mom 4s 190309 - acare.cz · 25030 castel mella (bs) italy sales switzerland invatec innovative...

2
0170293-1 ISO 9001:2000 & EN ISO 13485:2003 Certified 0124 Global Sales & Marketing Ofce Invatec Technology Center GmbH Hungerbüelstrasse 12 8500 Frauenfeld - Switzerland Manufacturer & Global Headquarters Invatec S.p.A. - Via Martiri della Libertà, 7 25030 Roncadelle (BS) - Italy www.invatec.com - [email protected] Sales Italy Invatec Italia s.r.l. Via Oriana Fallaci 38 25030 Castel Mella (BS) Italy Sales Switzerland Invatec Innovative Technologies AG Hungerbüelstrasse 12a 8500 Frauenfeld Switzerland Sales USA Invatec Inc 3101 Emrick Blvd, Suite #113 Bethlehem, PA 18020 USA “Not available for sale in the US” Sales Japan Invatec Japan K.K. Shinjuku Island Tower 5th . 6-5-1 Nishi-shinjuku Shinjuku-ku Tokyo 163-1305 Japan Sales China Invatec Beijing Representative Ofce Room 1901, Tower A, Beijing Global Trade Center No. 36 East Road, Beisanhuan Dongcheng District, Beijing China Sales Taiwan Invatec Taiwan No. 141 6F-4 Sec. 1 Kee Lung Road R.O.C., Taipei Taiwan Distributor Manufacturer Ultra safe and efcient in cerebral embolic protection Under continuous product development program, Invatec reserves the right to modify specications without prior notice. Balloon material Compliant elastomeric rubber Balloon marker distance 6 cm Usable shaft length 95 cm Length of the working channel 104.5 cm Distal shaft prole 5 F Recommended guidewire 0.035” (0.89 mm) Balloon occlusion range Up to 13 mm (CCA prox. balloon) Up to 6 mm (ECA dist. balloon) 1 French (F) = 0.333 mm – 1 inch (“) = 25.4 mm = 2.54 cm – 1 cm = 10 mm Proximal Cerebral Protection Device Ref. N° Minimum Inner diameter sheath size of the working channel MOM0130068X5 8F 0.069“/ 1.76 mm MOM0130069X6 9F 0.083“ / 2.12 mm 1045 mm 950 mm 60 mm Technical specications

Upload: others

Post on 11-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: mom 4s 190309 - acare.cz · 25030 Castel Mella (BS) Italy Sales Switzerland Invatec Innovative Technologies AG Hungerbüelstrasse 12a 8500 Frauenfeld Switzerland Sales USA Invatec

0170293-1

ISO 9001:2000 & EN ISO 13485:2003 Cer t i f ied0124

Global Sales & Marketing Offi ceInvatec Technology Center GmbHHungerbüelstrasse 128500 Frauenfeld - Switzerland

Manufacturer & Global HeadquartersInvatec S.p.A. - Via Martiri della Libertà, 725030 Roncadelle (BS) - Italywww.invatec.com - [email protected]

Sales ItalyInvatec Italia s.r.l.Via Oriana Fallaci 3825030 Castel Mella (BS)Italy

Sales SwitzerlandInvatec Innovative Technologies AGHungerbüelstrasse 12a8500 FrauenfeldSwitzerland

Sales USAInvatec Inc3101 Emrick Blvd, Suite #113Bethlehem, PA 18020USA“Not available for sale in the US”

Sales JapanInvatec Japan K.K.Shinjuku Island Tower 5th fl .6-5-1 Nishi-shinjukuShinjuku-ku Tokyo 163-1305Japan

Sales ChinaInvatec Beijing RepresentativeOffi ce Room 1901, Tower A, Beijing Global Trade CenterNo. 36 East Road, BeisanhuanDongcheng District, BeijingChina

Sales TaiwanInvatec Taiwan No. 141 6F-4 Sec. 1 Kee Lung Road R.O.C.,TaipeiTaiwan

DistributorManufacturer

Ultra safe and effi cientin cerebral embolic protection

Under continuous product development program, Invatec reserves the right to modify specifi cations without prior notice.

Balloon material Compliant elastomeric rubber

Balloon marker distance 6 cm

Usable shaft length 95 cm

Length of the working channel 104.5 cm

Distal shaft profi le 5 F

Recommended guidewire 0.035” (0.89 mm)

Balloon occlusion range Up to 13 mm (CCA prox. balloon) Up to 6 mm (ECA dist. balloon)

1 French (F) = 0.333 mm – 1 inch (“) = 25.4 mm = 2.54 cm – 1 cm = 10 mm

Proximal Cerebral Protection Device

Ref. N° Minimum Inner diameter sheath size of the working channel

MOM0130068X5 8F 0.069“/ 1.76 mm

MOM0130069X6 9F 0.083“ / 2.12 mm

1045 mm

950 mm

60 mm

Technical specifi cations

Page 2: mom 4s 190309 - acare.cz · 25030 Castel Mella (BS) Italy Sales Switzerland Invatec Innovative Technologies AG Hungerbüelstrasse 12a 8500 Frauenfeld Switzerland Sales USA Invatec

Proximal Cerebral Protection Device

Mo.Ma Ultra protects the brain from

embolization, blocking antegrade blood fl ow

from the Common Carotid Artery (CCA) and

retrograde blood fl ow from the External Carotid

Artery (ECA): protection is established even

before the lesion is crossed.

Ultra safe Ultra easy Ultra fast Mo.Ma Ultra

Protect & C

ontrolTreat

The easiest way to achieve full time protection and controlBefore the stent crosses the lesion, the patient is fully protected.

Stagnation of the injected contrast medium at the carotid bifurcation, confi rms the proper Flow Blockage.

Effi cient and secure treatmentThe double occlusion-balloon is like a “builtin” guiding catheter, providing back-up support for successful lesion crossing and accurate stent deployment.

Blood will then be aspirated through the Mo.Ma™ Ultra working channel, until the last syringe is clear of debris.

Two in One: Ultra stable guiding catheter combined with proximal cerebral protection system

All types and sizes of debris will be captured

Capture