windows storage server 2012 on lenovo...

38
Windows Storage Server 2012 on Lenovo ThinkServer Lenovo Enterprise Product Group Version 1.0 May 2013 © Copyright Lenovo 2013

Upload: others

Post on 03-Oct-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

Lenovo Enterprise Product Group

Version 1.0

May 2013

© Copyright Lenovo 2013

Page 2: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

2

LENOVO PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER

EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-

INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. This information

could include technical inaccuracies or typographical errors. Changes may be made to the

information herein; these changes will be incorporated in new editions of the publication.

Lenovo may make improvements and/or changes in the product(s) and/or the program(s)

described in this publication at any time without notice.

Any performance data contained herein was determined in a controlled environment; therefore,

the results obtained in other operating environments may vary significantly. Some

measurements may have been made on development-level systems, and there is no guarantee

that these measurements will be the same on generally available systems. Furthermore, some

measurements may have been estimated through extrapolation. Actual results may vary. Users

of this document should verify the applicable data for their specific environment.

The following terms are trademarks of Lenovo in the United States, other countries, or both: Lenovo, ThinkServer.

Intel and Xeon are trademarks of Intel Corporation in the U.S. and/or other countries.

Microsoft, Windows Storage Server 2012, Windows Server 2012, and the Windows Logo are trademarks of Microsoft Corporation in the United States and/or other countries.

Page 3: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

3

Contents

1.0 Introduction ................................................................................................................... 5

2.0 Windows Storage Server Solutions ............................................................................... 6

3.0 Server Hardware Recommendations ............................................................................ 7

4.0 Understanding Storage Structure in WSS 2012 ........................................................... 10

5.0 Configuration Guide .................................................................................................... 13

5.1 Pre-installation tasks ............................................................................................... 13

5.2 Configure the RAID Subsystem ................................................................................ 13

5.3 Network Considerations .......................................................................................... 18

5.4 OS Installation and Initial Configuration ................................................................. 19

5.5 Access Controls ........................................................................................................ 21

6.0 Configuring WSS Features ........................................................................................... 21

6.1 Creating Volumes .................................................................................................... 21

6.2 Configuring Storage Services ................................................................................... 24

6.3 Configuring Data Management Services ................................................................. 27

7.0 Management ............................................................................................................... 35

7.1 Windows Server Management ................................................................................ 35

7.2 File Server Resource Manager ................................................................................. 35

8.0 Deployment ................................................................................................................. 36

8.1 Network Connections .............................................................................................. 36

9.0 References ................................................................................................................... 37

Page 4: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

4

List of Figures

Figure 1 – Stand-alone Storage Server ............................................................................................ 6

Figure 2 – RD330 with 4x 3½” HDD Bays ......................................................................................... 8

Figure 3 – RD430 with 8x 3½” HDD Bays ......................................................................................... 9

Figure 4 – RD430 with 12x 3½” HDD Bays ..................................................................................... 10

Figure 5 – WSS Storage Taxonomy ................................................................................................ 11

Figure 6 – Windows Disk Management ......................................................................................... 12

Figure 7 – File and Storage Services Management ....................................................................... 13

Figure 8 – Entry Server Recommended Drive Configuration ........................................................ 16

Figure 9 – Large Capacity Server Recommended Drive Configuration ......................................... 17

Figure 10 – Performance Server Recommended Drive Configuration .......................................... 18

Figure 11 – Server Manager .......................................................................................................... 20

Figure 12 – Disk Manager Create Volume Wizard ........................................................................ 22

Figure 13 – Steps to Creating Volumes from Storage Spaces ....................................................... 22

Figure 14 – Create a Storage Pool from Physical Disks ................................................................. 23

Figure 15 – Create a Virtual Disk from a Storage Pool .................................................................. 23

Figure 16 – SMB Share - Quick Profile Share Settings ................................................................... 25

Figure 17 – iSCSI Manager ............................................................................................................. 27

Figure 18 – BranchCache Deployment .......................................................................................... 28

Figure 19 – Deduplication Settings Wizard ................................................................................... 30

Figure 20 – DFS Management ....................................................................................................... 31

Figure 21 – Add Folder to a DFS Namespace ................................................................................ 32

Figure 22 – Volume Shadow Copies Configuration ....................................................................... 33

Figure 23 – RD430 Network Connections ..................................................................................... 37

List of Tables

Table 1 – Entry Server Configuration .............................................................................................. 8

Table 2 – High Capacity Server Configuration ................................................................................. 9

Table 3 – Performance Server Configuration .................................................................................. 9

Table 4 – Expansion Options ......................................................................................................... 10

Table 5 – RAID Properties .............................................................................................................. 14

Page 5: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

5

1.0 Introduction

Microsoft Windows Storage Server 2012 (WSS 2012) offers organizations of all sizes new storage

solutions that rival the functionality and scalability of advanced storage area networks, while

reducing management costs and complexity.

With WSS 2012, organizations can confidently deploy business-critical applications on a storage

solution delivering enterprise-class storage features, availability, reliability, and performance at

a fraction of the cost of traditional storage solutions.

WSS 2012 provides a unified storage solution that simultaneously supports file-based (SMB,

NFS), as well as block-based (iSCSI SAN) storage protocols. In addition, WSS 2012 provides

features typically associated with high-end, expensive Fibre Channel SANs, such as thin

provisioning, network multipath I/O, data deduplication, continuous availability, and live

migration.

WSS 2012 is built on Windows Server 2012 core technologies and is optimized for file serving,

but keeps essential infrastructure services available, such as Active Directory, DHCP, DNS,

Internet Information Services (IIS), Hyper-V (for up to two VM’s), and Print and Document

services.

WSS 2012 supports full Active Directory integration, so policies and access controls are set the

same as with direct attached storage on a Windows Server system.

WSS 2012 uses the same management tools as those that come with the other Windows Server

editions (Server Manager and PowerShell), and tools like Microsoft System Center can further

automate management functions. WSS 2012 can provide a single management interface for all

storage, simplifying monitoring and diagnosis when multiple storage solutions are deployed.

Lenovo offers validated WSS 2012 Standard storage solutions deployed on Lenovo ThinkServers

via the Reseller Option Kit (ROK) program. These solutions can be tailored to customers’ specific

needs through Lenovo Business Partners. Lenovo servers, plus WSS 2012, create data storage

solutions that deliver the performance, reliability, and value of the Lenovo servers with the

advanced storage features, seamless integration into IT environments, and familiar Windows

management of Windows Server 2012.

This document describes WSS 2012 solutions for departments, workgroups and mid-size

enterprises on Lenovo ThinkServer servers, and provides guidance for installing, configuring, and

supporting a Lenovo WSS 2012 storage server solution. The audience for this document is IT

administrators and managers, as well as business partners planning to evaluate or deploy these

storage solutions using Lenovo servers. This document assumes a working knowledge of

Windows networking and server software. Additional information beyond the scope of this

document can be found in the references.

Page 6: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

6

2.0 Windows Storage Server Solutions

Windows Storage Server 2012 solutions are well suited to Small Business and Branch Office

deployments, as well as mid-market and departmental applications. WSS 2012 storage servers

support enterprise workloads, including database, virtualization, and data storage applications.

In its simplest form, Widows Storage Server can be deployed as a standalone network attached

storage device, providing unified file storage hosting SMB and NFS file shares, SMB file shares

for server applications (SQL over SMB, Hyper-V over SMB), and iSCSI targets for applications

requiring block I/O (see Figure 1). WSS 2012 is licensed for unlimited clients without requiring

Client Access Licenses (CALs).

Access to the storage is provided over cost-efficient Ethernet (1 GbE or 10 GbE).

The solution easily supports Microsoft or third party anti-virus applications.

Figure 1 – Stand-alone Storage Server

Other important roles and features of WSS 2012 that can be employed include:

Data Deduplication – Deduplication can significantly improve the efficiency of storage

space utilization by storing a single copy of identical data on the volume. This can

deliver storage optimization ratios of 2:1 for general file servers and up to 20:1 for

virtualization data.

DFS Namespaces and Replication – In a larger network, users can be given a centralized

folder namespace, through which the underlying file shares on different servers and in

different sites are made available to access and store files. DFS Namespaces map

clients’ logical file requests to physical server files without having to search or map

Page 7: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

7

multiple locations. If deployed in a distributed environment (i.e. a branch office), DFS

Replication provides synchronization capabilities between the central and remote

servers across limited bandwidth network connections.

BranchCache – BranchCache optimizes the usage of WAN links by caching the remote

data locally based on predefined policies. When a user accesses content on remote

servers, BranchCache copies content from the remote servers and caches the content

on the branch office server, allowing compatible clients to access the content from the

local server rather than over the WAN. Subsequent requests for the same data will be

served from the local server until updates are required.

Volume Shadow Copy Services (VSS) is used to create a point-in-time image (shadow

copy) of one or more volumes. It provides enhanced data protection through high

fidelity backups, rapid data restores, and data transport. Volume Shadow Copy Service

(VSS) for SMB file shares allows performing of backup operations using the snapshots of

remote file shares supporting SMB-based server applications (for example, SQL over

SMB).

Other important roles and features of WSS 2012 that can be employed to improve performance

and resiliency include:

• SMB Multichannel enables aggregation of multiple redundant network paths between

application server SMB 3.0 clients and SMB 3.0 file shares hosted on the storage server.

This enables server applications to take full advantage of all available network

bandwidth and be resilient to a network failure.

• NIC Teaming (also known as load balancing and failover – LBFO) allows multiple network

adapters to be combined to provide a single fault tolerant or load balanced connection

for better performance and availability.

3.0 Server Hardware Recommendations

This section provides an overview of the recommended ThinkServer configurations required to

implement Windows Storage Server solutions. This information can be used to plan and procure

the required components to set up the solution.

Table 1, Table 2, and Table 3 provide recommended server configurations as a basis for

solutions planning. The server hardware can be configured to optimize for cost and

performance requirements. Disk and connectivity options (see Table 4, page10) enable the

storage server to leverage existing networks or address capacity and performance requirements.

Modification of the configurations to meet specific needs can be accomplished by adjusting the

server configurations or by adding more servers as needed. The factors most likely to be

modified to scale the solution include:

Page 8: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

8

Increase processing bandwidth for auxiliary processes (e.g. anti-virus, deduplication,

backup) by raising the performance and power rating of the processors, and increasing

the amount of installed memory in each WSS 2012 server.

Increase network IOPs by increasing the number of NIC ports, or the bandwidth of the

ports in each WSS 2012 server.

Expand the storage array capacity by adding more, or higher capacity drives.

Enhance performance by adding additional drives (more spindles in a RAID virtual drive),

or by moving from SATA to high RPM SAS drives.

Isolate the OS and data into separate drive groups to increase RAID migration options

and protect data in the event of a drive failure, or organize all physical drives into a

single drive group divided into two virtual drives to optimize the available storage

capacity.

Entry Server Configuration – provides an affordable, entry-level Windows Storage Server

solution. Using optional SATA HDDs, the storage server provides up to a maximum of 12 TB (4x

3TB SATA HDDs) storage capacity.

Table 1 – Entry Server Configuration

Part Number Description Quantity

4304-E1x RD330 (1U Rack with 4x 3½” Hot Swap HDD Bays) - 1x Intel Xeon Processor E5-2407 (4C, 10M Cache, 2.20 GHz,

6.40 GT/s QPI) - 1x 4 GB DDR3-1333MHz (1Rx4) RDIMM - Intel Embedded I-350 Dual Port GbE - Intel 82574 GbE (dedicated or shared with TMM) - ThinkServer Management Module - DVD-RW - 1x 550W Redundant Power Supply - ThinkServer Tool-less Rail Kit

1

0A89463 ThinkServer RAID 700 Adapter (RAID 0, 1, 5, 6, 10, 50, 60) 1 67Y2647 ThinkServer RAID 700 Battery 1 0A89475 2TB 7200 RPM, 6Gb/s 3½” Hot Swap Enterprise SATA HDD 4 67Y2624 ThinkServer Management Module Premium for Remote iKVM 1 0A89427 550W Redundant Power Supply 1 0C19614 Windows Storage Server 2012 Standard (2 CPU) – ROK 1

Figure 2 – RD330 with 4x 3½” HDD Bays

High Capacity Server Configuration – provides up to a maximum of 24 TB storage capacity using

optional SATA HDDs (8x 3TB SATA HDDs), with performance suitable for most file serving

applications.

Page 9: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

9

Table 2 – High Capacity Server Configuration

Part Number Description Quantity

3064-G4x RD430 (2U Rack with 8x 3½” Hot Swap HDD Bays) - 1 x Intel Xeon Processor E5-2420 (6C, 15M Cache, 1.90 GHz,

7.20 GT/s QPI) - 1x 8 GB DDR3-1333MHz (2Rx4) RDIMM - Intel Embedded I-350 Dual Port GbE - Intel 82574 GbE (dedicated or shared with TMM) - ThinkServer Management Module - DVD-RW - 1 x 800W Redundant Power Supply - ThinkServer Tool-less Rail Kit

1

0A89463 ThinkServer RAID 700 Adapter (RAID 0, 1, 5, 6, 10, 50, 60) 1 67Y2647 ThinkServer RAID 700 Battery 1 0A89475 2TB 7200 RPM, 6Gb/s 3½” Hot Swap Enterprise SATA HDD 8 67Y2624 ThinkServer Management Module Premium for Remote iKVM 1 0A89426 800W Redundant Power Supply 1 0A89423 Lenovo Gigabit ET Dual Port Server Adapter by Intel (Dual Port,

1000BASE-T) 1

0C19614 Windows Storage Server 2012 Standard (2 CPU) – ROK 1

Figure 3 – RD430 with 8x 3½” HDD Bays

Performance Server Configuration – optimized for storage array performance, this configuration

provides up to a maximum of 7.2 TB utilizing high-speed SAS HDDs (12x 600GB SAS HDDs). Dual

CPUs and expanded memory provide additional processing capability, and enable many other

functions such as data deduplication and antivirus to execute in the background without

affecting performance of the file server.

Table 3 – Performance Server Configuration

Part Number Description Quantity

3057-E5x RD430 (2U Rack with 8x 3½” Hot Swap HDD Bays) - 2 x Intel Xeon Processor E5-2420 (6C, 15M Cache, 1.90 GHz,

7.20 GT/s QPI) - 2x 16 GB DDR3-1333MHz (2Rx4) RDIMM - Intel Embedded I-350 Dual Port GbE - Intel 82574 GbE (dedicated or shared with TMM) - ThinkServer RAID 700 Adapter w/ Battery (RAID 0, 1, 5, 6, 10,

50, 60) - ThinkServer Management Module Premium for Remote iKVM - 2 x 800W Redundant Power Supply - ThinkServer Tool-less Rail Kit - Internal Optical Not Supported

1

67Y2618 600 GB 15K RPM, 6Gb/s 3½” Hot Swap SAS HDD 12

Page 10: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

10

Part Number Description Quantity

0C19497 Lenovo 10Gbps Ethernet X540-T2 Server Adapter by Intel (Dual Port, 10GBASE-T)

1

0C19614 Windows Storage Server 2012 Standard (2 CPU) – ROK 1

Figure 4 – RD430 with 12x 3½” HDD Bays

Table 4 provides recommended options to increase memory and storage capacity, and enable

connectivity to various Ethernet networks.

Table 4 – Expansion Options

Option Description Part Number

Memory 4 GB DDR3-1333MHz (1Rx4) RDIMM 0A89411 8 GB DDR3-1333MHz (2Rx4) RDIMM 0A89412 16 GB DDR3-1333MHz (2Rx4) RDIMM 0A89413

HDDs 2 TB 7200 RPM 3.5 HS SATA 0A89475 3 TB 7200 RPM 3.5 HS SATA 0A9477 600 GB 15000 RPM 3.5 HS SAS 67Y2618

Network Adapters

Lenovo 10Gbps Ethernet X520-DA2 Server Adapter by Intel (Dual Port, 10GSFP+Cu)

0C19486

Lenovo 10Gbps Ethernet X520-SR2 Server Adapter by Intel (Dual Port, 10GBASE-SR)

0C19487

Lenovo 10Gbps Ethernet X540-T2 Server Adapter by Intel (Dual Port, 10GBASE-T)

0C19497

Lenovo Ethernet I340 Quad Port Server Adapter by Intel (Quad Port, 1000BASE-T)

0A89424

Lenovo Gigabit ET Dual Port Server Adapter by Intel (Dual Port, 1000BASE-T)

0A89423

Lenovo 10Gbps Ethernet Fiber Module by Intel (for use with X520-DA2, 10GBASE-SR)

0C19488

4.0 Understanding Storage Structure in WSS 2012

Optimally configuring storage requires some knowledge of how it will be used. In addition to

determining the desired priorities of performance, fault tolerance, and storage capacity,

examine how storage capacity will be expanded when necessary, how access management and

permissions for various shares will be controlled, and the purpose of the data.

In WSS 2012, storage is defined by levels of abstraction and capabilities that start from physical

storage devices (HDDs), and span to file shares on a network (see Figure 5).

Page 11: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

11

Figure 5 – WSS Storage Taxonomy

At the lowest level, the RAID controller creates drive groups from a collection of physical disks.

Virtual drives are created from a drive group, and have properties such as capacity and RAID

configuration. Virtual drives appear to Windows as a disk.

The Disk Management snap-in in Computer Management (see Figure 6) is the accustomed way

to create and manage data storage partitions in Windows operating systems. Disk partitions are

a way of dividing physical disk space so that each section functions as a separate unit. Partitions

are created from disks and are of either type MBR or GPT. From partitions, volumes are created

that have a file system (NTFS, FAT, FAT32, or ReFS), an allocation unit size, and can be associated

with a drive letter.

Page 12: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

12

Figure 6 – Windows Disk Management

WSS 2012 adds a new storage capability called Storage Spaces, which virtualizes collections of

physical disks into Storage Pools. A Storage Space is created from a storage pool, and is

represented as a virtual disk in Windows, essentially replacing hardware RAID provided by the

RAID controller. A Storage Space has attributes such as desired level of resiliency, provisioned

capacity, and performance level.

Storage Spaces have the following limitations:

• Not supported on boot, or system volumes

• Drives must be 10GB or larger

• When including a physical drive into a storage pool, the contents of the drive being

added will be lost

• Only un-formatted/un-partitioned drives can be added to a storage pool

• A simple storage pool must consist of at least one drive

• A mirrored pool must have at least two drives

• A pool with parity must have at least three drives

• All drives in a pool must use the same sector size

Storage Spaces are managed from the File and Storage Services tab in the Server Manager (see

Figure 7).

Page 13: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

13

Figure 7 – File and Storage Services Management

5.0 Configuration Guide

5.1 Pre-installation tasks To prepare for installation of WSS 2012, ensure the following tasks are completed:

1. Select and install the desired server storage and connectivity options. Recommended

options are listed in Table 4, page 10).

2. Ensure that the server firmware is up-to-date. If necessary, update the system BIOS,

ThinkServer Management Module (TMM), and RAID controller to the latest version.

These updates can be installed using the ThinkServer Firmware Updater tool, available

at http://www.lenovo.com/support.

3. Configure BIOS settings including:

1. System date and time

2. Boot devices and boot order

3. TMM Management interfaces

5.2 Configure the RAID Subsystem Lenovo does not currently support WSS 2012 installation using the EasyStartup configuration

tool to preconfigure the RAID subsystem and install the operating system. This method of

installation may be supported in a future release.

For this reason, the RAID configuration must be configured using either the pre-boot WebBIOS

Configuration Utility or the MegaRAID CLI interface, which is suitable for scripting. The

WebBIOS Configuration Utility allows the creation, management, and deletion of RAID arrays

Page 14: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

14

from the available physical drives attached to the RAID adapter. If RAID volumes have already

been configured, the Configuration Utility does not automatically change their configuration.

The RAID subsystem must be configured before attempting to install the operating system.

The first step to creating a RAID configuration is to configure the drives into a drive group, which

holds one or more divisions known as virtual drives. The virtual drive will be assigned a RAID

level, which is seen by the host computer system as a single drive volume.

The RAID level selected should be based on consideration of several factors, the most important

being performance, fault tolerance, and storage capacity. However, not all of these factors can

be optimized at the same time. Table 5 describes the characteristics of each available RAID

level, and factors to consider when selecting the RAID configuration.

If Storage Spaces will be used in WSS 2012, physical drives should not be configured into RAID

groups, but instead, should be left as drive groups of only one drive each configured as a RAID 0

virtual drive.

Table 5 – RAID Properties

RAID Level

Description #

Drives Capacity

1

Fault Tolerance

Performance Considerations

RAID 0

Block-level striping without parity or mirroring

1 or more

n*(HDD) None – all data in the array is lost

Read/write performance is generally improved, especially for sequential access, because adjacent data can be accessed from more than one hard drive simultaneously.

RAID 1 Mirroring without parity or striping

2 1*(HDD) 1 drive

Write performance is minimally impacted by the overhead associated with duplicating the data. Read performance is on par with RAID 0.

RAID 5

Block-level striping with distributed parity

3 or more

∑ (HDD1 to n-1) 1 drive

High throughput can be achieved, especially for small random reads. Read performance is almost as good as RAID 0 for the same number of disks. Random write performance suffers from overhead of updating parity for each write. Use of write back cache can reduce this performance impact.

RAID 6

Block-level striping with double distributed parity

4 or more

∑ (HDD1 to n-2) 2 drives

No performance penalty for read operations, but some performance penalty on write operations due to overhead associated with parity calculations.

1 n = number of HDDs in the drive group. HDD represents capacity of a single drive (Assume all HDDs are

the same size for purposes of this calculation).

Page 15: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

15

RAID Level

Description #

Drives Capacity

1

Fault Tolerance

Performance Considerations

RAID 10

Top Level RAID 0, Bottom Level RAID 1

4, 6, … n*(HDD)/2

1 drive from any

RAID 1 group

In most use cases, RAID 10 provides better throughput and latency than all other RAID levels except RAID 0, which wins in throughput. It is preferable for I/O-intensive applications such as database, email, and web servers, as well as for any other use requiring high disk performance.

RAID 50

Top Level RAID 0, Bottom Level RAID 5

6, 8, … ∑ (HDD1 to n-1)/2

1 drive from any

RAID 5 group

Improves upon the performance of RAID 5 particularly during writes. Recommended for applications that require high fault tolerance, high request rates, high data transfers, and medium-to-large capacity.

RAID 60

Top Level RAID 0, Bottom Level RAID 6

8, 10, … ∑ (HDD1 to n-2)/2

2 drives from any

RAID 6 group

Improves upon the performance of RAID 6. Despite the fact that RAID 60 is slightly slower than RAID 50 in terms of writes due to the added overhead of more parity calculations, best with data that requires high reliability, high request rates, high data transfers, and medium-to-large capacity.

The basic steps to create a RAID configuration are as follows:

1. Select a configuration method from the Configuration menu (New Configuration, or Add

Configuration).

2. Create drive groups using the available physical drives.

3. Define the virtual drive(s) using the space in the drive groups.

4. Initialize the new virtual drive(s).

To enter the WebBIOS RAID Configuration Utility, power on or reboot the system. At the

prompt, type CTRL-H to launch the LSI WebBIOS Configuration Utility.

Storage can be partitioned as follows for the recommended hardware configurations:

Entry Server

The entry server must maximize the available storage capacity.

As shown in Figure 8, all available physical drives are organized into a single drive group.

The drive group is organized into two virtual drives. The virtual drives are configured in

a RAID 5 geometry to optimize the storage capacity available, and protect against a

drive failure.

The first virtual drive (Disk0) will be used for the operating system and its associated

partitions, and should be given 100 GB.

The second virtual drive (Disk1) will be used for file server data, and will use the

remaining capacity of the drive group.

Page 16: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

16

Figure 8 – Entry Server Recommended Drive Configuration

Large Capacity Server

The large capacity server is optimized to maximum storage capacity for the file server.

As shown in Figure 9, all available physical drives are organized into a single drive group.

The drive group is organized into two virtual drives. The virtual drives are configured in

a RAID 6 geometry to optimize the storage capacity available, and to provide greater

protection against a drive failure.

The first virtual drive (Disk0) will be used for the operating system and its associated

partitions, and should be given 100 GB.

The second virtual drive (Disk1) will be used for file server data, and will use the

remaining capacity of the drive group. This larger virtual drive can be further subdivided

into partitions within Windows as desired.

Page 17: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

17

Figure 9 – Large Capacity Server Recommended Drive Configuration

Performance Server

The performance server optimizes for maximum IOPS rather than maximum storage capacity.

As shown in Figure 10, the available physical drives are organized into two drive groups,

one composed of 2 drives, the second with all remaining drives.

The first drive group will be used for the operating system and its associated partitions,

and is organized into a single virtual drive (Disk0) configured in a RAID 1 mirrored

geometry. This provides optimum performance as well as protection against a drive

failure in this group.

The second drive group will be used for file server data, and is organized into a single

virtual drive (Disk1) configured in a RAID 6 geometry to provide optimum performance

for a range of I/O profiles as well as enhanced protection against a drive failure in this

group. This larger virtual drive can be further subdivided into partitions within Windows

as desired.

Page 18: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

18

Figure 10 – Performance Server Recommended Drive Configuration

5.3 Network Considerations When designing a storage network infrastructure, best practices dictate that storage data traffic

be separated from other network communications. Management traffic should also be isolated

to a separate network. Separation in the network can be achieved with the use of VLANs, or

separate physical networks. A minimum of one physical NIC port is required to support storage

traffic from clients to the storage server.

Storage traffic can also benefit from the increased bandwidth from 10GbE, if available in the

infrastructure, with performance comparable to a Fibre Channel SAN operating at 8 Gb/s.

Jumbo Frames, if supported end to end across all hardware, can also be enabled in the NICs

handling storage traffic. Jumbo Frames can provide a significant boost in overall throughput,

and reduce CPU utilization for large file transfers.

iSCSI operation does not require, but can be enhanced by, the use of the standards-based

extensions to Ethernet called Data Center Bridging (DCB). DCB provides QoS and bandwidth

management capabilities that help enable the convergence of data and storage traffic onto a

single unified fabric.

To support a resilient storage and network design, there should be no single point of failure.

Page 19: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

19

Multipath I/O (MPIO) is a feature that can utilize more than one physical path from a client to

the storage server providing fault-tolerance, load balancing, and performance enhancements.

In the event that a component causes a path to fail, multipath logic uses an alternate path for

I/O so that applications can still access their data. When all paths are active, load balancing

algorithms are utilized to increase throughput.

Link Aggregation or NIC Teaming, is similar to MPIO in that it provides fault tolerance through

redundant connections in the event of a network component failure, and aggregates available

bandwidth on multiple NIC ports. NIC teaming is configured in the NIC device driver itself, or

separately using Computer Manager to configure NIC teams though the OS. However, Microsoft

does not support NIC teaming for networks used for iSCSI communications.

Since NIC teaming is not supported for iSCSI communications, Microsoft Multipath I/O is

recommended to provide redundancy and load balancing when multiple network connections

are available. Microsoft MPIO is a feature enabled and configured in Server Manager.

5.4 OS Installation and Initial Configuration EasyStartup support for Windows Storage Server 2012 is not available. To install WSS 2012

manually, complete the following steps:

1. Connect the server to a network as required. 2. Depending on your server, attach an external CD/DVD reader device. 3. Install the OS from the ROK media and follow the prompts, completing the installation

as directed by the installation routine.

After the OS is successfully installed, logon to the system using the local administrator password

created during the installation process. After logging in, the Server Manager is displayed (see

Figure 11). In Server Manager, select “Local Server” to perform basic system configuration:

1. Change the Computer Name

2. Add to Domain2 (optional) or Workgroup – reboot will be required

3. Configure networking including NIC Teaming (optional), and Server IP address if not

using DHCP

4. Configure System Date and Time / Time Zone

5. Enable and configure Remote Desktop

6. Enable Remote Management (remote management of this server from other servers) –

enabled by default

7. Configure and install Windows Updates

2 WSS 2012 cannot be an actual domain controller, only a member of a domain.

Page 20: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

20

Figure 11 – Server Manager

By default, WSS 2012 installs only the Storage Services role that provides the basic functionality

required to manage file servers and storage. Additional Roles and Features can be added using

the Add Roles and Features Wizard. Additional roles include:

Active Directory Lightweight Directory Services (AD LDS)

DHCP Server

DNS Server

File and iSCSI Services

o File Server

o Branch Cache for Network Files

o Data Deduplication

o DFS Namespaces

o DFS Replication

o File Server Resource Manager

o File Server VSS Agent Service

o iSCSI Target Server

o iSCSI Target Storage Provider (VDS and VSS hardware providers)

o Server for NFS

Hyper-V

Print and Document Services

Web Server (IIS)

Page 21: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

21

Additional features relevant to the storage server include:

BitLocker Drive Encryption

BranchCache

Data Center Bridging

Multipath I/O

Windows Server Backup

Configuration of the relevant roles and features will be discussed in the sections that follow.

5.5 Access Controls Access to file server shares is controlled with User Accounts and Access Rights. User accounts

and associated rights can be managed locally on the standalone server using local accounts, or

through Active Directory when the server is joined to a domain.

The use of a domain simplifies user management by sharing access information with all systems

in the domain; otherwise, user information must be manually defined on each server.

6.0 Configuring WSS Features

6.1 Creating Volumes The virtual drives created by the RAID controller are presented to the OS as physical disks (as

discussed in section 4.0, “Understanding Storage Structure in WSS 2012.” Volumes and Shares

can be created using either Disk Management or File and Storage Services.

Using Disk Management Snap-in in Computer Management

Disks presented in Disk Manager must first be brought online and initialized as either MBR or

GPT partition types. GPT partitioning is required if partitions greater than 2 TB in size are

required. Once the drive has been initialized, one or more volumes must be created specifying

the following properties for each (see Figure 12):

Size of the volume (partition size)

Drive letter

File system

Allocation Unit size

Volume Label

Page 22: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

22

Figure 12 – Disk Manager Create Volume Wizard

Using File and Storage Services

Volumes can also be created from disks presented in File and Storage Services of Server

Manager. Recall that Disks can be Virtual Drives from the RAID controller, or Virtual Disks

created from Storage Pools in Storage Spaces.

Figure 13 – Steps to Creating Volumes from Storage Spaces

The transformation of raw storage to volumes and shares using Storage Spaces is shown in

Figure 13). Create one or more Storage Pools from available disks contained in the Primordial

Pool. A wizard guides the process (see Figure 14). Drives are allocated to a pool to be used for

storage, or as a spare drive in the event of a drive failure in fault tolerant configurations.

Page 23: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

23

Figure 14 – Create a Storage Pool from Physical Disks

Storage Pools can be used to create one or more Virtual Disks or Storage Spaces, essentially the

equivalent of a hardware RAID array. A wizard again guides the process (see Figure 15). Assign

appropriate properties to each Storage Space including:

Size of the Storage Space / Virtual Disk

Data protection level (Simple – no protection, Mirrored, or Parity)

Provisioning Type (Thin or Fixed)

Figure 15 – Create a Virtual Disk from a Storage Pool

Page 24: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

24

Create volumes from the disks, or Storage Spaces Virtual Disks presented in File and Storage

Services. Completed volumes should have a file system and drive letter available to Windows

for normal file operations.

6.2 Configuring Storage Services File and Storage Services include technologies that enable set up and management of the file

servers. These basic services are installed by default, and enable the use of Server Manager or

PowerShell to manage the storage functionality of the server.

However, in order to share folders and enable users to access files on this server from the

network using any of the storage services (SMB, NFS, or iSCSI), the File Server role is required.

These services are discussed in the following sections.

6.2.1 Server Message Block (SMB) File Services

The Server Message Block (SMB) protocol is a network file sharing protocol that allows

applications on a computer to read and write to files, and to request services from server

programs in a computer network. Using the SMB protocol, an application can access files or

other resources at a remote server. Windows Server 2012 and WSS 2012 introduce the new

version 3.0 of the SMB protocol, which provides enhancements including the reduction of

application latencies experienced by branch office users when accessing data over wide area

networks (WAN), and protecting data from eavesdropping attacks.

SMB File Services provide network shares for Windows-based users, and server application

environments. In particular, Hyper-V over SMB, enables storage of virtual machine files

(configuration, Virtual hard disk (VHD) files, and snapshots), and SQL Server over SMB enables

placement of log and data files, into SMB 3.0 network shares.

To create SMB shares, ensure the File Server role is installed. Create SMB shares in Server

Manager. SMB shares have several profiles:

• SMB Share – Quick: This basic profile creates a simple SMB file share, suitable for

general file sharing, typically for Windows-based computers. Share settings (access

based enumeration, share caching, and encrypted data access), and access control

permissions can be configured.

Page 25: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

25

Figure 16 – SMB Share - Quick Profile Share Settings

• SMB Share – Advanced: This profile offers additional options to configure a SMB file

share that are enabled with the File Server Resource Manager role including:

o Set folder owners for access-denied assistance

o Configure default classification of data in the folder for management and access

policies

o Enable quotas

• SMB Share – Applications: This profile creates an SMB file share with settings

appropriate for Hyper-V, SQL databases, and other server applications. It is essentially

the same as the quick profile, but it does not allow enablement of access‐based

enumeration, or offline caching.

SMB Multichannel is a feature of SMB File Services that enables the aggregation of network

bandwidth and network fault tolerance if multiple paths are available between the SMB 3.0

client and the SMB 3.0 server. This enables server applications to take full advantage of all

available network bandwidth and be resilient to a network failure. No extra features need to be

installed, as the technology is enabled by default.

6.2.2 Network File System (NFS) File Services

Network File System (NFS) provides file sharing for heterogeneous environments that consist of

both Windows and non-Windows computers such as Linux- or Mac-based environments.

VMware vSphere virtual machine files can also be placed onto NFS network shares.

In WSS 2012, NFS includes the components Server for NFS, and Client for NFS. Server for NFS

enables a server running WSS 2012 to act as a file server for other non-Windows client

computers. Client for NFS enables a computer that is running WSS 2012 to access files that are

stored on a non-Windows NFS server.

Page 26: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

26

To create NFS shares, ensure the Server for NFS role is installed. Create NFS shares in Server

Manager. NFS shares have several profiles:

• NFS Share – Quick: This basic profile creates a simple NFS share, suitable for general file

sharing, typically for UNIX-based computers. Share settings such as authentication

method, share permissions to configure access for UNIX hosts, and access controls to

optionally set NTFS permissions can be configured.

• NFS Share – Advanced: This profile offers additional options to configure a SMB file

share that are enabled with the File Server Resource Manager role including:

o Set folder owners for access-denied assistance

o Configure default classification of data in the folder for management and access

policies

o Enable quotas

6.2.3 iSCSI Block I/O Software Target

iSCSI Software Target enables a low-cost block-level shared storage alternative to SAN products.

The iSCSI Target Server also supports network or diskless booting, enabling multiple computers

to boot over the network from a single operating system image that is stored on the file server.

Before configuring iSCSI storage targets, refer to section 5.3, “Network Considerations.” If

redundant network paths are desired for high availability, Multipath I/O (MPIO) is required with

the use of multiple dedicated NIC ports on the server. NIC teaming is not supported when using

iSCSI.

To create an iSCSI target, ensure the iSCSI Target Server role is installed. Knowledge of the iSCSI

Initiators who will have access to the target is also required.

Create an iSCSi Target from the iSCSI Manager within File and Storage Services in Server

Manager (see Figure 17).

Page 27: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

27

Figure 17 – iSCSI Manager

The wizard will prompt for the properties of the iSCSI target, including:

• Location of the iSCSI target (targets are created as a folder residing on a Windows

Volume)

• Name and size of the iSCSI target

• iSCSI initiators which can access the virtual disk

• CHAP authentication to secure iSCSI connections (optional)

6.3 Configuring Data Management Services Data management services provide several capabilities to optimize the performance of the

storage system for remote users, support data protection and recovery, and simplify the

management of data across a large number of storage systems. These services are discussed in

the following sections.

6.3.1 BranchCache

BranchCache is a wide area network (WAN) bandwidth optimization technology. To optimize

WAN bandwidth when users access content on remote servers, BranchCache copies content

from main office or hosted cloud content servers, and caches the content at branch office

locations, allowing client computers at the branch offices to access the content locally rather

than over the WAN.

Page 28: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

28

At the branch offices, content requested by a client is stored on servers configured to host the

cache. Subsequent requests for the same content are served locally rather than downloading

the content from the content server over the WAN link. This reduces network bandwidth usage

and provides faster access to the files.

The topology for a BranchCache deployment is shown in (see Figure 18).

The source content in the main office is stored on BranchCache-enabled file servers, and has the

File Services server role and the BranchCache for Network Files role service installed. These file

servers use Server Message Block (SMB) to exchange information between computers.

The content cache at a branch office is hosted on one or more servers, which are called hosted

cache servers, and each has the BranchCache feature installed with Hosted Cache Mode

enabled.

Figure 18 – BranchCache Deployment

Deploy BranchCache for Network Files role:

To deploy BranchCache enabled content servers that are running the File Services server role,

install the BranchCache for Network Files role of the File Services server role.

After the file server has been installed, enable Hash Publication for BranchCache for shared

folders by using Group Policy or Local Computer Policy to enable BranchCache. In addition,

enable BranchCache on file shares according to your requirements. During the configuration of

the file server, specify whether BranchCache should publish the content for all, or a subset of

file shares.

Page 29: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

29

Deploy BranchCache feature – Hosted Cache Mode:

To install a BranchCache enabled, hosted cache server, enable the BranchCache feature.

After configuring the file server, configure the BranchCache Group Policy objects, enabling

BranchCache, and specifying the BranchCache mode (Hosted mode). Also, specify the server

from which to download data, the transfer latency threshold that triggers data to be cached,

and the amount of disk space to allocate to the cache.

6.3.2 Data Deduplication

Use Data Deduplication to reduce the number of duplicate blocks of data in storage. Data

Deduplication is much more effective in reducing the amount of data actually stored than Single

Instance Storage (SIS), or NTFS file system compression used in previous releases of Windows.

General-purpose file servers can typically reduce storage capacity utilization by a 2:1 ratio.

Virtualization data (such as VHD files) can often be optimized to reduce storage capacity

requirements by a 20:1 ratio.

When combined with BranchCache, the same optimization techniques are applied to data that is

transferred over the WAN to a branch office. Faster file download times and reduced

bandwidth consumption can result.

With Deduplication installed, the Deduplication Evaluation Tool (DDPEval.exe) can be run to

determine the expected savings if deduplication were enabled on a particular volume.

DDPEval.exe supports evaluation of local drives, as well as remote shares.

Deduplication was designed to support minimal hardware configurations, but as a general rule,

deduplication requires 1 CPU-core and 350 MB of free memory per volume, and can process

about 100 GB per hour (2 TB per day). Deduplication scales with additional CPU processor cores

and available memory to enable parallel processing of multiple volumes. The actual speed of

deduplication is dependent on CPU, disk I/O, memory, and available server resources at the

time deduplication runs. Deduplication is designed to pause if the server starts to run out of

resources to avoid impacting the server’s regular workload, so the busier the server is, the

longer the deduplication process will take. Deduplication can also be scheduled to further

reduce impact to the server.

Deduplication is not supported for files that are open and constantly changing for extended

periods of time, or that have high I/O requirements, for example, running virtual machines on a

Hyper-V host, live SQL Server databases, or active VDI sessions.

Deduplication will not process files that are constantly and exclusively open for write

operations. This means that there will be no deduplication savings unless the file is closed when

an optimization job attempts to process a file.

Page 30: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

30

Setting a hard quota on a volume root folder that has deduplication enabled is not supported.

However, a soft quota on a volume root that has deduplication enabled is supported.

Install the Data Deduplication role from the Add Roles and Features wizard. Configure

Deduplication for a particular Volume as shown in Figure 19.

Figure 19 – Deduplication Settings Wizard

6.3.3 Distributed File System (DFS) and DFS Replication

DFS Namespaces – DFS Namespaces enables the grouping of shared folders that are located on

different servers into one or more logically structured namespaces. Each namespace appears to

users as a single shared folder with a series of subfolders, even though the namespace can

consist of numerous file shares that are located on different servers and in multiple sites. Users

can navigate the namespace without needing to know the server names or shares hosting the

data.

DFS Replication – DFS Replication enables the efficient replication of folders (including those

referred to by a DFS namespace path) across multiple servers and sites. DFS Replication uses an

algorithm known as remote differential compression (RDC) to detect changes to data in a file,

enabling only the changed file blocks to be replicated instead of the entire file.

DFS Replication must be installed on all servers that will act as members of a DFS replication

group, and all servers in the replication group must be located in the same Active Directory

Page 31: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

31

forest. Replication can only occur on volumes formatted with the NTFS file system (ReFS, or the

FAT file system is not supported).

Install DFS Namespaces and Replication roles from File and Storage Services. Access DFS

Management from the Server Manager Dashboard tools (see Figure 20).

Figure 20 – DFS Management

Create DFS Namespaces – Before DFS Namespaces can be used, create one or more

Namespaces using the “New Namespace Wizard” found in DFS Management. When creating

the type of Namespace, keep in mind that DFS replication requires a domain-based namespace.

Once a namespace has been created, add shared folders to the namespace (Figure 21).

Page 32: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

32

Figure 21 – Add Folder to a DFS Namespace

Create DFS Replication Group – Replication groups are created using the DFS Manager. Identify

the folders to replicate, and create or identify target folders where replicated copies of shares

will be copied. The amount of bandwidth used by DFS replication can be configured. By default,

the wizard configures the replication group to synchronize continuously using all available

bandwidth. This can be restricted, or scheduled to specific days or times of day.

6.3.4 Volume Shadow Copy Service (VSS)

Shadow Copies of Shared Folders provides point-in-time copies (snapshots) of files and folders

that are located on shared resources. Snapshots are created at predetermined time intervals,

and allow users to view shared files and folders as they existed at points of time in the past,

however, shadow copies should not be considered as a replacement for regular backups.

Shadow copies can only be created on NTFS Volumes.

Volume Shadow Copy Services are built in to the operating system. Volume Shadow Copies are

configured from within the Shadow Copies tab of the disk’s volume Properties dialog box (see

Figure 22).

Page 33: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

33

Figure 22 – Volume Shadow Copies Configuration

6.3.5 VSS for SMB File Shares

WSS 2012 introduced a new feature called VSS for SMB File Shares, which extends VSS and

allows VSS-aware backup applications to create volume shadow copy snapshots of server

applications that store data on remote SMB 3.0 file shares, for example SQL over SMB.

Windows Server Backup in WSS 2012 does not support VSS for SMB File Shares.

To use VSS for SMB shares, the following requirements must be met:

• The application server and file server must be members of the same Active Directory

domain

• The File Server VSS Agent Service role service must be installed on the file server

• The File Share Shadow Copy agent must run in a security environment that has backup

operators or administrator privileges on both the application server and file server

• The File Share Shadow Copy agent, and the application must run in a security

environment that has no less than read-only permission on the file share data that will

be backed up

Install the File Server VSS Agent Service role from within the File and Storage Services roles.

Page 34: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

34

6.3.6 iSCSI Target Storage Provider (VDS and VSS Hardware Providers)

When the WSS 2012 server is being used as a SAN gateway to external iSCSI storage, the iSCSI

Target Storage Provider role services provide useful management capabilities.

The iSCSI Target Storage Provider role is available under the File and Storage Services role in

Server Manager. Two storage providers are included with the iSCSI Target Storage Provider role,

and are for remote Target management:

• Volume Shadow Copy Service (VSS) hardware provider

• Virtual Disk Service (VDS) hardware provider

Volume Shadow Copy Service (VSS) hardware provider – Similar to VSS for SMB Shares, the VSS

hardware provider enables applications on a server that are connected to an iSCSI target (an

iSCSI initiator), to perform volume shadow copies of data on the iSCSI virtual disk and which

supports restoration at the LUN level. The VSS hardware provider is installed on the iSCSI

initiator server that performs the backups, and the snapshots should be made from the iSCSI

initiator.

Virtual Disk Service (VDS) hardware provider – The VDS hardware provider is typically installed

on a storage management server, and enables older applications (such as Diskraid) that require

the Virtual Disk Service (VDS) hardware provider to manage iSCSI virtual disks (external to the

WSS 2012 server). VDS hardware providers are supplied by the manufacturers of hardware

RAID devices and are not included in WSS 2012.

6.3.7 Windows Offloaded Data Transfers

Offloaded Data Transfers (ODX) enables direct data transfers within or between compatible

storage devices without transferring the data through the host computer. By offloading the file

transfer to the storage array, ODX minimizes latencies, maximizes array throughput, and

reduces resource usage such as CPU and network consumption on the host computer.

The ODX environment must support the following:

• Only Windows 8 or Windows Server 2012 computers can initiate ODX data transfers

• File system filter drivers such as antivirus and encryption programs must support ODX

• ODX is not supported by the following file system filter drivers:

o Data Deduplication

o BitLocker Drive Encryption

• Files must be on an unencrypted basic partition

• Storage Spaces and dynamic volumes are not supported

• Files must be on an NTFS formatted volume. ReFS and FAT are not supported. Files can

be directly transferred to or from this volume, or from one of the following containers:

o A Virtual Hard Disk (VHD) that uses the VHD or VHDX formats

o A file share that uses the SMB protocol

Page 35: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

35

• The files must be 256 KB or larger – smaller files are transferred using a traditional (non-

ODX) file transfer.

• The application that performs the data transfer must be written to support ODX. The

following currently support ODX:

o Hyper-V management operations that transfer large amounts of data at a time,

such as creating a fixed size virtual hard disk (VHD), merging snapshot, or

converting virtual hard disks.

o File Explorer

o Copy commands in Windows PowerShell

o Copy commands in Windows command prompt (including Robocopy)

• Files should not be highly fragmented. Transfers of highly fragmented files will have

reduced performance.

ODX is enabled by default in WSS 2012, but there are considerations when deploying ODX in a

production environment. See Windows Offloaded Data Transfers Overview in Microsoft

TechNet for more information.

7.0 Management

7.1 Windows Server Management Server Manager in WSS 2012 allows the administrator to select and manage multiple remote

servers with the same interface that manages the local server. With the addition of the File and

Storage Services role in WSS 2012, Server Manager also includes functionality that allows

managing multiple remote file services, including managing file shares, iSCSI targets, storage

pools, and volumes. The Server Manager dashboard indicates any issues in the server

environment that might require attention.

In addition, Management in WSS 2012 leverages your existing Windows Server management

skills and tools including Active Directory, PowerShell, and System Center.

7.2 File Server Resource Manager File Server Resource Manager is a set of features that allow you to manage and classify data that

is stored on file servers. File Server Resource Manager is a role enabled in File and iSCSI

Services, and includes the following features:

• File Classification Infrastructure – File Classification Infrastructure automates data

classification processes to more effectively manage the data. You can classify files, and

apply policies based on the classifications. Example policies include dynamic access

control for restricting access to files, file encryption, and file expiration. Files can be

classified automatically by using file classification rules, or manually by modifying the

properties of a selected file or folder.

Page 36: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

36

• File Management Tasks – File Management Tasks enables the application of a

conditional policy or action to files based on their classification. The conditions of a file

management task include the file location, the classification properties, the date the file

was created, the last modified date of the file, or the last time the file was accessed.

The actions that a file management task can take include the ability to expire files,

encrypt files, or run a custom command.

• Quota Management – Quotas allow limiting the space that is allowed for a volume or

folder, and they can be automatically applied to new folders that are created on a

volume. Quota templates can also be defined that can be applied to new volumes or

folders.

• File Screening Management – File screens help control the types of files that a user can

store on a file server. Files that can be stored can be limited by their extension. For

example, you can create a file screen that does not allow files with an MP3 extension to

be stored on a file server.

• Storage Reports – Storage reports are used to help identify trends in disk usage and data

classification. You can also monitor a selected group of users for attempts to save

unauthorized files.

8.0 Deployment

8.1 Network Connections The server has three integrated 1 GbE ports (one can be shared with, or dedicated to the TMM

for system management), and the server can optionally support additional 1 GbE or 10 GbE

ports with optional Ethernet adapters.

The management port is typically connected to a separate Ethernet switch or VLAN dedicated to

management traffic (connection “A” in Figure 23).

In a basic configuration utilizing the onboard NICs, connections to the network can be made

with ports 1, and 2 (connection “B” in Figure 23).

When optional Ethernet adapters are used (connection “C” in Figure 23), additional aggregate

bandwidth, and multi-switch, fault tolerant network topologies are possible.

Page 37: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

37

Figure 23 – RD430 Network Connections

9.0 References

For information about hardware systems used in these solutions, see the following websites:

Hardware Maintenance Manual – ThinkServer RD430

http://download.lenovo.com/ibmdl/pub/pc/pccbbs/thinkservers/rd430hmm_en.pdf

Installation and User Guide - ThinkServer RD430

http://download.lenovo.com/ibmdl/pub/pc/pccbbs/thinkservers/rd430userguide_en.pdf

Hardware Maintenance Manual – ThinkServer RD330

http://download.lenovo.com/ibmdl/pub/pc/pccbbs/thinkservers/rd330hmm_en.pdf

Installation and User Guide - ThinkServer RD330

http://download.lenovo.com/ibmdl/pub/pc/pccbbs/thinkservers/rd330userguide_en.pdf

ThinkServer Management Module User Guide

http://download.lenovo.com/ibmdl/pub/pc/pccbbs/thinkservers/rd530rd630tmmug_en.pdf

Configuring ThinkServer RAID 500 and 700 Adapters

http://www.lenovo.com/images/products/server/pdfs/tech_resources/Configuring_LSI_Adapter

s.pdf

MegaRAID SAS Software User Guide

http://www.lsi.com/downloads/Public/MegaRAID%20Common%20Files/MegaRAID_SAS_SW_U

G_51530-00_RevJ.pdf

Page 38: Windows Storage Server 2012 on Lenovo ThinkServermedia.lenovo.ru/.../SERVERS_and_STORAGE/STORAGE/...2012_Soluti… · Windows Storage Server 2012 on Lenovo ThinkServer 5 1.0 Introduction

Windows Storage Server 2012 on Lenovo ThinkServer

38

For more information about WSS 2012 roles and features, see the following Microsoft websites:

Server Roles and Technologies in Windows Server 2012

http://technet.microsoft.com/en-us/library/hh831669.aspx

BranchCache Deployment Guide

http://technet.microsoft.com/en-us/library/jj572990.aspx

Windows Offloaded Data Transfers Overview

http://technet.microsoft.com/en-us/library/hh831628.aspx