watchman trial

36
JOURNAL CLUB DR.NAGULA PRAVEEN I yr DM PG 2/8/2015 1

Upload: praveen-nagula

Post on 15-Jul-2015

169 views

Category:

Education


2 download

TRANSCRIPT

JOURNAL CLUB

DR.NAGULA PRAVEEN

I yr DM PG

2/8/2015 1

Contents

1.PREVAIL Trial

2.Valvular Heart Disease In India

3.ESH PRACTICE GUIDELINES for ABPM

4.BAT (BAROREFLEX ACTIVATION THERAPY)

5.IMAGE Challenge

6.ECG Challenge

7.Update on PCKS9 Inhibitors

8.SORT OUT III trial

2/8/2015 2

Prospective Randomized Evaluation Of The

WATCHMAN Left Atrial Appendage Closure

Device In Patients With Atrial Fibrillation

Versus Long Term Warfarin Therapy

The PREVAIL Trial

David R. Holmes JR, MD et alJACC,July 8,2014 2/8/2015 3

Background :

In the PROTECT AF (Watchman Left Atrial Appendage

Closure Technology For Embolic Protection In Patients With

Atrial Fibrillation) trial that evaluated patients with

nonvalvular atrial fibrillation (NVAF), left atrial appendage

(LAA) occlusion was noninferior to warfarin for stroke

prevention, but a periprocedural safety hazard was

identified.

2/8/2015 4

Objectives

The goal of this study was to assess the safety and efficacy of

LAA occlusion for stroke prevention in patients with NVAF

compared with long term warfarin therapy

2/8/2015 5

Seal Seal was defined as TEE documented residual peridevice flow < 5 mm in width

and no definite visible large thrombus on the device.2/8/2015 6

2/8/2015 7

2/8/2015 8

2/8/2015 9

Methods

Efficacy and safety of the device was assessed.

Patients with NVAF who had a CHADS2 (congestive heart failure,

hypertension, age > 75 years, diabetes mellitus, and previous stroke/

transient ischemic attack) score ≥ 2 or 1 and another risk factor were

eligible.

Patients were randomly assigned (in 2:1 ratio) to undergo LAA

occlusion and subsequent discontinuation of warfarin (intervention

group, n= 269) or receive chronic warfarin therapy (control group,

n=138).

Two efficacy and 1 safety coprimary endpoints were assessed.2/8/2015 10

Results

At 18 months , the rate of the first coprimary efficacy endpoint

(composite of stroke, systemic embolism [SE] and

cardiovascular/unexplained death) was 0.064 in the device group

versus 0.063 in the control group ( rate ration 1.07 [95% credible

interval (Crl): 0.57 to 1.89]) and did not achieve the prespecified

criteria noninferiority (upper boundary of 95% Crl ≥ 1.75).

The rate for the second coprimary efficacy endpoint (stroke or SE > 7 days’

postrandomization) was 0.0253 versus 0.0200 (risk difference 0.0053 [95%

Crl: - 0.0190 to 0.0273]), achieving noniferiority.

2/8/2015 11Credible interval (Bayesian method) is analagous to confidence interval in statistics

Early safety events occurred in 2.2% of the Watchman arm,

significantly lower than in PROTECT AF, satisfying the pre-

specified safety performance goal.

Using a broader, more inclusive definition of adverse effects,

these still were lower in PREVAIL trial than in PROTECT AF

(4.2% vs. 8.7%; p = 0.004).

Pericardial effusions requiring surgical repair decreased from

1.6% to 0.4% (p = 0.027), and those requiring

pericardiocentesis decreased from 2.9% to 1.5% (p = 0.36),

although the number of events was small.

2/8/2015 12

2/8/2015 13

Kaplan meier curve: Freedom from first primary endpoint(ITT)

2/8/2015 14

Freedom from second primary endpoint event 2/8/2015 15

2/8/2015 16

Demographic characteristics of patients receiving the watchman device

in PROTECT AF, CAP and PREVAIL

2/8/2015 17

2/8/2015 18

Stroke in AF is predominantly thromboembolic(sec to LAA

thrombus).

Warfarin was the therapy initially preferred, superior to aspirin.

Risk of bleeding,frequent monitoring,patients complaince are the

disadvantages.

NOACs – less frequent monitoring,improved compliance.

Bleeding ..????

2/8/2015 19

It is estimated that anticoagulation is not currently used in up

to 50% of eligible AF patients, which led to the development

of new oral anticoagulants (NOACs), whose efficacy have

been established in randomized clinical trials.

The rates of bleeding with approved doses of NOACs are

either similar to warfarin, or, in the case of apixaban -- lower,

but rivaroxaban,edoxaban and dabigatran had an increased

risk of gastrointestinal bleeding.

2/8/2015 20

Older patients,pts with renal dysfunction, the bleeding risks

assosciated with dabigatran were equal or greater than

warfarin.

Why stroke prevention in AF is still a challenge?

Bleeding risk,

absolute or relative C/I by the patient or physician,

long-term compliance,

cost,

lack of widely available antidotes.

2/8/2015 21

In patients with NVAF, the LAA is the location of the thrombus

felt to be the putative cause of stroke in approximately 90%

of cases.

In the pivotal PROTECT AF trial, comparing LAA occlusion

with warfarin, placement of the Watchman device was

noninferior for prevention of the primary composite endpoint of

ischemic or hemorrhagic stroke, cardiovascular or unexplained

death, and SE.

2/8/2015 22

PROTECT AF Clinical Trial Design

3000838-27

• Prospective, randomized study of WATCHMAN LAA Device vs long-term warfarin therapy

• 2:1 allocation ratio device to control

• 800 patients enrolled from Feb 2005 to Jun 2008

• Device group (463)

• Control group (244)

• Roll-in group (93)

• 59 enrolling centers (U.S. & Europe)

• Follow-up requirements

• TEE follow-up at 45 days, 6 months and 1 year

• Clinical follow-up biannually up to 5 years

• Regular INR monitoring while taking warfarin

• Enrollment continues in Continued Access Protocol (CAP Study)

Longer term follow-up of PROTECT AF has confirmed the

efficacy of LAA occlusion.

At a mean follow-up of 2.3 1.1 years, the primary efficacy

endpoint remained noninferior for device (3.0 vs. 4.3 [per 100

patient-years]; rate ratio 95% CrI: 0.44 to 1.30; probability of

noninferiority >0.999).

At 45 months of follow-up, LAA occlusion was superior to

warfarin for the primary composite efficacy endpoint.

At 45 months, the primary safety endpoint was noninferior for

the device group (increase in adverse events with warfarin),

2/8/2015 24

What went wrong with the trial ?

An early safety hazard was identified: an increase in

periprocedural events of pericardial effusions, which did

not result in mortality but did prolong hospital stay.

A risk for periprocedural stroke was also identified,

usually the result of air embolization during catheter

placement.

2/8/2015 25

Specific Safety Endpoint Events

• Pericardial effusions – largest fraction of safety events in device group

• Stroke events – most serious fraction of safety events in control group

• Bleeding events were also frequent

3000838-63

Safety EventsPericardial Effusion

Pericardial effusions – 47% of total device events

• 22 classified as “serious” (4.8% of patients)

• 7 required surgical intervention: extended hospitalization by 6 days

• 15 treated percutaneously: extended hospitalization by 4 days

• None resulted in death

3000838-69

Against this background of improving results of LAA

occlusion compared with control warfarin, and because of

initial concerns about trial design and endpoint definition, the

U.S. Food and Drug Administration requested this second trial

(PREVAIL).

A Bayesian analysis design was agreed upon using priors from

PROTECT AF and CAP.

Trial design included a higher risk group, which was achieved

in that PREVAIL patients were older and had higher CHADS2

and CHA2DS2VASc scores.

2/8/2015 28

Procedure /device related events declined significantly

(increasing experience).

Procedural success and complication rates continued to be low

even among new centers and new operators (initial experience

could be successfully transferred to new sites and operators).

2/8/2015 29

The rate of stroke or SE with warfarin was significantly less

than in other contemporary trials of stroke prevention in AF

that had included a warfarin control

TTR is high

Small sample size

2/8/2015 30

TRIAL NAME WARFARIN

GROUP

STROKE

RATES(100 Pt

yrs)

TIME IN

THERAPEUTIC

RANGE

SAMPLE SIZE

RELY

(DABIGATRAN)

1.7 64% 17,000

ARISTOTLE

(APIXABAN)

1.6 62% 16,000

ROCKET AF

(RIVAROXABAN)

2.2 55% 19,000

2/8/2015 31

STUDY LIMITATIONS.

Long term anticoagulation profile pts needed

safety and efficacy in patients in whom anticoagulation is

either relatively or absolutely contraindicated.

Comparison with NOACs.

Clinical significance of loss of mechanical function of

device.

Low sample size for noninferiority

2/8/2015 32

CONCLUSIONS

In this trial, LAA occlusion was noninferior to warfarin for

ischemic stroke prevention or SE >7 days’ post-procedure.

Although noninferiority was not achieved for overall efficacy,

event rates were low,comparable in both arms.

Procedural safety has significantly improved.

LAA occlusion is a reasonable alternative to warfarin therapy

for stroke prevention in patients with NVAF who do not have an

absolute contraindication to short-term warfarin therapy.

(J Am Coll Cardiol 2014;64:1–12).2/8/2015 33

..\..\Documents\2012 Watchman Full animation

IPAD.mp4..

\..\Documents\Left Atrial Appendage Closure with

the WATCHMAN™ Device.mp4

..\..\Documents\LARIAT Animation -

Arrhythmia.org.mp4

Amplatzer Cardiac Plug.mp4.mp4

2/8/2015 34

Study of Left Atrial Appendage Closure in

Patients With Atrial Fibrillation - III (PLACE III)

LARIAT device is FDA approved

2/8/2015 35

2/8/2015 36