R&M Wall SystemsWe differentiate between two different types of wall systems. In order to satisfy allthe possible demands in the field of internal furnishings, several categories of thesewall types are available, which can be configurated as single walls, double walls ormultilayer walls. Each wall category has its application purpose and aim in orderto precisely perform its task in the completion of the interior.
wall systems_2010.qxp:wall systems_2010 26.05.2010 8:29 Uhr Seite 1
Sandwich wall 25 – SW25W
all Systems
06_10 engl.
The SW25 sandwich wall is an alternative solution to the standard wall in situations where space and weight play importantroles. It also has the B-15 fire classification. The assembly is based on the tongue and groove principle. The wall is connectedto the floor using prefabricated U-shaped sections, available in a number of different lengths from the manufacturer. Thesections are laid out and fastened onto the floor.A large variety of surface finishes are available; all of them have a removable protective foil to prevent any damage from occurring during installation. The design of the SW25 wall panel system and all components used have been tested and approved according to international standards.
Sandwich wall 25 – SW25 with supplements
Sandwich wall 25 – SW25
Similar to image
Similar to image
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:04 Uhr Seite 9
Sandwich wall 25 – SW25W
all S
yste
ms
06_10 engl.
Sandwich wall 25 – SW25
Technical data Steel | Steel Steel | Aluminum Aluminum |
or or Aluminum
Stainless steel | Stainless steel Stainless steel | Aluminum
Fire classification B-15 B-0 C
(higher rating in progress)
Sound reduction according 29 dB --- 24 dB
to DIN EN ISO 140-3
Element width 250 – 650 mm 250 – 600 mm 250 – 650 mm
Element length 1000 – 2475 mm 1000 – 2475 mm 1000 – 2475 mm
Thickness 25 mm 25 mm 25 mm
Mass per area – panel 16.5 kg/m² 13.3 kg/m² 9.0 kg/m²
Mass per length – U-profile (steel) 0.6 kg/m 0.6 kg/m 0.6 kg/m
Density of insulation material 150 kg/m3 150 kg/m3 150 kg/m3
(panel and tongue)
Coating PVC foil PVC foil PVC foil
varnish coated varnish coated varnish coated
(others on request) (others on request) (others on request)
Certification EC,USCG,ABS,RMSR EC,USCG n/a
Sandwich wall 25 – SW25
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:04 Uhr Seite 10
Double sandwich wall 25 – SW25W
all Systems
06_10 engl.
Besides the SW25 single walls, the R&M product range offers SW25 double walls as well. According to customer requirements, the double walls can be produced with steel or lightweight aluminum layers. Both variants are B-15 and B-30 fire rated, respectively. With a mass of only 20.6 kg/m², the aluminum version is especially used when the weight on boardplays an important role. If the 50 mm air gap between the walls is filled with low density insulation, the sound reduction can be increased up to 42 dB. Like for the SW25 single walls, the connection of the panels is based on the tongueand groove principle. The connection to the floor is achieved by assembling prefabricated U-profiles that are fastened to thebottom construction.A large variety of surface finishes are available; all of them have a removable protective foil to prevent any damage from occurring during installation. The design of the SW25 double wall panel system and all components used have been testedand approved according to international standards.
Double sandwich wall 25 – SW25
Double sandwich wall 25 – SW25 with supplements
Similar to image
Similar to image
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:05 Uhr Seite 11
Double sandwich wall 25 – SW25W
all S
yste
ms
06_10 engl.
Double sandwich wall 25 – SW25 with 50 mm air gap
Technical data Steel | Steel Aluminum |
or Aluminum
Stainless steel | Stainless steel
Fire classification B-15 B-30
Sound reduction according 38 dB 32 dB
to DIN EN ISO 140-3 (42 dB with filled air gap)
Element width 250 – 650 mm 250 – 650 mm
Element length 1000 – 2475 mm 1000 – 2475 mm
Thickness per panel 25 mm 25 mm
Gap between panels 50 mm 50 mm
Mass per area – panel 33.0 kg/m² 20.6 kg/m²
Mass per length – U-profile 1.2 kg/m 1.2 kg/m
Density of insulation material 150 kg/m3 150 kg/m3
(panel and tongue)
Coating PVC foil PVC foil
varnish coated varnish coated
(others on request) (others on request)
Certification EC,USCG, ABS, RMRS EC, USCG
Double sandwich wall 25 – SW25
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:05 Uhr Seite 12
Sandwich wall 25 – SW25NFW
all Systems
06_10 engl.
The SW25NF wall panel system is a sandwich construction that combines a B-15 fire classification with a low weight. Byusing the tongue and groove principle with an integrated tongue on one panel side, the SW25NF wall panel reaches a massof only 15.6 kg/m² without losing structural integrity. The connection to the floor is achieved by assembling prefabricated U-profiles that are fastened to the bottom construction.A large variety of surface finishes are available; all of them have a removable protective foil to prevent any damage from occurring during installation. The design of the SW25NF wall panel system and all components used have been tested andapproved according to international standards.
Sandwich wall 25 – SW25NF
Sandwich wall 25 – SW25NF with supplements
Similar to image
Similar to image
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:05 Uhr Seite 13
Sandwich wall 25 – SW25NFW
all S
yste
ms
06_10 engl.
Sandwich wall 25 – SW25NF
Technical data Steel | Steel Steel | Aluminum Aluminum |
or or Aluminum
Stainless steel | Stainless steel Stainless steel | Aluminum
Fire classification B-15 B-0 C
(higher rating in progress)
Sound reduction according 30 dB --- ---
to DIN EN ISO 140-3
Element width 250 – 650 mm 250 – 650 mm 250 – 650 mm
Element length 1000 – 2475 mm 1000 – 2475 mm 1000 – 2475 mm
Thickness 25 mm 25 mm 25 mm
Mass per area – panel 15.6 kg/m² 12.0 kg/m² 8.2 kg/m²
Mass per length – U-profile (steel) 0.6 kg/m 0.6 kg/m 0.6 kg/m
Density of insulation material 150 kg/m3 150 kg/m3 150 kg/m3
(panel and tongue)
Coating PVC foil PVC foil PVC foil
varnish coated varnish coated varnish coated
(others on request) (others on request) (others on request)
Certification EC,USCG, RMRS EC,USCG n/a
Sandwich wall 25 – SW25NF (single walls)
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:06 Uhr Seite 14
Double sandwich wall 25 – SW25NFPW
all Systems
06_10 engl.
The SW25NFP double sandwich wall has been developed to meet very stringent noise-insulation requirements when two adjacent compartments need to be separated. By perforating the backsides of each panel, the double wall reaches a soundreduction of 45 dB and a B-30 fire classification status. Like the SW25NF wall panel, the SW25NFP system is based on the tongue and groove connection principle. The connection to the floor is achieved by assembling prefabricated U-profiles thatare fastened to the bottom construction. A large variety of surface finishes are available; all of them have a removable protective foil to prevent any damage from occurring during installation. The design of the SW25NFP double wall panel system and all components used have been tested and approved according to international standards.
Double sandwich wall 25 – SW25NFP
Double sandwich wall 25 – SW25NFP with supplements
Similar to image
Similar to image
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:06 Uhr Seite 15
Double sandwich wall 25 – SW25NFPW
all S
yste
ms
06_10 engl.
Double sandwich wall 25 – SW25NFP with 20 mm air gap
Technical data Steel | Steel
or
Stainless steel | Stainless steel
Fire classification B-30
Sound reduction according to DIN EN ISO 140-3 45 dB
Element width 250 – 600 mm
Element length 1000 – 2475 mm
Thickness per panel 25 mm
Gap between panels 20 mm
Mass per area – panel 26.1 kg/m²
Mass per length – U-profile 1.2 kg/m
Density of insulation material 150 kg/m3
Coating PVC foil
varnish coated
(others on request)
Certification EC, USCG
Double sandwich wall 25 – SW25NFP
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:06 Uhr Seite 16
Standard corner panels – SW25/SW25NFW
all Systems
06_10 engl.
Standard corner panel – SW25 Standard corner panel – SW25NF
Standard corner panel – SW25 Standard corner panel – SW25NF
The 25 mm-thick corner panels can be fitted into the wall panels SW25 and SW25NF to form a flush connection. This ensures an excellent finish, especially in areas with high aesthetic requirements, as there is no joint where the two panels meet.In addition to the standard dimensions of 150 mm per side and an angle of 90°, other dimensions and angles can be produced on request. A large variety of surface finishes are available; all of them have a removable protective foil to prevent any damage from occurring during installation. The design of the standard corner panels for the SW25 and SW25NF sandwich and all compo-nents used have been tested and approved according to international standards.
Similar to imageSimilar to image
Similar to imageSimilar to image
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:06 Uhr Seite 17
Standard corner panels – SW25/SW25NFW
all S
yste
ms
06_10 engl.
Technical data Steel | Steel Aluminum |
or Aluminum
Stainless steel | Stainless steel
Fire classification B-15 C
(higher rating in progress)
Element width – side a 150 mm 150 mm
other sizes according to other sizes according to
customer specification customer specification
Element width – side b 150 mm 150 mm
other sizes according to other sizes according to
customer specification customer specification
Element length 1000 – 2475 mm 1000 – 2475 mm
Angle between sides 90° 90°
other angles according to other angles according to
customer specification customer specification
Thickness 25 mm 25 mm
Density of insulation material 150 kg/m3 150 kg/m3
Coating PVC foil PVC foil
varnish coated varnish coated
(others on request) (others on request)
Certification EC,USCG, ABS, RMRS n/a
Standard corner panels – SW25/SW25NF
Standard corner panel – SW25 Standard corner panel – SW25NF
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:06 Uhr Seite 18
Sandwich wall 50 – SW50W
all Systems
06_10 engl.
The SW50 sandwich wall represents the standard wall model. With a B-15 fire classification and a sound reduction index ofRw = 30 dB, this wall meets all requirements of a modern partition wall system. Its properties include optimum strength,achieved through its high-strength sandwich construction. The assembly is based on the tongue and groove principle. The wallis connected to the floor using prefabricated U-shaped sections, available in a number of different lengths from the manufacturer. The sections are laid out and fastened onto the floor. A large variety of surface finishes are available; all of them have a removable protective foil to prevent any damage from occurring during installation. The design of the SW50 wall panel system and all components used have been tested and approved according to international standards.
Sandwich wall 50 – SW50 with supplements
Sandwich wall 50 – SW50
Similar to image
Similar to image
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:06 Uhr Seite 19
Sandwich wall 50 – SW50W
all S
yste
ms
06_10 engl.
Sandwich wall 50 – SW50
Technical data Steel | Steel Aluminum |
or Aluminum
Stainless steel | Stainless steel
Fire classification B-15 B-15
Sound reduction according 30 dB ---
to DIN EN ISO 140-3
Element width 250 – 800 mm 250 – 600 mm
Element length 1000 – 2475 mm 1000 – 2475 mm
Thickness 50 mm 50 mm
Mass per area – panel 21.1 kg/m² 13.9 kg/m²
Mass per length – U-profile 0.8 kg/m 0.8 kg/m
Density of insulation material 150 kg/m3 150 kg/m3
(panel and tongue)
Coating PVC foil PVC foil
varnish coated varnish coated
(others on request) (others on request)
Certification EC,USCG, RMRS EC, USCG
Sandwich wall 50 – SW50
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:07 Uhr Seite 20
Sandwich wall 50 – SW50NFW
all Systems
06_10 engl.
If a 50 mm wall is required to have a B-15 fire rating in connection with a low weight, the SW50NF wall panel is the bestchoice. By using the connection principle with the integrated tongue, the panel achieves a mass of only 19.3 kg/m².The connection to the floor is achieved by assembling prefabricated U-profiles that are fastened to the bottom construction.A large variety of surface finishes are available; all of them have a removable protective foil to prevent any damage from occurring during installation. The design of the SW50NF wall panel system and all components used have been tested andapproved according to international standard.
Sandwich wall 50 – SW50NF
Sandwich wall 50 – SW50NF with supplements
Similar to image
Similar to image
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:07 Uhr Seite 21
Sandwich wall 50 – SW50NFW
all S
yste
ms
06_10 engl.
Sandwich wall 50 – SW50NF
Technical data Steel | Steel Aluminum |
or Aluminum
Stainless steel | Stainless steel
Fire classification B-15 C
(higher rating in progress)
Sound reduction according 30 dB ---
to DIN EN ISO 140-3
Element width 250 – 550 mm 250 – 650 mm
Element length 1000 – 2475 mm 1000 – 2475 mm
Thickness 50 mm 50 mm
Mass per area – panel 19.3 kg/m² 11.9 kg/m²
Mass per length – U-profile (steel) 0.8 kg/m 0.8 kg/m
Density of insulation material 150 kg/m3 150 kg/m3
Coating PVC foil PVC foil
varnish coated varnish coated
(others on request) (others on request)
Certification EC,USCG, RMRS n/a
Sandwich wall 50 – SW50NF
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:07 Uhr Seite 22
Standard corner panels – SW50/SW50NFW
all Systems
06_10 engl.
The 50 mm-thick corner panels can be fitted into the wall panels SW50 and SW50NF to form a flush connection. This ensures an excellent finish, especially in areas with high aesthetic requirements, as there is no joint where the two panels meet.In addition to the standard dimensions of 150 mm per side and an angle of 90°, other dimensions and angles can be produced on request. A large variety of surface finishes are available; all of them have a removable protective foil to prevent any damage from occurring during installation. The design of the standard corner panel for the SW50 and SW50NF walls and all componentsused have been tested and approved according to international standard.
Standard corner panel – SW50 Standard corner panel – SW50NF
Standard corner panel – SW50 Standard corner panel – SW50NF
Similar to imageSimilar to image
Similar to imageSimilar to image
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:08 Uhr Seite 23
Standard corner panels – SW50/SW50NFW
all S
yste
ms
06_10 engl.
Technical data Steel | Steel Aluminum |
or Aluminum
Stainless steel | Stainless steel
Fire classification B-15 B-151 / C
Element width – side a 150 mm 150 mm
other sizes according to other sizes according to
customer specification customer specification
Element width – side b 150 mm 150 mm
other sizes according to other sizes according to
customer specification customer specification
Element length 1000 – 2475 mm 1000 – 2475 mm
Angle between sides 90° 90°
other angles according to other angles according to
customer specification customer specification
Thickness 50 mm 50 mm
Density of insulation material 150 kg/m3 150 kg/m3
(panel and tongue)
Coating PVC foil PVC foil
varnish coated varnish coated
(others on request) (others on request)
Certification EC,USCG, RMRS EC,USCG
1 Valid only for the standard corner panel – SW50.
Standard corner panels – SW50/SW50NF
Standard corner panel – SW50 Standard corner panel – SW50NF
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:09 Uhr Seite 24
Multilayer wall – MSW50-ZW
all Systems
06_10 engl.
The MSW50-Z multilayer wall is designed to meet stringent noise-insulation requirements. In addition, this wall fulfills the requirements of fire classification B-15. The assembly is based on the tongue and groove principle. The wall is connected tothe floor using prefabricated U-shaped sections, available in a number of different lengths from the manufacturer. The sections are laid out and fastened onto the floor.A large variety of surface finishes are available; all of them have a removable protective foil to prevent any damage from occurring during installation. The design of the MSW50-Z multilayer wall and all components used have been tested and approved according to international standards.
Multilayer wall – MSW50-Z with supplements
Multilayer wall – MSW50-Z
Similar to image
Similar to image
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:09 Uhr Seite 25
Multilayer wall – MSW50-ZW
all S
yste
ms
06_10 engl.
Multilayer wall – MSW50-Z
Technical data Steel | Steel
or
Stainless steel | Stainless steel
Fire classification B-15
Sound reduction according 40 dB
to DIN EN ISO 140-3
Element width 250 – 600 mm
Element length 1000 – 2475 mm
Thickness 50 mm
Mass per area – panel 20.7 kg/m²
Mass per length – U-profile 0.8 kg/m
Density of insulation material – panel 200 kg/m3 / 300 kg/m3
Density of insulation material – tongue 150 kg/m3
Coating PVC foil
varnish coated
(others on request)
Certification EC,USCG
Multilayer wall – MSW50-Z
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:09 Uhr Seite 26
Multilayer wall – MSW50-MW
all Systems
06_10 engl.
The MSW50-M multilayer wall is designed to meet very stringent noise-insulation requirements. With its sound reductionindex of Rw = 42 dB, this wall meets the highest requirements for noise control; in addition, it fulfills the requirements of fire classification B-15. The assembly is based on the tongue and groove principle. The wall is connected to the floor using prefabricated U-shaped sections, available in a number of different lengths from the manufacturer. The sections are laid outand fastened onto the floor.A large variety of surface finishes are available; all of them have a removable protective foil to prevent any damage from occurring during installation. The design of the MSW50-M multilayer wall and all components used have been tested and approved according to international standards.
Multilayer wall – MSW50-M with supplements
Multilayer wall – MSW50-M
Similar to image
Similar to image
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:09 Uhr Seite 27
Multilayer wall – MSW50-MW
all S
yste
ms
06_10 engl.
Multilayer wall – MSW50-M
Technical data Steel | Steel
or
Stainless steel | Stainless steel
Fire classification B-15
Sound reduction according 42 dB
to DIN EN ISO 140-3
Element width 250 – 600 mm
Element length 1000 – 2475 mm
Thickness 50 mm
Mass per area – panel 30.9 kg/m²
Mass per length – U-profile 0.8 kg/m
Density of insulation material – panel 300 kg/m3
Density of insulation material – tongue 150 kg/m3
Coating PVC foil
varnish coated
(others on request)
Certification EC,USCG
Multilayer wall – MSW50-M
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:09 Uhr Seite 28
Bulkhead A-60 – M1000W
all Systems
06_10 engl.
The M1000 bulkhead is a construction for high demands on the passive fire protection on board ships. It replaces heavy non-bearing steel bulkheads with conservative insulations. Moreover, it realizes a reduction in mass, because the weight per unitarea of this wall is much lower than the traditional steel work. An additional lining is not necessary, because both sides of thebulkhead can be covered with a decorative finish.A large variety of surface finishes are available; all of them have a removable protective foil to prevent any damage from occurring during installation. The design of the M1000 bulkhead and all components used have been tested and approvedaccording to international standards.
Bulkhead A-60 – M1000 with supplements
Bulkhead A-60 – M1000
Similar to image
Similar to image
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:10 Uhr Seite 31
Bulkhead A-60 – M1000W
all S
yste
ms
06_10 engl.
Technical data Steel | Steel
or
Stainless steel | Stainless steel
Fire classification A-60
Sound reduction according ---
to DIN EN ISO 140-3
Element width 250 – 650 mm
Element length 1000 – 2440 mm
Thickness 85 mm
Mass per area 32.0 kg/m²
Density of insulation material 128 kg/m3 / 150 kg/m3
Coating PVC foil
varnish coated
(others on request)
Certification EC,USCG, ABS
Bulkhead A-60 – M1000
Bulkhead A-60 – M1000
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:10 Uhr Seite 32
Assembly panelW
all Systems
06_10 engl.
The assembly panel is used in areas where additional outfitting or technical components are placed behind the wall. With itsB-15 fire rating, the assembly panel can be installed wherever a continuous B-15 fire protection needs to be accomplished. By using different locking hooks, the panel can be easily incorporated into 25mm and 50mm wall constructions with a separated or integrated tongue. Just as for the wall panels, the connection to the floor is achieved by assembling prefabricated U-profiles that are fastened onto the bottom construction. A large variety of surface finishes are available; all of them have a removable protective foil to prevent any damage from occurring during installation. The design of the assembly panel and all components used have been tested and approved according to international standards.
Assembly panel
Assembly panel
Similar to image
Similar to image
wall systems_2010.qxp:wall systems_2010 02.06.2010 19:10 Uhr Seite 33
Assembly panelW
all S
yste
ms
06_10 engl.
Technical data Steel | Steel
or
Stainless steel | Stainless steel
Fire classification B-15
Sound reduction according ---
to DIN EN ISO 140-3
Element width 250 – 600 mm
Element length 1000 – 2550 mm
Thickness 25 mm
Mass per area – panel 16.3 kg/m²
Mass per area – U-profile 0.6 kg/m²
Density of insulation material 150 kg/m3
Coating PVC foil
varnish coated
(others on request)
Certification EC,USCG, RMRS
Assembly panel