The Carotid ChallengeThe Carotid Challenge
W e
m
a k
e i d
e a
s c
o m
e a l i v
e
Inva
tec
Wo
rksh
op
– L
anza
rote
, MA
RC
H 2
3rd 2
007
Why making a choice –
why compromises?
The solution is:
W e
m
a k
e i d
e a
s c
o m
e a l i v
e
Inva
tec
Wo
rksh
op
– L
anza
rote
, MA
RC
H 2
3rd 2
007
Closed cell design
Open Cell design
versus
The Dilemma!The Dilemma!
What is better closed or open cell design? What is better closed or open cell design?
W e
m
a k
e i d
e a
s c
o m
e a l i v
e
Inva
tec
Wo
rksh
op
– L
anza
rote
, MA
RC
H 2
3rd 2
007
white black
It is a similar decision like…It is a similar decision like…
versus
W e
m
a k
e i d
e a
s c
o m
e a l i v
e
Inva
tec
Wo
rksh
op
– L
anza
rote
, MA
RC
H 2
3rd 2
007
white black “In medio stat
virtus”
The Answer:The Answer:
BOTH !
W e
m
a k
e i d
e a
s c
o m
e a l i v
e
Inva
tec
Wo
rksh
op
– L
anza
rote
, MA
RC
H 2
3rd 2
007
Fo
r In
tern
al U
se O
nly
Carotid Self-expanding Carotid Self-expanding Stent System Stent System
W e
m
a k
e i d
e a
s c
o m
e a l i v
e
Inva
tec
Wo
rksh
op
– L
anza
rote
, MA
RC
H 2
3rd 2
007
Fo
r In
tern
al U
se O
nly
Hybrid-stent design: Why?
Open-cell stents provide better conformability to
the arterial wall and a more “elegant”
angiographic result
Closed-cell stents provide better embolic protection.
W e
m
a k
e i d
e a
s c
o m
e a l i v
e
Inva
tec
Wo
rksh
op
– L
anza
rote
, MA
RC
H 2
3rd 2
007
Fo
r In
tern
al U
se O
nly
The Hybrid Stent
open cell design
W e
m
a k
e i d
e a
s c
o m
e a l i v
e
Inva
tec
Wo
rksh
op
– L
anza
rote
, MA
RC
H 2
3rd 2
007
Fo
r In
tern
al U
se O
nly
The Hybrid Stent (cont.)
closed cell design
W e
m
a k
e i d
e a
s c
o m
e a l i v
e
Inva
tec
Wo
rksh
op
– L
anza
rote
, MA
RC
H 2
3rd 2
007
Fo
r In
tern
al U
se O
nly
In Summary
Range of diameterRange of diameter
Range of length Range of length
Usable Catheter length Usable Catheter length
Guide wire compatibilityGuide wire compatibility
Introducer compatibilityIntroducer compatibility
Construction & designConstruction & design
Stent MaterialStent Material
On-stent Tantalum On-stent Tantalum markersmarkers
Cylindrical: 7; 9; 11 mm Cylindrical: 7; 9; 11 mm
Tapered: 6-9; 7-10 mmTapered: 6-9; 7-10 mm
20, 30, 40 mm20, 30, 40 mm
135 cm135 cm
0.014” 0.014”
5F5F
Unique Hybrid Stent Unique Hybrid Stent designdesign
NitinolNitinol
1 @ each end1 @ each end
W e
m
a k
e i d
e a
s c
o m
e a l i v
e
Inva
tec
Wo
rksh
op
– L
anza
rote
, MA
RC
H 2
3rd 2
007
Fo
r In
tern
al U
se O
nly
Unique Hybrid-Stent Design
• The fixation segment: open cells design in the distal and proximal
segment, to enhance the flexibility respect the anatomy.
• The therapeutic/functional segment:The therapeutic/functional segment: closed cells designclosed cells design in the middle part with in the middle part with optimal scaffolding, to obtain the appropriate wall optimal scaffolding, to obtain the appropriate wall coverage and wall support coverage and wall support
prevent plaque prolapse prevent plaque prolapse
W e
m
a k
e i d
e a
s c
o m
e a l i v
e
Inva
tec
Wo
rksh
op
– L
anza
rote
, MA
RC
H 2
3rd 2
007
Fo
r In
tern
al U
se O
nly
Two Tantalum marker:
1.enhanced visibility in follow-up procedures
2.secure mounting of the markers thanks to Laser-welding
3.inside orientation to reduce mechanical stress in the stent
Stent Marker
W e
m
a k
e i d
e a
s c
o m
e a l i v
e
Inva
tec
Wo
rksh
op
– L
anza
rote
, MA
RC
H 2
3rd 2
007
Fo
r In
tern
al U
se O
nly
Product Features
Unique hybrid-stent design
Perfect vessel adaptability
5F RX carotid system
Excellent trackability and flexibility of delivery system
Avoid plaque prolapse
Respect vessel anatomy
Atraumatic access
Manage challenging procedures
W e
m
a k
e i d
e a
s c
o m
e a l i v
e
Inva
tec
Wo
rksh
op
– L
anza
rote
, MA
RC
H 2
3rd 2
007
Fo
r In
tern
al U
se O
nly
The worst case!
X-ray Visibility
W e
m
a k
e i d
e a
s c
o m
e a l i v
e
Inva
tec
Wo
rksh
op
– L
anza
rote
, MA
RC
H 2
3rd 2
007
Fo
r In
tern
al U
se O
nly
The Delivery System
Full length braided sheath design
This reinforcement combines pushability and flexibility to enable easy negotiation in tortuous anatomies without kinking
PTFE coating inside the sheath Reduction of friction between sheath and stent
for a gradual, controlled and safe deployment of the stent in the lesion
W e
m
a k
e i d
e a
s c
o m
e a l i v
e
Inva
tec
Wo
rksh
op
– L
anza
rote
, MA
RC
H 2
3rd 2
007
Fo
r In
tern
al U
se O
nly
Stent Deployment
Smooth, controlled stent deployment to avoid jumping effects
First open cell part will apposition to the vessel wall
Then closed cell part will follow…
W e
m
a k
e i d
e a
s c
o m
e a l i v
e
Inva
tec
Wo
rksh
op
– L
anza
rote
, MA
RC
H 2
3rd 2
007
Fo
r In
tern
al U
se O
nly
The Rapid Exchange Section
0.014” guidewire compatible0.014” guidewire compatible 25 cm long RX section, with 25 cm long RX section, with
5F profile5F profile Usable length 135 cm Usable length 135 cm
W e
m
a k
e i d
e a
s c
o m
e a l i v
e
Inva
tec
Wo
rksh
op
– L
anza
rote
, MA
RC
H 2
3rd 2
007
Fo
r In
tern
al U
se O
nly
The Handle
Ergonomic Intuitive (remove red protection and
pull back) One-hand deployment
W e
m
a k
e i d
e a
s c
o m
e a l i v
e
Inva
tec
Wo
rksh
op
– L
anza
rote
, MA
RC
H 2
3rd 2
007
Fo
r In
tern
al U
se O
nly
Model Mix
DesignStent Ø(mm)
Stent L(mm)
Target-Vessel Ø
(mm)
Cylindrical
7.0 20 - 30 5.0 - 6.5
9.0 30 - 40 6.5 - 8.0
11.0 30 - 40 8.0 - 10.0
Tapered6 - 9 30 - 40 4.5 - 8.0
7 - 10 30 - 40 5.0 - 9.0