winmag plus v6 - honeywell · • access control • video surveillance • building automation •...

8
WINMAG PLUS is a PC based management system, a technology specifically designed to meet high security, integration, workflows for integrators and end users. WINMAG plus manages and controls the following applications under one common interface: Intrusion Fire Video Access control Rescue route technology Escape door control Building management systems Public address and Voice evacuation Open Technology such as OPC and BACNET HTML WINMAG plus v6.2 sets new standards in functionality, flexibility and quality. The large installed base around the globe demonstrates its outstanding quality and high customer satisfaction. Messages are displayed graphically in 2D / 3D and in text form. Due to the open system architecture and customization abilities WINMAG plus adapts dynamically to changes in a connected system. WINMAG plus is a highly scalable solution, and existing options can be easily expanded to include, for example, access control or video. The integration of an existing or planned building management system including analogue values can be easily implemented with WINMAG plus. Already existing security systems by other manufacturers can be seamlessly integrated into WINMAG plus. When the network and the requirements grow, WINMAG plus can be expanded to accommodate them. This ensures that you are investing in a reliable system for the future. A reliable and effective alarm management system is an absolute necessity in the industrial and public sector. Alarm management system WINMAG PLUS V6.2 Alarm management system with new design. PERFORMANCE FEATURES AT A GLANCE • Modular designed alarm management software for security • Visualization of messages • Direct control of connected hardware in the network • Workflow management for security guards • Individual assignment of user rights • Integrated simulation functions • Comprehensive recording of events and operations • Automated report generation • Integration of video sequences • Time programs/calendar function • Default with integrated database BENEFITS WINMAG plus adapts to customer processes Investment protection for existing components by easily integrating them into the WINMAG plus eco-system Extend the system by adding the desired options to the existing license Unique in the market by displaying and interacting with 3D models Seamless integration with existing Third Party systems, and easy future additions

Upload: others

Post on 20-Jul-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: WINMAG PLUS V6 - Honeywell · • Access Control • Video Surveillance • Building Automation • Escape Route • PAVA • Building Management Systems (OPC or BACnet interfaces)

WINMAG PLUS is a PC based management system, a technology specifically designed to meet high security, integration, workflows for integrators and end users.

WINMAG plus manages and controls the following applications under one common interface:

Intrusion

Fire

Video

Access control

Rescue route technology

Escape door control

Building management systems

Public address and Voice evacuation

Open Technology such as OPC and BACNET

HTML

WINMAG plus v6.2 sets new standards in functionality, flexibility and quality. The large installed base around the globe demonstrates its outstanding quality and high customer satisfaction.

Messages are displayed graphically in 2D / 3D and in text form.

Due to the open system architecture and customization abilities WINMAG plus adapts dynamically to changes in a connected system. WINMAG plus is a highly scalable solution, and existing options can be easily expanded to include, for example, access control or video.

The integration of an existing or planned building management system including analogue values can be easily implemented with WINMAG plus.

Already existing security systems by other manufacturers can be seamlessly integrated into WINMAG plus. When the network and the requirements grow, WINMAG plus can be expanded to accommodate them. This ensures that you are investing in a reliable system for the future.

A reliable and effective alarm management system is an absolute necessity in the industrial and public sector.

Alarm management system

WINMAG PLUS V6.2Alarm management system with new design.

PERFORMANCE FEATURES AT A GLANCE

• Modulardesignedalarmmanagementsoftwareforsecurity

• Visualizationofmessages

• Directcontrolofconnectedhardwareinthenetwork

• Workflowmanagementforsecurityguards

• Individualassignmentofuserrights

• Integratedsimulationfunctions

• Comprehensiverecordingofeventsandoperations

• Automatedreportgeneration

• Integrationofvideosequences

• Timeprograms/calendarfunction

• Defaultwithintegrateddatabase

BENEFITS

•WINMAG plus adapts to customer processes

• Investment protection for existing components by easily integrating them into the WINMAG plus eco-system

• Extend the system by adding the desired options to the existing license

• Unique in the market by displaying and interacting with 3D models

• Seamless integration with existing Third Party systems, and easy future additions

Page 2: WINMAG PLUS V6 - Honeywell · • Access Control • Video Surveillance • Building Automation • Escape Route • PAVA • Building Management Systems (OPC or BACnet interfaces)

HUMANS ARE VISUAL BEINGS

The ability to visually assess communications

enables rapid data processing and the

implementation of prompt and target-oriented

interactions.

In the area of highly sensitive security

management, there is an urgent need to

receive information in a visual format on the

current status from all areas of the monitored

systems.

With that in view, WINMAG plus provides an

innovative, user-friendly and easily

customizable user interface with a wide range

of standards functions, e.g.:

•Alarmstack

•Prioritycontrol

•Individualworkflowsandoperations

•Macrofunctionsenableautomaticback-

ground processes without user intervention

•Flexible,window-orientedgraphics

•Varioustypesofuserrights

•ConnectionofsystemsoverstandardPC

interfaces, e.g. TCP/IP, serial port

•Openinterfacetovarioussystems

•ConnectingmodulestoThirdPartyproducts

(control panels, video matrices, building

management system)

•Individualalarmhandlingandevaluation

WINMAG plus can receive data from various

networks, process them and then display in a

customizable way:

•Graphicswithdynamicsymbols

•Tables

•Individualworkflows(alarmprograms)

•Windowsdefaultprinterusedoneach

workstation

•Loggingindatabaseandfiles

WINMAG plus data is stored in a protected,

encoded database.

WINMAG plus incorporates a global editing

environment and a variety of predefined work

flows.

MODULAR DESIGN FOR INDIVIDUAL SOLUTIONS

Thanks to its modular design, WINMAG plus

offers the appropriate solutions for every size

of system and for every area of application.

Ranging from WINMAG plus standard

package for single stations systems to multi-

station systems with incorporation of various

networks.

The WINMAG plus software is designed

modular and has several license options. The

base for WINMAG plus is the installation DVD.

This DVD includes also a demo version.

The base licence enables activation of the

standard package or the demo version to run as

unlimited visualization software on the server

workstations and on clients in the network.

The individual options can be ordered

seperately as an addition to the standard

licence.

Page 3: WINMAG PLUS V6 - Honeywell · • Access Control • Video Surveillance • Building Automation • Escape Route • PAVA • Building Management Systems (OPC or BACnet interfaces)

Thealarmwindow

Everyalarmworkflowisexecutedinaseparatewindow.Thewidgetsareusedtocontrolthealarmprogramflow.

Upto10alarmprogramscanbeprocessedsimultaneouslyandindependently.Thealarmstackcancopewithupto1000workflowsthataresorteddynamicallyaccordingtopriority.Thedesignandappearanceofanalarmprogramiscustomizableandcanbeadaptedtoendcustomerprocesses.

3Dintegrationasanoption

The3Doptionallowsuseof3Dmodelsofthecommonlyusedformatsforimproveddisplayofalarmandstatusinformation.

Anintegrationintotheoverviewwindowaswellasaseparatedisplayinadetailedviewincaseofanalarmispossible.Thepresentationofthemodelcanbedoneasfullviewandasadetailedviewdependingontherequirements.

The3Dviewallowsanoptimalthree-dimensionalvisualizationoftheoverallsituationinsideabuildingbasedontherespectiveuserrights.

Thestandardview

Aspecialformofthegraphicbackgroundwindowisthe“Standardview”.WINMAGpluscanbedisplayedasafullscreenorasawindowonthedesktop.TheWINMAGplusprogramseparatestheprogramwindowintoseveralviews.Theprogrambackgroundcanbecustomizedaccordinglytothecustomerspecification.WINMAGplusisenabledfor“Multi-monitors”usageandsupportsupto4monitors.

Page 4: WINMAG PLUS V6 - Honeywell · • Access Control • Video Surveillance • Building Automation • Escape Route • PAVA • Building Management Systems (OPC or BACnet interfaces)

Thegraphicswindow

Enablesthedisplaygraphicsinagraphictreeaswellastheintegrationofactiveanddynamicgraphicsintoabasicgraphic(graphicingraphic).Itisusedtodisplaysymbolsincludingdynamicdisplayofdetectorsandsystemfeatures.Itallowsthestartingofmacrosorpop-upprogramsonleftorrightmouseclicksonasymbol.Displayof“QuickInformation”forgraphicreferencesandsymbols.

Themultiviewwindow

Enablesthedisplayofupto12windowsonamonitor.Allwindowsaredisplayedinasplitviewnexttoeachanotherandhavethesamesize.Automaticzoomingofgraphicstofittothesizeoftheoriginwindowisincluded.Theexampleshowsawindowincludingalivevideostream.

Systemconfigurationwindow

The“SystemConfiguration”containsfunctionsfortheconfigurationofnetworks,objects,I/Odevices,types,alarmreasons,symbols,users,menubars,printersettingsandsystemsettings.Basedontheuserrightsonlytheappropriateconfigurationsettingsaredisplayed.

Page 5: WINMAG PLUS V6 - Honeywell · • Access Control • Video Surveillance • Building Automation • Escape Route • PAVA • Building Management Systems (OPC or BACnet interfaces)

•Freeprogrammability

•Flexible,window-orientedgraphics

•Displayandlocationofdetectorsingraphics

•Displayofactualsituation

•Polygongraphicreferences

•SupportofAutoCADdrawings

•StartofotherprogramsfromWINMAGplus

•High-performanceprogramminglanguage

SIAS for customer-specific adaptation of

internal processes

•RemotecontrolviamodemorISDNpossible

•AccesstootherdatabasesviaODBC

•Honeywellsystemscanbeintegrated-

ESSER, Gent, Notifier, XTRALIS, Galaxy

Dimension

•IntegrationofVAPA-SystemsVARIODYND1

•IntegrationwithHoneywellMAXPRO

VMS, Fusion 4, HRDP, HeiTel, Milestone,

Geutebrück and Dallmeier

•IntegrationoftransmissiondevicesDS6750

(IP/PSTN)orDS7700(IP/ISDN)fordirect

connection to external systems

•IntegrationofIQVisitorforthemanagement

ofvisitorIDsinconjunctionwithIQMA

•Distance-timecalculationsincombination

withIQMA

•Enhancedreportingandlogging-generation

of reports directly from WINMAG plus,

unlimited report period by back-up

functionality as well as export and import of

reports

•Compatiblewith64bitoperatingsystems:

-WindowsServer2008(Foundation-Version

not available)

-WindowsServer2008R2

-Windows8/8.1(withoutRT)

-WindowsServer2012R2(Foundation-

Version not available)

-Windows10

•NotificationmodulewiththeSMS,E-Mail,

Voice Mail and Fax support

•ESPA4.4.4interfaceavailable

•Highsecurityfailoverfunctionalitybuiltin,

with multiple redundancy

- 2nd PC with identical data in the network

- 2 transmission paths

- hot-standby redundancy

•Connectionpossibilitiesviaopeninterfaces

-OPC-Server/Client

-BACnet-Server/Client

- WINMAG SDK

•ConnectionviaEthernet(TCP/IP)e.g.VdSIP

network

•ConnectiontoEIBandModbuspossible

Note: To use specific features, necessary options needs to be ordered

WINMAG PLUS V6.2 ADDITIONAL FEATURES

Page 6: WINMAG PLUS V6 - Honeywell · • Access Control • Video Surveillance • Building Automation • Escape Route • PAVA • Building Management Systems (OPC or BACnet interfaces)

INTEGRATED SYSTEMS OFFER MANY SYNERGIES:

Youneedlessmaterial,reducedinstallation

time and they are easier to maintain.

Therefore, they are standard in modern

building technology.

Each system speaks its own language, has

its own requirements and requires certain

knowledge of the user.

The all-encompassing, superior alarm

management system WINMAG plus

understands and translates the information

from all different types of systems.

It combines information under a common user

interface and messages from the following

systems:

•FireandIntrusion

•AccessControl

•VideoSurveillance

•BuildingAutomation

•EscapeRoute

•PAVA

•BuildingManagementSystems

(OPC or BACnet interfaces)

This and the ability to operate the entire system

from a single workstation reduces the overall

cost of the system. Immediate and targeted

workflows complete this picture.

WINMAG PLUS V6.2 CONNECTION OF DIFFERENT SYSTEMS IN THE BUILDING AND ALARM MANAGEMENT

Access Control• Pro-Watch • WIN-PAK

• IQ MultiAccess • Third-Party

Intrusion• MB-Secure • MB-classic

• Galaxy • Third-Party

Graphical User Interface 2D Floor Plans • 3D Models • AutoCAD

Video • MAXPRO VMS • Fusion • HRDP • Third-Party

Escape Route• Assa Abloy • Dorma

Open Standards• OPC Client and Server • BACnet Client and Server • SDK

Workflow Management• Customizable Script Language • Adapts to Customer Processes

Notification• SMS

• Email • Voicemail

• Fax

PAVA • VARIODYN D1

Fire• Notifier (US + UK)

• Esser • Gent

• Third-Party

WINMAG® Plus Ecosystem

Page 7: WINMAG PLUS V6 - Honeywell · • Access Control • Video Surveillance • Building Automation • Escape Route • PAVA • Building Management Systems (OPC or BACnet interfaces)

WINMAG PLUS V6.2 CONNECTION OF DIFFERENT SYSTEMS IN THE BUILDING AND ALARM MANAGEMENT

Access Control• Pro-Watch • WIN-PAK

• IQ MultiAccess • Third-Party

Intrusion• MB-Secure • MB-classic

• Galaxy • Third-Party

Graphical User Interface 2D Floor Plans • 3D Models • AutoCAD

Video • MAXPRO VMS • Fusion • HRDP • Third-Party

Escape Route• Assa Abloy • Dorma

Open Standards• OPC Client and Server • BACnet Client and Server • SDK

Workflow Management• Customizable Script Language • Adapts to Customer Processes

Notification• SMS

• Email • Voicemail

• Fax

PAVA • VARIODYN D1

Fire• Notifier (US + UK)

• Esser • Gent

• Third-Party

WINMAG® Plus Ecosystem

Page 8: WINMAG PLUS V6 - Honeywell · • Access Control • Video Surveillance • Building Automation • Escape Route • PAVA • Building Management Systems (OPC or BACnet interfaces)

Subject to change without notice.

HIS-WINMAG_plus_62-01-ME(0420)DS-ZB©2020HoneywellInternationalInc.

EXPANSION LICENSES WM3010 IntrusionMBseriesWM3020 IntrusionGalaxyWM3110 Firesystem-EsserWM3120 Firesystem-GentWM3130 Firesystem-NotifierWM3140 VARIODYND1WM3200 AccessControlIQMultiAccessWM3201 AccessControlPro-WatchWM3202 AccessControlWIN-PAKWM3210 HoneywellVideoWM3220 DS6750/DS7700WM3230 NursecallWM3240 DTSSystemWM3250 EscapeRouteWM3260 CMSIWM3510 GeutebrückVideoWM3520 DallmeierVideoWM3530 SeeTecVideoWM3540 MilestoneVideoWM3550 LegacyVideosystems

WM4010 RedundancyWM4030 MultiMonitorWM4040Auto-CAD®WM4130 EscalationWM4160 Loginreader

OPC AND BACNET WM5100OPCServerWM5200 WINMAGplusOPCClientWM5300 OPC/BACnet500TagsWM5600WINMAGplusBACnetServerWM5700 WINMAGplusBACnetClient WM5800SoftwareuniversalgatewayforPCWM6001WINMAGplusSDK

SERVICE784830 Entryofareportingpoint784832.10Enteringatextpage784833 Inputofagraphicspage784839 Conversionofagraphicspage

OPTIONS

WINMAG PLUS WM1001 WINMAGplusinstallationmedium

BASE LICENSES WINMAG PLUS WM2010 Basepackagewith500datapointsWM2020 Basepackagewith1.500datapointsWM2030 Basepackagewith2.500datapointsWM2040 Basepackagewith10.000datapointsWM2050 Basepackagewith20.000datapointsWM2060 Basepackagewith50.000datapoints

UPGRADE PACKAGE WINMAG PLUS TO NEWEST VERSION WM2310 Upgradeincluding2.500datapointsWM2320 Upgradeincluding10.000datapointsWM2330 Upgradeincluding20.000datapointsWM2340 Upgradeincluding50.000datapoints

DATA POINT EXTENTIONS FOR BASE PACKAGE WM2110 Additional500datapointsWM2120 Additional2.500datapointsWM2130 Additional5.000datapointsWM2140 Additional10.000datapoints

CLIENT LICENSESWM2200 WINMAGplusclient - single licenseWM2210 WINMAGplusclient -licensepackage,5pcs.WM2220 WINMAGplusclient -licensepackage,10pcs.WM2230 WINMAGplusclient -licensepackage,25pcs.

WINMAG PLUS V6.2 ORDERING INFORMATION

For More Informationwww.security.honeywell.com/me

Honeywell Commercial SecurityEmaar Business Park,

SheikhZayedRoad

Building No. 2, 2ndFloor,201

Post Office Box 232362

Dubai, United Arab Emirates

Tel:+97144541704