DESCRIPTION
Wet Areas. Definitions BCA Part 3.8.1. Wet Area – an are within a building, supplied with water from a water supply Includes bathrooms, showers, laundries and sanitary compartments. Does Not Include Kitchens, bar area, kitchenettes or domestic food preparation areas - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/1.jpg)
Wet Areas
![Page 2: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/2.jpg)
Definitions BCA Part 3.8.1Wet Area – an are within a building, supplied with water from a water supply
Includes bathrooms, showers, laundries and sanitary compartments.Does Not Include Kitchens, bar area, kitchenettes or domestic food
preparation areas
Water Resistant – means the property of a system or material that restricts moisture movement and will not degrade under conditions of moisture.
Waterproof System – Combination of elements that are required to achieve a waterproof barrier, may include membrane, substrate, bond breakers, sealants etc
![Page 3: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/3.jpg)
Risk Potential For Wet AreasAS 3740
• High Risk – Shower Recesses
• Medium Risk – Rest of Bathroom & Laundry
• Low Risk – WC Room & immediate area around a kitchen sink, bar or similar
![Page 4: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/4.jpg)
AS 3740 – High Risk
• Means high probability of damage to structure if water within high risk area is not contained and discharged to drainage outlet.
![Page 5: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/5.jpg)
BCA Requirements High Risk Area
![Page 6: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/6.jpg)
BCA Requirements High Risk Area
![Page 7: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/7.jpg)
AS 3740 – Medium Risk
• Accidental spillage must be contained to with in the room.
• It is imperative that water not be allowed to pass into concealed spaces or to adjoining rooms
• Drainage not neccessary
![Page 8: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/8.jpg)
BCA Requirements Medium Risk Area
![Page 9: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/9.jpg)
BCA Requirements Medium Risk Area
![Page 10: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/10.jpg)
AS 3740 – Low Risk
• Risk of accidental spillage is low requirement to stop water traversing to adjoining rooms
![Page 11: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/11.jpg)
BCA Requirements Low Risk
![Page 12: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/12.jpg)
High Risk Area
![Page 13: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/13.jpg)
High Risk Area
![Page 14: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/14.jpg)
Preformed Shower Bases
![Page 15: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/15.jpg)
Preformed Shower Bases• Must be fully supported• Recessed Into Walls
![Page 16: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/16.jpg)
Preformed Shower Bases
![Page 17: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/17.jpg)
Bath Installation
![Page 18: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/18.jpg)
Bath Installation
![Page 19: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/19.jpg)
Definition
• Hob – Upstand at the perimeter to a shower area
![Page 20: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/20.jpg)
Hob Requirements BCA
![Page 21: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/21.jpg)
Hob Construction Detail (Internal)
![Page 22: Wet Areas](https://reader036.vdocuments.site/reader036/viewer/2022062517/56812e07550346895d936eda/html5/thumbnails/22.jpg)
Hob Construction Detail (External)