primary

6

Upload: others

Post on 16-Oct-2021

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Primary
Page 2: Primary
Page 3: Primary

1A2

1A1

1A3

1A4

103

104

101

102

A-01-101

5

A-01-101

3

A-01-101

4

A-01-101

6

41'-4"

30

'-0

"

(FIELD VERIFY)

(F

IE

LD

V

ER

IF

Y)

2'-6

"

2'-6"

Primary

Sludge Pump

Station No. 1

101 102

A

A A

103

A

104

3'-6

"

3'-6

"

EQ

EQ

PR

IN

TE

D: 11/2/2018 @

8:24A

M

FILE

N

AM

E: G

:\4649-T

ow

nB

ranchT

hick\W

orking D

raw

ings\A

utoC

AD

\4649-A

-01-101.dw

g

DATE:

SCALE:

SHEET NO.

TO

WN

B

RA

NC

H W

WT

P T

HIC

KE

NIN

G P

RO

CE

SS

U

PG

RA

DE

S

LE

XIN

GT

ON

-F

AY

ET

TE

U

RB

AN

C

OU

NT

Y G

OV

ER

NM

EN

T

DE

SIG

NE

D:

DR

AW

N:

RE

VIE

WE

D:

AP

PR

OV

ED

:

DA

TE

BY

DE

SC

RIP

TIO

NN

O.

RE

VIS

IO

NS

SC

AL

E C

HE

CK

:T

HIS

M

AR

K S

HO

UL

D M

EA

SU

RE

E

XA

CT

LY

1

" W

HE

N P

LO

TT

ED

CLIE

NT

P

RO

JE

CT

N

O.

GR

W P

RO

JE

CT

N

O. 4649

AL

L R

IG

HT

S R

ES

ER

VE

D:

TH

IS

D

OC

UM

EN

T IS

T

HE

P

RO

PE

RT

Y O

F

GR

W E

NG

IN

EE

RS

, IN

C. A

ND

S

HA

LL

N

OT

BE

R

EP

RO

DU

CE

D IN

W

HO

LE

O

R IN

P

AR

T

OR

U

SE

D F

OR

C

ON

ST

RU

CT

IO

N O

F

OT

HE

R T

HA

N T

HIS

S

PE

CIF

IC

P

RO

JE

CT

WIT

HO

UT

W

RIT

TE

N P

ER

MIS

SIO

N

OCTOBER, 2018

BID

S

ET

engi

neer

inga

rchi

tect

ureg

eosp

atia

l

PLO

TT

ED

B

Y: bgoodw

in ww

w.g

rwin

c.co

m

A-01-101

1/4" = 1'

RD

H

RD

H

RD

H

--

PR

IM

AR

Y S

LU

DG

E P

UM

PIN

G S

TA

TIO

N N

O. 1

AR

CH

IT

EC

TU

RA

L P

LA

NS

SHEET KEYNOTES:

D ROOF DEMOLITION: REMOVE LIGHTNING PROTECTION

SYSTEM AND RETAIN FOR RE-INSTALLATION. REMOVE

ALL LAYERS OF THE EXISTING ROOF DOWN TO THE

CONCRETE DECK. INSPECT CONCRETE ROOF DECK

AND REPAIR AS NEEDED FOR NEW ROOF

INSTALLATION.

NEW WORK:

1. PRIME CONCRETE DECK AND INSTALL TAPERED

POLYISOCYANURATE INSULATION.

2. INSTALL SBS MODIFIED BITUMEN BASE SHEET AND

CAP SHEET

3. RE-INSTALL LIGHTNING PROTECTION SYSTEM. (TYP.

AT PERIMETER AND ALL STACKS, FANS AND UNITS)

4. INSTALL BOOT FLASHING FOR EXISTING PIPE/VENT

ROOF PENETRATION (SEE EXISTING CONDITIONS AND

MECH/PLUMBING DRAWINGS FOR EXACT QUANTITY

AND LOCATIONS)

5. INSTALL CURB FLASHING FOR EXISTING ROOF

PENETRATION (SEE EXISTING CONDITIONS AND

MECH/PLUMBING DRAWINGS FOR EXACT QUANTITY

AND LOCATIONS)

6. REMOVE EXISTING DOOR AND ALL ASSOCIATED

HARDWARE. INSTALL NEW INSULATED FRP DOOR TO

MATCH EXISTING FRAME OPENING. INSTALL NEW

DOOR HARDWARE TO MATCH EXISTING SET AND

FUNCTION.SEE DOOR SCHEDULE ON SHEET A-00-601.

7. REMOVE EXISTING ALUMINUM WINDOW UNIT. CLEAN

ALL CAULK AND PREP OPENING FOR NEW UNIT.

INSTALL NEW THARMALLY BROKEN ALUMINUM

WINDOW UNIT W/ INSULATED GALZING TO MATCH

EXISTING OPENING. CAULK INSIDE AND OUTSIDE

(TYP)

8. EXISTING WINDOW OPENING WITH WINDOW AIR

CONDITIONING UNIT TO REMAIN.

9. (NOTE NOT USED THIS BUILDING)

10. NEW 42-INCH HIGH TWO-RAIL GUARD RAIL ANCHORED

TO DECK. EXTEND ENDS OF GUARD RAIL 30-INCHES

BEYOND LIMITS OF ROOFTOP EQUIPMENT. SEE

DETAIL 7/A-01-101 FOR NOTES AND DIMENSIONS.

6

SCALE: 1/4"=1'-0"

0 4' 8'2'

1

FLOOR PLAN

PLAN

NORTH

SCALE: 1/4"=1'-0"

0 4' 8'2'

2

ROOF PLAN

PLAN

NORTH

SCALE: 1/4"=1'-0"

0 4' 8'2'

3

SOUTH ELEVATION

SCALE: 1/4"=1'-0"

0 4' 8'2'

4

EAST ELEVATION

SCALE: 1/4"=1'-0"

0 4' 8'2'

5

NORTH ELEVATION

SCALE: 1/4"=1'-0"

0 4' 8'2'

6

WEST ELEVATION

87

6

6

8

7

6

7

7

5

5

5

4

4

4 4

4

4

4

4

3

1

D

2

TYPICAL

TYPICAL

TYPICAL

TYPICAL

687

7 7

6

6

6

7 8

10

10

SCALE: 1/2"=1'-0"

0 2' 4'1'

7

DETAIL AT GUARD RAIL

1A

DD

EN

DU

M N

O. 1

11

/2

/2

01

8D

RH

1

1

1

AutoCAD SHX Text
EXISTING ROOF DRAIN
AutoCAD SHX Text
NOTE: GUARD RAILS ARE REQUIRED AT NEW OR REPLACEMENT ROOFTOP : GUARD RAILS ARE REQUIRED AT NEW OR REPLACEMENT ROOFTOP UNITS PLACED WITHING TEN FEET OF OUTSIDE EDGE OF COPING. GUARD RAILS SHALL BE 42-INCHES HIGH ABOVE HIGHEST ADJACENT WALKING SURFACE. RAIL LENGTHS SHALL EXTEND MINIMUM OF 30-INCHES BEYOND END OF EQUIPMENT (TYP)
Page 4: Primary

201

203

202

A-02-101

5

A-02-101

3

A-02-101

6

39'-8"

(FIELD VERIFY)

15'-4"

(F

IE

LD

V

ER

IF

Y)

2'-6"

2'-6"

Primary

Sludge Pump

Station No. 2

201

201

PR

IN

TE

D: 11/2/2018 @

8:29A

M

FILE

N

AM

E: G

:\4649-T

ow

nB

ranchT

hick\W

orking D

raw

ings\A

utoC

AD

\4649-A

-02-101.dw

g

DATE:

SCALE:

SHEET NO.

TO

WN

B

RA

NC

H W

WT

P T

HIC

KE

NIN

G P

RO

CE

SS

U

PG

RA

DE

S

LE

XIN

GT

ON

-F

AY

ET

TE

U

RB

AN

C

OU

NT

Y G

OV

ER

NM

EN

T

DE

SIG

NE

D:

DR

AW

N:

RE

VIE

WE

D:

AP

PR

OV

ED

:

DA

TE

BY

DE

SC

RIP

TIO

NN

O.

RE

VIS

IO

NS

SC

AL

E C

HE

CK

:T

HIS

M

AR

K S

HO

UL

D M

EA

SU

RE

E

XA

CT

LY

1

" W

HE

N P

LO

TT

ED

CLIE

NT

P

RO

JE

CT

N

O.

GR

W P

RO

JE

CT

N

O. 4649

AL

L R

IG

HT

S R

ES

ER

VE

D:

TH

IS

D

OC

UM

EN

T IS

T

HE

P

RO

PE

RT

Y O

F

GR

W E

NG

IN

EE

RS

, IN

C. A

ND

S

HA

LL

N

OT

BE

R

EP

RO

DU

CE

D IN

W

HO

LE

O

R IN

P

AR

T

OR

U

SE

D F

OR

C

ON

ST

RU

CT

IO

N O

F

OT

HE

R T

HA

N T

HIS

S

PE

CIF

IC

P

RO

JE

CT

WIT

HO

UT

W

RIT

TE

N P

ER

MIS

SIO

N

OCTOBER, 2018

BID

S

ET

engi

neer

inga

rchi

tect

ureg

eosp

atia

l

PLO

TT

ED

B

Y: bgoodw

in ww

w.g

rwin

c.co

m

A-02-101

1/4" = 1'

RD

H

RD

H

RD

H

--

PR

IM

AR

Y S

LU

DG

E P

UM

PIN

G S

TA

TIO

N N

O. 2

AR

CH

IT

EC

TU

RA

L P

LA

NS

PLAN

NORTH

SCALE: 1/4"=1'-0"

0 4' 8'2'

1

FLOOR PLAN

SCALE: 1/4"=1'-0"

0 4' 8'2'

2

ROOF PLAN

SCALE: 1/4"=1'-0"

0 4' 8'2'

3

SOUTH ELEVATION

SCALE: 1/4"=1'-0"

0 4' 8'2'

4

EAST ELEVATION

SCALE: 1/4"=1'-0"

0 4' 8'2'

5

NORTH ELEVATION

SCALE: 1/4"=1'-0"

0 4' 8'2'

6

WEST ELEVATION

PLAN

NORTH

SHEET KEYNOTES:

D ROOF DEMOLITION: REMOVE LIGHTNING PROTECTION

SYSTEM AND RETAIN FOR RE-INSTALLATION. REMOVE

ALL LAYERS OF THE EXISTING ROOF DOWN TO THE

CONCRETE DECK. INSPECT CONCRETE ROOF DECK

AND REPAIR AS NEEDED FOR NEW ROOF

INSTALLATION.

NEW WORK:

1. PRIME CONCRETE DECK AND INSTALL TAPERED

POLYISOCYANURATE INSULATION.

2. INSTALL SBS MODIFIED BITUMEN BASE SHEET AND

CAP SHEET

3. RE-INSTALL LIGHTNING PROTECTION SYSTEM. (TYP.

AT PERIMETER AND ALL STACKS, FANS AND UNITS)

4. INSTALL BOOT FLASHING FOR EXISTING PIPE/VENT

ROOF PENETRATION (SEE EXISTING CONDITIONS AND

MECH/PLUMBING DRAWINGS FOR EXACT QUANTITY

AND LOCATIONS)

5. INSTALL CURB FLASHING FOR EXISTING ROOF

PENETRATION (SEE EXISTING CONDITIONS AND

MECH/PLUMBING DRAWINGS FOR EXACT QUANTITY

AND LOCATIONS)

6. REMOVE EXISTING DOOR AND ALL ASSOCIATED

HARDWARE. INSTALL NEW INSULATED FRP DOOR TO

MATCH EXISTING FRAME OPENING. INSTALL NEW

DOOR HARDWARE TO MATCH EXISTING SET AND

FUNCTION.SEE DOOR SCHEDULE ON SHEET A-00-601.

7. (NOTE NOT USED THIS BUILDING)

8. (NOTE NOT USED THIS BUILDING)

9. (NOTE NOT USED THIS BUILDING)

10. NEW 42-INCH HIGH TWO-RAIL GUARD RAIL ANCHORED

TO DECK. EXTEND ENDS OF GUARD RAIL 30-INCHES

BEYOND LIMITS OF ROOFTOP EQUIPMENT. SEE

DETAIL 7/A-01-101 FOR NOTES AND DIMENSIONS.

2

2

2

6

6

5

4

4

4

4

4

4

3

D

1

2

TYPICAL

TYPICAL

TYPICAL

TYPICAL

10

10

1A

DD

EN

DU

M N

O. 1

11

/2

/2

01

8D

RH

1

1

AutoCAD SHX Text
EXISTING ROOF DRAIN
Page 5: Primary

304

A-03-101

6

A-03-101

3

A-03-101

4

A-03-101

5

303

301

302

305

306

3B23B3

3B4

3B1

36'-4"

(F

IE

LD

V

ER

IF

Y)

45'-8"

(FIELD VERIFY)

2'-6"

2'-6"

2'-6"

2'-6"

2'-6"

2'-6"

B

303

B

B B

301 302

PR

IN

TE

D: 11/2/2018 @

8:33A

M

FILE

N

AM

E: G

:\4649-T

ow

nB

ranchT

hick\W

orking D

raw

ings\A

utoC

AD

\4649-A

-03-101.dw

g

DATE:

SCALE:

SHEET NO.

TO

WN

B

RA

NC

H W

WT

P T

HIC

KE

NIN

G P

RO

CE

SS

U

PG

RA

DE

S

LE

XIN

GT

ON

-F

AY

ET

TE

U

RB

AN

C

OU

NT

Y G

OV

ER

NM

EN

T

DE

SIG

NE

D:

DR

AW

N:

RE

VIE

WE

D:

AP

PR

OV

ED

:

DA

TE

BY

DE

SC

RIP

TIO

NN

O.

RE

VIS

IO

NS

SC

AL

E C

HE

CK

:T

HIS

M

AR

K S

HO

UL

D M

EA

SU

RE

E

XA

CT

LY

1

" W

HE

N P

LO

TT

ED

CLIE

NT

P

RO

JE

CT

N

O.

GR

W P

RO

JE

CT

N

O. 4649

AL

L R

IG

HT

S R

ES

ER

VE

D:

TH

IS

D

OC

UM

EN

T IS

T

HE

P

RO

PE

RT

Y O

F

GR

W E

NG

IN

EE

RS

, IN

C. A

ND

S

HA

LL

N

OT

BE

R

EP

RO

DU

CE

D IN

W

HO

LE

O

R IN

P

AR

T

OR

U

SE

D F

OR

C

ON

ST

RU

CT

IO

N O

F

OT

HE

R T

HA

N T

HIS

S

PE

CIF

IC

P

RO

JE

CT

WIT

HO

UT

W

RIT

TE

N P

ER

MIS

SIO

N

OCTOBER, 2018

BID

S

ET

engi

neer

inga

rchi

tect

ureg

eosp

atia

l

PLO

TT

ED

B

Y: bgoodw

in ww

w.g

rwin

c.co

m

A-03-101

1/4" = 1'

RD

H

RD

H

RD

H

---

GR

AV

IT

Y T

HIC

KE

NE

RS

B

UILD

IN

G P

LA

N

AR

CH

IT

EC

TU

RA

L P

LA

NS

6

SCALE: 1/4"=1'-0"

0 4' 8'2'

1

FLOOR PLAN

PLAN

NORTH

SCALE: 1/4"=1'-0"

0 4' 8'2'

2

ROOF PLAN

PLAN

NORTH

SCALE: 1/4"=1'-0"

0 4' 8'2'

3

SOUTH ELEVATION

SCALE: 1/4"=1'-0"

0 4' 8'2'

4

WEST ELEVATION

SCALE: 1/4"=1'-0"

0 4' 8'2'

5

EAST ELEVATION

SCALE: 1/4"=1'-0"

0 4' 8'2'

6

NORTH ELEVATION

SHEET KEYNOTES:

D ROOF DEMOLITION: REMOVE LIGHTNING PROTECTION

SYSTEM AND RETAIN FOR RE-INSTALLATION. REMOVE

ALL LAYERS OF THE EXISTING ROOF DOWN TO THE

CONCRETE DECK. INSPECT CONCRETE ROOF DECK

AND REPAIR AS NEEDED FOR NEW ROOF

INSTALLATION.

NEW WORK:

1. PRIME CONCRETE DECK AND INSTALL TAPERED

POLYISOCYANURATE INSULATION.

2. INSTALL SBS MODIFIED BITUMEN BASE SHEET AND

CAP SHEET

3. RE-INSTALL LIGHTNING PROTECTION SYSTEM. (TYP.

AT PERIMETER AND ALL STACKS, FANS AND UNITS)

4. INSTALL BOOT FLASHING FOR EXISTING PIPE/VENT

ROOF PENETRATION (SEE EXISTING CONDITIONS AND

MECH/PLUMBING DRAWINGS FOR EXACT QUANTITY

AND LOCATIONS)

5. INSTALL CURB FLASHING FOR EXISTING ROOF

PENETRATION (SEE EXISTING CONDITIONS AND

MECH/PLUMBING DRAWINGS FOR EXACT QUANTITY

AND LOCATIONS)

6. REMOVE EXISTING DOOR AND ALL ASSOCIATED

HARDWARE. INSTALL NEW INSULATED FRP DOOR TO

MATCH EXISTING FRAME OPENING. INSTALL NEW

DOOR HARDWARE TO MATCH EXISTING SET AND

FUNCTION.SEE DOOR SCHEDULE ON SHEET A-00-601.

7. REMOVE EXISTING ALUMINUM WINDOW UNIT. CLEAN

ALL CAULK AND PREP OPENING FOR NEW UNIT.

INSTALL NEW THARMALLY BROKEN ALUMINUM

WINDOW UNIT W/ INSULATED GALZING TO MATCH

EXISTING OPENING. CAULK INSIDE AND OUTSIDE

(TYP)

8. EXISTING WINDOW OPENING WITH WINDOW AIR

CONDITIONING UNIT TO REMAIN.

9. EXISTING OVERHEAD DOOR TO REMAIN

10. NEW 42-INCH HIGH TWO-RAIL GUARD RAIL ANCHORED

TO DECK. EXTEND ENDS OF GUARD RAIL 30-INCHES

BEYOND LIMITS OF ROOFTOP EQUIPMENT. SEE

DETAIL 7/A-01-101 FOR NOTES AND DIMENSIONS.

7

7

6

77

6

6

D

1

2

TYPICAL

TYPICAL

TYPICAL

6

6

9

9

6

6

6

7

7

7

5

4

4

4

4

4

5

5

5

3 TYPICAL

10

10

10

10

1A

DD

EN

DU

M N

O. 1

11

/2

/2

01

8D

RH

1

1

1

AutoCAD SHX Text
EXISTING ROOF DRAIN
AutoCAD SHX Text
EXISTING ROOF DRAIN
Page 6: Primary