Improper reworkimplicated
Solder splattering due
to poor reflowconditions
Defects Identified by X-Ray: Bridging
Look Under Scope Image
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
9/25Nokia Internal Use Only
Misregistration
Result of errors in component placement
Possible issues with solder mask alignment
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
10/25Nokia Internal Use Only
Insufficient Reflow
More difficult to spot
If package misplaced,ball shape may beelliptical (easier toidentify)
Bond distribution not
consistent
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
11/25Nokia Internal Use Only
Can occur in
manufacturing process
Usually due tomishandling
Missing Balls
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
12/25Nokia Internal Use Only
Cold Solder
More difficult to identify
Signified by jagged
irregular edge around
the perimeter of the
solder ball
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
13/25Nokia Internal Use Only
Solder Voids
Result of moisture in
BGA packagemust be
thoroughly baked out
Problems with solder
paste
Huge issue with lead-
free solder
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
14/25Nokia Internal Use Only
Voids a process indicator,
not defect unless excessively
large
Motorola Study - balls that
contain voids up to 24%
more reliable than those
without voids!
Solder Voids
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
15/25Nokia Internal Use Only
At 70 kV
Associated with camera usedin many X-ray systems
As voltage increased, void
artificially appears to expand(bloom)At 50 kV
Makes void appear larger
than it really is Glenbrook systems not
subject to voltage blooming
Solder Voids & Voltage Blooming
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
16/25Nokia Internal Use Only
Potato Chipping/Popcorning
BGAs outside edge lifts
up from a pad
Center joints squashed
due to compressionunder die area
Caused by moisture in
BGA or excessivetopside temperature
Normal
Potato Chipping
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
17/25Nokia Internal Use Only
Note distortion/ warpage of
ball bonds lower right
corner
View through Look-Under
scope. Note package
peeling away from solderball
Potato Chipping/Popcorning
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
18/25Nokia Internal Use Only
Opens (require angled viewing)
Ball smaller thanadjacent balls
Pad shadow seen below
indicating no contactbetween ball & pad
Note two unattachedspherical shapes unlikeoval shapes adjacent to it indicate no contact
between pad & solder ball
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
19/25Nokia Internal Use Only
RTX-113HV X-Ray Inspection System
Features powerful 80 kVX-ray tube
GTI-5000 image processor
with auto-BGA analysissoftware
Sees through densemultilayer PCBs & metal
capped BGAs
Variable Angle Viewingallows for 45 degree viewing
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
20/25Nokia Internal Use Only
GTI-5000 Image Processing Software
Provides analysis of BGA
defects: bridging, voids,
missing balls
Measures BGA ball size,
ball roundness & void size
Software identifies any ball outside of set tolerance
Includes CPU, Frame Grabber, Software, Color
Monitor
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
21/25Nokia Internal Use Only
Variable Angled Viewing
Allows for 45 degree viewing
X-Ray source is rotated
Allows inspection for fullrange of hidden BGA defects: Missing or mis-registered
solder spheres
Misalignments Gross solder voids
Non-wetting or non-contact
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
22/25
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
23/25Nokia Internal Use Only
Other Real-Time X-Ray Inspection Systems
from Glenbrook Technologies
JewelBox Series
80 or 90kV
5-7, or 10 micron FocalSpot size
7x-2000x magnification
5 Axis, 360oPositioner
RTX-113
35-52kV
20 line pairs/mmresolution (up to 100optional)
Variable Angle Viewingoption available
RTX-Mini
40kV
20 line pairs/mmresolution
Truly Portablecanbe hand carried orshipped!
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
24/25Nokia Internal Use Only
11 Emery Ave
Randolph, NJ 07869
Tele: (973) 361-8866
Fax: (973) 361-9286
www.glenbrooktech.com
Manufacturers RepAaron Caplan
1310 E. Maple AveSterling, VA 20164
(703) [email protected]
www.gsaservice.com
-
8/13/2019 X-Ray Inspection BGA Glenbrook Technologies
25/25
11 Emery Ave
Randolph, NJ 07869
Tele: (973) 361-8866
Fax: (973) 361-9286
www.glenbrooktech.com
Manufacturers RepAaron Caplan
1310 E. Maple AveSterling, VA 20164
(703) [email protected]
www.gsaservice.com